Vous êtes sur la page 1sur 80

Patchset Incorporation

Siemens

-Register-Dat ei

Patchset Incorporation

Objectives
The participant is able to
 describe the SW procedures for the patchset incorporation
 describe the different ways to incorporate patchsets into the system
 handle problems during patchset incorporation with high reliability
 name and evaluate the symptom files in case of the CMD- file control interruption

Contents
1
1.1
1.2
2
2.1
2.2
2.3
2.4
3
3.1
3.2
3.3

Patchset Incorporation
Testing of Patches
Ways of Patchset Incorporation
Procedures for Patch Incorporation
Procedure Steps for Standard Patches
Procedure Steps for FEPROM Patches
Important Notes for the Incorporation of Patchsets
Overview of Tool Supported Elements
Exception Handling
Defined Interruption of the CMD-File Control
Undefined Interruption of the CMD-File Control
Conventions

SN2040E6A01

3
5
6
13
14
15
16
27
29
30
59
77

Siemens

Patchset Incorporation

SN2040E6A01

Patchset Incorporation

Siemens

1 Patchset Incorporation

SN2040E6A01

Siemens

Patchset Incorporation

SN2040E6A01

Patchset Incorporation

Siemens

1.1 Testing of Patches


Before patches are distributed to the NEs, they are tested several times by different
departments.

TA C 3

Siem ens central service

generation of

SSG

Patch Procedure in Service

project specific

(on m ainfram e)

delivery units

logical steps

(patchsets)

S oftw are

TA C 2

C onfiguration
M anagem ent
S ystem

Siem ens local service

delivery
of
patchsets

delivery
of
patchsets
and
optional
generation
of patch
docum entation

and
optional
generation
of patch
docum entation

status / inventory
record keeping

status / inventory
record keeping

C ASIN O

TA C 1
custom er

incorporation
of
patchsets
update
of patch
docum entation
status / inventory
record keeping

A utopatch: N C /C T

Fig. 1

Fig. 2

SN2040E6A01

Patchset Incorporation

Siemens

1.2 Ways of Patchset Incorporation


1.2.1 Manually with MOD (or TAPE)
1

SIEME NS
NIX DORF

TACO

CASINO

CF.MF.
PA.

OR

SIEME NS
NIX DORF

TSC

CMD - files
on Tape:

CMD - files
on MOD:

Patchset (File: .SAM)


Patchset documentation
(on paper)

SIEME NS
NIX DORF

CF.MF.
PA.

WINDISKUS

Read patchset documentation and incorporation


instruction. See 2.3 Important notes.

APS saving if necessary (normal saving intervals


according to the APS saving concept).

Patch comparison (manually).

Check number of free F1 labels (manually).

Fig. 3

SN2040E6A01

Patchset Incorporation

Siemens

Transfer CMD - files to


the MDDs.
CMD - files on MDD:
CF.MF.
PA.

OR

Prepare the Network Element:

Patchset incorporation:

Follow the patch incorporation instruction (!)


and the MMN:SW 411, SW 412. E.g.: enter
different STAT commands, inhibit RT and SSA,
test CP units (in case of FEPROM patches).

Start CF.MF. - files manually


(EXECCMDFILE command).

Incorporation successful:

If necessary: special actions according


to the patch incorporation instruction
and MMN:SW 411 / 412. E.g.: initiate
NSTART1, test CP units (in case of
FEPROM patches).

10

Clean up the system:

Incorporation unsuccessful:

Exception handling,
see 3 Exception handling.

Allow RT and SSA.


Delete CF.MF.- and PA.- files.
....(and more
MMN:SW 411 / 412).

Fig. 4

SN2040E6A01

Patchset Incorporation

Siemens

1.2.2 Automatically with AutoPatch (Preferred Way)


1

ISDN, ftp, email, floppy.


SIEMENS
NIXDORF

SIEMENS
NIXDO RF

TSC

CASINO

Patchset, including
patchset documentation
(File: .dps)

Read patchset documentation and incorporation


instruction. See 2.3 Important notes.

APS saving if necessary (normal saving intervals


according to the APS saving concept).

Patch comparison (automatically with AutoPatch).

Check number of free F1 labels (automatically).

AutoPatch (light or
NodeCommander
or OMC-S)

Fig. 5

SN2040E6A01

Patchset Incorporation

Siemens

Transfer CMD - files to


the MDDs.

X25

SIEMENS
NI XDORF

CMD - files
on MDD:
PM.
MF.
PA.

AutoPatch (light or
NodeCommander
or OMC-S)
Prepare the Network Element:

Follow the patch incorporation instruction (!),


MMN:SW 411 / 412 and the UMN: AutoPatch.
E.g.: enter different STAT commands, inhibit RT
and SSA, test CP units (in case of FEPROM
patches).

Patchset incorporation

(automatically with AutoPatch).

Incorporation successful:

Incorporation unsuccessful:

If necessary: special actions according to


the patch incorporation instruction, MMN:
SW 411 / 412 and UMN: AutoPatch.
E.g.: initiate NSTART1, test CP units (in
case of FEPROM patches).

10

Clean up the system:

Exception handling,
see 3 Exception handling.

Allow RT and SSA.


....(and more
MMN:SW 411 / 412).

Fig. 6

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

SN2040E6A01

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

Patchset Incorporation

Siemens

1.2.3 Comparison of AutoPatch and MOD Delivery

Advantages

Variant 1

Variant 2

Variant 3

MOD delivery

AUTOPATCH

AUTOPATCH

Incorporated by
Customer

Incorporated by
Customer

Incorporated by
Siemens

Electronic delivery
of the patchsets

As in Variant 2
and additionally:

Automatic
 No investment
incorporation
by customer
without presence of
personnel in the NE  No customer
know-how
 Short running times
required.
 Electronic delivery
of the patch
documentation with
the patchset


10

Automatic return of
the SW inventory
data

Improved data
security

Work does not


increase in direct
proportion to
network growth

SN2040E6A01

Patchset Incorporation

Disadvantages

SN2040E6A01

Siemens

Variant 1

Variant 2

Variant 3

MOD delivery

AUTOPATCH

AUTOPATCH

Incorporated by
Customer

Incorporated by
Customer

Incorporated by
Siemens

More personnel
required

Presence of
 investment required
personnel required in
(HW/SW)
the NE

No automatic SW
inventory record
keeping

Lengthily running
times for
incorporation in all
NEs

Work increases in
direct proportion to
network growth

Customer knowhow required

11

Siemens

12

Patchset Incorporation

SN2040E6A01

Patchset Incorporation

Siemens

2 Procedures for Patch Incorporation

SN2040E6A01

13

Patchset Incorporation

Siemens

2.1 Procedure Steps for Standard Patches


The procedure contains steps controlled by the AutoPatch Manager and steps
initiated via MML- commands for NE preparation, status of units and configuration
functions.
Step

Function

APS saving on MDD (according to the APS saving concept)

Patch comparison - AutoPatch

Patch transfer - AutoPatch

Status CCNC (if CCNC patches)

Status CP units

Inhibit Routine Test and System Status Analysis

Patch incorporation - AutoPatch

Allow Routine Test and System Status Analysis

The successful execution of every step is verified by evaluation of the MML


command execution and the task manager protocol of AutoPatch.
WARNING
The patch incorporation instructions contain additional information on the handling of
a specific patch (e.g. NSTART 1).

14

SN2040E6A01

Patchset Incorporation

Siemens

2.2 Procedure Steps for FEPROM Patches


The procedure contains steps controlled by the AutoPatch Manager and steps
initiated via MML- commands for NE preparation, status of units, test of units, flash
of units and configuration functions.
Step

Function

APS saving on MDD (according to the APS saving concept)

Patch comparison - AutoPatch

Patch transfer - AutoPatch

Status CP units

Test CP units (and repair faulty units)

Inhibit Routine Test and System Status Analysis

Patch incorporation - AutoPatch

Test CP units (starts reprogramming FEPROMs)

Allow Routine Test and System Status Analysis

The successful execution of every step is verified by evaluation of the MML


command execution and the task manager protocol of AutoPatch.
WARNING
The patch incorporation instructions contain additional information on the handling of
a specific patch (e.g. NSTART 1 or patch to clear faults in a test program).

SN2040E6A01

15

Siemens

Patchset Incorporation

2.3 Important Notes for the Incorporation of


Patchsets
WARNING
The following important notes must be regarded:

16

Before executing this procedure the delivered patch documentation must be read
to consider possible special cases of patch incorporation (e.g. patch to clear fault
in test program). The patch documentation also contains information about the
effects of the patches.

All previous patch revisions have had to be inserted successfully.

Only patches that have been released by the responsible Siemens departments
may be incorporated. Corrections prepared by the system personnel at the site of
the system are not allowed!

Patch incorporation is to be done under low call processing load.

During patch incorporation no configuration commands for CCNC, LTG, and CP


should be executed.

Normally patch files contain the command for increasing the APS version number
by 1.

The incorporation instruction, delivered with the patchset are to be followed


strictly.

