Académique Documents
Professionnel Documents
Culture Documents
PRODUCT SPECIFICATION
C2FCP
1.00 (25.40)
0.50 (0.68)
0.087 (0.13)
160 (72.6)
40 (0.7)
Electrical Specifications
Maximum Frequency (GHz)
Velocity (percent)
Impedance (Ohms)
dc Breakdown (volts)
Peak Power Rating (kW)
Inner Conductor dc Resistance ohms/1000 ft (ohms/1000 m)
Outer Conductor dc Resistance ohms/1000 ft (ohms/1000 m)
Jacket Spark (volts RMS)
Capacitance pF/ft (pF/m)
Shielding Effectiveness (dB)
Phase Stability (ppm/C)
16.2
85
50
2500
10.4
0.89 (2.92)
1.71 (5.61)
8000
23.9 (78.4)
>90
<10
Construction Materials
Inner Conductor Material
Dielectric Material
Shield Material
Jacket Material
Dimensions
Diameter Inner Conductor in (mm)
Diameter Dielectric in (mm)
Diameter Braid in (mm)
Diameter Over Jacket in (mm)
0.108 (2.74)
0.285 (7.24)
0.320 (8.13)
0.400 (10.16)
Environmental Specifications
Storage Temperature C (F)
Installation Temperature C (F)
Operating Temperature C (F)
Recommended Use
www.andrew.com
C2FCP
Outdoor
Connectors
Part Number
Connector Type
Special Characteristics
Inner Contact
Attachment
Grade
400PNF-C-CR
N Female
Captivated
Standard
400PNF-BHC
N Female
Captivated
Standard
400PTM-C
TNC Male
Captivated
Standard
400PTR
TNC Male
Solder
Standard
400PDM
Solder
Standard
400PSM-CR
SMA Male
Solder
Plated
400APNM
N Male
Solder
Plated
400APNM-C
N Male
Captivated
Plated
400PDF-PMC
400PDF-BHC-CR
Captivated
Captivated
Plated
Plated
400PBM-CR
BNC Male
Solder
Standard
400PNR-C-CR
N Male
Captivated
Plated
400PDFR-BH
Solder
Plated
400PTM-CR
400PNR-C
TNC Male
N Male
Solder
Captivated
Standard
Plated
400PUM
UHF Male
Solder
Plated
400PNR
N Male
Solder
Plated
400PDF-C
400PNM-C-CR
Captivated
Captivated
Standard
Standard
www.andrew.com
C2FCP
Connector Type
Special Characteristics
Inner Contact
Attachment
Grade
400PDM-C-CR
400APNM-CR
Captivated
Solder
Plated
Plated
Cable Lengths
Part Number
Description
Order Length
C2FCP-500KT
C2FCP-1000KT
Standard
Standard
500 FT Reel
1000 FT Reel
www.andrew.com
C2FCP
Attenuation
(dB/100 ft)
Attenuation
(dB/100 m)
Average Power
(kW)
30
50
150
220
450
900
1500
1800
2000
2500
3000
0.76
0.97
1.5
1.9
2.7
3.9
5.1
5.6
5.9
6.7
7.5
2.5
3.2
5
6
8.8
12.7
16.7
18.4
19.4
22
25
2.9
2.3
1.5
1.2
0.83
0.58
0.43
0.4
0.37
0.33
0.29
Standard Conditions:
For Attenuation. VSWR 1.0, ambient temperature 20C (68F).
For Average Power. VSWR 1.0, ambient temperature 40C (104F), inner
conductor temperature 100C (212F); no solar loading.
Customer Support Center:
This Specification Sheet is for reference only and is subject to change without
From North America: 1-800-255-1479 notice.
Copyright 2002 by Andrew Corporation, Printed in U.S.A. 08/15/2005
International: +1-708-873-2307
www.andrew.com