Vous êtes sur la page 1sur 4

Product Selector Guide

Transformer Protection Selector Guide


Features

Device

345

P642

P652

15/1

12/1

G/N/P
G/N/P

G/N/P
G/N/P

Transformer Protection

APPLICATIONS & FUNCTIONALITY

Low to Medium size LV and MV Transformers


Medium to Large size MV-HV Transformers
Auto-transformers
Non-Standard Transformers
Two windings
Three windings
More then three windings
3-phase Voltage inputs
PROTECTION & CONTROL

Transformer Differential
Maximum Number of Windings/Restraint Inputs
Harmonic Restraint
Internal Winding Standard Phase Shift Compensation
Internal Winding Non-Standard Phase Shift
Compensation
Dynamic CT Ratio-Matching
CT Mismatch Range
Restricted Ground Fault - RGF/REF
Over-excitation (Voltz Per Hertz)
Phase Undervoltage
IOC, Ground/Neutral/Phase
TOC, Ground/Neutral/Phase
Negative Phase Sequence Overcurrent
Custom programmable overcurrent curves
Overvoltage - Phase
Overvoltage - Neutral
Overvoltage - Auxiliary
Overvoltage - Negative Sequence
Current Directional, Neutral/Phase.
Voltage Transformer Fuse Failure
Current Transformer Supervision
Under/Overfrequency
Synchrocheck
Synchrophasor
Thermal Overload
Power Swing Blocking
Out of Step
Backup Distance Protection
Voltage Dependent Overcurrent (VCO/VRO)
Transformer Hottest-spot Temperature
Transformer Aging factor
Transformer Loss of Life
Lockout
Tap Changer Monitoring
Breaker Failure
Arc Flash Detection

87T

87G
24
27P
50G/N/P
51G/N/P
46
59P
59N
59X
59_2
67 N/P
VTFF/VTS
CTS
81U/O
25
49
68
78
21
51V

16/1

G/N/P
G/N/P

86

50BF

4
12
12

2
6
6

simple

32

64/32

Trip

10
Trip
18

AUTOMATION

Settings Groups
Contact Inputs (max)
Contact Outputs (max)
Non-volatile latches
Programmable Logic
FlexElements
Virtual Inputs/Outputs
Direct Inputs/Outputs
Programmable Pushbuttons
Trip/Close Coil Supervision
User-Programmable LEDs
User-Programmable Self Test
Selector Switch
Digital Counters
Digital Elements
Transducer Analog Inputs/Outputs (max)
RTD Inputs (max)

2
10
7

16

GEGridSolutions.com

4/4
10

Product Selector Guide

Features Continued

Device

345

P642

P652

MONITORING & METERING

256
32

512
24

512
16

(1)

COMMUNICATIONS INTERFACES

Front Port Local Access


Rear Communications (RS232/RS422)
Rear Communications (G.703, C37.94)
Ethernet
Fiber (Ports)
PROTOCOLS

Courier
ModBus RTU
DNP3 Serial
EGD Protocol
IEC61850
IEC 60870-5-104
IEC 60870-5-103
Simple Network Time Protocol
TCP/IP
HTTP
PRP (IEC 62439-3 Clause 4)
HSR (IEC 62439-3 Clause 5)
IRIG-B Input
Process Bus (IEC 61850-9-2)

For the most up-to-date selector guides, please visit

GEGridSolutions.com/SelectorGuides

GEGridSolutions.com

Transformer Protection

Power Factor
Current RMS
Current Phasor
Current Demand
Current - Unbalance
Voltage
Power - Apparent, Real, Reactive
MW, MVA, Mvar Demand
Breaker Arc Current
Energy
Frequency
Temperature
Current Harmonics (max)
Loss of Life Calculations
Fault Report
User Programmable Trip Reports
Event Recorder - Number of Events
Oscillography/Transient Recorder - Sampling Rate
Trip Counters
Data Logger / Trend Recording
Simulation Mode

