Vous êtes sur la page 1sur 7

EQ+X---> Max Inter Story Drift

Story

Elevation

Floor Height

Location

X-Dir Max
mm

Y-Dir Max Inter Story


mm
X-Dir Max

TOP

28.210

3.000

Top

26.495

2.914

3.315

FIF

25.210

3.150

Top

23.180

2.494

3.808

FOF

22.060

3.150

Top

19.372

2.028

4.04

THF

18.910

3.150

Top

15.332

1.569

4.065

SF

15.760

3.150

Top

11.267

1.130

3.873

FF

12.610

3.150

Top

7.394

0.966

3.445

GF

9.460

3.500

Top

3.949

1.029

2.735

B1

5.960

2.980

Top

1.214

0.170

0.882

B2

2.980

2.980

Top

0.332

0.064

0.332

Base

0.000

Drift [ in ratio]

H/
H/
H/
H/
H/
H/
H/
H/
H/

Drift , %

Result

905

0.1105% OK for LS

827

0.1209% OK for LS

780

0.1283% OK for LS

775

0.1290% OK for LS

813

0.1230% OK for LS

914

0.1094% OK for LS

1280

0.0781% OK for LS

3379

0.0296% OK for LS

8976

0.0111% OK for LS

EQ+Y---> Max Inter Story Drift


Story

Elevation

Floor Height

Location

X-Dir Max
mm

Y-Dir Max Inter Story


mm
Y-Dir Max

TOP

28.210

3.000

Top

1.802

26.816

3.352

FIF

25.210

3.150

Top

1.482

23.464

3.852

FOF

22.060

3.150

Top

1.151

19.612

4.140

THF

18.910

3.150

Top

0.844

15.472

4.202

SF

15.760

3.150

Top

0.572

11.270

4.016

FF

12.610

3.150

Top

0.346

7.254

3.549

GF

9.460

3.500

Top

0.188

3.705

2.827

B1

5.960

2.980

Top

0.240

0.878

0.595

B2

2.980

2.980

Top

0.043

0.283

0.283

Base

0.000

Drift [ in ratio]

H/
H/
H/
H/
H/
H/
H/
H/
H/

Drift , %

Result

895

0.1117% OK for LS

818

0.1223% OK for LS

761

0.1314% OK for LS

750

0.1334% OK for LS

784

0.1275% OK for LS

888

0.1127% OK for LS

1238

0.0808% OK for LS

5008

0.0200% OK for LS

10530

0.0095% OK for LS

EQ+X---> Max Inter Story Drift Check using Apr 25 Time history
Story

Elevation

Floor Height

Location

X-Dir Max
mm

Y-Dir Max Inter Story


mm
X-Dir Max

TOP

28.210

3.000

Top

26.177

26.471

3.224

FIF

25.210

3.150

Top

22.953

23.142

3.462

FOF

22.060

3.150

Top

19.491

19.549

3.714

THF

18.910

3.150

Top

15.777

15.673

3.852

SF

15.760

3.150

Top

11.925

11.656

3.811

FF

12.610

3.150

Top

8.114

7.705

3.561

GF

9.460

3.500

Top

4.553

4.084

2.858

B1

5.960

2.980

Top

1.695

1.006

1.265

B2

2.980

2.980

Top

0.430

0.347

0.43

Base

0.000

0.000

0.000

Drift [ in ratio]

H/
H/
H/
H/
H/
H/
H/
H/
H/

Drift , %

Result

931

0.1075% OK for LS

910

0.1099% OK for LS

848

0.1179% OK for LS

818

0.1223% OK for LS

827

0.1210% OK for LS

885

0.1130% OK for LS

1225

0.0817% OK for LS

2356

0.0424% OK for LS

6930

0.0144% OK for LS

EQ+Y---> Max Inter Story Drift using Apr 25 Time Hsitory


Story

Elevation

Floor Height

Location

X-Dir Max
mm

Y-Dir Max Inter Story


mm
Y-Dir Max

TOP

28.210

3.000

Top

26.177

26.471

3.329

FIF

25.210

3.150

Top

22.953

23.142

3.593

FOF

22.060

3.150

Top

19.491

19.549

3.876

THF

18.910

3.150

Top

15.777

15.673

4.017

SF

15.760

3.150

Top

11.925

11.656

3.951

FF

12.610

3.150

Top

8.114

7.705

3.621

GF

9.460

3.500

Top

4.553

4.084

3.078

B1

5.960

2.980

Top

1.695

1.006

0.659

B2

2.980

2.980

Top

0.430

0.347

0.347

Base

0.000

0.000

0.000

Drift [ in ratio]

