INSTRUMENTACION INDUSTRIAL:

MEDIDORES MASICOS
Ing. CARLOS E. COTRINO B. M. Sc.

Fuerza de Coriolis
Cor i o lis (k r-lis).
Una fuerza ficticia usada para describir
matemticamente un movimiento, como el de un
avin o una formacin de nubes, relativo a un
marco de referencia no inercial con movimiento
rotatorio uniforme, como la tierra. [ Gaspard G.
de Coriolis (1792-1843), Matemtico francs.]

C.COTRINO-NOV-2011

Page
1

Fuerza de Coriolis3
CORIOLIS FORCE = 2 x BALL MASS x
BALL VELOCITY x PLATFORM
ANGULAR VELOCITY

C.COTRINO-NOV-2011

Fuerza de Coriolis3
Fuerza Coriolis = 2 . m . V x

C.COTRINO-NOV-2011

Page
2

Principio de operacin1
Teora de operacin:
Midpoint
Measuring Tube with flow

Measuring Tube without flow

Fc

Fc

Flow
w

Direction of Oscillation

Sensors A & B

C.COTRINO-NOV-2011

Principio de operacin1

Fc
Coriolis Force

= 2 m [
Mass

Angular Speed
of Rotation

C.COTRINO-NOV-2011

Velocity

Page
3

Principio de operacin1
Sensor A

Mass Flow = 0
Sensor B

Sensor A

Sensor B

Sensor A

Mass Flow > 0


Sensor B

C.COTRINO-NOV-2011

Principio de operacin4

C.COTRINO-NOV-2011

Un tubo lleva un
magneto y el otro lleva
una bobina colectora o
pickup.
Las ondas seno
generadas representan
el movimiento de un
tubo respecto al otro.

Page
4

Principio de operacin4

Los tubos oscilan con una


diferencia de fase de 180.
Los pick ups interno y
externo generan ondas
seno continuamente.
Cuando el tubo esta vaco
no se genera diferencia de
fase

C.COTRINO-NOV-2011

Principio de operacin4

C.COTRINO-NOV-2011

Cuando pasa fluido a travs


de los tubos se generan
fuerzas de Coriolis.
Cuando el tubo tiende a
subir durante el semiciclo
correspondiente el fluido
tiende a impulsarlo hacia
abajo

10

Page
5

Principio de operacin4

Esta diferencia de
momentum angular
produce una torsin del
tubo
La torsin del tubo hace
que las seales generadas
por los pickups estn
fuera de fase.
La diferencia de fase se
mide por un T

C.COTRINO-NOV-2011

11

Principio de operacin4

K es el factor de
Calibracin de cada tubo.
Depende del material y la
temperatura.
Q = K*T
Coeficiente de temperatura
: % de cambio de la
elasticidad por 100 C

C.COTRINO-NOV-2011

12

Page
6

Principio de operacin4

Cuando el volumen de
fluido en el tubo permanece
constante, los cambios en la
masa son debidos a los
cambios de densidad.
La frecuencia de oscilacin
del tubo depende de la
masa y de la densidad

13

C.COTRINO-NOV-2011

Principio de operacin4

C.COTRINO-NOV-2011

Cuando la masa del


fluido aumenta, la
frecuencia de oscilacin
decrece.
Cuando la masa del
fluido disminuye, la
frecuencia de oscilacin
aumenta

14

Page
7

Principio de operacin4
La seal de frecuencia se
toma del pickup izquierdo
(LPO).
Se mide el periodo de la
oscilacin en
microsegundos
La densidad es
directamente proporcional
al periodo

C.COTRINO-NOV-2011

15

Caractersticas
Medicin directa de gran exactitud:

Flujo msico
Densidad
Temperatura
Medicin indirecta de Flujo volumtrico

En la medicin no afectan cambios de: Presin,


Temperatura, Densidad, Viscosidad, Rgimen de flujo,
Conductividad, Velocidad.
Tipo de montaje (no es necesario definir tramos de
medicin).

