Académique Documents
Professionnel Documents
Culture Documents
SPECTROPHOTOMETER
Applications
Drinking Water
Wastewater
Power
Industrial Water
Environmental Water
Food and Beverage
Hachs most popular portable, known for its versatility and ease of use. Take your analysis where
you need it.
Specifications*
Operating Mode
Source Lamp
Tungsten
Pre-Installed Programs
50
Data Storage
500 points
Export Capability
Wavelength Range
340 to 900 nm
Wavelength Accuracy
1.5 nm
Wavelength Resolution
1 nm
Spectral Bandwidth
5 nm
Wavelength
Calibration
Wavelength Selection
Automatic: based on
selected program
Automatic: based on barcode
printed on TNTplus reagent vials
Manual: in all modes except stored
programs
Enclosure Rating
IP 41
Operating Temperature
Operating Humidity
Storage Requirements
Power Requirements
Interface
Languages
Connections
Sample Cell
Compatibility
Accessories
Dimensions
Weight
Principle of Operation
Hachs TNTplus chemistriesand
spectrophotometers are made to work
seamlessly with each other.
Many of the tests are
EPA compliant.
Over 35 tests available including
these popular EPA Approved
Parameters:
- Ammonia
- COD
- Chlorine
- Chromium
- Iron
- Nitrate
- Nitrite
- Nitrogen
- Phosphorus
- Sulfate
hach.com
Available Tests
The following table lists available tests and overall ranges for the Hach DR 2800 Portable Spectrophotometer. The ranges may
represent more than one available test for the instrument. Consult your Hach representative, Customer Service, the Hach Master
Catalog, or the Hach web site at www.hach.com for complete details of all available tests for this instrument.
TNTplus
Test
Parameter
Range
Alachlor
Alkalinity, Total
Aluminum
Ammonia, Nitrogen
Arsenic
Atrazine
TNTplus
Test
Parameter
Range
Lead
Manganese
Mercury
Methylethylketoxime (MEKO)
15 to 1000 g/L
Molybdenum, Molybdate
Nickel
Barium
2 to 100 mg/L
Nitrate, Nitrogen
0.01 to 35 mg/L
Benzotriazole
Boron
Nitrite, Nitrogen
Nitrogen, Simplified Total Kjeldahl
Bromine
Nitrogen, Total
Cadmium
Carbohydrazide
5 to 600 g/L
1 to 150 mg/L
Chloramine, Mono
Ozone
Chloride
1 to 50 ppm, threshold
Chlorine Dioxide
Phenols
Chlorine, Free
Phosphonates
Chlorine, Total
Chromium, Hexavalent
Chromium, Total
Phosphorus, Total
Cobalt
Potassium
Color
3 to 500 units
Selenium
Copper
Silica
Cyanide
Silver
Cyanuric Acd
5 to 50 mg/L
Sulfate
2 to 900 mg/L
DEHA (Diethylhydroxylamine)
3 to 450 g/L
Sulfide
5 to 800 g/L
Dissolved Oxygen
6 g/L to 40 mg/L
Surfactants, Anionic
13 to 1500 g/L
Suspended Solids
5 to 750 mg/L
Fluoride
Formaldehyde
3 to 500 g/L
Hardness, Total
(Calcium and Magnesium as CaCO3)
Tolyltriazole
Toxicity
0 to 100% Inhibition
Hydrazine
4 to 600 g/L
10 to 600 g/L
Hydroquinone
9 to 1000 g/L
Iodine
Volatile Acids
27 to 2800 mg/L
Iron, Ferrous
Zinc
Iron, Total
hach.com
Ordering Information
DR2800-01B1
Replacement Parts
LZV610
LZV583
LZV585
LZV584
LZV565
LZV642
LZV646
Light Shield
HYH019
Dust Cover
Optional Accessories
5940400
LZV537
2960100
LZV582
USB Keyboard
LZV566
LZV551
5839700
LZY274
DataTrans Software
United States:
Outside United States:
hach.com
800-227-4224 tel
970-669-3050 tel
LIT2489 Rev 4
L12 Printed in U.S.A.
Hach Company, 2012. All rights reserved.
In the interest of improving and updating its equipment,
Hach Company reserves the right to alter specifications to equipment at any time.
970-669-2932 fax
970-461-3939 fax
orders@hach.com
int@hach.com