Vous êtes sur la page 1sur 12

ELECTRICAL BOQ

PROJECT : ORCHID CROWN TOWER-A


SR NO

DESCRIPTION OF WORK

TYPICAL INTERNAL

A.1

5.0 BHK APARTMENT

A.2

4.0 BHK APARTMENT

TOTAL COST FOR ELECTRICAL WORKS

REV : R2
DATE : 11.02.2016
TOTAL AMOUNT

#VALUE!

#VALUE!

PROJECT :ORCHID CROWN TOWER -A

DATE: 11.02.2016
REV : R2

ELECTRICAL WORKS BOQ -TYPICAL APARTMENT 1 & 3 - 5.0 BHK


ITEM
NO.

DESCRIPTION OF WORK

UNIT

QTY

SUPPLY RATE

INSTALLATION RATE

TOTAL RATE

TOTAL AMOUNT

TYPE -A 5 BHK APARTMENT


1.0

SECTION - 1.0 Distribution board


Supply, installation, testing and commissioning of following
miniature type circuit breaker type boards, wall mounted (flush /
surface) as per drawings and specifications and as required. The
distribution board shall be of sheet steel enclosure with copper
busbars suitable for single phase or three phase MCBs. The MCBDB shall have sheet steel hinged lockable door top to prevent
access to MCBs from outside. The DB shall have suitable neutral
and earth terminal block to facilitate easy termination of wires. All
wires inside the DBs shall be terminated using copper end
terminations. All dbs shall be of double door type, IP 43.

1.1 FLAT DB
Incomer having:

No's

1.00

Nos.

1.00

4 Way VTPN
1NO - 80A, FP, 16kA, MCCB
Outgoing feeders:
1 NO - 63A, 10KA, TP MCB FOR LIGHTIN & POWER.
1 NO - 40A, 10KA, TP MCB FOR AUTOMATION.
1 NO - 40A, 10KA, TP MCB AC ODU.
Add spare in the BOQ
12 WAY ETPN DB
36NOS - 10/16/A SP, 10KA, MCB WITH 3 NOS 32AMPS DPRCCB PER PHASE
AS INCOMER

1.3

Supply, installation, testing and commissioning 32A FP ELMCB,100 mA


with IP-42 type enclosure complete. - For 3Ph AC o/D unit.
SUB TOTAL FOR SECTION

SECTION - 2.0 POINT WIRING


Point wiring shall be done with supply, installation, testing and
commissioning of FRLS category 3 x 1.5 sq mm wires from modular
switches to light and fans outlet in concealed manner including FRLS grade
ISI PVC conduit of 25 mm diameter 1.6-1.8mm (HMS Grade) thickness.
Mains of 2Rx2.5 sqmm + 1Rx1.5 sq mm FRLS wires from D.B. to
switchboard and Switch Board to Switch Board shall be shall be part of
point rate. SITC of switches, sockets, regulators, blank plates, front plates,
2.0 switchboard, PVC conduit and accessories like bends, couplers, deep
junction boxes for lights, zinc passivated 8way MS fan boxes with Hook,
connectors, ferruling, junction boxes, zarri making and semi finishing etc
are part of the point rate. All wire ends shall be lugged properly and
ferruled at both D.B. and S.B. end. All boxes shall be 1.6 mm thick M.S.
boxes zinc passivated for S.B.. All wire sizes unless specified below shall be
as per specifications. Earth wire shall be one size smaller than the phase
wire - limited to min. size of 1.5 sqmm.
Primary light point controlled by switch board with 2runs 2.5sqmm and
2.1 1run 1.5sqmm cu flexible wires in 20mm pvc heavy guage conduit. Refer
enclosed drawings.

Nos.

56.00

Secondary light point control by switch board with 3runs 1.5sqmm cu


flexible wires in 20mm pvc heavy guage conduit. Refer enclosed drawings.

Nos.

2.3

Bell point to be done with 2R x 1.5 sq mm + 1R x 1.0 sqmm wires


including 6 A bell switch & ding dong type bell chime.

Nos.

1.00

2.4

Fan outlet point controlled by one 6 A switch and 5 step 300W electronic
regulator with zinc passivated MS fan boxes with Hook.