H/
H/
H/
H/
H/
H/
H/
H/
H/

Drift , %

Result

901

0.1110% OK for LS

877

0.1141% OK for LS

813

0.1230% OK for LS

784

0.1275% OK for LS

797

0.1254% OK for LS

870

0.1150% OK for LS

1137

0.0879% OK for LS

4522

0.0221% OK for LS

8588

0.0116% OK for LS

EQ+X---> Inter Story Drift Check for Crack sections


Story

Elevation

Floor Height

Location

X-Dir Max
mm

Y-Dir Max Inter Story


mm
X-Dir Max

TOP

28.210

3.000

Top

33.782

4.435

4.470

FIF

25.210

3.150

Top

29.312

3.871

5.013

FOF

22.060

3.150

Top

24.299

3.128

5.222

THF

18.910

3.150

Top

19.077

2.403

5.185

SF

15.760

3.150

Top

13.892

1.717

4.877

FF

12.610

3.150

Top

9.015

1.096

4.282

GF

9.460

3.500

Top

4.733

1.154

3.343

B1

5.960

2.980

Top

1.390

0.304

1.022

B2

2.980

2.980

Top

0.368

0.075

0.368

Base

0.000

Drift [ in ratio] Drift , %

H/
H/
H/
H/
H/
H/
H/
H/
H/

Result

671

0.149% OK for LS

628

0.159% OK for LS

603

0.166% OK for LS

608

0.165% OK for LS

646

0.155% OK for LS

736

0.136% OK for LS

1047

0.096% OK for LS

2916

0.034% OK for LS

8098

0.012% OK for LS

EQ+Y---> Inter Story Drift Check for Crack sections


Story

Elevation

Floor Height

Location

X-Dir Max

Y-Dir Max Inter Story


mm
mm Y-Dir Max

TOP

28.210

3.000

Top

2.804

35.069

4.676

FIF

25.210

3.150

Top

2.337

30.393

5.244

FOF

22.060

3.150

Top

1.815

25.149

5.505

THF

18.910

3.150

Top

1.329

19.644

5.491

SF

15.760

3.150

Top

0.899

14.153

5.165

FF

12.610

3.150

Top

0.541

8.988

4.491

GF

9.460

3.500

Top

0.272

4.497

3.486

B1

5.960

2.980

Top

0.328

1.011

0.696

B2

2.980

2.980

Top

0.059

0.315

0.315

Base

0.000

Drift [ in ratio] Drift , %

H/
H/
H/
H/
H/
H/
H/
H/
H/

Result

642

0.156% OK for LS

601

0.166% OK for LS

572

0.175% OK for LS

574

0.174% OK for LS

610

0.164% OK for LS

701

0.143% OK for LS

1004

0.100% OK for LS

4282

0.023% OK for LS

9460

0.011% OK for LS

Note:

Crack Section used are I22=I33=0.5 for beams, I22=I33=0.7 for Columns & Walls F11=F22= 0.7
It is called that if inelastic drift is within 0.5%, the building should be within Immediate Occupancy use
If inelastic drift is within 1 ~2%, the building should be within Life safety
If inelastic drift is within 2 ~4%, the building should be within Collapse prevention

EQ+X---> Inter Story Drift Check for Crack sections using Ap25 Time History
Story

