ProSimulator
AMINE TREATING UNIT
AMI01
Version 3.1
Mar 2015
Sim
Infosystems
ProSimulator
Table of Contents
1.
OBJECTIVE ................................................................................................................... 3
2.
PROCESS DESCRIPTION ............................................................................................ 3
2.1 Absorber Section ....................................................................................................... 3
2.2 Turbines and Pumps Section ..................................................................................... 5
2.3 Stripper Section ......................................................................................................... 7
3. PROCESS CONTROL SYSTEM .................................................................................. 9
3.1 Flow Controllers ....................................................................................................... 9
3.2 Level Controllers .................................................................................................... 10
3.3 Pressure Controllers ................................................................................................ 10
3.4 Temperature Controller ........................................................................................... 11
4.
INTERLOCKS .............................................................................................................. 13
5.
PROCESS CONDITION SUMMARY ........................................................................ 14
6.
MALFUNCTIONS ....................................................................................................... 16
7.
STARTUP PROCEDURE ............................................................................................ 19
8.
SHUTDOWN PROCEDURE ....................................................................................... 23
9.
AMINE
TREATING UNIT-P&ID ............................................................................... 25
ProSimulator
0.06% by selective absorption using MEA (Mono Ethanol Amine). Gas handling capacity
of the simulated amine plant is 114 TPH of synthesis gas.
Amine plant consists of the following three sections :
Absorber Section
Turbine and Pumps Section
Stripper Section
MIU T QU TRNH
2.1 Mc Absorber
phn Absorber cha cc thit b sau y c th l,
Absorber Ct (T-01)
K.O Drum (D-03)
nc Solvent Cooler (E-03)
nc Solvent trao i nhit (E-02)
H thng Amin Guard cht c ch (A-01)
ProSimulator
Absorber Column
(T-01).
Absorber column is maintained at a pressure of 26 Kg/cm2 (g). Feed gas is contacted with
Lean MEA solvent cascading from Tray 3. MEA solvent
after absorbing CO
2 present in the Feed gas gets collected at the bottom drum in the
Absorber Column as Rich MEA Solvent. Heat of absorption raises the temperature of the
MEA solvent from 37.4 Deg C to 86.5 Deg C.
The top two trays of the Absorber column is Wash Section in which continuous flow of
steam condensate of 1.3 m3 /hr is maintained by using Absorber Wash Water Pump (P-01).
Steam condensate collected in the trough of Tray 2 is fed to Reflux Drum (D-02)
maintaining steam condensate level within wash section. Wash water (steam condensate)
circulation removes any solvent entrained in the product gas.
Ct Absorber (T-01). ct hp th c duy tr p sut 26 kg / cm2 (g). kh Feed c
lin lc vi nc MEA tng dung mi t Tray 3. MEA dung mi
sau khi hp th CO 2 c trong cc kh ngun cp d liu c thu thp ti trng pha di
trong
Ct Absorber nh Rich MEA dung mi. Nhit hp thu lm tng nhit ca dung mi
MEA t 37,4 C n 86,5 Deg C.
Hai khay trn cng ca ct Absorber l Ra Mc trong dng chy lin tc ngng t hi
nc l 1,3 m3 / hr c duy tr bng cch s dng Absorber Ra My bm nc (P-01).
Hi nc ngng t thu c trong mng ca Khay 2 c a n tro ngc Drum (D02) duy tr mc ngng t hi nc bn trong phn ra. Ra nc (ngng hi) lu
thng loi b dung mi bt k cun trong kh sn phm.
Knock-out Drum where traces of wash water are removed from the product
gas and temperature of Product gas is reduced if it is above design limit.
Quench water circulation is maintained in K.O Drum using Quench Water
Circulation pump (P-02).
Lean Solvent from Turbine and Pumps section transfers its sensible heat
content to the Rich Solvent leaving the bottom of the absorber in the Lean
ProSimulator
Rich solvent from the bottom of the Absorber Column after passing through Lean Solvent
Exchanger 2 (E-02) exchanger enters Flash Drum through Hydraulic Turbine and
Hydraulic Turbine Bypass Valves.
