Académique Documents
Professionnel Documents
Culture Documents
S.NO.
DESCRIPTION
TYPE
MAKE
PRICE
I/C-2
B/C O/G-1
FEEDERS
O/G-2
QTY
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
REMARKS
I/C-1
S.NO.
DESCRIPTION
TYPE
MAKE
PRICE
I/C-2
B/C O/G-1
FEEDERS
O/G-2
QTY
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
REMARKS
I/C-1
S.NO.
DESCRIPTION
TYPE
MAKE
PRICE
I/C-2
B/C O/G-1
FEEDERS
O/G-2
QTY
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
REMARKS
STSPL/DET/QTN/859/14-15
01-10-14
BILL OF MATERIAL
QTY
S.NO
1
2
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
DESCRIPTION
11kV 800A 20kA Vacuum Circuit Breaker
Shunt opening & Closing coil voltage -24VDC
11kV 150/1-1A Current Transformers
Core-1: Class-0.5; Burden-15VA
Core-2: Class-5P10; Burden-15VA
11kV 150/1-1A Current Transformers
Core-1: Class-0.5; Burden-15VA
Core-2: Class-5P10; Burden-15VA
11kV Potential Transformers (11kV/3/110/3V)
Class-0.5; Burden-15VA
VF - 1.2 Cont. & 1.5 for 30 sec
33kV PT Fuses; 3.15A
Ammeter with selector switch
Voltmeter with selector switch
Multifunction Meter
3 Over Current + 1 Earth Fault Relay
Master Trip Relay
Auxiliary Relays
Annunciator - 8 Window
Hooter
Indication Lamps
Push Button
16A 10kA DP MCB
6A 10kA DP MCB
6A 10kA SP MCB
Control Fuses; 20A base/4A fuse link
Breaker control switch
Space heater
Thermostat; (25-75) deg C
Power Socket; 230V/5A; 3-Pin
Local/Remote selector switch; 2-way
Control relays; 24V DC
1
I/C
MAKE
PRICE
2
O/G-1
T/F
FEEDERS
ABB
175000
15000
15000
15000
1250
1250
8500
20000
3000
6000
6500
850
150
175
328
328
113
100
1200
250
200
150
250
350
3
1
1
1
1
1
1
10
1
2
2
2
3
1
1
2
1
1
0
2
2
4
2
2
14
2
4
4
4
6
2
2
4
2
2
0
TOTAL
FABRICATION
GRAND TOTAL
TYPE - INDOOR
REV_01
STSPL/DET/QTN/859/14-15
01-10-14
QTY
REF.
3
3
A
B
C
3
3
1
1
3
3
4
2
3
24
3
6
6
6
9
3
3
6
3
3
0
E1
E2
E3
F1
F2
F3
G1
G2
G3
G4
H1
H1
H1
H2
H3
H4
525000
0
45000
0
0
90000
0
0
45000
0
0
3750
1250
8500
60000
9000
24000
13000
2550
3600
525
1968
1968
678
900
3600
750
1200
450
750
0
843439
843439
REV_01
DESCRIPTION
A
1
VCB
Standards
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
B
1
VCB ACCESSORIES
Shunt opening release (-MO1)
Control Voltage
Operating limits
Opening time
Power on inrush
Inrush duration
Continuous power
Insulation voltage
Operating limits
Power on inrush
Rated Power
Inrush duration
Charging time
Insulation voltage
C
CURRENT TRANSFORMERS
Standard
Type
Designation
Rated Voltage
Highest Voltage
Power frequency withstand voltage (primary)
Power frequency withstand voltage (secondary)
Impulse withstand voltage
Rated primary current
Rated secondary current
No. of cores
Class of accuracy - Core-1
Class of accuracy - Core-2
