Vous êtes sur la page 1sur 1
GE Power Systems compressor [ews Subject: Oil Pressure, Frame Group: os @ eo Date: _ Nov, 41,2000 _Series:_H302 The frame lube system has been changed on the H302 to Improve the oll pressure at lower operating speeds. The oll pump suction line from the sump has been changed from ‘2" to 34” OD tubing. Also an oil cooler with a thermostatic valve should be installed in the lube system to maintain the oil temperature within the allowable operating limits of 140° F to 170° F. Parts required are tube fittings (23-PS-7512 and SS22-PS-7511), oll cooler and 2” thermostatic valve (150° F). Frames shipped after June 1, 2000 and serial number H125 and up, will have the new pump suction line. PRESSURE CONNECT ION FOR GUAGE AND SWITCH 1 MALW BEARING I a ROSSHEAD ” 302 CRANKCASE Icrossne. t e | | suuP MAIN BEARING i = =F pS Nara ne sis ne We soit FILTER are Te Lae Tue PAK ep «vor PRovineo BY GEMINI) Gas Compressors