Vous êtes sur la page 1sur 64

Front cover

This PDF is intended for on-screen viewing. A


PDF formatted for A4-folded-to-A5 booklet printing
is also available from our download centre at
www.siemens.com.au/rail-components.

Rail Automation Short-Form Catalogue


November 2014

TTTNPSFC
Issue 26.0

For More Information


For More Information

Contact Siemens Rail Automation


W: http://www.siemens.com.au/rail-components

Australia
Siemens Rail Automation Pty Ltd
T: +61 1300 724 518

ABN 78 000 102 483

E: rail-components.au@siemens.com

Indonesia
P.T. Siemens Indonesia
T: +62 21 2754 3470

E: warren.matthew@siemens.com

Malaysia
Siemens Malaysia Sdn. Bhd
T: +60 3 7952 5075

E: seatkoh.yiu@siemens.com

New Zealand
Siemens (N.Z.) Limited.

Company Number 318303

T: +64 (0) 9 580 5500

E: rail-components.au@siemens.com

Thailand
Siemens Limited
T: +66 (0) 2 718 2170

E: chakkarin.prinyasart@siemens.com

Download Documents from the Download Centre


(www.siemens.com.au/downloadcentre)
Get a variety of documents, and keep them up-to-date, from the Download Centre. Basic documents
such as datasheets for product overviews or bulletins for adviceare immediately accessible; detailed
documentssuch as instruction sheets for how to procedures, and manuals for product usage and firstline maintenance etcrequire a one-off on-line registration.

Siemens Rail Automation

Short-Form Catalogue

Document CI:

TTTNPSFC

Issue:

26.0

Date of Issue:

November 2014

Copyright
Transmittal, reproduction, dissemination or editing of this document is prohibited. Use of this documents contents and
communication thereof to others without express authorization is also prohibited. Offenders will be held liable for
payment of damages. All rights created by patent grant or registration of a utility model or design patent are reserved.
Siemens Rail Automation Pty Ltd 2014. All rights reserved. ABN 78 000 102 483

CONTENTS
SECTION

PAGE

For More Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

1 Signals
1.1 Colour Light and LED Signals
1.1.1 Complete Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Sigmaguard Style L Signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sigmaguard Style LS Searchlight Replacement Signal . . . . . . . . . . . . . . .
Sigmaguard LED Style U2L Colour Light Signals . . . . . . . . . . . . . . . . . . .
Sigmaguard LED Style Close-up Signals . . . . . . . . . . . . . . . . . . . . . . . . . .

11
11
11
12

1.1.2 Signal Lamps and LED Retrofit Kits . . . . . . . . . . . . . . . . . . . . . . . . . 12

VELCORP/GEMS Long Life Signal Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . 12


Sigmaguard Rear-Access Retrofit Kit for LED Signals . . . . . . . . . . . . . . . . 12

1.2 Subsidiary Signals


Sigmaguard LED Style L Junction Route Indicator . . . . . . . . . . . . . . . . . .
Sigmaguard LED Position Light Junction Indicator, PJ2L . . . . . . . . . . . . .
Sigmaguard LED Style L Position Light Shunt Signal . . . . . . . . . . . . . . . .
Sigmaguard LED Theatre Route Indicator . . . . . . . . . . . . . . . . . . . . . . . .
Sigmaguard LED Banner Repeat Signal . . . . . . . . . . . . . . . . . . . . . . . . . .
Sigmaguard LED Guards Indicator and Retrofit Kits . . . . . . . . . . . . . . . .
Sigmaguard LED Running Turnout Signal . . . . . . . . . . . . . . . . . . . . . . . .
Sigmaguard LED Repeater Signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LED Turnout Repeat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sigmaguard LED Stencil Route Indicator . . . . . . . . . . . . . . . . . . . . . . . . .
Sigmaguard LED Marker Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sigmaguard Specialist LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . .

12
13
13
13
13
14
14
14
14
15
15
15

1.3 Masts and Hardware


Sigmaguard Easy Access Signal Masts . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Sigmaguard Rotatable Top of Post Signal Mount . . . . . . . . . . . . . . . . . . 16

2 Points
2.1 Electric Point Machines
Switchguard One Trough S 700 V Points Operating System . . . . . . . . . .
Switchguard M3A Mk II Electric Point Machine
(Emergency Hand Crank) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Switchguard M23A MkII Electric Point Machine (Dual Control) . . . . . . .
Switchguard Series 84M MkIII Point Machine (Universal) . . . . . . . . . . . .
Switchguard S 700 K Point Machine ...NEW . . . . . . . . . . . . . . . . . . . .
Switchguard SURELOCK ...NEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Clearguard Circuit Controller Retrofit Kit . . . . . . . . . . . . . . . . . . . . . . . . .

17
17
17
17
18
18
18

2.2 Pneumatic Point Controllers


ES Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
A Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Siemens Rail Automation Pty Ltd 2014. All rights reserved.

CONTENTS
SECTION

PAGE

2.3 Point Locks and Detection


Switchguard HLM MkII Series Point Locks with Detector
...Improved . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Switchguard HM MkII Series Point Detectors ...Improved . . . . . . . . .
Circuit Controller Style U5A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Switchguard ELP 319 End Position Detector ...NEW . . . . . . . . . . . . . .

19
19
20
20

2.4 Mechanical Point Equipment


Switchguard T21M Point Machine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Switchguard Derail & Crowder ...Improved . . . . . . . . . . . . . . . . . . . . 21

2.5 Bearers
Switchguard In-Bearer Point Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

3 Relays
Style Q Plug-in Relays Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

3.1 Neutral Line Relays, Non-Immune


Relay Style QN1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Relay Style QNN1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Relay Style QND2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Relay Style QNND1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Relay Style QS2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Relay Style QNM1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Relay Style QNCD1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Relay Style QNCM1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

23
23
23
23
24
24
24
24

3.2 Neutral AC-Immune Line Relays


Relay Style QNA1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Relay Style QNNA1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

3.3 Neutral Slow Acting, AC-Immune Line Relays


Relay Style QSPA1 Slow Operate Track Circuit Relay . . . . . . . . . . . . . . .
Relay Style QSRA1 Slow Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Relay Style QSRA4 Slow Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Relay Style QNNS1 Slow Operate and Release . . . . . . . . . . . . . . . . . . . .

25
25
25
25

3.4 Biased AC-Immune Line Relays


Relay Style QBA1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Relay Style QBBA1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Relay Style QBCA1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

3.5 Magnetic Latched Line Relays


Relay Style QL1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

3.6 Track Relays


Relay Styles QT1 & QT2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Relay Style QTA2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Relay Style QBT1 for Motor Current Proving . . . . . . . . . . . . . . . . . . . . . .
Relay Style QTM1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

26
26
26
26

3.7 Lamp Proving Relays


Relay Style QECX20 LED Lamp Proving . . . . . . . . . . . . . . . . . . . . . . . . . .
Relay Style QN3 Lamp Proving Multilamp circuits . . . . . . . . . . . . . . . . .
Relay Style QEC1 Slow Release Lamp Proving 12V lamps . . . . . . . . . . . .
Relay Style QSR3 Slow Release Lamp Proving . . . . . . . . . . . . . . . . . . . . .
Relay Style QECX5 Slow Release Lamp Proving
110 Vac 18 + 3.5W Twin Filament Lamp . . . . . . . . . . . . . . . . . . . . .

26
27
27
27
27

Siemens Rail Automation Pty Ltd 2014. All rights reserved.

CONTENTS
SECTION

PAGE

Relay Style QECX7 Lamp Proving


10 Vac 18 + 3.5W Twin Filament Lamp . . . . . . . . . . . . . . . . . . . . . .
Relay Style QECX8 Lamp Proving 110 Vac 60W Incandescent . . . . . . . .
Relay Style QUCX1 Lamp Proving 110 Vac JRI . . . . . . . . . . . . . . . . . . . . .
Relay Style QNX1 Lamp Proving 35 W Shunt Signal . . . . . . . . . . . . . . . .
Relay Style QECX 1,11,15 & 19 Lamp Proving
for SL34 or SL35 110 Vac Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . .
Relay Style QEECF1 Lamp Proving 12 V Crossing Signals . . . . . . . . . . . .

27
27
27
27
27
28

3.8 Timers
Timer Style QTD1 Dual Non-Vital . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Timer Style QTD4 Delay to Drop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Timer Style QTD5 Delay to Pick . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Timer Style QCJ1 Non Vital Point Machine . . . . . . . . . . . . . . . . . . . . . . .

28
28
28
28

3.9 Transformer-Rectifier Units


Transformer-Rectifier Style QXR1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

3.10 Special-Purpose Units


Style QR Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Relay Unit Style QAC1 Battery Charge Fail Detector . . . . . . . . . . . . . . . . 29
Relay Unit Style QAJTC1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

3.11 AC Relays
Relay Style QNHX1 Interface to WESTLOCK and SSI . . . . . . . . . . . . . . . . 29
Relay Style QWCX1for Point Machine Motor Proving . . . . . . . . . . . . . . . 29
Relay Style QNHCX1 Interface to WESTLOCK and SSI . . . . . . . . . . . . . . . 29

3.12 Relay Plug Board


Relay Plug Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

5 Train Detection
5.1 Audio Frequency Overlay Track Circuits
Clearguard Intelligent Processor Island Track Circuit (IPITC) . . . . . . . . . .
Clearguard Phase Shift Overlay 4000 (PSO 4000) . . . . . . . . . . . . . . . . . .
Wayguard PSO GCP 4000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Clearguard Series Overlay Circuit Track Circuit (SOTC) . . . . . . . . . . . . . .

31
31
31
31

5.2 Track Feed Sets


Style WA15Q Track Feed Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Style R5-9 AC-Immune Track Feed Set . . . . . . . . . . . . . . . . . . . . . . . . . . .
WESTRAK Track Feed Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WESTRAK Diode Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

32
32
32
32

5.3 Impedance Bonds


High Current Impedance Bonds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

5.4 Accessories
Style TD4 Track Disconnection Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

5.5 Jointless Track Circuit Equipment


Clearguard TCM 100 Track Vacancy Detection System ...NEW . . . . . . 33
Clearguard FS2550 Jointless Track Circuit . . . . . . . . . . . . . . . . . . . . . . . . 33

5.6 Relay Track Circuit


VT1 ac Track Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

5.7 Axle Counters


Clearguard ACM200 Axle Counting System . . . . . . . . . . . . . . . . . . . . . . 34
Clearguard ACM100 Axle Counting System . . . . . . . . . . . . . . . . . . . . . . 34

Short-Form Catalogue Issue 26.0

CONTENTS
SECTION

PAGE

6 Trainstops
6.1 Trainstops (Trip Type)
Trainguard Trainstop, Style JA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Trainguard Trainstop, Style JAH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Trainguard Trainstop Power Unit, Style EH1 . . . . . . . . . . . . . . . . . . . . . .
Clearguard Circuit Controller Retrofit Kit . . . . . . . . . . . . . . . . . . . . . . . . .

