Académique Documents
Professionnel Documents
Culture Documents
Manuals of food
quality control
1. The food control laboratory
FAO
FOOD AND
NUTRITION
PAPER
Rev. 1
Food
and
Agriculture
Organization
of
the
United
Nations
Manuals of food
quality control
1. The food control laboratory
FAO
FOODAND
NUTRITION
PAPER
14/1
Rev. 1
by
P.G. Martin
revised by
J. Weatherwax
and
P.G. Martin
Food
and
Agriculture
Organization
of
the
United
Nations
Rome, 1997
Reprinted 1997
M-87
ISBN 92-5-102489-8
FOREWORD
to
establish
a workable
food
control
system,
national
government
1.
2.
3.
4.
5.
and
analysis
staff
within
the
agency
or
No. 14/2
No. 14/3
No. 14/4
Microbiological Analysis
No. 14/5
Food
No. 14/6
No. 14/7
No. 14/8
Food Analysis:
Identity
(replaced
Inspection
In a d d i t i o n , FAO, WHO and UNEP jointly have published many guidelines and other
documents designed to further assist developing countries in forming adequate
food control systems. These publications include:
Methods of Sampling and Analysis of Contaminants in Food A Report of the Second Joint FAO/WHO Expert Consultation,
Rome - 1978
Guidelines for Establishing or Strengthening National Food
C o n t a m i n a t i o n M o n i t o r i n g Programmes - FAO Food Control
Series No. 5 - 1979
iii
Pesticide
Residues,
TABLE OF CONTENTS
FOREWORD
1.
2.
LABORATORY
2.1
2.2
2.3
2.4
2.5
2.6
2.7
3.
2
3
3
4
5
5
6
General Considerations
Basic Structure of the Building
Safety Features
Ventilation and Air Conditioning
Space Utilization
Equipment and Instruments
Utilities
Design References
7
7
10
12
13
15
16
18
LABORATORY ADMINISTRATION
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
5.
ORGANIZATION
LABORATORY DESIGN
3.1
3.2
3.3
3.4
3.5
3.6
3.7
3.8
4.
Sample Collection
Sample Receipt and Assignment
Sample Storage and Disposal
Budget
Purchasing
Supplies Management
Equipment Maintenance
Housekeeping
Training
LABORATORY
5.1
5.2
5.3
5.4
5.5
5.6
5.7
5.8
20
21
22
23
23
26
26
28
28
OPERATIONS
Workp lans
Priorities for Analysis
Analysis Assignment
Analysis Control
Analysis Reporting
Analysis Review
Method Validation
Confirming Analysis
. . . . .
29
31
31
32
32
33
34
34
6.
LABORATORY
6.1
6.2
6.3
6.4
6.5
6.6
6.7
6.8
7.
SAFETY
35
35
36
37
38
40
42
43
(QA)
Introduction
Establishing a QA Programme
QA of Reference Standards
QA of Instruments
QA of Analytical Reports
Check Sample Examination
Other QA Activities
Text References
46
46
49
. . 55
58
61
66
66
vi
1.
2.
2.1
Establishing
the
LABORATORY
ORGANIZATION
Laboratory
2.2
Organizational
The staffing
Structure
structure
of a typical
food
Head of
Analytical
Staff
control
laboratory
is as
follows:
Laboratory
Support
Staff
Administrative
Staff
2.3
Head
of the
It is
needs
Laboratory
The H e a d of the l a b o r a t o r y s h o u l d be a g r a d u a t e c h e m i s t or m i c r o b i o l o g i s t
trained in food analysis.
A postgraduate d i p l o m a particularly relevant to this
w o r k is h i g h l y d e s i r a b l e .
A l t h o u g h the d u t i e s of the h e a d of the l a b o r a t o r y
are m a n y , s o m e m a y be d e l e g a t e d and o t h e r s u n d e r t a k e n b y o t h e r p a r t s of the
food control administration.
It is therefore not appropriate to do more than
d r a w a t t e n t i o n to c e r t a i n a s p e c t s .
The o b j e c t i v e of the l a b o r a t o r y is to
analyze a large number of samples correctly, quickly and cheaply.
This means
t h a t a t t e n t i o n m u s t be paid to c a r e f u l s p e n d i n g of the b u d g e t , p r o m o t i o n of
good staff relations and maintenance of the highest possible level of technical
efficiency and expertise.
The laboratory Head may have to give evidence in court or write documents used
in c o u r t , in w h i c h c a s e he m u s t h a v e a t h o r o u g h u n d e r s t a n d i n g of food and
related law and court procedure.
There will also be involvement in c o m m i t t e e
work and relations with other organizations.
The laboratory Head is usually
the spokesman for the laboratory in many instances.
The Head must prepare work
p l a n s w i t h the i n s p e c t o r a t e and o v e r a l l food c o n t r o l a u t h o r i t i e s .
Sampling
p l a n s a g r e e d w i t h the i n s p e c t o r a t e s h o u l d aim at a r e a s of c o n c e r n and m a j o r
abuses.
In the e a r l i e r y e a r s or w h i l e the l a b o r a t o r y r e m a i n s s m a l l , the Head of the
laboratory is the one who makes most of the m a n a g e m e n t decisions.
The Head is
also the person who interacts with higher m a n a g e m e n t .
This is a most important
aspect as the laboratory m u s t be fully integrated into the executive s tructure
in a m e a n i n g f u l w a y .
It w o u l d be f u t i l e for a l a b o r a t o r y to w o r k in an
administrative v a c u u m , producing r e s u l t s s h o w i n g , for e x a m p l e , that s a m p l e s
2.4
Supervisors
S u p e r v i s o r s s h o u l d a l s o be g r a d u a t e c h e m i s t s or m i c r o b i o l o g i s t s w i t h
considerable food analysis experience.
The supervisor is the on-site manager
of the laboratory.
Having supervisors assigned to specific units or areas of
work permits the Head to more effectively plan (and execute) the total workload
of the laboratory.
S u p e r v i s o r s can be e x p e c t e d to do a n a l y t i c a l w o r k in a d d i t i o n to their
supervisory duties.
H o w e v e r , if their g r o u p e x c e e d s five p r o f e s s i o n a l
a n a l y s t s , it is best not to r e q u i r e a d d i t i o n a l a n a l y t i c a l w o r k e x c e p t for
occasional problem solving and trouble-shooting.
A reasonable m a x i m u m number
of a n a l y s t s for one p e r s o n to s u p e r v i s e is 10 to 12. T h i s can be m o r e if n o n professional support staff is added.
A supervisor's duties can include many or all of the
1.
Assisting the Head in overall
the work of the group supervised.
2.
posed
Receiving
and assigning
samples
laboratory
5.
Ensuring
do the work.
the
that
reports
the
of
6.
Ensuring that proper
followed by the group.
work
the necessary
laboratory
planning
in s o l v i n g
completed
group has
work
3.
A n s w e r i n g q u e s t i o n s and a s s i s t i n g
by individual analysts.
4.
Reviewing
recommendations.
following:
and
and
the group.
analytical
making
supplies
planning
and
problems
appropriate
equipment
practices
to
are
7.
R e c o m m e n d i n g to the Head n e w i n s t r u m e n t s or e q u i p m e n t n e e d e d , and
training needs of individual analysts.
8.
Taking appropriate disciplinary
laboratory rules or regulations.
9.
Acting
action
laboratory
when
needed
to
enforce
Supervisors should train one or more analysts in their group to serve as backups, to supervise the group in the supervisor's absence.
The back-ups should
be given some formal classroom training in supervision in addition to on-thejob experience.
A good supervisor is indispensable to the smooth operation of a laboratory.
In
s e l e c t i n g a s u p e r v i s o r , the Head m u s t k e e p in m i n d that the p r i m a r y job of a
s u p e r v i s o r is to m a n a g e , so that s k i l l s in w o r k i n g w i t h p e o p l e are m o r e
i m p o r t a n t than s c i e n t i f i c e x p e r t i s e .
T h e r e f o r e , a top a d m i n i s t r a t o r w i t h
2.5
Team
Leaders
A n o t h e r i m p o r t a n t , and o f t e n o v e r l o o k e d , p o s i t i o n is T e a m L e a d e r .
A team
leader is a senior analyst w h o h a s b e e n assigned a s m a l l g r o u p , u s u a l l y no m o r e
t h a n 4 , to do a s p e c i f i c
t a s k or t y p e of a n a l y s i s .
T h e l e a d e r h a s no
s u p e r v i s o r y functions as such, but is the c o o r d i n a t o r of the g r o u p ' s a c t i v i t i e s
and is the contact point for the supervisor.
T e a m l e a d e r s are m o s t u s e f u l w h e n a l a r g e n u m b e r of a r e p e t i t i v e type of
a n a l y s i s is to be done in a specified period of time.
This could be a specific
a n a l y t i c a l s u r v e y or a n e m e r g e n c y p u b l i c h e a l t h p r o b l e m r e q u i r i n g s c r e e n i n g
analyses.
T h e l e a d e r u s u a l l y w o r k s a l o n g w i t h the g r o u p in a d d i t i o n to the
coordinative function.
S u c h e x p e r i e n c e is o f t e n u s e f u l to d e t e r m i n e if t h e
assigned leader has potential as a future supervisor.
2.6
Analytical
Staff
The basic job of the analytical staff is to analyze the s a m p l e s received and to
issue a report.
They m a y also be required to a p p e a r in court as fact or expert
w i t n e s s e s to give e v i d e n c e in r e l a t i o n to a report.
They m a y also be called on
to o f f e r a d v i c e to i n d u s t r y and t r a d e , to a s s i s t in i m p r o v e m e n t o f f o o d
q u a l i t y , or advise on c o n f o r m i t y w i t h s t a n d a r d s or other legal r e q u i r e m e n t s .
T h i s c a n i n v o l v e t h e l a b o r a t o r y s t a f f in f a c t o r y v i s i t s a n d e v e n r e q u e s t s to
c a r r y out e x p e r i m e n t a l w o r k .
W h e t h e r or n o t the l a b o r a t o r y u n d e r t a k e s s u c h
w o r k w i l l be a m a t t e r of o r g a n i z a t i o n a l policy.
The d e c i s i o n w i l l depend on a
n u m b e r of f a c t o r s , i n c l u d i n g the a v a i l a b i l i t y of a l t e r n a t i v e facilities, the
n a t u r e of i n d i v i d u a l o w n e r s h i p ,
etc.
T h e i n t e g r i t y of the a n a l y s t
is
p a r a m o u n t , and s u p e r i o r s m u s t be i n f o r m e d of a n y c o n f l i c t of i n t e r e s t t h a t
a r i s e s . A s in t h e c a s e o f f o o d i n s p e c t o r s , it is p r o p e r f o r t h e a n a l y s t s to
have no vested interest in regulated industries.
This r e q u i r e m e n t is m a n d a t o r y
in m a n y countries.
A n a l y t i c a l staff can be d r a w n from three levels, u n i v e r s i t y g r a d u a t e s , trained
t e c h n i c i a n s f r o m t e c h n i c a n t r a i n i n g c o l l e g e s and u n q u a l i f i e d s t a f f w h o h a v e
received o n - t h e - j o b training.
The g r a d u a t e s can be c h e m i s t s , m i c r o b i o l o g i s t s ,
food scientists or fi od t e c h n o l o g i s t s .
U n i v e r s i t y d e g r e e s are only a starting
q u a l i f i c a t i o n and the-p. w i l l still be a r e q u i r e m e n t for specialized training
a n d e x p e r i e n c e in f o o d . n a l y s i s .
S t a f f s h o u l d be e n c o u r a g e d to c o n t i n u e to
w o r k for s u i t a b l e p o s t g r a d u a t e q u a l i f i c a t i o n s to e n a b l e t h e m to c o m p e t e for
h i g h e r posts in the laboratory.
S p e c i a l l y trained l a b o r a t o r y t e c h n i c i a n s w h o
h a v e f o l l o w e d a t w o to t h r e e y e a r p r a c t i c a l t r a i n i n g c o u r s e in l a b o r a t o r y
a n a l y s i s a f t e r c o m p l e t i n g s e c o n d a r y s c h o o l c a n be p a r t i c u l a r l y u s e f u l in
carrying out a n u m b e r of routine or even h i g h l y c o m p l e x food analyses.
As in
the c a s e w i t h u n i v e r s i t y g r a d u a t e s , s p e c i a l i z e d o n - t h e - j o b t r a i n i n g w i l l b e
needed for particular types of food analysis.
2.7
Support
Staff
Glassware
washing.
2.
Cleaning
and
3.
Disposal
of s a m p l e
4.
Pest
control.
5.
Heavy
lifting
housekeeping
and
maintenance.
reserves
( w h e n no
longer
required).
moving.
the
not
It is m o s t i m p o r t a n t t h a t s u f f i c i e n t p e r s o n s a r e h i r e d as s u p p o r t .
The w o r k
t h e y do m u s t be d o n e by s o m e o n e and t h i s is u s u a l l y an a n a l y s t or t e c h n i c i a n
w h e n there is i n s u f f i c i e n t support staff.
There is no fixed m o d u l e for n u m b e r s
of s u p p o r t w o r k e r s , b u t 1 5 - 2 0 % of the n u m b e r of a n a l y t i c a l s t a f f is o f t e n
sufficient.
3.
3.1
LABORATORY DESIGN
General Considerations
W h e n a new laboratory is being built, two people hold the key positions in
producing the right building at the right cost - the architect who designs it
and guides its construction, and the analyst (preferably the laboratory Head)
w h o explains the technical needs, and w o r k s in close p a r t n e r s h i p w i t h the
architect through every stage so that the end result is properly suited to the
requirements of the users.
It is not often that the analyst has the chance to
take part in the planning of a complete new laboratory, more usually he has to
make do with old or inadequate buildings. However, these are often more easily
extended, changed or adapted as the nature of the w o r k changes, than a n e w e r
building, so may in some ways be more advantageous.
Indeed, an important point
in designing a new laboratory is that provision should be made for future
expansion, however unlikely that may seem at the time. The design should also
be left as flexible as possible so that changes of emphasis in the work can be
a c c o m m o d a t e d . The laboratory should be located a w a y from urban centres and
industrial areas in order to minimize problems of contamination.
The information in this chapter was taken in part from Industrial Research and
D e v e l o p m e n t N e w s , VII No. 3, UN, N.Y., 1975.
The principles given apply to
food control l a b o r a t o r i e s in general, w h e t h e r n e w c o n s t r u c t i o n or space
converted to laboratory use.
3.2
An example of the smallest laboratory that would be adequate for a food control
programme is shown in Figure 3.1. This design was originally intended to serve
120,000 people although in general this may be regarded as too small a
p o p u l a t i o n to justify a separate laboratory.
It is intended to be part of a
larger b u i l d i n g , but the disposition of r o o m s can be changed to suit local
c i r c u m s t a n c e s . Space for essential services such as solvent storage and the
usual administrative support must also be provided.
Sample preparation should
be carried out as far as possible from laboratories working on trace analysis
and microbiology or using sensitive instruments.
It must be stressed that the
figure s h o w n is only an e x a m p l e .
New l a b o r a t o r i e s m u s t be c u s t o m - b u i l t to
cater for the needs of the situation under consideration.
It is best to allow l a b o r a t o r i e s to r e m a i n o p e n - p l a n as far as p o s s i b l e ,
including the areas used as offices. Exceptions are areas where the activities
carried out cause c o n t a m i n a t i o n or are sensitive to it, such as s a m p l e
preparation, weighing, microbiology, trace analysis and use of instruments such
as gas-liquid chromatographs and spectrophotometers.
Lack of v i b r a t i o n is important and therefore concrete is a better structural
m a t e r i a l in m u l t i - s t o r e y
buildings.
S t e e l - f r a m e b u i l d i n g s m a y cause
d i f f i c u l t y with some i n s t r u m e n t s .
A two storey laboratory adequate for a
modest food control programme is shown in Figures 3.2 and 3.3. It consists of
a ground floor m a i n l y composed of offices and services and a first floor for
analytical work.
In addition there should be a flammable solvent storage area
separate from the building. W o r k s h o p and g l a s s b l o w i n g facilities are often
advantageous and if not otherwise available should be included.
1 ni i
>
Food
additives
and
toxicants
Food
standards
and nutrition
Corridor
Overall
length
21 m
Microbiology
Media
prparai ion
Office
Balance
room
Sample
prparai ion
1vK
Entrance
6.2 m
6.2 m
Figure 3.1
A Minimum Sized Food Control Laboratory
Figure 3.2
Ground Floor Plan
(mainly office and administrative
space)
Figure 3.3
First Floor Plan
(laboratory space)
3.3
Safety
Features
The building
including :
1.
The
and
laboratory
fire
design
should
a r e a s of c o r r i d o r s
include
a number
s h o u l d be f o r m e d
of
safety
of c o n c r e t e
features
blocks.
2.
Services should include a shower sprinkler system near each d o o r w a y
so t h a t a w o r k e r c a n t a k e an i m m e d i a t e s h o w e r , c l o t h e s and a l l , in the c a s e of
a c c i d e n t a l g e n e r a l c o n t a c t w i t h c o r r o s i v e or p o i s o n o u s l i q u i d s or f i r e .
10
3.
wash
There
stations
should
be
(obtainable
built-in
from
most
eye
wash
chemical
fountains,
supply
or
at
least
portable
eye
firms).
4.
The t r a f f i c
flow,
the e g r e s s p a t t e r n and the p r o p o r t i o n s of
the
l a b o r a t o r y are a l l s a f e t y c o n s i d e r a t i o n s .
I t m u s t a l w a y s be p o s s i b l e to l e a v e
the l a b o r a t o r y s a f e l y i r r e s p e c t i v e of the i n i t i a l s i t e of a f i r e .
Serious
t h o u g h t m u s t be g i v e n to t h e n u m b e r and l o c a t i o n o f f i r e e x t i n g u i s h e r s
and
s t a n d p i p e s y s t e m s , and to the a v a i l a b i l i t y of s p r i n k l e r
systems.
5.
L a b o r a t o r i e s s h o u l d b e w e l l - l i t so t h a t t h e o p e r a t o r d o e s n o t h a v e
to p e e r too c l o s e l y o v e r p o t e n t i a l l y h a z a r d o u s m a t e r i a l i n o r d e r to see w h a t he
is doing.
T h e r e s h o u l d be a m p l e w o r k i n g s p a c e and b e n c h t o p s and o t h e r s u r f a c e s
s h o u l d be k e p t c l e a r of a l l m a t e r i a l e x c e p t t h a t i n c u r r e n t u s e .
6.
Benches are best w i t h o u t s h e l v e s , only s e r v i c e s , these being operated
from the f r o n t so t h a t the o p e r a t o r d o e s not h a v e to s t r e t c h a c r o s s the b e n c h .
I t i s s t i l l common to s e e r e a g e n t s on s h e l v i n g at t h e b a c k o f b e n c h e s ( o r a b o v e
the c e n t r e of d o u b l e - w i d t h b e n c h e s ) b u t i t i s p r o b a b l y s a f e r i f such r e a g e n t s
c a n be k e p t on s i d e - s h e l v e s or i n t r a y s w h i c h a r e b r o u g h t to t h e b e n c h as
required .
7.
F l o o r i n g n e e d s to b e o f a n o n - s l i p m a t e r i a l , r e s i s t a n t to a c i d s a n d
s o l v e n t s , b u t n o t so h a r d a s to b e t i r i n g to s t a n d on f o r a f e w h o u r s at a
time.
No m a t e r i a l i s e n t i r e l y s a t i s f a c t o r y .
W e l l - l a i d l i n o l e u m and a f i l l e d
e p o x y r e s i n on top of c o n c r e t e a r e a m o n g t h e b e s t a v a i l a b l e .
It is a d v i s a b l e
n o t to p o l i s h l a b o r a t o r y
floors.
8.
P o l l u t a n t s g e n e r a t e d w i t h i n t h e l a b o r a t o r y m u s t be r e m o v e d s a f e l y ,
q u i c k l y and e f f i c i e n t l y .
I n p a r t i c u l a r , t o x i c or n o x i o u s g a s e s m u s t be r e m o v e d
e x p e d i t i o u s l y t h r o u g h a d u c t s y s t e m t h a t d o e s n o t e x h a u s t n e a r the b u i l d i n g a i r
conditioning
intake.
9.
The b u i l d i n g must be p l a n n e d f o r s e c u r i t y .
R e s t r i c t i o n of a c c e s s i s
of c o n s i d e r a b l e i m p o r t a n c e b e c a u s e of the e x t r e m e l y v a l u a b l e and
sensitive
e q u i p m e n t u s e d i n t h e l a b o r a t o r y w o r k a s w e l l as t o p r o t e c t t h e i n t e g r i t y o f
official
samples.
10.
I t i s v e r y a d v i s a b l e to h a v e an e f f i c i e n t f i r e a n d s m o k e d e t e c t i o n
system w i t h appropriate alarms.
Common f i r e d e t e c t i o n e q u i p m e n t is
usually
e i t h e r r a t e - o f - t e m p e r a t u r e - r i s e or f i x e d - t e m p e r a t u r e d e t e c t o r u s i n g a s u b s t a n c e
of known m e l t i n g p o i n t .
T h e r e a r e a d v a n t a g e s ( a n d d i s a d v a n t a g e s ) to e a c h t y p e
of d e t e c t o r and the l a b o r a t o r y Head s h o u l d s e l e c t the one he f e e l s b e s t f i t s
his laboratory.
D e s i g n i n g a l a b o r a t o r y to a f f o r d p r o t e c t i o n a g a i n s t e v e r y k i n d o f h a z a r d w o u l d
be a l m o s t i m p o s s i b l e .
The a i m s h o u l d be to d e t e r m i n e t h e l e v e l o f s a f e t y
for
t h e most g e n e r a l a p p l i c a t i o n s and to p r o v i d e s u p p l e m e n t a r y s y s t e m s in a r e a s o f
higher h a z a r d .
A s a f e s o l v e n t s t o r a g e a r e a i s i d e a l l y s e p a r a t e from t h e l a b o r a t o r y b u i l d i n g i n
a stand-alone structure.
I t c a n be a s m a l l b u i l d i n g of one room and
some
p o s s i b l e d e s i g n f e a t u r e s a r e : ( r e a s o n s are g i v e n in p a r e n t h e s i s )
1.
materials
Construction
s u r r o u n d the
of
cement
solvents.)
blocks
or
bricks.
(Only
non-flammable
2.
For a s t a n d - a l o n e b u i l d i n g , d o u b l e w a l l s w i t h i n s u l a t i o n
between.
The e x t e r i o r
w a l l c a n be m a t e r i a l
other
than block
or b r i c k .
(Provides
i n s u l a t i o n from the sun and m a k e s a i r c o n d i t i o n i n g more e f f e c t i v e . )
3.
An e p o x y f i l m to c o v e r t h e e n t i r e
walls.
( A n y s o l v e n t s p i l l a g e w i l l p o o l and
t h e f l o o r s or w a l l s . )
11
floor plus
evaporate,
10 cm up t h e b a s e of t h e
r a t h e r than soak through
4.
A c o p p e r pipe (about 25 m m ) inside the r o o m , w h i c h goes t h r o u g h the
floor and is e m b e d d e d a b o u t 2 m in earth.
(A g r o u n d pipe to bleed off any
static e l e c t r i c i t y c h a r g e s - w h i c h o f t e n build up w h e n s o l v e n t s are poured).
All metal objects in the room are to be attached to the pipe using heavy guage
single strand copper wire.
Also, attach a short wire with an alligator clip.
(This g r o u n d s all m e t a l .
The clip is used to g r o u n d any m e t a l cans used for
s o l v e n t transfer.)
5.
grounding
Storage
pipe.
shelves of metal
and connected
by wire
the
6.
Air c o n d i t i o n i n g is e x t e r n a l , w i t h the e n t r a n c e duct at the top of
one c o r n e r of the r o o m and the exit d u c t at the b a s e of the o p p o s i t e c o r n e r .
( T h e r o o m m u s t be c o o l e d as m a n y s o l v e n t s w i l l b o i l at h o t o u t s i d e
temperatures. The air entrance on top and exit on the bottom diagonally across
the r o o m , w i l l cool the room and w i l l also serve to s w e e p and r e m o v e any
solvent fumes on the floor - solvent fumes are generally heavier than air and
will pool on the floor.)
7.
The door is of m e t a l and f i r e - r a t e d for at least one h o u r , w i t h a
positive closure.
It must seal well when closed. The door sill is at least 10
cm high.
(Fire doors are metal sheathed around cement.
The closure, the seal
and the h i g h sill all act to p r e v e n t e s c a p e of s o l v e n t , e i t h e r floor s p i l l a g e
or fumes.)
8.
An air c o n d i t i o n e r exit duct w i t h a fire b a f f l e (to p r e v e n t flash
b a c k ) and d u c t e d to exit in the o u t s i d e air at b u i l d i n g r o o f h e i g h t .
(Fumes
h a v e a b e t t e r c h a n c e of being carried a w a y by b r e e z e s and s o m e o n e s m o k i n g
nearby will not present a fire risk.)
9.
An extinguisher system,
and not water sprinklers.
3.4
which
should
Conditioning
An ordinary laboratory may have amounts of lead in the air passing through it
in a day which can be measured in milligrams.
Natural ventilation, which may
provide large quantities of air without cooling, is not generally suitable for
laboratories.
T h i s is e s p e c i a l l y true in u r b a n a r e a s w h e r e m o t o r t r a f f i c is
high.
This means that air conditioning is essential for the modern laboratory.
A i r c o n d i t i o n i n g not only p r e v e n t s s o m e f o r m s of c o n t a m i n a t i o n , it also
p r o v i d e s a s t a b l e t e m p e r a t u r e e n v i r o n m e n t for s e n s i t i v e and s o p h i s t i c a t e d
analytical instruments. Most v o l u m e t r i c g l a s s w a r e is c a l i b r a t e d at 20C and
must be recalibrated if used at significantly different temperatures.
This is
s t i l l a n o t h e r a r g u m e n t for air c o n d i t i o n i n g .
T h e i m p o r t a n c e of a i r
conditioning to overall laboratory accuracy cannot be overstressed.
The exhaust fans in fume hoods result in a negative pressure in the laboratory
and in an urban or industrial area this aggravates contamination of the whole
l a b o r a t o r y area.
A p o s i t i v e p r e s s u r e s y s t e m is c o s t l y as it h a s to be
s u f f i c i e n t l y p o w e r f u l to p r o v i d e a c l e a n filtered air s u p p l y w h i c h p a s s e s
t h r o u g h f u m e hood e x h a u s t fans as w e l l as o t h e r o u t l e t s .
V e n t i l a t i o n by
p o s i t i v e p r e s s u r e a s s i s t s the e x h a u s t fans in f u m e h o o d s and is to be
preferred.
Each f u m e hood should h a v e a s e p a r a t e fan, as there is d a n g e r of
cross c o n t a m i n a t i o n from a c o m m o n d u c t i n g s y s t e m .
Such a s y s t e m can be
essential if the vicinity of the laboratory is prone to contamination and it is
necessary to carry out low-level trace analysis.
Toxic fumes must be confined
as far as possible to fume hoods.
These should be away from cross-currents of
air and pedestrian traffic.
The recommended m i n i m u m air-flow through the open
face of a f u m e hood is 0.5 m / s e c .
V e n t i l a t i o n s h o u l d be such as to give at
least 5 air changes per hour.
12
3.5
Space
Utilization
L a b o r a t o r y s p a c e m u s t be a r r a n g e d for m a x i m u m u t i l i z a t i o n as w e l l as p r o p e r
w o r k flow.
It is usual to a l l o w about 10 square m e t e r s of laboratory space and
3 m e t e r s of b e n c h s u r f a c e p e r a n a l y s t .
An e x a m p l e of a l a b o r a t o r y for 8
a n a l y s t s is in Figure 3.4.
Sx
FC
Fr
DS
Kj
Figure
"
=
=
=
=
Soxhlet bench
fume cupboard
freezer
sink unit
Kjeldahl apparatus
3.4
N o t e that e a c h a n a l y s t h a s a l a t e r a l b e n c h a r e a to w o r k at.
T h i s f o r m a t is
termed 'peninsular' and is quite e f f i c i e n t .
An a l t e r n a t e f o r m a t uses 'islands'
w h i c h have access on all sides.
An e x a m p l e is Figure 3.5.
13
0.7b m
1.50 m
0.75 m
1.50 m
0.75 m
1.50 m
0.75 m
Consider as island
benches accessible
from every side, or
consider as the floor
space remaining, the
area B being occupied
by benches
Figure
3m
3.5
T h e o p t i m u m w i d t h f o r a s i n g l e b e n c h ( a b o u t 75 cm) i s r o u g h l y t h e s a m e as t h e
width
of
the
space
required
by a s t a n d i n g
individual.
It
is
therefore
convenient,
to c o n s i d e r t h e p r o s and c o n s o f i s l a n d b e n c h e s and
peninsular
b e n c h e s w i t h the a s s i s t a n c e of F i g u r e 3 . 5 .
I t c a n r e a d i l y be s e e n t h a t the
m a x i m u m b e n c h a r e a i s o b t a i n e d w i t h p e n i n s u l a r b e n c h e s (B a r e a s ) , h o w e v e r ,
the
w o r k i n g s u r f a c e is more a c c e s s i b l e on i s l a n d b e n c h e s (A a r e a s ) .
The
services
a r e m o r e a c c e s s i b l e f o r r e p a i r on i s l a n d b e n c h e s , b u t t h e r e i s l e s s
space
available
for s h e l v i n g
close
to t h e b e n c h e s .
In the c a s e of
peninsular
b e n c h e s , t h e a n a l y s t w o r k i n g i n a b a y h a s a c c e s s i n e f f e c t to t h r e e w o r k i n g
s u r f a c e s at o n c e and t h i s i s v e r y c o n v e n i e n t i f t h e r e a r e s e v e r a l
different
a n a l y s e s i n p r o g r e s s at the same t i m e .
H o w e v e r , the s p a c e b e t w e e n p e n i n s u l a r s
s h o u l d a l w a y s be e n o u g h for two p e o p l e to w o r k c o m f o r t a b l y b a c k to b a c k ( a b o u t
1.5 m).
I s l a n d b e n c h e s make the c h o i c e of s i t e for w i n d o w s and d o o r s
less
critical.
P e n i n s u l a r b e n c h e s m a y be p r e f e r r e d i f s p a c e i s a t a p r e m i u m a n d
t h e y may be s l i g h t l y s a f e r ,
as the r o u t e s by w h i c h p e o p l e w a l k a b o u t
the
l a b o r a t o r y t e n d to be m o r e r e s t r i c t e d and p r e d i c t a b l e .
W h i c h e v e r is c h o s e n ,
w h a t i s m o s t i m p o r t a n t i s t h a t t h e s i z e o f t h e r o o m i s c o r r e c t to t a k e a n
i n t e g r a l n u m b e r of b e n c h u n i t s w i t h t h e i r a c c o m p a n y i n g
floor space.
Usually
t h e p r o b l e m c a n be p a r t l y s o l v e d b y a w a l l b e n c h at one end or s i d e of t h e
l a b o r a t o r y but a l l too o f t e n l a b o r a t o r i e s have such a s i z e or shape t h a t f l o o r
s p a c e h a s b e e n w a s t e d , or an e x t r a b e n c h h a s b e e n i n c o n v e n i e n t l y s q u e e z e d
in.
The s t o r a g e a r e a s in the b e n c h e s s h o u l d be m o d u l a r to a l l o w f l e x i b i l i t y .
Many
laboratory
bench
manufacturers
have
units
where
the
storage
areas
are
interchangeable.
Some s a m p l e s of b e n c h a s s e m b l i e s a r e g i v e n in F i g u r e 3 . 6 ,
w i t h w i d t h s in c e n t i m e t e r s .
14
KO
ra
to
1M
(O
m m m
I
f-
"t-
22
to
'
to
110
120
4-
120
10
120
2%0
120
2$o
120
4-
2 tO
120
2so
tO
+4-
4-4-
4"
120
IM
120
4-4rara
1
II
II
4-
220
H
t-
rap nu
+
Il
ira
m m
m rap ra
era
to
M U
4-
SO (O
>0
110
4"
HI
..
Figure
--
--
'
3.6
3.6
Equipment
and
Instruments
15
a n a l y s e s so t h a t , o n c e the m a n y h u n d r e d s of i t e m s r e q u i r e d in a food c o n t r o l
l a b o r a t o r y h a v e b e e n p r o v i d e d , t h e r e c o m e s a p o i n t at w h i c h p r o d u c t i v i t y c a n
rise s h a r p l y and i n v e s t m e n t decrease.
The logistical p r o b l e m s of m a i n t e n a n c e ,
r e p a i r and r e p l a c e m e n t of e q u i p m e n t are also c o n s i d e r a b l e .
Adequate provision
m u s t be m a d e for obtaining spares and r e p l a c e m e n t parts and for their storage.
It is false e c o n o m y if staff are being paid but c a n n o t do an i m p o r t a n t part of
their w o r k due to a lack of r e l a t i v e l y i n e x p e n s i v e e q u i p m e n t .
S o m e of the i n s t r u m e n t s and e q u i p m e n t needed for c h e m i c a l a n a l y s i s by a m o d e r n
food c o n t r o l l a b o r a t o r y are:
(for purposes of this listing, ' i n s t r u m e n t s ' are
m e a s u r i n g d e v i c e s and ' e q u i p m e n t ' are p r o c e s s i n g d e v i c e s .
Apparatus made
p r i m a r i l y of glass are not included).
Instruments
A n a l y t i c a l balance
pH m e t e r
Spectrophotometer, UV-visible, double-beam
S p e c t r o p h o t o m e t e r , atomic a b s o r p t i o n
H i g h P e r f o r m a n c e Liquid C h r o m a t o g r a p h (with UV and d i f f e r e n t i a l r e f r a c t i v e
index d e t e c t o r s )
Gas C h r o m a t o g r a p h (with flame i o n i z a t i o n and e l e c t r o n capture d e t e c t o r s )
Equipment
Blender
Grinder
Pulverizing hammer mill
Air o v e n , forced draft
V a c u u m o v e n , with pump
M u f f l e furnace
Centrifuge
Refrigerator
Freezer
H e a t e r s and hot plates
Steam and w a t e r b a t h s
W a t e r still or d e i o n i z e r
3.7
Utilities
16
suggested.
The laboratory pictured in Figure 3.3 has 160 double 13-amp socket
outlets.
This apparently large n u m b e r adds considerably to the efficiency of
a n a l y t i c a l o p e r a t i o n s and to their s a f e t y .
The s a m e l a b o r a t o r y has 110 gas
p o i n t s , e x c l u d i n g t h o s e to the f u m e h o o d s .
T h e r e m u s t b e s e v e r a l cold w a t e r
taps per b e n c h to a l l o w for r i n s i n g , c o n d e n s e r s , etc., but h o t w a t e r can be
restricted to those sinks w h e r e apparatus is washed.
In a larger laboratory a
distribution system for distilled or deionized water would be advantageous.
():
suggested:
1.2
1.5
1.8
2
2
1
2
3
2
3
4
2
1
2
1
3
1
4
S p e c i a l m e t h o d s , s u c h as t r a c e a n a l y s i s , u s u a l l y r e q u i r e d i s t i l l a t i o n f r o m
g l a s s a p p a r a t u s of w a t e r i n i t i a l l y p a r t i a l l y p u r i f i e d by d i s t i l l a t i o n or
deionization.
The initial purification produces water very low in salts, but
if the o r i g i n a l s u p p l y c o n t a i n s o r g a n i c m a t t e r t h i s m a y n o t be r e m o v e d , and
traces of resin material m a y be present.
A s t e a d y s u p p l y of c o m p r e s s e d air is r e q u i r e d for an a t o m i c
absorption
s p e c t r o p h o t o m e t e r (AAS) and is v e r y u s e f u l to h a v e a v a i l a b l e at the b e n c h . A
c o m p r e s s o r is s u i t a b l e for use w i t h the i n s t r u m e n t but if used for o t h e r
purposes at the same time it m u s t be capable of supplying those needs without
a f f e c t i n g the AAS s u p p l y . A p a r t f r o m the i n a c c u r a c y that w i l l r e s u l t from a
change in the flame characteristics, sudden failure of the air m a y result in a
flashback, which is expensive if the mixing chamber is destroyed, and could be
dangerous.
