Académique Documents
Professionnel Documents
Culture Documents
Submitted To
Submitted by
IMRAN AHMED
B.Tech 6th semester
Bipin Tripathi Kumaon Institute of Technology,
Dwarahat
ACKNOWLEDGEMENT
It is said that behind any accomplishment of any effort there are some
dedicated individuals who put in their best to get the job done.
I also want to express my full thanks to Mr. D. K. Singh (A.M.), Mr.
Place
Date
Imran Ahmed
Date:
Mr. Nitesh Jain
Place:
Manager- Quality
PepsiCo India
holdings Pvt. Ltd.
BA
ZPUR
Index
NO.
Topics
Page no.
1-2
3-4
5-16
Types of water
3.1 Raw water
3.2 Treated water
3.3 Soft water
3.4 Soft recovery water
Syrup preparation
RM/PM testings
19-25
Glass line
25-27
Conclusion
28
References
29
16-19
INTRODUCTION
Soft drinks constitute one of the largest beverage industries in the world today.
Tremendous advances have taken place in the process technology in the soft drink industries in the
past one or two decades.
The beverages are divided into two groups i.e. carbonated soft drinks like Pepsi,
Mountain Dew, M. orange, 7 Up etc. & non-carbonated soft drink like Slice.
The major ingredients of soft drinks are
a) Water
b) Sugar or sugar substitute
c) Carbon dioxide
d) Flavor emulsion and emulsifiers
e) Coloring agents
f) Acids and preservatives
Origin Of Pepsi
In North Carolina, Mr. Caleb Bradham who was a pharmacist by profession invented a new
beverage in year 1898, which was called Brads Drinks (evocation of a digestion aiding enzyme
pepsin). This brads drink was later called PEPSI COLA. Pepsi Cola trademark was registered in
1903.Bradham believed marketing would be the key to Pepsi cola. He spent $ 1900 on advertising
when he sold only 40,000 liters of syrup.
In 1905, Bradham build Pepsis first bottling plant. Three (3) more plants followed soon and in
1907, he was selling 50,000 liters per year. In 1909, he hired a new advertising agency.
Troubles started at the end of the world war 1 st when Bradham overstocked sugar at high price
which subsequently dipped to rock bottom in 1920. by 1922, the company was insolvent and by
1923, it went bankrupt. Bradham returned to his pharmacy.
Roy Megargell, a wall street broker stepped in and reorganized the company. However the company
was running a loss each year and with the stock market crash in 1929. Megargell was not able to
upkeep the company any longer in 1930.
by the U.S. headquarters MNC to enter India. PepsiCo would have an equity holding of 39%,
Punjab Agro Industries Corporation (PAIC) 20% and Voltas 24%. The rest had to be financed
privately from loans. A project approval board was finally set in February 1988. Pepsis share which
have been originally just under 40% and PAIC 35% then PAICS share was hiked to 40% these
were mainly the issue in which COKE had left India in 1977. Thus Pepsi not only accepted the
1977 conditions but also went much further. Now the Pepsi project had captured the farmers
imaginations. Finally there was victory for Pepsi who after more than 5 years of acrimonious battle
was launched in June 1990 selectively in Rajasthan, Punjab, Uttar Prades and South as LAHERPEPSI.
6. Manufacturing Area:
Line 1: PET 600 ml
Line 2: PET 600 ml, 1ltr, 2ltr,
2.25ltr
Line 3: PET 1ltr Aquafina
Line
4:
GRB
(Glass
Returnable Bottles) 200ml,
300 ml
1. RM/PM TESTINGS
RM PM is raw material & packaging material which is subsistently is a
inventory quality control method for assuring good quality measure in inventory
& packaging material
4.1. Tests Performed On Sugar
Reading * 1000
(A cm cell length)* (B g/ml solid)
Where,
A, sample cell path length in cm
B, sample solids concentration in g/ml.
Test-2 Turbidity Test
Turbidity =
Equipment:
Ash%
= 21.22/1666.7
= 0.0127%
3.
4.
5.
6.
7.
8.
9.
Drying oven
Drying dishes ,2- aluminum to support filter dishes in oven
Hot plate
Analytical balance capable of weighing to 0.0001 g.
Balance capable of weighing to 1 g.
Stirrer - electric rod immersion type
Beaker 1 liter and 0.5 liter capacity.
1-Moisture (max)-10%
3. Commercial Salt:-specification
1-Purity not less than 97.5% on a dry basis.
%(Purity)=TR*0.1*.05844*100/wt. of sample.
4. Caustic Soda Flakes:- specification
1-Purity not less than 96%.
%(purity)=TR*0.8*100/wt. of sample.
