Unique Features

Specifications
Model
Cooling Capacity
Power consumption

Indoor

MSF-10CRN1

MSF-13CRN1

MSF-19CRN1

MSF-25CRN1

Outdoor

MOF-10CN1

MOF-13CN1

MOF-19CN1

MOF-25CN1

9500

12500

19000

24000

Rated

Btu/h

Rated

825

1050

1640

2450

4.00

5.00

7.80

11.00

Btu/h/w

10.82

10.92

10.62

9.75

Running current
EER
Energy Efficiency Star Rating
Power supply

Ph-V-Hz

Indoor air flow

m3/h(cfm)

560 (330)

610 (360)

800 (470)

1000 (618)

dB(A)

40/30

42/31

44/33

47/41

Indoor Sound level (H/L)

Indoor unit

Base
e Pan
Outdoor unit

Dimension(W*D*H)

mm

800x188x275

800x188x275

940x205x275

1045x235x315

Packing (W*D*H)

mm

865x265x350

865x265x350

1015x265x350

1135x395x315

Net/Gross weight

Kg

7.8 / 9.8

8.0 / 10.0

10 / 13.2

12.6 / 16

Outdoor air flow

m3/h(cfm)

1650 (970)

1900 (1118)

2500 (1470)

2700 (1588)

Outdoor Sound level

dB(A)

54

56

58

60

Dimension(W*D*H)

mm

700x240x540

780x250x540

845x320x700

845x320x700

Packing (W*D*H)

mm

815x325x580

910x335x585

965x395x755

965x395x755

Net/Gross weight

Kg

24/26

28 / 31.5

42 / 46

47 / 50

Refrigerant Charge

R410A/530g

R410A/810g

R410A//1050g

R410A//1350g

MPa

4.2/1.5

4.2/1.5

4.2/1.5

4.2/1.5

Design pressure

Integrated Design

Liquid side/ Gas side

Outlet Pan
Air O

New Integrated Structure


Ne

Conventional Structure

Ionizer

Refrigerant piping

220-240V~ 50Hz, 1Ph

mm(inch)

6.35/9.52(1/4"/3/8")

6.35/12.7(1/4"/1/2")

6.35/12.7(1/4"/1/2")

9.52/15.9(3/8"/5/8")

Max. refrigerant pipe length

20

20

25

25

Max. difference in level

10

10

Remark:
1.The above design and specifications are subject to change of product improvement without prior notice.
2.The noise level data reflects the level in anechoic chamber .

Release negative ions, eliminate odor, dust, smoke and


pollen particles to give you fresh and healthy air.

Sleep Mode
The function enables the air conditioner to automatically
increase 1 C per hour for the first two hoursthen holds
steady for the next 5 hours, after that it will switch off.
This function maintains both energy saving and comfort
in the night.

Midea Scott & English Electronics Sdn Bhd (194517-X)


No. 16, Jalan Chan Sow Lin, 55200 Kuala Lumpur Tel: 03-9221 1033
Fax: 03-9221 7204 / 03-9221 1434 / 03-9221 3509

Butterworth

Kuantan

19, Jalan Perai Jaya 4, Bandar Perai Jaya,


13600 Perai, Pulau Pinang
Tel: 04-397 2288 Fax: 04-397 2828

A-261, Mezzanine Floor, Jalan Beserah,


25300 Kuantan, Pahang.
Tel: 09-560 6668 Fax: 09-560 6668

Johor Bahru

Sabah

No. 25, Jalan Seri Impian 1, Taman Impian Emas,


81300 Skudai, Johor
Tel: 07-562 4898 Fax: 07-557 7898

Lot22, 1st Floor, Beverly Hills Industry Park,


Penampang, Sabah.
Tel: 088-722 544 Fax: 088-722 544

Sarawak
Malacca
385-L, Taman Peringgit Jaya, 75400 Peringgit, Melaka.
Tel: 06-292 1940 Fax: 06-286 7107

1st Floor , Lot 8517, Stutong Commercial Centre,


Jalan Stutong, 93350 Kuching, Sarawak
Tel: 082-363 167 Fax: 082-366 167

Dealers Stamp:

Midea Malaysia

www.midea.com/my

Wall Mounted

Fairwind split
Integrative Design

Base pan and air outlet pan assembly adopt integrated


design for easy installation and maintenance.