H o w e v e r , it m u s t be emphasized that m a n u f a c t u r e r s design this part
of the i n s t r u m e n t to be as safe as p o s s i b l e u n d e r f l a s h b a c k c o n d i t i o n s .
Therefore, in m a n y ways it is probably better to have a separate air supply to
the AAS.
T h i s i n s t r u m e n t a l s o has to be p r o v i d e d w i t h a v e n t i l a t i o n h o o d to
remove gases formed during operation, particularly if nitrous oxide is used as
the fumes are very toxic.
Utility services require a large space but need to be concealed for aesthetic
r e a s o n s , y e t r e q u i r e an e a s y a c c e s s for r e p a i r p u r p o s e s .
To s a t i s f y t h e s e
conflicting demands, the main runs may be in voids above false ceilings and in
floor ducts.
Secondary services are then run to outlet points on benches taken
from floor level along the wall behind benches in voids especially incorporated
in the design of the bench fittings.
Frequent access points are provided for
maintenance purposes.
Drain pipes should be of high density polythene or copolymer polypropylene with
screwed joints.
T h e s e s h o w g o o d r e s i s t a n c e to m o s t o r g a n i c and i n o r g a n i c
chemicals.
The d r a i n a g e l i n e s m a y be e m b e d d e d in the f l o o r i n g . As it is not
acceptable to discharge laboratory w a s t e s d i r e c t l y i n t o t h e s e w e r a g e s y s t e m ,
all w a s t e from l a b o r a t o r y sinks and o t h e r w a s t e f i t t i n g s s h o u l d be led f i r s t
into dilution pots (about 5 litre capacity) before being released into the m a i n
sewers.
Buildings can be designed to include a large dilution tank where all
l a b o r a t o r y sink w a s t e is d i r e c t e d b e f o r e e n t e r i n g the s e w e r a g e s y s t e m .
For
laboratories with high mineral acid use, sink traps of inert duriron often work
well.
17
3.8
Design
References
1.
B e c k , H. L u f t u n g s e i g e n s c h a f t e n von L a b o r a b z u g e n ( V e n t i l a t i o n p o w e r of
laboratory fume cupboard).
Weinheim, Chemie-Ingenieur-Technik, 1964 (No.
3 6 ) (in G e r m a n ) .
2.
Be r u f s g e n o s s e n s c h a f t fur d i e c h e m i s c h e I n d u s t r i e , R i c h t l i n i e n fur
c h e m i s c h e L a b o r a t o r i e n Nr. 12 ( D i r e c t i v e s for c h e m i c a l l a b o r a t o r i e s no.
12) Weinheim, Verlag-Chemie, 1972 (in German).
3.
4.
Decken,
C.B. v.d. a n d
B. H u n d o r f .
Untersuchungen
uber
die
stromungstechnischen Vorgange in der Kapelle eines Laborabzug (Experiments
about flow within the cabin of a fume cupboard).
Darmstadt, GIT 1968 (No.
8) (in G e r m a n ) .
5.
(German
Federal
a.
piping)
b.
c.
experience:
6.
Druckgasverordnung
(in G e r m a n ) .
7.
Dunkl/Geyer.
R a t i o n a l e L o s u n g e n von L a b o r b a u und L a b o r e i n r i c h tungsprob1emen
in H o c h s c h u l e n ,
Industrieunternehmumgen
und i m
Gesundheitswesen der USA (Rational solutions of problems in the design of
laboratory building and equipment for u n i v e r s i t i e s , i n d u s t r y and p u b l i c
h e a l t h in the U n i t e d States).
In B e i t r a g e zur U n i v e r s i t a t s p l a n u n g
( C o n t r i b u t i o n s to the p l a n n i n g of u n i v e r s i t i e s ) . F r a n k f u r t / M . D E C H E M A ,
1970 (Heft 6) (in G e r m a n ) .
8.
F e u r i c h , H. R o h r n e t z e fur S a u e r s t o f f , D r u c k l u f t , V a c u u m , K o h l e n s a u r e in
K r a n k e n h a u s e r n und L a b o r a t o r i e n (Service p i p i n g for o x y g e n , c o m p r e s s e d
air, vacuum and carbon dioxide in hospitals and laboratories) Darmstadt,
G I T 1 9 6 4 (nos. 8, 9 and 10) (in G e r m a n ) .
9.
D e u t s c h e I n d u s t r i e N o r m t'DIN) ( G e r m a n
Beuth-Vertrieb G m b H (all in German)
plant;
principles,
Industrial
a.
Ventilation
English).
b.
Fire resistance
4102-1970.
c.
DIN 4034-1969.
d.
Laboratory furniture;
12 912-1973.
laboratory
of building
DIN
Standard).
materials
ceramic
18
tiles
1946-1960,
and
for
Part
structural
Berlin,
(also
elements.
bench
tops.
in
DIN
DIN
e.
DIN
12-914-1973.
f.
Laboratory
1973.
g.
L a b o r a t o r y furniture; large-size
DIN 12 916-1972.
h.
i.
j.
Laboratory
1972.
k.
Heating plant,
English).
1.
m.
furniture;
smoke
fume
tiles
cupboards,
stacks.
DIN
DIN
18
tops.
DIN 12 922-1972.
dimensions.
160-1968;
DIN
part
12
923-
1 (also
in
18-225-1958.
10.
11.
/Richtlinien fur die Planung und den Bau von Laboratorien (Principles for
design and building of laboratories) Weinheim, C h e m i e - I n g e n i e u r - T e c h n i k ,
1971. (No. 11) (in German).
12.
13.
14.
15.
16.
Unfallverhutungsvorschrift:
Medizinische Laboratoriumsarbeiten (Prescription for accident prevention: work in medical laboratories) Frankfurt/M.
H G U V V ) (in German).
17.
18.
V e r b a n d D e u t s c h e r E 1 e k t r o t e c h n i k e r ( V D E ) N o r m e n (Union of G e r m a n
E l e c t r i c a l Engineers s t a n d a r d s ) O f f e n b a c h / M a i n , Federal Republic of
Germany (in German).
19.
19
Standards
Fume-Dispersal
4.
4.1
LABORATORY ADMINISTRATION
Sample Collection
and
2.
C a r r y out g e n e r a l s u r v e y s of the q u a l i t y of the food s u p p l y t h r o u g h
random sampling and analysis, samples being taken from factories, warehouses
and retailers.
3.
Monitor certain specific problem areas with regard to food safety specific foods or classes of foods for specific potential risks, (e.g. level of
metallic contaminants, pesticide residues, mycotoxins, etc.).
4.
(if needed).
5.
Inspect
food
imports.
This
is b e s t d o n e on a l l
c o n s i g n m e n t s by f o r m a l s a m p l i n g c a r r i e d out s y s t e m a t i c a l l y in
representative of the lot.
imported
a manner
6.
Formal sampling should also be done on locally produced food products
b a s e d o n t h e f o o d i n s p e c t o r s ' o b s e r v a t i o n s , or b e c a u s e a r a n d o m o r
investigatory sample under the regular programme was unsatisfactory, or because
the product is one that requires thorough surveillance.
Analysis of formal and
informal samples is also necessary in an emergency such as an outbreak of foodpoisoning .
National sampling programmes yield important benefits in terms of efficiency.
The I n s p e c t o r a t e and the L a b o r a t o r y a s s i s t e d and g u i d e d by o t h e r a g e n c y
o f f i c i a l s or an a d v i s o r y b o a r d , as a p p r o p r i a t e , should p e r i o d i c a l l y plan
overall programmes to locate and deal with different problems in the areas of
food q u a l i t y and c o n s u m e r p r o t e c t i o n .
In each case the o b j e c t i v e s of the
p r o g r a m m e should be clearly defined.
A l t h o u g h s a m p l e s m a y be c l a s s i f i e d in a n u m b e r of w a y s , it is c o n v e n i e n t to
consider two broad divisions, "formal" samples and "informal" samples.
Formal
samples are those taken to determine if the foods comply with national or local
l a w s or r e g u l a t i o n s .
R e g u l a t o r y a c t i o n m a y r e s u l t from r e p o r t s r e c e i v e d on
such samples.
Informal samples may be taken for purposes of monitoring or as
part of survey work. Formal follow-up samples can be taken if informal samples
receive adverse laboratory reports.
Formal or informal samples will also be
taken under other circumstances, such as a follow-up to a consumer complaint.
When samples are
of the nature and
required from the
e x p e r i e n c e , from
from the r o u t i n e
20
4.2
Assignment
W h e n a food s a m p l e is r e c e i v e d for a n a l y s i s , t h e r e m u s t be a s y s t e m to t r a c k
the sample throughout it's initial storage, analysis and later reserve storage.
This is usually embodied in a record keeping system which is keyed to a unique
n u m b e r a s s i g n e d to the s a m p l e at the t i m e of s a m p l i n g .
T h i s n u m b e r c a n be
sequential (i.e. 0001 to 9999) or can be devised to give information (i.e. 0245 - 0 7 , the 2 4 t h s a m p l e t a k e n in 1 985 u n d e r s a m p l i n g p r o g r a m m e n u m b e r 7).
The
r e c o r d m u s t s h o w each m o v e m e n t of a s a m p l e , its r e c e i p t , a s s i g n m e n t to a
l a b o r a t o r y p e r s o n for a n a l y s i s , r e t u r n to the s a m p l e c u s t o d i a n , and e v e n t u a l
disposition.
One of the a d m i n i s t r a t i v e s t a f f s h o u l d be g i v e n this r e c o r d
keeping function and closely supervised by a senior administrator, as well as
supervised in general by the laboratory Head.
It is usually best to use a card record system rather than a log book as cards
are more flexibly handled and may be filed in groups under different headings.
M a n y card record systems have been devised including 5x8 cards with coded sites
on the periphery for punching.
Other cards are pre-printed with spaces to be
filled in w i t h appropriate data.
Regardless of the card system selected, there
are certain items of information which should be on each card:
1.
Sample
number.
2.
Product
3.
Date
4.
Date received
5.
Type of sample
6.
Method
7.
Storage
8.
Date assigned
9.
To whom assigned
name.
sampled.
at the
laboratory.
(survey, complaint,
of storage
etc.).
(dry, refrigeration,
location (coded
for
for easy
freezing,
etc.).
finding).
analysis.
(the analyst
10.
Date returned
(from
11.
12.
Reserve
13.
Final disposition
should
initial
to show
receipt).
analyst).
(may be different
storage method
and
from
the original
analyst).
location.
or disposal
of sample, method
21
and
date.
Note that the above uses the sample record only to record physical m o v e m e n t and
location, not analytical results.
The reason is that the analytical worksheet
and the sample record are usually in two different locations.
T h e s a m p l e r e c o r d card s h o u l d be p r e p a r e d and in the c u s t o d y of one p e r s o n
until the reserve sample is destroyed.
This person is often called the Sample
Custodian and in small laboratories could have other duties as well.
The job
of S a m p l e C u s t o d i a n is c r i t i c a l to the o p e r a t i o n of m o s t l a b o r a t o r i e s .
The
person employed in this post m u s t be very reliable, but m a y find the duties of
the job s l i g h t l y m o n o t o n o u s .
C o m b i n i n g the d u t i e s of s a m p l e c u s t o d i a n w i t h
k e e p i n g the l a b o r a t o r y s t o r e is o f t e n d o n e in m e d i u m
or l a r g e r
sized
laboratories.
The laboratory store of chemicals, glassware and other fittings
r e q u i r e s c a r e f u l c o n t r o l as d o e s r e o r d e r i n g of m a t e r i a l s in s h o r t s u p p l y ,
issuance of supplies to analysts, etc.
Combining the jobs of Sample Custodian
and S t o r e K e e p e r c a n c r e a t e a c h a l l e n g i n g and i n t e r e s t i n g p o s t .
Another
approach to the job of Sample Custodian in smaller laboratories is to split the
job b e t w e e n several people with different senior assistants under the various
section leaders being responsible for samples from a particular source, or for
particular groups of products.
W h e n a s a m p l e is a s s i g n e d , the a n a l y s t s h o u l d p h y s i c a l l y sign or i n i t a l the
s a m p l e c a r d to s h o w c u s t o d y .
W h e n a s a m p l e r e s e r v e is r e t u r n e d to the
C u s t o d i a n , the C u s t o d i a n w o u l d sign or i n i t i a l .
A f t e r a s s i g n i n g the s a m p l e ,
the S u p e r v i s o r m u s t h a v e s o m e m e a n s of t r a c k i n g s a m p l e s u n d e r a n a l y s i s w i t h
proposed or possible completion dates.
The sample card could be used for this.
The card would then be in the hands of the Supervisor during analysis and would
be returned to the Custodian on completion.
4.3
Sample Storage
and
Disposal
S a m p l e s t o r a g e , b o t h i n i t i a l and r e s e r v e , is c r i t i c a l to a s a m p l e a n a l y s i s .
Improper storage can completely i n v a l i d a t e a n y a n a l y t i c a l r e s u l t s .
Ideally,
the s a m p l e is to be s t o r e d in a m a n n e r to p r e v e n t a c h a n g e in the a t t r i b u t e
being examined, from the time of sampling, through analysis, and into reserve
storage.
To i l l u s t r a t e the i m p o r t a n c e of p r o p e r s t o r a g e , if a fresh food
sample to be examined for decomposition is not hard frozen until examination,
it very likely will decompose even further.
The analyst is then not sure how
m u c h of the d e c o m p o s i t i o n found is due to sample mishandling.
The usual storage areas are dry (room temperature storage), refrigeration and
freezing.
K e e p in m i n d t h i n g s that c a n h a p p e n d u r i n g s t o r a g e .
For e x a m p l e ,
insects or other vermin can attack dry storage, mould frequently occurs during
refrigeration, and frozen products often have "freezer burn" where the food has
desiccated.
Steps to m i n i m i z e these problems include using correct containers
(i.e. glass or m e t a l for dry storage, no paper bags), proper sample preparation
(i.e. g l a z i n g f r o z e n s a m p l e s w h e r e p o s s i b l e , to r e d u c e d e h y d r a t i o n ) , and
frequent checks on those stored samples which are m o s t subject to change.
Sample disposal is, or can be, a relatively simple matter.
The only problems
arise w h e n there is a hazard involved in the destruction, or where the sample
r e m a i n s must have special treatment.
An e x a m p l e is a s a m p l e of g r o u n d n u t s
heavily contaminated with aflatoxin.
The sample itself presents a hazard to
the disposer and may be a hazard to others if not detoxified.
The analyst best
k n o w s any h a z a r d s i n v o l v e d , so s h o u l d i n f o r m the S a m p l e C u s t o d i a n of a n y
special disposal requirements.
22
4.4
Budget
4.5
Purchasing
with
the
23
24
f r e i g h t , l o a d i n g c h a r g e s , d o c u m e n t a t i o n or e x p o r t h a n d l i n g , all of w h i c h are
charged separately.
The term f.a.s. is used to denote "free alongside ship".
If a b i d d e r d e v i a t e s from the t e r m s laid d o w n in the t e n d e r i n v i t a t i o n , h i s
o f f e r s h o u l d be c a r e f u l l y e x a m i n e d as it m a y h a v e b e e n i n t e n d e d to o b t a i n a
superficial advantage in price comparison only.
A careful technical scrutiny
of the s p e c i f i c a t i o n s g i v e n in a b i d d e r ' s o f f e r and a c o m p a r i s o n w i t h the
i l l u s t r a t e d l i t e r a t u r e a t t a c h e d to the bid w i l l , in m a n y c a s e s , e l i m i n a t e
q u o t a t i o n s w h i c h at f i r s t g l a n c e look c h e a p e r .
Accessories may have been
p u r p o s e l y left out to g a i n an a d v a n t a g e over o t h e r b i d d e r s .
Sometimes minor
b u t i m p o r t a n t d i f f e r e n c e s in p e r f o r m a n c e d a t a c a u s e c o n s i d e r a b l e
price
variations.
M a n y n a t i o n a l and i n t e r n a t i o n a l o r g a n i z a t i o n s i n v i t e o f f e r s from o r i g i n a l
manufacturers only, demand ing that the c o m m i s s ion usually allowed to agents be
offered as a discount.
The disadvantages of this procedure are that orders are
quite frequently placed w i t h firms which readily accept these conditions but
which have neither experience nor agents in the purchasing country.
Thus, the
scientists in less industrali zed countries are denied the benefit of any kind
of t e c h n i c a l a s s i s t a n c e .
W h e n c o m p a r i n g p r i c e q u o t a t i o n s , the o f f e r of an
i n t e r n a t i o n a l l a b o r a t o r y e q u i p m e n t s u p p l i e r m a y o c c a s i o n a l l y be found to b e
substantially higher than that of a manufacturer.
In such cases it can only be
r e c o m m e n d e d t h a t the e x p e r i e n c e and a f t e r - s a l e s s e r v i c e i n c o r p o r a t e d in the
offer should be carefully considered.
One aspect of equipment purchase that causes problems is the time given for the
s u b m i s s i o n of o f f e r s .
O f t e n it is far too s h o r t .
It s h o u l d be r e a l i z e d t h a t
long lists of specifications prepared for a project over an extended period of
time cannot normally be quoted for in a space of only two or three weeks - the
t i m e that m i g h t be left to a s u p p l i e r a f t e r d e l a y s in m a i l are t a k e n into
account.
The q u a l i t y of o f f e r s m i g h t be c o n s i d e r a b l y i m p r o v e d if m o r e t i m e
were allowed.
D e c i s i o n s on bid a c c e p t a n c e s h o u l d n o t be d e l a y e d b e y o n d the
n o r m a l validity of offers.
Another serious problem that is often encountered concerns damage in transit
Extensive d a m a g e and even total loss
and the insurance covering such damage.
can result from the rough handling of consignments in ports where no mechanized
m e a n s of t r a n s p o r t (such as f o r k - l i f t t r u c k s ) is a v a i l a b l e .
D e l a y s m a y be
e n c o u n t e r e d in c l e a r i n g c o n s i g n m e n t s t h r o u g h c u s t o m s , and s h e l t e r e d s t o r a g e
facilities are often quite inadequate.
Cases containing expensive equipment
m a y be s u b j e c t e d to the m o s t a d v e r s e c l i m a t i c c o n d i t i o n s - h u m i d i t y , h e a v y
tropical rains, extreme heat and dust.
No economically justifiable method of
p a c k i n g can p r e v e n t d a m a g e to e q u i p m e n t u n d e r such c o n d i t i o n s .
Sometimes,
b e c a u s e of c u s t o m s f o r m a l i t i e s and a d m i n i s t r a t i v e d e l a y s in h a v i n g the
consignments unpacked and examined, insurance coverage has already expired by
the t i m e the e q u i p m e n t a r r i v e s at its d e s t i n a t i o n and a c l a i m can be l o d g e d .
T h e n , m o r e t i m e and e f f o r t is u s u a l l y s p e n t on f i x i n g r e s p o n s i b i l i t y than on
how the situation might be avoided in the future.
Replacement parts required to repair transport damage should be obtainable with
a m i n i m u m of delay and administrative red tape.
Laboratories should have the
authority, in an emergency, to place small orders direct with suppliers.
With
or without such emergency order facilities, h o w e v e r , scientists usually depend
on (and prefer cooperation with) the experienced and flexible supplier who is
in regular contact w i t h his customer, who extends unbureaucratic help and who
even provides, when necessary, free replacements and repair facilities in order
to c o n t r i b u t e to the p r i m e o b j e c t i v e in the e s t a b l i s h m e n t of a s c i e n t i f i c
institute, useful and effective work and uninterrupted operation.
25
4.6
Supplies
Management
Name of product
Date purchased
Where purchased
Amount (including units if more than one
Expiration date (if any)
Special storage requirements (if any)
Amount dispensed.
container)
S m a l l m e t a l t a g s p a i n t e d w i t h b r i g h t c o l o u r s can be p u r c h a s e d and d i f f e r e n t
tags affixed to cards for flagging purposes.
For e x a m p l e , a red tag m a y m e a n
the supply is low and should be reordered within a given time.
Having a w o r k a b l e supplies m a n a g e m e n t s y s t e m t e n d s to p r e v e n t c i r c u m s t a n c e s
w h e r e a n a l y s e s h a v e s t o p p e d b e c a u s e a c r i t i c a l m a t e r i a l is s u d d e n l y u s e d up.
L i k e b u d g e t i n g , it is a p r o c e s s of m a i n t a i n i n g c o n t r o l of a c r i t i c a l a r e a to
promote overall smooth operation of the laboratory.
4.7
Equipment
Maintenance
W h e n the food analyst goes beyond organoleptic examinations, he or she must use
s o m e i t e m of e q u i p m e n t to p r o c e s s or to m e a s u r e the s a m p l e a t t r i b u t e of
interest.
It is critically important, therefore, that all items of equipment
be properly and promptly maintained, and repaired when needed.
T h e d e g r e e of s o p h i s t i c a t i o n of e q u i p m e n t v a r i e s d r a m a t i c a l l y from a
straightforward pH m e t e r to a complex spectrophotometer.
M a n y laboratories in
developing
countries have great difficulty
in o b t a i n i n g r e p a i r of any
e q u i p m e n t , sophisticated or otherwise.
It is therefore
reasonable to require
that proper maintenance of the equipment be routinely scheduled and completed,
hopefully to delay the day when outright repairs are necessary.
T h e b e s t c i r c u m s t a n c e , of c o u r s e , is to e s t a b l i s h an o p e r a t i n g r e p a i r and
m a i n t e n a n c e w o r k s h o p w i t h qualified technical staff.
This can be essential for
l a r g e i n s t i t u t e s h a v i n g a d i s p r o p o r t i o n a t e l y l a r g e i n v e s t m e n t in e x p e n s i v e
equipment.
E v e n in the a b s e n c e of an o r g a n i z e d w o r k s h o p , s o m e a n a l y s t s or
technicians can be given training in repair and maintenance techniques, often
by local instrument suppliers.
If adequate service is available locally, serious consideration should be given
to purchase of service contracts.
The usual service contract involves checking
the e q u i p m e n t at s p e c i f i e d i n t e r v a l s and p e r f o r m i n g n e c e s s a r y m a i n t e n a n c e .
E m e r g e n c y r e p a i r s are u s u a l l y d i s c o u n t e d in p r i c e b e c a u s e of the s e r v i c e
contract.
Service contracts are especially important for analytical balances,
to m a i n t a i n proper calibration.
A history of an instrument's maintenance and repair can become very important.
It p r o v i d e s a s u m m a r y of the i n s t r u m e n t ' s o p e r a t i o n o v e r a g i v e n p e r i o d , b u t
m o r e i m p o r t a n t l y , it can p r o v i d e a j u s t i f i c a t i o n for r e p l a c e m e n t of old and
o u t w o r n items.
Recording the cost is important as it is then readily apparent
26
w h e n an i n s t r u m e n t c o s t s m o r e to k e e p o p e r a t i n g t h a n it is w o r t h .
A preprinted
5 x 8 c a r d c a n c o n v e n i e n t l y b e u s e d to r e c o r d s u c h i n f o r m a t i o n .
An e x a m p l e of
s u c h a c a r d ( f r o n t a n d r e a r ) is s h o w n in F i g u r e s 4.1 a n d 4 . 2 .
T y p e of Machin*
MACHINE
PART I -
DETAILS
OF
HISTORY
CARD
MACHINE
B r a n d a n d Modal N o .
Vendor
L o c a t i o n of m a c h i n e
(State dept./scction)
H o w o p e r a t e d ( T i c k in appropriate b o x )
Machine N o .
C o u n t r y of Manufacture
Data of P u r c h a i e
Purchase Price
Guarantee P e r i o d
T e r m s of Guarantee
P A R T II -
Manual
Etactrk
Electronic
DETAILS OF MAINTENANCE
Service A g e n t
Per lOd
Maintenance C o n t r a c t
Name
From
Cott ($)
(per a n n u m )
To
Spare parts
included?
Yes
No
N u m b e r of
C o m m e n t o n f i r m ' service
(per a n n u m )
Figure 4.1
Front Side
F A R T HI -
OF
BREAKDOWNS
S e r v i c i n g / R e o a i r details
(State cause of b r e a k d o w n a n d
parts c h a n g e d , etc!
Date
P A R T IV
OETAILS
COMMON D E F E C T S
I d n c n b * with d . u i l i
pm
Response
time of
Service A g e n t
f r * j . n y . cHactsl
Figure 4.2
Rear Side
27
Cumulative
Cost
C o s t of
Repair
Time taken
to repair
4.8
Housekeeping
4.9
Training
28
5.
5.1
LABORATORY
OPERATIONS
Workplans
T h e a n n u a l w o r k p l a n is the c o r n e r s t o n e to m a n a g i n g a food c o n t r o l l a b o r a t o r y .
It p r o v i d e s a m e a n s of e s t i m a t i n g s t a f f a n d r e s o u r c e s n e c e s s a r y to do a f i x e d
n u m b e r of a n a l y s e s .
C o n v e r s e l y , g i v e n a f i x e d s t a f f , the w o r k p l a n can e s t i m a t e
h o w m u c h w o r k can be d o n e .
W o r k p l a n d a t a is a l w a y s o n l y an e s t i m a t e , a l t h o u g h its a c c u r a c y o f t e n
w i t h u s e d u e t o r e f i n i n g o f t i m e m o d u l e s u s e d in c a l c u l a t i o n s .
i m p o r t a n t t i m e m o d u l e s in w o r k p l a n n i n g are:
improves
The two
1.
T h e a n a l y s t p r o d u c t i v e y e a r : T h i s is t h a t t o t a l t i m e i n a n a v e r a g e
year that one a n a l y s t s p e n d s doing o n l y s a m p l e a n a l y s i s .
Time spent during
w o r k h o u r s d o i n g o t h e r t h i n g s is d e d u c t e d .
A n e x a m p l e of t h e d e t e r m i n a t i o n of
t h i s m o d u l e is as f o l l o w s :
Total
time a v a i l a b l e
(based
on 4 0 h o u r w o r k
week)
2080 hr s
time
(2080 -
80
40
80
200
80
400
880
hr s
hrs
hr s
hrs
hrs
hrs
hrs
1200 hrs
880)
laboratory
can
T h e a b o v e t i m e d e d u c t i o n f i g u r e s w e r e t a k e n for e x a m p l e p u r p o s e s o n l y .
Each
i n d i v i d u a l l a b o r a t o r y w i l l be d i f f e r e n t .
In d e t e r m i n i n g d e d u c t i o n s , c o n s i d e r
the f o l l o w i n g :
a.
Holiday
time
is u s u a l l y
fixed
b.
I l l n e s s and p e r s o n a l t i m e a v e r a g e s can be t a k e n f r o m
staff
The
a d m i n i s t r a t i v e r e c o r d s f o r t h e p r e c e e d i n g o n e or t w o y e a r s .
a v e r a g e of the p r e v i o u s y e a r is b e s t u s e d as the m o d u l e . T h e r e a s o n
is that the s t a f f u s u a l l y h a v e m o r e p e r s o n a l t i m e m a d e a v a i l a b l e to
t h e m as t h e i r s e n i o r i t y i n c r e a s e s .
c.
M a n a g e m e n t m u s t d e c i d e h o w m u c h t i m e w i l l be set a s i d e e a c h y e a r for
t r a i n i n g . N o t e in the e x a m p l e t h a t t r a i n i n g t i m e is a b o u t 10% of the
t o t a l . If the s t a f f is r e l a t i v e l y y o u n g and i n e x p e r i e n c e d , m o r e t i m e
w i l l be r e q u i r e d .
C o n v e r s e l y an a l l - s e n i o r s t a f f m a y r e q u i r e l e s s .
d.
A d m i n i s t r a t i v e t i m e is d i f f i c u l t to e s t i m a t e as t h e r e are u s u a l l y few
or no r e c o r d s to go b y .
It i n c l u d e s t i m e a s a c t i n g
supervisor,
general
library reading,
and o t h e r a s s i g n e d
or
incidental
administrative activities.
e.
O t h e r n o n - a n a l y s i s t i m e is also o n l y an e s t i m a t e , a l t h o u g h s o m e t i m e
r e c o r d s m a y be a v a i l a b l e .
It i n c l u d e s g e n e r a l r e s e a r c h o r m e t h o d
development
activities,
quality
assurance
work,
equipment
m a i n t e n a n c e , t i m e s p e n t s e r v i n g as a t r a i n e r , a n d a n y o t h e r n o n a n a l y s i s w o r k time not included e l s e w h e r e .
29
by government
policy.
2.
T h e a n a l y t i c a l h o u r s r e q u i r e d per s a a p l e :
The f i r s t step is to
d e f i n e w h a t is i n c l u d e d in a s a m p l e a n a l y s i s , as t h i s o b v i o u s l y a f f e c t s the
total time.
Activities which are suggested to be included are:
a.
preparation.
b.
Analysis.
c.
M e t h o d d e v e l o p m e n t or p r o b l e m s o l v i n g r e q u i r e d of a g i v e n s a m p l e .
(As o p p o s e d to g e n e r a l d e v e l o p m e n t or r e s e a r c h , w h i c h w o u l d b e
included in non-analysis time.)
d.
S t a n d a r d i z a t i o n a c t i v i t i e s r e l a t e d to a g i v e n s a m p l e .
standard solutions and curves for example.)
e.
Preparation
of analytical
report and
(Preparing
calculations.
The next step is to prepare a list of all the different analyses conducted and
e s t i m a t e individual analytical times based on experience.
If some analyses are
d o n e b y t e a m s in a p r o d u c t i o n - 1 i n e a r r a n g e m e n t , e s t i m a t e the t o t a l t i m e
required by totalling the time and correcting to an individual analyst basis.
For e x a m p l e , if 4 analysts working as a team can produce 32 completed samples
in an 8 h o u r p e r i o d ,
t h e n t h e a v e r a g e a b s o l u t e s a m p l e t i m e is 0.25
hours/analysis.
H o w e v e r , it required 4 analysts and to correct the time to an
i n d i v i d u a l a n a l y s t b a s i s - 4 x 0.25 = 1.0 h o u r s / ana 1 ys i s . T h i s w o u l d be the
figure used in calculations.
*
The laboratory is now able to make good estimates on what and h o w m u c h work can
be d o n e .
It is a s i m p l e m a t t e r of m u l t i p l y i n g the n u m b e r s of a n a l y s t s
a v a i l a b l e d u r i n g the y e a r t i m e s the p r o d u c t i v e y e a r t i m e m o d u l e to g a i n the
total analytical hours available.
This can then be spread among the types of
a n a l y s e s to be d o n e , u s i n g the h o u r s / a n a l y s i s m o d u l e s .
A l t h o u g h m a n y of the
m o d u l e s are e s t i m a t e s , it is still a better and m o r e accurate w a y to d e t e r m i n e
w h a t can be d o n e , than r e l y i n g on m e m o r y and s h e e r g u e s s e s .
( R e g a r d i n g the
n u m b e r s of a n a l y s t s a v a i l a b l e d u r i n g the y e a r , k e e p in m i n d t h a t t h i s m a y
change by new hires or projected losses, so include these future projections in
the annual estimate).
T h e a b o v e c a l c u l a t i o n m e c h a n i c s of a w o r k p l a n do not a d d r e s s the m e a n s of
d e c i d i n g the a n n u a l w o r k p r i o r i t i e s .
T h i s is u s u a l l y d o n e in p a r t b y
organizational policy and in part by m e e t i n g s of senior operational managers,
s u c h as the L a b o r a t o r y and I n s p e c t o r a t e H e a d s .
All p l a n n e d w o r k and t i m e
modules depend on proper work scheduling and flow.
If samples are collected
too fast or too slow, the laboratory efficiency suffers.
There m u s t therefore
be an extremely close working relationship and liaison b e t w e e n the inspectorate
and l a b o r a t o r y .
No work plan would be complete without some form of contingency planning.
The
o l d a d a g e s t a t e s t h a t , "... If s o m e t h i n g c a n go w r o n g , it w i l l
...".
T h e r e f o r e , t h e r e s h o u l d be at least a p r o v i s i o n in a a n n u a l w o r k p l a n for
e m e r g e n c i e s or u n e x p e c t e d p r o b l e m s .
A m a j o r p u b l i c h e a l t h d i s a s t e r , for
e x a m p l e , could require an all-out laboratory effort, negating workplan work for
some period of time.
The contingency plan would simply and clearly state w h a t
t y p e s of a n a l y s e s ( u s u a l l y the l o w e s t p r i o r i t y ) w o u l d be e l i m i n a t e d in the
event of an emergency.
30
5.2
Priorities
for
General analytical
laboratory policy.
Analysis
Priority 1
Poisonings or
public health
Priority 2
K n o w n or
resulting
Priority 3
Informational
injury complaints
analyses.
s u s p e c t e d law or
in direct injury.
surveys
and
health
other
emergency
violations,
or
not
work.
M o s t of the w o r k of a l a b o r a t o r y is u s u a l l y in the t h i r d p r i o r i t y c a t e g o r y ,
with a smattering of priority two and only infrequently, priority one.
W i t h i n a g i v e n p r i o r i t y , the w o r k c a n be s u b - g r o u p e d by r e l a t i v e i m p o r t a n c e .
It is conceivable that work of very low importance never gets done because of
the continuing press of higher priority analyses.
If it appears that such is
the c a s e , the s u p e r v i s o r m u s t a d v i s e the H e a d of the p r o b l e m s and s u g g e s t
r e v i s i o n of the p l a n n e d w o r k load for the s u p e r v i s o r ' s g r o u p .
The w o r k p l a n s
discussed in the previous Section often undergo mid-year or periodic revision
based on such happenings.
5.3
Analysis
Assignaient
31
e x p e r i m e n t a l d e t a i l s in the m e t h o d as published.
R e f e r e n c e to the source w i l l
usually resolve such difficulty.
It is n o t a l w a y s n e c e s s a r y
to u s e a
collaborated method.
H o w e v e r , s u c h m e t h o d s s h o u l d be f i r s t c h o i c e if the
p a r a m e t e r is b e i n g d e t e r m i n e d in t h e l a b o r a t o r y f o r t h e f i r s t t i m e or if a
p r o d u c t has not been a n a l y z e d p r e v i o u s l y .
It is i m p o r t a n t to f o l l o w the
p r o c e d u r e s ior v a l i d a t i n g a m e t h o d .
M a n y o t h e r m e t h o d s m a y be e q u a l l y g o o d ,
but m a y not, for v a r i o u s reasons, have been subjected to c o l l a b o r a t i v e studies
or r u g g e d n e s s t e s t s .
As a r e s u l t
the a n a l y s t m a y run into
unexpected
d i f f i c u l t i e s if he h a s to t a k e the m e t h o d d i r e c t l y f r o m a b o o k .
If a m e t h o d
has b e e n in use and found to give r e l i a b l e results it should not be changed for
another
until
the n e w m e t h o d
has been s h o w n
to be of e q u a l or b e t t e r
r e l i a b i l i t y in that p a r t i c u l a r l a b o r a t o r y ( i r r e s p e c t i v e o f i t s c o l l a b o r a t i v e
status).
C o n s i d e r a b l e stress is quite r i g h t l y put on c o l l a b o r a t i v e testing at
the p r e s e n t t i m e , but it should not be f o r g o t t e n that a r e l i a b l e m e t h o d is only
a p r e c o n d i t i o n to o b t a i n i n g the r i g h t a n s w e r .
T h e a b i l i t y of the a n a l y s t to
use the m e t h o d
is the e s s e n t i a l r e q u i r e m e n t
and the p e r s o n t a k i n g
the
r e s p o n s i b i l i t y for the result, w h e t h e r the analyst h i m s e l f or the s u p e r v i s o r ,
m u s t be c o n f i d e n t of this.
5.4
Analysis
Control
C o n t r o l is a v e r y i m p o r t a n t s u p e r v i s o r y f u n c t i o n .
It is n o t s u f f i c i e n t to
s i m p l y a s s i g n w o r k and w a i t for r e s u l t s .
T h e r e m u s t be s o m e type of a c t i v e
control in the form of expected c o m p l e t i o n datas, f o l l o w - u p i n q u i r i e s , or other
i n d i c a t i o n s of active interest.
This does not m e a n p e e r i n g over the a n a l y s t ' s
s h o u l d e r , but it does m e a n that the s u p e r v i s o r has c e r t a i n fixed e x p e c t a t i o n s
on w o r k c o m p l e t i o n and e n f o r c e s those e x p e c t a t i o n s .
