Vous êtes sur la page 1sur 16

SBTS Labeling Standard

Compiled by : OM PRAKASH

Approved by : HEMANT BISHNOI

Label Set Available :-

Labeling instructions for RF Jumpers / Feeder From RF Module to Antenna :Labeling on Jumpers / Feeder between 900 RF Module ( FXJB ) and All three
sectors Antenna
Lable Text

Location

900-SEC1-ANTLN1

From GSM (2G) RF Module to Antenna 1 Feeder MAIN

900-SEC1-ANTLN2

From GSM (2G) RF Module to Antenna 1 Feeder Diversity

900-SEC2-ANTLN1

From GSM (2G) RF Module to Antenna 2 Feeder MAIN

Qty

2
2
2
2
2
2

900-SEC2-ANTLN2 From GSM (2G) RF Module to Antenna 2 Feeder Diversity


900-SEC3-ANTLN1

From GSM (2G) RF Module to Antenna 3 Feeder MAIN

900-SEC3-ANTLN2

From GSM (2G) RF Module to Antenna 3 Feeder Diversity

Labeling on Jumpers / Feeder between 2100 RF Module ( FRGU ) and All


three sectors Antenna
Lable Text

Location

Qty

2100-SEC1-ANTLN1 From WCDMA (3G) RF Module to SEC 1 Antenna Line 1

2
2
2
2
2
2

2100-SEC1-ANTLN2 From WCDMA (3G) RF Module to SEC 1 Antenna Line 2


2100-SEC2-ANTLN1 From WCDMA (3G) RF Module to SEC 2 Antenna Line 1
2100-SEC2-ANTLN2 From WCDMA (3G) RF Module to SEC 2 Antenna Line 2
2100-SEC3-ANTLN1 From WCDMA (3G) RF Module to SEC 3 Antenna LINE 1
2100-SEC3-ANTLN2 From WCDMA (3G) RF Module to SEC 3 Antenna LINE 2

Labeling on Jumpers / Feeder between 1800 RF Module ( FXEF ) and All


three sectors Antenna
Lable Text

Location

1800-SEC1-ANTLN1 From LTE (4G) RF Module to SEC 1 Antenna Line 1


1800-SEC1-ANTLN2 From LTE (4G) RF Module to SEC 1 Antenna Line 2
1800-SEC2-ANTLN1 From LTE (4G) RF Module to SEC 2 Antenna Line 1
1800-SEC2-ANTLN2 From LTE (4G) RF Module to SEC 2 Antenna Line 2
1800-SEC3-ANTLN1 From LTE (4G) RF Module to SEC 3 Antenna LINE 1
1800-SEC3-ANTLN2 From LTE (4G) RF Module to SEC 3 Antenna LINE 2

Qty

2
2
2
2
2
2

Note :-

1) All Labels used must be done in the same


manner i.e. towards the termination point .
2) Label must be same on both the end of the cable
i.e. For every label 2 Quantity of same label
available in Label set .

Labeling instructions for Alarm and GPS Cable :-

Labeling on Alarm and GPS Cable


Lable Text

Location

SRAN FSM-GPS

From System Module of LTE to GPS Antenna

SRAN FSM-ALM

System Module of LTE to Alarm Box/Tag Block

Qty

2
2

Label Text
FR1
FR2
FR3
FR4

Labeling instructions for Optical Cable :Labeling on Optical Cable


Location

Lable Text
SRAN FSM-FR1

From FSMF of GSM (2G) to RF module 900 FXJB Optical cable OPT Port 1

SRAN FSM-FR2

From FSMF of WCDMA (3G) to RF module 2100 FRGU Optical cable OPT Port 1

SRAN FSM-FR3

From FSMF of LTE (4G) to RF module 1800 FXEF 1 Optical cable OPT Port 1

SRAN FSM-FR4

From FSMF of LTE (4G) to RF module 1800 FXEF 2 Optical cable OPT Port 1

Qty

2
2
2
2

Label to be prepared for Optical Cable of 2G 1800 from BLANK Labels


Lable Text

Location

FSM-FR3 -OPT 2

From FSMF of GSM (2G) to RF module 1800 FXEF 1 Optical cable OPT Port 1

FSM-FR4 -OPT 2

From FSMF of GSM (2G) to RF module 1800 FXEF 2 Optical cable OPT Port 2

Qty

2
2

Note :Label symbolize


2G 900 FXJB
3G 2100 FRGU
LTE/2G 1800 FXEF 1
LTE/2G 1800 FXEF 2

Labeling instructions for Transmission Cable :Labeling on Transmission Cable


Location

Lable Text
SRAN FSM-TX

Qty

From Transmission Router/Mux Ethernet to System Module of LTE ( 4G )