Product Selector Guide

Transformer Protection Selector Guide


Features

Device

745

845

P643

P645

T35

T60

16/1

20/1

G/N/P
G/N/P

P/N

32/1

32/1

G/N/P
G/N/P

Transformer Protection

APPLICATIONS & FUNCTIONALITY

Low to Medium size LV and MV Transformers


Medium to Large size MV-HV Transformers
Auto-transformers
Non-Standard Transformers
Two windings
Three windings
More then three windings
3-phase Voltage inputs
PROTECTION & CONTROL

Transformer Differential
Maximum Number of Windings/Restraint Inputs
Harmonic Restraint
Internal Winding Standard Phase Shift Compensation
Internal Winding Non-Standard Phase Shift
Compensation
Dynamic CT Ratio-Matching
CT Mismatch Range
Restricted Ground Fault - RGF/REF
Over-excitation (Voltz Per Hertz)
Phase Undervoltage
IOC, Ground/Neutral/Phase
TOC, Ground/Neutral/Phase
Negative Phase Sequence Overcurrent
Custom programmable overcurrent curves
Overvoltage - Phase
Overvoltage - Neutral
Overvoltage - Auxiliary
Overvoltage - Negative Sequence
Current Directional, Neutral/Phase.
Voltage Transformer Fuse Failure
Current Transformer Supervision
Under/Overfrequency
Synchrocheck
Synchrophasor
Thermal Overload
Power Swing Blocking
Out of Step
Backup Distance Protection
Voltage Dependent Overcurrent (VCO/VRO)
Transformer Hottest-spot Temperature
Transformer Aging factor
Transformer Loss of Life
Lockout
Tap Changer Monitoring
Breaker Failure
Arc Flash Detection

87T

87G
24
27P
50G/N/P
51G/N/P
46
59P
59N
59X
59_2
67 N/P
VTFF/VTS
CTS
81U/O
25
49
68
78
21
51V

86
50BF

G/N/P
G/N/P

15/1

G/N/P
G/N/P

15/1

G/N/P
G/N/P

P/N

P/N

6
14
10

4
40
24

4
40
24

16/16

32/32

64/32

64/32

15

4/7
12

10
Trip
18

10
Trip
18

4/4
10

4/4
10

G/P

P/N

AUTOMATION

Settings Groups
Contact Inputs (max)
Contact Outputs (max)
Non-volatile latches
Programmable Logic
FlexElements
Virtual Inputs/Outputs
Direct Inputs/Outputs
Programmable Pushbuttons
Trip/Close Coil Supervision
User-Programmable LEDs
User-Programmable Self Test
Selector Switch
Digital Counters
Digital Elements
Transducer Analog Inputs/Outputs (max)
RTD Inputs (max)

4
16
8

Trip

1
1

GEGridSolutions.com

6
96
64

64/96
32/32
12
Trip/Close
48

24/12
24

6
96
64

64/96
32/32
12
Trip/Close
48

24/12
24

Product Selector Guide

Features Continued

Device

745

845

P643

P645

T35

T60

512
24

512
24

MONITORING & METERING

21

40
12

25

1024
128

1024
64

25

1024
64

(3)

(3)

COMMUNICATIONS INTERFACES

Front Port Local Access


Rear Communications (RS232/RS422)
Rear Communications (G.703, C37.94)
Ethernet
Fiber (Ports)

(2)

PROTOCOLS

Courier
ModBus RTU
DNP3 Serial
EGD Protocol
IEC61850
IEC 60870-5-104
IEC 60870-5-103
Simple Network Time Protocol
TCP/IP
HTTP
PRP (IEC 62439-3 Clause 4)
HSR (IEC 62439-3 Clause 5)
IRIG-B Input
Process Bus (IEC 61850-9-2)

For the most up-to-date selector guides, please visit

GEGridSolutions.com/SelectorGuides

GEGridSolutions.com

Transformer Protection

Power Factor
Current RMS
Current Phasor
Current Demand
Current - Unbalance
Voltage
Power - Apparent, Real, Reactive
MW, MVA, Mvar Demand
Breaker Arc Current
Energy
Frequency
Temperature
Current Harmonics (max)
Loss of Life Calculations
Fault Report
User Programmable Trip Reports
Event Recorder - Number of Events
Oscillography/Transient Recorder - Sampling Rate
Trip Counters
Data Logger / Trend Recording
Simulation Mode

Vous aimerez peut-être aussi