T h e r e are several m e t h o d s of control but one of the m o r e e f f e c t i v e is also one
of the s i m p l e s t .
The s u p e r v i s o r p r e p a r e s a card for each a n a l y s t .
When a
s a m p l e is a s s i g n e d to the a n a l y s t , the s a m p l e n u m b e r is r e c o r d e d on the c a r d
along w i t h a p r o j e c t e d date of c o m p l e t i o n .
W h e n an a n a l y s i s report is r e c e i v e d
the entry is lined through.
W h e n a'card has been filled, it is discarded and a
n e w one p r e p a r e d .
The p r o j e c t e d c o m p l e t i o n d a t e r e p r e s e n t s t h e s u p e r v i s o r ' s
e s t i m a t e of an a c c e p t a b l e analysis t i m e , a s s u m i n g no p r o b l e m s .
The s u p e r v i s o r
s c a n s t h e c a r d s of a l l a n a l y s t s e v e r y d a y or so a n d if a d a t e h a s e x p i r e d b u t
no report r e c e i v e d , the supervisor inquires of the s a m p l e status.
The analyst
m a y be h a v i n g d i f f i c u l t y a n d h a d n o t m e n t i o n e d it.
A f t e r d i s c u s s i o n , the
s u p e r v i s o r d e c i d e s if a n a l y s i s s h o u l d c o n t i n u e and if so, a s s i g n s a n e w
projected c o m p l e t i o n date.
The s u p e r v i s o r m u s t also a s s i g n n e w dates w h e n
ongoing w o r k m u s t be interrupted by a s s i g n m e n t of h i g h e r p r i o r i t y analyses.
5.5
Analysis
Reporting
32
from Roman and c o m m o n law that the report or certificate of the analyst assumes
greater importance.
U n d e r b o t h R o m a n and U.S.A. l a w the e n t i r e l a b o r a t o r y
records relating to the sample must be capable of wi ths tand ing the scrutiny of
the c o u r t and d e f e n s e l a w y e r s .
The p r a c t i c a l e f f e c t of t h e s e d i f f e r e n c e s is
not great. Under any system it is necessary for the regulatory chemist to have
legally impeccable laboratory data records and to report against samples in a
w a y that is u n d e r s t a n d a b l e to the l a y m a n , b r i e f , s u c c i n c t , and free from
irrelevancy.
T h e f o r m a t of an a n a l y s i s r e p o r t is d i c t a t e d by the a d m i n i s t r a t i v e and legal
needs of the organization.
The report form should be preprinted with blocks or
l i n e s of i n f o r m a t i o n p l a c e d in d e s i g n a t e d a r e a s on the f o r m .
This p e r m i t s
faster and m o r e uniform write-up, as well as easier final review (the reviewer
knows where to look on the form for different information).
A complete report
form would have spaces for the following information:
Sample number
Product name
Product description and amount
Date received for analysis
Labelling (if any)
Analysis method used
Analysis results
Reserve product amount
Date completed
Total analysis time in hours (if needed
for time
modules).
Raw work data and standardization information can be placed on the reverse side
of the analysis report or can be kept separately in notebooks.
In any case it
s h o u l d be a c c e s s i b l e to the r e v i e w e r in the e v e n t of q u e s t i o n .
It is b e s t to
include all raw data so that the entire sequence of work can be reconstructed
later if needed.
Calculations m u s t be clear w i t h all equations stated.
There
is no w a y to d e t e r m i n e if a c a l c u l a t i o n is c o r r e c t w i t h o u t c h e c k i n g the
T h i s , of c o u r s e , m e a n s
c a l c u l a t i o n s y s t e m u s e d , as w e l l as the a r i t h m e t i c .
that all dilutions or other operations affecting the final calculation must be
clearly stated in the raw data.
R e s u l t s m u s t a l w a y s be r e p o r t e d o n l y to a n u m b e r of s i g n i f i c a n t
figures
j u s t i f i e d by the a c c u r a c y and p r e c i s i o n of the m e t h o d .
In g e n e r a l , it is
p r u d e n t to r e p o r t to as few s i g n i f i c a n t f i g u r e s as p o s s i b l e c o n s o n a n t w i t h
stating the facts the report has to convey.
For e x a m p l e , for most purposes it
m a y be a d e q u a t e to r e p o r t a s a m p l e as c o n t a i n i n g "not less ( m o r e ) than 70
percent of y".
The report m u s t be clear and confined to factual information,
and statements which cannot be substantiated must not be made.
5.6
Analysis
Review
33
5.7
Method
Validation
5.8
Confirming
Analysis
W h e n an o r i g i n a l a n a l y s i s s h o w s the s a m p l e to be in v i o l a t i o n of l a w or
regulations in some m a n n e r , the supervisor m u s t decide if a second analysis by
the o r i g i n a l a n a l y s t is n e e d e d .
T h i s s h o u l d o n l y be d o n e if t h e r e is s o m e
doubt that the original analysis w a s done correctly.
In the event that there are no apparent errors in the original analysis, then a
c o n f i r m i n g a n a l y s i s b y a s e c o n d a n a l y s t s h o u l d be d o n e as f o l l o w s :
A fresh
p o r t i o n of s a m p l e s h o u l d be p r e p a r e d ( u n l e s s it is n e c e s s a r y or d e s i r a b l e to
u s e the o r i g i n a l ) and a n a l y z e d u s i n g a s e c o n d m e t h o d (if p o s s i b l e ) and n e w
standard reference material.
If the a d v e r s e f i n d i n g s are r e p e a t e d by the
c o n f i r m i n g analyst, then it is extremely likely that a violation exists.
If,
h o w e v e r , t h e r e is no c o n f i r m a t i o n , then the s u p e r v i s o r m u s t m e e t w i t h b o t h
a n a l y s t s and d e c i d e w h a t is to be d o n e .
It m a y be t h a t the m e t h o d s are n o t
c o m p a t i b l e , if so a recheck using the original method might be in order.
It is
a l s o o f t e n v e r y u s e f u l to c r o s s c h e c k the s t a n d a r d s u s e d b y e a c h a n a l y s t to
ensure they compare.
Confirming analysis is basically an attempt to ensure that any violation of law
The e n f o r c e m e n t laboratory
or regulation has substance and is not a mistake.
c a n n o t a f f o r d to m a k e any m i s t a k e s , so it is n e c e s s a r y to p r o v e that all
adverse results are correct.
34
6.
6.1
The Safety
LABORATORY
SAFETY
Programme
The Head of the laboratory and supervisors must emphasize to all the laboratory
staff, their c o m m i t m e n t and d e t e r m i n a t i o n to e n s u r e s a f e l a b o r a t o r y w o r k i n g
conditions.
One staff m e m b e r s h o u l d be a p p o i n t e d the " S a f e t y O f f i c e r " and
given the responsibility to m o n i t o r safety procedures, practices and equipment
on a routine periodic basis.
In a large laboratory, the Safety Officer may be
assisted by a c o m m i t t e e of two or three analysts.
The d u t i e s of the S a f e t y O f f i c e r (and c o m m i t t e e w h e r e a p p r o p r i a t e ) s h o u l d be
d e t a i l e d in the l a b o r a t o r y S a f e t y P r o g r a m m e .
This p r o g r a m m e would indicate
safety requirements, hazards, equipment and emergency procedures.
Items which
can be included in a laboratory Safety P r o g r a m m e are discussed in the following
sections.
It should be r e m e m b e r e d that the Head h a s the final a u t h o r i t y as
w e l l as r e s p o n s i b i l i t y for l a b o r a t o r y s a f e t y , so t h a t the S a f e t y O f f i c e r m a y
only make recommendations.
6.2
Basic
Safety
Rules
equipment,
f i r s t aid
2.
Before beginning a sample analysis, review possible hazards connected
w i t h the a s s i g n m e n t and take the n e c e s s a r y p r e c a u t i o n s to e l i m i n a t e or
counteract the hazard.
3.
Use, when appropriate, the safety equipment provided for protection,
(e.g., s a f e t y g o g g l e s ; face s h i e l d s ; v a r i o u s t y p e s
of g l o v e s ) .
Wear a
laboratory coat routinely since its purpose is to serve as protective clothing.
4.
Bring all accidents and hazardous
supervisor or Head immediately.
conditions
to the attention of
the
5.
W h e n l i f t i n g h e a v y o b j e c t s , use the legs i n s t e a d of the b a c k .
Bend
the knees and hold the back straight so that the lifting effort is accomplished
w i t h the legs r a t h e r than the back.
L i f t s l o w l y to j u d g e the w e i g h t of the
object.
If too heavy, obtain assistance and/or use a lifting device.
6.
Be
jewelry (like
equipment.
entangled in
7.
T u r n off l a b o r a t o r y s e r v i c e s (gas, w a t e r , etc.) at the s e r v i c e c o c k
w h e n not in use. Changes in pressure m a y suddenly dislodge tubing connected to
an apparatus and lead to an accident or possible injury.
8.
Always use mechanical aids, such as safety bulbs
when pipetting hazardous material.
Never use the mouth.
35
or pipette
fillers,
9.
Use fume hoods for any analytical operations
of solvents, or w h e n noxious fumes will be generated.
their
10.
Keep the
contents.
work
area
neat
11.
Any chemicals, whether
m u s t be washed off immediately.
even
12.
Keep fire escape
temporarily.
routes
and
tidy,
toxic
and
13.
No one s h o u l d w o r k a l o n e
available in the event of accident.
with
or not,
doors
in the
all
which
clear
involving
large
containers
are
at all
laboratory,
labelled
spilled
times.
so that
amounts
on
the
Do not
with
hands
block,
assistance
is
14.
The last person to leave the laboratory at the end of the working day
m u s t c h e c k that all e q u i p m e n t t h a t s h o u l d be t u r n e d o f f h a s b e e n .
(This d o e s
not release each individual operator from his duty to turn off the equipment no
longer in use.)
The laboratory Head in consultation with staff m a y prefer to
operate a duty roster for opening the laboratory in the morning and closing at
the end of the w o r k i n g day.
6.3
Fire
Safety
36
6.4
Chemical
Hazards
All c h e m i c a l s s h o u l d be c o n s i d e r e d as p o t e n t i a l l y h a z a r d o u s and s h o u l d be
treated with caution.
As far as possible, dangerous c h e m i c a l s should be stored
away from the laboratory and away from others with which they violently react.
Y e l l o w p h o s p h o r u s and p i c r i c acid m u s t be k e p t u n d e r w a t e r , s o d i u m and
potassium metal under oil.
Explosive peroxides can be formed in diethyl ether.
T h e y s h o u l d a l w a y s be r e m o v e d if f o u n d to be p r e s e n t , as an e x p l o s i v e
concentration
of p e r o x i d e m a y b e f o r m e d
if t h e e t h e r is d i s t i l l e d .
Distillation should be stopped while there is plenty of solvent remaining in
the d i s t i l l a t i o n flask and care s h o u l d be t a k e n not to o v e r h e a t the flask.
D u s t m a y c a u s e the e x p l o s i v e d e c o m p o s i t i o n of h y d r o g e n p e r o x i d e of o v e r 30
percent concentration.
Peroxides in general can be explosive, and must not be
allowed to come into contact with reducing agents or f l a m m a b l e solvents.
They
should be kept in dark bottles in a refrigerator.
Hydrogen fluoride solution
is e x t r e m e l y dangerous as contact w i t h the skin may result in lesions that fail
to heal.
Disposable plastic gloves must always be worn when this solution is
being handled.
Calcium gluconate gel or solution or another antidote should be
available in the first-aid cabinet.
Toxic levels of nitrogen dioxide can be produced during the use of the nitrous
oxide-acetylene flame in atomic absorption spectrophotometry and consequently
ventilation must be good.
The recommended threshold limit value (TLV) for 40
m i n u t e s exposure is 5 ppm.
Tubes for testing contaminated air
are available
c o m m e r c i a l l y from laboratory supply firms.
It is important that bottles containing sodium and potassium (for example w h e n
these have been used for drying ether) are
not left near a washing-up area in
case an inexperienced or unobservant person attempts to wash the bottle in the
37
u s u a l way.
In fact, all c o n t a i n e r s ( b e a k e r s , e t c ) c o n t a i n i n g h a z a r d o u s
material must first be rinsed or otherwise treated by the analyst to remove the
h a z a r d , b e f o r e giving to g l a s s w a r e w a s h i n g .
The need for this is o b v i o u s
as the analyst is the only one who knows of the hazard and how to eliminate it.
All reagent bottles, flasks or other containers must be properly labelled, even
if the c o n t e n t s are c o n s i d e r e d h a r m l e s s .
A d h e s i v e w a r n i n g s t i c k e r s can be
p u r c h a s e d from c h e m i c a l s u p p l y f i r m s .
T h e s e can be used in a d d i t i o n to the
container label to highlight hazards.
When emptying acids and chromic acid cleaning solutions into the drains, first
fill the sink with water, pour the acid or cleaning solution into the sink, and
then let the w a t e r run out.
A l l o w the tap to r e m a i n on full for a few
additional minutes.
Dilution should always be sufficient to reduce the acid
concentration to less than one normal.
Store acid containers in inert trays if
the acid c o n c e n t r a t i o n is g r e a t e r than 2N. P o l y e t h y l e n e t r a y s are s u i t a b l e .
Handle concentrated ammonium hydroxide and solutions of potassium and sodium
hydroxide which are ION or above as if they were concentrated acids and observe
the s a m e p r e c a u t i o n s as for acids. Do not store A L K A L I in the s a m e tray w i t h
ACID.
Do not store concentrated alkalies in glass-stoppered bottles.
6.5
Biological
Hazards
Reference
Aflatoxins
Potent
carcinogen
6,7
Potent
carcinogen
1,2,6
Asbestos
Carc inogen
Auramine, or 4,4'dimethylaminobenzophenonimide
Suspected
carcinogen
2,6
Benzene, benzol(e)
Suspected
carcinogen
4,5,6
Benzidine,
diamide,
Potent
carcinogen
2,6
Potent
carcinogen
Suspected
Carbon
Carc inogen
4,4'-biphenyldiaminobiphenyl
tetrachloride
Suspected
salts (3 and
6+)
Carc inogen
38
3,6
carcinogen
6,9
6
carcinogen
3,6,7
Ne
Catetory
Reference
Care inogen
3,4,6
DDT
Suspected
(p,p*
or o,p')
o-Dianisidine
Care inogen
Diazomethane
Suspected
Dichloroethane
Carcinogen
4-Diethylaminoazobenzene
(Butter Y e l l o w )
Suspected
N,N-Dimethylnitrosamine
Potent
Dimethyl
Carcinogen
sulphide
1,4-Dioxane
ether
(diethylene
carcinogen
2,6
carcinogen
4,5,6
-
carcinogen
carcinogen
6,8
-
6,9
Carcinogen
Teratogen
Formamide
5,6
Suspected
carcinogen
Suspected
carcinogen
2,6
Mineral
Carc inogen
3,6
1-Naphthylamine
(1-amino-naphthalene)
Care inogen
2,6
2-Naphthylamine
(2-amino-naphthalene)
Potent
Nickel
Carcinogen
4,6
Nitrobenzene
Carcinogen
Nitrosamines
Potent
Patulin
Suspected
carcinogen
Rhodamine B
Suspected
carcinogen
Suspected
carcinogen
Magenta
acid or Acid
oils
and
fuchsin
(heavy)
salts
Sodium diethyl
Soot, carbon
dithiocarbamate
black
carcinogen
carcinogen
Carcinogen
1,2,6
3,6
Tannins
Suspected
carcinogen
5,6
Thioacetamide
Suspected
carcinogen
4,5,6
Thiourea
Suspected
carcinogen
4,5,6
Trichloroethylene
Suspected
carcinogen
Vinylchloride
Carcinogen
Zearalenone
monomer
Suspected
39
10
carcinogen
11,12
in the listing
are:
1.
2.
C h e s t e r B e a t t y R e s e a r c h I n s t i t u t e (1966).
" P r e c a u t i o n s for L a b o r a t o r y
Workers who handle Carcinogenic Aromatic Amines."
The Institute, London;
reprinted with additional notes 1971, i. 7 pp.
3.
Clayson, D.B.
4.
D e w h u r s t , F. (1972).
10, 57-85, passim.
5.
Hueper,
Cancer."
6.
7.
8.
S e a r l e , C.E. (1972).
9.
10.
Maltoni,
11.
Ueno, Y. and Kubota, K., (1976), Cancer Research, 36_ (2) 445-451.
12.
6.6
Physical
(1962).
"Chemical Carcinogenesis."
"Carcinogens
C.C. T h o m a s ,
Churchill.
in the L a b o r a t o r y . "
Carcinogenesis
and
and
other
Hazards
Glassware Handling
1.
Do not use b r o k e n or chipped g l a s s w a r e or r e t u r n it to s t o r a g e .
If
it is b e y o n d r e p a i r , d i s p o s e of it. W h e n in d o u b t r e g a r d i n g p r o p e r d i s p o s a l ,
consult the supervisor.
Always use gloves in handling broken glass.
2.
R e m o v e s h a r p or jagged e d g e s from g l a s s w a r e b e f o r e u s i n g it.
polish the edges on all glass tubing.
Fire
3.
Broken glass in sinks present a definite hazard since glass may not
be v i s i b l e in the p r e s e n c e of w a t e r .
W h e n b r o k e n in the sink, r e m o v e it
promptly.
F u r t h e r m o r e , c o n s i d e r the p o s s i b i l i t y of the p r e s e n c e of b r o k e n
glass when reaching into the sink for any purpose.
40
4.
Inserting tubing into stoppers or rubber tubing can result in serious
cuts, which can be prevented if the following precautions are observed:
a.
b.
c.
d.
e.
5.
To remove glass tubing or thermometers from rubber, preferably cut
a w a y the r u b b e r . T h i s is p a r t i c u l a r l y true if the t u b i n g or s t o p p e r has b e e n
in place over an extended period of time or has been subjected to heat.
6.
In handling beakers, support them by grasping around the sides, never
over the top. If one hand will not reach more than half way around the beaker,
use both hands. Support large beakers (one litre or more) from the bottom when
in use.
7.
W h e n h e a t i n g l i q u i d s in g l a s s by m e a n s of a gas f l a m e , p r o t e c t the
glass from direct contact with the flame by use of a wire gauze or a centered
wire gauze.
8.
W h e n p l a c i n g l i q u i d s in b o t t l e s w h i c h h a v e a p o s i t i v e c l o s u r e ,
reserve more than 5 percent of the volume as air space to allow for expansion
due to temperature changes.
9.
Do not force s t o p c o c k s or ground g l a s s s t o p p e r s .
Use a s t o p c o c k
puller.
If the n a t u r e of the c o n t e n t s of the v e s s e l p e r m i t s , cool the shell
until the plug is cold, then heat the shell of the joint momentarily.
Withdraw
the plug quickly before it too has been expanded by the heat.
Vacuus Operations
1.
Protect glassware under vacuum from physical
cracks and result in collapse with explosive violence.
2.
Do not subject flat-bottom flasks
heavy walls specifically for such service.
unless
to vacuum
cause
constructed
with
3.
Guard s t a n d a r d - w a l 1 ( s p h e r i c a l ) flasks larger than one l i t r e , w h e n
used in v a c u u m s e r v i c e , by a shield that is a d e q u a t e to stop all flying g l a s s
if collapse should occur.
4.
C h o o s e cork or r u b b e r s t o p p e r s used in v a c u u m s e r v i c e c a r e f u l l y .
They must be of such size that they will not be drawn through the opening which
they are intended to close.
5.
to disassemble
equipment.
6.
Do not s t o p p e r h o t flasks c o n t a i n i n g u n c o n d e n s e d v a p o u r s or
To do so will subject them to vacuum on cooling.
41
steam.
Equipment
Handling
1.
W h e n using a m a n u a l cork b o r e r , do not hold the s t o p p e r in the p a l m
of the hand.
Place the stopper large end down on a soft, flat surface and hold
in p l a c e w i t h the t h u m b and f o r e f i n g e r .
K e e p the b o r e r sharp and l u b r i c a t e
with water or glycerine to prevent binding. Do not force the borer through the
stopper but twist to cut the material.
Use stout gloves for added protection
in case of slippage.
2.
Do
not lift the cover of a c e n t r i f u g e until r o t a t i o n has
Keep the cover closed when the centrifuge is not in use.
stopped.
3.
C y l i n d e r s c o n t a i n i n g i n d u s t r i a l gases must be properly anchored by
chains or heavy straps or held in stands.
Reactive gases should be stored away
from each other (e.g. do not store a c e t y l e n e near oxygen).
Gas s u p p l i e s for
gas liquid chromatography and atomic absorption spectroscopy are best kept on
the other side of the wall from the instrument and connected via a small duct
in the w a l l .
C y l i n d e r s t o r a g e p o i n t s s h o u l d be p r o t e c t e d from the w e a t h e r ,
p a r t i c u l a r l y in dusty areas w h e r e grit can get into the c y l i n d e r v a l v e , but
they s h o u l d be s u f f i c i e n t l y w e l l - v e n t i l a t e d to p r e v e n t l e a k i n g gas f r o m
reaching dangerous levels.
4.
Flexible tubing attached to gas supplies must be wired on or held by
clips and must be able to withstand any likely pressure.
The sudden bursting
or b l o w i n g off of a piece of tubing is s t a r t l i n g and m a y c a u s e an a c c i d e n t if
someone nearby is carrying out a hazardous operation.
5.
A rapid decrease of cooling water due to a fall in mains pressure or
a cut in the supply can damage equipment such as a still and also be hazardous.
A c o n s t a n t head d e v i c e in a t r a n s p a r e n t c o n t a i n e r w i l l give s o m e w a r n i n g of
this. However, if water pressure fluctuations are a frequent problem, a header
tank in the roof of the building may be advisable. Electrical equipment can be
fitted with automatic cutouts that turn off the electricity supply in case of
water failure.
6.7
Equipment
emergency
Safety Equipment
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Rubber aprons.
Eye goggles.
Face shields..
Disposable plastic or rubber gloves.
Bench shields (portable, clear plastic).
Pipetting bulbs.
Heavy rubber carriers for acid and alkali bottles.
Metal safety cans for flammable solvents.
M e t a l solvent s t o r a g e c a b i n e t s (about 45 g a l l o n
storage of solvents used daily in the laboratory).
Respirator filter masks (for dust or fumes).
42
capacity).
(For
Emergency
1.
2.
3.
4.
5.
6.
Equipment
A major item of emergency equipment not included in the above list is the
aid cabinet.
This is discussed in detail in Section 6.8.
first
6.8
First
Aid
First aid by definition is that initial assistance given to lessen the effect
of injury.
If the injury is sufficiently minor, then first aid will probably
s u f f i c e for t r e a t m e n t .
H o w e v e r , for s e r i o u s and e v e n m o d e r a t e l y s e r i o u s
i n j u r i e s , m e d i c a l h e l p m u s t be g i v e n as soon as p o s s i b l e .
Any first aid
m e a s u r e s w o u l d be only to give t e m p o r a r y h e l p u n t i l m e d i c a l t r e a t m e n t is
available.
S o m e o n e on the l a b o r a t o r y s t a f f s h o u l d be t r a i n e d in f i r s t - a i d ,
particularly in giving artificial respiration techniques.
Some chemicals such
as c y a n i d e are q u i c k - a c t i n g and there is r a r e l y t i m e to w a i t for a d o c t o r to
arrive, or transfer the patient to the hospital.
T h o u g h t s h o u l d be g i v e n to the l o c a l h a z a r d s that m i g h t be e x p e c t e d and the
c o n t e n t s of a first aid c a b i n e t d e s i g n e d to m a t c h .
The c a b i n e t should be
l o c a t e d in the l a b o r a t o r y p r o p e r and be a c c e s s i b l e .
A first-aid cabinet
suitable for a laboratory of 10-50 employees could contain the following:
1.
2.
A s u f f i c i e n t n u m b e r (not l e s s
unmedicated dressings for injured fingers.
than
12)
treatment.
of
small
sterilized
3.
A s u f f i c i e n t n u m b e r (not less than 6 ) of m e d i u m - s i z e d
unmedicated dressings for injured hands or feet.
sterilized
4.
A sufficient number (not less than 6) of large sterilized
dressings for other injured parts.
unmedicated
5.
A sufficient number (not less than 24) of adhesive wound
an approved type and of assorted sizes.
6.
A s u f f i c i e n t n u m b e r (not less than 4 ) of
unbleached calico, the longest size of which measures
and each of the other sides not less than 36 inches.
7.
small
8.
A sufficient
packets.
supply
t r i a n g u l a r b a n d a g e s of
not less than 51 inches
plaster.
of a b s o r b e n t
43
dressings of
sterilized
cotton
in
individual
9.
approved
10. A sufficient n u m b e r
separate sealed packets.
(not
less
eye o i n t m e n t
than 4 ) of
11.
12.
Safety pins.
13.
A tube of antiseptic
in a container
sterilized
of an
eye-pads
in
cream.
A tablespoon.
Bottle of Epsom salts (magnesium sulphate).
Bottle of milk of magnesia (dose - two tablespoonfuls).
Bottle of 1 percent acetic acid.
Hydrogen cyanide, soluble cyanides and nitriles which hydrolyse readily to HCN
when inhaled or ingested may call for treatment with capsules (0.3 ml) of amyl
nitrite w h i c h are easily crushed in a cloth from w h i c h the vapour can be
inhaled.
The following antidote for cyanide ingestion casualties consists of
two solutions which should be made up and left ready for immediate use:
S o l u t i o n A:
158 g ferrous sulphate crystals and 3 g citric acid crystals
in a litre of cold distilled w a t e r (the solution m u s t be inspected regularly
and be replaced if any deterioration has occurred).
S o l u t i o n B:
distilled water.
60 g anhydrous
sodium
carbonate
dissolved
in a litre
of
44
used.
This is described in "First Aid" (2nd E d i t i o n 1965) published by St.
John A m b u l a n c e A s s o c i a t i o n , The St. A n d r e w A m b u l a n c e A s s o c i a t i o n and the
British Red Cross Society, as well as in standard medical texts.
Bromine, formic acid, hydrofluoric acid and other acid burns on the skin can be
treated with magnesia/glycerol paste prepared by triturating 200 g magnesium
oxide with 240 ml glycerol, the paste being applied liberally over the affected
areas. Dilute ammonia (1 volume ammonia added to 15 volumes of water) has also
been found e f f e c t i v e in reducing the degree of b u r n i n g w i t h b r o m i n e , formic
acid and hydrofluoric acid.
The laboratory should have at least one book (preferably more) on first aid and
laboratory safety.
There are m a n y such available.
Some of the better ones
are :
1.
2.
3.
4.
5.
6.
Medical
1973 .
Muir.
Company,
Institute
of
Fire
in the
Chemical
in Laboratories",
MRC, U.K.
7.
Aromatic
8.
Reference Book of P r o t e c t i v e
Association, London, 1981-82.
Research
Council, "Safety
Precautions
45
7.1
(QA)
Introduction
A laboratory engaged in food control analysis must have some means of assuring
that their analytical results are of the highest quality.
Errors in analysis
can o f t e n m e a n s e r i o u s e c o n o m i c l o s s e s for the food i n d u s t r y or i m p o r t e r , as
well as possible illness or injury to the consuming public.
This assurance of
quality is not limited to confirming that a food found to be unacceptable, is
in fact b a d .
It is e q u a l l y i m p o r t a n t to a s s u r e that f o o d s f o u n d to b e
a c c e p t a b l e , are in fact good.
To do this r e q u i r e s an u n d e r s t a n d i n g and
c o m m i t m e n t by the laboratory m a n a g e m e n t as well as the operating staff, that
high quality in analysis is the foremost objective.
O f t e n , the t e r m s " Q u a l i t y C o n t r o l " and " Q u a l i t y A s s u r a n c e " are used
interchangeably when discussing analytical quality.
H o w e v e r , G a r f i e l d (1)
m a k e s a d i s t i n c t i o n b e t w e e n the t w o .
He d e f i n e s Q u a l i t y c o n t r o l a s , "...a
p l a n n e d s y s t e m of a c t i v i t i e s w h o s e p u r p o s e is to p r o v i d e a q u a l i t y p r o d u c t . "
Conversely, he defines Quality Assurance as, "...a planned system of activities
w h o s e p u r p o s e is to p r o v i d e a s s u r a n c e that the q u a l i t y c o n t r o l p r o g r a m is
actually effective."
Therefore, Quality Control encompasses all of the myriad
r e v i e w , checking and operational procedures routinely used by the laboratory to
m a i n t a i n high analytical quality.
( M a n y of t h e s e are d i s c u s s e d in the
preceeding Chapters 4 and 5.) The following discussions of Quality Assurance
u s e s G a r f i e l d ' s d e f i n i t i o n and c o v e r s t h o s e p r o c e d u r e s u s e d to c o n f i r m t h a t
high quality is being maintained.
7.2
Establishing
a QA
Programme
The acceptable
quality
for a given
2.
3.
A system of documentation
4.
Appropriate
laboratory
function.
quality.
to record
reviews.
found.
The first step is to decide the functions that should have formal review.
Some
s u g g e s t i o n s a r e s t a n d a r d s s t o r a g e and h a n d l i n g , p r e p a r a t i o n of a n a l y s i s
r e p o r t s , i n s t r u m e n t m a i n t e n a n c e and l a b o r a t o r y s a f e t y .
T h e l a b o r a t o r y Head
should carefully examine the entire laboratory operation, by audit review if
n e c e s s a r y , and s e l e c t those f u n c t i o n s w h i c h need i m p r o v e m e n t or w h i c h w o u l d
benefit from periodic monitoring.
A QA p r o g r a m m e should be d y n a m i c and subject
to change when needed. Therefore a detailed QA review could be conducted until
it is felt that the function under review will continue to operate smoothly, at
w h i c h t i m e the r e v i e w could be l e s s e n e d and a n o t h e r f u n c t i o n g i v e n i n - d e p t h
coverage .
T h e r e v i e w i t s e l f is n o r m a l l y l i m i t e d to the c r i t i c a l p a r t s of the f u n c t i o n
under review.
For e x a m p l e , a r e v i e w of s t a n d a r d s t o r a g e and h a n d l i n g c o u l d
include: accounting for all standards by inventory and checking proper storage;
c h e c k i n g t h a t no s t a n d a r d h a s e x c e e d e d its e x p i r a t i o n or d i s p o s a l d a t e ; and
visual,
p h y s i c a l a n d / o r c h e m i c a l c h e c k s to i n d i c a t e
s t a n d a r d s are not
contaminated or decomposed.
46
1.
The laboratory shall operate an internal quality assurance p r o g r a m m e
a p p r o p r i a t e to the t y p e , r a n g e and v o l u m e of w o r k p e r f o r m e d .
The quality
assurance p r o g r a m m e shall be documented in a quality manual which is available
for u s e b y the l a b o r a t o r y s t a f f .
T h e q u a l i t y m a n u a l s h a l l be m a i n t a i n e d
relevant and current by a responsible m e m b e r of the laboratory staff. A person
or persons having responsibility for q u a l i t y a s s u r a n c e w i t h i n the l a b o r a t o r y
shall be designated by the laboratory m a n a g e m e n t and have direct access to top
management.
2.
shall contain
information
regarding:
a.
(organizational
charts);
b.
c.
d.
Quality assurance
appropriate ;
e.
Where
appropriate,
m a t e r i a l , etc.;
f.
S a t i s f a c t o r y a r r a n g e m e n t s for f e e d b a c k and c o r r e c t i v e
whenever testing discrepancies are detected;
g.
Procedure
procedures;
procedures
proficiency
specific
testing,
for
use
each
of
test,
as
reference
action
complaints.
3.
The quality system shall be systematically and periodically reviewed
by or on b e h a l f of m a n a g e m e n t to e n s u r e the c o n t i n u e d e f f e c t i v e n e s s of the
arrangements, and corrective action initiated.
Such reviews shall be recorded
together with details of any corrective action taken.
47
DEFINITIONS
Quality Manual
Quality System
Terminology
Testing Laboratory
Test Method
Test Report
ENVIRONMENT
External
Internal
Controls
Controls
E Q U I P M E N T , TESTING AND
MEASURING
Calibration
Identification
Inter laboratory Correlation
P r i o r to U s e
Programmes
U s e of I n - S e r v i c e T e s t E q u i p m e n t
U s e of R e f e r e n c e S t a n d a r d s
External
In-house
O v e r l o a d e d or M i s h a n d l e d
Periodic Maintenance
P u r c h a s i n g and A c c e p t a n c e P r o c e d u r e s
Records
LABORATORY DESCRIPTION
Confidential Information
Employee Responsibility
F i e l d s of A c t i v i t y
Identification
Minimizing Improper Influence
Organizational Structure
Proprietary Rights
Technical Management Personnel
QUALITY MANAGEMENT SYSTEM
Corrective Action
F i e l d s of T e s t i n g A c t i v i t i e s
Obj ec t i v e
P r o f i c i e n c y and I n t e r l a b o r a t o r y C o m p a r i s o n T e s t i n g
Quality Assurance Management
Q u a l i t y M a n u a l - R e v i s i o n and D i s t r i b u t i o n
Quality Policy
Quality System Audit
R e s p o n s i b i l i t y for Q u a l i t y A s s u r a n c e S y s t e m
Reference Materials
Resources Employed
Scope
S u b c o n t r a c ting
Technical Complaints
U p d a t i n g and C o n t r o l of D o c u m e n t s
U s e of E x t e r n a l F a c i l i t i e s
RECORDS
C o n f i d e n t i a l i t y and S e c u r i t y
H i s t o r i c a l F i l e of T e s t M e t h o d s
Maintenance
48
SAMPLES/ITEMS TO BE TESTED
P r o t e c t i o n from Damage
R e c e i p t and D i s p o s a l
Security
STAFF
Deputy Assignments
Job D e s c r i p t i o n s
P e r s o n n e l Records
S u p e r v i s ion
Other Measures
TEST METHODS AND PROCEDURES
I n d e x of Documents
S e l e c t i o n of Test Methods
Use of Non-Standard Test Methods
TEST REPORTS/TEST
Computerized
Format
Revision
Verification
DOCUMENTS
Date
of
Dsta
T h e a b o v e i l l u s t r a t e s h o w c o m p l e x and t h o r o u g h the d o c u m e n t a t i o n f o r a QA
programme can b e .
O b v i o u s l y , not a l l l a b o r a t o r i e s w i l l need such c o m p l e t e n e s s .
H o w e v e r , t h e r e i s a m i n i m u m QA p r o g r a m m e w h i c h s h o u l d be d o n e e v e n in the
s m a l l e s t of food c o n t r o l l a b o r a t o r i e s .
T h i s should i n c l u d e the four key a r e a s
where q u a l i t y c h e c k i n g is needed most.
These are r e f e r e n c e standard m a t e r i a l
used in a n a l y s i s ,
laboratory measuring instruments,
a n a l y s i s r e p o r t s and the
t e c h n i c a l p r o f i c i e n c y of the a n a l y t i c a l s t a f f .
The l a t t e r can be r e v i e w e d in
p a r t by use of a c h e c k s a m p l e a n a l y s i s p r o g r a m m e .
T h e s e f o u r QA c h e c k a r e a s
a r e d i s c u s s e d in d e t a i l in s u c c e e d i n g S e c t i o n s 7 . 3 to 7 . 6 .
O t h e r r e l a t e d QA
a c t i v i t i e s are d i s c u s s e d under S e c t i o n 7 . 7 .
7.3
QA of R e f e r e n c e
Standards
F o r p u r p o s e s of t h i s S e c t i o n , a " R e f e r e n c e S t a n d a r d " i s a p u r e c h e m i c a l or
b i o l o g i c a l s u b s t a n c e w h i c h may be used for c o m p a r i s o n d u r i n g the q u a n t i t a t i v e
a n d / o r q u a l i t a t i v e a n a l y s i s of a c o n s t i t u e n t or a t t r i b u t e of a f o o d .
Of
c o u r s e , " p u r e " is a r e l a t i v e term.
Some m e t a l e l e m e n t s c a n be r o u t i n e l y
o b t a i n e d in 9 9 . 9 9 9 % p u r i t y , w h i l e many o r g a n i c s u b s t a n c e s would be c o n s i d e r e d
" p u r e " at 9 5 % .