35
35
35
35

9 Level Crossing Protection


9.1 Flashing Lights & Accessories
Wayguard Level Crossing Light Crossarms . . . . . . . . . . . . . . . . . . . . . . .
Sigmaguard LED Crossing Signals & Retrofit Kits . . . . . . . . . . . . . . . . . .
Sigmaguard LED Barrier Arm Lights . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wayguard SAFEFLASHLevel Crossing Flasher . . . . . . . . . . . . . . . . . . .
Wayguard SSCC III PlusSolid-State Crossing Controller . . . . . . . . . . . .

37
37
37
37
38

9.2 Barrier Mechanisms


Wayguard Circuit Controller and Motor Retrofit Kits . . . . . . . . . . . . . . . 38
Wayguard S-60 Level Crossing Barrier Mechanism . . . . . . . . . . . . . . . . . 38
Wayguard S-20/S-40 to S-60 Retrofit Kit ...NEW . . . . . . . . . . . . . . . . . 38

9.3 Barrier
Wayguard Level Crossing Barrier Arms . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Wayguard Pre-Dressed Level Crossing Barrier Arms ...NEW . . . . . . . . 39

9.4 Warning Bells


Wayguard Level Crossing BellSolid State . . . . . . . . . . . . . . . . . . . . . . 39

9.5 Grade Crossing Predictors


Wayguard Grade Crossing Predictors4000 Series (GCP 4000) . . . . . .
Wayguard Motion Sensor 4000 (MS 4000) ...NEW . . . . . . . . . . . . . .
Wayguard AccessoriesGrade Crossing Predictors . . . . . . . . . . . . . . . .
Wayguard DC Shunting Enhancer Panel . . . . . . . . . . . . . . . . . . . . . . . . .
Wayguard PSO GCP 4000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

40
40
41
41
42

9.6 Installations
Crossing in a Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

10 Control and Signalling Systems


10.1 Computer-Based Interlockings
Interlocking Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Trackguard WESTRACE MkII Interlockings . . . . . . . . . . . . . . . . . . . . . . . .
Trackguard WESTRACE Object Controllers . . . . . . . . . . . . . . . . . . . . . . .
Trackguard WESTRACE GCSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Trackguard WESTRACE GSIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Controlguide MoviolaW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Trackguard WESTLOCK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Trackguard Solid-State Interlocking (SSI) . . . . . . . . . . . . . . . . . . . . . . . .
Vital Signal Logic Simulator (VSLS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

43
43
43
44
44
44
44
45
45

10.2 Telemetry Systems


Controlguide WESTRONIC S2 (System Two) . . . . . . . . . . . . . . . . . . . . . .
Controlguide WESTRONIC S2 Telemetry Scanner Modules . . . . . . . . . .
Controlguide S2/DIP42 Digital Input Module . . . . . . . . . . . . . . . . . . . . .
Controlguide S2/DIP43 Digital Input Module . . . . . . . . . . . . . . . . . . . . .
Controlguide S2/DOP42 Digital Output Module . . . . . . . . . . . . . . . . . . .

45
45
46
46
46

Siemens Rail Automation Pty Ltd 2014. All rights reserved.

CONTENTS
SECTION

PAGE

Controlguide S2/DOP43 Digital Output Module . . . . . . . . . . . . . . . . . . .


Controlguide S2/ALC Alarm & Line Changeover . . . . . . . . . . . . . . . . . . .
Controlguide WESTRONIC S2/PSU Power Supply Module . . . . . . . . . . . .
Controlguide S2/SLC Serial Line Converter (RS232-RS422) . . . . . . . . . . .
Controlguide S2/VFC45 Voice Frequency Modem CCITT V.23 FSK . . . . .
Vital and Non-Vital Communication Systems . . . . . . . . . . . . . . . . . . . . .
HD/Link System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ethernet Spread-Spectrum Radio (ESSR) . . . . . . . . . . . . . . . . . . . . . . . . .
Wayside Access Gateway (WAG) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CNA2000 Network Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

46
46
46
46
47
47
47
47
47
48

10.3 Train Control Equipment


Controlguide Rail 9000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Controlguide WESTCAD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

10.4 Automatic Train Control and Protection


Trainguard WESTECT II ATP (Automatic Train Protection)
...Improved . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Trainguard ETCS ...NEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Trackguard Train Sentinel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
End of Train Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Head of Train Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

48
49
49
49
50

10.5 Automatic Equipment Identification (AEI) Systems


Transcore Automatic Equipment Identification . . . . . . . . . . . . . . . . . . . .
Trackguard WESTECT Portable Transponder Reader Module (PTRM) . . .
Transcore AI1200 Reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transcore AR2200 RF Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transcore Encompass 4 RFID Tag Reader . . . . . . . . . . . . . . . . . . . . . . . . .
Transcore AA3233-004 Heavy Rail Antenna . . . . . . . . . . . . . . . . . . . . . .
Transcore AA3234 Light Rail Antenna . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transcore AA3110 Parapanel Antenna . . . . . . . . . . . . . . . . . . . . . . . . . .
Transcore AT5118 Rail Harsh Environment Rail Tag . . . . . . . . . . . . . . . .
Transcore AT5413 Hardened Rail Tag . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transcore PT5780 Permissions Tag . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transcore AT5720 Check Tag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transcore AP4118 Rail Tag Programmer . . . . . . . . . . . . . . . . . . . . . . . . .

50
50
50
50
51
51
51
51
52
52
52
52
53

10.6 Fault Monitoring and Data Logging


Wayguard SEAR II Event Analyser and Recorder . . . . . . . . . . . . . . . . . . .
Wayguard SEAR II Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Axle Counter SEAR Island Interface (ACSI) . . . . . . . . . . . . . . . . . . . . . . . .
Wayguard Argus Event Recorder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Condition Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

53
53
53
53
54

10.7 Integrated Communication and Control Systems (ICSS)


Controlguide SystematICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Controlguide SystematICS RailSCADA . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

11 Accessories
11.1 Terminal Blocks
RSA Double-Row Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

Short-Form Catalogue Issue 26.0

CONTENTS
SECTION

PAGE

11.2 Lightning and Surge Arresters


Surge Arresters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Track Circuit Surge Arresters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Surge Reduction Filter (SRF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Air Gap Arresters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Clear-Comm Lightning Arresters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Heavy Duty Equalisers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

55
56
56
56
56
57

11.3 Resistors
Sealed Resistors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Resistance UnitsAdjustable, Fixed . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

11.4 Tools
Insulated Terminal Wrenches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Relay Tag Crimping Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contact Removal Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Barrier Mechanism Toolkit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Track Circuit Short Finder ...Improved . . . . . . . . . . . . . . . . . . . . . . . .

57
58
58
58
58

13 Services
13.1 Training
Railway Signalling Training . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

13.2 Technical Documentation


Technical Documentation Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

13.3 Refurbishments and Design


Q Relay Refurbishment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Electro-mechanical Refurbishment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Point Layouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60

10

Siemens Rail Automation Pty Ltd 2014. All rights reserved.

SIGNALS

1.1 Colour Light and LED Signals

1. Signals

1.1

Colour Light and LED Signals

1.1.1

Complete Signals
Sigmaguard Style L Signal
Datasheet 1A-12
Mainline LED signal:
one to four aspects
three beam patterns
red, yellow, green, white or blue aspects
110 Vac or 12 Vdc operation
lamp proving option available

Sigmaguard Style LS Searchlight Replacement Signal


Datasheet 1A-16
Multiple aspect LED signal to replace searchlight signals:
two or three aspects
three beam patterns
ac or dc operation
uses existing circuits and wiring

Sigmaguard LED Style U2L Colour Light Signals


Datasheet 1A-19
Underground, yard or subsidiary LED signal:
one to four aspects
red, yellow, green, white or blue
narrow width165 mm
ideal for underground, yard or subsidiary use

Short-Form Catalogue

Issue 26.0

11

1
1.2

SIGNALS
Subsidiary Signals

Sigmaguard LED Style Close-up Signals


Datasheet 1A-20
Used for any short sighting distance applicationco-acting signals,
underground, and other close up uses.
Can be operated in parallel with main signals.

1.1.2

Signal Lamps and LED Retrofit Kits


VELCORP/GEMS Long Life Signal Lamps
Datasheet 1A-18
SL17T

Direct replacement for existing signalling lamps:


available in all standard signalling lamp styles (including SL17 with
pigtail leads)
lifetime in excess of three times standard signalling lamps
precisely-aligned filament for accurate focus
very low rate of light output degradation

Sigmaguard Rear-Access Retrofit Kit for LED Signals


Datasheet 1A-22

Rear-Access
Retrofit Kit

1.2

Maintain 200 mm signals safely:


all future signal module maintenance from rear of signal
suits most 200 mm signals, eg R2, R4 and ML
suits all Invensys Rail RM4 LED signal modules
hoods mount as before
one retrofit kit contains parts for all approved signal types

Subsidiary Signals
Sigmaguard LED Style L Junction Route Indicator
Datasheet 1C-5
LED Style L Junction Route Indicator that mounts to the top of a colour
light signal to indicate when the signal is cleared for a diverging route:
medium range optics
five 127 mm lunar white LED lamp modules
can be inclined 45 to the left or right

12

Siemens Rail Automation Pty Ltd 2014. All rights reserved.