Louver Position Memory Function

Refrigerant Leakage Detection

When you start the unit, the angle of horizontal louver


will automatically move to the same position as you set
previously.

With this new technology, the indoor unit will alarm


when the refrigerant leakage reach to a certain level
amount to protect the compressor.

Fresco Tech

Features

Mideas Fresco Tech brings you clean and refreshing air fills your room with the soothing scent of nature.

VC

HEALTH

RELIABILITY

Silver Ion Filter

Refrigerant Leakage Detect

The silver ion can kill bacteria or prevent their


activity at very low density by destroying their
inner-configuration and absorbing their
elements in cells.

With this new technology, the indoor unit will


alarm when the outdoor unit detects a
condition of refrigerant leakage.

Cold Catalyst Filter

BLUE FIN Condenser

Eliminate formaldehyde and other volatile


organic compounds (VOCs) as well as harmful
gases and odors.

Anti-corrosive epoxy coating improves the


heat exchangers from corrosion and thus
ensures durability and improves efficiency
and higher energy savings.

VC
VC

Previous Air-Flow Angle

2-Ways Piping Connection

i-Memory (Short cut)

Both left and right sides of the indoor unit are possible
for outstretch of connective piping and drainage hose.

With this button you can preset all the parameters, such
as temperature, operation mode, fan speed and etc.

1
When you press the
i-MEMORY (SHORT
CUT) button, the unit
will run the pre-recorded
mode and no need to
reset the parameters.

Blue Fin Condenser

The built-in temperature sensor in the remote controller


will sense its surrounding temperature. So the unit can
adjust room temperature more accurately to give you
more comfort.

Anti-corrosive epoxy coating improves the heat


exchangers from corrosion and thus ensures durability
and improves efficiency and higher energy savings.

Silver Ion Filter

Bio Filter

The silver ion can kill bacteria or prevent their


activity at very low density by destroying
their inner-configuration and absorbing their
elements in cells.

Consist of specialized biological enzyme,


fungi and HEPA filter.
filter Catch small dust
particles, bacteria, microbe, eliminate
bacteria by dissolving their cell wall.

Bio Filter
Consist of specialized biological enzyme,
fungi and HEPA filter. Catch small dust
particles, bacteria, microbe, eliminate bacteria
by dissolving their cell wall.

Ionizer

2
Follow Me

Cold Catalyst Filter

Ionizer

Eliminate formaldehyde and other volatile


organic compounds (VOCs) as well as
harmful gases and odors.

Release negative ions, eliminate odor, dust,


smoke and pollen particles to give you fresh
and healthy air.

Release negative ions, eliminate odor, dust,


smoke and pollen particles to give you fresh
and healthy air.

ENERGY SAVING
Sleep Mode
The function enables the air conditioner to
automatically increase 1 C per hour for the
first two hoursthen holds steady for the next 5
hours, after that it will switch off. This function
maintains both energy saving and comfort in
the night.

CONVENINCE
Self-Cleaning
When this function is activated, the indoor
unit operates under Fan mode with low fan
speed initially. The fan will gradually blows
away the condensed water and dust on the
evaporator. This process will keep the
evaporator clean and dry at all time.

Remote Control

Louver Position Memory Function


When you start the unit, the angle of
horizontal louver will automatically move to
the same position as you set previously.

Auto-Restart
If the air conditioner breaks off unexpectedly
due to the power cut, it will restart with the
previous function setting automatically when
the power resumes.