Nos.

3.00

Fan outlet point controlled by two nos of 6 A switch two way switches and
2.5 a 5 step 300W electronic regulator with zinc passivated MS fan boxes with
Hook.

Nos.

5.00

6 A x 5 pin 230 Volt socket outlet point controlled by one 6 A switch


located on switch board.

Nos.

8.00

6 A x 230 Volt 5 pin socket outlet point controlled by 6 A switch at


2.80 convenient location including box plate etc complete to be done with 2R x
2.5 sq mm + 1R x 1.5 sqmm wires ckt from D.B.

Nos.

10.00

-do- as above but looped socket point with 2R x 1.5 sq mm + 1R x 1.0


sqmm wires

Nos.

32.00

6 A x 230 Volt 3 pin socket outlet point at convenient location including


2.10 box plate etc complete to be done with 2R x 2.5 sq mm + 1R x 1.5 sqmm
wires considered as secondary

Nos.

16.00

6/16A x 230 Volt 5 pin socket outlet point with 16 A switch with
2.11 Indicator,box and plate complete to be done with 2R x 2.5 sq mm + 1R x
1.5 sqmm wires ckt from D.B.

Nos.

2.00

do as above but looped 6/16A socket to be done with 2R x 2.5 sq mm +


2.12
1R x 1.5 sqmm wires Ckt.

Nos.

4.00

Shaver Socket outlet point with with box and plate complete to be done
2.13
with 2R x 2.5 sq mm + 1R x 1.5 sqmm wires ckt.

Nos.

6.00

AC point to be done with 1 nos 6/16A x 230 Volt 5 pin socket only with box
2.14 and plate complete and 16A DP switch at convinient level with box & plate
complete to be done with 2R x 2.5 sq mm + 1R x 1.5 sqmm wires.

Nos.

7.00

2.2

2.7

2.90

58.00

Point wiring shall be done with supply, installation, testing and


commissioning of FRLS category 3 x 4.0 sq mm wires from modular
switches to POWER SOCKET outlet in concealed manner including FRLS
grade ISI PVC conduit of 25 mm diameter 1.6-1.8mm (HMS Grade)
thickness. Mains of 2Rx4.0 sqmm + 1Rx2.5 sq mm FRLS wires from D.B.
to switchboard shall be part of point rate. SITC of switches, sockets, front
3.00 plates, switchboard, PVC conduit and accessories like bends, couplers,
deep junction boxes for Power circuits, zarri making and semi finishing etc
are part of the point rate. All wire ends shall be lugged properly and
ferruled at both D.B. and S.B. end. All boxes shall be 1.6 mm thick M.S.
boxes zinc passivated for S.B.. All wire sizes unless specified below shall be
as per specifications. Earth wire shall be one size smaller than the phase
wire - limited to min. size of 2.5 sqmm.

PAGE : 2 / 10

6/16A x 230 Volt 5 pin socket outlet point with 16 A switch with Indicator,
3.00 box and plate complete to be done with 2 x 4.0 sq mm + 1 x 2.5 sq.mm
earth wire from D.B. complete.(GEYSER)

Nos.

7.00

2.17

1 no. 6A x 230 Volt 5 pin socket outlet with Box & plate complete near TV
with 1no. 6 A switch with box and plate complete at convinient
location/height to be done with 2R x 1.5 sq mm + 1R x 1.5 sqmm wires ckt
complete.

6.00

2.18

3 nos 6A x 230 Volt 3 pin socket outlet with Box & plate complete near
TV/home theater/set top box with 16 A switch with box and plate complete
at convinient location/height to be done with 2R x 2.5 sq mm + 1R x 1.5
sqmm wires ckt complete.

6.00

Nos.

4.00

Rmt.

435.00

2.19 Fixing of 300/225 mm dia exhaust fan of PVC body with louvers.
MAINS : - from D.B. to D.B. / MCB to outlet / and three phase
sockets if required.
2 x 2.5 sq mm + 1 x 1.5 sq mm FRLS copper flexible wires in and including
2.20.2 25 mm dia rigid PVC conduit of FRLS grade with wall thickness of 1.6-1.8
mm (HMS Grade).
2.20

2.20.3

2 x 4 sq mm + 1 x 2.5 sq mm FRLS copper flexible wires in and including


25 mm dia rigid PVC conduit of FRLS grade with wall thickness of 1.6-1.8
mm (HMS Grade).