High pressure Rich solvent from Absorber column drives the Hydraulic Turbine (X2. ) as it passes through it, which in turn drives the Lean Solvent Pump (P-03B) thereby
utilizable energy of Rich Solvent is recovered. Rich solvent at the downstream of
Amine Treating Unit
5
ProSimulator
Hydraulic Turbine recombines with the Rich Solvent passing through the Hydraulic
Turbine Bypass Valves (LV101B & C) and enters into Flash Drum (D-01).
Lean Solvent from the bottom of the Stripper Column (T-02) is pumped to Absorber
Column by Lean Solvent Pumps A or S & B (P-03 A or S & B). Lean Solvent Pump A (P03A) and Lean Solvent Pump S (P-03S) are motor Driven Pumps and Lean Solvent Pump
B (P-03B) is Turbine Driven Pump (Hydraulic Turbine).
Lean Solvent Pump S (P-03S) is a standby pump which can be taken on line when P03A fails to maintain required Circulation flow.
2.2 Tuabin v Bm Mc
Phn ny bao gm cc thit b x l nh sau,
nc dung mi bm A (P-03A) - motor
nc dung mi bm S (P-03s) - motor
nc dung mi bm B (P-03B) - tuc bin thy lc Driven
thy lc Turbine (X-02)
Giu dung mi t di cng ca ct Absorber sau khi i qua nc Solvent trao i 2 (E-02)
trao i vo flash Drum qua tua bin thy lc v thy lc Turbine Van Bypass.
p lc cao Giu dung mi t ct Absorber a Turbine thy lc (X2.) khi n i qua n, m ln lt cc a vi dung mi bm nc (P-03B) nng lng do
utilizable ca Rich dung mi thu hi. dung mi giu h lu
Turbine thy lc ti kt hp vi Rich dung mi i qua tua bin thy lc Bypass Van
(LV101B & C) v i vo Flash Drum (D-01).
Da dung mi t di cng ca ct Stripper (T-02) c bm vo Absorber Ct do Lean
Solvent Bm A hoc S & B (P-03 A hoc S & B). Da dung mi bm A (P-03A) v da
dung mi bm S (P-03s) c bm ng c Driven v da dung mi bm B (P-03B) l
Turbine Driven bm (Turbine thy lc).
Da dung mi bm S (P-03s) l mt my bm d phng c th c thc hin trn
ng khi P- 03A khng duy tr dng chy lu thng cn thit.
ProSimulator
2.3 Stripper Section
Stripper Section consists of the following equipments,
Flash Drum (D-01)
Stripper Column (T-02)
Reflux Drum (D-02)
Lean Solvent Exchanger 1 (E-01)
Stripper Overhead Condenser (E-04)
Steam Reboiler (E-05)
Hot Oil Reboiler (E-06)
Rich Solvent from Absorber flashes into the Flash Drum (D-01) partly stripping off CO
2 present. Flash Drum is maintained at a pressure of 0.72 Kg/cm2 (g).
Rich Solvent from the bottom of the Flash Drum after getting preheated by Lean Solvent
from the Stripper Bottom in Lean Solvent Exchanger (E-01) enters Stripper Column above
Tray 3. Stripper is maintained at a pressure of 0.63 Kg/cm2 (g).
Similar to Absorber column, top two trays are wash section of Stripper Column. Wash
section is fed with Reflux Drum (D-02) Bottom Liquid.
Rich Solvent as it cascades down within the Stripper Column countercurrent to a
flow of rising steam and carbon dioxide, strips off the CO 2 from the solvent. The solvent
gets progressively hotter, releasing CO 2, as it continues flowing down the column. The
liquid accumulates in a chimney tray sump and circulates through the stripper reboilers (E05 & E-06).
The stripper reboilers E-05 & E-06 provide the heat required for generating steam. In
steam Reboiler (E-05), steam is used as the heating medium and in Hot Oil Reboiler (E06), Hot Oil is the heating source. In stripper reboilers, steam is generated and CO
liberated along with it. CO 2 and steam vapors return back to the stripper, providing vapor
stripping action required to regenerate the MEA solution.
