Vous êtes sur la page 1sur 3

3.

Error Mode
Error
Water
level
sensor
abnormal

Display

Cause/Appearance of Error

Way of Release

IE

If higher than 32kHz or lower than 10kHz of water level


sensor frequency is continuously kept for 4sec in every
0.5sec measurement, this error will occur.
(caused by wire-breaking of water level sensor)

Power Off

tE1

If AD converter data in water temp sensor become larger


than 63,000 (in case of the temp. sensor being open) or less
than 2,000 (in case of the sensor being short-circuited), this
error will occur.

Temperatu
re sensor tE2
abnormal

If AD converter data in fan-housing temp sensor become


larger than 63,000 (in case of the temp. sensor being open)
or less than 2,000 (in case of the sensor being shortcircuited), this error will occur.

tE3

If AD converter data in drying-duct temp sensor become


larger than 63,000 (in case of the temp. sensor being open)
or less than 2,000 (in case of the sensor being shortcircuited), this error will occur.

3E1

In case that position detection signal was not detected longer


than a unit set time during the motor starting and driving, it
will be retried 5 times. If it is not detected more than 6 times,
this error will occur. (caused by wire-breaking of haul-sensor
and motor, or by restriction of motor driving.)

3E2

If an excessive current is detected at IPM, it will be retried 6


times. But if it is detected more than 7 times, this error will
occur.
(caused by short-circuit of motor wire)

3E3

If motor rotates in reverse direction during the motor starting


and driving or abnormal signal is detected at haul sensor, it
will be retried 8 times. But if it is detected more than 9 times,
this error will occur. (caused by motor overload or noise)

3E4

If 8 times retrial of motor positioning is failed during the early


time of motor driving, it will be retried continuously. But if it is
failed more than 32 times, this error will occur. (caused by
wrong connection of haul sensor or motor wire)

PHI

If more than 450V of instant voltage is detected at DC Link,


this error will occur.
(caused by an electric failure during the high-speed
dehydration)
Appearance: IPM Low Arm Short Break

If both AC
power signal
and DC link
voltage are
normal, this

Plo

In case that there is no AC power signal for longer than


60mSec, or that less than 125V of DC Link average
voltage is detected, or that less than 175V is detected
during the PHI error, this error will occur. (caused by
instant electric failure or wire break of power cord)
Appearance: Motor-generating current will be charged
through IPM All Open Break.

error will be
released and
proceed the
previous
operation.

Motor
driving
abnormal

Power
abnormal

- 19 -

Power Off

Start button

Main relay
18E
abnormal

Switch
(button)
abnormal

Unplug the
If AC power signal is detected for longer than 4sec even after
power plug, and
connection of power plug or after opening of the relay by power
PCB needs to
off, this error will occur.
repair.

12E

If power switch is continuously being pressed for 12sec after


power-on, this error will occur.

Power Off

14E

If a button on the control panel is continuously being pressed


for 30sec.

No pressing of a
button longer
than 1sec will
release this error.

If there is no press of any button for 10min after power-on or


8888 changing course before entering an operation, this error will
occur.

Door
abnormal

dE

dE1

If the lock or unlock function of door doesn't work after 3time of


Power Off
trial, this error will occur.

dE2

This error occurs to protect a coil in the locking apparatus


against frequent usage of lock and unlock function of door.

Excessive 0F
water
level/water
leakage
11E
Fan motor
F
abnormal

Water
Drain
abnormal

Close the door


and press
START button
again.

If door is open for longer than 1sec at the time of entering or


during an operation, this error will occur.

Communic
ation
13E
abnormal

Water
Feed
abnormal

Power will be
automatically off
after 5sec.

Automatically
released after
25sec.

If there is no
abnormal
If a communication to MCU on the control panel is abnormal for
communication
longer than 2sec, it functions to reset MCU to 20mSec and to
for longer than
retry the communication. Abnormal communication for longer
1sec, it is
than 6sec will make this error.
automatically
released.
If less than 20.48kHz of frequency of water level sensor is
continuously kept longer than 10sec, this error will occur.
(caused by abnormal increase of water level due to breakdown
Power Off
of feed valve)
Appearance: It functions to operate drain pump to the frequency
level of 23.30kHz in 20sec-On/4sec-Off.
If higher than 24.70kHz of frequency of water level sensor
during washing and rinse, this error will occur.
(caused by water leakage at pump, hose, drum tub, etc.)

Power Off

If excessive current signal due to restriction of fan motor is


detected for longer than 40sec, this error will occur.

Power Off

4E

If the feed water for washing or rinse doesn't reach the terminal
Start button
level of water supply after 20min, this error will occur.

4Ed

If higher than 70C is continuously detected for longer than


8sec at temperature sensor of drying duct during drying, this
error will occur.

EC

If higher than 50C of water temperature is detected at the time


of water feed after selection of WOOL and LINGERIE
Power Off
COURSES, this error functions to prevent damage from such a
high water temperature.

5E

If the water level frequency doesn't reach 24.70kHz after 15min


during the water drain, or if the water level frequency of less
than 23.84kHz is detected for longer than 20sec during
dehydration or drying, this error will occur. (caused by foreign
matters in the drain pump or the breakdown)

- 20 -

Start button

Start button

200If the washing water temperature is increasing more than


HE

Heater
abnormal

Cooling
abnormal

4C every 5sec during the operation of washing heater, this


error will occur. If higher than 100C of the washing water is
detected for longer than 6sec at the temperature sensor, this
error will occur also.
(due to a fire caused by an operation of washing heater
without water)

Open the main


relay at once,
and Power will
be automatically
off after 5sec.

HE1

If the water temperature remains less than 50C for longer


than 10min after the operation of washing heater, or if it
doesn't increase to 2C higher than the initial temperature of
the heater for longer than 8sec, this error will occur. (caused
by breakdown of washing heater or opening of thermostat)

Power Off

HE2

If the fan housing temperature remains less than 35C for


preheat dehydration/low temp drying or less than 50C for
drying of the others, and if it doesn't rise to 5C higher than
the initial temperature of the heater for longer than 8sec, this
error will occur.
(caused by breakdown of drying heater or opening of
thermostat)

Power Off

CE

If the water temperature doesn't fall to lower than 55C for


longer than 30min after the start of washing water cooling,
this error will occur. If the fan housing temp sensor doesn't
Start button
fall to lower than 70C for longer than 30min after the start of
cooling of the last internal temperature for drying.

Unbalance
UE
error

If time sum of retrial for sensing vibration during dehydration


becomes longer than about 10min, this error will occur at
third times after 2-times operation of cloth-untwisting during
water feeding and whirling.

- 21 -

Start button

Vous aimerez peut-être aussi