Temperature Setting
ON / OFF

Conventional temperature
sensor location

Mode Setting

The Follow Me temperature sensor


is build-in the remote controller

AUTO/COOL/DRY/FAN

i-Memory (Short Cut)


Function
RESUME PREVIOUS SETTING

COMFORT
Follow Me

Turbo Mode

Self-Cleaning

With this function, the air conditioner will maximize the


output of cooling capacity to cool down the room and
attain the desired temperature in the shortest time.

When this function is activated, the indoor unit operates


under Fan mode with low fan speed initially. The fan
will gradually blows away the condensed water and dust
on the evaporator. This process will keep the evaporator
clean and dry at all time.

Timer Setting
Fan Speed Setting
HIGH/MED/LOW/AUTO

Sleep Mode
Ionizer

Turbo / Selfclean

With this technology, a temperature sensor is


built in the remote control. When you stay
close to the remote controll, the unit will
automatically change the operation mode to
supply comfortable temperature just like the
air conditioner is following you.

Air Flow: Swing / Direct


Turbo Operation

LED Display
/ Follow Me

With this function, the air conditioner will


maximize the output of cooling capacity to
cool down the room and attain the desired
temperature in the shortest time.

2 Ways Piping Connection


Both left and right sides of the indoor unit are
possible for outstretch of connective piping
and drainage hose.

Louver Position Memory Function

Refrigerant Leakage Detection

When you start the unit, the angle of horizontal louver


will automatically move to the same position as you set
previously.

With this new technology, the indoor unit will alarm


when the refrigerant leakage reach to a certain level
amount to protect the compressor.

Fresco Tech

Features

Mideas Fresco Tech brings you clean and refreshing air fills your room with the soothing scent of nature.

VC

HEALTH

RELIABILITY

Silver Ion Filter

Refrigerant Leakage Detect

The silver ion can kill bacteria or prevent their


activity at very low density by destroying their
inner-configuration and absorbing their
elements in cells.

With this new technology, the indoor unit will


alarm when the outdoor unit detects a
condition of refrigerant leakage.

Cold Catalyst Filter

BLUE FIN Condenser

Eliminate formaldehyde and other volatile


organic compounds (VOCs) as well as harmful
gases and odors.

Anti-corrosive epoxy coating improves the


heat exchangers from corrosion and thus
ensures durability and improves efficiency
and higher energy savings.

VC
VC

Previous Air-Flow Angle

2-Ways Piping Connection

i-Memory (Short cut)

Both left and right sides of the indoor unit are possible
for outstretch of connective piping and drainage hose.

With this button you can preset all the parameters, such
as temperature, operation mode, fan speed and etc.

1
When you press the
i-MEMORY (SHORT
CUT) button, the unit
will run the pre-recorded
mode and no need to
reset the parameters.

Blue Fin Condenser

The built-in temperature sensor in the remote controller


will sense its surrounding temperature. So the unit can
adjust room temperature more accurately to give you
more comfort.

Anti-corrosive epoxy coating improves the heat


exchangers from corrosion and thus ensures durability
and improves efficiency and higher energy savings.

Silver Ion Filter

Bio Filter

The silver ion can kill bacteria or prevent their


activity at very low density by destroying
their inner-configuration and absorbing their
elements in cells.

Consist of specialized biological enzyme,


fungi and HEPA filter.
filter Catch small dust
particles, bacteria, microbe, eliminate
bacteria by dissolving their cell wall.

Bio Filter
Consist of specialized biological enzyme,
fungi and HEPA filter. Catch small dust
particles, bacteria, microbe, eliminate bacteria
by dissolving their cell wall.

Ionizer

2
Follow Me

Cold Catalyst Filter

Ionizer

Eliminate formaldehyde and other volatile


organic compounds (VOCs) as well as
harmful gases and odors.

Release negative ions, eliminate odor, dust,


smoke and pollen particles to give you fresh
and healthy air.

