EQ+X---> Max Inter Story Drift

Story

Elevation

Floor Height

Location

X-Dir Max

Y-Dir Max

mm

mm

Drift [ in ratio]

Inter Story

Drift , %

X-Dir Max

TOP

28.210

3.000

Top

26.754

2.389

3.390

FIF

25.210

3.150

Top

23.364

1.989

3.853

FOF

22.060

3.150

Top

19.511

1.597

4.086

THF

18.910

3.150

Top

15.425

1.216

4.114

SF

15.760

3.150

Top

11.311

1.012

3.922

FF

12.610

3.150

Top

7.389

0.899

3.5

GF

9.460

3.500

Top

3.889

0.990

2.748

B1

5.960

2.980

Top

1.141

0.157

0.861

B2

2.980

2.980

Top

0.280

0.054

0.28

Base

0.000

0.000

0.000

H/ 885
H/ 818
H/ 771
H/ 766
H/ 803
H/ 900
H/ 1274
H/ 3461
H/ 10643

0.1130%
0.1223%
0.1297%
0.1306%
0.1245%
0.1111%
0.0785%
0.0289%
0.0094%

EQ+Y---> Max Inter Story Drift


Story

Elevation

Floor Height

Location

X-Dir Max

Y-Dir Max

mm

mm

Inter Story

Drift [ in ratio]

Drift , %

Y-Dir Max

TOP

28.210

3.000

Top

1.302

27.061

3.393

FIF

25.210

3.150

Top

1.019

23.668

3.881

FOF

22.060

3.150

Top

0.749

19.787

4.171

THF

18.910

3.150

Top

0.505

15.616

4.239

SF

15.760

3.150

Top

0.300

11.377

4.060

FF

12.610

3.150

Top

0.236

7.317

3.602

GF

9.460

3.500

Top

0.166

3.715

2.865

B1

5.960

2.980

Top

0.231

0.850

0.601

B2

2.980

2.980

Top

0.044

0.249

0.249

Base

0.000

0.000

0.000

H/ 884
H/ 812
H/ 755
H/ 743
H/ 776
H/ 875
H/ 1222
H/ 4958
H/ 11968

0.1131%
0.1232%
0.1324%
0.1346%
0.1289%
0.1143%
0.0819%
0.0202%
0.0084%

Result
OK for IO
OK for IO
OK for IO
OK for IO
OK for IO
OK for IO
OK for IO
OK for IO
OK for IO

Result
OK for IO
OK for IO
OK for IO
OK for IO
OK for IO
OK for IO
OK for IO
OK for IO
OK for IO

EQ+X---> Inter Story Drift Check for Crack sections


Story

Elevation

Floor Height

Location

X-Dir Max

Y-Dir Max

mm

mm

Drift [ in ratio]

Inter Story

Drift , %

X-Dir Max

TOP

28.210

3.000

Top

34.068

3.635

4.511

FIF

25.210

3.150

Top

29.557

3.111

5.068

FOF

22.060

3.150

Top

24.489

2.480

5.279

THF

18.910

3.150

Top

19.210

1.869

5.244

SF

15.760

3.150

Top

13.966

1.299

4.938

FF

12.610

3.150

Top

9.028

1.010

4.347

GF

9.460

3.500

Top

4.681

1.133

3.365

B1

5.960

2.980

Top

1.316

0.284

1.008

B2

2.980

2.980

Top

0.308

0.073

0.308

Base

0.000

0.000

0.000

H/ 665
H/ 622
H/ 597
H/ 601
H/ 638
H/ 725
H/ 1040
H/ 2956
H/ 9675

0.150%
0.161%
0.168%
0.166%
0.157%
0.138%
0.096%
0.034%
0.010%

EQ+Y---> Inter Story Drift Check for Crack sections


Story

Elevation

Floor Height

Location

X-Dir Max

Y-Dir Max

mm

mm

Drift [ in ratio]

