PP Pad Demister

Knit Mesh Demister

Operating temperature (min)

32 F

-320 F

Operating temperature (min)

170 F

1500 F

150 x 10 ^-6 / C
520 720 MPa
210 MPa
8.03 g/cm3
$12- 23/ sq.m

17.3 x 10 ^-6 / C
33 MPa
48.2 MPa
0.905 g/cm3
$9-20/ sq.m

low
93-96.9
Hydrophilic,oleophilic

high
97.5-99.4
Hydrophilic,oleophilic

Heat Distortion temperature at 20 C


Tensile strength
Compressive strength
Density
Cost
(Width: 1-2 m, Length :within 1500mm, Thickness: 3-12mm)

Chemical resistance
Void fraction
Surface characteristic
Efficiency
For droplet size

Droplet size is directly proportional to efficiency (keeping the same velocity


and liquid and gas composition).
For strand diameter or corrugation spacing
The smaller the diameter of a mesh strand, the more abruptly oncoming gas
turns aside, and the more difficult it is for mist droplets to follow the gas.
Thus, finer strands can
For gas velocity
Capture efficiency of a mist eliminator increases sharply with velocity until an
upper limit is reached due to re-entrainment or flooding.
Liquid density relative to gas density
In cases where the gas is nearly as dense as the liquid for instance, at high
pressuresthe gas sweeps droplets around the obstacle more strongly,
preventing capture.
Gas viscosity
The more viscous the gas, the more drag it exerts on suspended droplets as
the gas flows around mesh strands, leading to reduced capture efficiency.

Pad density and thickness


Thicker, denser pads bring trade-offs in terms of higher pressure drop and
susceptibility to re-entrainment and flooding.
Effect of void fraction
The separation efficiency is enhanced clearly as the void fraction is
decreased.
Chemical Resistance
Polyproylene
Severe Effect
No effect
Severe Effect
No Effect
No Effect
No Effect

Propane
Propylene
Butane
Butylene
Water
H2S

Stainless steel 304


No Effect
Minor Efect
No Effect
Minor Effect
No Effect
Severe Effect

Fouling applications
Mild fouling:
Install a water spray system below the mist eliminator for occasional
inline cleaning
Consistent fouling:
Install Vane mist eliminator upstream of the mesh mist eliminator

Features
PP Pad Demister

Absolute separation of bigger size liquid particles


Suitable for the operation under extreme temperature and
pressure conditions
Minimal pressure loss
Excellent separation efficiency
Maximum inflow area
Can sustain in the high temperature and corrosive conditions
Suitable for aggressive media

Knit Mesh Demister

Simple structure
Small size
Light weight
Excellent porosity
Minimum pressure drop contact
Large surface area
Excellent separation efficiency
Easy maintenance
Reduce the value of material losses
Ensure protection of the environment

Reduction in air pollution


Prevent electrical interference shielding of electronic devices

Considerations

To obtain minimum pressure drop, maximum throughput, and maximum


efficiency, the support grids must have a high percentage of free passage. To
take full advantage of the 98% or so free volume in the wire-mesh, the free
passage through the support grids should be greater than 90%. If the free
passage through the support grids is much below 90%, the accumulated
liquid is prevented from draining back through the support grids, causing
premature flooding.