SN2040E6A01

Patchset Incorporation

Siemens

2.3.1 Example of a Patchset Documentation


Patchset Delivery Report
-----------------------Project short name
APS name
Patchset number

99-01-18 , 15:53:15.6

: CTY
: CTYCPZ1V1150
: 066

The patchset consists of following revisions to be incorporated


in mandatory ascending order as shown in the list below.
Please do not change the delivered revisions. It may cause
severe problems.
Incorporation procedure dependencies and hardware/firmware
dependencies of revisions are shown close to the corresponding
revisions. These revisions and the corresponding incorporation
procedure description are framed with stars.
Revision list
------------Function
-----------

Part-APS
------------

Ltyp
----

LTGC

CNIHBA3N1150

003

A350

43

0012

LTGB:DLU

CNIHBC2N1151

022

C251

51

0018

LTGB:V52

CNIHBF2N1150

052

F250

50

0026

LTGH

CNIHBG0N1150

060

G050

38

0005

CP113

WOMXBZ1V1150

000

Z150

69

0021

CP113

WOMXBZ1V1150

000

Z150

70

0002

LTGB:DLU

CNIHBC2N1151

022

C251

52

0001

LTGH

CNIHBG0N1150

060

G050

39

0001

LTGB:V52

CNIHBF2N1150

052

F250

51

0001

SN2040E6A01

rev.#
-----

number Patches
--------------

17

Siemens

Patchset Incorporation

IOP:UNI >= UNICBQ0V1131 121


Q031
06
0001
******************************************************************
* Begin of revision with incorporation procedure: SPECIAL_ACTION *
*
*
*
Before or after incorporation of revision following
*
*
special actions have to be performed.
*
*
*
*
Please note: The description of the special action(s)
*
*
below possibly contains redundant or multiple
*
*
occuring information, because this is only the
*
*
dependency text sequence of all the patches included
*
*
in the revision.
*
*
*
* *** Incorporation procedure of patch X5299L7Z0001
*
* The system should run with two active disks.
* EXECCMDFILE for Patch
* To flash the IOPUNI's, the TESTIOP command has to entered twice
* for each IOPUNI.
*
*
TESTIOP:IOP=IOPUNI-0;
** IOPUNI runs now out of back-uppart
*
TESTIOP:IOP=IOPUNI-0;
** IOPUNI runs now from system-part
*
*
TESTIOP:IOP=IOPUNI-1;
** IOPUNI runs now out of back-uppart
*
TESTIOP:IOP=IOPUNI-1;
** IOPUNI runs now from system-part
*
*
* Incorporation of revision:
*-------------------------------------------------------------*
*CP113
WOMXBZ1V1150 000
Z150
71
0001
*-------------------------------------------------------------*
*
*
* End of revision with incorporation procedure: SPECIAL_ACTION
*
******************************************************************
---------------------------------------------------------------------The patchset contains 11 revisions with totally 89 patches.
---------------------------------------------------------------------Please obey the following common incorporation procedures:
- Please make sure there is no SSP routine test running during
incorporation of CP113 revisions.
- Enter INHIBSSPRT before incorporation of CP113 revisions.
- Enter ALLOWSSPRT after incorporation of CP113 revisions.
- Enter ACT MDDAUDIT : TYPE=ACTUAL after successful incorporation
of the patchset to start the MDD-AUDIT for the actual generation.

18

SN2040E6A01

Patchset Incorporation

Siemens

Appendix 1: Reference list: errornumber / patchid / customer


for APS: CTYCPZ1V1150 patchset 066
Patchids which are not concerned a customer error of the delivered
project are signed with 'COMMON' instead of the errornumber.
GP-Patches are listed only once (GP-Masterpatchname)
error #
-------

Patch-Id
------------

COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON

W3268L4DA0A0
X0011L4DA0A0
X1956L4DA0A0
W1207L4KA0A0
X1642L4DA0A0
W4599L4DA0A0
W6385L4DA0A0
W8352L4DA0A0
X3962L4DA0A0
X5625L4DA0A0
W9887L4DA0A0
X2412L4DA0A0
X3403L4DA0A0
X4286L4DA0A0
X5584L4DA0A0
X6362L4DA0A0
D8509L4KA0A0
D0992L2Z0001
V4650L2Z0002
W1752L2Z0001
W7997L2Z0001
X0398L2Z0003
X2794L2Z0001
X3533L2Z0001
X5381L2Z0001
X9061L2Z0001
X5198L2Z0001
X6052L2Z0001
W8442L2Z0001
X2502L3Z0001

customer
-----------

error #
-------

Patch-Id
------------

COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON
COMMON

W5115L4KA0A0
X1305L4DA0A0
X3171L4DA0A0
X7669L4DA0A0
W4598L4DA0A0
W9885L4DA0A0
W6499L4DA0A0
X2082L4DA0A0
X4942L4DA0A0
W9886L4DA0A0
X2415L4DA0A0
X3169L4DA0A0
X0569L4DA0A0
X4943L4DA0A0
V5899L4KA0A0
X2031L4DA0A0
D8510L4KA0A0
H2946L2Z0001
V9529L2Z0002
W4166L2Z0001
X0041L2Z0001
W1717L2Z0001
W3418L2Z0001
W4775L2Z0001
W3677L2Z0001
X5197L2Z0001
X5200L2Z0001
W8533L2Z0001
W5211L4DA0A0
X5299L7Z0001

customer
-----------

Appendix 2: Status 08 report of APS: CTYCPZ1V1150 from


patchset 000 up to actual delivered patchset 066
The following patches have been set to status 08.
They were delivered and are active in your system.
Backout (and if existing) replace patches will be
delivered as soon as available.
If the following table is empty no status 08
patches are active in your system.
Patchid
------------

SN2040E6A01

Revision
--------

Function
--------------------

19

Siemens

Patchset Incorporation

2.3.2 Example: Result of a Patch Comparison Run


Task Manager (ASWTASK) V304.01 Reportlist Printout
----------------------------------------------------------------------Installation name : R34851
Function
: NE Action: Generation of Files
Start Function
: 99.08.05 - 12:12:34
GENFILES: + function started => TaskID: 2922
GENFILES: + generation complete
End
Function
: 99.08.05 - 12:12:35
***** Patch Action (ASWINC) V304.01
***** Copyright (c) SIEMENS AG 1998
----------------------------------------------------------------------Installation name : R34851
Function
: OS action: dlm22
Start Function
: 99.08.05 - 12:13:45
NE HANDLER: + OS file transfer: dlm22
NE HANDLER: + Put file(s)
NE HANDLER: + Transfer is running!
NE HANDLER: + Atop started with UNIX PID: 6207
NE HANDLER: + OS transfer successful!
NE HANDLER: ++ Starting next action:
***** Patch Action (ASWINC) V304.01
***** Copyright (c) SIEMENS AG 1998
----------------------------------------------------------------------Installation name : R34851
Function
: NE action: dlm22
Start Function
: 99.08.05 - 12:15:21
AICOM: + Start command file
AICOM: + User - nevoigt3 / NE - dlm22(DBPCBZ0V1241)
AICOM: + Authentication
AICOM: + Session established
AICOM: DISPTIME;
AICOM: + Command accepted
AICOM: + Command executed
AICOM: + NE date - 99-08-05 / NE time - 12:17:17
AICOM: + NE APS - DBPCBZ0V1241-P41/410
AICOM: EXECCMDFILE:FILE=eb.dlm22;
AICOM: + Command accepted
AICOM: + NE job number: 703
***** Patch Action (ASWINC) V304.01
***** Copyright (c) SIEMENS AG 1998
----------------------------------------------------------------------Installation name : R34851
Function
: NE action: dlm22
Start Function
: 99.08.05 - 12:16:37
AICOM: + Display Job
AICOM: + User - nevoigt3 / NE - dlm22(DBPCBZ0V1241)
AICOM: + Authentication
AICOM: + Session established
AICOM: DISPJOB:JN=703;
AICOM: + Command accepted
AICOM: + Command executed
AICOM: + Last job check: 12:18:32
AICOM: + NE job: running
***** Patch Action (ASWINC) V304.01
***** Copyright (c) SIEMENS AG 1998
-----------------------------------------------------------------------

20

SN2040E6A01

Patchset Incorporation

Siemens

Installation name : R34851


Function
: NE action: dlm22
Start Function
: 99.08.05 - 12:21:52
AICOM: + Display Job
AICOM: + User - nevoigt3 / NE - dlm22(DBPCBZ0V1241)
AICOM: + Authentication
AICOM: + Session established
AICOM: DISPJOB:JN=703;
AICOM: + Command accepted
AICOM: + Command executed
AICOM: + Last job check: 12:23:47
AICOM: + NE job: running
***** Patch Action (ASWINC) V304.01
***** Copyright (c) SIEMENS AG 1998
----------------------------------------------------------------------Installation name : R34851
Function
: NE action: dlm22
Start Function
: 99.08.05 - 12:27:10
AICOM: + Display Job
AICOM: + User - nevoigt3 / NE - dlm22(DBPCBZ0V1241)
AICOM: + Authentication
AICOM: + Session established
AICOM: DISPJOB:JN=703;
AICOM: + Command accepted
AICOM: + Command executed
AICOM: + Last job check: 12:29:04
AICOM: + NE job: running
AICOM: ! NE job: EXECCMDFILE:FILE=EB.DLM22; - No event
***** Patch Action (ASWINC) V304.01
***** Copyright (c) SIEMENS AG 1998
----------------------------------------------------------------------Installation name : R34851
Function
: NE action: dlm22
Start Function
: 99.08.05 - 12:32:24
AICOM: + Display Job
AICOM: + User - nevoigt3 / NE - dlm22(DBPCBZ0V1241)
AICOM: + Authentication
AICOM: + Session established
AICOM: DISPJOB:JN=703;
AICOM: + Command accepted
AICOM: + Command executed
AICOM: + NE job: finished
***** Patch Action (ASWINC) V304.01
***** Copyright (c) SIEMENS AG 1998
----------------------------------------------------------------------Installation name : R34851
Function
: OS action: dlm22
Start Function
: 99.08.05 - 12:33:41
NE HANDLER: + OS file transfer: dlm22
NE HANDLER: + Get file(s)
NE HANDLER: + Transfer is running!
NE HANDLER: + Atop started with UNIX PID: 6591
NE HANDLER: + History file received!
NE HANDLER: ++ Starting next action:
-----------------------------------------------------------------------

SN2040E6A01

21

Patchset Incorporation

Siemens

Installation name
Function
Start Function

: R34851
: Run Comparison
: 99.08.05 - 12:37:49

Patch Comparison 3.06


Net Element
SW System

: TESTANLAGE
: DBPCBZ0V1241

PART SYSTEM STATUS


==================
Load
Part System
SSGItem
Unit
Type Status
---------------------------------------------------------------DBPHBC2N1232 DBP12C232 GP:LTGB
022
active
DBPHBC3N1231 DBP12C331 GP:LTGC
023
active
DBPHBC4N1231 DBP12C431 GP:LTGA
024
active
DBPHBF0N1231 DBP12F031 GP:LTGD
050
active
DBPHBF2N1232 DBP12F232 GP:LTGB
052
active
DBPHBG0N1231 DBP12G031 GP:LTGH
060
active
I7SZBJ7N1203 DBP12J703 CCNC:CPI
097
active
P7SZBJ8N1203 DBP12J803 CCNC:SIMP
098
active
UNICBQ0V1131 DBP12Q031 IOP:UNI
121
active
X25CBQ1V1130 DBP12Q130 IOP:SCDP
100
active
DBPXBZ0V1240 DBP12Z040 CP
000
active