Rmt.

285.00

2.20.6

4 x 10 sq mm + 1 x 6.0 sq mm FRLS copper flexible wires in and including


32 mm dia rigid PVC conduit of FRLS grade with wall thickness of 1.6-1.8
mm (HMS Grade).HVAC ODU

Rmt.

60.00

2.20.7

4 x 1.5 sq mm + 1 x 1.5 sq mm FRLS copper flexible wires in and including


25 mm dia rigid PVC conduit of FR grade with wall thickness of 1.6-1.8 mm
(HMS Grade).

Rmt.

SUB TOTAL FOR SECTION

SECTION - 3.0 TELEPHONE / TV DISTRIBUTION


Supply and Laying of 32 mm dia. rigid ISI marked PVC conduit of 1.6-1.8
3.1 mm (HMS Grade) wall thickness with all accessories complete with GI fish
wire.

Rmt.

75.00

Supply and Laying of 25 mm dia. rigid ISI marked PVC conduit of 1.6-1.8
3.2 mm (HMS Grade) wall thickness with all accessories complete with GI fish
wire.

Rmt.

140.00

Supply, Installation testing and commissioning of LVJB of 215 x 215 x


3.5
62mm MS LV junction box for TV, Telephone & Data cables.

Nos.

1.00

Rmt.

152.00

Rmt.

100.00

3.8 Supply, Laying of Cat 6 computer wire in prelaid conduit for data and VDP.

Rmt.

200.00

Supply, Installation testing and commissioning of RJ 11 telephone jack


3.9
type socket with box and plate complete.

Nos.

9.00

Supply, Installation testing and commissioning of T.V. Coaxial outlet with


3.10
box and plate complete.

Nos.

6.00

Nos.

18.00

Nos.

5.00

Supply, Laying of 2 pair 0.5mm dia tinned copper telephone wire in prelaid
3.6
conduit.
3.7 Supply, Laying of RG 6 coaxail wire in prelaid conduit.

Supply, Installation testing and commissioning of RJ 45 computer jack


type socket with box and plate complete.
3.13 1.6 mm thick zinc passivated M.S. boxes for - Wi-Fi
3.13.2 2 Module Box
3.11

SUB TOTAL FOR SECTION

TOTAL for 5.0 BHK APARTMENT-1 & 3


TOTAL NOS. OF APARTMENT-1 & 3

86.00

TOTAL for 5.0 BHK APARTMENT-1 & 3

PAGE : 3 / 10

PROJECT :ORCHID CROWN TOWER -A

DATE: 11.02.2016
REV : R2

ELECTRICAL WORKS BOQ -TYPICAL APARTMENT 2 & 4 - 4.0 BHK


ITEM
NO.

DESCRIPTION OF WORK

UNIT

QTY

SUPPLY RATE

INSTALLATION RATE

TOTAL RATE

TOTAL AMOUNT

TYPE -A 4 BHK APARTMENT


1.0

SECTION - 1.0 Distribution board

Design, supply, installation, testing and commissioning of following


miniature type circuit breaker type boards, wall mounted (flush / surface)
as per drawings and specifications and as required. The distribution
board shall be of sheet steel enclosure with copper busbars suitable for
single phase or three phase MCBs. The MCBDB shall have sheet steel
hinged lockable door top to prevent access to MCBs from outside. The DB
shall have suitable neutral and earth terminal block to facilitate easy
termination of wires. All wires inside the DBs shall be terminated using
copper end terminations. All dbs shall be of double door type, IP 43.
1.1 FLAT DB
Incomer having:

No's

1.00

Nos.