1
1.2

SIGNALS

Subsidiary Signals

Sigmaguard LED Position Light Junction Indicator, PJ2L


Datasheet 1C-14
LED style Position Light Junction Indicator:
can indicate up to six different directions
medium or long range optics
five 127 mm lunar white LED lamp modules for each indicated direction

Sigmaguard LED Style L Position Light Shunt Signal


Datasheet 1C-6
Short range signal:
127 mm LED lamp modules
two or three aspects
red, yellow or white
optional mask
stencil route indicator can be fixed to top of case

Sigmaguard LED Theatre Route Indicator


Sigmaguard LED Dynamic Speed Indicator
Datasheet 1C-10
LED theatre route or dynamic speed indicator:
can display 2 full size or 4 half size characters simultaneously
up to 6 characters in a standard case or up to 10 characters an extended
case
white LEDs for ultra reliability

Sigmaguard LED Banner Repeat Signal


Datasheet 1C-11
An electronic equivalent to a semaphore repeat signal:
signal uses white LEDs on a black bezel
can replace two aspect colour light signals without changing wires or
circuits
110 Vac or 12 Vdc operation
banner display can be discerned at distances greater than 400 metres

Short-Form Catalogue

Issue 26.0

13

1
1.2

SIGNALS
Subsidiary Signals

Sigmaguard LED Guards Indicator and Retrofit Kits


Datasheet 1C-12
210 mm LED guards indicator with same display as existing guards
indicators.

Sigmaguard LED Running Turnout Signal


Complies with Rail Access Corporation Signalling Equipment
Specifications SC 07 10 00 00 SP, version 2.1, April 2000
Indicates left or right turnout

Sigmaguard LED Repeater Signal


Complies with Rail Access Corporation Signalling Equipment
Specifications SC 07 10 00 00 SP, version 2.1, April 2000

LED Turnout Repeat


Complies with Rail Access Corporation Signalling Equipment
Specifications SC 07 10 00 00 SP, version 2.1, April 2000

14

Siemens Rail Automation Pty Ltd 2014. All rights reserved.

1
1.3

SIGNALS

Masts and Hardware

Sigmaguard LED Stencil Route Indicator


Datasheet 1C-15
A short range subsidiary signal:
capable of displaying two characters independently or one symbol
occupying the full width of the display
vertical or horizontal mounting

Sigmaguard LED Marker Light


Datasheet 1C-16
LED Retrofit kits for Victorian Rail Case B116:
hermetically encapsulated LEDs and power supply
multiple LEDs and parallel circuitry
wide voltage range

Sigmaguard Specialist LED Indicators


Datasheet 1C-17
Any symbol, any character and any standard colour.
140, 200 and 300 mm circular modules
single- and multi-aspect cases suit standard mounts
long service life with high reliability LEDs and power supplies
high intensity
wide viewing angle
low power consumption and wide voltage range

1.3

Masts and Hardware


Sigmaguard Easy Access Signal Masts
Datasheet 1E-6
Purpose designed signal mast to place signals where they can be accessed
from the safety of the ground.
Makes maintenance tasks safer and faster.
Lower and raise by one person
Removes EH&S working at heights risks. Never need to climb the mast
Separates maintenance crews from overhead electrical wiring
Eliminates ladders and protective cages
Simplifies installation.

Short-Form Catalogue

Issue 26.0

15

1
1.3

SIGNALS
Masts and Hardware

Sigmaguard Rotatable Top of Post Signal Mount


Datasheet 1E-7
Provides safe access to Easy-Access and standard post mounted signals.
Full front and rear ground access to signals on Easy Access Mast
Front and rear platform access to signals on standard masts
Precision returnlocks to aligned angle after access
Single bolt tilt adjustment up 20, down 10
Secure, high wind proof collar clamp suits 140 mm masts (adaptable to
114 mm masts)
Suits Style L, U2L and other top of post signals
Corrosion resistant

16

Siemens Rail Automation Pty Ltd 2014. All rights reserved.

2
2.1

POINTS

Electric Point Machines

2. Points
2.1

Electric Point Machines

Switchguard One Trough S 700 V Points Operating System


Integrates the proven S 700 V point machine, the locking and the rodding
into a single hollow sleeper.

Removes points operating equipment from between the sleepers.


Improved running dynamics over points
Reduced lifecycle costs
Simple, proven and reliable claw lock rail-head locking or advanced
VAE Spherolock locking system.
Low maintenance intervals with less maintenance and lower lifecycle costs.
Permits automatic tamping throughout the turnout.
Improves track stability.
Suitable for single drive turnouts, multiple drive turnouts and swing
nose crossings

Switchguard M3A Mk II Electric Point Machine


(Emergency Hand Crank)
Datasheet 2A-12
A rugged and dependable point machine for non-trailable applications:
for main line or yard operation of single switch, double slip switches,
catch points and cross-overs
152 mm standard stroke (165 mm extended)
ac or dc operation
hand crank for emergency operation

Switchguard M23A MkII Electric Point Machine (Dual Control)


Datasheet 2A-12
A rugged and dependable dual-control point machine for non-trailable
applications:
for main line or yard operation of single switch, double slip switches,
catch points and cross-overs
152 mm standard stroke
ac or dc operation
hand throw lever

Switchguard Series 84M MkIII Point Machine (Universal)


Datasheet 2A-8
Builds on the features of the 84M universal point machine:
improved end-of-stroke locking
new clutch with improved access, maintenance and reliability
RSA or spring clamp cable termination
detector and throw bars can be grouped for in-bearer applications
upgrade kits converting MkI machines to MkIII are available

Short-Form Catalogue

Issue 26.0

17

2
2.2

POINTS
Pneumatic Point Controllers

Switchguard S 700 K Point Machine

...NEW

Datasheet A19100-V100-B802-V3-7600
For setting points with external locking. Economical and versatile, making
it suitable for use in mass transit and mainline transport with points of all
types and gauges.
Economical operation
High level of availability
Universal application
Robust, compact design
Long service life, long maintenance intervals, short out-of-service
periods

Switchguard SURELOCK

...NEW

Datasheet A19100-V100-B951-X-7600
Point drive system suitable for use in mass transit and mainline
transport.

Mechanically locks the points on completion


Detects Points are closed and locked in correspondence
Tail cables connected using plug-coupler system
Mountable between or beside running rails

Clearguard Circuit Controller Retrofit Kit


Datasheet 2A-5
A switch type circuit controller for rejuvenating older M2, M22, M3A and
M23A point machines.
Directly replaces the old type drum controllers which are difficult to set
and might be near the end of their service life.

2.2

Pneumatic Point Controllers


ES Valve
Datasheet 2C-2
Directly replaces life-expired Style E controllers for pneumatic point
control.
Same fixings, same connections, same operationbut with modern
pneumatic control components.

18

Siemens Rail Automation Pty Ltd 2014. All rights reserved.

POINTS

2.3 Point Locks and Detection

A Valve
Controller for pneumatic points control.

2
2.3

Point Locks and Detection


Switchguard HLM MkII Series Point Locks with Detector
...Improved
Datasheet 2D-6
Combined lock and detector for manually operated points, ground frames
or derails:
0, 1 or 2 detector slides
2-slide models prove normal and reverse positions
optional external hand operated emergency release lever
Upgraded lock detection switch.
Meets AREAM recommendations for a facing point lock.
Lock Bar Retrofit Kit for upgrading older installations but does not meet
AREMA recommendations.

Switchguard HM MkII Series Point Detectors

...Improved

Datasheet 2D-6
Low profile, one to four slide point detectors.
Upgraded point detection switch.

Short-Form Catalogue

Issue 26.0

Series

Feature

HMX
HM

one or two slide point detection in confined spaces.


one to four slide point detection for main or secondary line
points.

19

2
2.4

POINTS
Mechanical Point Equipment

Circuit Controller Style U5A


Datasheet 2D-3
Dual-Switch detector for points, facing point lock and other sliding
equipment:
One or two independent positional detectors
Fine, worm-drive, adjustment
Minimal maintenance (no lubrication)
Large adjustment range
Low profile mounts below structural gauge
Reliable, common style switch

Switchguard ELP 319 End Position Detector

...NEW

Datasheet A19100-V100-B927-V1-7600
Detects the end positions of points (centre lock, high-speed, manually
operated, spring return), mechanical latching devices, movable frogs and
wing rails. Can also be used to detect the locking function, indicate trailing
operations, and detect gauge narrowing.
Slide stroke continuously adjustable from 30 to 190mm.
Fitted without modification to all rail profiles

2.4

Mechanical Point Equipment


Switchguard T21M Point Machine
Datasheet 2H-1
A simple, manually-operated, non-trailable point machine with facing
point lock.
A single hand throw lever operates the lock and throws the points.
Options:
reflective banner to indicate position of points
locking in the reverse position (in addition to the normal position)
electrical detection of point position and locking
electrical release
locking of the hand throw lever with safeworking padlocks, standard
padlocks, or miniature Annett locks

20

Siemens Rail Automation Pty Ltd 2014. All rights reserved.

Switchguard Derail & Crowder

POINTS

2.5

Bearers

...Improved

Datasheet 2H-2
D150 DerailProtects against runaway vehicles entering an operational
line.
C150 CrowderUsed in conjunction with the D150 Derail to prevent rerailing that can occur in some conditions (recommended)
Concrete Bearer Kits everything you need but the thruster, including
derail, crowder, 2 custom concrete bearers, rodding and all fixings to suit
most drives, rail gauges and rail sizes.
MkII Enhancements
more effectively handle vehicles at higher speeds or fitted with bogie
wheels
readily retrofitted to MkI units by replacing single parts in the derail and
crowder

2.5

Bearers
Switchguard In-Bearer Point Drive
Datasheet 2I-1
A comprehensive bearer, point drive and rail head locking solution.
Encases all rodding, detection and point drive within a high strength rolled
steel bearer:
fully machine-tampable
clawlock rail head locking
drive from existing hydraulic, pneumatic or mechanical equipment, or
from 84 Series point machine

Short-Form Catalogue

Issue 26.0

21

2
2.5

22

POINTS
Bearers

Siemens Rail Automation Pty Ltd 2014. All rights reserved.

RELAYS

3.1 Neutral Line Relays, Non-Immune

3. Relays
Relays not listed below are available to special order. Please discuss your requirements
with our sales staff.

Style Q Plug-in Relays Overview


Datasheet 3A

General information.

3.1

Neutral Line Relays, Non-Immune


Relay Style QN1
Datasheet 3B-1
A single-wound dc neutral line relay that complies with BR Specification
930.

Relay Style QNN1


Datasheet 3B-2
A twin single-wound dc neutral twin line relay that complies with BR
Specification 960.

Relay Style QND2


Datasheet 3B-3
A dc neutral line relay that complies with BR Specification 930. It is
identical to the QN1 in all respects except that the coil has two windings,
each of which will operate the relay. The windings can operate
independently, in parallel or be connected in series to provide a higher
resistance at the same voltage.