RESULT OF PATCH COMPARISON


==========================
Total Patch Stock (DB)
Patchset
Part System Rev. Function
Unit
------------------------------E23 (M01)
DBPHBG0N1231 23 GP:LTGH
DBPXBZ0V1240 23 CP
E26 (M01)
DBPXBZ0V1240 26 CP
E28 (M01)
DBPXBZ0V1240 28 CP
E36 (M01)
DBPHBC2N1232 36 GP:LTGB
DBPHBC3N1231 36 GP:LTGC
DBPHBF2N1232 36 GP:LTGB
DBPXBZ0V1240 36 CP
E37 (M01)
DBPHBC2N1232 37 GP:LTGB
DBPHBC3N1231 37 GP:LTGC
DBPHBC4N1231 37 GP:LTGA
DBPHBF0N1231 37 GP:LTGD
DBPHBF2N1232 37 GP:LTGB
DBPHBG0N1231 37 GP:LTGH
DBPXBZ0V1240 37 CP




22

Actual Patch Stock (NE)


Incorporation
Status
----------------------==> complete
==> complete
==> complete
==> complete
==>
==>
==>
==>

complete
complete
complete
complete

==>
==>
==>
==>
==>
==>
==>

complete
complete
complete
complete
complete
complete
complete

SN2040E6A01

Patchset Incorporation

Siemens

L18 (M51)
DBPHBC2N1232 K8 GP:LTGB
==> complete
DBPHBC3N1231 K8 GP:LTGC
==> complete
DBPHBF2N1232 K8 GP:LTGB
==> complete
L19 (M52)
DBPXBZ0V1240 K9 CP
==> complete
L20 (M53)
DBPXBZ0V1240 L0 CP
==> partly
V1400L2J0001 Back-out Patch with unknown Forward Patch
L21 (M60)
DBPHBC2N1232 L1 GP:LTGB
==> complete
DBPHBC4N1231 L1 GP:LTGA
==> complete
DBPHBF2N1232 L1 GP:LTGB
==> complete
L22 (M69)
DBPHBC2N1232 L2 GP:LTGB
==> complete
L23 (M70)
DBPXBZ0V1240 L3 CP
==> complete
L24 (M71)
DBPHBC2N1232 L4 GP:LTGB
==> complete
DBPHBC3N1231 L4 GP:LTGC
==> complete
DBPHBC4N1231 L4 GP:LTGA
==> complete
DBPHBF0N1231 L4 GP:LTGD
==> complete
DBPHBF2N1232 L4 GP:LTGB
==> complete
DBPHBG0N1231 L4 GP:LTGH
==> complete
L25 (M82)
DBPHBC3N1231 L5 GP:LTGC
==> complete
DBPXBZ0V1240 L5 CP
==> complete
L26 (
) not incorporated
L27 (
) not incorporated
N01 (M01)
DBPHBC2N1232 01 GP:LTGB
==> complete
DBPHBC3N1231 01 GP:LTGC
==> complete
DBPHBC4N1231 01 GP:LTGA
==> complete
DBPHBF0N1231 01 GP:LTGD
==> complete
DBPHBF2N1232 01 GP:LTGB
==> complete
DBPHBG0N1231 01 GP:LTGH
==> complete
UNICBQ0V1131 01 IOP:UNI
==> complete
X25CBQ1V1130 01 IOP:SCDP
==> complete
N02 (M01) completely removed by Back-out Patch(es)
N03 (M01)
UNICBQ0V1131 03 IOP:UNI
==> complete
N04 (M01)
UNICBQ0V1131 04 IOP:UNI
==> complete
N05 (M01) completely removed by Back-out Patch(es)
N06 (M01)
UNICBQ0V1131 06 IOP:UNI
==> complete
N07 (M01)
DBPHBC2N1232 07 GP:LTGB
==> complete
DBPHBC3N1231 07 GP:LTGC
==> complete
DBPHBC4N1231 07 GP:LTGA
==> complete
DBPHBF0N1231 07 GP:LTGD
==> complete
DBPHBF2N1232 07 GP:LTGB
==> complete
DBPHBG0N1231 07 GP:LTGH
==> complete



N74 (M18)
DBPHBC2N1232 74 GP:LTGB
==> complete
DBPHBC3N1231 74 GP:LTGC
==> complete
DBPHBC4N1231 74 GP:LTGA
==> complete
SN2040E6A01

23

Patchset Incorporation

Siemens

DBPHBF0N1231 74 GP:LTGD
DBPHBF2N1232 74 GP:LTGB
DBPHBG0N1231 74 GP:LTGH
DBPXBZ0V1240 74 CP
APSLMY00.V8395L7Z.0001.0 is
N75 (M19)
DBPXBZ0V1240 75 CP



P28 (M75)
DBPHBC2N1232 C8 GP:LTGB
DBPHBC3N1231 C8 GP:LTGC
DBPHBC4N1231 C8 GP:LTGA
DBPXBZ0V1240 C8 CP
P29 (M76)
DBPHBC2N1232 C9 GP:LTGB
DBPHBC4N1231 C9 GP:LTGA
P30 (M78) not incorporated
P31 (M79) not incorporated
P32 (M80)
DBPHBC2N1232 D2 GP:LTGB
DBPHBC3N1231 D2 GP:LTGC
DBPHBC4N1231 D2 GP:LTGA
DBPHBG0N1231 D2 GP:LTGH
DBPXBZ0V1240 D2 CP
P33 (M81)
P7SZBJ8N1203 D3 CCNC:SIMP
P34 (M77)
DBPXBZ0V1240 D4 CP
P35 (M83)
DBPHBC2N1232 D5 GP:LTGB
C3739L4J0002 Back-out Patch
T022@@@@.Y8906L4Z.0005.0 is
T022@@@@.Y1642L4Z.0002.0 is
T022@@@@.Y3097L4Z.0002.0 is
T022@@@@.Y4809L4Z.0005.0 is
T022@@@@.Y8611L4Z.0005.0 is
T022@@@@.Y9444L4Z.0002.0 is
T022@@@@.Y9444L4Z.0002.1 is
T022@@@@.Y9445L4Z.0002.0 is
T022@@@@.Y9531L4Z.0002.0 is
T022@@@@.Z0063L4Z.0002.0 is
DBPHBC3N1231 D5 GP:LTGC
T023@@@@.Y1642L4Z.0003.0 is
T023@@@@.Y9531L4Z.0003.0 is
T023@@@@.Z0063L4Z.0003.0 is
DBPHBC4N1231 D5 GP:LTGA
T024@@@@.Y1642L4Z.0004.0 is
T024@@@@.Y4809L4Z.0006.0 is
T024@@@@.Y9531L4Z.0004.0 is
DBPHBF0N1231 D5 GP:LTGD
T050@@@@.Y1642L4Z.0005.0 is
T050@@@@.Y9531L4Z.0005.0 is
DBPHBG0N1231 D5 GP:LTGH
T060@@@@.Y3097L4Z.0003.0 is
T060@@@@.Y8611L4Z.0006.0 is
T060@@@@.Y9531L4Z.0006.0 is
DBPXBZ0V1240 D5 CP
APSLMY00.Y8409L2Z.0001.0 is

24

==> complete
==> complete
==> complete
==> partly
missing (free format patch)
==> complete

==>
==>
==>
==>

complete
complete
complete
complete

==> complete
==> complete

==>
==>
==>
==>
==>

complete
complete
complete
complete
complete

==> complete
==> complete
==> partly
not incorporated
missing
missing
missing
missing
missing
missing
missing
missing
missing
missing
==> is missing
missing
missing
missing
==> is missing
missing
missing
missing
==> is missing
missing
missing
==> is missing
missing
missing
missing
==> is missing
missing
SN2040E6A01

Patchset Incorporation

Siemens

APSLMY00.Y9355L2Z.0001.0 is missing
APSLMY00.Y9915L2Z.0001.0 is missing
APSLMY00.Y9917L2Z.0001.0 is missing
APSLMY00.Z0034L2Z.0001.0 is missing
P36 (P36) not incorporated
P37 (P37) not incorporated
P38 (
)
DBPHBC2N1232 D8 GP:LTGB
==> complete
DBPHBC3N1231 D8 GP:LTGC
==> complete
DBPHBC4N1231 D8 GP:LTGA
==> complete
DBPHBF0N1231 D8 GP:LTGD
==> complete
DBPHBG0N1231 D8 GP:LTGH
==> complete
P39 (
) not incorporated
P40 (M88)
DBPHBC2N1232 E0 GP:LTGB
==> complete
DBPHBC3N1231 E0 GP:LTGC
==> complete
DBPHBC4N1231 E0 GP:LTGA
==> complete
DBPHBF0N1231 E0 GP:LTGD
==> complete
DBPHBG0N1231 E0 GP:LTGH
==> complete
DBPXBZ0V1240 E0 CP
==> complete
P41 (P41)
DBPHBC2N1232 E1 GP:LTGB
==> complete
DBPHBC3N1231 E1 GP:LTGC
==> complete
DBPHBG0N1231 E1 GP:LTGH
==> complete
DBPXBZ0V1240 E1 CP
==> complete
P42 (M90) not incorporated
P44 (P44) not incorporated
P45 (
) not incorporated
S04 (S04)
DBPHBC2N1232 W4 GP:LTGB
==> complete
DBPHBF2N1232 W4 GP:LTGB
==> complete
S05 (S05)
DBPHBC3N1231 W5 GP:LTGC
==> complete
S06 (S06)
DBPHBC2N1232 W6 GP:LTGB
==> not updated on Disk
Y9574L4Z0006 Patch not updated on Disk (ENTREG)