Inter Story

Drift , %

Y-Dir Max

TOP

28.210

3.000

Top

2.101

35.458

4.736

FIF

25.210

3.150

Top

1.689

30.722

5.291

FOF

22.060

3.150

Top

1.254

25.431

5.558

THF

18.910

3.150

Top

0.860

19.873

5.549

SF

15.760

3.150

Top

0.525

14.324

5.230

FF

12.610

3.150

Top

0.270

9.094

4.567

GF

9.460

3.500

Top

0.242

4.527

3.543

B1

5.960

2.980

Top

0.317

0.984

0.714

B2

2.980

2.980

Top

0.061

0.270

0.270

Base

0.000

0.000

0.000

H/ 633
H/ 595
H/ 567
H/ 568
H/ 602
H/ 690
H/ 988
H/ 4174
H/ 11037

Note:

Crack Section used are I22=I33=0.5 for beams, I22=I33=0.7 for Columns & Walls F11=F22= 0.7
It is called that if inelastic drift is within 0.5%, the building should be within Immediate Occupancy use
If inelastic drift is within 1 ~2%, the building should be within Life safety
If inelastic drift is within 2 ~4%, the building should be within Collapse prevention

0.158%
0.168%
0.176%
0.176%
0.166%
0.145%
0.101%
0.024%
0.009%

Result
OK for IO
OK for IO
OK for IO
OK for IO
OK for IO
OK for IO
OK for IO
OK for IO
OK for IO

Result
OK for IO
OK for IO
OK for IO
OK for IO
OK for IO
OK for IO
OK for IO
OK for IO
OK for IO

EQ+X---> Inter Story Drift Check for Maximum Considered Earthquake MCE
Story

Elevation

Floor Height

Location

X-Dir Max

Y-Dir Max

mm

mm

Drift [ in ratio]

Inter Story
X-Dir Max

TOP

28.210

3.000

Top

80.263

7.166

10.172

FIF

25.210

3.150

Top

70.091

5.966

11.558

FOF

22.060

3.150

Top

58.533

4.792

12.259

THF

18.910

3.150

Top

46.274

3.647

12.340

SF

15.760

3.150

Top

33.934

3.036

11.768

FF

12.610

3.150

Top

22.166

2.697

10.499

GF

9.460

3.500

Top

11.667

2.971

8.243

B1

5.960

2.980

Top

3.424

0.472

2.584

B2

2.980

2.980

Top

0.840

0.163

0.840

Base

0.000

0.000

0.000

H/ 295
H/ 273
H/ 257
H/ 255
H/ 268
H/ 300
H/ 425
H/ 1153
H/ 3548

EQ+Y---> Inter Story Drift Check for Maximum Considered Earthquake MCE
Story

Elevation

Floor Height

Location

X-Dir Max

Y-Dir Max

mm

mm

Drift [ in ratio]

Inter Story
Y-Dir Max

TOP

28.210

3.000

Top

3.906

81.184

10.180

FIF

25.210

3.150

Top

3.056

71.004

11.642

FOF

22.060

3.150

Top

2.247

59.362

12.515

THF

18.910

3.150

Top

1.515

46.847

12.717

SF

15.760

3.150

Top

0.900

34.130

12.178

FF

12.610

3.150

Top

0.707

21.952

10.808

GF

9.460

3.500

Top

0.499

11.144

8.594

B1

5.960

2.980

Top

0.693

2.550

1.804

B2

2.980

2.980

Top

0.131

0.746

0.746

Base

0.000

0.000

0.000

Note:

It is called that if inelastic drift is within 0.5%, the building should be within Immediate Occupancy use
If inelastic drift is within 1 ~2%, the building should be within Life safety
If inelastic drift is within 2 ~4%, the building should be within Collapse prevention

H/ 295
H/ 271
H/ 252
H/ 248
H/ 259
H/ 291
H/ 407
H/ 1652
H/ 3995

Drift , %

Result

0.339% OK for IO
0.367% OK for IO
0.389% OK for IO
0.392% OK for IO
0.374% OK for IO
0.333% OK for IO
0.236% OK for IO
0.087% OK for IO
0.028% OK for IO

Drift , %

Result

0.339% OK for IO
0.370% OK for IO
0.397% OK for IO
0.404% OK for IO
0.387% OK for IO
0.343% OK for IO
0.246% OK for IO
0.061% OK for IO
0.025% OK for IO