The a n a l y s t m u s t j u d g e i f t h e r e f e r e n c e s t a n d a r d u s e d i s
s u f f i c i e n t l y pure for a n a l y s i s p u r p o s e s .
R e f e r e n c e s t a n d a r d s can be d i v i d e d
i n t o three g r o u p s :
1.
Primary:
These are m a t e r i a l s which have been a n a l y z e d and
c e r t i f i e d by a n a t i o n a l s t a n d a r d s o r g a n i z a t i o n or o t h e r a c c e p t a b l e
organization.
2.
Secondary:
S u b s t a n c e s whose p u r i t y is
commercial s u p p l i e r s or o r g a n i z a t i o n s o t h e r than the
certified
above.
by
the p u r i t y
certifying
analysis
by
3.
Other:
This i n c l u d e s a l l r e f e r e n c e s t a n d a r d s w h i c h are c o n s i d e r e d
a c c e p t a b l e by t h e u s e r , b u t w h i c h do n o t f a l l i n t h e a b o v e t w o g r o u p i n g s .
T h e s e can i n c l u d e l o c a l l y o b t a i n e d m a t e r i a l s w h i c h h a v e u n d e r g o n e r e p l i c a t e
a n a l y s i s and have been compared to p r i m a r y or s e c o n d a r y r e f e r e n c e s t a n d a r d s , to
calculate purity.
49
Reference
Standards
for p r i m a r y
Source
Number
Alcohols
21
Alkenes
21
Antibiotics
(Chlortetracycline
HC1)
(Erythromycin)
15
(Monensin
14
Sodium)
(Oxytetracycline
(Penicillin
Base)
"G" P r o c a i n e )
(Streptomycin
Sulfate)
(Tylosin)
Atomic
Absorption
Bacterial
Blood
(Metals)
Reference
12
11
12
14
22
Cultures
1, 2 , 3, 4
Group/Typing
Chemicals, Industrial
1 9 , 3 2 , 38
13
1 0 , 34
(Animal)
1 8 , 2 5 , 31
(U.S. Schedules
I, II)
1 6 , 1 7 , 18
(U.S. Schedules
18
Ethanol, Absolute
37
Fibers, Synthetic
21
Fuels, Motor
35
Lead
(Alcoholic Beverages)
34
(Blood)
20
(Motor Fuels)
22
50
or
Reference
Standards
Source
Htmber
23, 30, 36
23
(Sludge)
34
17,
Mycotoxins
Pesticides
Phenylalanine (PKU)
3, 4
1, 3
1, 5
27, 28
(Known Meats)
29
36
Streptococcus
19
Trichinosis
Tuleremia
1, 6, 7
Wine (Reference)
23
2.
3.
Difco Laboratories
P.O. Box 1058
Detroit, MI 48232
4.
5.
Fisher Scientific
7633 Hull Street Road
Suite 2000D
Richmond, VA 23235
6.
M A Bioproducts
Briggs Ford Road
Building 100
Walkersville, MD 21793
51
7.
8.
Wellcome Diagnostics
Research Triangle Park
North Carolina 27709
9.
American Dade
P.O. Box 520672
Miami, FL 33152
10
11
12
Pfizer Laboratories
235 E. 42nd Street
New York, NY 10017
13
Lederle Laboratories
Division of American Cyanamid
One Cyanamid Plaza
Wayne, NJ 07470
14
15
16
17
Applied Science
P.O. Box 440
State College, PA 16801
18
19
20,
E. S. A. Inc.
45 Wiggins Avenue
Bedford, MA 01730
21,
Supelco Inc.
Supelco Park
Bellefonte , PA 16823
22,
Division
52
(US-DEA)
23.
24.
25.
26.
Eureka
215 - 26th Street
Sacramento, CA 95816
27.
Admin.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
53
Services
(MD-8)
38.
Chem Service
P.O. Box 194
West Chester, PA
19380
Once a stock of appropriate reference standards has been obtained, they must be
recorded, used and stored properly.
A records book or file cards can be used,
with the following information noted for each standard:
1.
2.
Source
3.
4.
Purity.
5.
Expiration date
(if any).
6.
Special
storage
requirements.
7.
Storage
location.
(from where
received.
obtained).
for?
the
Quality
Assurance
checking
2.
Storage
(is
If not, w h y ? )
3.
review?
place,
the
storage proper?
standards
Physical Condition
( W h e r e w a s the s t a n d a r d at the
Any physical evidence of deterioration or m i s h a n d l i n g ? )
accounted
time
of
the
The t i m i n g of the r e v i e w w o u l d d e p e n d on n e e d .
An i n i t i a l c y c l e of t h r e e
m o n t h s is s u g g e s t e d .
T h i s c a n b e i n c r e a s e d or d e c r e a s e d as c o n d i t i o n s and
review results dictate.
54
7.4
QA of
Instruments
Analytical
1.
and
schedule
for
some
general
Balances
Sensitivity
(bimonthly)
2.
Calibration
(annual)
with
annual
55
cleaning
and
maintenance,
again
Spectrophotometers
1.
(ultraviolet and
Wavelength
Accuracy
visible)
(bimonthly)
2.
Photometric
Accuracy
(bimonthly)
P r e p a r e a s o l u t i o n of 60 _+ 0.25 m g p o t a s s i u m d i c h r o m a t e in o n e l i t r e
of 0.01N s u l p h u r i c a c i d .
( T h i s s o l u t i o n is q u i t e s t a b l e a n d o n c e
p r e p a r e d can be used a long time).
S c a n this s o l u t i o n f r o m 2 1 0 to
450 n m .
T h e f o l l o w i n g a b s o r b a n c e s (+ 1% f u l l s c a l e ) s h o u l d o c c u r at
the i n d i c a t e d w a v e l e n g t h s :
Wavelength
(nm)
Absorbance
235
257
313
350
0.747
0.869
0.293
0.644
A l t e r n a t i v e l y , t h e U.S. N a t i o n a l B u r e a u of S t a n d a r d s h a s a v a i l a b l e
for p u r c h a s e S R M 9 3 0 , a g l a s s f i l t e r w h i c h c a n b e u s e d s i m i l a r l y and
which has certified wavelength/absorbance values.
Spectrophotometer
1.
(infrared)
Wavelength Accuracy
(trimonthly)
Wavenumber
(cm
1.
Baseline
(atomic
+
_+
+
+
absorption)
(daily when
Absorbance
the
6
6
2
2
used)
U s i n g f l a m e o n l y , the r e c o r d e r b a s e l i n e s h o u l d
.005 a b s o r b a n c e u n i t s in a f i v e m i n u t e p e r i o d .
2.
at
Accuracy
2851
1601
1028
907
Spectrophotometer
occur
(daily when
not vary m o r e
than +
used)
T h r e e c o n s e c u t i v e a b s o r b a n c e c h e c k s of the
v a r y m o r e t h a n _+ .005 a b s o r b a n c e u n i t s .
56
same
solution
should
not
3.
Detection Limit
(monthly)
Gas
Chromatograph
1.
Column Oven
(semiannual)
2.
pyrometer.
(monthly)
C h e c k f l o w rates of all c a r r i e r
bubble meter or other device.
3.
a calibrated
Detector Response
(daily when
and
detector
gases
u s e d , using
used)
Compare present detector response with the response obtained when new
or w h e n last c l e a n e d and c a l i b r a t e d .
(in s o m e d e t e c t o r s , n o t a b l y
e l e c t r o n c a p t u r e , a d e t e r i o r a t i n g r e s p o n s e i n d i c a t e s a need for
cleaning).
1.
Chrcmatograph
used)
2.
57
7.5
QA of Analytical
Reports
1.
The work carried out by the testing laboratory shall be covered by a
report w h i c h accurately, clearly and u n a m b i g u o u s l y p r e s e n t s the t e s t r e s u l t s
and all other relevant information.
2.
shall
include at least
the following
information:
a.
b.
Unique identification of
each page of the report.
c.
d.
e.
D a t e of r e c e i p t of test
tests, as appropriate.
f.
g.
Identification
h.
Description of sampling
i.
Any d e v i a t i o n s ,
additions
specification, and any other
test .
j.
Disclosure
ut ilized.
k.
M e a s u r e m e n t s , e x a m i n a t i o n s and d e r i v e d r e s u l t s , s u p p o r t e d by
t a b l e s , g r a p h s , s k e t c h e s , p h o t o g r a p h s as a p p r o p r i a t e , and any
failure identified.
1.
A statement on measurement
m.
A s i g n a t u r e a n d t i t l e of p e r s o n ( s ) a c c e p t i n g
technical
responsibility for the test report and date of issue.
n.
A s t a t e m e n t that t h e r e p o r t s h a l l n o t be r e p r o d u c e d
full without the approval of the testing laboratory.
of
report
(such
as serial
number),
and
of
performance
of
client.
of the test
any
company.
item
and
date(s)
of
specification, method
procedure, where
and
procedure.
relevant.
non-standard
58
item.
test
uncertainty
method
(where
or
procedure
relevant).
except
in
3.
Particular care and attention shall be paid to the arrangement of the
test report, especially with regard to presentation of the test data and ease
of assimilation by the reader.
The format shall be carefully and specifically
a s s i g n e d for e a c h type of test c a r r i e d o u t , but the h e a d i n g s shall be
standardized as far as possible.
The U.S. Food and Drug A d m i n i s t r a t i o n " A n a l y s t W o r k s h e e t "
good example for purposes of discussing an analytical report
is relatively complete and includes space for all pertinent
analytical summary.
The r e v e r s e of the form w o u l d be used
and calculations as the analysis progresses.
(Figure 7.1) is a
QA programme.
It
data including an
for r a w w o r k d a t a
An a n a l y t i c a l r e p o r t QA p r o g r a m m e should i n v o l v e r e v i e w of a p r e d e t e r m i n e d
n u m b e r of c o m p l e t e d r e p o r t s on a m o n t h l y or b i m o n t h l y b a s i s .
The r e p o r t s
should be r e p r e s e n t a t i v e of the k i n d s of w o r k d o n e , w i t h a b o u t as m a n y w h i c h
s h o w law v i o l a t i o n s as are u s u a l l y e n c o u n t e r e d .
An e x a m p l e could be ten
r e p o r t s w i t h t w o b e i n g v i o l a t i v e ( a s s u m i n g the v i o l a t i o n rate is about 20%).
The object is to gain a relatively representative sampling of completed reports
in order to evaluate overall report writing.
If some section of the laboratory
has substandard reports, then their coverage can be selectively increased until
it a p p e a r s that the r e p o r t s are s a t i s f a c t o r y .
T h i s is one of the p r i m e
f u n c t i o n s of QA r e v i e w s ( w h a t e v e r the t y p e ) - to p i n p o i n t p r o b l e m areas and
give them visibility until the problem is solved.
An example of an analytical report review protocol is one which has been used
by the U.S. Food and Drug A d m i n i s t r a t i o n for QA r e v i e w of their A n a l y t i c a l
Worksheets.
Their protocol consists of a listing of performance factors that
their Worksheet (Figure 7.1) must meet, as follows:
1.
2.
Accuracy and
Completeness
a.
b.
c.
Information on the
Collection Report.
d.
T h e u s e of a p p r o p r i a t e
equipment is described.
e.
f.
If m o r e than one p e r s o n p a r t i c i p a t e d in
worksheet clearly indicates who did what.
g.
h.
i.
Any discarded
Analytical
worksheet
results are
the
sample
and
is compatible
standards,
condition
with
reagents,
the
the
and
when
integrity
Inspection
special
analysis,
the
reported.
entry
and
explained.
Methodology
The a p p r o p r i a t e m e t h o d
is used and is r e f e r e n c e d on the
worksheet.
Analyses performed and methods used are consistent
with appropriate instructions or as directed by the Supervisor.
59
ANALYST WORKSHEET
3. S E A L S
NONE
INTACT
BROKEN
1. P R O D U C T
4. D A T E
REC'D
2. S A M P L E
5. R E C E I V E D
FROM
NUMBER
6. D I S T R I C T O R L A B O R A T O R Y
7. D E S C R I P T I O N O F S A M P L E
8.
NET
CONTENTS
NOT APPLICABLE
DECLARE/UNIT
NOT DETERMINED
AMOUNT
UNITS E X A M I N E D
% OF
10. S U M M A R Y O F
11. R E S E R V E
.ORIGINAL(S)
LABELING
FOUND.
DECLARED
.COPIES
SUBMITTED
SUBMITTED
NONE
ANALYSIS
SAMPLE
1 2 . L. A N A L Y S T S I G N A T U R E (Broke
Seal
)
WORKSHEET
CHECK
14. D A T E
P R E V I O U S E D I T I O N IS O B S O L E T E .
Figure
USFDA
Analyst
60
7.1
Worksheet
REPORTED
PAGE
OF
PAGES
3.
4.
b.
Sample is analyzed so
laws or regulations.
c.
Deviations
worksheet.
d.
Supervisory
from
the
as
to
permit
referenced
used
application
method
are
of
appriopriate
explained
on
the
is validated.
Review
a.
The a n a l y s i s and m e t h o d o l o g y w a s a p p r o p r i a t e
indicated on the inspection collection report.
b.
L a b o r a t o r y c o n c l u s i o n s and final d e c i s i o n
supported by information on the worksheet.
c.
Time
Frames
a.
Sample analysis
violative,
to
are
the
problem
accurate
a confirming
analysis
and
is
Any deviations from the above which are found during the r e v i e w , are recorded
and an a t t e m p t m a d e to d e t e r m i n e h o w they o c c u r r e d .
T h e r e v i e w e r m a y find a
p a t t e r n s u c h as c e r t a i n e r r o r s a r e c o n s i s t e n t l y m a d e , i n d i c a t i n g a n e e d for
specific training.
A l l f o l l o w - u p a c t i v i t i e s and a c t i o n s t a k e n to c o r r e c t
p r o b l e m s , m u s t be detailed and documented to provide laboratory m a n a g e m e n t with
a continuing basis to evaluate improvement.
7.6
Check Sampl
Examination
O n e of the m o s t c o m m o n w a y s to e v a l u a t e o v e r a l l i n d i v i d u a l or l a b o r a t o r y
p e r f o r m a n c e in a g i v e n a n a l y s i s , is b y u s e of k n o w n c h e c k s a m p l e s .
This
i n c l u d e s b o t h i n t r a ( w i t h i n ) the l a b o r a t o r y and i n t e r ( b e t w e e n ) like
laboratories.
The A m e r i c a n Chemical Society (ACS) in their 1980 Guidelines for
Data Quality Evaluation, stated:
"At the o u t s e t , a l a b o r a t o r y s h o u l d d e m o n s t r a t e its p r o f i c i e n c y u s i n g
prototype and non-critical samples, thereby reducing the probability that bad
d a t a w i l l be g e n e r a t e d on c r i t i c a l s a m p l e s , e s p e c i a l l y t h o s e i n v o l v i n g
complicated unknown mixtures.
An i n t r a l a b o r a t o r y q u a l i t y c o n t r o l p r o g r a m
s h o u l d i n c l u d e the use of b l i n d s a m p l e s in a d d i t i o n to c h e c k s a m p l e s w h o s e
v a l u e s are k n o w n to the a n a l y s t s .
A l l a n a l y s t s s h o u l d be m o n i t o r e d b y the
quality control procedures, and any assessment of laboratory performance should
include all of the analysts involved, or at least a random selection of those
analysts.
I n t e r l a b o r a t o r y Q u a l i t y A s s u r a n c e p r o g r a m s s h o u l d also use b l i n d
s a m p l e s in a d d i t i o n to c h e c k s a m p l e s ,
in o r d e r to p r o v i d e a r e a l i s t i c
assessment of the performance of the method that is achievable in the field."
L a t e r , in 1 9 8 2 , the A C S m a d e an a d d i t i o n a l s t a t e m e n t
reliability and acceptability of analysis data:
regarding
improving
61
factors
influencing
final
DATA
Figure 7.2
During 1984, the U.S. Association of Food and Drug Officials (AFDO) assembled a
listing of proficiency and check sample programs available through various U.S.
a g e n c i e s and o r g a n i z a t i o n s .
The listing is as f o l l o w s , giving c h e c k s a m p l e
type, the product involved and the check sample program sponsor:
Program
Sponsor
Product(s)
Aflatoxins
Milk, Corn
Alcohol
Blood
Antibiotics
Meat
Antibiotics
Milk
Arsenic
Meat, Poultry
Filters
Asbestos
(Number of Fibres)
Bacteriology
Milk, General
Bioassay of Antibiotics
Feed s
Cations
Water
Cereal
Water
Cereal
Components
Coliforms
62
Food
6,7
Drinking Water,
Fatty
Prograai
Sponsor
Product(s)
Water
Fats and
Acids
Oils
Fertilizers
Frtilizers
13
Fibre
Fibre
11
Flammables
Various
11
Fluoride
Water
Food
Various
Characterization
Components
Herbicides and
Industrial
Lead and
Chemicals
FEP
Medicated
Metals
Organics
Feeds
(Cations)
Metals and
Foods
Urine and
17
Water
10
Fish
Blood
Feed s
Food
Water
Minerals
Microb iology
Microscopic
14
Various
Characterization
Products
18,19
Feed s
15
Mould s
Mycology
Organic
Chemicals
Water
Organic
Solvents
Charcoal
Organics
Semi-Volatile
Organochlorine
Tube
Synthetic
Compounds
14
Organics
Leachate
12
Plasma
10
Fat, Blood
Meats,
Poultry
Phosphatase
Milk
Protein/Moisture/Fat/Salt
Meat
Residues,
Meats,
Pesticide
Poultry
Pesticides/Herbicides
Water
Pesticides/Herbicides
Vegetables,
Smalley Oil
Feed s
Milk
Somatic
Cell
Meals
Count
and Drinking
Sulfonamide s
Meats,
Vitamins
Milk, Feed,
Waste Water
Parameters
Water
63
Foods
Poultry
Foods
Water
9,10,14
6,16
4
1
9
The U . S . s p o n s o r s
1.
A m e r i c a n A s s o c i a t i o n of C e r e a l
3340 P i l o t K n o b Road
St. P a u l , MN 55121
2.
A m e r i c a n Oil C h e m i s t s Society
508 South Sixth Street
C h a m p a i g n , IL 61820
3.
U . S . D e p a r t m e n t of T r a n s p o r t a t i o n
Transportation Systems Center, Kendall
Cambridge, MA 02142
are
Chemists
Square
4.
U . S . D e p a r t m e n t of A g r i c u l t u r e , FSIS
P . O . Box 5080
S t . L o u i s , MO 63115
5.
N a t i o n a l I n s t i t u t e of O c c u p a t i o n a l Safety and H e a l t h
C h e m i c a l R e f e r e n c e L a b o r a t o r y (PAT) (R-3)
4676 C o l o m b i a P a r k w a y
C i n c i n n a t i , OH 4 5 2 2 6
6.
U . S . Food and D r u g A d m i n i s t r a t i o n
1090 T u s c u l u m A v e n u e
C i n c i n n a t i , OH 4 5 2 2 6
7.
U . S . C e n t e r for D i s e a s e C o n t r o l
Chief, Performance Evaluation Branch, Laboratory
P r o g r a m O f f i c e , A t l a n t a , GA 3 0 3 3 3
Telephone: (404) 329-3847
8.
A m e r i c a n A s s o c i a t i o n of Feed C o n t r o l
c/o L a w and C o m p a n y
P . O . B o x 1558
A t l a n t a , GA 30301
9.
U . S . Environmental Protection
QA B r a n c h , EMSL
C i n c i n n a t i , OH 4 5 2 6 8
10.
U . S . E n v i r o n m e n t a l P r o t e c t i o n A g e n c y , QA D i v i s i o n
E M S L , P . O . Box 15027
Las V e g a s , NV 89114
T e l e p h o n e : (702) 7 9 8 - 2 1 0 0
11.
12.
A m e r i c a n S o c i e t y for Testing
1916 R a c e S t r e e t
P h i l a d e l p h i a , PA 19103
13.
A s s o c i a t i o n of A m e r i c a n Plant Food C o n t r o l O f f i c i a l s
c/o W . Penn Z e n t m e y e r
V A D e p a r t m e n t of A g r i c u l t u r e and C o n s u m e r S e r v i c e s
P . O . Box 1163
R i c h m o n d , VA 23201
Telephone: (804) 786-3511
Officials
Agency
Material
64
14.
15.
16.
17.
18.
19.
Microscopists
It is a d v i s a b l e to p a r t i c i p a t e in as m a n y i n t e r - 1 a b o r a t o r y c h e c k s a m p l e
p r o g r a m s as are a v a i l a b l e in the a r e a s of i n t e r e s t to the l a b o r a t o r y .
The
s p o n s o r i n g o r g a n i z a t i o n s u s u a l l y p r o v i d e a s u m m a r y r e p o r t to p a r t i c p a t i n g
l a b o r a t o r i e s , w h i c h g i v e s an e v a l u a t i o n of the l a b o r a t o r y ' s p e r f o r m a n c e as
compared
to o t h e r p a r t i c i p a n t s .
T h e i n t e r - 1 a b o r a t o r y p r o g r a m can be
supplemented by an intra program to highlight specific areas of concern which
W h e n s e l e c t i n g s a m p l e s for an
are n o t c o v e r e d in the inter p a r t i c i p a t i o n .
intra program, the following considerations should be taken into account:
1.
The capability
laboratory.
to analyze
the
2.
3.
4.
is generally
in the
employed.
techniques,
including
in cost.
A l w a y s keep in mind that the evaluation of check sample results must include
all aspects of the analysis.
In cases where there is a large discrepancy from
the expected or true result, the laboratory must investigate all aspects of the
analysis (as given in Figure 7.2) to d e t e r m i n e w h a t specific analysis area or
areas are suspect.
From this, the laboratory should take appropriate action to
prevent reoccurrence of a similar difficulty.
65
7.7
Other QA Activities
1.
S a f e t y - The laboratory safety programme can be periodically reviewed
(about every three months) to determine that safety and emergency materials are
on hand and b e i n g used. T h i s w o u l d i n c l u d e a c h e c k of any i n j u r y or a c c i d e n t
records and a review that appropriate follow-up corrective measures were taken.
2.
S u p p l y M a n a g e m e n t - R e f e r e n c e s t a n d a r d h a n d l i n g and s t o r a g e w a s
discussed earlier.
The s a m e g e n e r a l p r i n c i p l e s a p p l y to all l a b o r a t o r y
supplies, such as glassware, chemicals, solvents and others. A QA review would
focus on whether supplies are being ordered, stored and distributed properly.
3.
S a m p l e M a n a g e m e n t - The s a m p l e s r e c e i v e d by the l a b o r a t o r y for
analysis must be accounted for. This is even more critical when the laboratory
is i n v o l v e d in food l a w e n f o r c e m e n t .
An a c c o u n t a b i l i t y s y s t e m s h o u l d be
e s t a b l i s h e d and in o p e r a t i o n (see S e c t i o n s 4.2 and 4.3). The QA r e v i e w w o u l d
determine that the system is working properly and that samples are accounted
for throughout their receipt, storage, analysis and final disposition.
4.
T r a i n i n g - This m a y s e e m an odd area for QA r e v i e w , but it r a n k s in
importance to most other laboratory operations.
A QA review of training could
i n c l u d e c h e c k s of o n g o i n g f o r m a l t r a i n i n g p r o g r a m m e s for n e w a n a l y s t s and
checks of training needs and records for experienced analysts.
The importance
of t r a i n i n g c a n n o t be o v e r e m p h a s i z e d and a QA r e v i e w p r o g r a m m e o f t e n g i v e s
training needed visibility to management.
The above are only examples and laboratory management must select with care the
o p e r a t i o n a l areas n e e d e d for Q u a l i t y A s s u r a n c e r e v i e w .
R e m e m b e r that any
laboratory function can be (and often should be) subject to QA review.
7.8
Text
1.
G A R F I E L D , F.M.,
Laboratories, 2.
VA, U.S.A.
2.
3.
INTERNATIONAL LABORATORY
Report of Task Force D.
Farther
References
1985.
Q u a l i t y A s s u r a n c e P r i n c i p l e s for A n a l y t i c a l
Association of Official Analytical Chemists, Arlington,
ACCREDATION
CONFERENCE,
London.
Oct.
of
1984.
Reading
E v a l u a t i o n and
of
Standards,
66
of
D U N C A N , A.J.
1974.
Q u a l i t y C o n t r o l and I n d u s t r i a l
Richard D. Irwin, Inc., Homewood, IL., U.S.A.
Statistics,
4th
Ed.,
GRYNA,
1980.
Quality
F.M. & B I N G H A M ,
Planning
B.S.
1974.
and Analysis,
Quality
Laboratories,
McGraw-Hill.
Control
Handbook,
67
the
AOAC,
F A O T E C H N I C A L PAPERS
F A O F O O D A N D N U T R I T I O N PAPERS
1/1
1/2
Report of t h e joint F A O / W H O / U N E P c o n f e r e n c e o n
m y c o t o x i n s , 1 9 7 7 (E F S)
Report o f a j o i n t F A O / W H O expert c o n s u l t a t i o n o n
dietary f a t s and oils in h u m a n nutrition,
18 Rev. 1
Bibliography of f o o d c o n s u m p t i o n s u r v e y s ,
1 9 8 4 (E)
18 Rev. 2
Bibliography of f o o d c o n s u m p t i o n s u r v e y s ,
1 9 8 7 (E)
18 Rev. 3
Bibliography of f o o d c o n s u m p t i o n s u r v e y s ,
1 9 9 0 (E)
19
20
21
22
Legumes in h u m a n n u t r i t i o n , 1 9 8 2 (E F S)
M y c o t o x i n surveillance - a guideline, 1 9 8 2 (E)
Guidelines for agricultural t r a i n i n g curricula in
A f r i c a , 1 9 8 2 (E F)
23
M a n a g e m e n t of g r o u p f e e d i n g p r o g r a m m e s ,
1 9 8 2 (E F P S)
Food and n u t r i t i o n in t h e m a n a g e m e n t of g r o u p
feeding p r o g r a m m e s , 1 9 9 3 (E F S)
Evaluation o f n u t r i t i o n i n t e r v e n t i o n s , 1 9 8 2 (E)
JECFA s p e c i f i c a t i o n s for i d e n t i t y and p u r i t y of
b u f f e r i n g agents, salts; e m u l s i f i e r s , t h i c k e n i n g
a g e n t s , stabilizers; f l a v o u r i n g a g e n t s , f o o d
colours, s w e e t e n i n g agents and m i s c e l l a n e o u s
f o o d additives, 1 9 8 2 (E F)
Food c o m p o s i t i o n tables for t h e Near East,
1 9 7 7 (E F S)
1 9 7 8 (E)
5
5 Rev. 1
5 Rev. 2
JECFA - guide t o s p e c i f i c a t i o n s , 1 9 7 8 (E F)
JECFA - guide t o s p e c i f i c a t i o n s , 1 9 8 3 (E F)
JECFA - guide t o s p e c i f i c a t i o n s , 1 9 9 1 (E)
W o m e n in f o o d p r o d u c t i o n , f o o d handling and
n u t r i t i o n , 1 9 7 9 (E F S)
A r s e n i c and t i n in f o o d s : r e v i e w s of c o m m o n l y
u s e d m e t h o d s of analysis, 1 9 7 9 (E)
10
11
12
P r e v e n t i o n of m y c o t o x i n s , 1 9 7 9 (E F S)
The e c o n o m i c value of breast-feeding, 1 9 7 9 (E F)
JECFA s p e c i f i c a t i o n s for i d e n t i t y and purity of
f o o d c o l o u r s , f l a v o u r i n g agents and other f o o d
a d d i t i v e s , 1 9 7 9 (E F)
2 3 Rev. 1
24
25
26
27
28
1 9 8 3 (E)
Review of f o o d c o n s u m p t i o n s u r v e y s 1 9 8 1 ,
1 9 8 3 (E)
JECFA s p e c i f i c a t i o n s for i d e n t i t y and p u r i t y of
b u f f e r i n g agents, salts, e m u l s i f i e r s , stabilizers,
t h i c k e n i n g agents, e x t r a c t i o n s o l v e n t s , f l a v o u r i n g
agents, s w e e t e n i n g agents and m i s c e l l a n e o u s
f o o d additives, 1 9 8 3 (E F)
Post-harvest losses in quality of f o o d grains,
1 9 8 3 (E F)
13
Perspective o n m y c o t o x i n s , 1 9 7 9 (E F S)
14
14/1
1 4 / 1 Rev.1
14/2
A d d i t i v e s , c o n t a m i n a n t s , t e c h n i q u e s , 1 9 8 0 (E)
14/3
14/4
C o m m o d i t i e s , 1 9 7 9 (E)
M i c r o b i o l o g i c a l analysis, 1 9 7 9 (E F S)
30
F A O / W H O f o o d additives d a t a s y s t e m , 1 9 8 4 (E)
3 0 Rev. 1
14/5
14/6
1 4 / 6 Rev.1
14/7
Food
Food
Food
Food
31/1
c o n t a m i n a n t s and c o m p o s i t i o n , 1 9 8 6 (C E)
Food analysis: q u a l i t y , adulteration and t e s t s of
32
14/8
i d e n t i t y , 1 9 8 6 (E)
I n t r o d u c t i o n t o f o o d s a m p l i n g , 1 9 8 8 (Ar C E F S)
T r a i n i n g in m y c o t o x i n s analysis, 1 9 9 0 (E S)
M a n a g e m e n t of f o o d c o n t r o l p r o g r a m m e s ,
33
14/9
14/10
14/11
1 9 9 1 (E)
Q u a l i t y a s s u r a n c e in the f o o d c o n t r o l
m i c r o b i o l o g i c a l laboratory, 1 9 9 2 (E F S)
Pesticide residue analysis in t h e f o o d c o n t r o l
l a b o r a t o r y , 1 9 9 3 (E F)
Q u a l i t y assurance in t h e f o o d c o n t r o l chemical
35
R e v i e w of f o o d c o n s u m p t i o n s u r v e y s 1 9 8 5 ,
1 9 8 6 (E)
36
l a b o r a t o r y , 1 9 9 3 (E)
I m p o r t e d f o o d inspection, 1 9 9 3 (E F)
Radionuclides in f o o d , 1 9 9 4 (E)
C a r b o h y d r a t e s in h u m a n nutrition, 1 9 8 0 (E F S)
A n a l y s i s of f o o d c o n s u m p t i o n s u r v e y data for
d e v e l o p i n g c o u n t r i e s , 1 9 8 0 (E F S)
JECFA s p e c i f i c a t i o n s for i d e n t i t y and p u r i t y of
s w e e t e n i n g a g e n t s , e m u l s i f y i n g agents, f l a v o u r i n g
a g e n t s and other f o o d additives, 1 9 8 0 (E F)
Bibliography of f o o d c o n s u m p t i o n s u r v e y s ,
1 9 8 1 (E)
38
39
Quality c o n t r o l in f r u i t and v e g e t a b l e p r o c e s s i n g ,
1 9 8 8 (E F S)
D i r e c t o r y of f o o d and n u t r i t i o n i n s t i t u t i o n s in the
Near East, 1 9 8 7 (E)
Residues of s o m e v e t e r i n a r y d r u g s in animals and
f o o d s , 1 9 8 8 (E)
14/12
14/13
14/14
14/15
14/16
15
16
17
18
inspection, 1981
for e x p o r t , 1 9 7 9
for e x p o r t , 1 9 9 0
analysis: general
(Ar E) (Rev. 1 9 8 4 , E S)
(E S)
(E S)
t e c h n i q u e s , additives,
29
31/2
34
37
40
41
41/2
Residues of v e t e r i n a r y d r u g s in f o o d s ,
1 9 8 5 (E/F/S)
Nutritional implications of f o o d aid: an a n n o t a t e d
bibliography, 1 9 8 5 (E)
JECFA s p e c i f i c a t i o n s for i d e n t i t y and p u r i t y of
certain f o o d additives, 1 9 8 6 (E F)
41/3
41/4
55
56
f o o d s . T h i r t y - e i g h t h m e e t i n g of t h e joint
F A O / W H O Expert C o m m i t t e e o n Food A d d i t i v e s ,
1 9 9 1 (E)
57
58
41/5
59
60
N u t r i t i o n e d u c a t i o n for t h e public, 1 9 9 5 (E F S)
Food f o r t i f i c a t i o n : t e c h n o l o g y and quality c o n t r o l ,
1 9 9 6 (E)
41/6
f o o d s . Fortieth m e e t i n g of t h e J o i n t F A O / W H O
Expert C o m m i t t e e on Food A d d i t i v e s , 1 9 9 3 (E)
Residues of s o m e v e t e r i n a r y drugs in animals and
61
62
B i o t e c h n o l o g y and f o o d s a f e t y , 1 9 9 6 (E)
N u t r i t i o n e d u c a t i o n for t h e public - D i s c u s s i o n
papers of t h e FAO Expert C o n s u l t a t i o n , 1 9 9 6 (E)
63
64
Street f o o d s , 1 9 9 7 (E/F/S)
W o r l d w i d e regulations for m y c o t o x i n s 1 9 9 5 - A
c o m p e n d i u m , 1 9 9 7 (E)
Risk m a n a g e m e n t and f o o d s a f e t y , 1 9 9 7 (E)
f o o d s . F o r t y - s e c o n d m e e t i n g of the J o i n t
F A O / W H O Expert C o m m i t t e e on Food A d d i t i v e s ,
1 9 9 4 (E)
41/7
41/8
Residues of s o m e
f o o d s . Forty-third
Expert C o m m i t t e e
Residues of s o m e
41/9
f o o d s . F o r t y - f i f t h m e e t i n g of t h e J o i n t F A O / W H O
Expert C o m m i t t e e o n Food A d d i t i v e s , 1 9 9 6 (E)
Residues of s o m e v e t e r i n a r y drugs in animals and
f o o d s . F o r t y - s e v e n t h m e e t i n g of t h e J o i n t
F A O / W H O Expert C o m m i t t e e o n Food A d d i t i v e s ,
1 9 9 7 (E)
65
Availability: November 1 9 9 7
Ar
Arabic
C
E
F
Chinese
English
French
Multil
Multilingual
Out of print
In preparation
42
42/1
Portuguese
Spanish
43
c u l t i v a t e d plants as f o o d , 1 9 8 9 (E)
Guidelines for agricultural training curricula in A r a b
c o u n t r i e s , 1 9 8 8 (Ar)
44
R e v i e w of f o o d c o n s u m p t i o n s u r v e y s 1 9 8 8 ,
45
46
1 9 8 8 (E)
Exposure of i n f a n t s and children t o lead, 1 9 8 9 (E)
S t r e e t f o o d s , 1 9 9 0 (E/F/S)
47/1
Utilization of t r o p i c a l f o o d s : cereals, 1 9 8 9 (E F S)
47/2
47/3
47/4
47/5
1 9 8 9 (E F S)
Utilization of t r o p i c a l f o o d s : t r o p i c a l oil seeds,
1 9 8 9 (E F S)
47/6
47/7
47/8
48
N u m b e r not assigned
49
50
51
52/1
C o m p e n d i u m of f o o d additive s p e c i f i c a t i o n s V o l . 1, 1 9 9 3 (E)
C o m p e n d i u m of f o o d additive s p e c i f i c a t i o n s -
52/2
V o l . 2 , 1 9 9 3 (E)
52 Add. 1
52 Add. 2
52 Add. 3
52 Add. 4
52 Add. 5
53
54
C o m p e n d i u m of f o o d additive
A d d e n d u m 1, 1 9 9 2 (E)
C o m p e n d i u m of f o o d additive
A d d e n d u m 2, 1 9 9 3 (E)
C o m p e n d i u m of f o o d additive
A d d e n d u m 3, 1 9 9 5 (E)
C o m p e n d i u m of f o o d additive
A d d e n d u m 4 , 1 9 9 6 (E)
C o m p e n d i u m of f o o d additive s p e c i f i c a t i o n s A d d e n d u m 5, 1 9 9 7 (E)
M e a t and m e a t p r o d u c t s in h u m a n n u t r i t i o n in
d e v e l o p i n g c o u n t r i e s , 1 9 9 2 (E)
N u m b e r not assigned
through
the
authorized
Group,
- --
'
'
'
- - -
'
. .