***** WARNING *****


Following Patchsets incorporated in NE but not released in Database
(possible incorrect Patch Comparison!):
Patchset
-------------N17 (M01)
N18 (M01)
N19 (M01)
N20 (M01)
N21 (M01)



P28 (M75)
P29 (M76)
P33 (M81)
P34 (M77)
P35 (M83)
P38 (
)
P41 (P41)
S06 (S06)

SN2040E6A01

25

Patchset Incorporation

Siemens

SUMMARY
=======
Patchset |No. Rev.|complete| partly |not upd.|not exist|released
-----------+--------+--------+--------+--------+---------+---------E23 (M01) |
2 |
2 |
0 |
0 |
0
|
Y
E26 (M01) |
1 |
1 |
0 |
0 |
0
|
Y
E28 (M01) |
1 |
1 |
0 |
0 |
0
|
Y
E36 (M01) |
4 |
4 |
0 |
0 |
0
|
Y
E37 (M01) |
7 |
7 |
0 |
0 |
0
|
Y



P28 (M75) |
4 |
4 |
0 |
0 |
0
|
N
P29 (M76) |
2 |
2 |
0 |
0 |
0
|
N
P30 (M78) |
4 |
- |
- |
- |
|
N
P31 (M79) |
4 |
- |
- |
- |
|
N
P32 (M80) |
5 |
5 |
0 |
0 |
0
|
Y
P33 (M81) |
1 |
1 |
0 |
0 |
0
|
N
P34 (M77) |
1 |
1 |
0 |
0 |
0
|
N
P35 (M83) |
6 |
0 |
1 |
0 |
5
|
N
P36 (P36) |
7 |
- |
- |
- |
|
N
P37 (P37) |
5 |
- |
- |
- |
|
N
P38 (
) |
5 |
5 |
0 |
0 |
0
|
N
P39 (
) |
4 |
- |
- |
- |
|
N
P40 (M88) |
6 |
6 |
0 |
0 |
0
|
Y
P41 (P41) |
4 |
4 |
0 |
0 |
0
|
N
P42 (M90) |
2 |
- |
- |
- |
|
N
P44 (P44) |
4 |
- |
- |
- |
|
Y
P45 (
) |
4 |
- |
- |
- |
|
Y
S04 (S04) |
2 |
2 |
0 |
0 |
0
|
Y
S05 (S05) |
1 |
1 |
0 |
0 |
0
|
Y
S06 (S06) |
1 |
0 |
0 |
1 |
0
|
N

Following Patch IDs does not exist in Database but in History File:
Patch-ID
------------------------------T121@@@@.X5871L7Z.0001.0
APSLMY00.V2278L2Z.0001.0

STATISTIC
=========
Total Modifications for SW System
Total Patch-Ids in all Modifications
Total Back-Out Patch-Ids in all Modifications
Total Patch-Ids in History File
Patch-Ids in History File but not in Database
Patch-Ids in Database but not in History File

:
:
:
:
:
:

146
5831
304
5095
2
29

Function succsessful
End
Function
: 99.08.05 - 13:09

26

SN2040E6A01

Patchset Incorporation

Siemens

2.4 Overview of Tool Supported Elements


The incorporation of patches can be executed local with patch supply on MOD/MTD
or remote from OMC-S using Autopatch (automated patch supply).
The Autopatch procedure in the OMC-S allows


fast distribution of software corrections using electronic media,

incorporation of software corrections without presence of staff in the network


element,

reliable monitoring of the patch distribution.

Prerequisites of the Autopatch procedure are described in UMN:Autopatch. The


tasks of this patch software procedure are identical for patching with or without
Autopatch.
Tool supported elements are shown in the following overview table.
Task

without AutoPatch
Standard
patches

FEPROM
patches

with Autopatch
Standard
patches

FEPROM
patches

APS saving

SW 210

SW 210

Patch comparison

SW 411

UMN: AutoPatch "Comparing


patches"

Patch transfer

SW 411

UMN: AutoPatch "Transferring the


Patch Set to the NE"

Preparation

SW 411

SW 412

SW 411

SW 412

Patch incorporation SW 411

SW 412

UMN: AutoPatch
"Incorporation the
Patch Set on the
NE"

UMN: AutoPatch
"Incorporation
the Patch Set on
the NE"
SW 412

Clean up the
system

SN2040E6A01

SW 411

SW 412

SW 411

SW 412

27

Siemens

28

Patchset Incorporation

SN2040E6A01

Patchset Incorporation

Siemens

3 Exception Handling

SN2040E6A01

29

Siemens

Patchset Incorporation

3.1 Defined Interruption of the CMD-File Control


Situation:
Predefined, known error messages of the CMD- file occurs.
defined interruption of the CMD- file control.
System state:
It is guaranteed, that the individual patches are incorporated either completely or not
at all.
Error diagnosis:
Indications for


error place and

kind of error

are available as the order of events of the CMD- file and can be evaluated.
Symptom files: PT., MLOG.
Additional error information: AutoPatch task manager protocol.
Error correction:
Immediate action (if possible):
Fallback for patchset (AutoPatch ENM 3.2)
After a completed evaluation of the indications:
Classification of the error and initiate measurements to remove the error:


Is one patch (of the patchset) already incorporated ?


call next TAC level.

Is there another patch at the same patch address ?


call next TAC level.

Faulty patch ?
call next TAC level.

30

SN2040E6A01

Patchset Incorporation

Siemens

3.1.1 Structure of CMD-Files


Patchset:

File:

Patch:

File:

073

PM.CTY11.K50.P073

01
02
03
:

PA.W1189L2Z.V0001
PA.X4283L2Z.V0001
PA.W6377L2Z.V0002
:

Patch:

File:

01

PA.Y1924L2Z.V0001

Patch:

File:

01
02
03
:

PA.V3839L4Z.V0054
PA.W2109L4Z.V0002
PA.W4921L4Z.V0002
:

Revision:

File:

01

PA.Y4800L3Z.V0001

(Primary Master file)

PM starts MF files

MF starts PA files

Revision:

File:

CP 75
CP 76
LTG 56
IOP 09

MF.CTY11.Z15075
MF.CTY11.Z15076
MF.CTY11.C25156
MF.CTY11.Q03109
(Master File)

Fig. 7

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

SN2040E6A01

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

31

Siemens

Patchset Incorporation

Definitions:


Patch package:
All Patches necessary to solve one defect.

Revision:
Patch amount to be inserted without interrupt (part- APS specific).

Patchset:
Delivery unit, including one or more revisions.

32

SN2040E6A01

Patchset Incorporation

3.1.1.1

Siemens

PM-File Example

<CMDFILE;
/* PM.CTY11.K50.P073
<SET CFOPT:DANCMD=EXEC,ACKREQ=POS,ACKCFS=ERROR,OFF=16;
<ACT OUTDIV:FILE=PT.CTY11.K50.P073,MODE=CR,SIZE=100,ACKCF=ERROR;
<SKIP CMD: LABEL=ERROR,ON=32;
//
********************************************************
//
** PATCHSET RELEASED AT: 1999.05.04 12:27
**
//
**
**
//
**
STARTED
**
//
** PRIMARY MASTERFILE : PM.CTY11.K50.P073 GESTARTET **
//
**
ARRANCADO **
//
**
**
//
********************************************************
/*
<EXECCMDFILE:FILE=MF.CTY11.Z15075;
<SKIP CMD: LABEL=ERROR,ON=32;
<SKIP CMD: LABEL=ERROR,ON=16;
<EXECCMDFILE:FILE=MF.CTY11.Z15076;
<SKIP CMD: LABEL=ERROR,ON=32;
<SKIP CMD: LABEL=ERROR,ON=16;
<EXECCMDFILE:FILE=MF.CTY11.C25156;
<SKIP CMD: LABEL=ERROR,ON=32;
<SKIP CMD: LABEL=ERROR,ON=16;
<EXECCMDFILE:FILE=MF.CTY11.Q03108;
<SKIP CMD: LABEL=ERROR,ON=32;
<SKIP CMD: LABEL=ERROR,ON=16;
<EXECCMDFILE:FILE=MF.CTY11.Z15077;
<SKIP CMD: LABEL=ERROR,ON=32;
<SKIP CMD: LABEL=ERROR,ON=16;
<EXECCMDFILE:FILE=MF.CTY11.Q03109;
<SKIP CMD: LABEL=ERROR,ON=32;
<SKIP CMD: LABEL=ERROR,ON=16;
/*
//
**********************************************
//
**
**
//
** PRIMARY MASTERFILE : PM.CTY11.K50.P073 **
//
**
**
//
**
SUCCESSFULLY PROCESSED
**
//
** MASTERFILES ERFOLGREICH AUSGEFUEHRT
**
//
**
PROCESADO EXITOSO
**
//
**
**
//
**********************************************
/*
//
********************************************************
//
**
**
//
**
PRIMARY MASTERFILE : PM.CTY11.K50.P073
**
//
**
**
//
** DELETION OF PATCHFILES AND MASTERFILES
STARTED
**
//
** LOESCHEN VON PATCHFILES UND MASTERFILES GESTARTET **
//
** CANCELADO DE PATCHFILES Y MASTERFILES
ARRANCADO **
//
**
**
//
********************************************************
/*
<DELFILE:FILE=PA.W1189L2Z.V0001;
<DELFILE:FILE=PA.W6377L2Z.V0002;
<DELFILE:FILE=PA.X4283L2Z.V0001;
<DELFILE:FILE=PA.X7316L2Z.V0001;

SN2040E6A01

33

Siemens

Patchset Incorporation

<DELFILE:FILE=PA.X9157L2Z.V0001;
<DELFILE:FILE=PA.E7040L2J.V0001;
<DELFILE:FILE=PA.X9418L2Z.V0001;
<DELFILE:FILE=PA.Y1652L2Z.V0002;
<DELFILE:FILE=PA.Y0011L2Z.V0001;
<DELFILE:FILE=PA.W2833L2J.V0001;
<DELFILE:FILE=PA.Y0648L2Z.V0001;



