Vous êtes sur la page 1sur 1

Calculation

sheet
Job Title. PROPOSED RESIDENTIAL HOUSE
IN LORESHO

Job No.
LOR/01/2016

Sheet No.

Rev.

Member/Location
Org. Ref STR 01/02/NRB-LOR/2016
Made by B.O
Date 4/2/16

Chd D.O

BS52683 Compression members


c1.16.3
(a)

Code states: (i) l/r>180: l/b>52


(ii) Effectivelength l = 0.8 x distsnce between nodes.
(iii) c.a < c.adm

BS5268 Rafter maximum force = 9.33kN


Table 9 Try a 150x50mm joist
c=6.8x1.25 = 8.5N/mm
LEX = 0.8 x 785 = 628mm: LEX/rxx LEX/b
LEX/b=628/50= 12.56
E/c= Emin/c= 6000/8.5=706: K12=0.326
c,adm = c x k12 = 8.5x0.326=2.77N/mm
Therefore c,a = 9.334 x10/ (150x50) = 1.245N/mm

BS5268
Table 9

c,a < c,adm: 150x 50mm satisfactory


Tension members
t.adm

150x50mm O.K

t.a
Maximum

tension in internal members is 3.09kN


t.adm=t.a x k3 x k14 = 3.2 x 1.25 x 1.17 = 4.7N/mm
100x50mm
strut maximum force = 3.09kN

Try
Internal
Try a

150x50mm joist
t.a=3.09 x 10/ (100x50) = 0.618N/mm
t.a= t.adm
12.56

LEX/b=628/50=
100x50mm O.K

E/ c=

Deflection of truss

OK in deflection

bA simple empherical formula for deflection of symmetrical flat & pitched


trusses:

L/4290H* (L/26.6 + 1)
where L = span of truss: H = height at midspan
There for = 8.8/(4290x 3.8)* (8.8/26.6 + 1 ) = 0.00632m = 6.32mm
Allowable = 0.003l= 0.003 x 8.8x 10 = 26.4mm
Allowable > actual: satisfactory