Release negative ions, eliminate odor, dust,


smoke and pollen particles to give you fresh
and healthy air.

ENERGY SAVING
Sleep Mode
The function enables the air conditioner to
automatically increase 1 C per hour for the
first two hoursthen holds steady for the next 5
hours, after that it will switch off. This function
maintains both energy saving and comfort in
the night.

CONVENINCE
Self-Cleaning
When this function is activated, the indoor
unit operates under Fan mode with low fan
speed initially. The fan will gradually blows
away the condensed water and dust on the
evaporator. This process will keep the
evaporator clean and dry at all time.

Remote Control

Louver Position Memory Function


When you start the unit, the angle of
horizontal louver will automatically move to
the same position as you set previously.

Auto-Restart
If the air conditioner breaks off unexpectedly
due to the power cut, it will restart with the
previous function setting automatically when
the power resumes.

Temperature Setting
ON / OFF

Conventional temperature
sensor location

Mode Setting

The Follow Me temperature sensor


is build-in the remote controller

AUTO/COOL/DRY/FAN

i-Memory (Short Cut)


Function
RESUME PREVIOUS SETTING

COMFORT
Follow Me

Turbo Mode

Self-Cleaning

With this function, the air conditioner will maximize the


output of cooling capacity to cool down the room and
attain the desired temperature in the shortest time.

When this function is activated, the indoor unit operates


under Fan mode with low fan speed initially. The fan
will gradually blows away the condensed water and dust
on the evaporator. This process will keep the evaporator
clean and dry at all time.

Timer Setting
Fan Speed Setting
HIGH/MED/LOW/AUTO

Sleep Mode
Ionizer

Turbo / Selfclean

With this technology, a temperature sensor is


built in the remote control. When you stay
close to the remote controll, the unit will
automatically change the operation mode to
supply comfortable temperature just like the
air conditioner is following you.

Air Flow: Swing / Direct


Turbo Operation

LED Display
/ Follow Me

With this function, the air conditioner will


maximize the output of cooling capacity to
cool down the room and attain the desired
temperature in the shortest time.

2 Ways Piping Connection


Both left and right sides of the indoor unit are
possible for outstretch of connective piping
and drainage hose.

Louver Position Memory Function

Refrigerant Leakage Detection

When you start the unit, the angle of horizontal louver


will automatically move to the same position as you set
previously.

With this new technology, the indoor unit will alarm


when the refrigerant leakage reach to a certain level
amount to protect the compressor.

Fresco Tech

Features

Mideas Fresco Tech brings you clean and refreshing air fills your room with the soothing scent of nature.

VC

HEALTH

RELIABILITY

Silver Ion Filter

Refrigerant Leakage Detect

The silver ion can kill bacteria or prevent their


activity at very low density by destroying their
inner-configuration and absorbing their
elements in cells.

With this new technology, the indoor unit will


alarm when the outdoor unit detects a
condition of refrigerant leakage.

Cold Catalyst Filter

BLUE FIN Condenser

Eliminate formaldehyde and other volatile


organic compounds (VOCs) as well as harmful
gases and odors.

Anti-corrosive epoxy coating improves the


heat exchangers from corrosion and thus
ensures durability and improves efficiency
and higher energy savings.

VC
VC

Previous Air-Flow Angle

2-Ways Piping Connection

i-Memory (Short cut)

Both left and right sides of the indoor unit are possible
for outstretch of connective piping and drainage hose.

With this button you can preset all the parameters, such
as temperature, operation mode, fan speed and etc.

1
When you press the
i-MEMORY (SHORT
CUT) button, the unit
will run the pre-recorded
mode and no need to
reset the parameters.

Blue Fin Condenser

The built-in temperature sensor in the remote controller


will sense its surrounding temperature. So the unit can
adjust room temperature more accurately to give you
more comfort.

Anti-corrosive epoxy coating improves the heat


exchangers from corrosion and thus ensures durability
and improves efficiency and higher energy savings.