2.00

1NO - 63A, FP, 16kA, MCCB


Outgoing feeders:
1 NO - 40A, 10KA, TP MCB FOR LIGHTIN & POWER.
1 NO - 40A, 10KA, TP MCB FOR AUTOMATION.
1 NO - 32A, 10KA, TP MCB AC ODU.
36NOS - 10/16/A SP, 10KA, MCB WITH 3 NOS 32AMPS DPRCCB PER PHASE AS
INCOMER
1.2

Supply, installation, testing and commissioning 32A FP ELMCB,100 mA with IP-65


type enclosure complete. - For 3Ph AC o/D unit.
SUB TOTAL FOR SECTION

SECTION - 2.0 POINT WIRING


Point wiring shall be done with supply, installation, testing and commissioning of
FRLS category 3 x 1.5 sq mm wires from modular switches to light outlet in
concealed manner including FRLS grade ISI PVC conduit of 25 mm diameter 1.61.8mm (MMS Grade) thickness. Mains of 2Rx2.5 sqmm + 1Rx1.5 sq mm wires
from D.B. to switchboard and Switch Board to Switch Board shall be shall be part of
point rate. SITC of switches, sockets, regulators, blank plates, front plates,
switchboard, PVC conduit and accessories like bends, couplers, deep junction boxes
2.0 for lights, zinc passivated 8way MS fan boxes with Hook, connectors, ferruling,
junction boxes, zarri making and semi finishing etc are part of the point rate. All
wire ends shall be lugged properly and ferruled at both D.B. and S.B. end. All boxes
shall be 1.6 mm thick M.S. boxes zinc passivated for S.B.. All wire sizes unless
specified below shall be as per specifications.Slotted angle cum threaded rods shall
be used for main path of conduiting through corridors which is deemed to be
included in rates quoted. Earth wire shall be one size smaller than the phase wire limited to min. size of 1.5 sqmm.
Primary light point controlled by switch board with 2runs 2.5sqmm and 1run
2.1 1.5sqmm cu flexible wires in 20mm pvc heavy guage conduit. Refer enclosed
drawings.

Nos.

38.00

Secondary light point control by switch board with 3runs 1.5sqmm cu flexible wires
in 20mm pvc heavy guage conduit. Refer enclosed drawings.

Nos.

Primary light point controlled by two way point to be done with 2 nos 6A two way
2.3 switches. 2runs 2.5sqmm and 1run 1.5sqmm cu flexible wires in 20mm pvc heavy
guage conduit. Refer enclosed drawings.

Nos.

RO

2.4

Secondary light point control by two way point to be done with 3runs 1.5sqmm cu
flexible wires in 20mm pvc heavy guage conduit. Refer enclosed drawings.

Nos.

RO

2.5

Bell point to be done with 2R x 1.5 sq mm + 1R x 1.0 sqmm wires including bell
switch & ding dong type bell chime.

Nos.

2.6

Fan outlet point controlled by one 6 A switch and 5 step 300W electronic
regulator with zinc passivated MS fan boxes with Hook.

Nos.

2.2

2.7

2.8

Fan outlet point controlled by two nos of 6 A switch two way switches and a 5 step
300W electronic regulator with zinc passivated MS fan boxes with Hook.
Exhaust fan point controlled by one 6 A switch located at convenient location (on
Lighting SB) and socket outlet at fan end.

1.00

RO

Nos.

Nos.

6 A x 5 pin 230 Volt socket outlet point controlled by one 6 A switch located on
2.9
switch board.

Nos.

6 A x 230 Volt 5 pin socket outlet point controlled by 6 A switch at convenient


2.10 location including box plate etc complete to be done with 2R x 2.5 sq mm + 1R x
1.5 sqmm wires ckt from D.B.

Nos.

2.11

5.00

RO

RO

#VALUE!

5.00

#VALUE!

Nos.

5.00

6/16A x 230 Volt 5 pin socket outlet point with 16 A switch with Indicator,box and
2.12 plate complete to be done with 2R x 2.5 sq mm + 1R x 1.5 sqmm wires ckt from
D.B.

Nos.

2.00

do as above but looped 6/16A socket to be done with 2R x 2.5 sq mm + 1R x 1.5


sqmm wires Ckt.

2.13

-do- as above but looped socket point with 2R x 1.5 sq mm + 1R x 1.0 sqmm wires

34.00

Nos.