ISBN 92-5-102489-8
9
M
.87
7 8 9 2 5 1
ISSN 0254-4725
0 2 4 8 9 8
T0432E/2/9.97/500
ISSN 0254-4725
Manuals of food
quality control
1. The food control laboratory
FAO
FOOD AND
NUTRITION
PAPER
Rev. 1
Food
and
Agriculture
Organization
of
the
United
Nations
Manuals of food
quality control
1. The food control laboratory
FAO
FOODAND
NUTRITION
PAPER
14/1
Rev. 1
by
P.G. Martin
revised by
J. Weatherwax
and
P.G. Martin
Food
and
Agriculture
Organization
of
the
United
Nations
Rome, 1997
Reprinted 1997
M-87
ISBN 92-5-102489-8
FOREWORD
to
establish
a workable
food
control
system,
national
government
1.
2.
3.
4.
5.
and
analysis
staff
within
the
agency
or
No. 14/2
No. 14/3
No. 14/4
Microbiological Analysis
No. 14/5
Food
No. 14/6
No. 14/7
No. 14/8
Food Analysis:
Identity
(replaced
Inspection
In a d d i t i o n , FAO, WHO and UNEP jointly have published many guidelines and other
documents designed to further assist developing countries in forming adequate
food control systems. These publications include:
Methods of Sampling and Analysis of Contaminants in Food A Report of the Second Joint FAO/WHO Expert Consultation,
Rome - 1978
Guidelines for Establishing or Strengthening National Food
C o n t a m i n a t i o n M o n i t o r i n g Programmes - FAO Food Control
Series No. 5 - 1979
iii
Pesticide
Residues,
TABLE OF CONTENTS
FOREWORD
1.
2.
LABORATORY
2.1
2.2
2.3
2.4
2.5
2.6
2.7
3.
2
3
3
4
5
5
6
General Considerations
Basic Structure of the Building
Safety Features
Ventilation and Air Conditioning
Space Utilization
Equipment and Instruments
Utilities
Design References
7
7
10
12
13
15
16
18
LABORATORY ADMINISTRATION
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
5.
ORGANIZATION
LABORATORY DESIGN
3.1
3.2
3.3
3.4
3.5
3.6
3.7
3.8
4.
Sample Collection
Sample Receipt and Assignment
Sample Storage and Disposal
Budget
Purchasing
Supplies Management
Equipment Maintenance
Housekeeping
Training
LABORATORY
5.1
5.2
5.3
5.4
5.5
5.6
5.7
5.8
20
21
22
23
23
26
26
28
28
OPERATIONS
Workp lans
Priorities for Analysis
Analysis Assignment
Analysis Control
Analysis Reporting
Analysis Review
Method Validation
Confirming Analysis
. . . . .
29
31
31
32
32
33
34
34
6.
LABORATORY
6.1
6.2
6.3
6.4
6.5
6.6
6.7
6.8
7.
SAFETY
35
35
36
37
38
40
42
43
(QA)
Introduction
Establishing a QA Programme
QA of Reference Standards
QA of Instruments
QA of Analytical Reports
Check Sample Examination
Other QA Activities
Text References
46
46
49
. . 55
58
61
66
66
vi
1.
2.
2.1
Establishing
the
LABORATORY
ORGANIZATION
Laboratory
2.2
Organizational
The staffing
Structure
structure
of a typical
food
Head of
Analytical
Staff
control
laboratory
is as
follows:
Laboratory
Support
Staff
Administrative
Staff
2.3
Head
of the
It is
needs
Laboratory
The H e a d of the l a b o r a t o r y s h o u l d be a g r a d u a t e c h e m i s t or m i c r o b i o l o g i s t
trained in food analysis.
A postgraduate d i p l o m a particularly relevant to this
w o r k is h i g h l y d e s i r a b l e .
A l t h o u g h the d u t i e s of the h e a d of the l a b o r a t o r y
are m a n y , s o m e m a y be d e l e g a t e d and o t h e r s u n d e r t a k e n b y o t h e r p a r t s of the
food control administration.
It is therefore not appropriate to do more than
d r a w a t t e n t i o n to c e r t a i n a s p e c t s .
The o b j e c t i v e of the l a b o r a t o r y is to
analyze a large number of samples correctly, quickly and cheaply.
This means
t h a t a t t e n t i o n m u s t be paid to c a r e f u l s p e n d i n g of the b u d g e t , p r o m o t i o n of
good staff relations and maintenance of the highest possible level of technical
efficiency and expertise.
The laboratory Head may have to give evidence in court or write documents used
in c o u r t , in w h i c h c a s e he m u s t h a v e a t h o r o u g h u n d e r s t a n d i n g of food and
related law and court procedure.
There will also be involvement in c o m m i t t e e
work and relations with other organizations.
The laboratory Head is usually
the spokesman for the laboratory in many instances.
The Head must prepare work
p l a n s w i t h the i n s p e c t o r a t e and o v e r a l l food c o n t r o l a u t h o r i t i e s .
Sampling
p l a n s a g r e e d w i t h the i n s p e c t o r a t e s h o u l d aim at a r e a s of c o n c e r n and m a j o r
abuses.
In the e a r l i e r y e a r s or w h i l e the l a b o r a t o r y r e m a i n s s m a l l , the Head of the
laboratory is the one who makes most of the m a n a g e m e n t decisions.
The Head is
also the person who interacts with higher m a n a g e m e n t .
This is a most important
aspect as the laboratory m u s t be fully integrated into the executive s tructure
in a m e a n i n g f u l w a y .
It w o u l d be f u t i l e for a l a b o r a t o r y to w o r k in an
administrative v a c u u m , producing r e s u l t s s h o w i n g , for e x a m p l e , that s a m p l e s
2.4
Supervisors
S u p e r v i s o r s s h o u l d a l s o be g r a d u a t e c h e m i s t s or m i c r o b i o l o g i s t s w i t h
considerable food analysis experience.
The supervisor is the on-site manager
of the laboratory.
Having supervisors assigned to specific units or areas of
work permits the Head to more effectively plan (and execute) the total workload
of the laboratory.
S u p e r v i s o r s can be e x p e c t e d to do a n a l y t i c a l w o r k in a d d i t i o n to their
supervisory duties.
H o w e v e r , if their g r o u p e x c e e d s five p r o f e s s i o n a l
a n a l y s t s , it is best not to r e q u i r e a d d i t i o n a l a n a l y t i c a l w o r k e x c e p t for
occasional problem solving and trouble-shooting.
A reasonable m a x i m u m number
of a n a l y s t s for one p e r s o n to s u p e r v i s e is 10 to 12. T h i s can be m o r e if n o n professional support staff is added.
A supervisor's duties can include many or all of the
1.
Assisting the Head in overall
the work of the group supervised.
2.
posed
Receiving
and assigning
samples
laboratory
5.
Ensuring
do the work.
the
that
reports
the
of
6.
Ensuring that proper
followed by the group.
work
the necessary
laboratory
planning
in s o l v i n g
completed
group has
work
3.
A n s w e r i n g q u e s t i o n s and a s s i s t i n g
by individual analysts.
4.
Reviewing
recommendations.
following:
and
and
the group.
analytical
making
supplies
planning
and
problems
appropriate
equipment
practices
to
are
7.
R e c o m m e n d i n g to the Head n e w i n s t r u m e n t s or e q u i p m e n t n e e d e d , and
training needs of individual analysts.
8.
Taking appropriate disciplinary
laboratory rules or regulations.
9.
Acting
action
laboratory
when
needed
to
enforce
Supervisors should train one or more analysts in their group to serve as backups, to supervise the group in the supervisor's absence.
The back-ups should
be given some formal classroom training in supervision in addition to on-thejob experience.
A good supervisor is indispensable to the smooth operation of a laboratory.
In
s e l e c t i n g a s u p e r v i s o r , the Head m u s t k e e p in m i n d that the p r i m a r y job of a
s u p e r v i s o r is to m a n a g e , so that s k i l l s in w o r k i n g w i t h p e o p l e are m o r e
i m p o r t a n t than s c i e n t i f i c e x p e r t i s e .
T h e r e f o r e , a top a d m i n i s t r a t o r w i t h
2.5
Team
Leaders
A n o t h e r i m p o r t a n t , and o f t e n o v e r l o o k e d , p o s i t i o n is T e a m L e a d e r .
A team
leader is a senior analyst w h o h a s b e e n assigned a s m a l l g r o u p , u s u a l l y no m o r e
t h a n 4 , to do a s p e c i f i c
t a s k or t y p e of a n a l y s i s .
T h e l e a d e r h a s no
s u p e r v i s o r y functions as such, but is the c o o r d i n a t o r of the g r o u p ' s a c t i v i t i e s
and is the contact point for the supervisor.
T e a m l e a d e r s are m o s t u s e f u l w h e n a l a r g e n u m b e r of a r e p e t i t i v e type of
a n a l y s i s is to be done in a specified period of time.
This could be a specific
a n a l y t i c a l s u r v e y or a n e m e r g e n c y p u b l i c h e a l t h p r o b l e m r e q u i r i n g s c r e e n i n g
analyses.
T h e l e a d e r u s u a l l y w o r k s a l o n g w i t h the g r o u p in a d d i t i o n to the
coordinative function.
S u c h e x p e r i e n c e is o f t e n u s e f u l to d e t e r m i n e if t h e
assigned leader has potential as a future supervisor.
2.6
Analytical
Staff
The basic job of the analytical staff is to analyze the s a m p l e s received and to
issue a report.
They m a y also be required to a p p e a r in court as fact or expert
w i t n e s s e s to give e v i d e n c e in r e l a t i o n to a report.
They m a y also be called on
to o f f e r a d v i c e to i n d u s t r y and t r a d e , to a s s i s t in i m p r o v e m e n t o f f o o d
q u a l i t y , or advise on c o n f o r m i t y w i t h s t a n d a r d s or other legal r e q u i r e m e n t s .
T h i s c a n i n v o l v e t h e l a b o r a t o r y s t a f f in f a c t o r y v i s i t s a n d e v e n r e q u e s t s to
c a r r y out e x p e r i m e n t a l w o r k .
W h e t h e r or n o t the l a b o r a t o r y u n d e r t a k e s s u c h
w o r k w i l l be a m a t t e r of o r g a n i z a t i o n a l policy.
The d e c i s i o n w i l l depend on a
n u m b e r of f a c t o r s , i n c l u d i n g the a v a i l a b i l i t y of a l t e r n a t i v e facilities, the
n a t u r e of i n d i v i d u a l o w n e r s h i p ,
etc.
T h e i n t e g r i t y of the a n a l y s t
is
p a r a m o u n t , and s u p e r i o r s m u s t be i n f o r m e d of a n y c o n f l i c t of i n t e r e s t t h a t
a r i s e s . A s in t h e c a s e o f f o o d i n s p e c t o r s , it is p r o p e r f o r t h e a n a l y s t s to
have no vested interest in regulated industries.
This r e q u i r e m e n t is m a n d a t o r y
in m a n y countries.
A n a l y t i c a l staff can be d r a w n from three levels, u n i v e r s i t y g r a d u a t e s , trained
t e c h n i c i a n s f r o m t e c h n i c a n t r a i n i n g c o l l e g e s and u n q u a l i f i e d s t a f f w h o h a v e
received o n - t h e - j o b training.
The g r a d u a t e s can be c h e m i s t s , m i c r o b i o l o g i s t s ,
food scientists or fi od t e c h n o l o g i s t s .
U n i v e r s i t y d e g r e e s are only a starting
q u a l i f i c a t i o n and the-p. w i l l still be a r e q u i r e m e n t for specialized training
a n d e x p e r i e n c e in f o o d . n a l y s i s .
S t a f f s h o u l d be e n c o u r a g e d to c o n t i n u e to
w o r k for s u i t a b l e p o s t g r a d u a t e q u a l i f i c a t i o n s to e n a b l e t h e m to c o m p e t e for
h i g h e r posts in the laboratory.
S p e c i a l l y trained l a b o r a t o r y t e c h n i c i a n s w h o
h a v e f o l l o w e d a t w o to t h r e e y e a r p r a c t i c a l t r a i n i n g c o u r s e in l a b o r a t o r y
a n a l y s i s a f t e r c o m p l e t i n g s e c o n d a r y s c h o o l c a n be p a r t i c u l a r l y u s e f u l in
carrying out a n u m b e r of routine or even h i g h l y c o m p l e x food analyses.
As in
the c a s e w i t h u n i v e r s i t y g r a d u a t e s , s p e c i a l i z e d o n - t h e - j o b t r a i n i n g w i l l b e
needed for particular types of food analysis.
2.7
Support
Staff
Glassware
washing.
2.
Cleaning
and
3.
Disposal
of s a m p l e
4.
Pest
control.
5.
Heavy
lifting
housekeeping
and
maintenance.
reserves
( w h e n no
longer
required).
moving.
the
not
It is m o s t i m p o r t a n t t h a t s u f f i c i e n t p e r s o n s a r e h i r e d as s u p p o r t .
The w o r k
t h e y do m u s t be d o n e by s o m e o n e and t h i s is u s u a l l y an a n a l y s t or t e c h n i c i a n
w h e n there is i n s u f f i c i e n t support staff.
There is no fixed m o d u l e for n u m b e r s
of s u p p o r t w o r k e r s , b u t 1 5 - 2 0 % of the n u m b e r of a n a l y t i c a l s t a f f is o f t e n
sufficient.
3.
3.1
LABORATORY DESIGN
General Considerations
W h e n a new laboratory is being built, two people hold the key positions in
producing the right building at the right cost - the architect who designs it
and guides its construction, and the analyst (preferably the laboratory Head)
w h o explains the technical needs, and w o r k s in close p a r t n e r s h i p w i t h the
architect through every stage so that the end result is properly suited to the
requirements of the users.
It is not often that the analyst has the chance to
take part in the planning of a complete new laboratory, more usually he has to
make do with old or inadequate buildings. However, these are often more easily
extended, changed or adapted as the nature of the w o r k changes, than a n e w e r
building, so may in some ways be more advantageous.
Indeed, an important point
in designing a new laboratory is that provision should be made for future
expansion, however unlikely that may seem at the time. The design should also
be left as flexible as possible so that changes of emphasis in the work can be
a c c o m m o d a t e d . The laboratory should be located a w a y from urban centres and
industrial areas in order to minimize problems of contamination.
The information in this chapter was taken in part from Industrial Research and
D e v e l o p m e n t N e w s , VII No. 3, UN, N.Y., 1975.
The principles given apply to
food control l a b o r a t o r i e s in general, w h e t h e r n e w c o n s t r u c t i o n or space
converted to laboratory use.
3.2
An example of the smallest laboratory that would be adequate for a food control
programme is shown in Figure 3.1. This design was originally intended to serve
120,000 people although in general this may be regarded as too small a
p o p u l a t i o n to justify a separate laboratory.
It is intended to be part of a
larger b u i l d i n g , but the disposition of r o o m s can be changed to suit local
c i r c u m s t a n c e s . Space for essential services such as solvent storage and the
usual administrative support must also be provided.
Sample preparation should
be carried out as far as possible from laboratories working on trace analysis
and microbiology or using sensitive instruments.
It must be stressed that the
figure s h o w n is only an e x a m p l e .
New l a b o r a t o r i e s m u s t be c u s t o m - b u i l t to
cater for the needs of the situation under consideration.
It is best to allow l a b o r a t o r i e s to r e m a i n o p e n - p l a n as far as p o s s i b l e ,
including the areas used as offices. Exceptions are areas where the activities
carried out cause c o n t a m i n a t i o n or are sensitive to it, such as s a m p l e
preparation, weighing, microbiology, trace analysis and use of instruments such
as gas-liquid chromatographs and spectrophotometers.
Lack of v i b r a t i o n is important and therefore concrete is a better structural
m a t e r i a l in m u l t i - s t o r e y
buildings.
S t e e l - f r a m e b u i l d i n g s m a y cause
d i f f i c u l t y with some i n s t r u m e n t s .
A two storey laboratory adequate for a
modest food control programme is shown in Figures 3.2 and 3.3. It consists of
a ground floor m a i n l y composed of offices and services and a first floor for
analytical work.
In addition there should be a flammable solvent storage area
separate from the building. W o r k s h o p and g l a s s b l o w i n g facilities are often
advantageous and if not otherwise available should be included.
1 ni i
>
Food
additives
and
toxicants
Food
standards
and nutrition
Corridor
Overall
length
21 m
Microbiology
Media
prparai ion
Office
Balance
room
Sample
prparai ion
1vK
Entrance
6.2 m
6.2 m
Figure 3.1
A Minimum Sized Food Control Laboratory
Figure 3.2
Ground Floor Plan
(mainly office and administrative
space)
Figure 3.3
First Floor Plan
(laboratory space)
3.3
Safety
Features
The building
including :
1.
The
and
laboratory
fire
design
should
a r e a s of c o r r i d o r s
include
a number
s h o u l d be f o r m e d
of
safety
of c o n c r e t e
features
blocks.
2.
Services should include a shower sprinkler system near each d o o r w a y
so t h a t a w o r k e r c a n t a k e an i m m e d i a t e s h o w e r , c l o t h e s and a l l , in the c a s e of
a c c i d e n t a l g e n e r a l c o n t a c t w i t h c o r r o s i v e or p o i s o n o u s l i q u i d s or f i r e .
10
3.
wash
There
stations
should
be
(obtainable
built-in
from
most
eye
wash
chemical
fountains,
supply
or
at
least
portable
eye
firms).
4.
The t r a f f i c
flow,
the e g r e s s p a t t e r n and the p r o p o r t i o n s of
the
l a b o r a t o r y are a l l s a f e t y c o n s i d e r a t i o n s .
I t m u s t a l w a y s be p o s s i b l e to l e a v e
the l a b o r a t o r y s a f e l y i r r e s p e c t i v e of the i n i t i a l s i t e of a f i r e .
Serious
t h o u g h t m u s t be g i v e n to t h e n u m b e r and l o c a t i o n o f f i r e e x t i n g u i s h e r s
and
s t a n d p i p e s y s t e m s , and to the a v a i l a b i l i t y of s p r i n k l e r
systems.
5.
L a b o r a t o r i e s s h o u l d b e w e l l - l i t so t h a t t h e o p e r a t o r d o e s n o t h a v e
to p e e r too c l o s e l y o v e r p o t e n t i a l l y h a z a r d o u s m a t e r i a l i n o r d e r to see w h a t he
is doing.
T h e r e s h o u l d be a m p l e w o r k i n g s p a c e and b e n c h t o p s and o t h e r s u r f a c e s
s h o u l d be k e p t c l e a r of a l l m a t e r i a l e x c e p t t h a t i n c u r r e n t u s e .
6.
Benches are best w i t h o u t s h e l v e s , only s e r v i c e s , these being operated
from the f r o n t so t h a t the o p e r a t o r d o e s not h a v e to s t r e t c h a c r o s s the b e n c h .
I t i s s t i l l common to s e e r e a g e n t s on s h e l v i n g at t h e b a c k o f b e n c h e s ( o r a b o v e
the c e n t r e of d o u b l e - w i d t h b e n c h e s ) b u t i t i s p r o b a b l y s a f e r i f such r e a g e n t s
c a n be k e p t on s i d e - s h e l v e s or i n t r a y s w h i c h a r e b r o u g h t to t h e b e n c h as
required .
7.
F l o o r i n g n e e d s to b e o f a n o n - s l i p m a t e r i a l , r e s i s t a n t to a c i d s a n d
s o l v e n t s , b u t n o t so h a r d a s to b e t i r i n g to s t a n d on f o r a f e w h o u r s at a
time.
No m a t e r i a l i s e n t i r e l y s a t i s f a c t o r y .
W e l l - l a i d l i n o l e u m and a f i l l e d
e p o x y r e s i n on top of c o n c r e t e a r e a m o n g t h e b e s t a v a i l a b l e .
It is a d v i s a b l e
n o t to p o l i s h l a b o r a t o r y
floors.
8.
P o l l u t a n t s g e n e r a t e d w i t h i n t h e l a b o r a t o r y m u s t be r e m o v e d s a f e l y ,
q u i c k l y and e f f i c i e n t l y .
I n p a r t i c u l a r , t o x i c or n o x i o u s g a s e s m u s t be r e m o v e d
e x p e d i t i o u s l y t h r o u g h a d u c t s y s t e m t h a t d o e s n o t e x h a u s t n e a r the b u i l d i n g a i r
conditioning
intake.
9.
The b u i l d i n g must be p l a n n e d f o r s e c u r i t y .
R e s t r i c t i o n of a c c e s s i s
of c o n s i d e r a b l e i m p o r t a n c e b e c a u s e of the e x t r e m e l y v a l u a b l e and
sensitive
e q u i p m e n t u s e d i n t h e l a b o r a t o r y w o r k a s w e l l as t o p r o t e c t t h e i n t e g r i t y o f
official
samples.
10.
I t i s v e r y a d v i s a b l e to h a v e an e f f i c i e n t f i r e a n d s m o k e d e t e c t i o n
system w i t h appropriate alarms.
Common f i r e d e t e c t i o n e q u i p m e n t is
usually
e i t h e r r a t e - o f - t e m p e r a t u r e - r i s e or f i x e d - t e m p e r a t u r e d e t e c t o r u s i n g a s u b s t a n c e
of known m e l t i n g p o i n t .
T h e r e a r e a d v a n t a g e s ( a n d d i s a d v a n t a g e s ) to e a c h t y p e
of d e t e c t o r and the l a b o r a t o r y Head s h o u l d s e l e c t the one he f e e l s b e s t f i t s
his laboratory.
D e s i g n i n g a l a b o r a t o r y to a f f o r d p r o t e c t i o n a g a i n s t e v e r y k i n d o f h a z a r d w o u l d
be a l m o s t i m p o s s i b l e .
The a i m s h o u l d be to d e t e r m i n e t h e l e v e l o f s a f e t y
for
t h e most g e n e r a l a p p l i c a t i o n s and to p r o v i d e s u p p l e m e n t a r y s y s t e m s in a r e a s o f
higher h a z a r d .
A s a f e s o l v e n t s t o r a g e a r e a i s i d e a l l y s e p a r a t e from t h e l a b o r a t o r y b u i l d i n g i n
a stand-alone structure.
I t c a n be a s m a l l b u i l d i n g of one room and
some
p o s s i b l e d e s i g n f e a t u r e s a r e : ( r e a s o n s are g i v e n in p a r e n t h e s i s )
1.
materials
Construction
s u r r o u n d the
of
cement
solvents.)
blocks
or
bricks.
(Only
non-flammable
2.
For a s t a n d - a l o n e b u i l d i n g , d o u b l e w a l l s w i t h i n s u l a t i o n
between.
The e x t e r i o r
w a l l c a n be m a t e r i a l
other
than block
or b r i c k .
(Provides
i n s u l a t i o n from the sun and m a k e s a i r c o n d i t i o n i n g more e f f e c t i v e . )
3.
An e p o x y f i l m to c o v e r t h e e n t i r e
walls.
( A n y s o l v e n t s p i l l a g e w i l l p o o l and
t h e f l o o r s or w a l l s . )
11
floor plus
evaporate,
10 cm up t h e b a s e of t h e
r a t h e r than soak through
4.
A c o p p e r pipe (about 25 m m ) inside the r o o m , w h i c h goes t h r o u g h the
floor and is e m b e d d e d a b o u t 2 m in earth.
(A g r o u n d pipe to bleed off any
static e l e c t r i c i t y c h a r g e s - w h i c h o f t e n build up w h e n s o l v e n t s are poured).
All metal objects in the room are to be attached to the pipe using heavy guage
single strand copper wire.
Also, attach a short wire with an alligator clip.
(This g r o u n d s all m e t a l .
The clip is used to g r o u n d any m e t a l cans used for
s o l v e n t transfer.)
5.
grounding
Storage
pipe.
shelves of metal
and connected
by wire
the
6.
Air c o n d i t i o n i n g is e x t e r n a l , w i t h the e n t r a n c e duct at the top of
one c o r n e r of the r o o m and the exit d u c t at the b a s e of the o p p o s i t e c o r n e r .
( T h e r o o m m u s t be c o o l e d as m a n y s o l v e n t s w i l l b o i l at h o t o u t s i d e
temperatures. The air entrance on top and exit on the bottom diagonally across
the r o o m , w i l l cool the room and w i l l also serve to s w e e p and r e m o v e any
solvent fumes on the floor - solvent fumes are generally heavier than air and
will pool on the floor.)
7.
The door is of m e t a l and f i r e - r a t e d for at least one h o u r , w i t h a
positive closure.
It must seal well when closed. The door sill is at least 10
cm high.
(Fire doors are metal sheathed around cement.
The closure, the seal
and the h i g h sill all act to p r e v e n t e s c a p e of s o l v e n t , e i t h e r floor s p i l l a g e
or fumes.)
8.
An air c o n d i t i o n e r exit duct w i t h a fire b a f f l e (to p r e v e n t flash
b a c k ) and d u c t e d to exit in the o u t s i d e air at b u i l d i n g r o o f h e i g h t .
(Fumes
h a v e a b e t t e r c h a n c e of being carried a w a y by b r e e z e s and s o m e o n e s m o k i n g
nearby will not present a fire risk.)
9.
An extinguisher system,
and not water sprinklers.
3.4
which
should
Conditioning
An ordinary laboratory may have amounts of lead in the air passing through it
in a day which can be measured in milligrams.
Natural ventilation, which may
provide large quantities of air without cooling, is not generally suitable for
laboratories.
T h i s is e s p e c i a l l y true in u r b a n a r e a s w h e r e m o t o r t r a f f i c is
high.
This means that air conditioning is essential for the modern laboratory.
A i r c o n d i t i o n i n g not only p r e v e n t s s o m e f o r m s of c o n t a m i n a t i o n , it also
p r o v i d e s a s t a b l e t e m p e r a t u r e e n v i r o n m e n t for s e n s i t i v e and s o p h i s t i c a t e d
analytical instruments. Most v o l u m e t r i c g l a s s w a r e is c a l i b r a t e d at 20C and
must be recalibrated if used at significantly different temperatures.
This is
s t i l l a n o t h e r a r g u m e n t for air c o n d i t i o n i n g .
T h e i m p o r t a n c e of a i r
conditioning to overall laboratory accuracy cannot be overstressed.
The exhaust fans in fume hoods result in a negative pressure in the laboratory
and in an urban or industrial area this aggravates contamination of the whole
l a b o r a t o r y area.
A p o s i t i v e p r e s s u r e s y s t e m is c o s t l y as it h a s to be
s u f f i c i e n t l y p o w e r f u l to p r o v i d e a c l e a n filtered air s u p p l y w h i c h p a s s e s
t h r o u g h f u m e hood e x h a u s t fans as w e l l as o t h e r o u t l e t s .
V e n t i l a t i o n by
p o s i t i v e p r e s s u r e a s s i s t s the e x h a u s t fans in f u m e h o o d s and is to be
preferred.
Each f u m e hood should h a v e a s e p a r a t e fan, as there is d a n g e r of
cross c o n t a m i n a t i o n from a c o m m o n d u c t i n g s y s t e m .
Such a s y s t e m can be
essential if the vicinity of the laboratory is prone to contamination and it is
necessary to carry out low-level trace analysis.
Toxic fumes must be confined
as far as possible to fume hoods.
These should be away from cross-currents of
air and pedestrian traffic.
The recommended m i n i m u m air-flow through the open
face of a f u m e hood is 0.5 m / s e c .
V e n t i l a t i o n s h o u l d be such as to give at
least 5 air changes per hour.
12
3.5
Space
Utilization
L a b o r a t o r y s p a c e m u s t be a r r a n g e d for m a x i m u m u t i l i z a t i o n as w e l l as p r o p e r
w o r k flow.
It is usual to a l l o w about 10 square m e t e r s of laboratory space and
3 m e t e r s of b e n c h s u r f a c e p e r a n a l y s t .
An e x a m p l e of a l a b o r a t o r y for 8
a n a l y s t s is in Figure 3.4.
Sx
FC
Fr
DS
Kj
Figure
"
=
=
=
=
Soxhlet bench
fume cupboard
freezer
sink unit
Kjeldahl apparatus
3.4
N o t e that e a c h a n a l y s t h a s a l a t e r a l b e n c h a r e a to w o r k at.
T h i s f o r m a t is
termed 'peninsular' and is quite e f f i c i e n t .
An a l t e r n a t e f o r m a t uses 'islands'
w h i c h have access on all sides.
An e x a m p l e is Figure 3.5.
13
0.7b m
1.50 m
0.75 m
1.50 m
0.75 m
1.50 m
0.75 m
Consider as island
benches accessible
from every side, or
consider as the floor
space remaining, the
area B being occupied
by benches
Figure
3m
3.5
T h e o p t i m u m w i d t h f o r a s i n g l e b e n c h ( a b o u t 75 cm) i s r o u g h l y t h e s a m e as t h e
width
of
the
space
required
by a s t a n d i n g
individual.
It
is
therefore
convenient,
to c o n s i d e r t h e p r o s and c o n s o f i s l a n d b e n c h e s and
peninsular
b e n c h e s w i t h the a s s i s t a n c e of F i g u r e 3 . 5 .
I t c a n r e a d i l y be s e e n t h a t the
m a x i m u m b e n c h a r e a i s o b t a i n e d w i t h p e n i n s u l a r b e n c h e s (B a r e a s ) , h o w e v e r ,
the
w o r k i n g s u r f a c e is more a c c e s s i b l e on i s l a n d b e n c h e s (A a r e a s ) .
The
services
a r e m o r e a c c e s s i b l e f o r r e p a i r on i s l a n d b e n c h e s , b u t t h e r e i s l e s s
space
available
for s h e l v i n g
close
to t h e b e n c h e s .
In the c a s e of
peninsular
b e n c h e s , t h e a n a l y s t w o r k i n g i n a b a y h a s a c c e s s i n e f f e c t to t h r e e w o r k i n g
s u r f a c e s at o n c e and t h i s i s v e r y c o n v e n i e n t i f t h e r e a r e s e v e r a l
different
a n a l y s e s i n p r o g r e s s at the same t i m e .
H o w e v e r , the s p a c e b e t w e e n p e n i n s u l a r s
s h o u l d a l w a y s be e n o u g h for two p e o p l e to w o r k c o m f o r t a b l y b a c k to b a c k ( a b o u t
1.5 m).
I s l a n d b e n c h e s make the c h o i c e of s i t e for w i n d o w s and d o o r s
less
critical.
P e n i n s u l a r b e n c h e s m a y be p r e f e r r e d i f s p a c e i s a t a p r e m i u m a n d
t h e y may be s l i g h t l y s a f e r ,
as the r o u t e s by w h i c h p e o p l e w a l k a b o u t
the
l a b o r a t o r y t e n d to be m o r e r e s t r i c t e d and p r e d i c t a b l e .
W h i c h e v e r is c h o s e n ,
w h a t i s m o s t i m p o r t a n t i s t h a t t h e s i z e o f t h e r o o m i s c o r r e c t to t a k e a n
i n t e g r a l n u m b e r of b e n c h u n i t s w i t h t h e i r a c c o m p a n y i n g
floor space.
Usually
t h e p r o b l e m c a n be p a r t l y s o l v e d b y a w a l l b e n c h at one end or s i d e of t h e
l a b o r a t o r y but a l l too o f t e n l a b o r a t o r i e s have such a s i z e or shape t h a t f l o o r
s p a c e h a s b e e n w a s t e d , or an e x t r a b e n c h h a s b e e n i n c o n v e n i e n t l y s q u e e z e d
in.
The s t o r a g e a r e a s in the b e n c h e s s h o u l d be m o d u l a r to a l l o w f l e x i b i l i t y .
Many
laboratory
bench
manufacturers
have
units
where
the
storage
areas
are
interchangeable.
Some s a m p l e s of b e n c h a s s e m b l i e s a r e g i v e n in F i g u r e 3 . 6 ,
w i t h w i d t h s in c e n t i m e t e r s .
14
KO
ra
to
1M
(O
m m m
I
f-
"t-
22
to
'
to
110
120
4-
120
10
120
2%0
120
2$o
120
4-
2 tO
120
2so
tO
+4-
4-4-
4"
120
IM
120
4-4rara
1
II
II
4-
220
H
t-
rap nu
+
Il
ira
m m
m rap ra
era
to
M U
4-
SO (O
>0
110
4"
HI
..
Figure
--
--
'
3.6
3.6
Equipment
and
Instruments
15
a n a l y s e s so t h a t , o n c e the m a n y h u n d r e d s of i t e m s r e q u i r e d in a food c o n t r o l
l a b o r a t o r y h a v e b e e n p r o v i d e d , t h e r e c o m e s a p o i n t at w h i c h p r o d u c t i v i t y c a n
rise s h a r p l y and i n v e s t m e n t decrease.
The logistical p r o b l e m s of m a i n t e n a n c e ,
r e p a i r and r e p l a c e m e n t of e q u i p m e n t are also c o n s i d e r a b l e .
Adequate provision
m u s t be m a d e for obtaining spares and r e p l a c e m e n t parts and for their storage.
It is false e c o n o m y if staff are being paid but c a n n o t do an i m p o r t a n t part of
their w o r k due to a lack of r e l a t i v e l y i n e x p e n s i v e e q u i p m e n t .
S o m e of the i n s t r u m e n t s and e q u i p m e n t needed for c h e m i c a l a n a l y s i s by a m o d e r n
food c o n t r o l l a b o r a t o r y are:
(for purposes of this listing, ' i n s t r u m e n t s ' are
m e a s u r i n g d e v i c e s and ' e q u i p m e n t ' are p r o c e s s i n g d e v i c e s .
Apparatus made
p r i m a r i l y of glass are not included).
Instruments
A n a l y t i c a l balance
pH m e t e r
Spectrophotometer, UV-visible, double-beam
S p e c t r o p h o t o m e t e r , atomic a b s o r p t i o n
H i g h P e r f o r m a n c e Liquid C h r o m a t o g r a p h (with UV and d i f f e r e n t i a l r e f r a c t i v e
index d e t e c t o r s )
Gas C h r o m a t o g r a p h (with flame i o n i z a t i o n and e l e c t r o n capture d e t e c t o r s )
Equipment
Blender
Grinder
Pulverizing hammer mill
Air o v e n , forced draft
V a c u u m o v e n , with pump
M u f f l e furnace
Centrifuge
Refrigerator
Freezer
H e a t e r s and hot plates
Steam and w a t e r b a t h s
W a t e r still or d e i o n i z e r
3.7
Utilities
16
suggested.
The laboratory pictured in Figure 3.3 has 160 double 13-amp socket
outlets.
This apparently large n u m b e r adds considerably to the efficiency of
a n a l y t i c a l o p e r a t i o n s and to their s a f e t y .
The s a m e l a b o r a t o r y has 110 gas
p o i n t s , e x c l u d i n g t h o s e to the f u m e h o o d s .
T h e r e m u s t b e s e v e r a l cold w a t e r
taps per b e n c h to a l l o w for r i n s i n g , c o n d e n s e r s , etc., but h o t w a t e r can be
restricted to those sinks w h e r e apparatus is washed.
In a larger laboratory a
distribution system for distilled or deionized water would be advantageous.
():
suggested:
1.2
1.5
1.8
2
2
1
2
3
2
3
4
2
1
2
1
3
1
4
S p e c i a l m e t h o d s , s u c h as t r a c e a n a l y s i s , u s u a l l y r e q u i r e d i s t i l l a t i o n f r o m
g l a s s a p p a r a t u s of w a t e r i n i t i a l l y p a r t i a l l y p u r i f i e d by d i s t i l l a t i o n or
deionization.
The initial purification produces water very low in salts, but
if the o r i g i n a l s u p p l y c o n t a i n s o r g a n i c m a t t e r t h i s m a y n o t be r e m o v e d , and
traces of resin material m a y be present.
A s t e a d y s u p p l y of c o m p r e s s e d air is r e q u i r e d for an a t o m i c
absorption
s p e c t r o p h o t o m e t e r (AAS) and is v e r y u s e f u l to h a v e a v a i l a b l e at the b e n c h . A
c o m p r e s s o r is s u i t a b l e for use w i t h the i n s t r u m e n t but if used for o t h e r
purposes at the same time it m u s t be capable of supplying those needs without
a f f e c t i n g the AAS s u p p l y . A p a r t f r o m the i n a c c u r a c y that w i l l r e s u l t from a
change in the flame characteristics, sudden failure of the air m a y result in a
flashback, which is expensive if the mixing chamber is destroyed, and could be
dangerous.