Silver Ion Filter

Bio Filter

The silver ion can kill bacteria or prevent their


activity at very low density by destroying
their inner-configuration and absorbing their
elements in cells.

Consist of specialized biological enzyme,


fungi and HEPA filter.
filter Catch small dust
particles, bacteria, microbe, eliminate
bacteria by dissolving their cell wall.

Bio Filter
Consist of specialized biological enzyme,
fungi and HEPA filter. Catch small dust
particles, bacteria, microbe, eliminate bacteria
by dissolving their cell wall.

Ionizer

2
Follow Me

Cold Catalyst Filter

Ionizer

Eliminate formaldehyde and other volatile


organic compounds (VOCs) as well as
harmful gases and odors.

Release negative ions, eliminate odor, dust,


smoke and pollen particles to give you fresh
and healthy air.

Release negative ions, eliminate odor, dust,


smoke and pollen particles to give you fresh
and healthy air.

ENERGY SAVING
Sleep Mode
The function enables the air conditioner to
automatically increase 1 C per hour for the
first two hoursthen holds steady for the next 5
hours, after that it will switch off. This function
maintains both energy saving and comfort in
the night.

CONVENINCE
Self-Cleaning
When this function is activated, the indoor
unit operates under Fan mode with low fan
speed initially. The fan will gradually blows
away the condensed water and dust on the
evaporator. This process will keep the
evaporator clean and dry at all time.

Remote Control

Louver Position Memory Function


When you start the unit, the angle of
horizontal louver will automatically move to
the same position as you set previously.

Auto-Restart
If the air conditioner breaks off unexpectedly
due to the power cut, it will restart with the
previous function setting automatically when
the power resumes.

Temperature Setting
ON / OFF

Conventional temperature
sensor location

Mode Setting

The Follow Me temperature sensor


is build-in the remote controller

AUTO/COOL/DRY/FAN

i-Memory (Short Cut)


Function
RESUME PREVIOUS SETTING

COMFORT
Follow Me

Turbo Mode

Self-Cleaning

With this function, the air conditioner will maximize the


output of cooling capacity to cool down the room and
attain the desired temperature in the shortest time.

When this function is activated, the indoor unit operates


under Fan mode with low fan speed initially. The fan
will gradually blows away the condensed water and dust
on the evaporator. This process will keep the evaporator
clean and dry at all time.

Timer Setting
Fan Speed Setting
HIGH/MED/LOW/AUTO

Sleep Mode
Ionizer

Turbo / Selfclean

With this technology, a temperature sensor is


built in the remote control. When you stay
close to the remote controll, the unit will
automatically change the operation mode to
supply comfortable temperature just like the
air conditioner is following you.

Air Flow: Swing / Direct


Turbo Operation

LED Display
/ Follow Me

With this function, the air conditioner will


maximize the output of cooling capacity to
cool down the room and attain the desired
temperature in the shortest time.

2 Ways Piping Connection


Both left and right sides of the indoor unit are
possible for outstretch of connective piping
and drainage hose.

Unique Features

Specifications
Model
Cooling Capacity
Power consumption

Indoor

MSF-10CRN1

MSF-13CRN1

MSF-19CRN1

MSF-25CRN1

Outdoor

MOF-10CN1

MOF-13CN1

MOF-19CN1

MOF-25CN1

9500

12500

19000

24000

Rated

Btu/h

Rated

825

1050

1640

2450

4.00

5.00

7.80

11.00

Btu/h/w

10.82

10.92

10.62

9.75

Running current
EER
Energy Efficiency Star Rating
Power supply

Ph-V-Hz

Indoor air flow

m3/h(cfm)

560 (330)

610 (360)

800 (470)

1000 (618)

dB(A)

40/30

42/31

44/33

47/41

Indoor Sound level (H/L)

