Vous êtes sur la page 1sur 8

Logic C22 / Logic C22S

Manuale di installazione quadro elettrico per cancelli a 1 o 2 motori 24 V=


Electric board installation handbook for 1 or 2 motors for gate 24 V=
Manuel d'installation armoire lectrique pour portails 1 ou 2 moteurs 24 V=
Montageanleitung fr Steuerung mit 1 oder 2 Motoren 24 V=
Manual de instalacin cuadro electrico para cancelas 1 o 2 motores 24 V=
Rosso
Red

BATT. 12V 6.5 Ah -

Nero
Black

BATT. 12V 6.5 Ah +

F25A

+B -B
NIO

TC

TR

RP

OPEN

LogicC22
DIP
1

ON

POWER

F2
VM

F1
L N

+
- +
36 35 34 33 32 31

M2

M1

M2

R1

SA

15 14 13 0 0 1 1 2 3 4 5 6 7 8 9 20 30

M1

IP1579 14-03-2003

NON USARE / NOT USE

Apertura parziale / Partial opening

Stop-Autoritenuta / Stop - Control hold down

Sicurezza d'inversione / Reversal safety contact

Sicurezza in chiusura / Safety while closing

Chiusura / Closing

Passo-passo / Step by step

Apertura / Opening

Sicurezza in apertura / Safety while opening

F1=F1.6 A
F2=F2.5 A

Chiusura autom. / Automatic closure

Alimentazione accessori -

Accessories power supply +

Lampada / Lamp

Lampeggiante / Flashing light

Elettroserratura / Electric lock

230 V~

Fig. 1

DITEC S.p.A.
Via Mons. Banfi, 3
21042 Caronno P.lla (VA) Italy
Tel.+39 02 963911 - Fax +39 02 9650314
www.ditec.it

ISO 9001 - Cert. n 0957/1

ENGLISH

GENERAL SAFETY PRECAUTIONS


This installation manual is intended for professionaly competent personnel only.
The installation, the power connections and the settings must be completed in conformity with Good Working
Methods and with the regulations in force.
Read the instructions carefully before beginning to install the product. Incorrect installation may be a source of
danger.
Packaging materials (plastics, polystyrene, etc) must not be allowed to litter the environment and must be kept
out of the reach of children for whom they may be a source of danger.
Before beginning the installation check that the product is in perfect condition.
Do not install the product in explosive areas and atmospheres: the presence of flammable gas or fumes represents a serious threat to safety.
The safety devices (photocells, sensitive edges, emergency stop, etc) must be installed taking into account: the
provisions and the directives in force, Good Working Methods, the installation area, the funtional logic of the
system and the forces developed by the motorised door or gate.
Before making power connections, check that the rating corresponds to that of the mains supply
A multipolar disconnection switch with a contact opening gap of at least 3 mm must be included in the
mains supply.
Check that upstream of the electrical installation an adequate residual current circuit breaker and an overcurrent
cut out are fitted.
When requested, connect the motorized door or gate to an effective earthing system carried out as indicated by
current safety regulations.
During installation, maintenance and repair operations, cut off the power supply before opening the cover to
access the electrical parts.
The electronic parts must be handled using earthed antistatic conductive arm bands.
The manufacturer of the motorisation declines all responsability in the event of components which are not
compatible with the safe and correct operation of the product.
For repairs or replacements of products only original spare parts must be used.
INSTALLATION WARNING
Secure the control panel permanently. Drill a hole into the lower side of the container so as to run the cables
through it. Secure the cables, if they are accessible, by means of appropriate gland plates (not provided by us).
Keep the line and motor conductors separate (at least 8 mm) from the control conductors at the terminal board
connection points (for example, by means of clamps). Connect the line and motor protection conductors (yellowgreen) by means of the terminal provided. Re-close the container by means of the 4 screws, taking care to
properly position the cover (lower side = devoid of gasket).

All right reserved


All data and specifications have been drawn up and checked with the greatest care. The manufacturer cannot however take any
responsibility for eventual errors, ommisions or incomplete data due to technical or illustrative purposes.
DITEC S.P.A - IP1579 - Logic C22 / Logic C22S

Logic C22

Logic C22S

230 V~ / 50 Hz
12 V 6.5 Ah
24 V= / 2x12A (max)
24 V= / 0.3 A (nominal)
24 V= / 0.5 A (peak)
-15 C / +50 C
IP54
225x320x120

230 V~ / 50 Hz
/
24 V= / 2x4.5A (max)
24 V= / 0.3 A (nominal)
24 V= / 0.5 A (peak)
-15 C / +50 C
IP54
225x320x120

TECHNICAL DATA
Power supply
Batteries
Motors output
Accessories power supply
Temperature
Degree IP
Dimensions
1.