Relay Style QNND1


Datasheet 3B-4
A twin dc neutral line relay that complies with BR Specification 960. It is
identical to QNN1 in all respects except that each coil has two windings,
either of which will operate the relay. The windings can operate
independently, in parallel or be connected in series to provide a higher
resistance at the same voltage.

Short-Form Catalogue

Issue 26.0

23

3
3.2

RELAYS
Neutral AC-Immune Line Relays

Relay Style QS2


Datasheet 3B-5
A single-wound dc neutral line relay designed to minimise power
consumption. The 24 and 50 volt versions are intended for operation over
very long lines and feature higher normal minimum release to provide
added protection against holding up on stray voltages.

Relay Style QNM1


Datasheet 3B-6
A single-wound dc neutral line relay that complies with BR Specification
930 except for the contacts which are silver cadmium oxide instead of the
standard signalling contacts.

Relay Style QNCD1


Datasheet 3B-7
A dc neutral line contactor relay fitted with two independent windings,
either of which can operate the relay. The windings can operate
independently, in parallel or be connected in series to provide a higher
resistance at the same voltage. Two heavy duty front contacts (complete
with arc quench magnets), rated up to 15 amps at 110 Vdc.

Relay Style QNCM1


Datasheet 3B-8
A dc neutral line contactor relay fitted with two heavy duty front contacts
(complete with arc quench magnets) rated up to 15 amps at 110 Vdc. The
remainder of the contacts are metal to metal (silver cadmium oxide) rated
at 6 amps. These contacts are weld resistant but not non-weldable.

3.2

Neutral AC-Immune Line Relays


Relay Style QNA1
Datasheet 3C-1
A single-wound dc neutral line relay like the QN1 but with additional
immunity to false operation by the application of up to 1000 Vac at 50 Hz.
Complies with BR Specification 931.

Relay Style QNNA1


Datasheet 3C-2
A twin single-wound dc neutral line relay like the QNN1 but with
additional immunity to false operation by the application of up to
1000 Vac at 50 Hz. Complies with BR Specification 966, appendix F6.

24

Siemens Rail Automation Pty Ltd 2014. All rights reserved.

3
3.3

3.3

RELAYS

Neutral Slow Acting, AC-Immune Line Relays

Neutral Slow Acting, AC-Immune Line Relays


Relay Style QSPA1 Slow Operate Track Circuit Relay
Datasheet 3D-1
A single-wound dc neutral slow operate ac-immune relay that complies
with BR Specification 933.

Relay Style QSRA1 Slow Release


Datasheet 3D-2
A single-wound dc neutral slow release ac-immune relay that complies
with BR Specification 934.

Relay Style QSRA4 Slow Release


Datasheet 3D-3
A single-wound dc neutral slow release ac-immune relay that provides a
considerably longer release time than QSRA1. The release time is in excess
of 550 msec when energised at 80% of nominal working voltage.

Relay Style QNNS1 Slow Operate and Release


Datasheet 3D-4
A twin single-wound dc neutral slow operate and release relay that
complies with BR Specification 963.

3.4

Biased AC-Immune Line Relays


Relay Style QBA1
Datasheet 3E-1
A single-wound dc-biased ac-immune relay that complies with BR
Specification 932.

Relay Style QBBA1


Datasheet 3E-2
A twin single-wound dc-biased ac-immune relay that complies with BR
Specification 961.

Relay Style QBCA1


Datasheet 3E-3
A single-wound dc-biased ac-immune contactor that complies with BR
Specifications 943 and 966, Appendix F4 according to contact layout.
Identical to the QBA1 except:
the four standard contacts in the C stack are replaced with two heavy
duty contacts,
the four contacts in the B stack are replaced with magnetic blowouts
for the heavy duty contacts.

Short-Form Catalogue

Issue 26.0

25

3
3.5

RELAYS
Magnetic Latched Line Relays

3.5

Magnetic Latched Line Relays


Relay Style QL1
Datasheet 3F-1
A dc magnetically latched relay that complies with BR Specification 935.

3.6

Track Relays
S

Relay Styles QT1 & QT2


Datasheets 3G-1+2
A dc neutral track relay that complies with BR Specification 938. Also
available with two back contacts which are additional to the specification
requirement for two front contacts only. Several other variants to suit local
requirements are available.

Relay Style QTA2


Datasheet 3G-3
A dc neutral track relay that complies with BR Specification 939 or 966,
Appendix F2. Also available with two back contacts which are additional
to the specification requirement for two front contacts only.

Relay Style QBT1 for Motor Current Proving


Datasheet 3G-4
A dc-biased track relay that complies with all general requirements of BR
Specifications 938 and 932 as far as they are applicable.

Relay Style QTM1


Datasheet 3G-5
A dc neutral track relay similar to QT1 but with metal to metal (silver
cadmium oxide) back contacts. These back contacts (rated at 6 amps) are
weld resistant but not non-weldable.

3.7

Lamp Proving Relays


The QECX20 is specifically designed for LED signals. Other relays were designed for
incandescent signals. Some are usable with LED signals.

Relay Style QECX20 LED Lamp Proving


Datasheet 3H-11
An ac lamp proving relay for LED signals.

26

Siemens Rail Automation Pty Ltd 2014. All rights reserved.

RELAYS

3.7 Lamp Proving Relays

Relay Style QN3 Lamp Proving Multilamp circuits


Datasheet 3H-1
A dc lamp proving relay with no time delay. Typically used where
individual lamp failure detection required in a multilamp circuit.

Relay Style QEC1 Slow Release Lamp Proving 12V lamps


Datasheet 3H-2
A dc slow release lamp proving relay that complies with BR Specification
940. The slow release is adequate to cover the transit time of the signal
control relay.

Relay Style QSR3 Slow Release Lamp Proving


Datasheet 3H-3
A dc lamp proving relay. It can be provided with a full wave rectifier to
facilitate use in AC lamp circuits. The slow release is adequate to cover the
transit time of the signal control relay.

Relay Style QECX5 Slow Release Lamp Proving


110 Vac 18 + 3.5W Twin Filament Lamp
Datasheet 3H-4
An ac lamp proving relay for proving the main filament of a 10 Vac 18 +
3.5 watt twin filament lamp. The slow release is adequate to cover the
transit time of the signal control relay.

Relay Style QECX7 Lamp Proving


10 Vac 18 + 3.5W Twin Filament Lamp
Datasheet 3H-5
An ac lamp proving relay for proving the main filament of a 10 Vac 18 +
3.5 watt twin filament lamp. No time delay results in the voltage drop
being lower than that of the QECX5.

Relay Style QECX8 Lamp Proving 110 Vac 60W Incandescent


Datasheet 3H-6
An ac lamp proving relay for proving a single 110 V 60 Watt lamp.

Relay Style QUCX1 Lamp Proving 110 Vac JRI


Datasheet 3H-7
An ac lamp proving relay that complies with BR Specification 942 to prove
the five lamps of a 110 Vac Junction Route Indicator

Relay Style QNX1 Lamp Proving 35 W Shunt Signal


Datasheet 3H-8
An ac lamp proving relay incorporating an internal rectifier. No time delay
is provided to cover the operating time of other relays.

Relay Style QECX 1,11,15 & 19 Lamp Proving


for SL34 or SL35 110 Vac Lamps
Datasheet 3H-9
An ac slow release lamp (SL34 or SL35) proving relay that complies with
BR Specification 941.

Short-Form Catalogue

Issue 26.0

27

3
3.8

RELAYS
Timers

Relay Style QEECF1 Lamp Proving 12 V Crossing Signals


Datasheet 3H-10
A twin dc operated tractive armature lamp proving relay specifically for
use with road crossing signals. Supersedes relay style QECF1.

3.8

Timers
Timer Style QTD1 Dual Non-Vital
Datasheet 3J-1
A non-fail-safe slow operate electronic unit. Each of the independent
electronic timers can operate several Q style relays in parallel (must have
the same nominal voltage).

Timer Style QTD4 Delay to Drop


Datasheet 3J-2
A safety-critical slow-release electronic unit. Provides a delay between the
opening of a control contact and the subsequent release of a normally
energised slave relay. Any failure will never increase the time by more than
20% of the settings.

Timer Style QTD5 Delay to Pick


Datasheet 3J-3
A safety-critical slow-to-pick electronic timing element and relay all within
a single plug-in Q relay enclosure.

Timer Style QCJ1 Non Vital Point Machine


Datasheet 3J-4
A non-fail-safe slow operate electronic timing relay with fast reset that
meets the requirements of BR 949. Generally used for point machine
protection.

3.9

Transformer-Rectifier Units
Transformer-Rectifier Style QXR1
Datasheet 3K-1
A transformer-rectifier mounted in a Q relay housing designed to operate
a 50 Vdc relay from a 110 Vac 50 Hz line with immunity to false operation
due to dc or line capacitance up to 1 F.

28

Siemens Rail Automation Pty Ltd 2014. All rights reserved.

3
3.10

RELAYS

Special-Purpose Units

3.10 Special-Purpose Units


Style QR Units
Datasheet 3M-1
Various special purpose assemblies of electronic components and small
commercial relays mounted in plug-in Q relay enclosures.

Relay Unit Style QAC1 Battery Charge Fail Detector


Datasheet 3M-2
A battery charge fail detector designed to provide an alarm dependent on
the voltage and current output of a battery charger.
The 12/24 V version monitors chargers with these nominal output
voltages and derives its power from the charger and battery.
The 4 V version derives its power from an external plug pack.

Relay Unit Style QAJTC1


Datasheet 3M-3
Contains an amplifier for the pick-up coil of the intermediate receiver of
the Jointless Track Circuit System FS 2500.

3.11 AC Relays
Relay Style QNHX1 Interface to WESTLOCK and SSI
Datasheet 3N-1
An ac line relay that complies with BR Specification 966, Appendix F7. The
relay is not dc immune.

Relay Style QWCX1for Point Machine Motor Proving


Datasheet 3N-2
A motor current proving relay designed to detect the failure of an ac point
machine motor.

Relay Style QNHCX1 Interface to WESTLOCK and SSI


Datasheet 3N-3
An ac line relay that complies with BR Specification 966, Appendix F7
except for the contacts. The relay is designed to interface with solid-state
interlocking circuitry. It is not dc immune.

Short-Form Catalogue

Issue 26.0

29

RELAYS

3.12

Relay Plug Board

3.12 Relay Plug Board


Relay Plug Board
Datasheet 3A
For permanent mounting in relay cabinets:
insertable wiring connectors
keyed holes engage pins on relay base to ensure incorrect relay cannot
be mounted.