4.00

Shaver Socket outlet point with with box and plate complete to be done with 2R x
2.14
2.5 sq mm + 1R x 2.5 sqmm wires ckt.

Nos.

5.00

AC point to be done with 1 nos 6/16A x 230 Volt 5 pin socket only with box and
2.15 plate complete and 16A DP switch at convinient level with box & plate complete to
be done with 2R x 2.5 sq mm + 1R x 1.5 sqmm wires.

Nos.

6.00

6/16A x 230 Volt 5 pin socket outlet point with 16 A switch with Indicator, box and
2.16 plate complete to be done with 2 x 4.0 sq mm + 1 x 2.5 sq.mm earth wire from
D.B. complete.(GEYSER)

Nos.

5.00

5.00

5.00

Nos.

5.00

Rmt.

375.00

1 nos 6A x 230 Volt 5 pin socket outlet with Bos & plate complete near TV with 6
2.17 A switch with box and plate complete at convinient location/height to be done with
2R x 1.5 sq mm + 1R x 1.5 sqmm wires ckt complete.
2.18

3 nos 6A x 230 Volt 5 pin socket outlet with Bos & plate complete near TV/home
theater/set top box with 16 A switch with box and plate complete at convinient
location/height to be done with 2R x 2.5 sq mm + 1R x 1.5 sqmm wires ckt
complete.

2.19 Fixing of 300/225 mm dia exhaust fan of PVC body with louvers.
MAINS : - from D.B. to D.B. / MCB to outlet / and three phase sockets if
required.

2.20

2.20.1

2 x 1.5 sq mm + 1 x 1.5 sq mm FRLS copper flexible wires in and including 25 mm


dia rigid PVC conduit of FR grade with wall thickness of 1.6-1.8 mm (MMS Grade).

PAGE : 2 / 10

2.20.2

2 x 2.5 sq mm + 1 x 1.5 sq mm FRLS copper flexible wires in and including 25 mm


dia rigid PVC conduit of FR grade with wall thickness of 1.6-1.8 mm (MMS Grade).

Rmt.

40.00

2.20.3

2 x 4 sq mm + 1 x 2.5 sq mm FRLS copper flexible wires in and including 25 mm


dia rigid PVC conduit of FR grade with wall thickness of 1.6-1.8 mm (MMS Grade).

Rmt.

20.00

2.20.4

4 x 4 sq mm + 1 x 2.5 sq mm FRLS copper flexible wires in and including 25 mm


dia rigid PVC conduit of FR grade with wall thickness of 1.6-1.8 mm (MMS Grade).

Rmt.

2.20.5

4 x 6 sq mm + 1 x 4.0 sq mm FRLS copper flexible wires in and including 32 mm


dia rigid PVC conduit of FR grade with wall thickness of 1.6-1.8 mm (MMS
Grade).HVAC ODU

Rmt.

30.00

2.20.6

4 x 10 sq mm + 1 x 6.0 sq mm FRLS copper flexible wires in and including 32 mm


dia rigid PVC conduit of FR grade with wall thickness of 1.6-1.8 mm (MMS
Grade).HVAC ODU

Rmt.

20.00

2.20.7

4 x 1.5 sq mm + 1 x 1.5 sq mm FRLS copper flexible wires in and including 25 mm


dia rigid PVC conduit of FR grade with wall thickness of 1.6-1.8 mm (MMS Grade).

Rmt.

160.00

Rmt.
Rmt.

25.00
45.00

2.21
2.21.1
2.21.2

Supply, Laying of following rigid PVC conduit of medium guage with all accessories
complete.
20 MM
25 MM

RO

SUB TOTAL FOR SECTION

#VALUE!

SECTION - 3.0 TELEPHONE / TV DISTRIBUTION


Supply and Laying of 32 mm dia. rigid ISI marked PVC conduit of 1.6-1.8 mm
(MMS Grade) wall thickness with all accessories complete with GI fish wire.

Rmt.

60.00

Supply and Laying of 25 mm dia. rigid ISI marked PVC conduit of 1.6-1.8 mm
3.2
(MMS Grade) wall thickness with all accessories complete with GI fish wire.

Rmt.

130.00

Nos.

1.00

Rmt.

