Académique Documents
Professionnel Documents
Culture Documents
LOBBY
LOBBY
PANTRY
1700
1700
1600
1700
D1
D2
D3
D5
1600
1600
1500
1600
LEVER
HANDLE
50 MM
DEP.
D4
D6
920
900
CONFERENCE
CARPORT
HALLWAY
HALLWAY
1600
1600
1500
900
1600
800
800
800
750
ENERGY WORLD
CORPORATION LTD.
900
LOBBY
800
990
CARPORT
10
750
800
800
D2
LOBBY
FRAMELESS
LOCATION:
D3
CONFERENCE ROOM
1600
NO. OF SET:
NO. OF SET:
LEVER
HANDLE
900
PANTRY
D8
DOOR
NO. OF SET:
VARIES
4 EQ. SPACES
VARIES
2 EQ. SPACES
SW 1
1985
40 620 40
2200
700
1500
1000
18
LOBBY
1200
NO. OF SET:
AW 1
700
FFL
LOCATION:
STORAGE ROOM @ GROUND FLOOR
AND SECOND FLOOR
NO. OF SET:
2100
2100
2425
2800
1500
2200
40
2200
40
NO. OF SET:
SW 2
NO. OF SET:
FCL
FFL
LOCATION:
900
DOOR
D12
ROOF DECK
900
NO. OF SET:
AW 2
1400
LOCATION:
PANTRY @ GROUND FLOOR
AND SECOND FLOOR
NO. OF SET:
FCL
2425
1985
VARIES
4 EQ. SPACES
40
FFL
40
40
712
LOCATION:
CONFERENCE ROOM, SECURITY OFFICE
ELECTRICAL PANEL ROOM, GENERAL OFFICE
LOCATION:
STEEL
FIRE EXIT
VARIES
2 EQ. SPACES
FFL
DOOR
SLIPFORM
ENGINEERING
INTERNATIONAL (HK) LTD.
7650
700
1120
1200
40
1120
1200
1000
NO. OF SET:
1400
FFL
D11
JANITOR'S ROOM
600
LOCATION:
STEEL
1120
1200
DOOR
FCL
40
1985
2200
NO. OF SET:
FCL
FCL
FFL
D10
TOILET
F.F.L.
LOCATION:STEEL
800
FCL
DOOR
D9
900
NO. OF SET:
F.F.L.
STEEL
LOCATION:
STORAGE ROOM
820
ELECTRICAL ROOM
900
IMPORTANT NOTES:
- COORDINATE WITH OTHER TRADES
- VERIFY ACTUAL CONDITION ON SITE AND FIT DETAILS
ACCORDINGLY.
F.F.L.
STEEL
LOCATION:
40
DOOR
2100
F.F.L.
ROOF DECK
2100
2100
F.F.L.
HALLWAY
900
FIRE EXIT
DEVICE
LEVER
HANDLE
HALLWAY
IMPORTANT NOTES:
1. STAKING OF COLUMNS, BEAMS, AND SLABS SHALL BE COORDINATED AND VERIFIED WITH
ARCHITECTURAL PLANS AND DETAILS. DIMENSIONS SHOWN ON STRUCTURAL PLANS ARE FOR
DESIGN PURPOSES ONLY. CONSTRUCTION LAYOUT SHOULD FOLLOW ARCHITECTURAL
ALIGNMENTS. SHOULD CONFLICT OCCUR BETWEEN STRUCTURAL AND ARCHITECTURAL PLANS,
REFER THE MATTER TO THE ARCHITECT FOR FINAL DECISION AND APPROVAL.
2. COORDINATE WITH OTHER TRADES.
3. VERIFY ACTUAL CONDITION ON SITE.
HALLWAY
NON-HANDED
DOOR CLOSER
900
80
LEVER
HANDLE
LEVER
HANDLE
D12
900
NON-HANDED
DOOR CLOSER
670
600
VIEWING
DECK
FIRE EXIT
STAIRWELL
D10
870
800
NO. OF SET:
40
ELECTRICAL
ROOM
D7
NO. OF SET:
900
D9
970
SECURITY OFFICE
900
D11
50 MM
DEP.
DOOR
D6
2100
D8
STEEL
LOCATION:
1600
NON-HANDED
DOOR CLOSER
NON-HANDED
DOOR CLOSER
GLASS DOOR
JANITOR'S
ROOM
TOILET
900
D5
PANTRY
NO. OF SET:
STORAGE
900
FRAMELESS
LOCATION:
900
D7
STEEL
LOCATION:
D4
LOBBY
1500
GLASS DOOR
2100
PANTRY
FRAMELESS
LOCATION:
F.F.L.
100
NO. OF SET:
GLASS DOOR
F.F.L.
2200
1600
GLASS DOOR
GD
320 40
FRAMELESS
LOCATION:
F.F.L.
2100
D1
F.F.L.
GD
400
GLASS DOOR
GD
700
FRAMELESS
LOCATION:
GD
2100
1700
F.F.L.
GD
2100
F.F.L.
GD
2100
GD
2100
GD
2100
2100
GD
40
1000
40
712
LOCATION:
LOCATION:
W1
W2
7857X735
NO. OF SET:
ROOF DECK
1985
NO. OF SET:
3
SCHEDULE OF DOORS AND WINDOWS
NOTES:
1. THE SUMMARY OF DOORS, FINISH HARDWARES AND ACCESSORIES ARE
INDICATIVE DONE TO SERVE AS A GUIDE. VERIFY DRAWINGS FOR EXACT
AREAS OF APPLICATION. SHOULD THERE BE ANY DISCREPANCY WITH
THE DRAWINGS, VERIFY WITH THE ARCHITECT BEFORE PROCEEDING.
2. PROVIDE MASTER KEYING AND COORDINATE WITH THE BUILDING OPERATOR
LOCKSET FUNCTIONS FOR COMMON AREAS & BACK-OF-HOUSE AREAS
INCLUDING PIPE CHASES, AUXILLIARY ROOM & ELECTRICAL ROOM (VERIFY
WITH THE OWNER).
1:50M
3. ALL HARWARES WITH YALE, SCHLAGE, STANLEY BRAND SHOULD BE U.S. MADE.
ALL HARDWARES & ACCESSORIES W/ HAFELE BRAND SHOULD BE GERMAN
MADE. SAME HARDWARE BRAND FROM OTHER COUNTRIES WILL NOT BE
ACCEPTED.
4. DOOR FACE FINISH ALONG THE RESIDENTIAL UNITS HALLWAY OR PUBLIC
HALLWAY TO BE FINISHED BY INTERIOR DESIGNER (REFER TO I.D. DRAWINGS
& SPECIFICATIONS).
5. FOR FIRE EXIT DOOR EXIT DEVICE AT GROUND LEVEL, LEVER HANDLE LOCATED
AT PULL SIDE OF DOOR SHALL BE STOREROOM LOCK FUNCTION, SATIN
STAINLESS STEEL FINISH. GRADE 1 WITH ONE YEAR MINIMUM WARRANTY.
A:A7-02