2 is
The liquid in the reboiler overflows to the bottom of the stripper. Temperature of the bottom liquid in
Stripper is maintained at 121.0 Deg C at which the concentration of lean amine is maintained. By
controlling the boiling point of the solution, the concentration of the lean solvent is controlled.
Lean solvent from the bottom of the Stripper is pumped to Absorber by Lean Solvent
Pumps.
Vapors along with CO 2 exits the top of Stripper Column and combines with exit
vapors from Flash Drum. These vapors are then condensed in Stripper Overhead
Condenser (E-04), which are then separated from CO
Drum is maintained at 0.5 Kg/cm2 (g). Reflux Drum bottom liquid is circulated back to
Wash Section of Stripper by Reflux Pumps (P-04 A/B).
2.3 Mc Stripper
Stripper mc bao gm cc thit b sau y,
Flash Drum (D-01)
Stripper Ct (T-02)
Tro ngc Drum (D-02)
Nghing Solvent trao i 1 (E-01)
Stripper ngng Overhead (E-04)
Hi Reboiler (E-05)
Hot Du Reboiler (E-06)
ProSimulator
FIC101
Dng chy ca kh Thc n tng hp hp th Ct c kim sot mc 113.7 TPH bi mt dng iu
khin FIC101 lin kt vi van iu khin FV101.
FIC102
dng chy ra nc phn Absorber Ra c kim sot mc 1.3m3 / hr bi lung iu khin FIC102
lin kt vi FV102.
FIC103
Da dung mi Flow Absorber Ct c kim sot mc 529,6 m3 / hr bi lung iu khin FIC103 lin
FV103 A / B. y l mt b iu khin tm Chia
ProSimulator
LIC103
Flash Drum Level is maintained at 48.4% by LIC103, which is linked with the control
valve LV103.
LIC104
Reflux Drum Level is maintained at 51.4% by LIC104 linked with control valve LV104.
LIC102
Absorber Ra phn Cp c kim sot mc 52,6% ca LIC102 c lin kt vi van iu
khin LV102.
LIC103
Flash Drum cp c duy tr mc 48,4% ca LIC103, c lin kt vi cc LV103 van iu khin.
LIC104
Tro ngc Drum cp c duy tr mc 51,4% ca LIC104 lin kt vi van iu khin LV104.
ProSimulator
3.3 Pressure Controllers
PIC101
Knock Out Drum Pressure is maintained at 25.7 Kg/cm2 (g) by the pressure controller
PIC101 linked with control valve PV101.
PIC102
Reflux Drum Pressure is maintained at 0.5 Kg/cm2 (g) by the pressure controller PIC102
linked with control valve PV102.
PIC103
Flash Drum Pressure is maintained at 0.72 Kg/cm2 (g) by the pressure controller PIC103
linked with control valve PV103.
3.3 B iu khin p sut
PIC101
Knock Out Drum p sut c duy tr mc 25,7 kg / cm2 (g) ca PIC101 iu khin p
lc lin kt vi van iu khin PV101.
PIC102
Tro ngc Drum p sut c duy tr mc 0,5 Kg / cm2 (g) ca PIC102 iu khin p
lc lin kt vi van iu khin PV102.
PIC103
Flash Drum p sut c duy tr mc 0,72 kg / cm2 (g) ca PIC103 iu khin p lc
lin kt vi van iu khin PV103.
HIC103
Quench Water circulation flow is manually controlled using HIC103.
ProSimulator
B iu khin nhit 3.4
TIC101
Stripper Nhit di c duy tr 121,0 C ca iu khin nhit TIC101, c lin kt vi TV101.
HIC101
Dng chy ca kh Sn phm t K.O Drum n gii hn ca pin iu khin bng tay s dng
HIC101.
HIC102
cung cp nit cho p lc cho cc Absorber v K.O Drum qu trnh khi ng c iu khin bng tay dng HIC102.
HIC103
dng chy lu thng tt la nc c iu khin bng tay dng HIC103
HIC104
Quench water flow from K.O Drum to Reflux Drum is manually controlled using
HIC104.
HIC105
Bypass flow of Lean Solvent Cooler is manually controlled using HIC105.
HIC106
Lean Solvent Flow through Hydraulic Turbine is manually controlled using HIC106.
