IP Rating Chart
Learn what IP means and what
rating is best for your application.

Resources
IP Rating Chart
Glossary of common electrical terms
Cable Jacket Types
Termination Options

Products & Services


Custom Power Cables
Wire Harnesses
Over Molding
Developmental Services (R&D)
Cable & Wire Extrusion
MoistureBlock Technology

Company Info
About Us

http://www.dsmt.com/resources/ip-rating-chart/

8/30/2016

IP Rating Chart | DSMT.com

Page 2 of 19

Our Capabilities
Contact Us
FAQs
Patents
Compliances

Click Here to view/download a PDF Version of thiscompliance letter.

Sample IP Rating

IP

Ingress

First Digit: Solids

Second Digit:

Protection

Protection

Liquids Protection

Ingress Protection (IP) and what it means


The IP Code (or International Protection Rating, sometimes also interpreted
as Ingress Protection Rating*) consists of the letters IP followed by two digits
and an optional letter. As defined in international standard IEC 60529, it
classifies the degrees of protection provided against the intrusion of solid
objects (including body parts like hands and fingers), dust, accidental contact,
and water in electrical enclosures. The standard aims to provide users more
detailed information than vague marketing terms such as waterproof.
The digits (characteristic numerals) indicate conformity with the conditions
summarized in the tables below. For example, an electrical socket rated IP22 is
protected against insertion of fingers and will not be damaged or become
unsafe during a specified test in which it is exposed to vertically or nearly
vertically dripping water. IP22 or 2X are typical minimum requirements for the
design of electrical accessories for indoor use.

http://www.dsmt.com/resources/ip-rating-chart/

8/30/2016

IP Rating Chart | DSMT.com

Page 3 of 19

*Explanation of the letters IP is given in IEC 60529 (Ed. 2.1), clause 4.1

First Digit: Solids


The first digit indicates the level of protection that the enclosure provides
against access to hazardous parts (e.g., electrical conductors, moving parts) and
the ingress of solid foreign objects.
Object size
Level

protected

Effective against

against
0

Not

No protection against contact and

protected

ingress of objects

>50mm

Any large surface of the body, such as


the back of the hand, but no
protection against deliberate contact
with a body part.

>12.5mm

Fingers or similar objects.

>2.5mm

Tools, thick wires, etc.

>1mm

Most wires, screws, etc.

Dust

Ingress of dust is not entirely

Protected

prevented, but it must not enter in


sufficient quantity to interfere with the
satisfactory operation of the
equipment; complete protection
against contact.

Dust Tight

No ingress of dust; complete


protection against contact.

Second Digit: Liquids


Protection of the equipment inside the enclosure against harmful ingress of
water.

http://www.dsmt.com/resources/ip-rating-chart/

8/30/2016

IP Rating Chart | DSMT.com

Page 4 of 19

Object size
Level

protected

Effective against

against
0

Not

protected
1

Dripping

Dripping water (vertically falling drops)

water

shall have no harmfull effect.

Dripping

Vertically dripping water shall have no

water when

harmful effect when the enclosure is

tilted up to

tilted at an angle up to 15 from its

15

normal position.

Spraying

Water falling as a spray at any angle up

water

to 60 from the vertical shall have no


harmful effect.

Splashing

Water splashing against the enclosure

water

from any direction shall have no


harmful effect.

Water jets

Water projected by a nozzle (6.3mm)


against enclosure from any direction
shall have no harmful effects.

Powerful

Water projected in powerful jets

water jets

(12.5mm nozzle) against the enclosure


from any direction shall have no
harmful effects.

Immersion

Ingress of water in harmful quantity

up to 1m

shall not be possible when the


enclosure is immersed in water under
defined conditions of pressure and
time (up to 1 m of submersion).

Immersion

The equipment is suitable for

beyond 1m

continuous immersion in water under


conditions which shall be specified by
the manufacturer. Normally, this will
mean that the equipment is
hermetically sealed. However, with

http://www.dsmt.com/resources/ip-rating-chart/

8/30/2016

IP Rating Chart | DSMT.com

Page 5 of 19

Object size
Level

protected

Effective against

against
certain types of equipment, it can
mean that water can enter but only in
such a manner that it produces no
harmful effects.

IP Rating Reference Chart


Below is an easy to follow reference chart to help you decide which IP rating you
need or have.
IP
Number
IP00

IP01

IP02

First Digit - SOLIDS

Second Digit - LIQUIDS

Not protected from

Not protected from

solids.

liquids.

