Vous êtes sur la page 1sur 1

DROP-OFF

LOBBY

LOBBY

PANTRY

1700

1700

1600

1700

D1

D2

D3

D5

1600

1600

1500

1600

LEVER
HANDLE

50 MM
DEP.

D4

D6

920

900

CONFERENCE

CARPORT

HALLWAY

HALLWAY

1600

1600

1500

900

1600

800

800

800

750

ENERGY WORLD
CORPORATION LTD.

900

LOBBY

800

990

CARPORT

10

750

800

800

D2

LOBBY

FRAMELESS
LOCATION:
D3

CONFERENCE ROOM

1600

NO. OF SET:

NO. OF SET:

LEVER
HANDLE

900

PANTRY

D8

DOOR

NO. OF SET:

VARIES
4 EQ. SPACES

VARIES
2 EQ. SPACES

SW 1
1985

40 620 40

2200

700
1500

1000
18

LOBBY

1200

NO. OF SET:

AW 1
700

FFL

LOCATION:
STORAGE ROOM @ GROUND FLOOR
AND SECOND FLOOR
NO. OF SET:

2100

2100
2425

2800

1500

2200

40

2200

40

NO. OF SET:

SW 2

NO. OF SET:

FCL

FFL

LOCATION:

900

DOOR

D12

ROOF DECK

900

NO. OF SET:

AW 2
1400

LOCATION:
PANTRY @ GROUND FLOOR
AND SECOND FLOOR
NO. OF SET:

FCL

2425

1985
VARIES
4 EQ. SPACES

40

FFL

40

40
712

LOCATION:
CONFERENCE ROOM, SECURITY OFFICE
ELECTRICAL PANEL ROOM, GENERAL OFFICE

LOCATION:
STEEL

FIRE EXIT

VARIES
2 EQ. SPACES

FFL

DOOR

SLIPFORM
ENGINEERING
INTERNATIONAL (HK) LTD.

7650

700

1120

1200

40
1120

1200
1000

NO. OF SET:

1400

FFL

D11

JANITOR'S ROOM

600

LOCATION:
STEEL

1120

1200

DOOR

FCL

40

1985

2200

NO. OF SET:

FCL

FCL

FFL

D10

TOILET

F.F.L.

LOCATION:STEEL

800

FCL

DOOR

D9

900

NO. OF SET:

F.F.L.

STEEL
LOCATION:

STORAGE ROOM

820

ELECTRICAL ROOM

900
IMPORTANT NOTES:
- COORDINATE WITH OTHER TRADES
- VERIFY ACTUAL CONDITION ON SITE AND FIT DETAILS
ACCORDINGLY.

F.F.L.

STEEL
LOCATION:

40

DOOR

2100

F.F.L.

ROOF DECK

2100

2100
F.F.L.

HALLWAY

ENERGY WORLD CORP. LTD.

900

FIRE EXIT
DEVICE

LEVER
HANDLE

HALLWAY

IMPORTANT NOTES:
1. STAKING OF COLUMNS, BEAMS, AND SLABS SHALL BE COORDINATED AND VERIFIED WITH
ARCHITECTURAL PLANS AND DETAILS. DIMENSIONS SHOWN ON STRUCTURAL PLANS ARE FOR
DESIGN PURPOSES ONLY. CONSTRUCTION LAYOUT SHOULD FOLLOW ARCHITECTURAL
ALIGNMENTS. SHOULD CONFLICT OCCUR BETWEEN STRUCTURAL AND ARCHITECTURAL PLANS,
REFER THE MATTER TO THE ARCHITECT FOR FINAL DECISION AND APPROVAL.
2. COORDINATE WITH OTHER TRADES.
3. VERIFY ACTUAL CONDITION ON SITE.

HALLWAY

PAGBILAO LNG HUB TERMINAL


AND POWER STATION - PLANT
CONTROL AND ADMIN BUILDING

NON-HANDED
DOOR CLOSER

900

80

LEVER
HANDLE

LEVER
HANDLE

D12

900

NON-HANDED
DOOR CLOSER

670

600

VIEWING
DECK

FIRE EXIT
STAIRWELL

D10

870

800

NO. OF SET:

40

ELECTRICAL
ROOM

D7

NO. OF SET:

900

D9

970

SECURITY OFFICE

900

D11

50 MM
DEP.

DOOR

D6

2100

D8

STEEL
LOCATION:

1600

NON-HANDED
DOOR CLOSER
NON-HANDED
DOOR CLOSER

GLASS DOOR

OPERATOR WORK STATION

JANITOR'S
ROOM

TOILET

900

D5

PANTRY
NO. OF SET:

STORAGE

900

FRAMELESS
LOCATION:

900

D7

STEEL
LOCATION:

D4

LOBBY

1500

GLASS DOOR

2100

PANTRY

FRAMELESS
LOCATION:

F.F.L.

100

NO. OF SET:

GLASS DOOR

F.F.L.

2200

1600

GLASS DOOR

GD

320 40

FRAMELESS
LOCATION:

F.F.L.

2100

D1

F.F.L.

GD

400

GLASS DOOR

GD

700

FRAMELESS
LOCATION:

GD

2100
1700

F.F.L.

GD

2100

F.F.L.

GD

2100

GD

2100

GD

2100

2100

GD

40
1000

40
712

LOCATION:

LOCATION:

W1

W2

OPERATOR WORK STATION

7857X735

NO. OF SET:

ROOF DECK

1985

NO. OF SET:

3
SCHEDULE OF DOORS AND WINDOWS

NOTES:
1. THE SUMMARY OF DOORS, FINISH HARDWARES AND ACCESSORIES ARE
INDICATIVE DONE TO SERVE AS A GUIDE. VERIFY DRAWINGS FOR EXACT
AREAS OF APPLICATION. SHOULD THERE BE ANY DISCREPANCY WITH
THE DRAWINGS, VERIFY WITH THE ARCHITECT BEFORE PROCEEDING.
2. PROVIDE MASTER KEYING AND COORDINATE WITH THE BUILDING OPERATOR
LOCKSET FUNCTIONS FOR COMMON AREAS & BACK-OF-HOUSE AREAS
INCLUDING PIPE CHASES, AUXILLIARY ROOM & ELECTRICAL ROOM (VERIFY
WITH THE OWNER).

SCHEDULE OF DOORS AND WINDOWS


SCALE:

1:50M

3. ALL HARWARES WITH YALE, SCHLAGE, STANLEY BRAND SHOULD BE U.S. MADE.
ALL HARDWARES & ACCESSORIES W/ HAFELE BRAND SHOULD BE GERMAN
MADE. SAME HARDWARE BRAND FROM OTHER COUNTRIES WILL NOT BE
ACCEPTED.
4. DOOR FACE FINISH ALONG THE RESIDENTIAL UNITS HALLWAY OR PUBLIC
HALLWAY TO BE FINISHED BY INTERIOR DESIGNER (REFER TO I.D. DRAWINGS
& SPECIFICATIONS).
5. FOR FIRE EXIT DOOR EXIT DEVICE AT GROUND LEVEL, LEVER HANDLE LOCATED
AT PULL SIDE OF DOOR SHALL BE STOREROOM LOCK FUNCTION, SATIN
STAINLESS STEEL FINISH. GRADE 1 WITH ONE YEAR MINIMUM WARRANTY.

A:A7-02