Vous êtes sur la page 1sur 6

Fluke430SeriesIIFirmwareUpgrade

WiththisFlashToolyoucanupgradethefirmwareoftheFluke430SeriesIIPowerQuality
AnalyzerV03.01andlatertoV05.00.

ItisrecommendedtomakeacopyoftheSDCardpriortoupgradingthefirmware.
AfterarchivingtheSDCardfiles,youmaydeletethefilesfromtheSDCard.
FirmwareV05.00canreadmeasurementdatacreatedwithpreviousversionsofthefirmware.
FirmwareV05.00iscompatiblewithPowerLogV5.2

ItisrecommendedtouseUSB2.0portsonlyforthefirmwareupgrade.Instrumentswithserial
numberpriortoS/N33363001donotsupportUSB3.0.Iftheupgradefails,theunitmaylose
functionalityorcalibrationstatus.

Versionhistory:
V05.00ImprovementscomparedtoV04.05
AddedMotorAnalyzerfunctionforFluke438II.TheMotorAnalyzerfunctionisoptional
(Fluke430II/MA)forFluke434II,Fluke435IIandFluke437II.
ImprovedEnergyLossCalculator.Lossesduetoloadcurrentandlossesduetosource
voltagearemeasuredanddisplayedseparately.Anewanalyzerscreenshowstheloss
relativetothepositivesequencepower(anoptimalsystemonlypositivesequencepoweris
present)
ReplacedEnergyLossCalculatorAutomethodwithFuseValuemethodforimproved
calculationofenergyloss.
ExtendedEnergyLossCalculatorwithCableResistancemethodforcalculatingenergy
loss.
ExtendedEnergyLossCalculatorsetupwithextrapolationsetting:hour,day,weekoryear
CorrectedEnergyLossCalculatortouseabsolutesumofphasepowersfortotalpower
AddedVdcandAdcmeasurementstoLoggermode
Correcteddelta(3wire)configurationtoshowkVAfund+insteadofkVA
Improvedpowermeasurementsfordelta(3wire)configurationbyusingavirtualstar
insteadofusingthe2Wattmetermethod
SeveralUIimprovements
FixeddatepropertyforfilesonSDCard
ImprovedbandwidthresponseforVrmsmeasurements
CorrectedOverLoadindicationforPhasorandHarmonicsscreens
CorrectedCrestFactorOverLoadindication
CorrectedInrushCurrentmeasurementtomeasurebetweenmarkers
CorrectedUnbalancemeasurementwhenusingscalingforcurrentinputs
FixedissueswithBatteryInformationscreen

Versionhistory:
V04.05ImprovementscomparedtoV04.04(versionV04.04wasnotusedforproduction)
IncreasedspeedforSDCardformattingprocessbyremovingtestcycle
FixedissueswithlosingclampsettingsafterpowerOFF
Improvedsavingmeasurementdatawhenopeningbatterydoor