Not protected from

Protected from

solids.

condensation.

Not protected from

Protected from water

solids.

spray less than 15


degrees from vertical.

IP03

Not protected from

Protected from water

solids.

spray less than 60


degrees from vertical.

IP04

IP05

Not protected from

Protected from water

solids.

spray from any direction.

Not protected from

Protected from low

solids.

pressure water jets from


any direction.

IP06

Not protected from

Protected from high

solids.

pressure water jets from


any direction.

http://www.dsmt.com/resources/ip-rating-chart/

8/30/2016

IP Rating Chart | DSMT.com

IP
Number
IP07

Page 6 of 19

First Digit - SOLIDS

Second Digit - LIQUIDS

Not protected from

Protected from

solids.

immersion between 15
centimeters and 1 meter
in depth.

IP08

Not protected from

Protected from long term

solids.

immersion up to a
specified pressure.

IP10

Protected from touch

Not protected from

by hands greater than

liquids.

50 millimeters.
IP11

Protected from touch

Protected from

by hands greater than

condensation.

50 millimeters.
IP12

IP13

IP14

Protected from touch

Protected from water

by hands greater than

spray less than 15

50 millimeters.

degrees from vertical.

Protected from touch

Protected from water

by hands greater than

spray less than 60

50 millimeters.

degrees from vertical.

Protected from touch

Protected from water

by hands greater than

spray from any direction.

50 millimeters.
IP15

IP16

IP17

Protected from touch

Protected from low

by hands greater than

pressure water jets from

50 millimeters.

any direction.

Protected from touch

Protected from high

by hands greater than

pressure water jets from

50 millimeters.

any direction.

Protected from touch

Protected from

by hands greater than

immersion between 15

50 millimeters.

centimeters and 1 meter


in depth.

http://www.dsmt.com/resources/ip-rating-chart/

8/30/2016

IP Rating Chart | DSMT.com

IP
Number
IP18

IP20

Page 7 of 19

First Digit - SOLIDS

Second Digit - LIQUIDS

Protected from touch

Protected from long term

by hands greater than

immersion up to a

50 millimeters.

specified pressure.

Protected from touch

Not protected from

by fingers and objects

liquids.

greater than 12
millimeters.
IP21

Protected from touch

Protected from

by fingers and objects

condensation.

greater than 12
millimeters.
IP22

Protected from touch

Protected from water

by fingers and objects

spray less than 15

greater than 12

degrees from vertical.

millimeters.
IP23

Protected from touch

Protected from water

by fingers and objects

spray less than 60

greater than 12

degrees from vertical.

millimeters.
IP24

Protected from touch

Protected from water

by fingers and objects

spray from any direction.

greater than 12
millimeters.
IP25

Protected from touch

Protected from low

by fingers and objects

pressure water jets from

greater than 12

any direction.

millimeters.
IP26

Protected from touch

Protected from high

by fingers and objects

pressure water jets from

greater than 12

any direction.

millimeters.
IP27

Protected from touch

Protected from

by fingers and objects

immersion between 15

http://www.dsmt.com/resources/ip-rating-chart/

8/30/2016

IP Rating Chart | DSMT.com

IP
Number

IP28

Page 8 of 19

First Digit - SOLIDS

Second Digit - LIQUIDS

greater than 12

centimeters and 1 meter

millimeters.

in depth.

Protected from touch

Protected from long term

by fingers and objects

immersion up to a

greater than 12

specified pressure.

millimeters.
IP30

Protected from tools

Not protected from

and wires greater than

liquids.

2.5 millimeters.
IP31

Protected from tools

Protected from

and wires greater than

condensation.

2.5 millimeters.
IP32

IP33

IP34

Protected from tools

Protected from water

and wires greater than

spray less than 15

2.5 millimeters.

degrees from vertical.

Protected from tools

Protected from water

and wires greater than

spray less than 60

2.5 millimeters.

degrees from vertical.

Protected from tools

Protected from water

and wires greater than

spray from any direction.

2.5 millimeters.
IP35

IP36

IP37

Protected from tools

Protected from low

and wires greater than

pressure water jets from

2.5 millimeters.

any direction.

Protected from tools

Protected from high

and wires greater than

pressure water jets from

2.5 millimeters.

any direction.

Protected from tools

Protected from

and wires greater than

immersion between 15

2.5 millimeters.

centimeters and 1 meter


in depth.

