ISO 9906:1999(E)
Fluctuations: short-period changes in the measured value of a physical quantity about its mean value during
the time that a single reading is being made.
b)
Variations: those changes in value which take place between one reading and the next.
13
ISO 9906:1999(E)
ISO
Annex A
(normative)
Tolerance factors for pumps produced in series with selection made from
typical performance curves and for pumps with a driver power input less
than 10 kW (relevant to series pumps grade 2)
NOTE
This annex applies only to the allowable working range of the pump.
A.1 Pumps produced in series with selection made from typical performance curves
The performance curves in catalogues represent the mean (not the minimal) performances of a series of pumps of
the same type. This appIies also to efficiency and power input. Therefore increased tolerances and even tolerances
on power are necessary.
When the manufacturer/supplier makes reference in his catalogue to this annex, the following maximum factors
shall be used:
tQ = 9 %
tH = 7 %
tP = + 9 %
tPgr = + 9 %
for efficiency
t = 7 %
flow rate
tQ = 10 %
tH = 8 %
The tolerance factor on efficiency, t, if not otherwise agreed, may be calculated as follows:
Pgr
th = 10 1
+ 7 %
10
where Pgr is the maximum driver power input in kilowatts over the range of operation. A tolerance factor tPgr is
allowed using the following formula:
t Pgr =
NOTE
parties.
42
(7 %)2 + th2
For pumps with very small power input (less than 1 kW), another special agreement may be decided between the