<DELFILE:FILE=PA.Y3513L4Z.V0039;
<DELFILE:FILE=PA.W1584L4Z.V0055;
<DELFILE:FILE=PA.Y1555L4Z.V0053;
<DELFILE:FILE=PA.W7666L4Z.V0077;
<DELFILE:FILE=PA.Y2431L4Z.V0053;
<DELFILE:FILE=PA.Y3660L4Z.V0055;
<DELFILE:FILE=PA.Y3279L4Z.V0026;
<DELFILE:FILE=PA.Y4792L4Z.V0043;
<DELFILE:FILE=PA.Y5090L4Z.V0022;
<DELFILE:FILE=PA.Y6092L4Z.V0007;
<DELFILE:FILE=PA.Y0504L3Z.V0001;
<DELFILE:FILE=PA.X6829L2Z.V0003;
<DELFILE:FILE=PA.Y0424L2Z.V0003;
<DELFILE:FILE=PA.Y4800L3Z.V0001;
<DELFILE:FILE=MF.CTY11.Z15075;
<DELFILE:FILE=MF.CTY11.Z15076;
<DELFILE:FILE=MF.CTY11.C25156;
<DELFILE:FILE=MF.CTY11.Q03108;
<DELFILE:FILE=MF.CTY11.Z15077;
<DELFILE:FILE=MF.CTY11.Q03109;
/*
//
********************************************************
//
**
**
//
**
PRIMARY MASTERFILE : PM.CTY11.K50.P073
**
//
**
**
//
** DELETION OF PATCHFILES AND MASTERFILES FINISHED
**
//
** LOESCHEN VON PATCHFILES UND MASTERFILES BEENDET
**
//
** CANCELADO DE PATCHFILES Y MASTERFILES
FINALIZADO **
//
**
**
//
********************************************************
/*
<RESET CFOPT;
<DEC OUTDIV;
<ENDFILE;
/*
.ERROR <SET CFOPT:OFF=16;
//
**********************************************
//
**
**
//
**
PRIMARY MASTERFILE : PM.CTY11.K50.P073 **
//
**
**
//
**
ABORTED
**
//
**
ABGEBROCHEN
**
//
**
ABORTADO
**
//
**
**
//
**********************************************
<RESET CFOPT;
<DEC OUTDIV;
<ENDFILE;

34

SN2040E6A01

Patchset Incorporation

3.1.1.2

Siemens

MF-File Example

CMDFILE;
/* MF.CTY11.Z15075
<SET CFOPT:DANCMD=EXEC,ACKREQ=POS,ACKCFS=ERROR,OFF=16;
//
**********************************************
//
** PATCHSET RELEASED AT: 1999.05.04 12:27
**
//
**
**
//
**
STARTED
**
//
** MASTERFILE : MF.CTY11.Z15075 GESTARTET **
//
**
ARRANCADO **
//
** LOADTYPE
:
**
//
**
**
//
**********************************************
/*
<EXECCMDFILE:FILE=PA.W1189L2Z.V0001,STEP;
<SKIP CMD: LABEL=ERROR,ON=32;
<SKIP CMD: LABEL=ERROR,ON=16;
<EXECCMDFILE:FILE=PA.W6377L2Z.V0002,STEP;
<SKIP CMD: LABEL=ERROR,ON=32;
<SKIP CMD: LABEL=ERROR,ON=16;
<EXECCMDFILE:FILE=PA.X4283L2Z.V0001,STEP;
<SKIP CMD: LABEL=ERROR,ON=32;
<SKIP CMD: LABEL=ERROR,ON=16;
<EXECCMDFILE:FILE=PA.X7316L2Z.V0001,STEP;
<SKIP CMD: LABEL=ERROR,ON=32;
<SKIP CMD: LABEL=ERROR,ON=16;
<EXECCMDFILE:FILE=PA.X9157L2Z.V0001,STEP;
<SKIP CMD: LABEL=ERROR,ON=32;
<SKIP CMD: LABEL=ERROR,ON=16;
<EXECCMDFILE:FILE=PA.E7040L2J.V0001,STEP;
<SKIP CMD: LABEL=ERROR,ON=32;
<SKIP CMD: LABEL=ERROR,ON=16;
<EXECCMDFILE:FILE=PA.X9418L2Z.V0001,STEP;
<SKIP CMD: LABEL=ERROR,ON=32;
<SKIP CMD: LABEL=ERROR,ON=16;
<EXECCMDFILE:FILE=PA.Y1652L2Z.V0002,STEP;
<SKIP CMD: LABEL=ERROR,ON=32;
<SKIP CMD: LABEL=ERROR,ON=16;
<EXECCMDFILE:FILE=PA.Y0011L2Z.V0001,STEP;
<SKIP CMD: LABEL=ERROR,ON=32;
<SKIP CMD: LABEL=ERROR,ON=16;
<EXECCMDFILE:FILE=PA.W2833L2J.V0001,STEP;
<SKIP CMD: LABEL=ERROR,ON=32;
<SKIP CMD: LABEL=ERROR,ON=16;
<EXECCMDFILE:FILE=PA.Y0648L2Z.V0001,STEP;
<SKIP CMD: LABEL=ERROR,ON=32;
<SKIP CMD: LABEL=ERROR,ON=16;
<EXECCMDFILE:FILE=PA.Y0280L2Z.V0001,STEP;
<SKIP CMD: LABEL=ERROR,ON=32;
<SKIP CMD: LABEL=ERROR,ON=16;
<EXECCMDFILE:FILE=PA.Y0649L2Z.V0001,STEP;
<SKIP CMD: LABEL=ERROR,ON=32;
<SKIP CMD: LABEL=ERROR,ON=16;
<EXECCMDFILE:FILE=PA.Y0650L2Z.V0001,STEP;
<SKIP CMD: LABEL=ERROR,ON=32;
<SKIP CMD: LABEL=ERROR,ON=16;
<EXECCMDFILE:FILE=PA.Y0711L2Z.V0001,STEP;
<SKIP CMD: LABEL=ERROR,ON=32;

SN2040E6A01

35

Siemens

Patchset Incorporation

<SKIP CMD: LABEL=ERROR,ON=16;


<EXECCMDFILE:FILE=PA.Y0777L2Z.V0002,STEP;
<SKIP CMD: LABEL=ERROR,ON=32;
<SKIP CMD: LABEL=ERROR,ON=16;
<EXECCMDFILE:FILE=PA.Y1403L2Z.V0004,STEP;
<SKIP CMD: LABEL=ERROR,ON=32;
<SKIP CMD: LABEL=ERROR,ON=16;
<EXECCMDFILE:FILE=PA.Y2371L2Z.V0001,STEP;
<SKIP CMD: LABEL=ERROR,ON=32;
<SKIP CMD: LABEL=ERROR,ON=16;
<EXECCMDFILE:FILE=PA.Y4976L2Z.V0001,STEP;
<SKIP CMD: LABEL=ERROR,ON=32;
<SKIP CMD: LABEL=ERROR,ON=16;
<EXECCMDFILE:FILE=PA.Y5130L2Z.V0001,STEP;
<SKIP CMD: LABEL=ERROR,ON=32;
<SKIP CMD: LABEL=ERROR,ON=16;
//
**********************************************
//
**
**
//
**
MASTERFILE : MF.CTY11.Z15075
**
//
**
**
//
**
SUCCESSFULLY PROCESSED
**
//
**
ERFOLGREICH AUSGEFUEHRT
**
//
**
PROCESADO EXITOSO
**
//
**
**
//
**********************************************
<RESET CFOPT;
<ENDFILE;
/*
.ERROR <STEP;
//
**********************************************
//
**
**
//
**
MASTERFILE : MF.CTY11.Z15075
**
//
**
**
//
**
ABORTED
**
//
**
ABGEBROCHEN
**
//
**
ABORTADO
**
//
**
**
//
**********************************************
<SET CFOPT:SCOPE=GLOBAL,ON=16;
<ENDFILE;

36

SN2040E6A01

Patchset Incorporation

3.1.1.3

Siemens

PA-File Example

<CMDFILE;
/*
*/
/***********************************************************************
/**
**
/** PATCH-NAME
: W1189L2Z
04 Y **
/** VERSION
: 0001
Y E **
/** TEST-PART-APS : WOMXBZ1V1150
**
/**
**
/** FML
: I22147
**
/** LKF
:
**
/**
**
/** UNIT
: CP
**
/**
**
/** SOURCE
: Q.PB.PID2PA6S.C.C.1617
**
/**
**
/** TITLE
: Check target LAU state too if
**
/**
CONF LAU UNA->ACT
(V11/SR6)
**
/**
**
/** DEPENDENCIES:
**
/** None.
**
/** INCORPORATION PROCEDURE:
**
/** The patch must be incorporated by EXEC CMDFILE command.
**
/** ERROR DESCRIPTION:
**
/** If the configuration of the LAU UNA -> ACT will not be
**
/** executed by any reason an "EXEC'D" mask will be outputted.
**
/** If one checks the actual state of the LAU it is still UNA.
**
/** TEST DESCRIPTION:
**
/** The error can only be tested by the aid of an appropriate IDS
**
/** patch which turns the IOP:LAU acknowledge into a rejection.
**
/** PATCH DESCRIPTION:
**
/** During an IOP:LAU activation also its LAU has to be configured
**
/** according to the state the LAU had before.
**
/** As the target state UNA is not allowed during configuration
**
/** a LAU having the state UNA
will be configured to ACT.
**
/** If this configuration command fails no action will be started.
**
/**
**
/** If the LAU should be configured UNA -> MBL as the part of the
**
/** maintenance procedure a rejection mask should be output.
**
/**
**
/** In order to distinguish the two actions not only the start
**
/** LAU state but also the target LAU state should be checked.
**
/** OLD SOURCE:
**
/**
**
/** CONFLAULNK_OK: PROC(CONFRSLT
MDL0000_MESSAGE_STRUCT,
**
/**
CONFIGUNIT ZCHUNTP
,
**
/**
PHASE_TYPE CONFIG_PHASE
)
**
/**
RETURNS(BOOL);
**
/** /***************************************************************+ **
/** **
+ **
/** **
**
/** ** PROC-NAME : CONFLAULNK_OK
+ **
/** **
**
/** ** LONG-NAME : CHECK CONF LAU RESULTS
+ **
/** **
**
/** **
**
/** ****************************************************************+ **

