17.

NC READY LIGHT (green)


This light comes on when the NC system, including the servo unit, is ready for operation.
The light will go out if either of the following situations occurs:
(a) An overtravel limit switch is actuated.
(b) The emergency stop button is pushed.
(c). The machine is in the emergency stop status-(SV alarm, low air pressure, etc.).
After corrective action, the NC READY light will come on-ipgain.
When the NC READY light blinks, the clutch solenoid valve is being energized and neither of
the following operations can be effected. (EXCEPT PEGA KING)
(a) Automatic operation in the TAPE, MEMORY or MDI mode. (However, the PROGRAM
CHECK operation can be effected.)
(b) Punching operation in the MANUAL or MDI mode.
18. TOP DEAD CENTER LIGHT (green)
This light comes on when the crank is at top dead center. During normal operation, the light
will come on after each punch stroke. If the EMERGENCY STOP button (48) is pushed, air
pressure is too low, or there is a fault in the clutch/brake unit, the crank will not stop at top
dead center, the light will remain off, and the machine w/II come to an -emergency stop.
To resume machine operation after the fault is repaired, proceed as follows:
(1) Push the NC POWER OFF button (2) to turn the NC unit OFF.
(2) Turn the MODE switch (43) to MANUAL.
(3) Push the NC POWER ON button (1) to turn the NC unit ON.
(4) Turn the INDEX PIN switch (73) to IN.
(5) Turn the PRESS SELECT,switch (60) to INCHING.
(6) Push the PUNCHING button (61) until the TOP DEAD CENTER -light comes on.
NOTE: When the MODE switch.(43) is turned to TAPE or MEMORY while the light is off,
the machine will come to an emergency stop.
19. X-ORIGIN LIGHT (green)
20. Y-ORIGIN LIGHT (green)
These lights come on when the axes are returned to their origins either by the RETRACT
mode or automatic return command (G50).
These lights will go out if one of the following occurs:
(a) The axes are not at their origings. .
(b) The NCREADY light (17) goes out because of emergency stop.
(c) The PROGRAM CHECK button (45) is turned off after program check.
21. TURRET ORIGIN LIGHT (green)
This light comes on when the turret is returned to its origin by the RETRACT mode. It Gil
go out if the NC READY light (17) goes out.
Except for the above, the light will remain on during operations after the turret has returned
to its origin.
NOTE: When the light is off, automatic operation will not start.