Elevation

Floor Height

Location

X-Dir Max
mm

Y-Dir Max Inter Story


mm
X-Dir Max

TOP

28.210

3.000

Top

38.782

46.089

5.271

FIF

25.210

3.150

Top

33.511

40.133

5.647

FOF

22.060

3.150

Top

27.864

33.508

5.854

THF

18.910

3.150

Top

22.010

26.537

5.835

SF

15.760

3.150

Top

16.175

19.473

5.540

FF

12.610

3.150

Top

10.635

12.662

4.933

GF

9.460

3.500

Top

5.702

6.543

3.646

B1

5.960

2.980

Top

2.056

1.533

1.595

B2

2.980

2.980

Top

0.461

0.481

0.461

Base

0.000

0.000

0.000

Drift [ in ratio] Drift , %

H/
H/
H/
H/
H/
H/
H/
H/
H/

Result

569

0.176% OK for LS

558

0.179% OK for LS

538

0.186% OK for LS

540

0.185% OK for LS

569

0.176% OK for LS

639

0.157% OK for LS

960

0.104% OK for LS

1868

0.054% OK for LS

6464

0.015% OK for LS

EQ+Y---> Inter Story Drift Check for Crack sections using Ap25 Time History
Story

Elevation

Floor Height

Location

X-Dir Max

Y-Dir Max Inter Story


mm
mm Y-Dir Max

TOP

28.210

3.000

Top

38.782

46.089

5.956

FIF

25.210

3.150

Top

33.511

40.133

6.625

FOF

22.060

3.150

Top

27.864

33.508

6.971

THF

18.910

3.150

Top

22.010

26.537

7.064

SF

15.760

3.150

Top

16.175

19.473

6.811

FF

12.610

3.150

Top

10.635

12.662

6.119

GF

9.460

3.500

Top

5.702

6.543

5.010

B1

5.960

2.980

Top

2.056

1.533

1.052

B2

2.980

2.980

Top

0.461

0.481

0.481

Base

0.000

0.000

0.000

Drift [ in ratio] Drift , %

H/
H/
H/
H/
H/
H/
H/
H/
H/

Result

504

0.199% OK for CP

475

0.210% OK for CP

452

0.221% OK for CP

446

0.224% OK for CP

462

0.216% OK for CP

515

0.194% OK for CP

699

0.143% OK for CP

2833

0.035% OK for CP

6195

0.016% OK for CP

Note:

Crack Section used are I22=I33=0.5 for beams, I22=I33=0.7 for Columns & Walls F11=F22= 0.7
It is called that if inelastic drift is within 0.5%, the building should be within Immediate Occupancy use
If inelastic drift is within 1 ~2%, the building should be within Life safety
If inelastic drift is within 2 ~4%, the building should be within Collapse prevention