135.00

Rmt.
Rmt.

85.00
185.00

3.1

3.3
3.4
3.5
3.6
3.7

Supply, Installation testing and commissioning of LVJB of 215 x 215 x 62mm MS


LV junction box for TV, Telephone & Data cables.
Supply, Laying of 2 pair 0.5mm dia tinned copper telephone wire in prelaid
conduit.
Supply, Laying of RG 6 coaxail wire in prelaid conduit.
Supply, Laying of Cat 6 computer wire in prelaid conduit for data.
Supply, Installation testing and commissioning of RJ 11 telephone jack type socket
with box and plate complete.

Nos.

8.00

Supply, Installation testing and commissioning of T.V. Coaxial outlet with box and
plate complete.

Nos.

5.00

Supply, Installation testing and commissioning of RJ 45 computer jack type socket


3.9
with box and plate complete.

Nos.

15.00

Rmt.

2.00

3.8

1.6 mm thick zinc passivated M.S. boxes for - TV incomer / call bell / Wi-Fi / VDP
outdoor unit / Curtain point / cable outlet
3.10.1 4 Module Box
3.10

SUB TOTAL FOR SECTION


TOTAL for 4.0 BHK APARTMENT-2 & 4

#VALUE!

TOTAL NOS. OF APARTMENT-2 & 4


TOTAL for 4.0 BHK APARTMENT-2 & 4

100.00
#VALUE!

PAGE : 3 / 10

SUMMARY SHEET FOR DB TO DB /SB TO SB WIRING POINTS IN RUNNING METERS


DB TO DB
4 X 10 Sqmm & 1X 6
Sqmm Wire

DB TO SB
2 X 2.5 Sqmm & 1X 1.5 2 X 4.0 Sqmm & 1X 2.5
Sqmm Wire
Sqmm Wire

56

240

167

422

278

OINTS IN RUNNING METERS


SB TO SB
2 X 1.5 Sqmm & 1X 1.5 Sqmm 2 X 4 Sqmm & 1X 1.5
Wire
Sqmm Wire

182

111

Sr.No.

From

To

1 VTPN DB (A
12 way TPN DB (Apart-3)
2 VTPN DB (A
Automation Panel
3 VTPN DB (A
ODU
4 R1 12Way TSB-5,6,6B,7,9 (Living & Dining)
5 R2 12Way TSB-33,28A,30,30B,29 (Bed-2)
6 R3 12Way TSB-52,58,60,63,64,65 (Kitchen)
7 R4 12Way TSB-10,10A,11 (Common Toilet)
8 R5 12Way TSB-44,46A,48B,47 (Bed-4)
9 R6 12Way TSB-3A,4 (Private Lobby)
10 R7 12Way TSB-49,49A,50 (Toilet-4)
11 Y1 12Way TSB-12,14A,15,17,17B (Bed-1)
12 Y2 12Way TSB-35,37A,38,39,40B (Bed-3)
13 Y3 12Way TSB-42,41,41A (Toilet-3)
14 Y4 12Way TSB-57,59 (Kitchen)
15 Y5 12Way TSB-61,62 (Kitchen)
16 Y6 12Way TSB-19,18A (Toilet-1)
17 Y7 12Way TSB-66,67,68 (Power For WiFi)
18 B1 12Way TSB-20,22A,23B (M-Bed)
19 B2 12Way TSB-26,26A,25A,25C (M-Toilet)
20 B3 12Way TSB-25,25B,25E (M-Toilet)
21 B4 12Way TSB-73,73A (Servent Room)
22 B5 12Way TSB-74,72,72A,72B (Servent Toilet)
23 B6 12Way TSB-69,70,71 (Power For WiFi)
24 B7 12Way TSB-31,31A,31B,32 (Toilet-2)
Total
10% Extra
Total