30

SECTION 4 IS NOT IN USE.

Siemens Rail Automation Pty Ltd 2014. All rights reserved.

TRAIN DETECTION

5.1 Audio Frequency Overlay Track Circuits

5. Train Detection
5.1

Audio Frequency Overlay Track Circuits


Clearguard Intelligent Processor Island Track Circuit (IPITC)
Datasheet Sb-06
A modulated audio frequency track circuit that can be overlaid on other ac
or dc track circuits. Any of 12 frequencies can be selected. All in a single
housing. Used for level crossing islands and other short track circuits.

Clearguard Phase Shift Overlay 4000 (PSO 4000)


Datasheet 5A-4
An updated overlay track circuit directly compatible with PSO II and PSO III
track circuits with new features:
minimised spares holding because each unit is frequency-configurable
separate transmitter, receiver, transceiver and crossing modules
greater flexibility with new frequencies and new codes
internal data log
internal stick logic in crossing module
improved safety with greater immunity for spurious frequency and
modulation

Wayguard PSO GCP 4000


Datasheet 9G-8
A complete PSO Crossing Systemsee section 9.5, page 42.

Clearguard Series Overlay Circuit Track Circuit (SOTC)


Datasheet Sd-5
An adjustable length audio frequency rail circuit intended primarily for
obtaining release of electrically locked points
The SOTC contains both transmitter and receiver and three frequencies are
available: 5900 Hz, 10.0 Hz and 26.0 Hz.

Short-Form Catalogue

Issue 26.0

31

5
5.2

TRAIN DETECTION
Track Feed Sets

5.2

Track Feed Sets


Style WA15Q Track Feed Set
Datasheet 5B-1
DC Track Feed set powered from 110 Vac 50 Hz supply.

Style R5-9 AC-Immune Track Feed Set


Datasheet 5B-2
Complies with BR Specification 867 suitable for dc track circuits operated
by 25 kV 50 Hz overhead traction. When used with a 9 ohm ac-immune
track relay to BR 966, Appendix F2, the track circuit will have immunity to
traction interference up to 100 V 50 Hz and the feed set will withstand
430 V 50 Hz without damage.

WESTRAK Track Feed Set


Datasheet 5B-4
Occupies the space of two Q relays.

WESTRAK Diode Unit

5.3

Impedance Bonds
High Current Impedance Bonds
Datasheet 5C-5
Designed to carry very high track currentsup to 4000 amps per rail for
short duration. Models suit 50 Hz, jointless (1700 - 2600 Hz) and high
voltage impulse tracks

32

Siemens Rail Automation Pty Ltd 2014. All rights reserved.

TRAIN DETECTION
5.4 Accessories

5.4

Accessories
Style TD4 Track Disconnection Box
Datasheet 5D-1
A robust aluminium alloy die-cast box and cover to accommodate the
transition and termination of track cables.
Cable entry through hollow mast or through glands fitted in the base of
the box.

5.5

Jointless Track Circuit Equipment

Clearguard TCM 100 Track Vacancy Detection


System ...NEW
Datasheet A19100-V100-B935-V1-7600
Maximum safety with fail-safe clear or occupied indication. High
flexibility from modular architecture, connectivity to any type of
interlocking or subsystem, & support for standard, centre-fed, or point
track circuit. Reduced maintenance from maintenance-free modules &
use of a single module type.

Clearguard FS2550 Jointless Track Circuit


Datasheet 5E-6
A family of Jointless Track circuit, transmitters, receivers, tuning units and
intermediate receivers, compatible with FS2500, UM71 and TI21. Upgrade
from FS2500 with enhanced reliability and performance. 1700, 2000,
2300 and 2600 Hz operating frequencies.

5.6

Relay Track Circuit


VT1 ac Track Circuit
Datasheet 5H-1
For dc traction areas where only one rail need be used for traction current
return.
Variant also available for double rail applications.

Short-Form Catalogue

Issue 26.0

33

5
5.7

TRAIN DETECTION
Axle Counters

5.7

Axle Counters
Clearguard ACM200 Axle Counting System
Datasheet A19100-V100-B927-V1-7600
Smart track vacancy detection for cost-effective operations. Comprising
maintenance-free modules, programmed via an ID plug and combined
with an Ethernet bus and Clearguard ZP 43 E/V and ZP D 43 counting
heads into a fail-safe axle counting system.

Connection to electronic and relay interlockings


HTML communication for attribute configuration, logging and
diagnostics
Modular, compact hardware
Innovative diagnostic concept
Deployment of Clearguard ZP 43 E/V and ZP D 43 counting heads

Clearguard ACM100 Axle Counting System


Datasheet A19100-V100-B927-X-7600
Smart track vacancy detection for cost-effective operations. Comprising
maintenance-free Clearguard ACM 100 modules, programmed via an ID
plug and combined with an Ethernet bus and Clearguard WSD wheel
detectors into a fail-safe axle counting system.

34

Connection to electronic and relay interlockings


HTML communication for attribute configuration, logging and
diagnostics
Modular, compact hardware
Innovative diagnostic concept
Low-cost Clearguard WSD wheel detector

Siemens Rail Automation Pty Ltd 2014. All rights reserved.

TRAINSTOPS

6.1 Trainstops (Trip Type)

6. Trainstops
6.1

Trainstops (Trip Type)


Trainguard Trainstop, Style JA
Datasheet 6A-1
An electrically-controlled, pneumatically-operated trip arm trainstop that
provides reliable protection against brake trip cock equipped trains
moving beyond their authorised space.

Trainguard Trainstop, Style JAH


Datasheet 6A-2
An electrically-controlled, hydraulically-operated trip arm trainstop that
provides reliable protection against brake trip cock equipped trains
moving beyond their authorised space.
Can also be remotely powered by an E1 Style Trainstop Power Unit.

Trainguard Trainstop Power Unit, Style EH1


Datasheet 6A-4
An alternative power source for the JAH Style Trainstop.
Moves the power supply away from the trainstop for the following
benefits:
easier, safer and more cost-effective servicing
reliable trainstop operation in flood prone areas when the power unit is
kept above the flood level

Clearguard Circuit Controller Retrofit Kit


Datasheet 6A-5
A replacement for drum-type circuit controllers with exposed contacts in
older J-series trainstops.

SECTION 7 IS NOT IN USE.

SECTION 8 IS NOT IN USE.

Short-Form Catalogue

Issue 26.0

35

6
6.1

36

TRAINSTOPS
Trainstops (Trip Type)

Siemens Rail Automation Pty Ltd 2014. All rights reserved.

LEVEL CROSSING PROTECTION

9.1 Flashing Lights & Accessories

9. Level Crossing Protection


9.1

Flashing Lights & Accessories


Wayguard Level Crossing Light Crossarms
Datasheet 9A-2

Proven functional and flexible design


Minimised stock - just 4 kits cover every application
Full adjustment for aiming lights
All componenets powder coated black as standard
Terminal box with 6 pairs M6 Studs as standard
Supplied in easily manageable, un-assembled packs
Suits 2 or 4 HC101L (210 mm) or HC300L (300 mm) crossing signals

Sigmaguard LED Crossing Signals & Retrofit Kits


Datasheet 9A-3
Complete signals and retrofit kits using LED technology:
complete signalsHC101L (210 mm) & HC300L (300 mm)
retrofit kitsavailable for most existing signals
LEDs are high-safety, low-maintenance replacements for incandescent
signals and lamps. They provide constant brightness over a wide voltage
range and use about half the power of incandescent signals.

9
Sigmaguard LED Barrier Arm Lights
Datasheet 9A-4
A fully-sealed light for installation on level crossing barrier arm.
Each unit is supplied with a cable that connects to the barrier-mounted
junction box, or as a combined double-sided light and junction box.
The lights do not require voltage-setting resistors but will work with them
in retrofit applications.

Wayguard SAFEFLASHLevel Crossing Flasher


Datasheet 9A-5
A safety-critical level crossing flasher meeting modern standards of safety,
quality and reliability.
Only one SAFEFLASH unit is typically needed to control the flashing lights
of an entire crossing installation.
The unit is self-contained and is designed to mount on Q relay style rails,
a backboard or similar. It makes the replacement of existing flasher units
as simple as possible.

Short-Form Catalogue

Issue 26.0

37

9
9.2

LEVEL CROSSING PROTECTION


Barrier Mechanisms

Wayguard SSCC III PlusSolid-State Crossing Controller


Datasheet 9A-6
A solid-state crossing controller that incorporates everything, other than
train detection, that you need for a crossing control, in a single box.
The SSCC III Plus directly interfaces with flashing lights, barriers, bells and
track circuitsand you retain control over all settings.

9.2

Barrier Mechanisms
Wayguard Circuit Controller and Motor Retrofit Kits
Datasheet 9B-5
These retrofit kits are based on parts from the Style EB barrier mechanism.
They contain modern circuit controllers and motor to extend the life of
older style WRRS barrier mechanisms.

Wayguard S-60 Level Crossing Barrier Mechanism


Datasheet 9B-9
Ideal for operating crossing entrance and exit barriers for level crossing
protection. Wide range of variantsincluding 12 and 24 Vdc input,
entrance and exit gatesto cover all applications.
The S-60 operates barrier arms up to 12 metres in length.
Robust barrier arm mechanism
Proven reliabilitybased on S-20 and S-40 predecessors
Power up, power down to 70 then gravity descent in a controlled
manner
Maintenance switch to drive mechanism down when arm is knocked off
Suits aluminium, aluminium-fibreglass, and timber barrier arms
LED diagnostics and overspeed protection to prevent damage after arm
broken
Advanced gearmotor and electric brake combination
Intelligent auto-reset overload circuit protects motor and circuit board
if obstruction stalls mechanism
Horizontal and vertical buffers adjusted externally
AREMA-compliant

Wayguard S-20/S-40 to S-60 Retrofit Kit

...NEW

Datasheet 9B-9
Cost competitive upgrade of an S-20 or S-40 barrier mechanism to S-60
functionality and features (see above).

38

Siemens Rail Automation Pty Ltd 2014. All rights reserved.