HIC107
Lean Solvent Flow through Bypass Valve LV-101C is manually controlled using
HIC107.
HIC109
CO2 to Battery Limit Flow is manually controlled using HIC109.
HIC110
Hot Oil Flow into Reboiler is manually controlled using HIC110.
HIC111
Makeup Solvent Flow is manually controlled using HIC111.
HIC104
Dp tt lu lng nc t K.O Drum n tro ngc Drum c iu khin bng tay dng HIC104.
HIC105
dng chy Bypass ca Lean Solvent Cooler c iu khin bng tay dng HIC105.
HIC106
Nghing dng dung mi qua tua bin thy lc c iu khin bng tay dng HIC106.
HIC107
Nghing dng dung mi qua Bypass Van LV-101C c iu khin bng tay dng HIC107.
HIC109
CO2 Battery Gii hn lu lng c iu khin bng tay dng HIC109.
HIC110
Hot du chy vo Reboiler c iu khin bng tay dng HIC110.
HIC111
Trang im dng dung mi c iu khin bng tay dng HIC111.
ProSimulator
4. INTERLOCKS
ProSimulator
5. PROCESS CONDITION SUMMARY
TAG
TAG DESCRIPTION
ENGINEERING
NAME
TYPE DESIGN
VALUE UNIT
CTL 51.1
CTL 52.6
CTL 48.4
CTL 51.4
CTL 1.3
CTL 25.7
Kg/cm2 (g)
CTL 0.5
Kg/cm2 (g)
CTL 0.72
Kg/cm2 (g)
MLD 17.9
MLD 0.0
MLD 70.3
MLD 0.0
MLD 11.3
MLD 100.0 %
HIC107 Lean Solvent Flow through Bypass Valve LV-101C MLD 0.0
m3/hr
MLD 100.0 %
MLD 50.0
MLD 0.0
IND 53.7
IND 49.3
ProSimulator
FI101 Boiler Feed Water Flow
IND 0.00
m3/hr
IND 1.57
m3/hr
IND 10.3
m3/hr
IND 0.00
m3/hr
IND 0.0
TPH
FI106 Product Gas Flow from K.O Drum to Battery Limit IND 52.9
TPH
IND 0.00
TPH
IND 56.6
m3/hr
FI109 Lean Solvent flow through Lean Solvent Pump A IND 395.5 m3/hr FI110
Lean Solvent flow through Lean Solvent Pump B IND 162.0 m3/hr
FI111 Rich Solvent Flow through Hydraulic Turbine
FI112 Lean Solvent Flow through Lean Solvent Pump S IND 0.0
m3/hr
IND 8.28
TPH
IND 0.0
m3/hr
IND 18.6
TPH
IND 45.8
TPH
IND 14.6
m3/hr
IND 30.0
Kg/cm2 (g)
IND 26.0
Kg/cm2 (g)
IND 0.63
Kg/cm2 (g)
IND 0.63
Kg/cm2 (g)
IND 0.28
Kg/cm2
IND 0.21
Kg/cm2
ProSimulator
TI101 Feed Gas Temperature
IND 48.4
Deg C
IND 86.5
Deg C
TI103 Lean Solvent Temperature (at the inlet to Absorber) IND 37.4
Deg C
TI104 Rich Solvent Temp (at the inlet of Flash Drum) IND 93.7
Deg C
IND 0.06
IND 54.14 %
IND 36.4
IND 0.0
IND 100.0 %
IND 4.9
IND 0.0
6. MALFUNCTIONS
ProSimulator
E-01 Flow Fouling Increased Tube side flow through E-01 Decreases. FIC103
Decreases.Stripper Level increases (LI101).
K.O Drum Pressure (PIC102) Decreases.
SLNO FAILURES
CHANGE EFFECTS
Steam Condensate flow (FIC102) drops to zero.
High CO2 in Feed gas On Outlet Increases. Absorber Bottom Temperature (TI102)
Increases.
Amine Treating Unit
17
ProSimulator
Lean Solvent flow into Absorber (FIC103) Drops.
4
P-04A/B Fail On
Valve Blow On
ProSimulator
7. STARTUP PROCEDURE
SL NO DESCRIPTION
Pressurization of Absorber with Nitrogen
Take K.O Drum Pressure Controller (PIC101) (GR02) in Auto mode and set 25.7
Kg/cm2 (g) as its set point.