V04.04ImprovementscomparedtoV04.02(versionV04.03wasnotreleased)
ImprovedwritingprocesstoSDCardtopreventfromfilesthatcannotbeopened
FixedseveralUIissueslikewhitespotsonscreen,scalingandtrendgraphdisplay
FormattingSDCardsnowincludesatestofthecardwritespeed,duetothis,formatting
cantakeupto10minutes
RemovedUnbalancemeasurementfromsinglephaseITmeasurements
Fixedissueswithincorrectcursortimeforevents
FixedissueswithtimestampsforWaveEventandRMSEvent
FixedTimedmeasurementforInrush.NowInrushcanusedifferentdurationtime
Improvedpoweronbehavior.OncetheinitialPoweronWizardisfilledout,thesettingsare
storedandonlyresetwhenselectingfactorydefaultsontheinstrument.
FixedissueswithEnergyLossCalculatornowshowingtheselectedcurrencycorrectly
AddedTimedmeasurementforTransientsmode
Addedwarningtoturntheinstrumentoffwhenthebatterydoorisopened
FixedenteringnominalvoltageforHLegconfiguration.Nowthephasetophasevoltage
mustbeentered
FixedissuewithmeasurementsnotstartingwithoutSDcard
DisabledPowerOffkeywhilemeasurementisrunning
Fixedissueswhentryingtosavemorethan100screens
CorrectedHarmonicsfundamentalvoltagefor3phaseDeltaconfigurationtoshowphaseto
phaseinsteadofphasetoneutralvoltages
AddedPstandZerosequencevoltageUnbalancetoMonitormodetosupportGOST32144
AddedlimittemplateGR32144fortestingaccordingtoGOST32144
Correctedissueswhenautomaticallysavingfilesifbatteryrunsempty
CorrectedclearingoftheflaggingstatusforFlickerafteranevent
Resolvedissueswithwhitescreenafterpoweron
Fixedissuewithincorrectindicationofmaximumrecordingduration
FixedunjustUnbalanceOL(overload)indicationforL3,L2,L1/C,B,Aphasesequence
FixedclippingproblemsforTotalPower
FixedbehaviorofKeyboardLockfunctioninterferingwithSavemessagepopupwhen
measurementsareautomaticallystopped
ReducedthenumberoffileswrittentoSDcardtoimprovewritespeedperformance
Extendedvoltageratiosettingstosupportupto999kV
Measurementdatafilesareextendedwithsystemstatuslike:batterycondition,
temperature,memorystatus,anderrorconditions
Addedwarningmessagewhenpressingthepowerbuttonwhilekeyboardlockisenabled
Demomodeisautomaticallydisabledatpowerofftopreventfromusingitbymistake
Savedscreensarealsostoredasimages(.BMP)ontheSDcardforuseby3rdparty
applications
Improvedautomaticshutdownonlowbatterytoassurefilesareclosedcorrectly.
FixedissuewithnonrespondingpreparingSDCardmessagewhenrestartingMonitor
measurements
FixedissueswithavailablerecordingtimeindicationinLoggerstartmenu

Versionhistory:

V04.02ImprovementscomparedtoV04.01
OptimizedSDcardwriteprocesstopreventfromwriteerrorsonslowrespondingSDcards

Versionhistory:
V04.01ImprovementscomparedtoV04.00
Removedphasetophasevoltageinsplitphaseconfiguration
AutomaticallytriggeronAmpsthresholdinInrushmodetocaptureeventdetails
DifferencebetweenVrmsresultonscreenandviainterfaceintransientsmoderesolved
WaveEventtimestampscorrectedfor400Hz
TranslationissueswithRussianFontresolved
LoadUnbalanceparametersremovedfromLoggerselectionlist
Resetissueresolvedwhenpressingpoweroffbuttoninsavedialogwindow
Resolvedissueswithinstrumentnotstarting.
Fixedissueswith0EventsandRMSWAVEEventkeyshowingstrangedata
FallingedgeofDIPnotshowninRMSandWaveEVENTtab
FixedissuewithMonitortrend,notabletomovecursortothenewestpixelonscreen
FixedissueswithvoltagereadingsforLoggerdeltaconfiguration
ImproveddatadownloadviaUSB
FixederroneouspowerreadingsforsinglephaseITconfiguration
FixedSDcarderrorwhendownloadingmeasurementwitheventon434II
Fixedissueswhenmorethan9999eventsoccur
ImproveEnergyLossCalculatorlayout
Resolvedinstrumentcrashduetoaspecificinputsignal
Improvedfontfor"KVAfund"
IEEEpowershowsmoredatathanUnified
AddedPFreadingtoIEEEpowermeasurementmode
FixedLeading/LaggingindicatorforIEEEpowermeasurementmode
RemovedpowermethodindicationfromEnergyLossCalculatorfunction
FixedcorruptingSDcardwhenturningoffinstrumentduringdelete
FixedFlickermeasurementresults
FixeddoublereadingsofVAunbalreadingslist
FixedPFmissingtrendwhenIEEEcalculationmethodisselected
FixedRMSmissingeventtrendinDELTAmode
Fixedcursormovementtotherightofscreen
Removedreadingatneutralforsinglephasewithoutneutralconfiguration
FixedPFandDPFduplicates
FixedtrendsdisplayforPFandCosPhiinIEEEpowermeasurementmode
ImprovedEnergyLossmeasurementforresidualpowerloss
FixedpowerreadingsforsinglePhaseITconfiguration
FixedIEEEPowerreadingsfordeltaconfiguration
Fixedrandomshutdownofinstruments
FixedPhasordiagramfordeltaconfigurationandleftturningphasesequence
FixedincorrectapparentpowercalculationinsinglePhaseITconfiguration(noneutral)
FixedSplitPhaseapparentpowercalculation
FixedEfficiencyFactorandHarmonicPollutionreadingsforPowerLog
ImprovedOLdetectionandextendedphasetophasereadingabove1000V