ELECTRICAL CONNECTION

1.1 Controls
Description

2 N.O. AUTOMATIC CLOSURE

The automatic closure function is enabled by a permanent contact.

3 N.O. OPEN

It starts the opening operation.

4 N.O. CLOSE

It starts the closing operation.

5 N.O. STEP BY STEP

It starts the closing or opening operation in sequence: openstop-close-open. Warning: if the automatic closure is
enabled, the stop is not permanent but lasts for the time set
by means of TC.

6 N.C. OPENINGSAFETYCONTACT

It stops and/or prevents the opening operation.


Refer to TC setting chapter 1.3.

7 N.C. CLOSINGSAFETYCONTACT

It stops and/or prevents the closing operation.


Refer to TC setting chapter 1.3.

8 N.C. REVERSAL SAFETY


CONTACT

Reverses movement (re-opens) during closing.


When door is not moving, inhibits all operation.
Refer to TC setting chapter 1.3.

9 N.C. STOP / CONTROL HOLD


TO RUN

Control 1-9 open stops the movement and enables the


service man function.
In this condition opening (1-3 / 1-20) and closing (1-4)
controls work only if kept pressed, when released, the
automation will stop. Safeties, if present, trigger the stop
whereas the step-by-step control and the automatic closing
are disabled.
To achieve a complete stop following the opening 1-9 (for
example the emergency stop), connect the opening controls
to terminals 9-3, 9-20 and the closing controls to terminals
9-4.

EMERGENGY STOP

20 N.O. PARTIAL OPENING

30
OPEN

It causes a timer-controlled opening of the wing operated


by motor 1; opening time is set via trimmer RP.
DO NOT CONNECT - DO NOT USE

STEP BY STEP / OPEN

This is the seat for the coupling of the radio receiver. The remote
control function (open or step-by-step) is select by means of DIP1.
(OFF = 1-5; ON = 1-3).

WARNING: Link up all N.C. contacts (if not used) by means of jumpers. The terminal bearing the same
number are equivalent. The given operating and performance features can only be guaranteed with
the use of DITEC accessories and safety devices.

DITEC S.P.A - IP1579 - Logic C22 / Logic C22S

ENGLISH

Function

Control

1.2 Output and accessories


Value

ENGLISH

Output

Description

1
0

+
-

24V = / 0.3 A (nominal) Accessories power supply. Output for power external accessories
0.5 A (peak) including the gate-open signal lamp. Protected exit electronically.

14

24V = / 50 W

Flashing light (LAMPH). Is activated upon opening or closing. For preopening or pre-closing flashing see DIP2.
Protected exit with fuse F2.

15

24V = / 1.2 A

Electric lock. With the 12 V electric lock, link up the 8.2 5 W resistance in series. Protected exit with fuse F2.

13

24V = / 3 W

Gate open lamp. Turn on a light that goes off when the gate is closed.

BAT (Only for Logic C22) The electric panel is fitted with two series-connected 12V= 6.5Ah lead-acid storage
batteries. The battery is charged and kept charged only when the electric panel is powered from the mains; the
battery is used as a buffer or in case of power failure and is cut out automatically after voltage dropping to below
22V for 120 seconds.
Connect mains and battery to the electric board at least half an hour before powering the installation (in order
to charge the battery). To power off the electric board, cut off mains and disconnect the batteries.
Attention: Always ensure that the battery is connected to the electric panel. The batteries are essential for
operations in the presence of : Box 3SH, Cubic 30H, Elit 50H/BH, Luxo 5BH.
1.3 Setting and adjustments
TC

MIN=0s

MAX=120s

VM
MIN

MAX

M1 (M2)