Indoor unit

Base
e Pan
Outdoor unit

Dimension(W*D*H)

mm

800x188x275

800x188x275

940x205x275

1045x235x315

Packing (W*D*H)

mm

865x265x350

865x265x350

1015x265x350

1135x395x315

Net/Gross weight

Kg

7.8 / 9.8

8.0 / 10.0

10 / 13.2

12.6 / 16

Outdoor air flow

m3/h(cfm)

1650 (970)

1900 (1118)

2500 (1470)

2700 (1588)

Outdoor Sound level

dB(A)

54

56

58

60

Dimension(W*D*H)

mm

700x240x540

780x250x540

845x320x700

845x320x700

Packing (W*D*H)

mm

815x325x580

910x335x585

965x395x755

965x395x755

Net/Gross weight

Kg

24/26

28 / 31.5

42 / 46

47 / 50

Refrigerant Charge

R410A/530g

R410A/810g

R410A//1050g

R410A//1350g

MPa

4.2/1.5

4.2/1.5

4.2/1.5

4.2/1.5

Design pressure

Integrated Design

Liquid side/ Gas side

Outlet Pan
Air O

New Integrated Structure


Ne

Conventional Structure

Ionizer

Refrigerant piping

220-240V~ 50Hz, 1Ph

mm(inch)

6.35/9.52(1/4"/3/8")

6.35/12.7(1/4"/1/2")

6.35/12.7(1/4"/1/2")

9.52/15.9(3/8"/5/8")

Max. refrigerant pipe length

20

20

25

25

Max. difference in level

10

10

Remark:
1.The above design and specifications are subject to change of product improvement without prior notice.
2.The noise level data reflects the level in anechoic chamber .

Release negative ions, eliminate odor, dust, smoke and


pollen particles to give you fresh and healthy air.

Sleep Mode
The function enables the air conditioner to automatically
increase 1 C per hour for the first two hoursthen holds
steady for the next 5 hours, after that it will switch off.
This function maintains both energy saving and comfort
in the night.

Midea Scott & English Electronics Sdn Bhd (194517-X)


No. 16, Jalan Chan Sow Lin, 55200 Kuala Lumpur Tel: 03-9221 1033
Fax: 03-9221 7204 / 03-9221 1434 / 03-9221 3509

Butterworth

Kuantan

19, Jalan Perai Jaya 4, Bandar Perai Jaya,


13600 Perai, Pulau Pinang
Tel: 04-397 2288 Fax: 04-397 2828

A-261, Mezzanine Floor, Jalan Beserah,


25300 Kuantan, Pahang.
Tel: 09-560 6668 Fax: 09-560 6668

Johor Bahru

Sabah

No. 25, Jalan Seri Impian 1, Taman Impian Emas,


81300 Skudai, Johor
Tel: 07-562 4898 Fax: 07-557 7898

Lot22, 1st Floor, Beverly Hills Industry Park,


Penampang, Sabah.
Tel: 088-722 544 Fax: 088-722 544

Sarawak
Malacca
385-L, Taman Peringgit Jaya, 75400 Peringgit, Melaka.
Tel: 06-292 1940 Fax: 06-286 7107

1st Floor , Lot 8517, Stutong Commercial Centre,


Jalan Stutong, 93350 Kuching, Sarawak
Tel: 082-363 167 Fax: 082-366 167

Dealers Stamp:

Midea Malaysia

www.midea.com/my

Wall Mounted

Fairwind split
Integrative Design

Base pan and air outlet pan assembly adopt integrated


design for easy installation and maintenance.