C.COTRINO-NOV-2011

16

Page
8

Aplicaciones

Slurries
Viscosidad variable
Lquidos sanitarios
Lquidos abrasivos
Lquidos de densidad variable
Lquidos sensibles al cizallamiento
Lquidos adheribles
Gases

17

C.COTRINO-NOV-2011

Masa vs. Volumen

Ejemplo
200 L

195 L

GASOLINA
A 15 DEG C

GASOLINA
A -6.5 DEG C

146 Kilogramos

146 Kilogramos

C.COTRINO-NOV-2011

18

Page
9

Flujo bifsico3
Flujo bifsico anular: El liquido fluye por las paredes y el
gas circula por el centro de la tubera a gran velocidad.

19

C.COTRINO-NOV-2011

Flujo bifsico3
Flujo bifsico con burbujas:

Alta viscosidad

Baja viscosidad
C.COTRINO-NOV-2011

20

Page
10

Flujo bifsico3
Flujo bifsico con slug flow:

C.COTRINO-NOV-2011

21

Tipos de tubo3

C.COTRINO-NOV-2011

22

Page
11

Flujo dividido4

C.COTRINO-NOV-2011

23

Tubos rectos5

C.COTRINO-NOV-2011

24

Page
12

Tubo recto4

C.COTRINO-NOV-2011

25

Especificaciones1

C.COTRINO-NOV-2011

26

Page
13

Especificaciones1

C.COTRINO-NOV-2011

27

Especificaciones1

C.COTRINO-NOV-2011

28

Page
14

Especificaciones1

C.COTRINO-NOV-2011

29

Especificaciones1

C.COTRINO-NOV-2011

30

Page
15

Especificaciones1

C.COTRINO-NOV-2011

31

Prdida de presin 9

C.COTRINO-NOV-2011

32

Page
16

Prdida de presin 9

C.COTRINO-NOV-2011

33

Prdida de presin 9

1: Standard; 2: High pressure

C.COTRINO-NOV-2011

34

Page
17

Vibracin7,10
If the external vibration is close to the
working frequency of the Coriolis mass
flowmeter, measurement errors will
occur.
Pulsation is not only critical at the
working drive frequency fE of the mass
flowmeter but also at frequencies f = fc
fe , where fc is the Coriolis frequency

C.COTRINO-NOV-2011

35

Vibracin7,10

Coriolis mass flowmeters with high


working frequencies are much less sensitive
to pulsation and external vibrations than
others.
For severely vibrating applications, where
the low working frequency of the Coriolis
mass flowmeters might become critical, the
influence of the external vibration can be
considerably reduced by using flexible piping
and vibration isolating pipe supports.
C.COTRINO-NOV-2011

36

Page
18

Instalacin9

Entrained air or gas


bubbles in the
measuring tube can
result in an increase
in measuring errors.
Avoid the following
locations:
Highest point in a run.
Directly upstream
from a free pipe outlet
in a down pipe.

C.COTRINO-NOV-2011

37

Instalacin3,9

Recommended
orientation with upward
direction of flow.
Entrained solids sink
down.
Gases rise away from the
measuring-tube when
fluid is not flowing.
The measuring tubes can
be completely drained
and protected against
solids build-up.

C.COTRINO-NOV-2011

38

Page
19

Instalacin9

Transmitter housing
above or below the
pipe.
This arrangement
means that no gas
and air
accumulations and
solid deposits can
form in the curved
measuring tube
(single-tube system).

C.COTRINO-NOV-2011

39

Instalacin3,9
Do not install the sensor
in such a way that it is
suspended in the pipe, in
other words without
support or attachment.
This is to avoid excessive
strain at the process
connection.
The base plate of the
sensor housing is
designed for mounting on
a tabletop, wall or post.