MIN=0s

MAX=45s

MIN=3s

MAX=30s

MIN=0s

MAX=45s

TR

RP

R1

ARC BH
OBBI 3BH

MIN = 0,75A

Automatic closure time. From 0 to 120 s. Count down initiates or starts up again:
- according to the time set by TC at the end of opening or upon an open command being
given, when the gate is stationary in the open position;
- for half of the time set by TC after triggering a safety device (1-6 / 1-7 /1-8) or at the end
of partial opening.
With 1-2 or 1-9 open, automatic closing is disabled. Closing 1-2 re-enables automatic
closing. If disabled from 1-9, automatic closing is once again enabled, by contacts 1-9
being reclosed, only after an open command is given.
Movement speed adjustment. Turning of the trimmer clockwise adjusts
opening speed from a minimum to a maximum. Closing speed is about two thirds
that of opening. If Obbi3BH/Arc BH-type motors are used, the opening speed
corresponds to the closing speed.
Motor 1 (2) operating time. The opening/closing manoeuvre is schematically shown in fig.
3.3 and 3.4. The overall speed of the manoeuvre actually consists of two speeds: one set via
VM of the duration of M1 (M2) and another, a slowing down speed, lasting for a fixed interval
of 5 s during opening and 10 s during closing. Set M2 to a minimum to operate only 1 motor
or 2 motors in parallel, simultaneously controlled by M1 and wired up as shown in Fig. 5.1
(for example in the case of two motors being mounted on the same overhead door).
Delay time adjustment. Controls the delay time of motor 1 during closing from 3 to 30 seconds.
During opening, the delay of motor 2 is fixed at 3 s (only in case of M2 not being set to a
minimum). With TR set to minimum, the delay time during closing is not always 3s but only after
an opening operation completed successfully by both wings. As far as all the installations in
which wing 1 overlaps wing 2 are concerned, trimmer TR must be set to min. 1/4.
Partial opening. From 0 to 45 s. (Can in no case be set to values greater than M1).

Obstacle detection adjustment. A safety device is located on the electric panel the
purpose of which is to stop door opening and closing in case of an obstacle being detected.
With R1=MIN, maximum sensitivity to obstacles is achieved (minimum thrust).
With R1=MAX, minimum sensitivity to obstacles is achieved (maximum thrust).

MAX = 3A

R1
BOX 3SH
CUBIC 30H
ELIT 50H/BH
LUXO 5BH
MIN = 1,53A

MAX = 12A

DITEC S.P.A - IP1579 - Logic C22 / Logic C22S

10

OFF /

Description
DIP1 Radio control selector

ON /

1-5 Step by step (*)

1-3 Open

DIP2 Pre-operation warning light (fixed at Disabled during opening, and enabled Enabled both during opening
3 s)
only during automatic closing with and closing.
TC set to more than 3 seconds. (*)
DIP3 Electric lock release

Disabled (*)

NIO

Cutting of the jumper Disabled (*)


automatically activates the
system which permits motor
running
even
at
low
temperatures. To properly operate, the electric panel must be
at the same temperature as the
motors.

Electronic antifreeze system

Abled

Led POWER ALARM


Led SA

ON
Power on.
Signals that a safety contact (1-6 / 17 / 1-8 / 1-9) is open.

OFF
/
/

2. STARTING
WARNING The operations regarding point 2.3 and 2.4 are without safety devices.
The trimmer can only be adjusted with gate not moving
2.1
2.2
2.3
2.4

Make a jumper between the safety devices and the STOP.


Set TC and R1 at maximum and TR at minimum.
Make connections to motors and power supply (mains and batteries).
When slow-down microswitches are fitted, adjust them for opening and closing and set M1 and M2 to
maximum values.
Set VM and check opening and closing speeds by means of signals 1-3 and 1-4.
Warning: In case of wings slamming, adjust the microswitches so as to make them trigger sooner.
2.5 When microswitches are not fitted, set M1 (M2) and VM to mid-values.
Set speed to desired value by acting on VM and check by means of signals 1-3 and 1-4.
Note: Never send a new signal before the previous manoeuvre has been completed.
Warning: The gate may strike against the stops.
After having set the desired speed and checked it by means of signals 1-3 and 1-4, adjust the operating time M1 (M2)
so that the wings come softly at low speed against the stops.
It is advisable to set an opening slow-down time of approximately 1-2 seconds, so that in the event of friction
or adverse weather conditions (wind, ice, etc.) complete opening is assured.
Note: In order to compensate for any reduction in speed and to ensure best operating conditions it is important that the gate comes to rest against the stop before the motor comes to a halt.
2.6 Remove the jumpers, connect the safety devices and the controls and check their function.
2.7 If necessary, adjust with TR the delay time of motor 1.
2.8 If desired, connect 1-2 and adjust the automatic closure with TC. Warning: the automatic closure time
after the operation of one of the safety devices is half the set time.
2.9 Set the obstacle detection sensitivity with R1.
2.10 If desired, set the partial opening time of motor 1 via RP
2.11 Re-close the container by means of the 4 screws, taking care to properly position the cover (lower side =
Devoid of gasket).
Warning: the Logic C22/C22S control panel can recognize the type of motors connected (ARC BH BOX 3SH
CUBIC 30H ELIT 50H/BH LUXO 5BH OBBI 3BH) during the first two operations. In the event of malfunctioning,
turn the electricity off and then on again (mains and batteries, if present).