Class of accuracy - Core-3
Burden - Core-1
Burden - Core-2
Burden - Core-3
Knee point voltage
Short Time withstand current
Insulation class
VOLTAGE TRANSFORMERS
Standard
Type
Designation
Rated Voltage
Highest Voltage
Power frequency withstand voltage (primary)
Impulse withstand voltage
Rated primary voltage
Rated secondary voltage
No. of cores
Class of accuracy - Core-1
Class of accuracy - Core-2
Burden - Core-1
Burden - Core-2
Voltage Factor
Insulation class
E
1
METERING
Digital Ammeter - Site programmable
Accuracy Class
Type
Selector switch
2
F
1
PROTECTION
4-Pole; 3Over current & Earth fault relay
Type
ANSI Code
High set
Settings range
Communication
Selectable curves
CT secondary
Control Voltage
Auxiliary Relays
Type
ANSI Code
Voltage band
Operating time
Burden
Output contacts
Control Voltage
G
1
INDICATION / ANNUNCIATION
Annunciator
No. of Windows
Supply voltage
ANSI Code
Power Consumption
Hooter / Buzzer
Audio Output
Supply voltage
Burden
Indication Lamps
Breaker 'On' Indication lamp
Breaker 'Off' Indication lamp
Breaker 'Trip' Indication lamp
Breaker 'Spring charge' Indication lamp
Trip circuit healthy' Indication lamp
Space heater 'On' Indication lamp
DC supply 'On' Indication lamp
R' Phase Indication Lamp
Y' Phase Indication Lamp
B' Phase Indication Lamp
Push Button
Trip circuit healthy push button
H
1
CONTROL
Miniature Circuit Breakers (MCB)
16A 10kA DP MCB
16A 10kA DP MCB
6A 10kA DP MCB
6A 10kA DP MCB
6A 10kA SP MCB
6A 10kA SP MCB
Control Fuses
20A Fuse base with 2A Fuse link
UNIT/MAKE
Vmax
IEC 62271-100
CEI EN62271-100
Vacuum
12
12
28
75
50 - 60
800
ABB
Ur [kV]
Us [kV]
Ud (1 min) [kV]
Up [kV]
fr [Hz]
Ir [A]
20
Isc [kA]
20
50
[O - 0.3" - CO - 15" - CO]
33.5 ... 60
10 ... 15
43.5 ... 75
45 ... 80
150
98
-5 ... +40
IEC: 60068-2-30, 60721-2-1
IEC 62271-1
4NO+4NC
Ik [kA]
Ip [kA]
Vmax
ABB
24
65 - 120% Un
33.5...60
< 150
150
3
2000 (for 1 min)
Un (V DC)
24
65 - 120% Un
45...80
< 150
150
3
2000 (for 1 min)
Un (V DC)
230
Un (V AC)
ms
ms
ms
ms
mm
kg
[C]
ms
Ps (W)
ms
Pc (W)
V
ms
Ps (W)
ms
Pc (W)
V
85 - 110 % Un
600
200
0,2 s
6-Jul
2000 (for 1 min)
RESIN CAST
IS 2705
Bar
Resin cast indoor
11
12
28 (1min)
3 (1min)
75
150
1
3
0.5
5P10
PS
15
15
15
--13.1
B
Ps (VA)
Pn (VA)
s
s
V
STRATON
kV
kV
kV (rms)
kV (rms)
kV (peak)
A
A
Metering
Protection
Differential
VA
VA
VA
--kA
---
RESIN CAST
IS 3156
Bar
Resin cast indoor
11
12
28 (1min)
75
11000/3
110/3
2
0.5
3P
50
50
1.2 Cont. & 1.5 for 30 sec
B
STRATON
Alpha+ A / Equ.
1
Single phase
Elmeasure / Equ.
kV
kV
kV (rms)
kV (peak)
V AC
V AC
--Metering
Protection
VA
VA
-----
3-way
Alpha+ V / Equ.
1
Single phase
3-way
LG5310 / Equ.
1
VLL, VLN, A, Hz, W,VA, PF, Wh
----
Salzer
Elmeasure / Equ.