Open Absorber Top to K.O Drum On-Off valve HV114 (GR06) .
Pressurize K.O Drum and Absorber by opening HIC102 (GR06) till 7.0 Kg/cm2 (g).
Close Nitrogen Supply HIC102 after pressurizing till 7.0 Kg/cm2 (g)
Establishment of Solvent Circulation
Open Solvent Makeup valve HV111 using Manual Loading Station HIC111 and charge
the solvent into Stripper Bottom.
Allow level to buildup in Stripper till 60% (LI101) (GR04) .
Open P-03A suction valve HV118 (GR08) .
Start P-03A (GR08)by clicking on the pump.
Open P-03A Discharge valve HV119(GR08).
Open FV103A manually using FIC103 (GR02)and charge Solvent into Absorber.
Allow level to buildup in Absorber till 60% (LIC101)(GR02).
Reset XV101 ESD using BYP101 & RST105(GR05).
Ensuring HIC106 at 0%, Open LV101B manually using LIC101(GR02) setting its
output above 50% and charge Flash Drum with Solvent.
Allow the level of Flash Drum to buildup till 50% (LIC103)(GR04).
Open LV103 manually using LIC103(GR04) and then charge Solvent into stripper trays.
(After filling of trays, Reboiler gets filledup. After filling of Reboilers solvent
overflows into Stripper Bottom.)
Establish circulation of 250m3/hr with Absorber at 7.0 Kg/cm2(g).
Open Cooling water to Stripper Condenser (E-04) using On-Off valve HV127(GR07).
ProSimulator
Raise the temperature of circulating Solvent till 120 Deg C slowly by manually
charging steam into Reboiler (E-05) using TIC101 (GR04)or manually charging Hot Oil
into Hot Oil Reboiler (E-06) using HIC110 (GR07).
Take Lean Solvent flow controller (FIC103) (GR02) in Auto mode with its set point as
250m3/hr.
Open Amine Guard System Block valve HV160 (GR06) to establish continuous flow
through Amine Guard Inhibitor System.
Take Absorber Level Controller (LIC101)(GR02) in Auto with its set point of 50%.
Take Flash Drum Level Controller (LIC103) (GR04) in Auto with its set point of 50%.
Take Flash Drum Pressure Controller PIC103 (GR04) into Auto and set 0.72 Kg/cm2
(g) as its set point.
Take Reflux Drum Pressure Controller PIC102 (GR04) into Auto and set 0.5 Kg/cm2
(g) as its set point.
Allowing temperature of Lean Solvent to raise, simultaneously start filling Condensate
in K.O Drum (D-03) and Reflux Drum (D-02) (GR04) adopting the following
procedure.
Commissioning of K.O Drum and Reflux Drum
Start Steam Condensate Pump (P-01)(GR02) .
Open Block valve HV116 (GR06) and then open HV103 to 5% using HIC103 (GR04)
and charge condensate into K.O Drum (D-03).
Allow K.O Drum Level (LI102) (GR02) to buildup till 30%.
Once K.O Drum Level reaches 30%, keeping HIC103 (GR04) at 70% open, start Quench water
circulation pump (P-02) (GR02) and establish Quench water circulation
of around 10m3/hr.
Allow K.O Drum Level (LI102) (GR02) to buildup till 50%.
Open HV104 using HIC104 (GR06) and allow condensate to buildup level (LIC104)
(GR04) in Reflux Drum (D-02) till 25%.
ProSimulator
Once Reflux Drum Level (LIC104) (GR04) reaches 30%, open Reflux pump Suction
valve (HV123/HV125)(GR07)and start Reflux Pump (P-04A/B) and then open
32
(HV124/HV126) (GR07).
Open LV104 using LIC104 manually and establish Reflux flow (FI120)(GR04)
33
34
Take Reflux Drum Level Controller (LIC104) (GR04)in Auto with its setpoint as 50%.