LEVEL CROSSING PROTECTION


9.3

9.3

Barrier

Barrier
Wayguard Level Crossing Barrier Arms
Datasheet 9C-2
Barrier arms for any situation:
all-aluminium, aluminium-fibreglass or all-fibreglass
lengths up to 12 metres (40 feet), longer by special design
telescoping design for maximum strength and minimum wind
resistance
modular construction for easy assembly and replacement
red and white reflective finish on both sides
LED or incandescent arm lamps easily fitted, or arms supplied with
lamps fitted
high-wind (eg 150 kmh) arms, masts, supports and fittings available
optional insulated tips
AREMA-compliant

Wayguard Pre-Dressed Level Crossing Barrier Arms

...NEW

Datasheet 9C-4
Barrier arms:
ready to install at the required length
pre-fitted with low maintenance LED lights (to AS1742.7 or as required)
and markings
wiring with plug-in design
all-aluminium, aluminium-fibreglass, or all-fibreglass; includes highwind resistant variants
lengths up to 12.7 m

9.4

Warning Bells
Wayguard Level Crossing BellSolid State
Datasheet 9D-4
This solid-state bell sounds exactly like a real bell, yet has no mechanical
parts to break or wear out. It cannot be affected by dirt, water or wear, and
never requires adjustment.
The bell fully integrates with SEAR II crossing monitors for direct reporting
of bell energisation and sound level (using an inbuilt microphone) over
the bell control wires.

Short-Form Catalogue

Issue 26.0

39

9
9.5

LEVEL CROSSING PROTECTION


Grade Crossing Predictors

9.5

Grade Crossing Predictors


Wayguard Grade Crossing Predictors4000 Series (GCP 4000)
Datasheet 9G-3
Complete crossing control solution in one boxjust add power.
slash design, installation and commissioning costs
control complex, multiple (15) independent crossings from one unit
simple configuration using pre-defined templates
integrated flasher, bell and barrier control optional SEAR IIi event
recorder
three models: Basic GCP (single track), Basic Crossing (single track,
controller and user interface), Multiple-Track Crossing (15 independent
tracks, controller, user interface and SEAR IIi)
See also Wayguard AccessoriesGrade Crossing Predictors on page 41.
Replaces 3000 Series GCPs.

Wayguard Motion Sensor 4000 (MS 4000)

...NEW

Reliably detect the motion of an approaching train and start the crossing
warning system.
Configurable as a basic motion sensor type or grade crossing predictor
type controller
Available as a redundant or non-redundant, single track controller.
Uses proven GCP 4000 modules
Simple user interface to easily program and set up the unit
Provides diagnostic history & train move history logs; can interface to a
SEAR II Recorder/Analyzer for additional recording capability.

40

Siemens Rail Automation Pty Ltd 2014. All rights reserved.

LEVEL CROSSING PROTECTION


9.5

Grade Crossing Predictors

Wayguard AccessoriesGrade Crossing Predictors


Datasheet 9G-4
Accessories and replacement parts for the 3000 and 4000 Series GCPs:
narrowband shuntssingle-frequency, multi-frequency and lowloading)
wideband shunt
bidirectional simulation couplers
simulated track inductorsfixed and adjustable
battery chokes (blocking reactors)
tunable IRJ bypass couplers
surge panels

Wayguard DC Shunting Enhancer Panel


Datasheet 9G-7
A very cost-effective solution for improving shunting in areas where
marginal shunting is a problem. The unit applies a nominal 6 Vdc to the
track at the crossing to break down the oxide film on the rails.
Suits 3000 and 4000 Series GCPs.

Short-Form Catalogue

Issue 26.0

41

9
9.6

LEVEL CROSSING PROTECTION


Installations

Wayguard PSO GCP 4000


Datasheet 9G-8
A complete level crossing solution in one box for use where GCPs are not
appropriate. Adds PSO 4000 track circuits to the proven crossing control
of GCP4000.
slashes design, installation and commissioning costs
integrates multiple PSO tracks and island tracks with crossing control
and diagnostics
integrated flasher, bell and barrier control plus optional SEAR IIi event
analyser
powerful logic to interface with signalling system
suits electrified and non electrified railways
integrated stick logic and release timers

9.6

Installations
Crossing in a Box
Datasheet 9H-1
Pre-wired, pre-tested, comprehensive kit of parts and installation
locations, standardised to local Rail requirements. Packed into lockable
container so they can be removed in order of installation. Radically cuts
time on site to install and test crossing and delivers lower total installed
costs.

42

Siemens Rail Automation Pty Ltd 2014. All rights reserved.

10

CONTROL AND SIGNALLING SYSTEMS


10.1

Computer-Based Interlockings

10. Control and Signalling Systems


10.1 Computer-Based Interlockings

Interlocking Systems
Datasheet 10A-33
Design optimum interlocking system from inter-operational WESTLOCK
and WESTRACE Components. Use WESTLOCK with SSI style data and
WESTRACE with ladder logic data or combine the two.
Integrated family of interlockings
Very high data capacity eliminates cross boundary data
Fast response times
Suits both distributed and centralised architectures
High availability just where you need it
ERTMS & ETCS compatible
Industry-standard communication
Design and service tools slash costs
Hot-swap maintanable
No fleeting outputs
SSI or ladder logic
Re-use current interlocking data
WESTRACE
interlockings

Trackguard WESTRACE MkII Interlockings


Datasheet 10A-38
WESTRACE MkII Interlockings cut your whole of life interlocking cost.
Utilising the logic and safety proven in earlier WESTRACE interlockings and
adds
Very high data capacity (all vital and non vital data processed together,
vitally in one cycle)
Response times as fast as relay interlockings
Flexible architecturedistributed, centralised or combined
High availability where required
Hot swap any module without configuration
No fleeting outputs
Re-use interlocking data
Industry standard communications

WESTRACE
object controllers

Trackguard WESTRACE Object Controllers


Datasheet 10A-32
Use WESTRACEs new modular Object Controllers to distribute input and
output control to minimise signalling wiring:
works with both WESTRACE and WESTLOCK interlockings
Maintainer-resistant enclosed modules
hot-swap modules don't need configuring for replacement
connected via Ethernet or direct optical fibre

Short-Form Catalogue

Issue 26.0

43

10

10
10.1

CONTROL AND SIGNALLING SYSTEMS


Computer-Based Interlockings

Trackguard WESTRACE GCSS


Datasheet 10A-3
A PC-based tool with an easy-to-use graphical interface that makes
designing and configuring WESTRACE and iViu interlockings a simple and
efficient task.

Trackguard WESTRACE GSIM


Datasheet 10A-4
A PC-based simulator for WESTRACE Interlockings. Simulate multiple
WESTRACEs simultaneously, as well as interface to MoviolaW and
WESTCAD.

Controlguide MoviolaW
Datasheet 10A-31
A PC-based graphic display and recording, logging and replay tool that
supports WESTRACE, SSI and relay interlockings (via WESTRONIC S2).
Users can see, in real time, the state of one or more interlockings and
object controllers on a familiar mimic panel screen. MoviolaW displays
track circuits, points, signals and other equipment for easy understanding
of the their status.
Easy-to-read system fault messages
High capacity logging of all system events
Graphical replay of logged data
Remote access via modem or WAN
User-configurable event counting and reporting
Capable of displaying multiple interlockings on a single interface
User-configurable track layouts with the optional PC Graphics Editor
(PCGE)

Trackguard WESTLOCK
Datasheet 10A-9
A 4th generation computer-based interlocking that is the natural successor
to SSI that does not expose rail infra-structure owners to unnecessary
write-offs with existing SSI assets.
WESTLOCK features:
central interlocking processorsexecute dual diverse logic using triple
modular redundant hardware architecture and dual diverse software
trackside modulesprovide the interface between the Central
Interlocking Processors and the trackside equipment
configuration toolsbased on NT, these tools configure WESTLOCK
installations and enable operation simulations
diagnostic toolsincluding technicians workstation, remote
diagnostics, event recording and playback

44

Siemens Rail Automation Pty Ltd 2014. All rights reserved.

10

CONTROL AND SIGNALLING SYSTEMS


10.2

Telemetry Systems

Trackguard Solid-State Interlocking (SSI)


Datasheets 10A-11 to 10A-28
A complete range of components for the British Solid-State Interlocking.

Use WESTLOCK or WESTRACE for


all new installations

Vital Signal Logic Simulator (VSLS)


Datasheet 10A-34
A powerful and efficient tool for checking interlocking logic designs. A click
of the mouse toggles the state of any input, and the resulting changes in
signal aspects and other outputs are easily observed.
Office-test complete interlocking systems
Test systems of multiple connected interlockings and communications
Simultaneously test vital and non-vital logic
Supports most interlocking systems, eg MicroLok, Microtrax, VHLC, VPI,
Relay
Automate repetitive testing with easily-recordable scripts
Prepare field test lists
Useful training tool
Runs on Windows XP with multiple monitors

10.2 Telemetry Systems


Controlguide WESTRONIC S2 (System Two)
Datasheet 10B-3
Powerful SCADA applications with the additional benefits of localised and
distributed processor capabilities.
A range of specialised I/O modules provide an interface to the target
application while a similar range of bearer interface modules
communication with the transmission medium.

Controlguide WESTRONIC S2 Telemetry Scanner Modules

S2/SCN41
Enhanced
scanner
module

Datasheet 10B-4
S2/SCN42
Standard
scanner
module

Short-Form Catalogue

Issue 26.0

The S2 Scanner Module forms the controlling element of the WESTRONIC


S2 subsystem by controlling all of the input and output modules.
Two models: S2/SCN41 (enhanced), S2/SCN42 (standard)

45

10

10
10.2

CONTROL AND SIGNALLING SYSTEMS


Telemetry Systems

Controlguide S2/DIP42 Digital Input Module


Datasheet 10B-5
This module interfaces with the S2 Telemetry Scanner Modules to provide
32 digital inputs to the WESTRONIC S2. Inputs are filtered and buffered by
logic gates to prevent corruption by electrical noise.
Input is active low.

Controlguide S2/DIP43 Digital Input Module


Datasheet 10B-6
This module interfaces with the S2 Telemetry Scanner Modules to provide
32 digital inputs to the WESTRONIC S2. Inputs are filtered and buffered by
logic gates to prevent corruption by electrical noise.
Input is active high.

Controlguide S2/DOP42 Digital Output Module


Datasheet 10B-7
This module interfaces with the S2 Telemetry Scanner Modules to provide
32 digital outputs from the WESTRONIC S2 capable of driving external
relays referenced to supply.