Ashida / Equ.
Salzer
Elmeasure / Equ.
V DC
VAJH13
Electromagnetic
86
50 to 120% of rated voltage.
10 milliseconds nominal
4
2 N/O + 2 N/C
24
Alstom
VAX31
Electromagnetic
95
Continiously(both pre & post closure)
80% - 120% of rated voltage.
0.35 to 0.8
0.52 / 0.37
1N/O + 2N/C
24
Alstom
VAX33
Electro-magnetic
49/63
75%-120% of rated voltage.
15 - 20
3 per element
2N/O + 2N/C
24
Alstom
W
V DC
s
W
V DC
ms
W
V DC
MLD 02
8
18 - 90
30
< 0.5 /window
Alan / Equi.
AUH01
100dBA approx.
18 - 285
< 15
Alan / Equi.
Red
Green
Amber
Blue
White
Red
Red
Red
Yellow
Blue
V DC
W
V DC
Ma
Esbee (L&T)
24V DC
24V DC
24V DC
24V DC
24V DC
24V DC
24V DC
110V AC
110V AC
110V AC
Esbee (L&T)
White
5SX / Equ.
DC Control
220V AC Control
Closing/Tripping & Indication circuit
Protection relay circuit
Plu & Socket
Thermostat & Space heater
Siemens / Equ.
C Curve
C Curve
C Curve
C Curve
C Curve
C Curve
3NW / Equ.
PT Secondary protection
Siemens / Equ.
25 / 32
660
Spring return
60 / 45
SSBS
3Phase 4-wire screw type
Back
50 @50 deg C
Kaycee / Equ.
A
V
deg
DAV
DESCRIPTION
A
1
VCB
Standards
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
B
1
VCB ACCESSORIES
Shunt opening release (-MO1)
Control Voltage
Operating limits
Opening time
Power on inrush
Inrush duration
Continuous power
Insulation voltage
Power on inrush
Rated Power
Inrush duration
Charging time
Insulation voltage
C
CURRENT TRANSFORMERS
Standard
Type
Designation
Rated Voltage
Highest Voltage
Power frequency withstand voltage (primary)
Power frequency withstand voltage (secondary)
Impulse withstand voltage
Rated primary current
Rated secondary current
No. of cores
Class of accuracy - Core-1
Class of accuracy - Core-2
Class of accuracy - Core-3
Burden - Core-1
Burden - Core-2
Burden - Core-3
Knee point voltage
Short Time withstand current
Insulation class
VOLTAGE TRANSFORMERS
Standard
Type
Designation
Rated Voltage
Highest Voltage
Power frequency withstand voltage (primary)
Impulse withstand voltage
Rated primary voltage
Rated secondary voltage
No. of cores
Class of accuracy - Core-1
Class of accuracy - Core-2
Burden - Core-1
Burden - Core-2
Voltage Factor
Insulation class
E
1
METERING
Digital Ammeter - Site programmable
Accuracy Class
Type
Selector switch
F
1
PROTECTION
4-Pole; 3Over current & Earth fault relay
Type
ANSI Code
High set
Settings range
Communication
Selectable curves
CT secondary
Control Voltage
Auxiliary Relays
Type
ANSI Code
Voltage band
Operating time
Burden
Output contacts
Control Voltage
F
1
INDICATION / ANNUNCIATION
Annunciator
No. of Windows
Supply voltage
ANSI Code
Power Consumption
Hooter / Buzzer
Audio Output
Supply voltage
Burden