IP38

http://www.dsmt.com/resources/ip-rating-chart/

8/30/2016

IP Rating Chart | DSMT.com

IP
Number

IP40

Page 9 of 19

First Digit - SOLIDS

Second Digit - LIQUIDS

Protected from tools

Protected from long term

and wires greater than

immersion up to a

2.5 millimeters.

specified pressure.

Protected from tools

Not protected from

and small wires

liquids.

greater than 1
millimeter.
IP41

Protected from tools

Protected from

and small wires

condensation.

greater than 1
millimeter.
IP42

Protected from tools

Protected from water

and small wires

spray less than 15

greater than 1

degrees from vertical.

millimeter.
IP43

Protected from tools

Protected from water

and small wires

spray less than 60

greater than 1

degrees from vertical.

millimeter.
IP44

Protected from tools

Protected from water

and small wires

spray from any direction.

greater than 1
millimeter.
IP45

Protected from tools

Protected from low

and small wires

pressure water jets from

greater than 1

any direction.

millimeter.
IP46

Protected from tools

Protected from high

and small wires

pressure water jets from

greater than 1

any direction.

millimeter.
IP47

Protected from tools

Protected from

and small wires

immersion between 15

http://www.dsmt.com/resources/ip-rating-chart/

8/30/2016

IP Rating Chart | DSMT.com

IP
Number

IP48

Page 10 of 19

First Digit - SOLIDS

Second Digit - LIQUIDS

greater than 1

centimeters and 1 meter

millimeter.

in depth.

Protected from tools

Protected from long term

and small wires

immersion up to a

greater than 1

specified pressure.

millimeter.
IP50

IP51

IP52

Protected from limited

Not protected from

dust ingress.

liquids.

Protected from limited

Protected from

dust ingress.

condensation.

Protected from limited

Protected from water

dust ingress.

spray less than 15


degrees from vertical.

IP53

Protected from limited

Protected from water

dust ingress.

spray less than 60


degrees from vertical.

IP54

IP55

Protected from limited

Protected from water

dust ingress.

spray from any direction.

Protected from limited

Protected from low

dust ingress.

pressure water jets from


any direction.

IP56

Protected from limited

Protected from high

dust ingress.

pressure water jets from


any direction.

IP57

Protected from limited

Protected from

dust ingress.

immersion between 15
centimeters and 1 meter
in depth.

IP58

Protected from limited

Protected from long term

dust ingress.

immersion up to a
specified pressure.

IP60

http://www.dsmt.com/resources/ip-rating-chart/

8/30/2016

IP Rating Chart | DSMT.com

IP
Number

IP61

IP62

Page 11 of 19

First Digit - SOLIDS

Second Digit - LIQUIDS

Protected from total

Not protected from

dust ingress.

liquids.

Protected from total

Protected from

dust ingress.

condensation.

Protected from total

Protected from water

dust ingress.

spray less than 15


degrees from vertical.

IP63

Protected from total

Protected from water

dust ingress.

spray less than 60


degrees from vertical.

IP64

IP65

Protected from total

Protected from water

dust ingress.

spray from any direction.

Protected from total

Protected from low

dust ingress.

pressure water jets from


any direction.

IP66

Protected from total

Protected from high

dust ingress.

pressure water jets from


any direction.

IP67

Protected from total

Protected from

dust ingress.

immersion between 15
centimeters and 1 meter
in depth.

IP68

Protected from total

Protected from long term

dust ingress.

immersion up to a
specified pressure.

IP69K

Protected from total

Protected from steam-jet

dust ingress.

cleaning.

References
1. IEC 60529, degrees of Protection Provided by Enclosures (IP Codes), Ed. 2.1 (Geneva:
International Electrotechnical Commision, 2011)
2. IEC 60529 (Ed. 2.1), clause 4.1.

http://www.dsmt.com/resources/ip-rating-chart/

8/30/2016

IP Rating Chart | DSMT.com

IP
Number
IP00

IP01

IP02

Page 12 of 19

First Digit - SOLIDS

Second Digit - LIQUIDS

Not protected from

Not protected from

solids.

liquids.

Not protected from

Protected from

solids.

condensation.

Not protected from

Protected from water

solids.

spray less than 15


degrees from vertical.

IP03

Not protected from

Protected from water

solids.

spray less than 60


degrees from vertical.

IP04

IP05

Not protected from

Protected from water

solids.

spray from any direction.