SN2040E6A01

37

Siemens

Patchset Incorporation




/*
/* CMDFILE GENERATED BY PATCH113 ON MVS
/* TARGET SYSTEM:
CP
/* ONLINE PATCHTOOL: PAT
/*
<SET CFOPT: DANCMD=EXEC, ACKREQ=POS, ACKCFS=ERROR, OFF=16;
//
************************************************************
//
**
**
//
** COMMANDFILE FOR PATCH APSLMY00.W1189L2Z.0001.0 STARTED **
//
**
**
//
************************************************************
<ENTR CPPRPCH:
#ID="APSLMY00.W1189L2Z.0001.0",
#INSRADDR="BBSCPA0C.PID2PA6C_1617+H'761A"&&"+H'6",
#SUBPPART=1-LAST,
#NEWCNT="9FFC000000040C280003001866184A28001966124A2E0026670CDFFC
#000000044EF9.A(B"&
#"BSCPA0C.PID2PA6C_1617+H'7628)DFFC000000042D48FF184EF9.A(
#BBSCPA0C.PID2PA6"&
#"C_1617+H'7636)",
#OLDCNT="0C2800030018";
<STEP;
<SKIP CMD: LABEL=ERROR0, ON=32;
/*
<ENTR CPPRPCH:
#ID="APSLMY00.W1189L2Z.0001.0",
#SUBPCHNO=1;
<STEP;
<SKIP CMD: LABEL=ERROR, ON=32;
/*
<UPD CPPRPCH: ID="APSLMY00.W1189L2Z.0001.0";
<STEP;
<SKIP CMD: LABEL=ERRORC, ON=32;
/*
<INCR APSVN;
<RESET CFOPT;
<ENDFILE;
/*
.ERROR0 <STEP;
//
***********************************************************
//
**
**
//
** PATCH-ID APSLMY00.W1189L2Z.0001.0 ALREADY EXISTING OR **
//
** ERROR DURING FIRST ENTR-CPPRPCH (SEE DISPLAY OUTPUT) **
//
**
**
//
***********************************************************
<SET CFOPT: ACKCFS=ALL;
<DISP CPPRPCH: ID="APSLMY00.W1189L2Z.0001.0";
<STEP;
<SET CFOPT: ACKCFS=ERROR, SCOPE=GLOBAL, ON=16;
<ENDFILE;
/*
.ERROR <STEP;
<SET CFOPT: ACKCFS=ALL;
<DISP CPPRPCH: ID="APSLMY00.W1189L2Z.0001.0";
<STEP;
<SET CFOPT: ACKCFS=ERROR;
/*

38

SN2040E6A01

Patchset Incorporation

Siemens

.ERRORC <STEP;
//
**********************************************************
//
**
**
//
** ERROR DURING ENTR-,ACT- OR UPD- CPPRPCH
**
//
** PATCH-ID APSLMY00.W1189L2Z.0001.0 WILL BE REMOVED
**
//
**
**
//
**********************************************************
<CAN CPPRPCH: ID="APSLMY00.W1189L2Z.0001.0";
<STEP;
<SKIP CMD: LABEL=ERRORA, ON=32;
/*
<SET CFOPT: SCOPE=GLOBAL, ON=16;
//
**********************************************************
//
**
**
//
** COMMANDFILE ABORTED
**
//
** PATCH-ID APSLMY00.W1189L2Z.0001.0
**
//
**
**
//
**********************************************************
<ENDFILE;
.ERRORA <STEP;
//
**********************************************************
//
**
**
//
** ERROR DURING CANCEL CPPRPCH
**
//
** PATCH-ID APSLMY00.W1189L2Z.0001.0
**
//
**
**
//
**********************************************************
<SET CFOPT: ACKCFS=ALL;
<DISP CPPRPCH: ID="APSLMY00.W1189L2Z.0001.0";
<STEP;
<SET CFOPT: ACKCFS=ERROR, SCOPE=GLOBAL, ON=16;
//
**********************************************************
//
**
**
//
** COMMANDFILE ABORTED
**
//
** PATCH-ID APSLMY00.W1189L2Z.0001.0
**
//
**
**
//
**********************************************************
<ENDFILE;

SN2040E6A01

39

Patchset Incorporation

Siemens

3.1.2 Example: CMD-File Interruption due to an Already


Existing Patch (from AutoPatch Light)
3.1.2.1

MLOG

SETCFOPT:ON=2;
END JOB 0553

EXEC'D

EXECCMDFILE
0558
FILE=
073CTY11.PM;
EXECCMDFILE:FILE=073CTY11.PM;
END TEXT JOB 0558

STARTED

SKIPCMD:LABEL=MASTER,ON=2;
END TEXT JOB 0566

STARTED

X677/CTYCPZ1V1150/P69/013
0567(0558)
OMT-00/EWSD0

99-08-02

SETCFOPT:ACKCFS=ERROR,OFF=16,DANCMD=EXEC,ACKREQ=POS;
END JOB 0567
X677/CTYCPZ1V1150/P69/013
0558
OMT-00/EWSD0

14:32:58

2977/00007
EXEC'D

99-08-02

14:33:00

2980/00000

COMMANDFILE PROCESSING
//
********************************************************
//
** PATCHSET RELEASED AT: 1999.05.04 12:27
**
//
**
**
//
**
STARTED
**
//
** PRIMARY MASTERFILE : PM.CTY11.K50.P073 GESTARTET **
//
**
ARRANCADO **
//
**
**
//
********************************************************
END TEXT JOB 0558
X677/CTYCPZ1V1150/P70/013
0558
OMT-00/EWSD0

99-08-02

COMMANDFILE PROCESSING CONTINUATION


// *******************************************************
// **
**
// ** PRIMARY MASTERFILE : PM.CTY11.K50.P073
**
// **
ABORTED
**
// **
ABGEBROCHEN
**
// **
ABORTADO
**
// **
**
// *******************************************************
END TEXT JOB 0558
EXECCMDFILE:FILE=073CTY11.PM;
END JOB 0558

40

14:33:41

2980/00000

FINISHED

SN2040E6A01

Patchset Incorporation

3.1.2.2

Siemens

PT. Symptom File

DISPFILE:FILE=PT.;
USED SPACE :

EXEC'D
100 PAGES FOR

1 FILES

FILE
GEN
SIZE
VSN000
VSN001
CLASS TYPE
-----------------+--------+-------+-------------+-------------+----+---PT.CTY11.K50.P073
100
X
TEMP SAM
END JOB 0688
DISPFILETEXT
0691
FILE=
PT.CTY11.K50.P073;
X677/CTYCPZ1V1150/P70/013
0691
OMT-00/EWSD0

99-08-02

14:34:11

2970/06247

NOTES: - UNPRINTABLE CHARACTERS ARE SUBSTITUTED BY '.'


- CONTINUATION LINES OF A RECORD START WITH '>>'
----+----1----+----2----+----3----+----4----+----5----+----6----+----7-X677/CTYCPZ1V1150/P69/013
99-08-02 14:32:59
0569
OMT-00/EWSD0
2978/00006
SKIPCMD:LABEL=CRERROR,ON=32;
END TEXT JOB 0569

STARTED

SKIPCMD:LABEL=EXECUTE;
END TEXT JOB 0570

STARTED

SETCFOPT:OFF=2&16;
END JOB 0571

EXEC'D

COMMANDFILE PROCESSING
//
********************************************************
//
** PATCHSET RELEASED AT: 1999.05.04 12:27
**
//
**
**
//
**
STARTED
**
//
** PRIMARY MASTERFILE : PM.CTY11.K50.P073 GESTARTET **
//
**
ARRANCADO **
//
**
**
//
********************************************************
END TEXT JOB 0558

X677/CTYCPZ1V1150/P69/013
0572
OMT-00/EWSD0
EXECCMDFILE:FILE=MF.CTY11.Z15075;
END TEXT JOB 0572

SN2040E6A01

99-08-02

14:33:01

2978/00006
STARTED

41

Patchset Incorporation

Siemens

SETCFOPT:ACKCFS=ERROR,OFF=16,DANCMD=EXEC,ACKREQ=POS;
END JOB 0573
X677/CTYCPZ1V1150/P69/013
0572
OMT-00/EWSD0

EXEC'D

99-08-02

14:33:01

2980/00000

COMMANDFILE PROCESSING CONTINUATION


//
**********************************************
//
** PATCHSET RELEASED AT: 1999.05.04 12:27
**
//
**
**
//
**
STARTED
**
//
** MASTERFILE : MF.CTY11.Z15075 GESTARTET **
//
**
ARRANCADO **
//
** LOADTYPE
:
**
//
**
**
//
**********************************************
END TEXT JOB 0572

EXECCMDFILE:FILE=PA.W1189L2Z.V0001,STEP;
END TEXT JOB 0574

STARTED

SETCFOPT:ACKCFS=ERROR,OFF=16,DANCMD=EXEC,ACKREQ=POS;
END JOB 0575

X677/CTYCPZ1V1150/P69/013
0574
OMT-00/EWSD0

EXEC'D

99-08-02

14:33:02

2980/00000

COMMANDFILE PROCESSING CONTINUATION


//
************************************************************
//
**
**
//
** COMMANDFILE FOR PATCH APSLMY00.W1189L2Z.0001.0 STARTED **
//
**
**
//
************************************************************
END TEXT JOB 0574