EQ+X---> Inter Story Drift Check for Maximum Considered Earthquake MCE
Story

Elevation

Floor Height

Location

X-Dir Max
mm

Y-Dir Max Inter Story


mm
X-Dir Max

TOP

28.210

3.000

Top

79.659

9.051

9.963

FIF

25.210

3.150

Top

69.696

7.764

11.447

FOF

22.060

3.150

Top

58.249

6.332

12.141

THF

18.910

3.150

Top

46.108

4.919

12.217

SF

15.760

3.150

Top

33.891

3.563

11.641

FF

12.610

3.150

Top

22.250

2.812

10.361

GF

9.460

3.500

Top

11.889

3.027

8.225

B1

5.960

2.980

Top

3.664

0.504

2.664

B2

2.980

2.980

Top

1.000

0.179

1.000

Base

0.000

Drift [ in ratio] Drift , %

H/
H/
H/
H/
H/
H/
H/
H/
H/

Result

301

0.332% OK for CP

275

0.363% OK for CP

259

0.385% OK for CP

258

0.388% OK for CP

271

0.370% OK for CP

304

0.329% OK for CP

426

0.235% OK for CP

1119

0.089% OK for CP

2980

0.034% OK for CP

EQ+Y---> Inter Story Drift Check for Maximum Considered Earthquake MCE
Story

Elevation

Floor Height

Location

X-Dir Max
mm

Y-Dir Max Inter Story


mm
Y-Dir Max

TOP

28.210

3.000

Top

5.562

80.567

10.069

FIF

25.210

3.150

Top

4.580

70.498

11.562

FOF

22.060

3.150

Top

3.563

58.936

12.423

THF

18.910

3.150

Top

2.614

46.513

12.612

SF

15.760

3.150

Top

1.770

33.901

12.056

FF

12.610

3.150

Top

1.065

21.845

10.660

GF

9.460

3.500

Top

0.561

11.185

8.509

B1

5.960

2.980

Top

0.716

2.676

1.796

B2

2.980

2.980

Top

0.132

0.880

0.880

Base

0.000

Drift [ in ratio] Drift , %

H/
H/
H/
H/
H/
H/
H/
H/
H/

Result

298

0.336% OK for CP

272

0.367% OK for CP

254

0.394% OK for CP

250

0.400% Not accepted for CP

261

0.383% OK for CP

295

0.338% OK for CP

411

0.243% OK for CP

1659

0.060% OK for CP

3386

0.030% OK for CP

Note:

It is called that if inelastic drift is within 0.5%, the building should be within Immediate Occupancy use
If inelastic drift is within 1 ~2%, the building should be within Life safety
If inelastic drift is within 2 ~4%, the building should be within Collapse prevention

Not accepted for CP

EQ+X---> Inter Story Drift Check for Maximum Considered Earthquake MCE
Story

Elevation

Floor Height

Location

X-Dir Max
mm

Y-Dir Max Inter Story


mm
X-Dir Max

TOP

28.210

3.000

Top

75.584

-11.024

8.801

FIF

25.210

3.150

Top

66.783

-9.301

9.914

FOF

22.060

3.150

Top

56.869

-7.360

10.699

THF

18.910

3.150

Top

46.170

-5.234

11.158

SF

15.760

3.150

Top

35.012

-3.024

11.120

FF

12.610

3.150

Top

23.892

-1.010

10.466

GF

9.460

3.500

Top

13.426

-0.504

8.740

B1

5.960

2.980

Top

4.686

-0.059

3.417

B2

2.980

2.980

Top

1.269

-0.005

1.269

Base

0.000

0.000

0.000

Drift [ in ratio] Drift , %

H/
H/
H/
H/
H/
H/
H/
H/
H/

Result

341

0.293% OK for CP

318

0.315% OK for CP

294

0.340% OK for CP

282

0.354% OK for CP

283

0.353% OK for CP

301

0.332% OK for CP

400

0.250% OK for CP

872

0.115% OK for CP

2348

0.043% OK for CP

EQ+Y---> Inter Story Drift Check for Maximum Considered Earthquake MCE
Story

Elevation

Floor Height

Location

X-Dir Max

Y-Dir Max Inter Story


mm
mm Y-Dir Max

TOP

28.210

3.000

Top

-39.048

29.614

4.048

FIF

25.210

3.150

Top

-29.195

25.566

3.894

FOF

22.060

3.150

Top

-24.015

21.672

4.175

THF

18.910

3.150

Top

-18.591

17.497

4.361

SF

15.760

3.150

Top

-13.122

13.136

4.342

FF

12.610

3.150

Top

-7.895

8.794

4.053

GF

9.460

3.500

Top

-2.995

4.741

3.352

B1

5.960

2.980

Top

-0.778

1.389

0.945

B2

2.980

2.980

Top

-0.053

0.444

0.444

Base

0.000

0.000

0.000

Drift [ in ratio] Drift , %

H/
H/
H/
H/
H/
H/
H/
H/
H/

Result

741

0.135% OK for CP

809

0.124% OK for CP

754

0.133% OK for CP

722

0.138% OK for CP

725

0.138% OK for CP

777

0.129% OK for CP

1044

0.096% OK for CP

3153

0.032% OK for CP

6712

0.015% OK for CP

Note:

It is called that if inelastic drift is within 0.5%, the building should be within Immediate Occupancy use
If inelastic drift is within 1 ~2%, the building should be within Life safety
If inelastic drift is within 2 ~4%, the building should be within Collapse prevention

Vous aimerez peut-être aussi