5. HCL:-specification
1-purity not less than 31.5%
6. Hydrated Lime:-specification
1-purity-Available CaO=66%(>90%as Ca(OH)2)
2-Inert material=none
%(purity CaO)=TR*1.87/wt. of sample
%(Ca(OH)2)=% of CaO*75/56
7. Bleaching powder:-specification
1-Available Cl2=>70% by weight.
%Cl2=TR*14.184/wt. of sample
8. Hyflow Super cell:-specification
1-Color-light pink to white
2-PH value-10(max)
3-moisture-0.5%(max)
9. Testing of Water(WTP)
Hardness
Softness
Alkalinity
Chlorine
10. Testing of flavour & Salt
Testing of flavour & salt are performed in Channo plant Punjab.
Flavour made up of two parts Concentrate
Acid part
Packaging materials
1. Cartons Test-To measure Length, Width, Height, Printing, GSM.
2. Wrap around-To measure Length, Width, Center to Center, Printing, GSM.
3. Closures- To measure Weight, Height, SST, and Printing address, CDV, FPO,
CHL no.)
4. Crowns-To measure Weight, Go/No Go, Printing(address, CDV, CMD,
Nutritional information, Ingredients, CAT-1 & CAT-3), Corrosion Test, Liner
Adhesion,
5. Labels-To measure Coil Width, Repeat Length, Coil ID, Coil OD, Core
Thickness
Visually Check (plant address, nutritional information, ingredients, CAT-1 &
CAT-3), GSM
6. Sleeves- To measure Coil Width, Repeat Length, Coil ID, Coil OD, Core
Thickness
Visually Check (plant address, nutritional information, ingredients, CAT-1 &
CAT-3), GSM.
7. Empty Glass Bottles- To measure Weight, Height, Base Diameter, Shoulder
Diameter, Brimful Capacity, and Volume at fill point, Mould Number.
8. Preform tests TO measure Height, Weight, Neck finish, Internal neck
diameter, External neck diameter, Preform diameter, Gate height, Preform defects
in Polariscope
PURPOSE:- The purpose of the 2P-M or alkalinity test is to verify that the
water treatment plant is operating correctly and that the final treated water used
for the processing conforms to standards. High alkalinity in process water will
have an undesirable effect on the taste of the finished beverage.
PRINCILAL OF OPERATION:-
excess of hydroxide alkalinity, is correct. At the same time, the method measure
M the total alkalinity. The P alkalinity represents all of the hydroxide alkalinity,
and one half of the carbonate alkalinity. The alkalinity relationship is based on the
fact that the bicarbonate and hydroxide from cannot co-exit.
There are two approved method for measuring the alkalinity of the water. One
uses two colorimetric indicators, which change the color of the solution under test;
this is suitable for operation that does not have access to pH meter. The other
method is preferred since it removes the subjectivity of interpreting a color change
and uses a pH meter to determine the test result.
REASENT :
2.HARDNESS (CALCIUM & TOTAL):PURPOSE:- Water hardness is treated for at least two reasons :
PRINCIPAL OF OPERATION:-
2CaCO3 + 2H2O
Mg(HCO3)2 +2Ca(OH)2
CaCO3 + 2NaCL
Calcium hardness, when present in moderate amounts (Less than 70ppm.) does
not adversely affect traditional soft drinks. (For example. Pepsi, 7UP,
Orange.)There fore no special effort
Water used for sanitation purposes should be from a sanitary supply. If the water is
form a municipal supply with good quality characteristics and meets sanitary
criteria, it can be used for without further treatment for other
Sanitation programs.
If the plant water supply tests positive for coliform or contain any other
dangerous organism, this supply cannot be used in the sanitation process.
If the water is form an acceptable water supply and taste negative for coliform,
then simple chlorination is sufficient, maintaining approximately 0.2ppm free
available chlorine at the outlet.
In Pepsi Co. India Holdings Pvt. Ltd., Bazpur, the three types of
water used :
Raw water
Soft water
Treated water
We use raw water for storage purpose, drinking, canteen use etc.
Soft water used for cooling tower, bottle washer and boiler. Treated water used for
syrup and beverage making.
Raw water is pumped up by bore well & put to various treatment to obtain
Treated Raw water, having hardness due to Ca++ & Mg+ ions is softened with
the help of sodium zeolite. Which act as a softner. It absorb all hardness present in
the water it is the replaced periodically after use.
Soft water is mainly used for washing purpose. it is also used in boiler and
refrigeration empty bottles & equipment are washed using soft water.
Brix: It is the amount sucrose present in solution. 1 brix means 1 gram of sugar
in 100 grams of water. It is measured by refractometer.
Objective: To check the amount of sucrose present in the product.