X677/CTYCPZ1V1150/P69/013
0576
OMT-00/EWSD0

99-08-02

ENTRCPPRPCH:ID="APSLMY00.W1189L2Z.0001.0",INSRADDR=
"BBSCPA0C.PID2PA6C_1617+H'761A"&&"+H'6",SUBPPART=1-LAST,
NEWCNT=
"9FFC000000040C280003001866184A28001966124A2E0026670CDFFC000
000044EF9.A(B"&
"BSCPA0C.PID2PA6C_1617+H'7628)DFFC000000042D48FF184EF9.A(BBS
CPA0C.PID2PA6"&"C_1617+H'7636)",OLDCNT="0C2800030018";
END TEXT JOB 0576

X677/CTYCPZ1V1150/P69/013
0576
OMT-00/EWSD0

14:33:09

3087/06971

99-08-02

EXEC'D

14:33:09

3087/07695

ENTRCPPRPCH:ID="APSLMY00.W1189L2Z.0001.0",INSRADDR=
"BBSCPA0C.PID2PA6C_1617+H'761A"&&"+H'6",SUBPPART=1-LAST,
NEWCNT=
"9FFC000000040C280003001866184A28001966124A2E0026670CDFFC000

42

SN2040E6A01

Patchset Incorporation

Siemens

000044EF9.A(B"&
"BSCPA0C.PID2PA6C_1617+H'7628)DFFC000000042D48FF184EF9.A(BBS
CPA0C.PID2PA6"&"C_1617+H'7636)",OLDCNT="0C2800030018";
END TEXT JOB 0576
X677/CTYCPZ1V1150/P69/013
99-08-02
0576
OMT-00/EWSD0
3087/06977
ENTRCPPRPCH:ID="APSLMY00.W1189L2Z.0001.0",INSRADDR=
"BBSCPA0C.PID2PA6C_1617+H'761A"&&"+H'6",SUBPPART=1-LAST,
NEWCNT=
"9FFC000000040C280003001866184A28001966124A2E0026670CDFFC000
000044EF9.A(B"&
"BSCPA0C.PID2PA6C_1617+H'7628)DFFC000000042D48FF184EF9.A(BBS
CPA0C.PID2PA6"&"C_1617+H'7636)",OLDCNT="0C2800030018";
END JOB 0576

SKIPCMD:LABEL=ERROR0,ON=32;
END TEXT JOB 0594

X677/CTYCPZ1V1150/P69/013
0595
OMT-00/EWSD0

99-08-02

99-08-02

EXEC'D

99-08-02

14:33:16

3087/06977
EXEC'D

STARTED

99-08-02

14:33:22

3087/06971

UPDCPPRPCH:ID="APSLMY00.W1189L2Z.0001.0";
END TEXT JOB 0612

EXEC'D

99-08-02

14:33:24

3087/06971

UPDCPPRPCH:ID="APSLMY00.W1189L2Z.0001.0";
END TEXT JOB 0612

SN2040E6A01

14:33:16

3087/07695

SKIPCMD:LABEL=ERROR,ON=32;
END TEXT JOB 0611

X677/CTYCPZ1V1150/P69/013
0612
OMT-00/EWSD0

14:33:16

EXEC'D

ENTRCPPRPCH:ID="APSLMY00.W1189L2Z.0001.0",SUBPCHNO=1;
END JOB 0595

X677/CTYCPZ1V1150/P69/013
0612
OMT-00/EWSD0

EXEC'D

3087/06971

ENTRCPPRPCH:ID="APSLMY00.W1189L2Z.0001.0",SUBPCHNO=1;
END TEXT JOB 0595

X677/CTYCPZ1V1150/P69/013
0595
OMT-00/EWSD0

14:33:10

STARTED

ENTRCPPRPCH:ID="APSLMY00.W1189L2Z.0001.0",SUBPCHNO=1;
END TEXT JOB 0595

X677/CTYCPZ1V1150/P69/013
0595
OMT-00/EWSD0

EXEC'D

EXEC'D

43

Patchset Incorporation

Siemens

UPDCPPRPCH:ID="APSLMY00.W1189L2Z.0001.0";
END TEXT JOB 0612
X677/CTYCPZ1V1150/P69/013
0612
OMT-00/EWSD0
3087/06977

EXEC'D
99-08-02

14:33:24

UPDCPPRPCH:ID="APSLMY00.W1189L2Z.0001.0";
END JOB 0612

EXEC'D

SKIPCMD:LABEL=ERRORC,ON=32;
END TEXT JOB 0629

X677/CTYCPZ1V1150/P70/013
0630
OMT-00/EWSD0

STARTED

99-08-02

14:33:24

2988/00007

INCRAPSVN;
END JOB 0630

EXEC'D

RESETCFOPT;
END JOB 0631

EXEC'D

X677/CTYCPZ1V1150/P70/013
0574
OMT-00/EWSD0

99-08-02

14:33:25

2977/01274

EXECCMDFILE:FILE=PA.W1189L2Z.V0001,STEP;
END TEXT JOB 0574

FINISHED

SKIPCMD:LABEL=ERROR,ON=32;
END TEXT JOB 0632

STARTED

SKIPCMD:LABEL=ERROR,ON=16;
END TEXT JOB 0633

STARTED

X677/CTYCPZ1V1150/P70/013
0634
OMT-00/EWSD0

99-08-02

14:33:25

2978/00006

EXECCMDFILE:FILE=PA.W6377L2Z.V0002,STEP;
END TEXT JOB 0634
X677/CTYCPZ1V1150/P70/013
0635
OMT-00/EWSD0

STARTED

99-08-02

14:33:25

2977/00007

SETCFOPT:ACKCFS=ERROR,OFF=16,DANCMD=EXEC,ACKREQ=POS;
END JOB 0635

X677/CTYCPZ1V1150/P70/013
0634
OMT-00/EWSD0

EXEC'D

99-08-02

14:33:26

2980/00000

COMMANDFILE PROCESSING CONTINUATION


//
************************************************************
//
**
**
//
** COMMANDFILE FOR PATCH APSLMY00.W6377L2Z.0002.0 STARTED **
//
**
**
//
************************************************************
END TEXT JOB 0634

44

SN2040E6A01

Patchset Incorporation

Siemens

ENTRCPPRPCH:ID="APSLMY00.W6377L2Z.0002.0",INSRADDR=
"BBSCPA0C.TSPROA0C_4001+H'42C"&&"+H'6",SUBPPART=1-LAST,
NEWCNT=
"4A2EFC686716204E508843EEFC6CB189660AB18966064EF9.A(BBSCPA0C
.TSPROA0C_400"&
"1+H'43C)4EF9.A(BBSCPA0C.TSPROA0C_4001+H'442)",OLDCNT=
"204E508843EE";
DISPLAY/ERROR MESSAGE NUMBER:
LAST DISP/ERROR MESSAGE FOR TASK:

1
YES

PATCH TOOL EXECUTION ERROR


FAILING TRANSACTION:
AFFECTED PLATFORM:
AFFECTED CAPSULE:
AFFECTED PATCH:
ERROR NUMBER:
ERROR REASON:
ERROR DETECTED BY:

APSLMY00
W6377L2Z.0002.0
2007
PATCH STATE AND COMMAND NOT MATCHING
PAT FRONTEND: SEMANTICS CHECKER

SUPPLEMENTARY INFORMATION

LIST OF PLATFORMS NOT RESPONDING


TYPE-NUMBER-SIDE TYPE-NUMBER-SIDE TYPE-NUMBER-SIDE
---------------- ---------------- ---------------NO (MORE) DATA FOR DISPLAY AVAILABLE

TYPE-NUMBER-SIDE
----------------

END TEXT JOB 0636

X677/CTYCPZ1V1150/P70/013
0636
OMT-00/EWSD0

99-08-02

14:33:31

3090/06978

ENTRCPPRPCH:ID="APSLMY00.W6377L2Z.0002.0",INSRADDR=
"BBSCPA0C.TSPROA0C_4001+H'42C"&&"+H'6",SUBPPART=1-LAST,
NEWCNT=
"4A2EFC686716204E508843EEFC6CB189660AB18966064EF9.A(BBSCPA0C
.TSPROA0C_400"&
"1+H'43C)4EF9.A(BBSCPA0C.TSPROA0C_4001+H'442)",OLDCNT=
"204E508843EE";

NOT EXEC'D

PATCH JOB FINISHED


END JOB 0636

X677/CTYCPZ1V1150/P70/013
0651
OMT-00/EWSD0
SKIPCMD:LABEL=ERROR0,ON=32;
END TEXT JOB 0651

SN2040E6A01

99-08-02

14:33:31

2978/00006
STARTED

45

Patchset Incorporation

Siemens

COMMANDFILE PROCESSING CONTINUATION


//
***********************************************************
//
**
**
//
** PATCH-ID APSLMY00.W6377L2Z.0002.0 ALREADY EXISTING OR **
//
** ERROR DURING FIRST ENTR-CPPRPCH (SEE DISPLAY OUTPUT) **
//
**
**
//
***********************************************************
END TEXT JOB 0634

SETCFOPT:ACKCFS=ALL;
END JOB 0652

X677/CTYCPZ1V1150/P70/013
0653
OMT-00/EWSD0

EXEC'D

99-08-02

14:33:37

3091/06971

DISPCPPRPCH:ID="APSLMY00.W6377L2Z.0002.0";
PATCH TOOL TRANSACTION DM (DISPLAY MEMORY)
END TEXT JOB 0653

X677/CTYCPZ1V1150/P70/013
0653
OMT-00/EWSD0

EXECUTED

99-08-02

14:33:39

3091/06971

DISPCPPRPCH:ID="APSLMY00.W6377L2Z.0002.0";
PATCH TOOL TRANSACTION DD (DISPLAY DISK)
END TEXT JOB 0653

X677/CTYCPZ1V1150/P70/013
0653
OMT-00/EWSD0

EXECUTED

99-08-02

14:33:39

3091/07696

DISPCPPRPCH:ID="APSLMY00.W6377L2Z.0002.0";
DISPLAY/ERROR MESSAGE NUMBER:
1
LAST DISP/ERROR MESSAGE FOR TASK: NO
PATCH DATA
PATCH IDENTIFIER:
TOTAL SUBPATCH NUMBER:
PATCH STATUS:
DATE/TIME OF LAST MODIFICATION
ON DISK (PRPCH)/IN MEM. (TRPCH):