Pressurization of Absorber with Feed Gas
Open Feed Gas Block Valve HV113 (GR06) and slowly pressurize Absorber with Feed
gas using FIC101(GR02) in Manual mode till 26.0Kg/cm2 (g) (PI102). (Pressurization
must be performed very slowly such that levels of Absorber, Stripper and Flash Drum
35
are maintained.)
Increase Lean Solvent flow to 60-70% of Design Flow (FIC103) (GR02)around
36
350m3/hr.
Charge cooling water into Lean Solvent Cooler (E-03) using HV117(GR06) and
maintain the temperature of Lean Solvent into Absorber temperature TI103 at 37.8 Deg
37
38
01).
Commissioning of Wash Section
39
Open FV102 using FIC102 (GR02)and charge Wash Water into Absorber Wash Section.
40
41
Take FIC102(GR02) into Auto mode with its set point as 1.3 m3/hr.
Open LV102 using LIC102 (GR02)and establish wash water circulation to Reflux Drum
42
43
Take LIC102 into Auto mode with its set point as 50%.
Establishment of Feed Gas flow
44
Slowly Establish Feed gas flow through Absorber till less than 50% of design flow.
45
ProSimulator
When the Product gas meets the specification of 0.06% (mass) of CO2 (AI101)(GR02),
slowly open Product Gas to Downstream unit valve HV101 using HIC101
46
(GR02)maintaining the pressure of the Absorber and K.O Drum at Operating Value.
Maintain the stripper Bottom temperature TIC101 (GR04)at Design value of 121 Deg C
47
manually.
(If required take Hot oil Reboiler (E-06) into line by opening Hot Oil into Reboiler using
HIC110.)
Stabilization of Plant
Slowly increase the Feed gas flow through Absorber (FIC101)(GR02) keeping the Feed
gas flow controller in Auto mode by slowly incrementing the set point of it till Design
48
49
50
Design value.
51
Take Stripper Bottom Temperature Controller (TIC101) (GR04)in Auto with its set
point as 121.0 Deg C
Commissioning of Hydraulic Turbine (X-02)
Open Lean Solvent Pump (P-03B)(GR03) Suction valve HV120 (GR08) and Discharge
52
valve HV121(GR08).
53
Slowly charge Rich Solvent into Hydraulic Turbine by increasing the output of
HIC106(GR03).
(Initially till 50% of the Design rate of flow through Turbine, the Hydraulic Turbine will
not produce any net power. Above 50% of the Design flow rate, Turbine will produce net
power and speed of P-03B increases consequently Lean Solvent flow rate through
54
P-03B increases.
Slowly raise the flow across Turbine using HIC106 (GR03)till 100% such that Lean
55
Solvent Flow is not disturbed much and levels of Absorber, Stripper and Flash Drum are
Amine Treating Unit
22
ProSimulator
maintained.
8. SHUTDOWN PROCEDURE
S.NO
DESCRIPTION
Stop Feed gas flow rate into Absorber using FIC101 (GR02)and block valve
HV113(GR06) in the Feed gas line.
Line out Hydraulic Turbine by reducing HIC106 (GR03)output to zero slowly. Slowly
close Product gas to Downstream unit valve using HIC101(GR02) and maintain the Absorber
pressure at 7.0 Kg/cm2 (g) using PIC101(GR02). This will take considerable
3
(E-06) using HIC110(GR07) and reducing steam flow rate into Steam Reboiler
(E-05) manually using TIC101 (GR04) and maintain the temperature at 80 to 90 Deg C.
Stop Condensate flow to Absorber Wash section using FIC102 (GR02)and put OFF
5
Absorber (T-01) pressure at around 7.0Kg/cm2 (g) for maintaining the circulation. Reduce
Stop Quench Water Circulation Pump (P-02) and drain K.O Drum (D-03) to Reflux Drum
(D-02) using HIC104(GR06).
10
ProSimulator
11
12
Stop Reflux Pump (P-04A/B) and start draining condensate using HIC130(GR07).
13
Depressurize Flash Drum (D-01) and drain it to Stripper (T-02) using LIC103(GR04).
Depressurize Absorber (T-01) to 0.2 Kg/cm2(g) using PIC101 for further shutdown
14
process to continue.
15
ProSimulator
9.
ProSimulator
ProSimulator