Equipment1. 250 ml glass cylinder
2. Refractometer
3. 300 ml stainless steel breaker
4. Dropper
5. Tissue paper
Procedure:
1. Sample preparation
1.1 For sample syrup, finished syrup and control drink take sample directly.
1.2 For carbonated beverage degas the sample.
2. Clean refractometer prism with distilled water and wipe it dry with tissue
paper.
3. Using a cleaned and dried eye dropper place a drop of distilled water on the
prism surface so as to cover it fully, close prism cover and press READ
key.
4. If reading is showing 0.00+-0.01 then proceed with the measurement.
1. Wipe the water from the prism dry and place a drop of the testing sample,
so as to cover the prism avoid gas bubbles by degassing the sample prior
to testing if required.
6. Close the prism cover and press READ key.
7. Once the display stabilizes on the screen it is desirable to take another
confirmatory reading by pressing the READ key again.
8. Record result.
Factors that have direct effect on brix are:
Note: Beverage brix at times found out of target at start up, during batch change
over and at the end.
Reasons:
1. Sop not established/ standardized or not being followed rigidly.
2. Lack of knowledge of chemist/ operator to operate mix processor.
3. Syrup line not flushed properly before taking syrup leading to dilution of syrup
in the initial stage.
4. Co2 pushing is not used to flush water.
5. Mix processor and filler are not flushed with sufficient beverage (10 psi co2
pressure to be used for flushing).
6. Air entrapment in the syrup during batch change and end production leading to
low brix.
7. Water being used in some plants to push syrup instead of co2.
8. Mishandling of refractometer.
Keep the bottle in boiling water for 40 minutes.(time starts only when the
water starts boiling).
Cool it to 20 c.
Add correction factor based on the flavor as per the beverage document.
Aim: A control drink is an individual drink made by hand. A control drink may be
made with treated water to find out what the line beverage target for titratable
acidity or brix should be and if the taste of the finished beverage is acceptable.
Reagent/ Chemical: syrup and treated water
Process Flow Diagram:
Acquire well mixed syrup sample
Mix syrup and treated water in 1:5
ration in a CD flask; for mirinda
make the ratio 1:4
Control drink to be made two hours prior to production and then every 4
hours.
Syrup brix must also be checked while making control drink. It gives an idea
about the accuracy of control drink.
Dont forget to add 0.4 ml of 2.5 N HCl in flavors except Pepsi for every 35
ml of beverage before inverting.
Leaking buckets.
Brix variation.
Too much foam on the conveyor: possibility of foam entering in the bottle
which neutralizes the acid.
Test-2 pH Test
Purpose: This method will provide an overview of pH measurement of water.
Equipment: pH meter, thermometer, 250 ml beaker, tissue paper.
Reagent/Chemical: Distilled water (for rinsing electrode)
Procedure:
1. Use a conditioned pH electrode and a calibrated pH meter.
2. Turn on pH meter.
3. Rinse the electrode thoroughly with distilled water and dab dry with disposable
tissues.
4. Pour the water to be analyzed into a clean beaker.
5. Carefully place in clean, dry stir bar into beaker containing water.
6. Allow pH to stabilize and record pH to the nearest 0.1 pH unit.
7. Rinse electrode with distilled water.
Line-4 Glass line
This line produces 200ml and 300ml of reusable glass bottles. This is a very
important segment of plant. It is also very important from quality point of view as
it is very prone to microbial growth.
Main component of glass line is: Bottle washer, filler, Coding machine and case
packer.
6.3.1
Advantage
Caustic has germicidal action.
Caustic is a good cleaning agent.
Disadvantages
Caustic alone is not effective.
It cannot penetrate
It enhances scale formation due to formation of carbonates.
It attacks the bottle surface.
Additive (su)
It enhances the cleaning affect.
It softness mold pads & dirt in the bottles.
It increases rinsibility of caustic solution.
It prevents scale formation.
Helps to settle particulate matters.
Hence caustic soda with su-260 (as recommended by pfl) to be used.
Hydro spray:
To remove caustic residue.
To remove dissolved/ suspended dirt from bottles
To reduce temperature gradually to avoid thermal shock
e) Pre final rinse :
To remove left over caustic residue.
To further reduce temperature of the bottles.
Removal of caustic trance and cooling of bottle ( 1 to 2 ppm cl2).
f) Final rinse :
Bottles washed with soft water with 1.0 ppm free chlorine.
Water should be free from any particles.
Removes caustic residue fully.
g) Out feed : It receive bottle from carrier and guides to the conveyor.
Flow diagram of bottle washer system
Bottle feed
Pre Rinse
First Soak
Caustic 1.5 %
At 55 deg C
Caustic 2.5
Main Soak
At 70 deg C
Soft water
Hydro Spray
Bottle Out