Drawing No.
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006

Revision
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1
R1

4 X 10 Sqmm & 1X 6 Sqm


3+3+4
3+3+4
3+18.1+5+

4 X 10 Sqmm & 1X 6 Sqmm Wire

2 X 2.5 Sqmm & 1X 1.5 Sqmm Wire

2 X 4.0 Sqmm & 1X 2.5 Sqmm Wire

10
10
30.6
3+1.4+2.6+

10

3+16.5+3+

25.5

3+2+3

8
3+11.5+2.5

3+3+1+3
3+1.2+4+3

10
11.2
3+6.6+3.5+

3+13+3.1+
3+9+2+3

22.1
17
3+9+2.2+1

3+2.9+1.3+

10.2
3+0.7+3.4+
3+12.5+3.8

3+9+1
3+16.5+2.7

13
25.2
3+19+3.2+

3+19.5+3

25.5

3+3+5.1+3

14.1
3+3+5.1+3

3+16.5+4+

26.5
3+16.6+3

50.6
5.06
56

218.3
21.83
240

2 X 4.0 Sqmm & 1X 2.5 Sqmm Wire

20

16.1

18.8

10.1
22.3

28.2

14.1

22.6
152.2
15.22
167

SB TO SB LIGHTING POWER WIRING MEASUREMENT SHEET


Sr.No.
1

R1 12Way TPN DB (Apart-1)

From

To

SB-5 (Living & Dining)

SB-6B

SB-6B

SB-6

SB-6

SB-7

SB-7

SB-9

Drawing No.
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006

Revi
sion
R1 2 X 2.5 Sqmm & 1X 1.5 Sqmm Wire
R1
R1

Qty

1.8+0.3

R1
R1

R1
R1

2+0.7+0.3

R1

11+4+3+0.3

2 X 4.0 Sqmm & 1X 1.5 Sqmm Wire

Qty

2.1

AC

GY

3
18.3

R1
R2 12Way TPN DB (Apart-1)

SB-33 (Bed-2)

SB-30

DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006

SB-30

SB-30B

DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006

SB-30B

SB-29

DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006

SB-28A

DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006

SB-63

DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006

2
R2 12Way TPN DB (Apart-1)

SB-29

R3 12Way TPN DB (Apart-1)

R1
R1

0.7+2+0.3

R1
R1

1+0.3+0.3

1.6

R1
R1

3.5+1.6+2.3+0.6+0.3

8.3

0.3+2.8+1.5+0.2+0.3

5.1

R1
R1

0.3+0.6+0.3

1.2

R1

0.3+2.2+2.1+0.2+0.3

5.1

0.3+2.4+1.6+2.3+0.6+0.3

7.5

0.3+3.4+0.8+1.5+0.5+0.3

6.8

R1
R1

0.3+2.8+1.5+2.8+0.3

7.7

R1

0.3+2.8+2.4+0.2+0.3

0.3+0.2+2.8+0.6+0.3

4.2

0.3+3+2+2.3+0.6+0.3

8.5

R1
R1

0.3+0.2+1.6+2.8+0.3

5.2

R1

0.3+2.8+1.9+2.8+0.3

8.1

0.3+1.3+0.3

1.9

0.2+0.3+3.5+2.8+0.3

7.1

0.3+2.8+1.2+0.2+0.3

4.8

R1

0.6+1.3+3+0.3

5.2

0.3+2.8+2.5+3+0.3

8.9

0.3+1+0.3

1.6

R1
SB-52 (Kitchen)

R1
R1

SB-64
R3 12Way TPN DB (Apart-1)

SB-64

SB-65

SB-65

SB-58

SB-58

SB-60

DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006

R1
R1
R1
R1
R1
R1

0.3+0.2+0.7+2.2+0.3

3.7

R1

0.3+2.2+2.3+0.8+0.3

5.9

R1
R4 12Way TPN DB (Apart-1)

SB-10 (Common Toilet)


(PW ROOM)

SB-10A

R4 12Way TPN DB (Apart-1)

SB-10A

SB-11

DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006

R1
R5 12Way TPN DB (Apart-1)
5
R5 12Way TPN DB (Apart-1)

SB-44 (Bed-4)

SB-46A

SB-46A

SB-48B

SB-48B

SB-47

DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006

R1
R1

0.3+3.1+0.3

3.7

R1
R1

0.3+2.4+2.6+1.6+2.4+0.3

9.6

R1
R1

R6 12Way TPN DB (Apart-1)

SB-3A(Private Lobby)