Label to be prepared for Transmission Cable of 2G from Blank Labels


Lable Text

Location

FSM- 2G TX 1

From Tx DDF to System Module of GSM ( 2G )- 1st E1

FSM- 2G TX 2

From Tx DDF to System Module of GSM ( 2G )- 2nd E1

FSM- 2G TX 3

From Tx DDF to System Module of GSM ( 2G )- 3rd E1

Qty

2
2
2

Labeling instructions for Power Cables of RF Modules :Labeling on Power Cable of RF Module 900 FXJB - FR1
Location

Lable Text
SRAN FR1-PP

From FSES ( OVP ) to RF module 900 FXJB - AT module end

SRAN FR1-PP

From DCDB to FSES ( OVP ) - At FSES (OVP) End

SRAN FR1-PP

On +ve Cable - At Positive Bus Bar in DCDB

SRAN FR1-PP

On -ve Cable - At MCB End

Qty Total Qty

1
1
1
1

Labeling on Power Cable of RF Module 2100 FRGU - FR2


Location

Lable Text
SRAN FR2-PP

From FSES ( OVP ) to RF module 2100 FRGU - AT module end

SRAN FR2-PP

From DCDB to FSES ( OVP ) - At FSES (OVP) End

SRAN FR2-PP

On +ve Cable - At Positive Bus Bar in DCDB

SRAN FR2-PP

On -ve Cable - At MCB End

Qty Total Qty

1
1
1
1

Labeling on Power Cable of RF Module 1800 FXEF 1 - FR3


Location

Lable Text
SRAN FR3-PP

From FSES ( OVP ) to RF module 1800 FXEF 1 - AT module end

SRAN FR3-PP

From DCDB to FSES ( OVP ) - At FSES (OVP) End

SRAN FR3-PP

On +ve Cable - At Positive Bus Bar in DCDB

SRAN FR3-PP

On -ve Cable - At MCB End

Qty Total Qty

1
1
1
1

Labeling on Power Cable of RF Module 1800 FXEF 2 -FR4


Location

Lable Text
SRAN FR4-PP

From FSES ( OVP ) to RF module 1800 FXEF 2 - AT module end

SRAN FR4-PP

From DCDB to FSES ( OVP ) - At FSES (OVP) End

SRAN FR4-PP

On +ve Cable - At Positive Bus Bar in DCDB

SRAN FR4-PP

On -ve Cable - At MCB End

Qty Total Qty

1
1
1
1

Labeling instructions for Power Cables of System Modules :Labeling to be prepared for Power Cables of 2G , 3G and LTE System Module from Blank
Location
Lable Text
Qty Total Qty
FSM-2G-PP
From DCDB to 2G system Module - AT module end
1
FSM-3G-PP
From DCDB to 3G system Module - AT module end
3
1
FSM-LTE-PP
From DCDB to LTE system Module - AT module end
1

Labeling instructions for Main Power Cables from Power Plant to DCDB :Labeling on Power Cable of DCDB from Power Plant
Lable Text

Location

SRAN FSM-PP

On Main +ve Cable from Power Plant to DCDB

SRAN FSM-PP

On Main -ve Cable from Power Plant to DCDB

Qty Total Qty

2
2

Labeling instructions for Grounding Cables of RF Modules :Labeling on Grounding Cable of RF Modules
Lable Text

Location

Qty

SRAN FR1-GND

From RF module 900 FXJB end to FMFA

SRAN FR2-GND

From RF module 2100 FRGU end to FMFA

SRAN FR3-GND

From RF module 1800 FXEF 1 end to FMFA

SRAN FR4-GND

From RF module 1800 FXEF 2 end to FMFA

2
2
2
2
Label Text
FR1
FR2
FR3
FR4

Note :Label symbolize


2G 900 FXJB
3G 2100 FRGU
LTE/2G 1800 FXEF 1
LTE/2G 1800 FXEF 2

NOKIA Plinth Grounding (FMFA) for RF Modules :-

NOKIA Plinth Grounding (FMFA) for RF Modules


Lable Text

Location

FR2 PLN-GND NOKIA Plinth Grounding (FMFA) for RFM-1 and 2


FR3 PLN-GND

NOKIA Plinth Grounding (FMFA) for RFM-3 and 4

Qty

2
2

Label Text
FR1
FR2
FR3
FR4

Note :Label symbolize


2G 900 FXJB
3G 2100 FRGU
LTE/2G 1800 FXEF 1
LTE/2G 1800 FXEF 2

NOKIA Plinth Grounding (FMFA) for System Modules :-

NOKIA Plinth Grounding (FMFA) for System Modules


Lable Text

Location

Qty

FSM-PLN-GND NOKIA Plinth Grounding (FMFA) for System Module of LTE and 2G

SRAN FSM-GND NOKIA Plinth Grounding (FMFA) for System Module of 3G

Thank You !

Vous aimerez peut-être aussi