Controlguide S2/DOP43 Digital Output Module


Datasheet 10B-8
This module interfaces with the S2 Telemetry Scanner Modules to provide
32 digital outputs from the WESTRONIC S2 capable of driving external
relays referenced to ground.

Controlguide S2/ALC Alarm & Line Changeover


Datasheet 10B-9
Provides ancillary functions to the WESTRONIC S2 telemetry system
including power failure, bearer failure or user defined alarm functions. It
can also provide attenuator switching, telemetry force off, and a selection
of manual or automatic line/bearer changeover/hunting functions.

Controlguide WESTRONIC S2/PSU Power Supply Module


Datasheet 10B-10
These modules provide simple plug-in performance for most of the most
of the standard supply voltages used throughout the railway industry.

Controlguide S2/SLC Serial Line Converter (RS232-RS422)


Datasheet 10B-14
Provides level conversion between RS232 and RS422 interface standards,
8 channels in each direction with an option of 16 channels.

46

Siemens Rail Automation Pty Ltd 2014. All rights reserved.

10

CONTROL AND SIGNALLING SYSTEMS


10.2

Telemetry Systems

Controlguide S2/VFC45 Voice Frequency Modem CCITT V.23


FSK
Datasheet 10B-21
Operates over a voice frequency channel (3003400 Hz) at 1200 bps full
duplex on 4 wire operation. Can be used in point-to-point or multi-drop
configurations. A front mounted serial (RS232c) port is available for
external user requirements.

Vital and Non-Vital Communication Systems


Datasheet 10B-27
Wayside communication without cable costs is explained in this datasheet.
It shows how Echelon, Ethernet and serial networks can be integrated
along a railway using LIPD class licence spread-spectrum radio, media
bridging and intelligent routing.
See also:
Datasheet 10B-15HD/Link
Datasheet 10B-24Ethernet Spread-Spectrum Radio
Datasheet 10B-26Wayside Access Gateway (WAG)

HD/Link System
Datasheets 10B-15 and 10B-27
A vital telemetry system that can operate over a local network, use spread
spectrum radio or other bearers. Ideal for pole line replacement, cable
elimination, or vital timer applications.

Ethernet Spread-Spectrum Radio (ESSR)


Datasheets 10B-24 and 10B-27
An Ethernet-enabled spread-spectrum radio with versions for operating
under a no-fee class licence in the 900 MHz and 2.4 GHz ISM (industrial,
scientific and medical) bands. Establish point-to-point, point-to-multipoint
and linear networks without the expense and time of installing cable.
Use with HD/Link, or as part of vital and non-vital telemetry.

Wayside Access Gateway (WAG)


Datasheets 10B-26 and 10B-27
The WAG is an intelligent media converter that bridges communication
between Echelon, Ethernet and serial network technologies.
It connects directly to the Ethernet Spread-Spectrum Radio (datasheet
10B-24) to link where no other communication exists.

Short-Form Catalogue

Issue 26.0

47

10

10
10.3

CONTROL AND SIGNALLING SYSTEMS


Train Control Equipment

CNA2000 Network Adapter


Datasheet 10B-30

Interfaces Siemens and third-party signalling and control systems


Interfaces serial and packet-switched communications
Provides IP access to remote field equipment
Communicates over public and private networks
Supports ATCS addressing
Other custom protocols can be supported

10.3 Train Control Equipment

Train
Graph

Controlguide Rail 9000

Main Rail 9000 Signallers GUI

ARS Operators
Interface (AOI)

Datasheet 10C-7
Rail 9000 is a single Control Centre that consists of a set of central servers
and multiple Signaller workstations (clients). Each Signaller:
can always see all of the railway;
can control any number of zones within the railway
can assign, remove or query zones
Signallers use Rail 9000s mouse or keyboard to create and send commands
to interlockings, and receive feedback from the interlocking on their multimonitor display.

Controlguide WESTCAD
Datasheet 10C-2
A PC-based control and display system that provides a flexible, costeffective alternative to hard-wired panels.
Supports multiple monitors and can control most local and remote
interlockings.

10.4 Automatic Train Control and Protection


Trainguard WESTECT II ATP (Automatic Train Protection)
...Improved
Datasheet 10F-2
A continuous radio-based ATP system that ensures trains:
cannot move without the interlockings authority
cannot exceed speed limits
cannot pass signals at stop
cannot roll away accidentally
Shunting trains are limited to safe speeds and distances.
Speed and performance are not sacrificed to achieve these benefits.

48

Siemens Rail Automation Pty Ltd 2014. All rights reserved.

10
10.4

Trainguard ETCS

CONTROL AND SIGNALLING SYSTEMS

Automatic Train Control and Protection

...NEW

Datasheet A19100-V100-B875-V3-7600
ETCS is the basis for interoperability between on-board and trackside
equipment from any supplier. Provides signal aspect and line profile,
including line speed & speed restrictions, to the driver; on-board system
applies brakes, if necessary.
Siemens provides a complete, integrated portfolio of products conforming
to ETCS specifications, including:
ETCS Level 1
Trainguard 100 on-board equipment for ETCS Level 1
Trainguard Eurobalise S21 and S22 for track to train communications
Trainguard Lineside Electronics Unit (LEU)S2 to link signals with
Euroblaises and Euroloop
Trainguard Euroloop S21 F to complement Eurobalises for shorter
headways
Trainguard Basic Indusi for migrating Indusi/PZB 90 into ETCS
ETCS Level 2
Trainguard 200 on-board equipment for ETCS Level 2
Trainguard Radio Block Centre

Control Centre

iVIU trackside
Vital Interface Unit

Trackguard Train Sentinel


Datasheet 10A-36

iVIU
Universal Track
Module

Train Sentinel
onboard display
and control

Move beyond paper-based train order and track warrant systems with Train
Sentinel delivering non-conflicting electronic train orders with protection
against exceeding these authorities.
Faster, more efficient and safer than manual systems
Mimic and train graph based authority generation
Points controlled, locked and detected via data circuits
Authority exchange via data radio (with optional voice confirmation)
Driver has written and graphical authority
Prevents exceeding movement and speed authority
Automated authority rollup after train
Easy and small to retrofit
Retrofit to dark and CTC territory

10

End of Train Devices


Datasheet 10F-6
The Siemens series of End-of-Train (EOT) devices includes a standard EOT
and a mobile modem equipped EOT for remote tracking. Both styles share
the following features:
High strength, polymer enclosure
Enclosed antennas & AEI tag
Positive, horizontal 4 hole mounting mechanism
Battery charging air generator
External battery charging port
Internal event recorder
High visibility marker
GPS receiver
8 character display

Short-Form Catalogue

Issue 26.0

49

10
10.5

CONTROL AND SIGNALLING SYSTEMS


Automatic Equipment Identification (AEI) Systems

Head of Train Devices


Datasheet 10F-7
Train complete detection cab equipment for use with Siemens and
Industry standard End of Train Device. Communicates with End of Train to
determine:
Train complete
Motion Detector
Brake pip pressure
Battery status
Optionally, apply emergency brake

10.5 Automatic Equipment Identification (AEI) Systems


Transcore Automatic Equipment Identification
Datasheet 10G-1
A fast, accurate and reliable means of identifying containers or rolling
stock whether stationary or moving at speeds up to 300 km/h.

Trackguard WESTECT Portable Transponder Reader Module


(PTRM)
Datasheet 10G-26

Lightweight ergonomic design for easy, comfortable tag reading


Use in harsh operating environments
Displays tag data on sunlight readable screen
Logs WESTECT reads for later download via USB or ethernet
Versions for standard transportation and WESTECT tags

Transcore AI1200 Reader


Datasheet 10G-4
Provides an operational link between tagged objects and the host
information management systems.

Transcore AR2200 RF Module


Datasheet 10G-5
This is a dual output radio transmitter-receiver controlled by a Transcore
reader (eg AI1200). Upon command from the reader, the module
generates and broadcasts an RF signal from one or two antennas. It then
receives, demodulates, amplifies and conditions the signal reflected from
a tag and delivers it to the reader.

50

Siemens Rail Automation Pty Ltd 2014. All rights reserved.

10
10.5

CONTROL AND SIGNALLING SYSTEMS

Automatic Equipment Identification (AEI) Systems

Transcore Encompass 4 RFID Tag Reader


Datasheet 10G-6
This is an antenna, radio frequency module, tag decoder, and power
supply in one integrated package. New low power model does not require
a separate ACMA licence.

Transcore AA3233-004 Heavy Rail Antenna


Datasheet 10G-22
A rugged 915 MHz antenna specifically designed for mounting between
track rails:
constructed for high shock and vibration environments
rugged weatherproof enclosure that provides protection from harsh
environmental conditions encountered on railroad tracks
dimensions compatible with mounting under the locomotive

Transcore AA3234 Light Rail Antenna


Datasheet 10G-21
Designed specifically for light rail applications requiring a low profile, such
as the undercarriage of commuter trains and people mover systems:
constructed for high shock and vibration environments
rugged weatherproof enclosure
dimensions compatible with mounting underneath trains

Transcore AA3110 Parapanel Antenna


Datasheet 10G-7a
Used to broadcast and receive radio frequency signals in the 902 to
928 MHz RF band.

10

Short-Form Catalogue

Issue 26.0

51

10
10.5

CONTROL AND SIGNALLING SYSTEMS


Automatic Equipment Identification (AEI) Systems

Transcore AT5118 Rail Harsh Environment Rail Tag


Datasheet 10G-25
Beam-powered general use Rail Tag, ideal for mounting on railcars, vehicle
chassis or inter-modal containers.
harsh-environment durability
factory-sealed case
factory-programmed or field-programmable
1088-bit data storage
data encryption and authentication
fully compliant with Association of American Railroads (AAR), American
Trucking Association (ATA) and TransCore Super eGo(SeGo) protocols

Transcore AT5413 Hardened Rail Tag


Datasheet 10G-28
Beam-powered hardened Rail Tag ideal for mounting on sleepers. Use for
WESTECT ATP.
harsh-environment durability
factory-sealed case
factory-programmed or field-programmable
1088-bit data storage
data encryption and authentication
fully compliant with Association of American Railroads (AAR), American
Trucking Association (ATA) and TransCore Super eGo(SeGo) protocols

Transcore PT5780 Permissions Tag


Datasheet 10G-24
Used to configure the AP4118 Rail Tag Programmer.
secure tag data can be used by AP4118 Rail Tag Programmer only
can be used once or multiple times where scheduled reconfigurations
are required
factory programmed to specific customer requirements
uses Super eGo (SeGo) operation mode
factory-sealed case

Transcore AT5720 Check Tag


Datasheet 10G-10
Provides a means for performing end-to-end status checks of Transcore
systems.