H o w e v e r , it m u s t be emphasized that m a n u f a c t u r e r s design this part
of the i n s t r u m e n t to be as safe as p o s s i b l e u n d e r f l a s h b a c k c o n d i t i o n s .
Therefore, in m a n y ways it is probably better to have a separate air supply to
the AAS.
T h i s i n s t r u m e n t a l s o has to be p r o v i d e d w i t h a v e n t i l a t i o n h o o d to
remove gases formed during operation, particularly if nitrous oxide is used as
the fumes are very toxic.
Utility services require a large space but need to be concealed for aesthetic
r e a s o n s , y e t r e q u i r e an e a s y a c c e s s for r e p a i r p u r p o s e s .
To s a t i s f y t h e s e
conflicting demands, the main runs may be in voids above false ceilings and in
floor ducts.
Secondary services are then run to outlet points on benches taken
from floor level along the wall behind benches in voids especially incorporated
in the design of the bench fittings.
Frequent access points are provided for
maintenance purposes.
Drain pipes should be of high density polythene or copolymer polypropylene with
screwed joints.
T h e s e s h o w g o o d r e s i s t a n c e to m o s t o r g a n i c and i n o r g a n i c
chemicals.
The d r a i n a g e l i n e s m a y be e m b e d d e d in the f l o o r i n g . As it is not
acceptable to discharge laboratory w a s t e s d i r e c t l y i n t o t h e s e w e r a g e s y s t e m ,
all w a s t e from l a b o r a t o r y sinks and o t h e r w a s t e f i t t i n g s s h o u l d be led f i r s t
into dilution pots (about 5 litre capacity) before being released into the m a i n
sewers.
Buildings can be designed to include a large dilution tank where all
l a b o r a t o r y sink w a s t e is d i r e c t e d b e f o r e e n t e r i n g the s e w e r a g e s y s t e m .
For
laboratories with high mineral acid use, sink traps of inert duriron often work
well.
17
3.8
Design
References
1.
B e c k , H. L u f t u n g s e i g e n s c h a f t e n von L a b o r a b z u g e n ( V e n t i l a t i o n p o w e r of
laboratory fume cupboard).
Weinheim, Chemie-Ingenieur-Technik, 1964 (No.
3 6 ) (in G e r m a n ) .
2.
Be r u f s g e n o s s e n s c h a f t fur d i e c h e m i s c h e I n d u s t r i e , R i c h t l i n i e n fur
c h e m i s c h e L a b o r a t o r i e n Nr. 12 ( D i r e c t i v e s for c h e m i c a l l a b o r a t o r i e s no.
12) Weinheim, Verlag-Chemie, 1972 (in German).
3.
4.
Decken,
C.B. v.d. a n d
B. H u n d o r f .
Untersuchungen
uber
die
stromungstechnischen Vorgange in der Kapelle eines Laborabzug (Experiments
about flow within the cabin of a fume cupboard).
Darmstadt, GIT 1968 (No.
8) (in G e r m a n ) .
5.
(German
Federal
a.
piping)
b.
c.
experience:
6.
Druckgasverordnung
(in G e r m a n ) .
7.
Dunkl/Geyer.
R a t i o n a l e L o s u n g e n von L a b o r b a u und L a b o r e i n r i c h tungsprob1emen
in H o c h s c h u l e n ,
Industrieunternehmumgen
und i m
Gesundheitswesen der USA (Rational solutions of problems in the design of
laboratory building and equipment for u n i v e r s i t i e s , i n d u s t r y and p u b l i c
h e a l t h in the U n i t e d States).
In B e i t r a g e zur U n i v e r s i t a t s p l a n u n g
( C o n t r i b u t i o n s to the p l a n n i n g of u n i v e r s i t i e s ) . F r a n k f u r t / M . D E C H E M A ,
1970 (Heft 6) (in G e r m a n ) .
8.
F e u r i c h , H. R o h r n e t z e fur S a u e r s t o f f , D r u c k l u f t , V a c u u m , K o h l e n s a u r e in
K r a n k e n h a u s e r n und L a b o r a t o r i e n (Service p i p i n g for o x y g e n , c o m p r e s s e d
air, vacuum and carbon dioxide in hospitals and laboratories) Darmstadt,
G I T 1 9 6 4 (nos. 8, 9 and 10) (in G e r m a n ) .
9.
D e u t s c h e I n d u s t r i e N o r m t'DIN) ( G e r m a n
Beuth-Vertrieb G m b H (all in German)
plant;
principles,
Industrial
a.
Ventilation
English).
b.
Fire resistance
4102-1970.
c.
DIN 4034-1969.
d.
Laboratory furniture;
12 912-1973.
laboratory
of building
DIN
Standard).
materials
ceramic
18
tiles
1946-1960,
and
for
Part
structural
Berlin,
(also
elements.
bench
tops.
in
DIN
DIN
e.
DIN
12-914-1973.
f.
Laboratory
1973.
g.
L a b o r a t o r y furniture; large-size
DIN 12 916-1972.
h.
i.
j.
Laboratory
1972.
k.
Heating plant,
English).
1.
m.
furniture;
smoke
fume
tiles
cupboards,
stacks.
DIN
DIN
18
tops.
DIN 12 922-1972.
dimensions.
160-1968;
DIN
part
12
923-
1 (also
in
18-225-1958.
10.
11.
/Richtlinien fur die Planung und den Bau von Laboratorien (Principles for
design and building of laboratories) Weinheim, C h e m i e - I n g e n i e u r - T e c h n i k ,
1971. (No. 11) (in German).
12.
13.
14.
15.
16.
Unfallverhutungsvorschrift:
Medizinische Laboratoriumsarbeiten (Prescription for accident prevention: work in medical laboratories) Frankfurt/M.
H G U V V ) (in German).
17.
18.
V e r b a n d D e u t s c h e r E 1 e k t r o t e c h n i k e r ( V D E ) N o r m e n (Union of G e r m a n
E l e c t r i c a l Engineers s t a n d a r d s ) O f f e n b a c h / M a i n , Federal Republic of
Germany (in German).
19.
19
Standards
Fume-Dispersal
4.
4.1
LABORATORY ADMINISTRATION
Sample Collection
and
2.
C a r r y out g e n e r a l s u r v e y s of the q u a l i t y of the food s u p p l y t h r o u g h
random sampling and analysis, samples being taken from factories, warehouses
and retailers.
3.
Monitor certain specific problem areas with regard to food safety specific foods or classes of foods for specific potential risks, (e.g. level of
metallic contaminants, pesticide residues, mycotoxins, etc.).
4.
(if needed).
5.
Inspect
food
imports.
This
is b e s t d o n e on a l l
c o n s i g n m e n t s by f o r m a l s a m p l i n g c a r r i e d out s y s t e m a t i c a l l y in
representative of the lot.
imported
a manner
6.
Formal sampling should also be done on locally produced food products
b a s e d o n t h e f o o d i n s p e c t o r s ' o b s e r v a t i o n s , or b e c a u s e a r a n d o m o r
investigatory sample under the regular programme was unsatisfactory, or because
the product is one that requires thorough surveillance.
Analysis of formal and
informal samples is also necessary in an emergency such as an outbreak of foodpoisoning .
National sampling programmes yield important benefits in terms of efficiency.
The I n s p e c t o r a t e and the L a b o r a t o r y a s s i s t e d and g u i d e d by o t h e r a g e n c y
o f f i c i a l s or an a d v i s o r y b o a r d , as a p p r o p r i a t e , should p e r i o d i c a l l y plan
overall programmes to locate and deal with different problems in the areas of
food q u a l i t y and c o n s u m e r p r o t e c t i o n .
In each case the o b j e c t i v e s of the
p r o g r a m m e should be clearly defined.
A l t h o u g h s a m p l e s m a y be c l a s s i f i e d in a n u m b e r of w a y s , it is c o n v e n i e n t to
consider two broad divisions, "formal" samples and "informal" samples.
Formal
samples are those taken to determine if the foods comply with national or local
l a w s or r e g u l a t i o n s .
R e g u l a t o r y a c t i o n m a y r e s u l t from r e p o r t s r e c e i v e d on
such samples.
Informal samples may be taken for purposes of monitoring or as
part of survey work. Formal follow-up samples can be taken if informal samples
receive adverse laboratory reports.
Formal or informal samples will also be
taken under other circumstances, such as a follow-up to a consumer complaint.
When samples are
of the nature and
required from the
e x p e r i e n c e , from
from the r o u t i n e
20
4.2
Assignment
W h e n a food s a m p l e is r e c e i v e d for a n a l y s i s , t h e r e m u s t be a s y s t e m to t r a c k
the sample throughout it's initial storage, analysis and later reserve storage.
This is usually embodied in a record keeping system which is keyed to a unique
n u m b e r a s s i g n e d to the s a m p l e at the t i m e of s a m p l i n g .
T h i s n u m b e r c a n be
sequential (i.e. 0001 to 9999) or can be devised to give information (i.e. 0245 - 0 7 , the 2 4 t h s a m p l e t a k e n in 1 985 u n d e r s a m p l i n g p r o g r a m m e n u m b e r 7).
The
r e c o r d m u s t s h o w each m o v e m e n t of a s a m p l e , its r e c e i p t , a s s i g n m e n t to a
l a b o r a t o r y p e r s o n for a n a l y s i s , r e t u r n to the s a m p l e c u s t o d i a n , and e v e n t u a l
disposition.
One of the a d m i n i s t r a t i v e s t a f f s h o u l d be g i v e n this r e c o r d
keeping function and closely supervised by a senior administrator, as well as
supervised in general by the laboratory Head.
It is usually best to use a card record system rather than a log book as cards
are more flexibly handled and may be filed in groups under different headings.
M a n y card record systems have been devised including 5x8 cards with coded sites
on the periphery for punching.
Other cards are pre-printed with spaces to be
filled in w i t h appropriate data.
Regardless of the card system selected, there
are certain items of information which should be on each card:
1.
Sample
number.
2.
Product
3.
Date
4.
Date received
5.
Type of sample
6.
Method
7.
Storage
8.
Date assigned
9.
To whom assigned
name.
sampled.
at the
laboratory.
(survey, complaint,
of storage
etc.).
(dry, refrigeration,
location (coded
for
for easy
freezing,
etc.).
finding).
analysis.
(the analyst
10.
Date returned
(from
11.
12.
Reserve
13.
Final disposition
should
initial
to show
receipt).
analyst).
(may be different
storage method
and
from
the original
analyst).
location.
or disposal
of sample, method
21
and
date.
Note that the above uses the sample record only to record physical m o v e m e n t and
location, not analytical results.
The reason is that the analytical worksheet
and the sample record are usually in two different locations.
T h e s a m p l e r e c o r d card s h o u l d be p r e p a r e d and in the c u s t o d y of one p e r s o n
until the reserve sample is destroyed.
This person is often called the Sample
Custodian and in small laboratories could have other duties as well.
The job
of S a m p l e C u s t o d i a n is c r i t i c a l to the o p e r a t i o n of m o s t l a b o r a t o r i e s .
The
person employed in this post m u s t be very reliable, but m a y find the duties of
the job s l i g h t l y m o n o t o n o u s .
C o m b i n i n g the d u t i e s of s a m p l e c u s t o d i a n w i t h
k e e p i n g the l a b o r a t o r y s t o r e is o f t e n d o n e in m e d i u m
or l a r g e r
sized
laboratories.
The laboratory store of chemicals, glassware and other fittings
r e q u i r e s c a r e f u l c o n t r o l as d o e s r e o r d e r i n g of m a t e r i a l s in s h o r t s u p p l y ,
issuance of supplies to analysts, etc.
Combining the jobs of Sample Custodian
and S t o r e K e e p e r c a n c r e a t e a c h a l l e n g i n g and i n t e r e s t i n g p o s t .
Another
approach to the job of Sample Custodian in smaller laboratories is to split the
job b e t w e e n several people with different senior assistants under the various
section leaders being responsible for samples from a particular source, or for
particular groups of products.
W h e n a s a m p l e is a s s i g n e d , the a n a l y s t s h o u l d p h y s i c a l l y sign or i n i t a l the
s a m p l e c a r d to s h o w c u s t o d y .
W h e n a s a m p l e r e s e r v e is r e t u r n e d to the
C u s t o d i a n , the C u s t o d i a n w o u l d sign or i n i t i a l .
A f t e r a s s i g n i n g the s a m p l e ,
the S u p e r v i s o r m u s t h a v e s o m e m e a n s of t r a c k i n g s a m p l e s u n d e r a n a l y s i s w i t h
proposed or possible completion dates.
The sample card could be used for this.
The card would then be in the hands of the Supervisor during analysis and would
be returned to the Custodian on completion.
4.3
Sample Storage
and
Disposal
S a m p l e s t o r a g e , b o t h i n i t i a l and r e s e r v e , is c r i t i c a l to a s a m p l e a n a l y s i s .
Improper storage can completely i n v a l i d a t e a n y a n a l y t i c a l r e s u l t s .
Ideally,
the s a m p l e is to be s t o r e d in a m a n n e r to p r e v e n t a c h a n g e in the a t t r i b u t e
being examined, from the time of sampling, through analysis, and into reserve
storage.
To i l l u s t r a t e the i m p o r t a n c e of p r o p e r s t o r a g e , if a fresh food
sample to be examined for decomposition is not hard frozen until examination,
it very likely will decompose even further.
The analyst is then not sure how
m u c h of the d e c o m p o s i t i o n found is due to sample mishandling.
The usual storage areas are dry (room temperature storage), refrigeration and
freezing.
K e e p in m i n d t h i n g s that c a n h a p p e n d u r i n g s t o r a g e .
For e x a m p l e ,
insects or other vermin can attack dry storage, mould frequently occurs during
refrigeration, and frozen products often have "freezer burn" where the food has
desiccated.
Steps to m i n i m i z e these problems include using correct containers
(i.e. glass or m e t a l for dry storage, no paper bags), proper sample preparation
(i.e. g l a z i n g f r o z e n s a m p l e s w h e r e p o s s i b l e , to r e d u c e d e h y d r a t i o n ) , and
frequent checks on those stored samples which are m o s t subject to change.
Sample disposal is, or can be, a relatively simple matter.
The only problems
arise w h e n there is a hazard involved in the destruction, or where the sample
r e m a i n s must have special treatment.
An e x a m p l e is a s a m p l e of g r o u n d n u t s
heavily contaminated with aflatoxin.
The sample itself presents a hazard to
the disposer and may be a hazard to others if not detoxified.
The analyst best
k n o w s any h a z a r d s i n v o l v e d , so s h o u l d i n f o r m the S a m p l e C u s t o d i a n of a n y
special disposal requirements.
22
4.4
Budget
4.5
Purchasing
with
the
23
24
f r e i g h t , l o a d i n g c h a r g e s , d o c u m e n t a t i o n or e x p o r t h a n d l i n g , all of w h i c h are
charged separately.
The term f.a.s. is used to denote "free alongside ship".
If a b i d d e r d e v i a t e s from the t e r m s laid d o w n in the t e n d e r i n v i t a t i o n , h i s
o f f e r s h o u l d be c a r e f u l l y e x a m i n e d as it m a y h a v e b e e n i n t e n d e d to o b t a i n a
superficial advantage in price comparison only.
A careful technical scrutiny
of the s p e c i f i c a t i o n s g i v e n in a b i d d e r ' s o f f e r and a c o m p a r i s o n w i t h the
i l l u s t r a t e d l i t e r a t u r e a t t a c h e d to the bid w i l l , in m a n y c a s e s , e l i m i n a t e
q u o t a t i o n s w h i c h at f i r s t g l a n c e look c h e a p e r .
Accessories may have been
p u r p o s e l y left out to g a i n an a d v a n t a g e over o t h e r b i d d e r s .
Sometimes minor
b u t i m p o r t a n t d i f f e r e n c e s in p e r f o r m a n c e d a t a c a u s e c o n s i d e r a b l e
price
variations.
M a n y n a t i o n a l and i n t e r n a t i o n a l o r g a n i z a t i o n s i n v i t e o f f e r s from o r i g i n a l
manufacturers only, demand ing that the c o m m i s s ion usually allowed to agents be
offered as a discount.
The disadvantages of this procedure are that orders are
quite frequently placed w i t h firms which readily accept these conditions but
which have neither experience nor agents in the purchasing country.
Thus, the
scientists in less industrali zed countries are denied the benefit of any kind
of t e c h n i c a l a s s i s t a n c e .
W h e n c o m p a r i n g p r i c e q u o t a t i o n s , the o f f e r of an
i n t e r n a t i o n a l l a b o r a t o r y e q u i p m e n t s u p p l i e r m a y o c c a s i o n a l l y be found to b e
substantially higher than that of a manufacturer.
In such cases it can only be
r e c o m m e n d e d t h a t the e x p e r i e n c e and a f t e r - s a l e s s e r v i c e i n c o r p o r a t e d in the
offer should be carefully considered.
One aspect of equipment purchase that causes problems is the time given for the
s u b m i s s i o n of o f f e r s .
O f t e n it is far too s h o r t .
It s h o u l d be r e a l i z e d t h a t
long lists of specifications prepared for a project over an extended period of
time cannot normally be quoted for in a space of only two or three weeks - the
t i m e that m i g h t be left to a s u p p l i e r a f t e r d e l a y s in m a i l are t a k e n into
account.
The q u a l i t y of o f f e r s m i g h t be c o n s i d e r a b l y i m p r o v e d if m o r e t i m e
were allowed.
D e c i s i o n s on bid a c c e p t a n c e s h o u l d n o t be d e l a y e d b e y o n d the
n o r m a l validity of offers.
Another serious problem that is often encountered concerns damage in transit
Extensive d a m a g e and even total loss
and the insurance covering such damage.
can result from the rough handling of consignments in ports where no mechanized
m e a n s of t r a n s p o r t (such as f o r k - l i f t t r u c k s ) is a v a i l a b l e .
D e l a y s m a y be
e n c o u n t e r e d in c l e a r i n g c o n s i g n m e n t s t h r o u g h c u s t o m s , and s h e l t e r e d s t o r a g e
facilities are often quite inadequate.
Cases containing expensive equipment
m a y be s u b j e c t e d to the m o s t a d v e r s e c l i m a t i c c o n d i t i o n s - h u m i d i t y , h e a v y
tropical rains, extreme heat and dust.
No economically justifiable method of
p a c k i n g can p r e v e n t d a m a g e to e q u i p m e n t u n d e r such c o n d i t i o n s .
Sometimes,
b e c a u s e of c u s t o m s f o r m a l i t i e s and a d m i n i s t r a t i v e d e l a y s in h a v i n g the
consignments unpacked and examined, insurance coverage has already expired by
the t i m e the e q u i p m e n t a r r i v e s at its d e s t i n a t i o n and a c l a i m can be l o d g e d .
T h e n , m o r e t i m e and e f f o r t is u s u a l l y s p e n t on f i x i n g r e s p o n s i b i l i t y than on
how the situation might be avoided in the future.
Replacement parts required to repair transport damage should be obtainable with
a m i n i m u m of delay and administrative red tape.
Laboratories should have the
authority, in an emergency, to place small orders direct with suppliers.
With
or without such emergency order facilities, h o w e v e r , scientists usually depend
on (and prefer cooperation with) the experienced and flexible supplier who is
in regular contact w i t h his customer, who extends unbureaucratic help and who
even provides, when necessary, free replacements and repair facilities in order
to c o n t r i b u t e to the p r i m e o b j e c t i v e in the e s t a b l i s h m e n t of a s c i e n t i f i c
institute, useful and effective work and uninterrupted operation.
25
4.6
Supplies
Management
Name of product
Date purchased
Where purchased
Amount (including units if more than one
Expiration date (if any)
Special storage requirements (if any)
Amount dispensed.
container)
S m a l l m e t a l t a g s p a i n t e d w i t h b r i g h t c o l o u r s can be p u r c h a s e d and d i f f e r e n t
tags affixed to cards for flagging purposes.
For e x a m p l e , a red tag m a y m e a n
the supply is low and should be reordered within a given time.
Having a w o r k a b l e supplies m a n a g e m e n t s y s t e m t e n d s to p r e v e n t c i r c u m s t a n c e s
w h e r e a n a l y s e s h a v e s t o p p e d b e c a u s e a c r i t i c a l m a t e r i a l is s u d d e n l y u s e d up.
L i k e b u d g e t i n g , it is a p r o c e s s of m a i n t a i n i n g c o n t r o l of a c r i t i c a l a r e a to
promote overall smooth operation of the laboratory.
4.7
Equipment
Maintenance
W h e n the food analyst goes beyond organoleptic examinations, he or she must use
s o m e i t e m of e q u i p m e n t to p r o c e s s or to m e a s u r e the s a m p l e a t t r i b u t e of
interest.
It is critically important, therefore, that all items of equipment
be properly and promptly maintained, and repaired when needed.
T h e d e g r e e of s o p h i s t i c a t i o n of e q u i p m e n t v a r i e s d r a m a t i c a l l y from a
straightforward pH m e t e r to a complex spectrophotometer.
M a n y laboratories in
developing
countries have great difficulty
in o b t a i n i n g r e p a i r of any
e q u i p m e n t , sophisticated or otherwise.
It is therefore
reasonable to require
that proper maintenance of the equipment be routinely scheduled and completed,
hopefully to delay the day when outright repairs are necessary.
T h e b e s t c i r c u m s t a n c e , of c o u r s e , is to e s t a b l i s h an o p e r a t i n g r e p a i r and
m a i n t e n a n c e w o r k s h o p w i t h qualified technical staff.
This can be essential for
l a r g e i n s t i t u t e s h a v i n g a d i s p r o p o r t i o n a t e l y l a r g e i n v e s t m e n t in e x p e n s i v e
equipment.
E v e n in the a b s e n c e of an o r g a n i z e d w o r k s h o p , s o m e a n a l y s t s or
technicians can be given training in repair and maintenance techniques, often
by local instrument suppliers.
If adequate service is available locally, serious consideration should be given
to purchase of service contracts.
The usual service contract involves checking
the e q u i p m e n t at s p e c i f i e d i n t e r v a l s and p e r f o r m i n g n e c e s s a r y m a i n t e n a n c e .
E m e r g e n c y r e p a i r s are u s u a l l y d i s c o u n t e d in p r i c e b e c a u s e of the s e r v i c e
contract.
Service contracts are especially important for analytical balances,
to m a i n t a i n proper calibration.
A history of an instrument's maintenance and repair can become very important.
It p r o v i d e s a s u m m a r y of the i n s t r u m e n t ' s o p e r a t i o n o v e r a g i v e n p e r i o d , b u t
m o r e i m p o r t a n t l y , it can p r o v i d e a j u s t i f i c a t i o n for r e p l a c e m e n t of old and
o u t w o r n items.
Recording the cost is important as it is then readily apparent
26
w h e n an i n s t r u m e n t c o s t s m o r e to k e e p o p e r a t i n g t h a n it is w o r t h .
A preprinted
5 x 8 c a r d c a n c o n v e n i e n t l y b e u s e d to r e c o r d s u c h i n f o r m a t i o n .
An e x a m p l e of
s u c h a c a r d ( f r o n t a n d r e a r ) is s h o w n in F i g u r e s 4.1 a n d 4 . 2 .
T y p e of Machin*
MACHINE
PART I -
DETAILS
OF
HISTORY
CARD
MACHINE
B r a n d a n d Modal N o .
Vendor
L o c a t i o n of m a c h i n e
(State dept./scction)
H o w o p e r a t e d ( T i c k in appropriate b o x )
Machine N o .
C o u n t r y of Manufacture
Data of P u r c h a i e
Purchase Price
Guarantee P e r i o d
T e r m s of Guarantee
P A R T II -
Manual
Etactrk
Electronic
DETAILS OF MAINTENANCE
Service A g e n t
Per lOd
Maintenance C o n t r a c t
Name
From
Cott ($)
(per a n n u m )
To
Spare parts
included?
Yes
No
N u m b e r of
C o m m e n t o n f i r m ' service
(per a n n u m )
Figure 4.1
Front Side
F A R T HI -
OF
BREAKDOWNS
S e r v i c i n g / R e o a i r details
(State cause of b r e a k d o w n a n d
parts c h a n g e d , etc!
Date
P A R T IV
OETAILS
COMMON D E F E C T S
I d n c n b * with d . u i l i
pm
Response
time of
Service A g e n t
f r * j . n y . cHactsl
Figure 4.2
Rear Side
27
Cumulative
Cost
C o s t of
Repair
Time taken
to repair
4.8
Housekeeping
4.9
Training
28
5.
5.1
LABORATORY
OPERATIONS
Workplans
T h e a n n u a l w o r k p l a n is the c o r n e r s t o n e to m a n a g i n g a food c o n t r o l l a b o r a t o r y .
It p r o v i d e s a m e a n s of e s t i m a t i n g s t a f f a n d r e s o u r c e s n e c e s s a r y to do a f i x e d
n u m b e r of a n a l y s e s .
C o n v e r s e l y , g i v e n a f i x e d s t a f f , the w o r k p l a n can e s t i m a t e
h o w m u c h w o r k can be d o n e .
W o r k p l a n d a t a is a l w a y s o n l y an e s t i m a t e , a l t h o u g h its a c c u r a c y o f t e n
w i t h u s e d u e t o r e f i n i n g o f t i m e m o d u l e s u s e d in c a l c u l a t i o n s .
i m p o r t a n t t i m e m o d u l e s in w o r k p l a n n i n g are:
improves
The two
1.
T h e a n a l y s t p r o d u c t i v e y e a r : T h i s is t h a t t o t a l t i m e i n a n a v e r a g e
year that one a n a l y s t s p e n d s doing o n l y s a m p l e a n a l y s i s .
Time spent during
w o r k h o u r s d o i n g o t h e r t h i n g s is d e d u c t e d .
A n e x a m p l e of t h e d e t e r m i n a t i o n of
t h i s m o d u l e is as f o l l o w s :
Total
time a v a i l a b l e
(based
on 4 0 h o u r w o r k
week)
2080 hr s
time
(2080 -
80
40
80
200
80
400
880
hr s
hrs
hr s
hrs
hrs
hrs
hrs
1200 hrs
880)
laboratory
can
T h e a b o v e t i m e d e d u c t i o n f i g u r e s w e r e t a k e n for e x a m p l e p u r p o s e s o n l y .
Each
i n d i v i d u a l l a b o r a t o r y w i l l be d i f f e r e n t .
In d e t e r m i n i n g d e d u c t i o n s , c o n s i d e r
the f o l l o w i n g :
a.
Holiday
time
is u s u a l l y
fixed
b.
I l l n e s s and p e r s o n a l t i m e a v e r a g e s can be t a k e n f r o m
staff
The
a d m i n i s t r a t i v e r e c o r d s f o r t h e p r e c e e d i n g o n e or t w o y e a r s .
a v e r a g e of the p r e v i o u s y e a r is b e s t u s e d as the m o d u l e . T h e r e a s o n
is that the s t a f f u s u a l l y h a v e m o r e p e r s o n a l t i m e m a d e a v a i l a b l e to
t h e m as t h e i r s e n i o r i t y i n c r e a s e s .
c.
M a n a g e m e n t m u s t d e c i d e h o w m u c h t i m e w i l l be set a s i d e e a c h y e a r for
t r a i n i n g . N o t e in the e x a m p l e t h a t t r a i n i n g t i m e is a b o u t 10% of the
t o t a l . If the s t a f f is r e l a t i v e l y y o u n g and i n e x p e r i e n c e d , m o r e t i m e
w i l l be r e q u i r e d .
C o n v e r s e l y an a l l - s e n i o r s t a f f m a y r e q u i r e l e s s .
d.
A d m i n i s t r a t i v e t i m e is d i f f i c u l t to e s t i m a t e as t h e r e are u s u a l l y few
or no r e c o r d s to go b y .
It i n c l u d e s t i m e a s a c t i n g
supervisor,
general
library reading,
and o t h e r a s s i g n e d
or
incidental
administrative activities.
e.
O t h e r n o n - a n a l y s i s t i m e is also o n l y an e s t i m a t e , a l t h o u g h s o m e t i m e
r e c o r d s m a y be a v a i l a b l e .
It i n c l u d e s g e n e r a l r e s e a r c h o r m e t h o d
development
activities,
quality
assurance
work,
equipment
m a i n t e n a n c e , t i m e s p e n t s e r v i n g as a t r a i n e r , a n d a n y o t h e r n o n a n a l y s i s w o r k time not included e l s e w h e r e .
29
by government
policy.
2.
T h e a n a l y t i c a l h o u r s r e q u i r e d per s a a p l e :
The f i r s t step is to
d e f i n e w h a t is i n c l u d e d in a s a m p l e a n a l y s i s , as t h i s o b v i o u s l y a f f e c t s the
total time.
Activities which are suggested to be included are:
a.
preparation.
b.
Analysis.
c.
M e t h o d d e v e l o p m e n t or p r o b l e m s o l v i n g r e q u i r e d of a g i v e n s a m p l e .
(As o p p o s e d to g e n e r a l d e v e l o p m e n t or r e s e a r c h , w h i c h w o u l d b e
included in non-analysis time.)
d.
S t a n d a r d i z a t i o n a c t i v i t i e s r e l a t e d to a g i v e n s a m p l e .
standard solutions and curves for example.)
e.
Preparation
of analytical
report and
(Preparing
calculations.
The next step is to prepare a list of all the different analyses conducted and
e s t i m a t e individual analytical times based on experience.
If some analyses are
d o n e b y t e a m s in a p r o d u c t i o n - 1 i n e a r r a n g e m e n t , e s t i m a t e the t o t a l t i m e
required by totalling the time and correcting to an individual analyst basis.
For e x a m p l e , if 4 analysts working as a team can produce 32 completed samples
in an 8 h o u r p e r i o d ,
t h e n t h e a v e r a g e a b s o l u t e s a m p l e t i m e is 0.25
hours/analysis.
H o w e v e r , it required 4 analysts and to correct the time to an
i n d i v i d u a l a n a l y s t b a s i s - 4 x 0.25 = 1.0 h o u r s / ana 1 ys i s . T h i s w o u l d be the
figure used in calculations.
*
The laboratory is now able to make good estimates on what and h o w m u c h work can
be d o n e .
It is a s i m p l e m a t t e r of m u l t i p l y i n g the n u m b e r s of a n a l y s t s
a v a i l a b l e d u r i n g the y e a r t i m e s the p r o d u c t i v e y e a r t i m e m o d u l e to g a i n the
total analytical hours available.
This can then be spread among the types of
a n a l y s e s to be d o n e , u s i n g the h o u r s / a n a l y s i s m o d u l e s .
A l t h o u g h m a n y of the
m o d u l e s are e s t i m a t e s , it is still a better and m o r e accurate w a y to d e t e r m i n e
w h a t can be d o n e , than r e l y i n g on m e m o r y and s h e e r g u e s s e s .
( R e g a r d i n g the
n u m b e r s of a n a l y s t s a v a i l a b l e d u r i n g the y e a r , k e e p in m i n d t h a t t h i s m a y
change by new hires or projected losses, so include these future projections in
the annual estimate).
T h e a b o v e c a l c u l a t i o n m e c h a n i c s of a w o r k p l a n do not a d d r e s s the m e a n s of
d e c i d i n g the a n n u a l w o r k p r i o r i t i e s .
T h i s is u s u a l l y d o n e in p a r t b y
organizational policy and in part by m e e t i n g s of senior operational managers,
s u c h as the L a b o r a t o r y and I n s p e c t o r a t e H e a d s .
All p l a n n e d w o r k and t i m e
modules depend on proper work scheduling and flow.
If samples are collected
too fast or too slow, the laboratory efficiency suffers.
There m u s t therefore
be an extremely close working relationship and liaison b e t w e e n the inspectorate
and l a b o r a t o r y .
No work plan would be complete without some form of contingency planning.
The
o l d a d a g e s t a t e s t h a t , "... If s o m e t h i n g c a n go w r o n g , it w i l l
...".
T h e r e f o r e , t h e r e s h o u l d be at least a p r o v i s i o n in a a n n u a l w o r k p l a n for
e m e r g e n c i e s or u n e x p e c t e d p r o b l e m s .
A m a j o r p u b l i c h e a l t h d i s a s t e r , for
e x a m p l e , could require an all-out laboratory effort, negating workplan work for
some period of time.
The contingency plan would simply and clearly state w h a t
t y p e s of a n a l y s e s ( u s u a l l y the l o w e s t p r i o r i t y ) w o u l d be e l i m i n a t e d in the
event of an emergency.
30
5.2
Priorities
for
General analytical
laboratory policy.
Analysis
Priority 1
Poisonings or
public health
Priority 2
K n o w n or
resulting
Priority 3
Informational
injury complaints
analyses.
s u s p e c t e d law or
in direct injury.
surveys
and
health
other
emergency
violations,
or
not
work.
M o s t of the w o r k of a l a b o r a t o r y is u s u a l l y in the t h i r d p r i o r i t y c a t e g o r y ,
with a smattering of priority two and only infrequently, priority one.
W i t h i n a g i v e n p r i o r i t y , the w o r k c a n be s u b - g r o u p e d by r e l a t i v e i m p o r t a n c e .
It is conceivable that work of very low importance never gets done because of
the continuing press of higher priority analyses.
If it appears that such is
the c a s e , the s u p e r v i s o r m u s t a d v i s e the H e a d of the p r o b l e m s and s u g g e s t
r e v i s i o n of the p l a n n e d w o r k load for the s u p e r v i s o r ' s g r o u p .
The w o r k p l a n s
discussed in the previous Section often undergo mid-year or periodic revision
based on such happenings.
5.3
Analysis
Assignaient
31
e x p e r i m e n t a l d e t a i l s in the m e t h o d as published.
R e f e r e n c e to the source w i l l
usually resolve such difficulty.
It is n o t a l w a y s n e c e s s a r y
to u s e a
collaborated method.
H o w e v e r , s u c h m e t h o d s s h o u l d be f i r s t c h o i c e if the
p a r a m e t e r is b e i n g d e t e r m i n e d in t h e l a b o r a t o r y f o r t h e f i r s t t i m e or if a
p r o d u c t has not been a n a l y z e d p r e v i o u s l y .
It is i m p o r t a n t to f o l l o w the
p r o c e d u r e s ior v a l i d a t i n g a m e t h o d .
M a n y o t h e r m e t h o d s m a y be e q u a l l y g o o d ,
but m a y not, for v a r i o u s reasons, have been subjected to c o l l a b o r a t i v e studies
or r u g g e d n e s s t e s t s .
As a r e s u l t
the a n a l y s t m a y run into
unexpected
d i f f i c u l t i e s if he h a s to t a k e the m e t h o d d i r e c t l y f r o m a b o o k .
If a m e t h o d
has b e e n in use and found to give r e l i a b l e results it should not be changed for
another
until
the n e w m e t h o d
has been s h o w n
to be of e q u a l or b e t t e r
r e l i a b i l i t y in that p a r t i c u l a r l a b o r a t o r y ( i r r e s p e c t i v e o f i t s c o l l a b o r a t i v e
status).
C o n s i d e r a b l e stress is quite r i g h t l y put on c o l l a b o r a t i v e testing at
the p r e s e n t t i m e , but it should not be f o r g o t t e n that a r e l i a b l e m e t h o d is only
a p r e c o n d i t i o n to o b t a i n i n g the r i g h t a n s w e r .
T h e a b i l i t y of the a n a l y s t to
use the m e t h o d
is the e s s e n t i a l r e q u i r e m e n t
and the p e r s o n t a k i n g
the
r e s p o n s i b i l i t y for the result, w h e t h e r the analyst h i m s e l f or the s u p e r v i s o r ,
m u s t be c o n f i d e n t of this.
5.4
Analysis
Control
C o n t r o l is a v e r y i m p o r t a n t s u p e r v i s o r y f u n c t i o n .
It is n o t s u f f i c i e n t to
s i m p l y a s s i g n w o r k and w a i t for r e s u l t s .
T h e r e m u s t be s o m e type of a c t i v e
control in the form of expected c o m p l e t i o n datas, f o l l o w - u p i n q u i r i e s , or other
i n d i c a t i o n s of active interest.
This does not m e a n p e e r i n g over the a n a l y s t ' s
s h o u l d e r , but it does m e a n that the s u p e r v i s o r has c e r t a i n fixed e x p e c t a t i o n s
on w o r k c o m p l e t i o n and e n f o r c e s those e x p e c t a t i o n s .