Not protected from

Protected from low

solids.

pressure water jets from


any direction.

IP06

Not protected from

Protected from high

solids.

pressure water jets from


any direction.

IP07

Not protected from

Protected from

solids.

immersion between 15
centimeters and 1 meter
in depth.

IP08

Not protected from

Protected from long term

solids.

immersion up to a
specified pressure.

IP10

Protected from touch

Not protected from

by hands greater than

liquids.

50 millimeters.
IP11

Protected from touch

Protected from

by hands greater than

condensation.

50 millimeters.
IP12

http://www.dsmt.com/resources/ip-rating-chart/

8/30/2016

IP Rating Chart | DSMT.com

IP
Number

IP13

IP14

Page 13 of 19

First Digit - SOLIDS

Second Digit - LIQUIDS

Protected from touch

Protected from water

by hands greater than

spray less than 15

50 millimeters.

degrees from vertical.

Protected from touch

Protected from water

by hands greater than

spray less than 60

50 millimeters.

degrees from vertical.

Protected from touch

Protected from water

by hands greater than

spray from any direction.

50 millimeters.
IP15

IP16

IP17

Protected from touch

Protected from low

by hands greater than

pressure water jets from

50 millimeters.

any direction.

Protected from touch

Protected from high

by hands greater than

pressure water jets from

50 millimeters.

any direction.

Protected from touch

Protected from

by hands greater than

immersion between 15

50 millimeters.

centimeters and 1 meter


in depth.

IP18

IP20

Protected from touch

Protected from long term

by hands greater than

immersion up to a

50 millimeters.

specified pressure.

Protected from touch

Not protected from

by fingers and objects

liquids.

greater than 12
millimeters.
IP21

Protected from touch

Protected from

by fingers and objects

condensation.

greater than 12
millimeters.
IP22

Protected from touch

Protected from water

by fingers and objects

spray less than 15


degrees from vertical.

http://www.dsmt.com/resources/ip-rating-chart/

8/30/2016

IP Rating Chart | DSMT.com

IP
Number

Page 14 of 19

First Digit - SOLIDS

Second Digit - LIQUIDS

greater than 12
millimeters.
IP23

Protected from touch

Protected from water

by fingers and objects

spray less than 60

greater than 12

degrees from vertical.

millimeters.
IP24

Protected from touch

Protected from water

by fingers and objects

spray from any direction.

greater than 12
millimeters.
IP25

Protected from touch

Protected from low

by fingers and objects

pressure water jets from

greater than 12

any direction.

millimeters.
IP26

Protected from touch

Protected from high

by fingers and objects

pressure water jets from

greater than 12

any direction.

millimeters.
IP27

IP28

Protected from touch

Protected from

by fingers and objects

immersion between 15

greater than 12

centimeters and 1 meter

millimeters.

in depth.

Protected from touch

Protected from long term

by fingers and objects

immersion up to a

greater than 12

specified pressure.

millimeters.
IP30

Protected from tools

Not protected from

and wires greater than

liquids.

2.5 millimeters.
IP31

Protected from tools

Protected from

and wires greater than

condensation.

2.5 millimeters.
IP32

http://www.dsmt.com/resources/ip-rating-chart/

8/30/2016

IP Rating Chart | DSMT.com

IP
Number

IP33

IP34

Page 15 of 19

First Digit - SOLIDS

Second Digit - LIQUIDS

Protected from tools

Protected from water

and wires greater than

spray less than 15

2.5 millimeters.

degrees from vertical.

Protected from tools

Protected from water

and wires greater than

spray less than 60

2.5 millimeters.

degrees from vertical.

Protected from tools

Protected from water

and wires greater than

spray from any direction.

2.5 millimeters.
IP35

IP36

IP37

Protected from tools

Protected from low

and wires greater than

pressure water jets from

2.5 millimeters.

any direction.

Protected from tools

Protected from high

and wires greater than

pressure water jets from

2.5 millimeters.

any direction.

Protected from tools

Protected from

and wires greater than

immersion between 15

2.5 millimeters.

centimeters and 1 meter


in depth.

IP38

IP40

Protected from tools

Protected from long term

and wires greater than

immersion up to a

2.5 millimeters.

specified pressure.