52

Siemens Rail Automation Pty Ltd 2014. All rights reserved.

10

CONTROL AND SIGNALLING SYSTEMS

10.6

Fault Monitoring and Data Logging

Transcore AP4118 Rail Tag Programmer


Datasheet 10G-23
Used to program AT5118 Rail Tags, which use Super eGo protocol.
Programming occurs via a radio frequency (RF) signal.
Tag programmer functions include programming permissible tag data
pages and interrogating permissible data pages.
Tag data pages can be easily programmed.

10.6 Fault Monitoring and Data Logging


Wayguard SEAR II Event Analyser and Recorder
Datasheet 10H-3
The second generation Safetran Event Analyser and Recorder.
SEAR II is a non-vital stand-alone system designed to provide continuous
real-time general purpose status monitoring and event recording for a
wide range of functions associated with a crossing, interlocking, or similar
installation.

Wayguard SEAR II Accessories


Datasheet 10H-4
These accessories extend SEAR II crossing monitoring for comprehensive
detection of flashing light, bell or barrier arm failures.

Axle Counter SEAR Island Interface (ACSI)


Datasheet 10H-7

10

Pseudo Island for connecting Frauscher Axle Counters to SEAR


Allows SEAR to monitor crossing warning time
Simple island simulator
Plug connection to axle counter
No axle counter modification required
Uses standard SEAR application

Wayguard Argus Event Recorder


Datasheet 10H-5
A compact, inexpensive, non-vital stand-alone unit for conventional level
crossings.
Argus monitors and logs railway events, generates alarms based on sitespecific criteria, and produces reports.
USB port for transfer of software, logs and reports via memory stick
Ethernet port for logging and Telnet

Short-Form Catalogue

Issue 26.0

53

10

CONTROL AND SIGNALLING SYSTEMS

10.7

Integrated Communication and Control Systems (ICSS)

Condition Monitoring
Datasheet 10H-6
Struktons POSS condition monitoring system widely used throughout
Europe is now available from and supported by Siemens

Monitors points, tracks, axle counters and crossings


Reduce train delays due to points failure by 25% to 50%
Immediate advice of failures
Identify degradation before it leads to failures
Identify most likely problem before attending site
Improve maintenance planning with operational statistics
Improve training based on degradation and failure statistics
24 * 7 monitoring and access from anywhere via web browser

10.7 Integrated Communication and Control Systems


(ICSS)
Controlguide SystematICS
Integrated Railway Management Solutions
Datasheet 10I-1
...

Train Describer

Voice

FIRE Control

TRACTION

ELECTRICAL

MECHANICAL

SECURITY

RailSCADA

SystematICS Platform

Improve efficiency, reduce costs and enhance operational capability.


SystematICS is a high-performance, scalable, open control systems product
that provides the core platform for a wide range of applications for the rail
control environment.
Also see Controlguide SystematICS RailSCADA.

Controlguide SystematICS RailSCADA


Intelligent Rail Management Applications
Datasheet 10I-2
Use SCADA telemetry and data processing for:
complete station management (including security and fire
management)
electrical and mechanical plant management
traction power management
environmental management

54

Siemens Rail Automation Pty Ltd 2014. All rights reserved.

11
11.1

ACCESSORIES
Terminal Blocks

11. Accessories
11.1 Terminal Blocks
RSA Double-Row Terminal Blocks
Datasheet 11A-1
A range of M5 and M6 terminal blocks (complete with nuts and washers),
shorting links and insulating links.
Available from 1 to 6 way (2 to 12 studs).

11.2 Lightning and Surge Arresters

Surge Arresters
Datasheet 11D-1
Every WESTRACE input and output connected external to the SER or
location case should be protected from the impact of transient voltages.
These WESTRACE specific surge arresters protect against common or
differential mode transients.
Fulfils WESTRACE Safety Requirements
50 Vdc and 110 Vac inputs
Repeatable protection up to 10 kA
Complies with relevant functional and safety standards
Visual indication of input or output state via LED
Visual indication of unit health via LED when ON
Separate base and surge protection module; colour coded base to
prevent incorrect module insertion
Available for 35 mm T or 32 mm G DIN rail
Earth connection via rail or separate terminals
Isolates WESTRACE on excessive fault current

Short-Form Catalogue

Issue 26.0

55

11

11
11.2

ACCESSORIES
Lightning and Surge Arresters

Track Circuit Surge Arresters


Datasheet 11D-2
Minimise damage to track circuits with this robust surge protection device
that protects equipment from high voltage, high energy transients.
One compact unit with:
Line Line (differential modeequaliser)
Line Earth (common modearrester)
Benefits:
Use in electrified or non-electrified territory
Suit dc, ac, jointless, overlay, predictor tracks and most other units
Automatic reset once disturbance past
Minimise costly down time

Surge Reduction Filter (SRF)


Datasheet 11D-3
The SRF combines high energy surge protection and electrical noise
reduction in a compact unit for new generation axle
counter counting head cables.
Optimised for use on the Siemens Clearguard ACM family of axle counters.

Air Gap Arresters


Datasheet Sh-01-01
Four types that meet or exceed all applicable AREMA specifications. Fourpart datasheet describing:
Clearviewair gap type with 16 discharge point electrodes designed
for use on low voltage signal circuits and 115 Vac power circuits
Heavy Duty Clearviewair gap type with 16 discharge point
electrodes; has a higher surge current capability than the Clearview
Heavy Dutyfull air gap type for use on track circuits or where
extremely high surge currents are experienced
Clear-Commair gap type with 16 discharge point electrodes designed
for use on communication circuits
Available with protective caps and on porcelain bases with terminal studs.

Clear-Comm Lightning Arresters


Datasheet Sh-01-05
See datasheet for ordering information.

56

Siemens Rail Automation Pty Ltd 2014. All rights reserved.

11

ACCESSORIES
11.3

Resistors

Heavy Duty Equalisers


Datasheet Sh-02-01
A closed circuit shunt type protector for use on up to 24 Vdc circuits.
Maintains its 1000 minimum resistance and rated breakdown voltage
over a long service life.
A sealed version is available for use on equipment subject to moisture or
immersion. Although surge handling capability is not as great as the Heavy
Duty Equaliser, resistance remains constant in the presence of moisture.

11.3 Resistors
Sealed Resistors
Datasheet Sj-01-01
Made with alloy resistance wire wound on a porcelain core to which
stainless steel lugs are attached. The assembly is embedded in insulating
ceramic cement and a steel casing which is sealed with a high grade
insulating paint.
Can be used as heating units within some equipment to prevent frost
accumulation at vital points such as commutators to contacts.
All units are 100% tested for resistance and each unit is guaranteed to
have a nominal value not less than the rated value. Units are noted in
AREMA wattage specified in Manual Part 135. Maximum rise of hottest
temperature part of resistor body is 147C above ambient.

Resistance UnitsAdjustable, Fixed


Datasheet Sj-02-01
These units provide a sliding contact with resistance gradations.
All units are 100% tested for resistance and each unit is guaranteed to
have a nominal value not less than the rated value. Units are noted in
AREMA wattage specified in Manual Part 135. Maximum rise of hottest
temperature part of resistor body is 55C above ambient.

11.4 Tools
Insulated Terminal Wrenches
Datasheet 11F-1
For BSW, M6, 2 BA, M5 railways signal terminal nuts. Zinc plated
steel body embedded in a moulded plastic handle.

Short-Form Catalogue

Issue 26.0

57

11

11
11.4

ACCESSORIES
Tools

Relay Tag Crimping Tool


For crimping one or two wires into a Q crimp.

Contact Removal Tool

Barrier Mechanism Toolkit


Datasheet 11F-4
A set of tools that simplify setting up models S, SM, S-20, S-40, S-60 and
SMB barrier mechanisms using an easier method than the conventional
spring scale for both horizontal and vertical torque measurements.
Includes:
torque wrench
ratchet tools for manually raising the barrier
special hex key for adjusting the cams

Track Circuit Short Finder

...Improved

Datasheet 11F-5
Locate track circuit shorts quickly with this easy-to-use meter and purposedesigned probes.
Can also be used:
to locate high resistance bonds and track connections, noisy air gap
arrestors etc
as an insulated joint tester
for local ballast condition measurements

12

58

SECTION 12 IS NOT IN USE.

Siemens Rail Automation Pty Ltd 2014. All rights reserved.

13

SERVICES

13.1

Training

13. Services
13.1 Training
Railway Signalling Training
Datasheet 13A-1
Use our Training Department for cost-effective professional training.
Choose from over 120 courses to meet your organisations needs.

13.2 Technical Documentation


Technical Documentation Services
Reduce the potential for costly errors and increase your staffs
effectivenessengage our rail-experienced technical documentation
team to make your information more easily used.
Choose from various formats, including:
flowcharts
work instructions
maintenance manuals
quick reference cards

13.3 Refurbishments and Design


Q Relay Refurbishment
Datasheet 13B-4
Q relays restored to original specification for around 60% of the cost of
a new relay
QA certificate supplied
Full 12-month warranty
Contacts, pivot plates and covers replaced to latest specification where
necessary and compatible
Fast turnaround supports use for stageworks and spares
Most brands and models

Short-Form Catalogue

Issue 26.0

59

13

13
13.3

SERVICES
Refurbishments and Design

Electro-mechanical Refurbishment
Datasheet 13B-1
Return your worn-out equipment to Invensys Rail for partial or complete
refurbishment.

Point Layouts
Datasheet 13B-3
We have over 250 standard, proven and approved designs on file for just
about every point machine whether pneumatic, hydraulic or electromechanicaland every point layout. We have design approval with all
major Australian and some overseas Railways. Standard designs are all
field proven. So chances are we have your solution already.
Save valuable time and reduce risks by using installation kits from the
point experts. One order provides everything needed for an installation so
you dont have to manage design, ordering, order chasing, kitting etc.

60

Siemens Rail Automation Pty Ltd 2014. All rights reserved.

Siemens Rail Automation Pty Ltd


ABN 78 000 102 483
380 Docklands Drive
Docklands
Victoria 3008
Australia

T
F
E
W

+61 1300 724 518


+61 3 9616 9001
rail-components.au@siemens.com
http://www.siemens.com.au/rail-components

Vous aimerez peut-être aussi