Vous êtes sur la page 1sur 1

Boiler feed water

Hardness as CaCO3
Calcium mg/L as Ca
Chlorides mg/L as Cl
Sulphate mg/L as SO4
Silica mg/L as SiO2
Phosphate as PO4
Iron mg/L as Fe
pH @ 25oC
Total alkalinty as CaCO3
Conductivity S/cm
Total dissolved solids mg/L

0.11
0.01
3.14
0.04
0.02
0.02
0.02
8.35
9.25
8.2
5.24

Before Sand Filter Cooling


( River Water)
Water
Ca hardness as CaCO3
Calcium mg/L as Ca
Chlorides mg/L as Cl
Sulphate mg/L as SO4
Silica mg/L as SiO2
Phosphate as PO4
Iron mg/L as Fe
pH @ 25oC
Total alkalinty as CaCO3
Conductivity us/cm
Total dissolved solids mg/L
Turbidity
Total suspended Solids

4450
426
18440
1986
3.22

4560
438
18626
2032
3.45

98
0.62
7.04
104
48.6
31446
4
0.32

102
0.66
7.21
92
50.1
32716
8
1.12

After Sand Filter:


Turbidity
Total Suspended Solids
pH
Conductivity

2
0.15
6.84
48.6

Vous aimerez peut-être aussi