Indication Lamps
Breaker 'On' Indication lamp
Breaker 'Off' Indication lamp
Breaker 'Trip' Indication lamp
Breaker 'Spring charge' Indication lamp
Trip circuit healthy' Indication lamp
Space heater 'On' Indication lamp
DC supply 'On' Indication lamp
Push Button
Trip circuit healthy push button
G
1
CONTROL
Miniature Circuit Breakers (MCB)
16A 10kA DP MCB
16A 10kA DP MCB
6A 10kA DP MCB
6A 10kA DP MCB
6A 10kA SP MCB
6A 10kA SP MCB
Control Fuses
20A Fuse base with 2A Fuse link
UNIT/MAKE
Vmax
IEC 62271-100
CEI EN62271-100
Vacuum
12
12
28
75
50 - 60
800
ABB
Ur [kV]
Us [kV]
Ud (1 min) [kV]
Up [kV]
fr [Hz]
Ir [A]
20
Isc [kA]
20
50
[O - 0.3" - CO - 15" - CO]
33.5 ... 60
10 ... 15
43.5 ... 75
45 ... 80
150
98
-5 ... +40
IEC: 60068-2-30, 60721-2-1
IEC 62271-1
Ik [kA]
Ip [kA]
Vmax
ABB
24
65 - 120% Un
33.5...60
< 150
150
3
2000 (for 1 min)
Un (V DC)
24
65 - 120% Un
45...80
< 150
150
3
2000 (for 1 min)
Un (V DC)
230
85 - 110 % Un
Un (V AC)
ms
ms
ms
ms
mm
kg
[C]
ms
Ps (W)
ms
Pc (W)
V
ms
Ps (W)
ms
Pc (W)
V
600
200
0,2 s
6-Jul
2000 (for 1 min)
Ps (VA)
Pn (VA)
s
s
V
RESIN CAST
IS 2705
Bar
Resin cast indoor
11
12
28 (1min)
3 (1min)
75
150
1
3
0.5
5P10
PS
15
15
15
--13.1
B
STRATON
kV
kV
kV (rms)
kV (rms)
kV (peak)
A
A
Metering
Protection
Differential
VA
VA
VA
--kA
---
RESIN CAST
IS 3156
Bar
Resin cast indoor
11
12
28 (1min)
75
11000/3
110/3
2
0.5
3P
50
50
1.2 Cont. & 1.5 for 30 sec
B
STRATON
Alpha+ A / Equ.
1
Single phase
3-way
Elmeasure / Equ.
kV
kV
kV (rms)
kV (peak)
V AC
V AC
--Metering
Protection
VA
VA
-----
Salzer
Alpha+ V / Equ.
1
Single phase
3-way
LG5310 / Equ.
1
VLL, VLN, A, Hz, W,VA, PF, Wh
----
Elmeasure / Equ.
Ashida / Equ.
Salzer
Elmeasure / Equ.
V DC
VAJH13
Electromagnetic
86
50 to 120% of rated voltage.
10 milliseconds nominal
4
2 N/O + 2 N/C
24
Alstom
VAX31
Electromagnetic
95
Continiously(both pre & post closure)
80% - 120% of rated voltage.
0.35 to 0.8
0.52 / 0.37
1N/O + 2N/C
24
Alstom
VAX33
Electro-magnetic
49/63
75%-120% of rated voltage.
15 - 20
3 per element
3N/O + 1N/C
24
Alstom
W
V DC
s
W
V DC
ms
W
V DC
MLD 02
8
18 - 90
30
< 0.5 /window
Alan / Equi.
AUH01
100dBA approx.
18 - 285
< 15
Alan / Equi.
Red
Green
Amber
Blue
White
Red
Red
V DC
W
V DC
Ma
Esbee (L&T)
24V DC
24V DC
24V DC
24V DC
24V DC
24V DC
24V DC
Esbee (L&T)
White
5SX / Equ.
DC Control
220V AC Control
Closing/Tripping & Indication circuit
Protection relay circuit
Plu & Socket
Thermostat & Space heater
Siemens / Equ.
C Curve
C Curve
C Curve
C Curve
C Curve
C Curve
3NW / Equ.
PT Secondary protection
Siemens / Equ.
25 / 32
660
Spring return
60 / 45
SSBS
3Phase 4-wire screw type
Back
50 @50 deg C
Kaycee / Equ.
A
V
deg
DAV