C.COTRINO-NOV-2011

40

Page
20

Instalacin9

Pipe restrictions or the use


of an orifice with a smaller
cross-section than the
nominal diameter prevent
the sensor running empty
while measurement is in
progress
Installation in a down pipe (e.g.
for batching applications):

1 = Supply tank,
2 = Sensor,
3 = Orifice, pipe restrictions
4 = Valve,
5 = Batching tank

C.COTRINO-NOV-2011

41

Instalacin5

Reduzierung

Reduzierung

Instalacin con reduccin

Instalacin con codos

C.COTRINO-NOV-2011

42

Page
21

Calentamiento por vapor5

Verificar mxima temperatura de calentamiento.


(Tpica: 150C).
Solucin para productos viscosos, con tendencia
a solidificarse
43

C.COTRINO-NOV-2011

Aplicaciones6

C.COTRINO-NOV-2011

Engine
consumption
Measurement
Fuel conditioning
and consumption
measurement

44

Page
22

Aplicaciones8
Dairy plants process
raw milk to separate
the cream (or milk fat)
from the milk to
create skim milk.
Standardization of the
milk, where the cream
and skim milk are reblended to create a
standardized milk
with a desired fat
percentage for the
product being made.

C.COTRINO-NOV-2011

45

Aplicaciones8

C.COTRINO-NOV-2011

46

Page
23

Aplicaciones

Fuente: Ing. Jairo Velasco

C.COTRINO-NOV-2011

47

Ventajas / Limitaciones

Ventajas:
Gran Exactitud
Gran Rangeabilidad
Flujo Bi direccional.
No requiere tramos rectos de tubera
Factor de calibracin universal.
Mltiples medidas
Fluidos viscosos, no newtonianos
Gases
C.COTRINO-NOV-2011

48

Page
24

Ventajas / Limitaciones

Limitaciones:

Costo alto
Costo de instalacin alto
Rango de temperatura limitado
Restriccin en fluidos bifsicos
Peso
Cada de presin
Vibracin

C.COTRINO-NOV-2011

49

Especificaciones
..\Soporte\Especificaciones\E+H coriolis
massflowmeter.pdf
..\Soporte\Especificaciones\ISA_TR20_00
_01_2001_ Coriolis.pdf
..\Soporte\Especificaciones\Micro_Motion
_Tube.pdf
..\Soporte\Especificaciones\Micro_Motion
_Transmitter.pdf

C.COTRINO-NOV-2011

50

Page
25

Referencias
1.

2.

3.
4.
5.
6.

Micro Motion. F-Series Coriolis Flow and Density


Meters Product Data Sheet PS-00603, Rev. E. June
2007.
Micro Motion. Model D and DT Mass Flow and
Density Sensors Product Data Sheet. PS-00388, Rev. B.
March 2005.
Foxboro. I/A Series mass Flowmeters. PS 1-2B4 A.
Micro Motion. Coriolis mass meters tutorial.
Khrone. OPTIMASS 1300 - Product data Sheet.
SIEMENS. Sitrans FC Transmitters. WS 080810.0.
Siemens AG 2008

C.COTRINO-NOV-2011

51

Referencias
7.

Cheesewright R. et. al. The identification of external factors which


influence the calibration of Coriolis massflow meters. Flow
measurement and instrumentation.Vol 11. (2000) pages 1-10

8.

Micro Motion. AN-001203 Coriolis Flow Meters Improve


Accuracy of Standardization Process in Milk Preparation. 2009.

9.

Endress and Hauser. Coriolis Mass Flow Measuring System


Promass 80/83 A .TI 054D/06/en 2010

10.

Martin Anklina, Wolfgang Drahmb,, Alfred Riederb. Coriolis mass


flowmeters: Overview of the current state of the art and latest
research. Flow Measurement and Instrumentation 17 (2006) 317
323.

C.COTRINO-NOV-2011

52

Page
26

Vous aimerez peut-être aussi