V04.00ImprovementscomparedtoV03.08
Fixedissueswithtimestamps
CorrecteddurationofMonitormeasurement
Improvedhandlingofeventsstartingpriortothemeasurement
Improvedhandlingofeventsthatendedafterthemeasurementwasfinished
DefaultfilenameshortenedtoMEASx
Correctedsettingforaveragingtime
FixedchangingsettingswhileinHOLD
FixedissueswitheventsinMonitormode
AddedsupportforEnergyLosscalculationonaluminumcables
AddedsupportforpowermeasurementsaccordingtoIEEE14592010
Fixedissueswithfirmwarecrashwhenmultipleeventsoccurredduring10minutesync
FixedreferenceselectionforDips&Swellsinsetupmenu
CorrectedcalculationoffirstPltreading
AddedsupportforbackupandrestoreoftasksusingPowerLog4.0
AddedsupporttodisplaymeasurementspecificinformationinPowerLog
CorrectedRussianfont
Improveddigitscrollinginmenus
Fixedissueswhenrecallingmeasurementwithemptybattery
FixedissueswhenrecallingEnergyLossmeasurements
FixedissueswhenrecallingPowerWavemeasurements
FixedSDCARDERROR1:9:5fordownloadviaUSB
FixedissueswithdownloadingscreensviaUSB
UnbalancePowerreadingsremovedwhenusingClassicPowermeasurementmethod
Recordinglengthislimitedtomatchaveragingtimeandnumberofreadingsselected

V03.08ImprovementscomparedtoV03.07
Nofunctionalchanges.VersionV03.08wasreleasedtosupportanewhardwareboard
revision

V03.07ImprovementscomparedtoV03.06
ResolvedissueswithSDcardfullerrormessagewhenselectingMonitorafterpowerOn
AddedtestcommandsforLoggermodefortesting10/12cyclestimestampwithms
resolutiontoverifyIEC61000430timesyncrequirements

V03.06ImprovementscomparedtoV03.05
AddedsupportforEN50160reportgenerationwithPowerLog3.4
Addedfunctionalitytodiscardmeasurements
Addedfunctionalitytorenamemeasurementswhensaving
Improveddigitscrollingwhenenteringvaluesusingcursorkeys
Addedfunctionalitytoresumeameasurementwhenpowerreturnsaftershutdownonlow
batterywhilemeasuring
Reducedthenumberofdefaultselectedparametersinlogger
EventtriggeringonAMPthresholdselectedbydefaultwhenusingInrushfunction
FixedVrmsmin,avgandmaxvaluesnotmatchingcursorvalues

FixedCursormismatchatinrushtrend
AddedmillisecondresolutiontimestamptoQBremotecommand
Fixedloggercrashwith150parametersand250msintervaltimesetting
Fixedmissingrighttrendpixelsiin250msand0.5strendmode
Fixedissueswith32GBSDcard
Fixedloggermaximumdurationerror

