Vous êtes sur la page 1sur 15

- VRF Systems

1. EGPL COMPANY PROFILE


2. HISTORY
3. PRODUCTION
4. AIRSTAGE V-II PRODUCT LINE-UP
5. AIRSTAGE J-II PRODUCT LINE-UP
6. O-GENERAL DUCTABLE LINE-UP
7. DC INVERTER ROTARY VS SCROLL
8. AIRSTAGE V-II USP
9. AIRSTAGE V-II - SALIENT FEATURES
10. AIRSTAGE V-II CENTRAL CONTROLLERS

EGPL - COMPANY PROFILE


ETA General Private Limited (EGPL) is a joint venture company between ETA

- Ascon, Dubai and Fujistu General Limited, Japan.


Fujitsu General Ltd, Japan is a part of US $ 65 billion group, a Fortune
200 company. Established in year 1936.It is operating over 130 countries
worldwide.
ETA Ascon group is also one of the biggest multinational corporations with
an annual turnover of US $ 6.5 billion.
Fujitsu General Air Conditioners are one of the premium product worldwide &
known for its superior quality and reliability.
EGPL has launched General brand Air conditioners in the Indian market in
the year 2000.
EGPL has over 754 sales & service Dealers spread across the country and
operating with 4 Regional offices & 25 Branch/area offices. EGPL are
committed to provide customers with the latest world-class quality products
that conform to the International standards.
EGPL has provided solution with around 65000 HP of VRF Air-Conditioners
in the past 4 years in INDIA & 8000 HP in cosmopolitan city Mumbai,
Maharashtra and growing year on year.
EGPL Room Air Conditioning (RAC) Segment have been selling around
2 Lakh Units yearly on PAN India basis , and 48 Thousand units in Mumbai
City only.

OUR GLOBAL FOOTPRINT

AIRSTAGE V-II SERIES

AIRSTAGE V-II PRODUCT LINEUP

AIRSTAGE J-II SERIES

FUJITSU GENERAL LIMITED

AIRSTAGE J-II PRODUCT LINE-UP


OUTDOOR UNITS 4 HP, 5HP & 6 HP
IDU LINE-UP
12 Types , 52 Models , Ranging From 2.2 Kw to 14.0 Kw

Compact
Compact
Low Static
Cassette
Slim Duct
Cassette
Duct
Duct

Duct

High
Static
Pressure
Duct

Floor /
Ceiling

Ceiling

Compact Compact
Wall
Wall
Wall
Mounted
Mounted Mounted
(EEV
INTERNAL)

(EEV
EXTERNAL)

Capacity
(kW)

2.2

2.8

3.6

4.5

5.6

7.1

9.0

11.2

12.5

14.0

O-GENERAL - DUCTABLE UNITS


DuctableLineUpComprisesof1.5TR,2.0TR,3.0TR,3.75TR,5.0TR,7.5TR.
ARG25/ARG36/ARG45 2.0/3.0/3.75TR
DuctableUnit

ARG18 1.5TRDuctableUnit

ARG60/ARG90 5.0TR/7.5TR
DuctableUnit

O-General Ductable Units


ARG18A

ARG25A

ARG36A

ARG45A

ARG60A

ARG90E

AOG18

AOG25A

AOG36A

AOG45A

AOG60A

AOG90E

Tonnage

1.5

3.75

7.5

Cooling Capacity

5.4

7.1

10.5

12.7

17

25.4

Room Air Circulation (CFM)

647

647

1176

1294

1764

2528

Power Consumption (kW)

2.1

2.64

3.9

4.5

5.8

10.5

Refrigerant Type

R22

R22

R22

R22

R22

R407C

MODEL

Indoor
Outdoor

Operating Temperature (C)

52

7.5 TR
unit
R-407C

DC INVERTER TWIN ROTARY VS SCROLL


Since the VRF Technologies are derived based on the part load operations. As per the proven data , that DC twin rotary
Compressor has better efficiency when it runs at the partial load, and the Scroll compressor has the better efficiency
when it runs at the 100% full load.
This results into energy and power saving by using DC Twin rotary Inverter technologies. so these combination is best as
the maximum load will be transferred to the fixed scroll where the efficiency is much more better than the Invertor
compressor which is also a power saving. And gives stable performance with reduced friction and power consumption
hence better in longer run.

Pressure

Energy
Over
Loss
compression

DC Scroll compressor
(Inverter)
Category

Control
Motor Drive

Merit & Demerit

DC Scroll Inverter
Compressor

DC twin rotary
compressor (Inverter)
DC Twin Rotary Inverter
Compressor

Frequency Control

Variable Capacity Control


(PWM)

Reluctance DC Motor (
50HZ)

Inverter Motor ( 50Hz)

More energy consumption

Less energy consumption

Quick Operation capacity

Quick and stable operation


capacity

Low Part load Efficiency

High part load efficiency

Operating Range is narrow

Operating range is wide.

High Noise Levels

Low Noise levels

Rotary
scroll
Rotary
Scroll
Rotationalangleofrotor

AIRSTAGE V-II - USP


Compressor Deration capacity is Zero %
even at 43o C Ambient Temperature i.e.
compressor works at 100% efficiency up
to 43o C Temperature.
Non-Stop Oil Recovery operation.
Four face heat exchanger with
Hydrophilic coating & Cobalt Blue
protection.
Provision of Back-Up Operation if one
compressor fails.
Efficiently operates for cooling up to 46o
C Ambient temperature.
Wired remote control is of mini GRC
system which is capable of controlling 8
IDUS and other features.
Continuous operation during
maintenance.
Liquid back flow protection.
Advanced refrigerant control. Precision
Refrigerant flow control.
High static pressure of 80 Pa.
We recommend installation of suction
filter valve and voltage scanner relays to
protect the equipment.
Four Way piping connection.
Sub cool Heat exchanger.
Sine Wave DC INVERTER Control.

AIRSTAGE V-II - SALIENT FEATURES


HIGH EFFICIENCY OPERATION:
High EER (Energy Efficiency Ratio)

- 4.07.
COP (Co-efficient of Performance)
- 4.37.
INVERTER
DC
Twin
Rotary
Compressor with Constant DC
Scroll.
DESIGN VERSATILITY
Installation in extreme temperature
conditions is possible due to wide
operating range.
Cooling :- -15o C to 46o C
Heating :- -20o C to 21o C
High Reliability
Silent operation
Refrigerant Circulation Control.
Liquid Back Flow Protection.
EASY SERVICE AND MAINTENANCE:
Emergency stop function
Trouble diagnosis by service tool.
Auto
addressing
and
restart
function.

AIRSTAGE V-II - CENTRAL CONTROLLERS


Group Remote
Controller

Central Remote
Controller

Touch Panel
Controller

System Controller

Max. controllable
Indoor unit

100

400

1600

Max. controllable
groups

16

400

1600

Schedule

Day/week

week

year

Day/week/year

Display

2D

2D

2D

3D

Connected to
other devices

Network converter
is necessary

All in one

All in one

PC is Necessary

Wall mounted

Yes

Yes

Yes

N.A

Automatic
registration

No

Yes

Yes

Yes

Installation
Installation

Control
Control

Design

Monitor
display

14

THANKYOU!!!

Vous aimerez peut-être aussi