T h e r e are several m e t h o d s of control but one of the m o r e e f f e c t i v e is also one
of the s i m p l e s t .
The s u p e r v i s o r p r e p a r e s a card for each a n a l y s t .
When a
s a m p l e is a s s i g n e d to the a n a l y s t , the s a m p l e n u m b e r is r e c o r d e d on the c a r d
along w i t h a p r o j e c t e d date of c o m p l e t i o n .
W h e n an a n a l y s i s report is r e c e i v e d
the entry is lined through.
W h e n a'card has been filled, it is discarded and a
n e w one p r e p a r e d .
The p r o j e c t e d c o m p l e t i o n d a t e r e p r e s e n t s t h e s u p e r v i s o r ' s
e s t i m a t e of an a c c e p t a b l e analysis t i m e , a s s u m i n g no p r o b l e m s .
The s u p e r v i s o r
s c a n s t h e c a r d s of a l l a n a l y s t s e v e r y d a y or so a n d if a d a t e h a s e x p i r e d b u t
no report r e c e i v e d , the supervisor inquires of the s a m p l e status.
The analyst
m a y be h a v i n g d i f f i c u l t y a n d h a d n o t m e n t i o n e d it.
A f t e r d i s c u s s i o n , the
s u p e r v i s o r d e c i d e s if a n a l y s i s s h o u l d c o n t i n u e and if so, a s s i g n s a n e w
projected c o m p l e t i o n date.
The s u p e r v i s o r m u s t also a s s i g n n e w dates w h e n
ongoing w o r k m u s t be interrupted by a s s i g n m e n t of h i g h e r p r i o r i t y analyses.
5.5
Analysis
Reporting
32
from Roman and c o m m o n law that the report or certificate of the analyst assumes
greater importance.
U n d e r b o t h R o m a n and U.S.A. l a w the e n t i r e l a b o r a t o r y
records relating to the sample must be capable of wi ths tand ing the scrutiny of
the c o u r t and d e f e n s e l a w y e r s .
The p r a c t i c a l e f f e c t of t h e s e d i f f e r e n c e s is
not great. Under any system it is necessary for the regulatory chemist to have
legally impeccable laboratory data records and to report against samples in a
w a y that is u n d e r s t a n d a b l e to the l a y m a n , b r i e f , s u c c i n c t , and free from
irrelevancy.
T h e f o r m a t of an a n a l y s i s r e p o r t is d i c t a t e d by the a d m i n i s t r a t i v e and legal
needs of the organization.
The report form should be preprinted with blocks or
l i n e s of i n f o r m a t i o n p l a c e d in d e s i g n a t e d a r e a s on the f o r m .
This p e r m i t s
faster and m o r e uniform write-up, as well as easier final review (the reviewer
knows where to look on the form for different information).
A complete report
form would have spaces for the following information:
Sample number
Product name
Product description and amount
Date received for analysis
Labelling (if any)
Analysis method used
Analysis results
Reserve product amount
Date completed
Total analysis time in hours (if needed
for time
modules).
Raw work data and standardization information can be placed on the reverse side
of the analysis report or can be kept separately in notebooks.
In any case it
s h o u l d be a c c e s s i b l e to the r e v i e w e r in the e v e n t of q u e s t i o n .
It is b e s t to
include all raw data so that the entire sequence of work can be reconstructed
later if needed.
Calculations m u s t be clear w i t h all equations stated.
There
is no w a y to d e t e r m i n e if a c a l c u l a t i o n is c o r r e c t w i t h o u t c h e c k i n g the
T h i s , of c o u r s e , m e a n s
c a l c u l a t i o n s y s t e m u s e d , as w e l l as the a r i t h m e t i c .
that all dilutions or other operations affecting the final calculation must be
clearly stated in the raw data.
R e s u l t s m u s t a l w a y s be r e p o r t e d o n l y to a n u m b e r of s i g n i f i c a n t
figures
j u s t i f i e d by the a c c u r a c y and p r e c i s i o n of the m e t h o d .
In g e n e r a l , it is
p r u d e n t to r e p o r t to as few s i g n i f i c a n t f i g u r e s as p o s s i b l e c o n s o n a n t w i t h
stating the facts the report has to convey.
For e x a m p l e , for most purposes it
m a y be a d e q u a t e to r e p o r t a s a m p l e as c o n t a i n i n g "not less ( m o r e ) than 70
percent of y".
The report m u s t be clear and confined to factual information,
and statements which cannot be substantiated must not be made.
5.6
Analysis
Review
33
5.7
Method
Validation
5.8
Confirming
Analysis
W h e n an o r i g i n a l a n a l y s i s s h o w s the s a m p l e to be in v i o l a t i o n of l a w or
regulations in some m a n n e r , the supervisor m u s t decide if a second analysis by
the o r i g i n a l a n a l y s t is n e e d e d .
T h i s s h o u l d o n l y be d o n e if t h e r e is s o m e
doubt that the original analysis w a s done correctly.
In the event that there are no apparent errors in the original analysis, then a
c o n f i r m i n g a n a l y s i s b y a s e c o n d a n a l y s t s h o u l d be d o n e as f o l l o w s :
A fresh
p o r t i o n of s a m p l e s h o u l d be p r e p a r e d ( u n l e s s it is n e c e s s a r y or d e s i r a b l e to
u s e the o r i g i n a l ) and a n a l y z e d u s i n g a s e c o n d m e t h o d (if p o s s i b l e ) and n e w
standard reference material.
If the a d v e r s e f i n d i n g s are r e p e a t e d by the
c o n f i r m i n g analyst, then it is extremely likely that a violation exists.
If,
h o w e v e r , t h e r e is no c o n f i r m a t i o n , then the s u p e r v i s o r m u s t m e e t w i t h b o t h
a n a l y s t s and d e c i d e w h a t is to be d o n e .
It m a y be t h a t the m e t h o d s are n o t
c o m p a t i b l e , if so a recheck using the original method might be in order.
It is
a l s o o f t e n v e r y u s e f u l to c r o s s c h e c k the s t a n d a r d s u s e d b y e a c h a n a l y s t to
ensure they compare.
Confirming analysis is basically an attempt to ensure that any violation of law
The e n f o r c e m e n t laboratory
or regulation has substance and is not a mistake.
c a n n o t a f f o r d to m a k e any m i s t a k e s , so it is n e c e s s a r y to p r o v e that all
adverse results are correct.
34
6.
6.1
The Safety
LABORATORY
SAFETY
Programme
The Head of the laboratory and supervisors must emphasize to all the laboratory
staff, their c o m m i t m e n t and d e t e r m i n a t i o n to e n s u r e s a f e l a b o r a t o r y w o r k i n g
conditions.
One staff m e m b e r s h o u l d be a p p o i n t e d the " S a f e t y O f f i c e r " and
given the responsibility to m o n i t o r safety procedures, practices and equipment
on a routine periodic basis.
In a large laboratory, the Safety Officer may be
assisted by a c o m m i t t e e of two or three analysts.
The d u t i e s of the S a f e t y O f f i c e r (and c o m m i t t e e w h e r e a p p r o p r i a t e ) s h o u l d be
d e t a i l e d in the l a b o r a t o r y S a f e t y P r o g r a m m e .
This p r o g r a m m e would indicate
safety requirements, hazards, equipment and emergency procedures.
Items which
can be included in a laboratory Safety P r o g r a m m e are discussed in the following
sections.
It should be r e m e m b e r e d that the Head h a s the final a u t h o r i t y as
w e l l as r e s p o n s i b i l i t y for l a b o r a t o r y s a f e t y , so t h a t the S a f e t y O f f i c e r m a y
only make recommendations.
6.2
Basic
Safety
Rules
equipment,
f i r s t aid
2.
Before beginning a sample analysis, review possible hazards connected
w i t h the a s s i g n m e n t and take the n e c e s s a r y p r e c a u t i o n s to e l i m i n a t e or
counteract the hazard.
3.
Use, when appropriate, the safety equipment provided for protection,
(e.g., s a f e t y g o g g l e s ; face s h i e l d s ; v a r i o u s t y p e s
of g l o v e s ) .
Wear a
laboratory coat routinely since its purpose is to serve as protective clothing.
4.
Bring all accidents and hazardous
supervisor or Head immediately.
conditions
to the attention of
the
5.
W h e n l i f t i n g h e a v y o b j e c t s , use the legs i n s t e a d of the b a c k .
Bend
the knees and hold the back straight so that the lifting effort is accomplished
w i t h the legs r a t h e r than the back.
L i f t s l o w l y to j u d g e the w e i g h t of the
object.
If too heavy, obtain assistance and/or use a lifting device.
6.
Be
jewelry (like
equipment.
entangled in
7.
T u r n off l a b o r a t o r y s e r v i c e s (gas, w a t e r , etc.) at the s e r v i c e c o c k
w h e n not in use. Changes in pressure m a y suddenly dislodge tubing connected to
an apparatus and lead to an accident or possible injury.
8.
Always use mechanical aids, such as safety bulbs
when pipetting hazardous material.
Never use the mouth.
35
or pipette
fillers,
9.
Use fume hoods for any analytical operations
of solvents, or w h e n noxious fumes will be generated.
their
10.
Keep the
contents.
work
area
neat
11.
Any chemicals, whether
m u s t be washed off immediately.
even
12.
Keep fire escape
temporarily.
routes
and
tidy,
toxic
and
13.
No one s h o u l d w o r k a l o n e
available in the event of accident.
with
or not,
doors
in the
all
which
clear
involving
large
containers
are
at all
laboratory,
labelled
spilled
times.
so that
amounts
on
the
Do not
with
hands
block,
assistance
is
14.
The last person to leave the laboratory at the end of the working day
m u s t c h e c k that all e q u i p m e n t t h a t s h o u l d be t u r n e d o f f h a s b e e n .
(This d o e s
not release each individual operator from his duty to turn off the equipment no
longer in use.)
The laboratory Head in consultation with staff m a y prefer to
operate a duty roster for opening the laboratory in the morning and closing at
the end of the w o r k i n g day.
6.3
Fire
Safety
36
6.4
Chemical
Hazards
All c h e m i c a l s s h o u l d be c o n s i d e r e d as p o t e n t i a l l y h a z a r d o u s and s h o u l d be
treated with caution.
As far as possible, dangerous c h e m i c a l s should be stored
away from the laboratory and away from others with which they violently react.
Y e l l o w p h o s p h o r u s and p i c r i c acid m u s t be k e p t u n d e r w a t e r , s o d i u m and
potassium metal under oil.
Explosive peroxides can be formed in diethyl ether.
T h e y s h o u l d a l w a y s be r e m o v e d if f o u n d to be p r e s e n t , as an e x p l o s i v e
concentration
of p e r o x i d e m a y b e f o r m e d
if t h e e t h e r is d i s t i l l e d .
Distillation should be stopped while there is plenty of solvent remaining in
the d i s t i l l a t i o n flask and care s h o u l d be t a k e n not to o v e r h e a t the flask.
D u s t m a y c a u s e the e x p l o s i v e d e c o m p o s i t i o n of h y d r o g e n p e r o x i d e of o v e r 30
percent concentration.
Peroxides in general can be explosive, and must not be
allowed to come into contact with reducing agents or f l a m m a b l e solvents.
They
should be kept in dark bottles in a refrigerator.
Hydrogen fluoride solution
is e x t r e m e l y dangerous as contact w i t h the skin may result in lesions that fail
to heal.
Disposable plastic gloves must always be worn when this solution is
being handled.
Calcium gluconate gel or solution or another antidote should be
available in the first-aid cabinet.
Toxic levels of nitrogen dioxide can be produced during the use of the nitrous
oxide-acetylene flame in atomic absorption spectrophotometry and consequently
ventilation must be good.
The recommended threshold limit value (TLV) for 40
m i n u t e s exposure is 5 ppm.
Tubes for testing contaminated air
are available
c o m m e r c i a l l y from laboratory supply firms.
It is important that bottles containing sodium and potassium (for example w h e n
these have been used for drying ether) are
not left near a washing-up area in
case an inexperienced or unobservant person attempts to wash the bottle in the
37
u s u a l way.
In fact, all c o n t a i n e r s ( b e a k e r s , e t c ) c o n t a i n i n g h a z a r d o u s
material must first be rinsed or otherwise treated by the analyst to remove the
h a z a r d , b e f o r e giving to g l a s s w a r e w a s h i n g .
The need for this is o b v i o u s
as the analyst is the only one who knows of the hazard and how to eliminate it.
All reagent bottles, flasks or other containers must be properly labelled, even
if the c o n t e n t s are c o n s i d e r e d h a r m l e s s .
A d h e s i v e w a r n i n g s t i c k e r s can be
p u r c h a s e d from c h e m i c a l s u p p l y f i r m s .
T h e s e can be used in a d d i t i o n to the
container label to highlight hazards.
When emptying acids and chromic acid cleaning solutions into the drains, first
fill the sink with water, pour the acid or cleaning solution into the sink, and
then let the w a t e r run out.
A l l o w the tap to r e m a i n on full for a few
additional minutes.
Dilution should always be sufficient to reduce the acid
concentration to less than one normal.
Store acid containers in inert trays if
the acid c o n c e n t r a t i o n is g r e a t e r than 2N. P o l y e t h y l e n e t r a y s are s u i t a b l e .
Handle concentrated ammonium hydroxide and solutions of potassium and sodium
hydroxide which are ION or above as if they were concentrated acids and observe
the s a m e p r e c a u t i o n s as for acids. Do not store A L K A L I in the s a m e tray w i t h
ACID.
Do not store concentrated alkalies in glass-stoppered bottles.
6.5
Biological
Hazards
Reference
Aflatoxins
Potent
carcinogen
6,7
Potent
carcinogen
1,2,6
Asbestos
Carc inogen
Auramine, or 4,4'dimethylaminobenzophenonimide
Suspected
carcinogen
2,6
Benzene, benzol(e)
Suspected
carcinogen
4,5,6
Benzidine,
diamide,
Potent
carcinogen
2,6
Potent
carcinogen
Suspected
Carbon
Carc inogen
4,4'-biphenyldiaminobiphenyl
tetrachloride
Suspected
salts (3 and
6+)
Carc inogen
38
3,6
carcinogen
6,9
6
carcinogen
3,6,7
Ne
Catetory
Reference
Care inogen
3,4,6
DDT
Suspected
(p,p*
or o,p')
o-Dianisidine
Care inogen
Diazomethane
Suspected
Dichloroethane
Carcinogen
4-Diethylaminoazobenzene
(Butter Y e l l o w )
Suspected
N,N-Dimethylnitrosamine
Potent
Dimethyl
Carcinogen
sulphide
1,4-Dioxane
ether
(diethylene
carcinogen
2,6
carcinogen
4,5,6
-
carcinogen
carcinogen
6,8
-
6,9
Carcinogen
Teratogen
Formamide
5,6
Suspected
carcinogen
Suspected
carcinogen
2,6
Mineral
Carc inogen
3,6
1-Naphthylamine
(1-amino-naphthalene)
Care inogen
2,6
2-Naphthylamine
(2-amino-naphthalene)
Potent
Nickel
Carcinogen
4,6
Nitrobenzene
Carcinogen
Nitrosamines
Potent
Patulin
Suspected
carcinogen
Rhodamine B
Suspected
carcinogen
Suspected
carcinogen
Magenta
acid or Acid
oils
and
fuchsin
(heavy)
salts
Sodium diethyl
Soot, carbon
dithiocarbamate
black
carcinogen
carcinogen
Carcinogen
1,2,6
3,6
Tannins
Suspected
carcinogen
5,6
Thioacetamide
Suspected
carcinogen
4,5,6
Thiourea
Suspected
carcinogen
4,5,6
Trichloroethylene
Suspected
carcinogen
Vinylchloride
Carcinogen
Zearalenone
monomer
Suspected
39
10
carcinogen
11,12
in the listing
are:
1.
2.
C h e s t e r B e a t t y R e s e a r c h I n s t i t u t e (1966).
" P r e c a u t i o n s for L a b o r a t o r y
Workers who handle Carcinogenic Aromatic Amines."
The Institute, London;
reprinted with additional notes 1971, i. 7 pp.
3.
Clayson, D.B.
4.
D e w h u r s t , F. (1972).
10, 57-85, passim.
5.
Hueper,
Cancer."
6.
7.
8.
S e a r l e , C.E. (1972).
9.
10.
Maltoni,
11.
Ueno, Y. and Kubota, K., (1976), Cancer Research, 36_ (2) 445-451.
12.
6.6
Physical
(1962).
"Chemical Carcinogenesis."
"Carcinogens
C.C. T h o m a s ,
Churchill.
in the L a b o r a t o r y . "
Carcinogenesis
and
and
other
Hazards
Glassware Handling
1.
Do not use b r o k e n or chipped g l a s s w a r e or r e t u r n it to s t o r a g e .
If
it is b e y o n d r e p a i r , d i s p o s e of it. W h e n in d o u b t r e g a r d i n g p r o p e r d i s p o s a l ,
consult the supervisor.
Always use gloves in handling broken glass.
2.
R e m o v e s h a r p or jagged e d g e s from g l a s s w a r e b e f o r e u s i n g it.
polish the edges on all glass tubing.
Fire
3.
Broken glass in sinks present a definite hazard since glass may not
be v i s i b l e in the p r e s e n c e of w a t e r .
W h e n b r o k e n in the sink, r e m o v e it
promptly.
F u r t h e r m o r e , c o n s i d e r the p o s s i b i l i t y of the p r e s e n c e of b r o k e n
glass when reaching into the sink for any purpose.
40
4.
Inserting tubing into stoppers or rubber tubing can result in serious
cuts, which can be prevented if the following precautions are observed:
a.
b.
c.
d.
e.
5.
To remove glass tubing or thermometers from rubber, preferably cut
a w a y the r u b b e r . T h i s is p a r t i c u l a r l y true if the t u b i n g or s t o p p e r has b e e n
in place over an extended period of time or has been subjected to heat.
6.
In handling beakers, support them by grasping around the sides, never
over the top. If one hand will not reach more than half way around the beaker,
use both hands. Support large beakers (one litre or more) from the bottom when
in use.
7.
W h e n h e a t i n g l i q u i d s in g l a s s by m e a n s of a gas f l a m e , p r o t e c t the
glass from direct contact with the flame by use of a wire gauze or a centered
wire gauze.
8.
W h e n p l a c i n g l i q u i d s in b o t t l e s w h i c h h a v e a p o s i t i v e c l o s u r e ,
reserve more than 5 percent of the volume as air space to allow for expansion
due to temperature changes.
9.
Do not force s t o p c o c k s or ground g l a s s s t o p p e r s .
Use a s t o p c o c k
puller.
If the n a t u r e of the c o n t e n t s of the v e s s e l p e r m i t s , cool the shell
until the plug is cold, then heat the shell of the joint momentarily.
Withdraw
the plug quickly before it too has been expanded by the heat.
Vacuus Operations
1.
Protect glassware under vacuum from physical
cracks and result in collapse with explosive violence.
2.
Do not subject flat-bottom flasks
heavy walls specifically for such service.
unless
to vacuum
cause
constructed
with
3.
Guard s t a n d a r d - w a l 1 ( s p h e r i c a l ) flasks larger than one l i t r e , w h e n
used in v a c u u m s e r v i c e , by a shield that is a d e q u a t e to stop all flying g l a s s
if collapse should occur.
4.
C h o o s e cork or r u b b e r s t o p p e r s used in v a c u u m s e r v i c e c a r e f u l l y .
They must be of such size that they will not be drawn through the opening which
they are intended to close.
5.
to disassemble
equipment.
6.
Do not s t o p p e r h o t flasks c o n t a i n i n g u n c o n d e n s e d v a p o u r s or
To do so will subject them to vacuum on cooling.
41
steam.
Equipment
Handling
1.
W h e n using a m a n u a l cork b o r e r , do not hold the s t o p p e r in the p a l m
of the hand.
Place the stopper large end down on a soft, flat surface and hold
in p l a c e w i t h the t h u m b and f o r e f i n g e r .
K e e p the b o r e r sharp and l u b r i c a t e
with water or glycerine to prevent binding. Do not force the borer through the
stopper but twist to cut the material.
Use stout gloves for added protection
in case of slippage.
2.
Do
not lift the cover of a c e n t r i f u g e until r o t a t i o n has
Keep the cover closed when the centrifuge is not in use.
stopped.
3.
C y l i n d e r s c o n t a i n i n g i n d u s t r i a l gases must be properly anchored by
chains or heavy straps or held in stands.
Reactive gases should be stored away
from each other (e.g. do not store a c e t y l e n e near oxygen).
Gas s u p p l i e s for
gas liquid chromatography and atomic absorption spectroscopy are best kept on
the other side of the wall from the instrument and connected via a small duct
in the w a l l .
C y l i n d e r s t o r a g e p o i n t s s h o u l d be p r o t e c t e d from the w e a t h e r ,
p a r t i c u l a r l y in dusty areas w h e r e grit can get into the c y l i n d e r v a l v e , but
they s h o u l d be s u f f i c i e n t l y w e l l - v e n t i l a t e d to p r e v e n t l e a k i n g gas f r o m
reaching dangerous levels.
4.
Flexible tubing attached to gas supplies must be wired on or held by
clips and must be able to withstand any likely pressure.
The sudden bursting
or b l o w i n g off of a piece of tubing is s t a r t l i n g and m a y c a u s e an a c c i d e n t if
someone nearby is carrying out a hazardous operation.
5.
A rapid decrease of cooling water due to a fall in mains pressure or
a cut in the supply can damage equipment such as a still and also be hazardous.
A c o n s t a n t head d e v i c e in a t r a n s p a r e n t c o n t a i n e r w i l l give s o m e w a r n i n g of
this. However, if water pressure fluctuations are a frequent problem, a header
tank in the roof of the building may be advisable. Electrical equipment can be
fitted with automatic cutouts that turn off the electricity supply in case of
water failure.
6.7
Equipment
emergency
Safety Equipment
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Rubber aprons.
Eye goggles.
Face shields..
Disposable plastic or rubber gloves.
Bench shields (portable, clear plastic).
Pipetting bulbs.
Heavy rubber carriers for acid and alkali bottles.
Metal safety cans for flammable solvents.
M e t a l solvent s t o r a g e c a b i n e t s (about 45 g a l l o n
storage of solvents used daily in the laboratory).
Respirator filter masks (for dust or fumes).
42
capacity).
(For
Emergency
1.
2.
3.
4.
5.
6.
Equipment
A major item of emergency equipment not included in the above list is the
aid cabinet.
This is discussed in detail in Section 6.8.
first
6.8
First
Aid
First aid by definition is that initial assistance given to lessen the effect
of injury.
If the injury is sufficiently minor, then first aid will probably
s u f f i c e for t r e a t m e n t .
H o w e v e r , for s e r i o u s and e v e n m o d e r a t e l y s e r i o u s
i n j u r i e s , m e d i c a l h e l p m u s t be g i v e n as soon as p o s s i b l e .
Any first aid
m e a s u r e s w o u l d be only to give t e m p o r a r y h e l p u n t i l m e d i c a l t r e a t m e n t is
available.
S o m e o n e on the l a b o r a t o r y s t a f f s h o u l d be t r a i n e d in f i r s t - a i d ,
particularly in giving artificial respiration techniques.
Some chemicals such
as c y a n i d e are q u i c k - a c t i n g and there is r a r e l y t i m e to w a i t for a d o c t o r to
arrive, or transfer the patient to the hospital.
T h o u g h t s h o u l d be g i v e n to the l o c a l h a z a r d s that m i g h t be e x p e c t e d and the
c o n t e n t s of a first aid c a b i n e t d e s i g n e d to m a t c h .
The c a b i n e t should be
l o c a t e d in the l a b o r a t o r y p r o p e r and be a c c e s s i b l e .
A first-aid cabinet
suitable for a laboratory of 10-50 employees could contain the following:
1.
2.
A s u f f i c i e n t n u m b e r (not l e s s
unmedicated dressings for injured fingers.
than
12)
treatment.
of
small
sterilized
3.
A s u f f i c i e n t n u m b e r (not less than 6 ) of m e d i u m - s i z e d
unmedicated dressings for injured hands or feet.
sterilized
4.
A sufficient number (not less than 6) of large sterilized
dressings for other injured parts.
unmedicated
5.
A sufficient number (not less than 24) of adhesive wound
an approved type and of assorted sizes.
6.
A s u f f i c i e n t n u m b e r (not less than 4 ) of
unbleached calico, the longest size of which measures
and each of the other sides not less than 36 inches.
7.
small
8.
A sufficient
packets.
supply
t r i a n g u l a r b a n d a g e s of
not less than 51 inches
plaster.
of a b s o r b e n t
43
dressings of
sterilized
cotton
in
individual
9.
approved
10. A sufficient n u m b e r
separate sealed packets.
(not
less
eye o i n t m e n t
than 4 ) of
11.
12.
Safety pins.
13.
A tube of antiseptic
in a container
sterilized
of an
eye-pads
in
cream.
A tablespoon.
Bottle of Epsom salts (magnesium sulphate).
Bottle of milk of magnesia (dose - two tablespoonfuls).
Bottle of 1 percent acetic acid.
Hydrogen cyanide, soluble cyanides and nitriles which hydrolyse readily to HCN
when inhaled or ingested may call for treatment with capsules (0.3 ml) of amyl
nitrite w h i c h are easily crushed in a cloth from w h i c h the vapour can be
inhaled.
The following antidote for cyanide ingestion casualties consists of
two solutions which should be made up and left ready for immediate use:
S o l u t i o n A:
158 g ferrous sulphate crystals and 3 g citric acid crystals
in a litre of cold distilled w a t e r (the solution m u s t be inspected regularly
and be replaced if any deterioration has occurred).
S o l u t i o n B:
distilled water.
60 g anhydrous
sodium
carbonate
dissolved
in a litre
of
44
used.
This is described in "First Aid" (2nd E d i t i o n 1965) published by St.
John A m b u l a n c e A s s o c i a t i o n , The St. A n d r e w A m b u l a n c e A s s o c i a t i o n and the
British Red Cross Society, as well as in standard medical texts.
Bromine, formic acid, hydrofluoric acid and other acid burns on the skin can be
treated with magnesia/glycerol paste prepared by triturating 200 g magnesium
oxide with 240 ml glycerol, the paste being applied liberally over the affected
areas. Dilute ammonia (1 volume ammonia added to 15 volumes of water) has also
been found e f f e c t i v e in reducing the degree of b u r n i n g w i t h b r o m i n e , formic
acid and hydrofluoric acid.
The laboratory should have at least one book (preferably more) on first aid and
laboratory safety.
There are m a n y such available.
Some of the better ones
are :
1.
2.
3.
4.
5.
6.
Medical
1973 .
Muir.
Company,
Institute
of
Fire
in the
Chemical
in Laboratories",
MRC, U.K.
7.
Aromatic
8.
Reference Book of P r o t e c t i v e
Association, London, 1981-82.
Research
Council, "Safety
Precautions
45
7.1
(QA)
Introduction
A laboratory engaged in food control analysis must have some means of assuring
that their analytical results are of the highest quality.
Errors in analysis
can o f t e n m e a n s e r i o u s e c o n o m i c l o s s e s for the food i n d u s t r y or i m p o r t e r , as
well as possible illness or injury to the consuming public.
This assurance of
quality is not limited to confirming that a food found to be unacceptable, is
in fact b a d .
It is e q u a l l y i m p o r t a n t to a s s u r e that f o o d s f o u n d to b e
a c c e p t a b l e , are in fact good.
To do this r e q u i r e s an u n d e r s t a n d i n g and
c o m m i t m e n t by the laboratory m a n a g e m e n t as well as the operating staff, that
high quality in analysis is the foremost objective.
O f t e n , the t e r m s " Q u a l i t y C o n t r o l " and " Q u a l i t y A s s u r a n c e " are used
interchangeably when discussing analytical quality.
H o w e v e r , G a r f i e l d (1)
m a k e s a d i s t i n c t i o n b e t w e e n the t w o .
He d e f i n e s Q u a l i t y c o n t r o l a s , "...a
p l a n n e d s y s t e m of a c t i v i t i e s w h o s e p u r p o s e is to p r o v i d e a q u a l i t y p r o d u c t . "
Conversely, he defines Quality Assurance as, "...a planned system of activities
w h o s e p u r p o s e is to p r o v i d e a s s u r a n c e that the q u a l i t y c o n t r o l p r o g r a m is
actually effective."
Therefore, Quality Control encompasses all of the myriad
r e v i e w , checking and operational procedures routinely used by the laboratory to
m a i n t a i n high analytical quality.
( M a n y of t h e s e are d i s c u s s e d in the
preceeding Chapters 4 and 5.) The following discussions of Quality Assurance
u s e s G a r f i e l d ' s d e f i n i t i o n and c o v e r s t h o s e p r o c e d u r e s u s e d to c o n f i r m t h a t
high quality is being maintained.
7.2
Establishing
a QA
Programme
The acceptable
quality
for a given
2.
3.
A system of documentation
4.
Appropriate
laboratory
function.
quality.
to record
reviews.
found.
The first step is to decide the functions that should have formal review.
Some
s u g g e s t i o n s a r e s t a n d a r d s s t o r a g e and h a n d l i n g , p r e p a r a t i o n of a n a l y s i s
r e p o r t s , i n s t r u m e n t m a i n t e n a n c e and l a b o r a t o r y s a f e t y .
T h e l a b o r a t o r y Head
should carefully examine the entire laboratory operation, by audit review if
n e c e s s a r y , and s e l e c t those f u n c t i o n s w h i c h need i m p r o v e m e n t or w h i c h w o u l d
benefit from periodic monitoring.
A QA p r o g r a m m e should be d y n a m i c and subject
to change when needed. Therefore a detailed QA review could be conducted until
it is felt that the function under review will continue to operate smoothly, at
w h i c h t i m e the r e v i e w could be l e s s e n e d and a n o t h e r f u n c t i o n g i v e n i n - d e p t h
coverage .
T h e r e v i e w i t s e l f is n o r m a l l y l i m i t e d to the c r i t i c a l p a r t s of the f u n c t i o n
under review.
For e x a m p l e , a r e v i e w of s t a n d a r d s t o r a g e and h a n d l i n g c o u l d
include: accounting for all standards by inventory and checking proper storage;
c h e c k i n g t h a t no s t a n d a r d h a s e x c e e d e d its e x p i r a t i o n or d i s p o s a l d a t e ; and
visual,
p h y s i c a l a n d / o r c h e m i c a l c h e c k s to i n d i c a t e
s t a n d a r d s are not
contaminated or decomposed.
46
1.
The laboratory shall operate an internal quality assurance p r o g r a m m e
a p p r o p r i a t e to the t y p e , r a n g e and v o l u m e of w o r k p e r f o r m e d .
The quality
assurance p r o g r a m m e shall be documented in a quality manual which is available
for u s e b y the l a b o r a t o r y s t a f f .
T h e q u a l i t y m a n u a l s h a l l be m a i n t a i n e d
relevant and current by a responsible m e m b e r of the laboratory staff. A person
or persons having responsibility for q u a l i t y a s s u r a n c e w i t h i n the l a b o r a t o r y
shall be designated by the laboratory m a n a g e m e n t and have direct access to top
management.
2.
shall contain
information
regarding:
a.
(organizational
charts);
b.
c.
d.
Quality assurance
appropriate ;
e.
Where
appropriate,
m a t e r i a l , etc.;
f.
S a t i s f a c t o r y a r r a n g e m e n t s for f e e d b a c k and c o r r e c t i v e
whenever testing discrepancies are detected;
g.
Procedure
procedures;
procedures
proficiency
specific
testing,
for
use
each
of
test,
as
reference
action
complaints.
3.
The quality system shall be systematically and periodically reviewed
by or on b e h a l f of m a n a g e m e n t to e n s u r e the c o n t i n u e d e f f e c t i v e n e s s of the
arrangements, and corrective action initiated.
Such reviews shall be recorded
together with details of any corrective action taken.
47
DEFINITIONS
Quality Manual
Quality System
Terminology
Testing Laboratory
Test Method
Test Report
ENVIRONMENT
External
Internal
Controls
Controls
E Q U I P M E N T , TESTING AND
MEASURING
Calibration
Identification
Inter laboratory Correlation
P r i o r to U s e
Programmes
U s e of I n - S e r v i c e T e s t E q u i p m e n t
U s e of R e f e r e n c e S t a n d a r d s
External
In-house
O v e r l o a d e d or M i s h a n d l e d
Periodic Maintenance
P u r c h a s i n g and A c c e p t a n c e P r o c e d u r e s
Records
LABORATORY DESCRIPTION
Confidential Information
Employee Responsibility
F i e l d s of A c t i v i t y
Identification
Minimizing Improper Influence
Organizational Structure
Proprietary Rights
Technical Management Personnel
QUALITY MANAGEMENT SYSTEM
Corrective Action
F i e l d s of T e s t i n g A c t i v i t i e s
Obj ec t i v e
P r o f i c i e n c y and I n t e r l a b o r a t o r y C o m p a r i s o n T e s t i n g
Quality Assurance Management
Q u a l i t y M a n u a l - R e v i s i o n and D i s t r i b u t i o n
Quality Policy
Quality System Audit
R e s p o n s i b i l i t y for Q u a l i t y A s s u r a n c e S y s t e m
Reference Materials
Resources Employed
Scope
S u b c o n t r a c ting
Technical Complaints
U p d a t i n g and C o n t r o l of D o c u m e n t s
U s e of E x t e r n a l F a c i l i t i e s
RECORDS
C o n f i d e n t i a l i t y and S e c u r i t y
H i s t o r i c a l F i l e of T e s t M e t h o d s
Maintenance
48
SAMPLES/ITEMS TO BE TESTED
P r o t e c t i o n from Damage
R e c e i p t and D i s p o s a l
Security
STAFF
Deputy Assignments
Job D e s c r i p t i o n s
P e r s o n n e l Records
S u p e r v i s ion
Other Measures
TEST METHODS AND PROCEDURES
I n d e x of Documents
S e l e c t i o n of Test Methods
Use of Non-Standard Test Methods
TEST REPORTS/TEST
Computerized
Format
Revision
Verification
DOCUMENTS
Date
of
Dsta
T h e a b o v e i l l u s t r a t e s h o w c o m p l e x and t h o r o u g h the d o c u m e n t a t i o n f o r a QA
programme can b e .
O b v i o u s l y , not a l l l a b o r a t o r i e s w i l l need such c o m p l e t e n e s s .
H o w e v e r , t h e r e i s a m i n i m u m QA p r o g r a m m e w h i c h s h o u l d be d o n e e v e n in the
s m a l l e s t of food c o n t r o l l a b o r a t o r i e s .
T h i s should i n c l u d e the four key a r e a s
where q u a l i t y c h e c k i n g is needed most.
These are r e f e r e n c e standard m a t e r i a l
used in a n a l y s i s ,
laboratory measuring instruments,
a n a l y s i s r e p o r t s and the
t e c h n i c a l p r o f i c i e n c y of the a n a l y t i c a l s t a f f .
The l a t t e r can be r e v i e w e d in
p a r t by use of a c h e c k s a m p l e a n a l y s i s p r o g r a m m e .
T h e s e f o u r QA c h e c k a r e a s
a r e d i s c u s s e d in d e t a i l in s u c c e e d i n g S e c t i o n s 7 . 3 to 7 . 6 .
O t h e r r e l a t e d QA
a c t i v i t i e s are d i s c u s s e d under S e c t i o n 7 . 7 .
7.3
QA of R e f e r e n c e
Standards
F o r p u r p o s e s of t h i s S e c t i o n , a " R e f e r e n c e S t a n d a r d " i s a p u r e c h e m i c a l or
b i o l o g i c a l s u b s t a n c e w h i c h may be used for c o m p a r i s o n d u r i n g the q u a n t i t a t i v e
a n d / o r q u a l i t a t i v e a n a l y s i s of a c o n s t i t u e n t or a t t r i b u t e of a f o o d .
Of
c o u r s e , " p u r e " is a r e l a t i v e term.
Some m e t a l e l e m e n t s c a n be r o u t i n e l y
o b t a i n e d in 9 9 . 9 9 9 % p u r i t y , w h i l e many o r g a n i c s u b s t a n c e s would be c o n s i d e r e d
" p u r e " at 9 5 % .
