Académique Documents
Professionnel Documents
Culture Documents
Series 50
KVH-6/2-6-N3-S50
Description of operation
Mounting
example
KVH-6/2-6-N2-S50
P1
P2
YZ
CA D B
5
a
b
P1
Symbol
KVH-6/2-6-N1-S50
CA D B
CA D B
b
P1
b
P2
P1
YZ
YZ
P2
A
a
B
0
Technical data
b
P2
Hydraulic
6
Size
Flow rate
l/min
50
Electrical
Operating
with YZ
bar
315
Supply voltage
12, 24 DC
pressure
without YZ
bar
250
Power
29
-20 to +70
36
mm2/s
15 to 380
Switching frequency
1/h
15000
Ambient temperature
to +50
Coil temperature
to +180
Mounting position
Mass
Filtration
optional
kg
2,7 (N1)
NAS 1638
Duty cycle
C
C
continious
3.35.1
Ordering code
p - Q Performance curves
KVH - 6/2 - 6 -
S50
Symbol
Overlap
Hand operator
Supply voltage
Connector type
Overvoltage protection
Threaded connections
Drainage
Seal type
Nr. units
Special requirementes to be briefly specified
Symbol
a
P1 P2
CA DB
YZ
a
a
YZ
b
P1 P2
N4
25
N3
20
15
N2
10
N1
10
20
30
= no desig.
= AB
Hand operator
without hand operator
with hand operator
= no desig.
=P
Supply voltage
direct voltage 24 V = no desig.
direct voltage 12 V = 12 DC
= no desig.
=G
Threaded connections M / YZ
M18x1,5 (YZ=M14x1,5)
M22x1,5 (YZ=M14x1,5)
G3/8 (YZ=G1/4)
G1/2 (YZ=G1/4)
= no desig.
= YZ
= N1
two units
= N2
three units
= N3
four units
= N4
five units
= N5
15
Threaded connections M
A,B,C,D,P1,P2
LA
Pg9.
37
Threaded connection YZ
B
P2
YZ
29
P1
61
45
92
73
100.4
180
37 0.2
37.5
16
6.8 (z=2)
D
7.5
P1
C
P1
C
P2
D
P1
YZ
P2
YZ
16
YZ
P2
D
64
49 0.2
19
37
88
3.35.2
= no desig.
=L
=K
=M
Overvoltage
Mmax=50Ncm
Flow
( l/min )
one unit
Seal type
= no desig.
NBR seals for mineral oil HL, HLP to DIN 51524
FPM seals for HETG, HEES, HEPG to VDMA 24568 and ISO 15380 = E
Dimensions (mm)
KVH-6/2-6-N3-S50
50
Connector type
Drainage
without YZ
with YZ
= no desig.
= M22
= 3/8
= 1/2
40
Nr. units
Overlap
CA DB
a
N5
30
9
10
11