11

DITEC S.P.A - IP1579 - Logic C22 / Logic C22S

ENGLISH

(*) Factory settings.

3. EXAMPLE OF APPLICATION FOR TWO MOTORS SWING GATES

F2
F1

When Control panel LogicC22/C22S is used for swing


gates operations, the following connections can be
made:

ENGLISH

+
- +
36 35 34 33 32 31

L N

(Fig. 3.1) Wire 2 motors as specified in figure (during


opening, the +/- polarities are as shown).
With these connections, the wing shall stop on the
opening and closing mechanical stop and, if an
obstacle is detected, during the opening and closing
operation.
(Fig. 3.2) In order to prevent the wings from stopping,
bumping against the mechanical stops (for example
in case of frequently reversed operations), it is
necessary to connect 2 motors with slow-down
micro switches as shown in the figure. Triggering of
microswitches [A] and [C] causes gate to slow down
for 5 s (fig. 3.3) during opening and 10 s during closing
(fig. 3.4)

M2

Fig. 3.1

M1
F1
L N

A =

M2

max. max.
+
- +
36 35 34 33 32 31

230 V~

The following limit switch kits are available:


ELIT FC for ELIT 50H/BH
LUXO FCH for LUXO 5BH
BOX FC1 for ARC BH and BOX 3SH

M1

230 V~

A C

A C

M2

M1

Opening slowing down microswitch

C = Closing slowing down microswitch


= 1N4007

Fig. 3.2

5s
A M2

M1

5s
A

Fig. 3.3
BOX 3SH - CUBIC 30H - ELIT 50H/BH - LUXO 5BH

M2+25%
C

M1+25%
C

10 s
ARC BH - OBBI 3BH

M1

M2
C

C
10 s
Fig. 3.4

DITEC S.P.A - IP1579 - Logic C22 / Logic C22S

12

4. EXAMPLE OFAPPLICATION FOR ONE MOTOR SWING GATESAND FOR SPRING BALANCED UPAND OVER DOOR

M2

36 35 34 33 32 31

When Control panel LogicC22/C22S is used for swing


gates or balanced up-and-over doors operations, the
following connections can be made:

(Fig. 4.1) Set M2 to minimum and connect the motor


to terminals 33 and 31 of the control panel.
With these connections, the wing shall stop on the
opening and closing mechanical stop and, if an
obstacle is detected, during the opening and closing
operation.
(Fig. 4.2) Set M2 to minimum.
In order to prevent the wings from stopping, bumping
against the mechanical stops (for example in case
of frequently reversed operations), it is necessary
to connect the motor with slow-down micro switches
as shown in the figure. Triggering of microswitches
[A] and [C] causes gate to slow down for 5 s (fig.
4.3) during opening and 10 s during closing (fig. 4.4)

M1
Fig. 4.1

M1

M2

36 35 34 33 32 31 min. max.

ENGLISH

min.

M1
A =

Opening slowing down microswitch

C = Closing slowing down microswitch

The following limit switch kits are available:


ELIT FC for ELIT 50H/BH
LUXO FCH for LUXO 5BH
BOX FC1 for ARC BH and BOX 3SH

= 1N4007

Fig. 4.2
5s
A M1

Fig. 4.3
BOX 3SH
CUBIC 30H
ELIT 50H/BH
LUXO 5BH

ARC BH
OBBI 3BH
M1

M1+25%
C

C
10 s

10 s

Fig. 4.4
5. EXAMPLE OF APPLICATION FOR UP-AND-OVER DOORS WITH 2 IN-PARALLEL MOTORS

M2

36 35 34 33 32 31
Two motors can be connected in parallel (Ex. 2 BOX
motors) as shown in figure 5.1.
Slow-down micro switches can be used after the
necessary connections as shown in figure 4.2 (M1 motor
only) have been made.
13

M2

min.

M1
Fig. 5.1

DITEC S.P.A - IP1579 - Logic C22 / Logic C22S

CARONNO P.LLA - VA
QUARTO DALTINO - VE

ISO 9001
Cert. n 0957/1

DITEC S.p.A.
Via Mons. Banfi, 3
21042 Caronno P.lla (VA) Italy
Tel. +39 02 963911 - Fax +39 02 9650314
www.ditec.it