SB-4

DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006

R1
R1

R7 12Way TPN DB (Apart-1)


7
R7 12Way TPN DB (Apart-1)

SB-49 (Toilet-4)

SB-49A

SB-49A

SB-50

DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006

R1
Y1 12Way TPN DB (Apart-1)

SB-12 (Bed-1)

SB-14A
SB-17

8
Y1 12Way TPN DB (Apart-1)

SB-14A

SB-15

SB-17

SB-17B

SB-35 (Bed-3)

SB-40B

SB-40B

SB-39

SB-39

SB-38

SB-38

SB-37

DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006

R1
R1

0.3+2.8+4.6+2.8+0.3

R1
R1

0.3+1.4+0.3

10.8
2

0.3+0.6+0.3

1.2

R1
R1

0.3+2.8+1.6+3.4+0.3

8.4

R1
R1

0.3+3.4+1+3+0.3

R1
R1
R1
R1

Y2 12Way TPN DB (Apart-1)

9
Y2 12Way TPN DB (Apart-1)

DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006

R1
R1
R1

0.3+0.6+1.3+3.5+0.3

R1
10

Y3 12Way TPN DB (Apart-1)

SB-42 (Toilet-3)

SB-41

SB-41

SB-41A

DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006

SB-59

DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006

SB-62

DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006

R1
11

Y4 12Way TPN DB (Apart-1)

SB-57 (Kitchen)

R1

0.3+2.7+0.3

3.3

R1
12

Y5 12Way TPN DB (Apart-1)

SB-61 (Kitchen)

R1
R1

13

Y6 12Way TPN DB (Apart-1)

SB-19 (Toilet-1)

SB-18A

DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006

R1
R1

14

Y7 12Way TPN DB (Apart-1)

SB-66 (Power For WiFi)

SB-68

SB-68

SB-67

DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006

R1
R1

0.3+0.2+4.3+0.2+0.3

5.3

R1

0.3+0.2+2.9+0.2+0.3

3.9

R1
R1

0.3+3+0.3

3.6

R1

0.3+2.8+4.5+3.4+0.3

R1
18 B1 12Way TPN DB (Apart-3)

SB-20 (M-Bed)

SB-22A

SB-22A

SB-23B

DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006

SB-26

DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006

11.3

R1
19 B2 12Way TPN DB (Apart-3)

SB-25A (M-Toilet)

R1

R1
B2 12Way TPN DB (Apart-3)

SB-26A
SB-26

SB-25C

DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006

R1
R1

0.3+2.8+2.1+0.2+0.3

5.7

R1

0.2+0.3+0.5+1.8+0.3

3.1

0.3+0.2+1.3+2.8+0.3

4.9

R1
R1

0.3+0.3

0.6

R1

0.3+2.8+2.1+0.2+0.3

5.7

R1
20 B3 12Way TPN DB (Apart-3)

SB-25 (M-Toilet)

SB-25B

SB-25B

SB-25E

DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006

R1
R1

0.3+2.8+2.6+2.8+0.3

R1

0.3+0.3+0.4

8.8
1

R1
21 B4 12Way TPN DB (Apart-3)

SB-73 (Servent Room)

SB-73A

DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006

R1
R1

22 B5 12Way TPN DB (Apart-3)

SB-74 (Servent Toilet)

SB-72A
SB-72
SB-72B

23 B6 12Way TPN DB (Apart-3)

SB-71 (Power For WiFi)

SB-69

SB-69

SB-70

DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006

R1

R1
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006

R1
R1

0.3+0.1+10+0.1+0.3

10.8

R1

0.1+0.3+7+0.1+0.3

7.8

R1
24 B7 12Way TPN DB (Apart-3)

B7 12Way TPN DB (Apart-3)

SB-31,31A,31B,32 (Toilet-2)
SB-31A
SB-31A
SB-32

SB-32
SB-31B

SB-31

SB-32A

DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006

R1
DB/OC/EL/T/A/020
DB/OC/EL/T/A/2/006

R1

0.3+2.8+1.7+0.2+0.3

5.3

Total
10% Extra

165.1
16.51

101.2
10.12

Total

182

111

Vous aimerez peut-être aussi