Unique Features

Specifications
Model
Cooling Capacity
Power consumption

Indoor

MSF-10CRN1

MSF-13CRN1

MSF-19CRN1

MSF-25CRN1

Outdoor

MOF-10CN1

MOF-13CN1

MOF-19CN1

MOF-25CN1

9500

12500

19000

24000

Rated

Btu/h

Rated

825

1050

1640

2450

4.00

5.00

7.80

11.00

Btu/h/w

10.82

10.92

10.62

9.75

Running current
EER
Energy Efficiency Star Rating
Power supply

Ph-V-Hz

Indoor air flow

m3/h(cfm)

560 (330)

610 (360)

800 (470)

1000 (618)

dB(A)

40/30

42/31

44/33

47/41

Indoor Sound level (H/L)

Indoor unit

Base
e Pan
Outdoor unit

Dimension(W*D*H)

mm

800x188x275

800x188x275

940x205x275

1045x235x315

Packing (W*D*H)

mm

865x265x350

865x265x350

1015x265x350

1135x395x315

Net/Gross weight

Kg

7.8 / 9.8

8.0 / 10.0

10 / 13.2

12.6 / 16

Outdoor air flow

m3/h(cfm)

1650 (970)

1900 (1118)

2500 (1470)

2700 (1588)

Outdoor Sound level

dB(A)

54

56

58

60

Dimension(W*D*H)

mm

700x240x540

780x250x540

845x320x700

845x320x700

Packing (W*D*H)

mm

815x325x580

910x335x585

965x395x755

965x395x755

Net/Gross weight

Kg

24/26

28 / 31.5

42 / 46

47 / 50

Refrigerant Charge

R410A/530g

R410A/810g

R410A//1050g

R410A//1350g

MPa

4.2/1.5

4.2/1.5

4.2/1.5

4.2/1.5

Design pressure

Integrated Design

Liquid side/ Gas side

Outlet Pan
Air O

New Integrated Structure


Ne

Conventional Structure

Ionizer

Refrigerant piping

220-240V~ 50Hz, 1Ph

mm(inch)

6.35/9.52(1/4"/3/8")

6.35/12.7(1/4"/1/2")

6.35/12.7(1/4"/1/2")

9.52/15.9(3/8"/5/8")

Max. refrigerant pipe length

20

20

25

25

Max. difference in level

10

10

Remark:
1.The above design and specifications are subject to change of product improvement without prior notice.
2.The noise level data reflects the level in anechoic chamber .

Release negative ions, eliminate odor, dust, smoke and


pollen particles to give you fresh and healthy air.

Sleep Mode
The function enables the air conditioner to automatically
increase 1 C per hour for the first two hoursthen holds
steady for the next 5 hours, after that it will switch off.
This function maintains both energy saving and comfort
in the night.

Midea Scott & English Electronics Sdn Bhd (194517-X)


No. 16, Jalan Chan Sow Lin, 55200 Kuala Lumpur Tel: 03-9221 1033
Fax: 03-9221 7204 / 03-9221 1434 / 03-9221 3509

Butterworth

Kuantan

19, Jalan Perai Jaya 4, Bandar Perai Jaya,


13600 Perai, Pulau Pinang
Tel: 04-397 2288 Fax: 04-397 2828

A-261, Mezzanine Floor, Jalan Beserah,


25300 Kuantan, Pahang.
Tel: 09-560 6668 Fax: 09-560 6668

Johor Bahru

Sabah

No. 25, Jalan Seri Impian 1, Taman Impian Emas,


81300 Skudai, Johor
Tel: 07-562 4898 Fax: 07-557 7898

Lot22, 1st Floor, Beverly Hills Industry Park,


Penampang, Sabah.
Tel: 088-722 544 Fax: 088-722 544

Sarawak
Malacca
385-L, Taman Peringgit Jaya, 75400 Peringgit, Melaka.
Tel: 06-292 1940 Fax: 06-286 7107

1st Floor , Lot 8517, Stutong Commercial Centre,


Jalan Stutong, 93350 Kuching, Sarawak
Tel: 082-363 167 Fax: 082-366 167

Dealers Stamp:

Midea Malaysia

www.midea.com/my

Wall Mounted

Fairwind split
Integrative Design

Base pan and air outlet pan assembly adopt integrated


design for easy installation and maintenance.

Vous aimerez peut-être aussi