The a n a l y s t m u s t j u d g e i f t h e r e f e r e n c e s t a n d a r d u s e d i s
s u f f i c i e n t l y pure for a n a l y s i s p u r p o s e s .
R e f e r e n c e s t a n d a r d s can be d i v i d e d
i n t o three g r o u p s :
1.
Primary:
These are m a t e r i a l s which have been a n a l y z e d and
c e r t i f i e d by a n a t i o n a l s t a n d a r d s o r g a n i z a t i o n or o t h e r a c c e p t a b l e
organization.
2.
Secondary:
S u b s t a n c e s whose p u r i t y is
commercial s u p p l i e r s or o r g a n i z a t i o n s o t h e r than the
certified
above.
by
the p u r i t y
certifying
analysis
by
3.
Other:
This i n c l u d e s a l l r e f e r e n c e s t a n d a r d s w h i c h are c o n s i d e r e d
a c c e p t a b l e by t h e u s e r , b u t w h i c h do n o t f a l l i n t h e a b o v e t w o g r o u p i n g s .
T h e s e can i n c l u d e l o c a l l y o b t a i n e d m a t e r i a l s w h i c h h a v e u n d e r g o n e r e p l i c a t e
a n a l y s i s and have been compared to p r i m a r y or s e c o n d a r y r e f e r e n c e s t a n d a r d s , to
calculate purity.
49
Reference
Standards
for p r i m a r y
Source
Number
Alcohols
21
Alkenes
21
Antibiotics
(Chlortetracycline
HC1)
(Erythromycin)
15
(Monensin
14
Sodium)
(Oxytetracycline
(Penicillin
Base)
"G" P r o c a i n e )
(Streptomycin
Sulfate)
(Tylosin)
Atomic
Absorption
Bacterial
Blood
(Metals)
Reference
12
11
12
14
22
Cultures
1, 2 , 3, 4
Group/Typing
Chemicals, Industrial
1 9 , 3 2 , 38
13
1 0 , 34
(Animal)
1 8 , 2 5 , 31
(U.S. Schedules
I, II)
1 6 , 1 7 , 18
(U.S. Schedules
18
Ethanol, Absolute
37
Fibers, Synthetic
21
Fuels, Motor
35
Lead
(Alcoholic Beverages)
34
(Blood)
20
(Motor Fuels)
22
50
or
Reference
Standards
Source
Htmber
23, 30, 36
23
(Sludge)
34
17,
Mycotoxins
Pesticides
Phenylalanine (PKU)
3, 4
1, 3
1, 5
27, 28
(Known Meats)
29
36
Streptococcus
19
Trichinosis
Tuleremia
1, 6, 7
Wine (Reference)
23
2.
3.
Difco Laboratories
P.O. Box 1058
Detroit, MI 48232
4.
5.
Fisher Scientific
7633 Hull Street Road
Suite 2000D
Richmond, VA 23235
6.
M A Bioproducts
Briggs Ford Road
Building 100
Walkersville, MD 21793
51
7.
8.
Wellcome Diagnostics
Research Triangle Park
North Carolina 27709
9.
American Dade
P.O. Box 520672
Miami, FL 33152
10
11
12
Pfizer Laboratories
235 E. 42nd Street
New York, NY 10017
13
Lederle Laboratories
Division of American Cyanamid
One Cyanamid Plaza
Wayne, NJ 07470
14
15
16
17
Applied Science
P.O. Box 440
State College, PA 16801
18
19
20,
E. S. A. Inc.
45 Wiggins Avenue
Bedford, MA 01730
21,
Supelco Inc.
Supelco Park
Bellefonte , PA 16823
22,
Division
52
(US-DEA)
23.
24.
25.
26.
Eureka
215 - 26th Street
Sacramento, CA 95816
27.
Admin.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
53
Services
(MD-8)
38.
Chem Service
P.O. Box 194
West Chester, PA
19380
Once a stock of appropriate reference standards has been obtained, they must be
recorded, used and stored properly.
A records book or file cards can be used,
with the following information noted for each standard:
1.
2.
Source
3.
4.
Purity.
5.
Expiration date
(if any).
6.
Special
storage
requirements.
7.
Storage
location.
(from where
received.
obtained).
for?
the
Quality
Assurance
checking
2.
Storage
(is
If not, w h y ? )
3.
review?
place,
the
storage proper?
standards
Physical Condition
( W h e r e w a s the s t a n d a r d at the
Any physical evidence of deterioration or m i s h a n d l i n g ? )
accounted
time
of
the
The t i m i n g of the r e v i e w w o u l d d e p e n d on n e e d .
An i n i t i a l c y c l e of t h r e e
m o n t h s is s u g g e s t e d .
T h i s c a n b e i n c r e a s e d or d e c r e a s e d as c o n d i t i o n s and
review results dictate.
54
7.4
QA of
Instruments
Analytical
1.
and
schedule
for
some
general
Balances
Sensitivity
(bimonthly)
2.
Calibration
(annual)
with
annual
55
cleaning
and
maintenance,
again
Spectrophotometers
1.
(ultraviolet and
Wavelength
Accuracy
visible)
(bimonthly)
2.
Photometric
Accuracy
(bimonthly)
P r e p a r e a s o l u t i o n of 60 _+ 0.25 m g p o t a s s i u m d i c h r o m a t e in o n e l i t r e
of 0.01N s u l p h u r i c a c i d .
( T h i s s o l u t i o n is q u i t e s t a b l e a n d o n c e
p r e p a r e d can be used a long time).
S c a n this s o l u t i o n f r o m 2 1 0 to
450 n m .
T h e f o l l o w i n g a b s o r b a n c e s (+ 1% f u l l s c a l e ) s h o u l d o c c u r at
the i n d i c a t e d w a v e l e n g t h s :
Wavelength
(nm)
Absorbance
235
257
313
350
0.747
0.869
0.293
0.644
A l t e r n a t i v e l y , t h e U.S. N a t i o n a l B u r e a u of S t a n d a r d s h a s a v a i l a b l e
for p u r c h a s e S R M 9 3 0 , a g l a s s f i l t e r w h i c h c a n b e u s e d s i m i l a r l y and
which has certified wavelength/absorbance values.
Spectrophotometer
1.
(infrared)
Wavelength Accuracy
(trimonthly)
Wavenumber
(cm
1.
Baseline
(atomic
+
_+
+
+
absorption)
(daily when
Absorbance
the
6
6
2
2
used)
U s i n g f l a m e o n l y , the r e c o r d e r b a s e l i n e s h o u l d
.005 a b s o r b a n c e u n i t s in a f i v e m i n u t e p e r i o d .
2.
at
Accuracy
2851
1601
1028
907
Spectrophotometer
occur
(daily when
not vary m o r e
than +
used)
T h r e e c o n s e c u t i v e a b s o r b a n c e c h e c k s of the
v a r y m o r e t h a n _+ .005 a b s o r b a n c e u n i t s .
56
same
solution
should
not
3.
Detection Limit
(monthly)
Gas
Chromatograph
1.
Column Oven
(semiannual)
2.
pyrometer.
(monthly)
C h e c k f l o w rates of all c a r r i e r
bubble meter or other device.
3.
a calibrated
Detector Response
(daily when
and
detector
gases
u s e d , using
used)
Compare present detector response with the response obtained when new
or w h e n last c l e a n e d and c a l i b r a t e d .
(in s o m e d e t e c t o r s , n o t a b l y
e l e c t r o n c a p t u r e , a d e t e r i o r a t i n g r e s p o n s e i n d i c a t e s a need for
cleaning).
1.
Chrcmatograph
used)
2.
57
7.5
QA of Analytical
Reports
1.
The work carried out by the testing laboratory shall be covered by a
report w h i c h accurately, clearly and u n a m b i g u o u s l y p r e s e n t s the t e s t r e s u l t s
and all other relevant information.
2.
shall
include at least
the following
information:
a.
b.
Unique identification of
each page of the report.
c.
d.
e.
D a t e of r e c e i p t of test
tests, as appropriate.
f.
g.
Identification
h.
Description of sampling
i.
Any d e v i a t i o n s ,
additions
specification, and any other
test .
j.
Disclosure
ut ilized.
k.
M e a s u r e m e n t s , e x a m i n a t i o n s and d e r i v e d r e s u l t s , s u p p o r t e d by
t a b l e s , g r a p h s , s k e t c h e s , p h o t o g r a p h s as a p p r o p r i a t e , and any
failure identified.
1.
A statement on measurement
m.
A s i g n a t u r e a n d t i t l e of p e r s o n ( s ) a c c e p t i n g
technical
responsibility for the test report and date of issue.
n.
A s t a t e m e n t that t h e r e p o r t s h a l l n o t be r e p r o d u c e d
full without the approval of the testing laboratory.
of
report
(such
as serial
number),
and
of
performance
of
client.
of the test
any
company.
item
and
date(s)
of
specification, method
procedure, where
and
procedure.
relevant.
non-standard
58
item.
test
uncertainty
method
(where
or
procedure
relevant).
except
in
3.
Particular care and attention shall be paid to the arrangement of the
test report, especially with regard to presentation of the test data and ease
of assimilation by the reader.
The format shall be carefully and specifically
a s s i g n e d for e a c h type of test c a r r i e d o u t , but the h e a d i n g s shall be
standardized as far as possible.
The U.S. Food and Drug A d m i n i s t r a t i o n " A n a l y s t W o r k s h e e t "
good example for purposes of discussing an analytical report
is relatively complete and includes space for all pertinent
analytical summary.
The r e v e r s e of the form w o u l d be used
and calculations as the analysis progresses.
(Figure 7.1) is a
QA programme.
It
data including an
for r a w w o r k d a t a
An a n a l y t i c a l r e p o r t QA p r o g r a m m e should i n v o l v e r e v i e w of a p r e d e t e r m i n e d
n u m b e r of c o m p l e t e d r e p o r t s on a m o n t h l y or b i m o n t h l y b a s i s .
The r e p o r t s
should be r e p r e s e n t a t i v e of the k i n d s of w o r k d o n e , w i t h a b o u t as m a n y w h i c h
s h o w law v i o l a t i o n s as are u s u a l l y e n c o u n t e r e d .
An e x a m p l e could be ten
r e p o r t s w i t h t w o b e i n g v i o l a t i v e ( a s s u m i n g the v i o l a t i o n rate is about 20%).
The object is to gain a relatively representative sampling of completed reports
in order to evaluate overall report writing.
If some section of the laboratory
has substandard reports, then their coverage can be selectively increased until
it a p p e a r s that the r e p o r t s are s a t i s f a c t o r y .
T h i s is one of the p r i m e
f u n c t i o n s of QA r e v i e w s ( w h a t e v e r the t y p e ) - to p i n p o i n t p r o b l e m areas and
give them visibility until the problem is solved.
An example of an analytical report review protocol is one which has been used
by the U.S. Food and Drug A d m i n i s t r a t i o n for QA r e v i e w of their A n a l y t i c a l
Worksheets.
Their protocol consists of a listing of performance factors that
their Worksheet (Figure 7.1) must meet, as follows:
1.
2.
Accuracy and
Completeness
a.
b.
c.
Information on the
Collection Report.
d.
T h e u s e of a p p r o p r i a t e
equipment is described.
e.
f.
If m o r e than one p e r s o n p a r t i c i p a t e d in
worksheet clearly indicates who did what.
g.
h.
i.
Any discarded
Analytical
worksheet
results are
the
sample
and
is compatible
standards,
condition
with
reagents,
the
the
and
when
integrity
Inspection
special
analysis,
the
reported.
entry
and
explained.
Methodology
The a p p r o p r i a t e m e t h o d
is used and is r e f e r e n c e d on the
worksheet.
Analyses performed and methods used are consistent
with appropriate instructions or as directed by the Supervisor.
59
ANALYST WORKSHEET
3. S E A L S
NONE
INTACT
BROKEN
1. P R O D U C T
4. D A T E
REC'D
2. S A M P L E
5. R E C E I V E D
FROM
NUMBER
6. D I S T R I C T O R L A B O R A T O R Y
7. D E S C R I P T I O N O F S A M P L E
8.
NET
CONTENTS
NOT APPLICABLE
DECLARE/UNIT
NOT DETERMINED
AMOUNT
UNITS E X A M I N E D
% OF
10. S U M M A R Y O F
11. R E S E R V E
.ORIGINAL(S)
LABELING
FOUND.
DECLARED
.COPIES
SUBMITTED
SUBMITTED
NONE
ANALYSIS
SAMPLE
1 2 . L. A N A L Y S T S I G N A T U R E (Broke
Seal
)
WORKSHEET
CHECK
14. D A T E
P R E V I O U S E D I T I O N IS O B S O L E T E .
Figure
USFDA
Analyst
60
7.1
Worksheet
REPORTED
PAGE
OF
PAGES
3.
4.
b.
Sample is analyzed so
laws or regulations.
c.
Deviations
worksheet.
d.
Supervisory
from
the
as
to
permit
referenced
used
application
method
are
of
appriopriate
explained
on
the
is validated.
Review
a.
The a n a l y s i s and m e t h o d o l o g y w a s a p p r o p r i a t e
indicated on the inspection collection report.
b.
L a b o r a t o r y c o n c l u s i o n s and final d e c i s i o n
supported by information on the worksheet.
c.
Time
Frames
a.
Sample analysis
violative,
to
are
the
problem
accurate
a confirming
analysis
and
is
Any deviations from the above which are found during the r e v i e w , are recorded
and an a t t e m p t m a d e to d e t e r m i n e h o w they o c c u r r e d .
T h e r e v i e w e r m a y find a
p a t t e r n s u c h as c e r t a i n e r r o r s a r e c o n s i s t e n t l y m a d e , i n d i c a t i n g a n e e d for
specific training.
A l l f o l l o w - u p a c t i v i t i e s and a c t i o n s t a k e n to c o r r e c t
p r o b l e m s , m u s t be detailed and documented to provide laboratory m a n a g e m e n t with
a continuing basis to evaluate improvement.
7.6
Check Sampl
Examination
O n e of the m o s t c o m m o n w a y s to e v a l u a t e o v e r a l l i n d i v i d u a l or l a b o r a t o r y
p e r f o r m a n c e in a g i v e n a n a l y s i s , is b y u s e of k n o w n c h e c k s a m p l e s .
This
i n c l u d e s b o t h i n t r a ( w i t h i n ) the l a b o r a t o r y and i n t e r ( b e t w e e n ) like
laboratories.
The A m e r i c a n Chemical Society (ACS) in their 1980 Guidelines for
Data Quality Evaluation, stated:
"At the o u t s e t , a l a b o r a t o r y s h o u l d d e m o n s t r a t e its p r o f i c i e n c y u s i n g
prototype and non-critical samples, thereby reducing the probability that bad
d a t a w i l l be g e n e r a t e d on c r i t i c a l s a m p l e s , e s p e c i a l l y t h o s e i n v o l v i n g
complicated unknown mixtures.
An i n t r a l a b o r a t o r y q u a l i t y c o n t r o l p r o g r a m
s h o u l d i n c l u d e the use of b l i n d s a m p l e s in a d d i t i o n to c h e c k s a m p l e s w h o s e
v a l u e s are k n o w n to the a n a l y s t s .
A l l a n a l y s t s s h o u l d be m o n i t o r e d b y the
quality control procedures, and any assessment of laboratory performance should
include all of the analysts involved, or at least a random selection of those
analysts.
I n t e r l a b o r a t o r y Q u a l i t y A s s u r a n c e p r o g r a m s s h o u l d also use b l i n d
s a m p l e s in a d d i t i o n to c h e c k s a m p l e s ,
in o r d e r to p r o v i d e a r e a l i s t i c
assessment of the performance of the method that is achievable in the field."
L a t e r , in 1 9 8 2 , the A C S m a d e an a d d i t i o n a l s t a t e m e n t
reliability and acceptability of analysis data:
regarding
improving
61
factors
influencing
final
DATA
Figure 7.2
During 1984, the U.S. Association of Food and Drug Officials (AFDO) assembled a
listing of proficiency and check sample programs available through various U.S.
a g e n c i e s and o r g a n i z a t i o n s .
The listing is as f o l l o w s , giving c h e c k s a m p l e
type, the product involved and the check sample program sponsor:
Program
Sponsor
Product(s)
Aflatoxins
Milk, Corn
Alcohol
Blood
Antibiotics
Meat
Antibiotics
Milk
Arsenic
Meat, Poultry
Filters
Asbestos
(Number of Fibres)
Bacteriology
Milk, General
Bioassay of Antibiotics
Feed s
Cations
Water
Cereal
Water
Cereal
Components
Coliforms
62
Food
6,7
Drinking Water,
Fatty
Prograai
Sponsor
Product(s)
Water
Fats and
Acids
Oils
Fertilizers
Frtilizers
13
Fibre
Fibre
11
Flammables
Various
11
Fluoride
Water
Food
Various
Characterization
Components
Herbicides and
Industrial
Lead and
Chemicals
FEP
Medicated
Metals
Organics
Feeds
(Cations)
Metals and
Foods
Urine and
17
Water
10
Fish
Blood
Feed s
Food
Water
Minerals
Microb iology
Microscopic
14
Various
Characterization
Products
18,19
Feed s
15
Mould s
Mycology
Organic
Chemicals
Water
Organic
Solvents
Charcoal
Organics
Semi-Volatile
Organochlorine
Tube
Synthetic
Compounds
14
Organics
Leachate
12
Plasma
10
Fat, Blood
Meats,
Poultry
Phosphatase
Milk
Protein/Moisture/Fat/Salt
Meat
Residues,
Meats,
Pesticide
Poultry
Pesticides/Herbicides
Water
Pesticides/Herbicides
Vegetables,
Smalley Oil
Feed s
Milk
Somatic
Cell
Meals
Count
and Drinking
Sulfonamide s
Meats,
Vitamins
Milk, Feed,
Waste Water
Parameters
Water
63
Foods
Poultry
Foods
Water
9,10,14
6,16
4
1
9
The U . S . s p o n s o r s
1.
A m e r i c a n A s s o c i a t i o n of C e r e a l
3340 P i l o t K n o b Road
St. P a u l , MN 55121
2.
A m e r i c a n Oil C h e m i s t s Society
508 South Sixth Street
C h a m p a i g n , IL 61820
3.
U . S . D e p a r t m e n t of T r a n s p o r t a t i o n
Transportation Systems Center, Kendall
Cambridge, MA 02142
are
Chemists
Square
4.
U . S . D e p a r t m e n t of A g r i c u l t u r e , FSIS
P . O . Box 5080
S t . L o u i s , MO 63115
5.
N a t i o n a l I n s t i t u t e of O c c u p a t i o n a l Safety and H e a l t h
C h e m i c a l R e f e r e n c e L a b o r a t o r y (PAT) (R-3)
4676 C o l o m b i a P a r k w a y
C i n c i n n a t i , OH 4 5 2 2 6
6.
U . S . Food and D r u g A d m i n i s t r a t i o n
1090 T u s c u l u m A v e n u e
C i n c i n n a t i , OH 4 5 2 2 6
7.
U . S . C e n t e r for D i s e a s e C o n t r o l
Chief, Performance Evaluation Branch, Laboratory
P r o g r a m O f f i c e , A t l a n t a , GA 3 0 3 3 3
Telephone: (404) 329-3847
8.
A m e r i c a n A s s o c i a t i o n of Feed C o n t r o l
c/o L a w and C o m p a n y
P . O . B o x 1558
A t l a n t a , GA 30301
9.
U . S . Environmental Protection
QA B r a n c h , EMSL
C i n c i n n a t i , OH 4 5 2 6 8
10.
U . S . E n v i r o n m e n t a l P r o t e c t i o n A g e n c y , QA D i v i s i o n
E M S L , P . O . Box 15027
Las V e g a s , NV 89114
T e l e p h o n e : (702) 7 9 8 - 2 1 0 0
11.
12.
A m e r i c a n S o c i e t y for Testing
1916 R a c e S t r e e t
P h i l a d e l p h i a , PA 19103
13.
A s s o c i a t i o n of A m e r i c a n Plant Food C o n t r o l O f f i c i a l s
c/o W . Penn Z e n t m e y e r
V A D e p a r t m e n t of A g r i c u l t u r e and C o n s u m e r S e r v i c e s
P . O . Box 1163
R i c h m o n d , VA 23201
Telephone: (804) 786-3511
Officials
Agency
Material
64
14.
15.
16.
17.
18.
19.
Microscopists
It is a d v i s a b l e to p a r t i c i p a t e in as m a n y i n t e r - 1 a b o r a t o r y c h e c k s a m p l e
p r o g r a m s as are a v a i l a b l e in the a r e a s of i n t e r e s t to the l a b o r a t o r y .
The
s p o n s o r i n g o r g a n i z a t i o n s u s u a l l y p r o v i d e a s u m m a r y r e p o r t to p a r t i c p a t i n g
l a b o r a t o r i e s , w h i c h g i v e s an e v a l u a t i o n of the l a b o r a t o r y ' s p e r f o r m a n c e as
compared
to o t h e r p a r t i c i p a n t s .
T h e i n t e r - 1 a b o r a t o r y p r o g r a m can be
supplemented by an intra program to highlight specific areas of concern which
W h e n s e l e c t i n g s a m p l e s for an
are n o t c o v e r e d in the inter p a r t i c i p a t i o n .
intra program, the following considerations should be taken into account:
1.
The capability
laboratory.
to analyze
the
2.
3.
4.
is generally
in the
employed.
techniques,
including
in cost.
A l w a y s keep in mind that the evaluation of check sample results must include
all aspects of the analysis.
In cases where there is a large discrepancy from
the expected or true result, the laboratory must investigate all aspects of the
analysis (as given in Figure 7.2) to d e t e r m i n e w h a t specific analysis area or
areas are suspect.
From this, the laboratory should take appropriate action to
prevent reoccurrence of a similar difficulty.
65
7.7
Other QA Activities
1.
S a f e t y - The laboratory safety programme can be periodically reviewed
(about every three months) to determine that safety and emergency materials are
on hand and b e i n g used. T h i s w o u l d i n c l u d e a c h e c k of any i n j u r y or a c c i d e n t
records and a review that appropriate follow-up corrective measures were taken.
2.
S u p p l y M a n a g e m e n t - R e f e r e n c e s t a n d a r d h a n d l i n g and s t o r a g e w a s
discussed earlier.
The s a m e g e n e r a l p r i n c i p l e s a p p l y to all l a b o r a t o r y
supplies, such as glassware, chemicals, solvents and others. A QA review would
focus on whether supplies are being ordered, stored and distributed properly.
3.
S a m p l e M a n a g e m e n t - The s a m p l e s r e c e i v e d by the l a b o r a t o r y for
analysis must be accounted for. This is even more critical when the laboratory
is i n v o l v e d in food l a w e n f o r c e m e n t .
An a c c o u n t a b i l i t y s y s t e m s h o u l d be
e s t a b l i s h e d and in o p e r a t i o n (see S e c t i o n s 4.2 and 4.3). The QA r e v i e w w o u l d
determine that the system is working properly and that samples are accounted
for throughout their receipt, storage, analysis and final disposition.
4.
T r a i n i n g - This m a y s e e m an odd area for QA r e v i e w , but it r a n k s in
importance to most other laboratory operations.
A QA review of training could
i n c l u d e c h e c k s of o n g o i n g f o r m a l t r a i n i n g p r o g r a m m e s for n e w a n a l y s t s and
checks of training needs and records for experienced analysts.
The importance
of t r a i n i n g c a n n o t be o v e r e m p h a s i z e d and a QA r e v i e w p r o g r a m m e o f t e n g i v e s
training needed visibility to management.
The above are only examples and laboratory management must select with care the
o p e r a t i o n a l areas n e e d e d for Q u a l i t y A s s u r a n c e r e v i e w .
R e m e m b e r that any
laboratory function can be (and often should be) subject to QA review.
7.8
Text
1.
G A R F I E L D , F.M.,
Laboratories, 2.
VA, U.S.A.
2.
3.
INTERNATIONAL LABORATORY
Report of Task Force D.
Farther
References
1985.
Q u a l i t y A s s u r a n c e P r i n c i p l e s for A n a l y t i c a l
Association of Official Analytical Chemists, Arlington,
ACCREDATION
CONFERENCE,
London.
Oct.
of
1984.
Reading
E v a l u a t i o n and
of
Standards,
66
of
D U N C A N , A.J.
1974.
Q u a l i t y C o n t r o l and I n d u s t r i a l
Richard D. Irwin, Inc., Homewood, IL., U.S.A.
Statistics,
4th
Ed.,
GRYNA,
1980.
Quality
F.M. & B I N G H A M ,
Planning
B.S.
1974.
and Analysis,
Quality
Laboratories,
McGraw-Hill.
Control
Handbook,
67
the
AOAC,
F A O T E C H N I C A L PAPERS
F A O F O O D A N D N U T R I T I O N PAPERS
1/1
1/2
Report of t h e joint F A O / W H O / U N E P c o n f e r e n c e o n
m y c o t o x i n s , 1 9 7 7 (E F S)
Report o f a j o i n t F A O / W H O expert c o n s u l t a t i o n o n
dietary f a t s and oils in h u m a n nutrition,
18 Rev. 1
Bibliography of f o o d c o n s u m p t i o n s u r v e y s ,
1 9 8 4 (E)
18 Rev. 2
Bibliography of f o o d c o n s u m p t i o n s u r v e y s ,
1 9 8 7 (E)
18 Rev. 3
Bibliography of f o o d c o n s u m p t i o n s u r v e y s ,
1 9 9 0 (E)
19
20
21
22
Legumes in h u m a n n u t r i t i o n , 1 9 8 2 (E F S)
M y c o t o x i n surveillance - a guideline, 1 9 8 2 (E)
Guidelines for agricultural t r a i n i n g curricula in
A f r i c a , 1 9 8 2 (E F)
23
M a n a g e m e n t of g r o u p f e e d i n g p r o g r a m m e s ,
1 9 8 2 (E F P S)
Food and n u t r i t i o n in t h e m a n a g e m e n t of g r o u p
feeding p r o g r a m m e s , 1 9 9 3 (E F S)
Evaluation o f n u t r i t i o n i n t e r v e n t i o n s , 1 9 8 2 (E)
JECFA s p e c i f i c a t i o n s for i d e n t i t y and p u r i t y of
b u f f e r i n g agents, salts; e m u l s i f i e r s , t h i c k e n i n g
a g e n t s , stabilizers; f l a v o u r i n g a g e n t s , f o o d
colours, s w e e t e n i n g agents and m i s c e l l a n e o u s
f o o d additives, 1 9 8 2 (E F)
Food c o m p o s i t i o n tables for t h e Near East,
1 9 7 7 (E F S)
1 9 7 8 (E)
5
5 Rev. 1
5 Rev. 2
JECFA - guide t o s p e c i f i c a t i o n s , 1 9 7 8 (E F)
JECFA - guide t o s p e c i f i c a t i o n s , 1 9 8 3 (E F)
JECFA - guide t o s p e c i f i c a t i o n s , 1 9 9 1 (E)
W o m e n in f o o d p r o d u c t i o n , f o o d handling and
n u t r i t i o n , 1 9 7 9 (E F S)
A r s e n i c and t i n in f o o d s : r e v i e w s of c o m m o n l y
u s e d m e t h o d s of analysis, 1 9 7 9 (E)
10
11
12
P r e v e n t i o n of m y c o t o x i n s , 1 9 7 9 (E F S)
The e c o n o m i c value of breast-feeding, 1 9 7 9 (E F)
JECFA s p e c i f i c a t i o n s for i d e n t i t y and purity of
f o o d c o l o u r s , f l a v o u r i n g agents and other f o o d
a d d i t i v e s , 1 9 7 9 (E F)
2 3 Rev. 1
24
25
26
27
28
1 9 8 3 (E)
Review of f o o d c o n s u m p t i o n s u r v e y s 1 9 8 1 ,
1 9 8 3 (E)
JECFA s p e c i f i c a t i o n s for i d e n t i t y and p u r i t y of
b u f f e r i n g agents, salts, e m u l s i f i e r s , stabilizers,
t h i c k e n i n g agents, e x t r a c t i o n s o l v e n t s , f l a v o u r i n g
agents, s w e e t e n i n g agents and m i s c e l l a n e o u s
f o o d additives, 1 9 8 3 (E F)
Post-harvest losses in quality of f o o d grains,
1 9 8 3 (E F)
13
Perspective o n m y c o t o x i n s , 1 9 7 9 (E F S)
14
14/1
1 4 / 1 Rev.1
14/2
A d d i t i v e s , c o n t a m i n a n t s , t e c h n i q u e s , 1 9 8 0 (E)
14/3
14/4
C o m m o d i t i e s , 1 9 7 9 (E)
M i c r o b i o l o g i c a l analysis, 1 9 7 9 (E F S)
30
F A O / W H O f o o d additives d a t a s y s t e m , 1 9 8 4 (E)
3 0 Rev. 1
14/5
14/6
1 4 / 6 Rev.1
14/7
Food
Food
Food
Food
31/1
c o n t a m i n a n t s and c o m p o s i t i o n , 1 9 8 6 (C E)
Food analysis: q u a l i t y , adulteration and t e s t s of
32
14/8
i d e n t i t y , 1 9 8 6 (E)
I n t r o d u c t i o n t o f o o d s a m p l i n g , 1 9 8 8 (Ar C E F S)
T r a i n i n g in m y c o t o x i n s analysis, 1 9 9 0 (E S)
M a n a g e m e n t of f o o d c o n t r o l p r o g r a m m e s ,
33
14/9
14/10
14/11
1 9 9 1 (E)
Q u a l i t y a s s u r a n c e in the f o o d c o n t r o l
m i c r o b i o l o g i c a l laboratory, 1 9 9 2 (E F S)
Pesticide residue analysis in t h e f o o d c o n t r o l
l a b o r a t o r y , 1 9 9 3 (E F)
Q u a l i t y assurance in t h e f o o d c o n t r o l chemical
35
R e v i e w of f o o d c o n s u m p t i o n s u r v e y s 1 9 8 5 ,
1 9 8 6 (E)
36
l a b o r a t o r y , 1 9 9 3 (E)
I m p o r t e d f o o d inspection, 1 9 9 3 (E F)
Radionuclides in f o o d , 1 9 9 4 (E)
C a r b o h y d r a t e s in h u m a n nutrition, 1 9 8 0 (E F S)
A n a l y s i s of f o o d c o n s u m p t i o n s u r v e y data for
d e v e l o p i n g c o u n t r i e s , 1 9 8 0 (E F S)
JECFA s p e c i f i c a t i o n s for i d e n t i t y and p u r i t y of
s w e e t e n i n g a g e n t s , e m u l s i f y i n g agents, f l a v o u r i n g
a g e n t s and other f o o d additives, 1 9 8 0 (E F)
Bibliography of f o o d c o n s u m p t i o n s u r v e y s ,
1 9 8 1 (E)
38
39
Quality c o n t r o l in f r u i t and v e g e t a b l e p r o c e s s i n g ,
1 9 8 8 (E F S)
D i r e c t o r y of f o o d and n u t r i t i o n i n s t i t u t i o n s in the
Near East, 1 9 8 7 (E)
Residues of s o m e v e t e r i n a r y d r u g s in animals and
f o o d s , 1 9 8 8 (E)
14/12
14/13
14/14
14/15
14/16
15
16
17
18
inspection, 1981
for e x p o r t , 1 9 7 9
for e x p o r t , 1 9 9 0
analysis: general
(Ar E) (Rev. 1 9 8 4 , E S)
(E S)
(E S)
t e c h n i q u e s , additives,
29
31/2
34
37
40
41
41/2
Residues of v e t e r i n a r y d r u g s in f o o d s ,
1 9 8 5 (E/F/S)
Nutritional implications of f o o d aid: an a n n o t a t e d
bibliography, 1 9 8 5 (E)
JECFA s p e c i f i c a t i o n s for i d e n t i t y and p u r i t y of
certain f o o d additives, 1 9 8 6 (E F)
41/3
41/4
55
56
f o o d s . T h i r t y - e i g h t h m e e t i n g of t h e joint
F A O / W H O Expert C o m m i t t e e o n Food A d d i t i v e s ,
1 9 9 1 (E)
57
58
41/5
59
60
N u t r i t i o n e d u c a t i o n for t h e public, 1 9 9 5 (E F S)
Food f o r t i f i c a t i o n : t e c h n o l o g y and quality c o n t r o l ,
1 9 9 6 (E)
41/6
f o o d s . Fortieth m e e t i n g of t h e J o i n t F A O / W H O
Expert C o m m i t t e e on Food A d d i t i v e s , 1 9 9 3 (E)
Residues of s o m e v e t e r i n a r y drugs in animals and
61
62
B i o t e c h n o l o g y and f o o d s a f e t y , 1 9 9 6 (E)
N u t r i t i o n e d u c a t i o n for t h e public - D i s c u s s i o n
papers of t h e FAO Expert C o n s u l t a t i o n , 1 9 9 6 (E)
63
64
Street f o o d s , 1 9 9 7 (E/F/S)
W o r l d w i d e regulations for m y c o t o x i n s 1 9 9 5 - A
c o m p e n d i u m , 1 9 9 7 (E)
Risk m a n a g e m e n t and f o o d s a f e t y , 1 9 9 7 (E)
f o o d s . F o r t y - s e c o n d m e e t i n g of the J o i n t
F A O / W H O Expert C o m m i t t e e on Food A d d i t i v e s ,
1 9 9 4 (E)
41/7
41/8
Residues of s o m e
f o o d s . Forty-third
Expert C o m m i t t e e
Residues of s o m e
41/9
f o o d s . F o r t y - f i f t h m e e t i n g of t h e J o i n t F A O / W H O
Expert C o m m i t t e e o n Food A d d i t i v e s , 1 9 9 6 (E)
Residues of s o m e v e t e r i n a r y drugs in animals and
f o o d s . F o r t y - s e v e n t h m e e t i n g of t h e J o i n t
F A O / W H O Expert C o m m i t t e e o n Food A d d i t i v e s ,
1 9 9 7 (E)
65
Availability: November 1 9 9 7
Ar
Arabic
C
E
F
Chinese
English
French
Multil
Multilingual
Out of print
In preparation
42
42/1
Portuguese
Spanish
43
c u l t i v a t e d plants as f o o d , 1 9 8 9 (E)
Guidelines for agricultural training curricula in A r a b
c o u n t r i e s , 1 9 8 8 (Ar)
44
R e v i e w of f o o d c o n s u m p t i o n s u r v e y s 1 9 8 8 ,
45
46
1 9 8 8 (E)
Exposure of i n f a n t s and children t o lead, 1 9 8 9 (E)
S t r e e t f o o d s , 1 9 9 0 (E/F/S)
47/1
Utilization of t r o p i c a l f o o d s : cereals, 1 9 8 9 (E F S)
47/2
47/3
47/4
47/5
1 9 8 9 (E F S)
Utilization of t r o p i c a l f o o d s : t r o p i c a l oil seeds,
1 9 8 9 (E F S)
47/6
47/7
47/8
48
N u m b e r not assigned
49
50
51
52/1
C o m p e n d i u m of f o o d additive s p e c i f i c a t i o n s V o l . 1, 1 9 9 3 (E)
C o m p e n d i u m of f o o d additive s p e c i f i c a t i o n s -
52/2
V o l . 2 , 1 9 9 3 (E)
52 Add. 1
52 Add. 2
52 Add. 3
52 Add. 4
52 Add. 5
53
54
C o m p e n d i u m of f o o d additive
A d d e n d u m 1, 1 9 9 2 (E)
C o m p e n d i u m of f o o d additive
A d d e n d u m 2, 1 9 9 3 (E)
C o m p e n d i u m of f o o d additive
A d d e n d u m 3, 1 9 9 5 (E)
C o m p e n d i u m of f o o d additive
A d d e n d u m 4 , 1 9 9 6 (E)
C o m p e n d i u m of f o o d additive s p e c i f i c a t i o n s A d d e n d u m 5, 1 9 9 7 (E)
M e a t and m e a t p r o d u c t s in h u m a n n u t r i t i o n in
d e v e l o p i n g c o u n t r i e s , 1 9 9 2 (E)
N u m b e r not assigned
through
the
authorized
Group,
- --
'
'
'
- - -
'
. .
ISBN 92-5-102489-8
9
M
.87
7 8 9 2 5 1
ISSN 0254-4725
0 2 4 8 9 8
T0432E/2/9.97/500