Protected from tools

Not protected from

and small wires

liquids.

greater than 1
millimeter.
IP41

Protected from tools

Protected from

and small wires

condensation.

greater than 1
millimeter.
IP42

Protected from tools

Protected from water

and small wires

spray less than 15


degrees from vertical.

http://www.dsmt.com/resources/ip-rating-chart/

8/30/2016

IP Rating Chart | DSMT.com

IP
Number

Page 16 of 19

First Digit - SOLIDS

Second Digit - LIQUIDS

greater than 1
millimeter.
IP43

Protected from tools

Protected from water

and small wires

spray less than 60

greater than 1

degrees from vertical.

millimeter.
IP44

Protected from tools

Protected from water

and small wires

spray from any direction.

greater than 1
millimeter.
IP45

Protected from tools

Protected from low

and small wires

pressure water jets from

greater than 1

any direction.

millimeter.
IP46

Protected from tools

Protected from high

and small wires

pressure water jets from

greater than 1

any direction.

millimeter.
IP47

IP48

Protected from tools

Protected from

and small wires

immersion between 15

greater than 1

centimeters and 1 meter

millimeter.

in depth.

Protected from tools

Protected from long term

and small wires

immersion up to a

greater than 1

specified pressure.

millimeter.
IP50

IP51

IP52

Protected from limited

Not protected from

dust ingress.

liquids.

Protected from limited

Protected from

dust ingress.

condensation.

Protected from limited

Protected from water

dust ingress.

spray less than 15


degrees from vertical.

http://www.dsmt.com/resources/ip-rating-chart/

8/30/2016

IP Rating Chart | DSMT.com

IP
Number
IP53

Page 17 of 19

First Digit - SOLIDS

Second Digit - LIQUIDS

Protected from limited

Protected from water

dust ingress.

spray less than 60


degrees from vertical.

IP54

IP55

Protected from limited

Protected from water

dust ingress.

spray from any direction.

Protected from limited

Protected from low

dust ingress.

pressure water jets from


any direction.

IP56

Protected from limited

Protected from high

dust ingress.

pressure water jets from


any direction.

IP57

Protected from limited

Protected from

dust ingress.

immersion between 15
centimeters and 1 meter
in depth.

IP58

Protected from limited

Protected from long term

dust ingress.

immersion up to a
specified pressure.

IP60

IP61

IP62

Protected from total

Not protected from

dust ingress.

liquids.

Protected from total

Protected from

dust ingress.

condensation.

Protected from total

Protected from water

dust ingress.

spray less than 15


degrees from vertical.

IP63

Protected from total

Protected from water

dust ingress.

spray less than 60


degrees from vertical.

IP64

IP65

Protected from total

Protected from water

dust ingress.

spray from any direction.

Protected from total


dust ingress.

http://www.dsmt.com/resources/ip-rating-chart/

8/30/2016

IP Rating Chart | DSMT.com

IP
Number

Page 18 of 19

First Digit - SOLIDS

Second Digit - LIQUIDS


Protected from low
pressure water jets from
any direction.

IP66

Protected from total

Protected from high

dust ingress.

pressure water jets from


any direction.

IP67

Protected from total

Protected from

dust ingress.

immersion between 15
centimeters and 1 meter
in depth.

IP68

Protected from total

Protected from long term

dust ingress.

immersion up to a
specified pressure.

IP69K

Protected from total

Protected from steam-jet

dust ingress.

cleaning.

REFERENCES
1. IEC 60529, degrees of Protection Provided by Enclosures (IP Codes), Ed. 2.1
(Geneva: International Electrotechnical Commision, 2011)
2. IEC 60529 (Ed. 2.1), clause 4.1.

For more information on IP Rating please consider the


following links:
IEC 60529 Degrees of protection provided by enclosures (IP Code)
IEC Standards
NEMA Enclosure Ratings
Wikipedia Article IP Code

DISCLAIMER
The information contained in this website is for general information purposes only. The
information is provided by DSM&T Company Inc.and while we endeavour to keep the information
up to date and correct, we make no representations or warranties of any kind, express or implied,
about the completeness, accuracy, reliability, suitability or availability with respect to the website

http://www.dsmt.com/resources/ip-rating-chart/

8/30/2016

IP Rating Chart | DSMT.com

Page 19 of 19

or the information, products, services, or related graphics contained on the website for any
purpose. Any reliance you place on such information is therefore strictly at your own risk.

Want to work with us?


Drop us a line, send us an email, or fill out a form
and lets get started on your project.
Contact

Site Map

Privacy Policy

Patents

Contact Us

2016 DSM&T Co. Inc. All Rights Reserved.