V03.05ImprovementscomparedtoV03.04
SupportnewFluke437IIPowerQualityandEnergyAnalyzer400Hz
Added400HzmeasurementsforFluke437II
AddedShipboardfunctionforFluke437II
Correctedseveraltranslations
Defaultaveragetimechangedfrom1sinto10s
Readingsonmeterscreensarerestoredafterrecall
Harmonicsbargraphsandreadingsarerestoredafterrecall
ImprovedPowerLogcommunicationspeed
AddedPowerWavewaveformsupportforPowerLog
Improvedcommunicationrobustness
AddedsetupinformationforPowerLog
AddedscalinginformationforPowerLog
FixedcursortimestampsforRMSevents
Fixedmissingunstableflaggingindicatorafterrecall
ImprovedharmonicphaseangleforFlexprobes
FixedmissingpowermeasurementinHlegconfiguration
FixedEnergyLossCalculatorcostalwaysshowingk0.0000
FixedTransienteventnocapturedinMonitor
CorrectedF4softkeylabelforclampsetuptoNEUTRALinsteadofTOTAL
FixedissuewithEnergyLossCalculatorwhenchangingcurrency
Fixedresetissuewhenturningoffdemomode
Fixedscalingforharmonicrmsvalues
Improvedtimingwaveevent
ChangedsetupAMPSSCALING"Range:"to"Clamprange:"
SeveralsmallUIimprovementsaremade

(V03.04)ImprovementscomparedtoV03.03
ResolvedPowerreadingserrorclippingto32767inTrendview

V03.03ImprovementscomparedtoV03.02
ResolvedtimingissueswithSDCardtopreventfromSDCarderrors
CorrectedalgorithmforMetCalBandwidthverification

V03.02ImprovementscomparedtoV03.01(V03.01isthe1strelease)
ImprovedSDCardstartup
CorrectedSetupFunctionPref.menuforChinese,Korean,CzechandPolishlanguage
CorrectedCzechcharacterset
Correctedseveralfontissuesduetohardspace

CorrectedmenutitleforVolts/Amps/HertzinRussianlanguage

GettingStarted:
EntertheserialnumberofyourinstrumentintheInstrumentDMdialogbox.
ConnectyourinstrumentusingUSBcable
ConfigurevirtualUSBCOMporttorangeCOM18ofyourPC
Selectthevirtualcomporttowhichtheinstrumentisconnected
ConnecttheinstrumenttomainspowerusingtheBC430BatteryCharger
Turnonyourinstrument
PresstheSTARTbuttontostarttheupgradeprocess
Whentheupgradeissuccessful,amessageisdisplayed.Notethatyourinstrumentwill
switchoffandonseveraltimesautomaticallyduringtheupgradeprocess.

Riskswhenupgradingfirmware!
UpdatingtheinstrumentfirmwareinvolvesoverwritingtheinternalFlashROMcodecurrently
storedontheinstrumentandreplacingitwithnewcode.Thisprocesshasthepotentialto
renderyourinstrumentuselessifthereisanerrororinterruptionwhiletheupdateisoccurring.
Thismayrequirereturningtheinstrumentforrepairatanominalfee.
FollowthestepsbelowpriortoselectingtheFlashToolSTARTbutton.
Validatethatthecommunicationlinkbetweenyourcomputerandtheinstrumentis
reliable.(Tip:UsethePowerLogsoftwaretotestthecommunicationandshowtheCOM
portthatisused)
Logontoyourcomputerwithanadministratoraccount
Closeallotherapplications
Closeapplicationsrunninginthebackground.Someofthemostcommonapplications
runninginthebackgroundthatareknowntointerfereareantivirussoftware,the
IntelliMouseapplication,andaudioplayers.Mostoftheseapplicationsappearinthe
SystemTrayontheDesktop.TocloseanapplicationthatappearsintheSystemTray,right
clickontheapplicationiconandlookforoptionstocloseordisabletheapplication

Iftheupgradefails:
Iftheupgradeisunsuccessful,sometimestheinstrumentisunabletostartproperly.Inthis
situationthedisplaywillnotswitchon,andonlyabeepindicatesthattheinstrumentison.
Turnonyourinstrumentwhileholdingthecursorupandcursorrightkeysandlistenforthesoft
beep.Nowrestarttheupgradeprocess.TheFlashToolwillrecognizethattheprevious
installationfailed,andrecovertheinstrumentdataautomatically.Releasethecursorkeysonce
theupgradeprocesshasstarted.
Inotherraresituationstheinstrumentwillturnononlybrieflyandshutdownautomatically.If
thisisthecase,removingthepowercordandbatteryfor5to10minutesresolvestheissueasit
clearstheRAMmemoryoftheinstrument.

FlukeIndustrialApril20,2016