APSLMY00.W6377L2Z.0002.0
1
UPD
99-08-02/14:30:59

SUBPATCH DATA

46

SUBPATCH NUMBER:
SUBPATCH TYPE:
BEGIN ADDRESS/REFERENCE NO:
PATCH DISTANCE/VARIABLE LENGTH:
LAST SUBPATCH PART NUMBER:
SUBPATCH CLOSED:

1
INSRUC
BBSCPA0C.TSPROA0C+H'0000042C
H'00000006
1
YES

RUCKSACK CONTENT FOLLOWS:

NO

SN2040E6A01

Patchset Incorporation

Siemens

SUBPATCH CONTENT TABLE


OFFSET FROM
CONTENT
CAPSULE BEGIN
(IF NO RUCKSACK, EACH 2ND LINE = OLDCNT)
----------------+------------------------------------------------------H'4606CE70
H'60FFF2DB 870A
H'4606CE70
H'204E5088 43EE
END TEXT JOB 0653

X677/CTYCPZ1V1150/P70/013
0653
OMT-00/EWSD0

99-08-02

14:33:39

3091/07696

DISPCPPRPCH:ID="APSLMY00.W6377L2Z.0002.0";
DISPLAY/ERROR MESSAGE NUMBER:
2
LAST DISP/ERROR MESSAGE FOR TASK: NO
PATCH DATA
PATCH IDENTIFIER:
TOTAL SUBPATCH NUMBER:
PATCH STATUS:
DATE/TIME OF LAST MODIFICATION
ON DISK (PRPCH)/IN MEM. (TRPCH):

APSLMY00.W6377L2Z.0002.0
1
UPD
99-08-02/14:30:59

SUBPATCH DATA
SUBPATCH NUMBER:
SUBPATCH TYPE:
BEGIN ADDRESS/REFERENCE NO:
PATCH DISTANCE/VARIABLE LENGTH:
LAST SUBPATCH PART NUMBER:
SUBPATCH CLOSED:

1
INSRUC
APSLMY00+H'4606CE70
H'00000006
1
YES

RUCKSACK CONTENT FOLLOWS:

YES

SUBPATCH CONTENT TABLE


OFFSET FROM
CONTENT
CAPSULE BEGIN
(IF NO RUCKSACK, EACH 2ND LINE = OLDCNT)
----------------+------------------------------------------------------H'38E2557C
H'4A2EFC68 6716204E 508843EE FC6CB189 660AB189 66064EF9
H'38E25594
H'4606CE80 4EF94606 CE8660FF 0D2478D6
END TEXT JOB 0653

X677/CTYCPZ1V1150/P70/013
0653
OMT-00/EWSD0

99-08-02

14:33:39

3091/06977

DISPCPPRPCH:ID="APSLMY00.W6377L2Z.0002.0";

EXEC'D

PATCH JOB FINISHED


END JOB 0653
SETCFOPT:ACKCFS=ERROR,ON=16,SCOPE=GLOBAL;
END JOB 0672

SN2040E6A01

EXEC'D

47

Patchset Incorporation

Siemens

EXECCMDFILE:FILE=PA.W6377L2Z.V0002,STEP;
END TEXT JOB 0634

FINISHED

SKIPCMD:LABEL=ERROR,ON=32;
END TEXT JOB 0673

STARTED

SKIPCMD:LABEL=ERROR,ON=16;
END TEXT JOB 0674

STARTED

X677/CTYCPZ1V1150/P70/013
0572
OMT-00/EWSD0

99-08-02

14:33:40

2980/00000

COMMANDFILE PROCESSING CONTINUATION


//
**********************************************
//
**
**
//
**
MASTERFILE : MF.CTY11.Z15075
**
//
**
**
//
**
ABORTED
**
//
**
ABGEBROCHEN
**
//
**
ABORTADO
**
//
**
**
//
**********************************************
END TEXT JOB 0572

SETCFOPT:ON=16,SCOPE=GLOBAL;
END JOB 0676

X677/CTYCPZ1V1150/P70/013
0572
OMT-00/EWSD0

EXEC'D

99-08-02

EXECCMDFILE:FILE=MF.CTY11.Z15075;
END TEXT JOB 0572

X677/CTYCPZ1V1150/P70/013
0677
OMT-00/EWSD0

FINISHED

99-08-02

STARTED

99-08-02

STARTED

SETCFOPT:OFF=2&16,SCOPE=GLOBAL;
END JOB 0679

48

14:33:41

2978/00006

SKIPCMD:LABEL=MFERR1,ON=16;
END TEXT JOB 0678

X677/CTYCPZ1V1150/P70/013
0558
OMT-00/EWSD0

14:33:40

2978/00006

SKIPCMD:LABEL=MFERR1,ON=32;
END TEXT JOB 0677
X677/CTYCPZ1V1150/P70/013
0678
OMT-00/EWSD0

14:33:40

2977/01274

EXEC'D

99-08-02

14:33:41

2980/00000

SN2040E6A01

Patchset Incorporation

Siemens

COMMANDFILE PROCESSING CONTINUATION


// *******************************************************
// **
**
// ** PRIMARY MASTERFILE : PM.CTY11.K50.P073
**
// **
ABORTED
**
// **
ABGEBROCHEN
**
// **
ABORTADO
**
// **
**
// *******************************************************
END TEXT JOB 0558
X677/CTYCPZ1V1150/P70/013
0680
OMT-00/EWSD0

99-08-02

RESETCFOPT;
END JOB 0680
X677/CTYCPZ1V1150/P70/013
0681
OMT-00/EWSD0
DECOUTDIV;
END JOB 0681

14:33:42

2977/00007
EXEC'D

99-08-02

14:33:42

2966/00007
EXEC'D

END JOB 0691 EXEC'D

SN2040E6A01

49

Patchset Incorporation

Siemens

3.1.3 Example: CMD-File Interruption due to an Already


Existing Patch (from AutoPatch for NodeCommander)
3.1.3.1

Task Manager Protocol

Task Manager (ASWTASK) V302.01

Reportlist Printout

***** Patch Action (ASWINC) V302.01


***** Copyright (c) SIEMENS AG 1998
----------------------------------------------------------------------Installation name : ICN VZ TI
Function
: NE Action: x677
Start Function
: 99.08.02 - 14:34:06
AICOM: + user - patch / NE - x677(ctycpz1v1150)
AICOM: + Authentication!
AICOM: + Session established!
AICOM: DISP MD;
AICOM: + Command accepted!
AICOM: + F1 Label: 300
AICOM: + F1 Label: check ok
***** Patch Action (ASWINC) V302.01
***** Copyright (c) SIEMENS AG 1998
----------------------------------------------------------------------Installation name : ICN VZ TI
Function
: NE Action: x677
Start Function
: 99.08.02 - 14:35:13
AICOM: + Transfer and start command file!
AICOM: + user - patch / NE - x677(ctycpz1v1150)
AICOM: + Authentication!
AICOM: + Session established!
AICOM: DISPGEN;
AICOM: + Command accepted!
AICOM:
TRANSFILE:FILE=073x677.pm,PRONAM=/"EMNOS1",USINF="akusw",MODE=OVWR,COPMOD=C
HAR;
AICOM: + Command accepted!
AICOM: + NE job number: 1351
AICOM: DISPTIME;
AICOM: + Command accepted!
AICOM: + NE date - 99-08-02 / NE time - 15:01:37
AICOM: + NE APS - CTYCPZ1V1150/P70/013
AICOM: EXECCMDFILE:FILE=073x677.pm;
AICOM: + Command accepted!
AICOM: + NE job number: 1361
AICOM: + No event!
***** Patch Action (ASWINC) V302.01
***** Copyright (c) SIEMENS AG 1998

50

SN2040E6A01

Patchset Incorporation

Siemens

----------------------------------------------------------------------Installation name : ICN VZ TI


Function
: NE Action: x677
Start Function
: 99.08.02 - 14:37:32
AICOM: + user - patch / NE - x677(ctycpz1v1150)
AICOM: + Authentication!
AICOM: + Session established!
AICOM: DISPJOB:JN=1361;
AICOM: + Command accepted!
AICOM: + Last job check: 15:03:42
AICOM: + NE job: running
NE HANDLER: ! Patch error - master file: : 1
NE HANDLER: ! PATCH ERROR!
End
Function
: 99.08.02 - 14:42:49

SN2040E6A01

51

Patchset Incorporation

Siemens

3.1.3.2

PT. Symptom File

DISPFILE:FILE=PT.;

USED SPACE :

EXEC'D

100 PAGES FOR

1 FILES

FILE
GEN
SIZE
VSN000
VSN001
CLASS TYPE
-----------------+--------+-------+-------------+-------------+----+---PT.AP.13
100
X
TEMP SAM
END JOB 2649
DISPFILETEXT
2656
FILE=
PT.AP.13;

X677/CTYCPZ1V1150/P71/013
2656
OMT-00/EWSD0

99-08-02

15:44:25

2970/06247

NOTES: - UNPRINTABLE CHARACTERS ARE SUBSTITUTED BY '.'


- CONTINUATION LINES OF A RECORD START WITH '>>'
----+----1----+----2----+----3----+----4----+----5----+----6----+----7-X677/CTYCPZ1V1150/P70/013
99-08-02 15:06:56
1656
csfs2/PATCH
2978/00006
SKIPCMD:LABEL=CRERROR,ON=32;
END TEXT JOB 1656

STARTED

SKIPCMD:LABEL=EXECUTE;
END TEXT JOB 1657

STARTED

SETCFOPT:OFF=2&16;
END JOB 1658
X677/CTYCPZ1V1150/P70/013
1659
csfs2/PATCH
DELFILE:FILE=PT.AP.;
END TEXT JOB 1659

X677/CTYCPZ1V1150/P70/013
1659
csfs2/PATCH
DELFILE:FILE=PT.AP.;

EXEC'D

99-08-02

15:06:56

2967/01767
ACCEPTED

99-08-02

15:06:56

2969/01766
NOT EXEC'D

FILE
ERROR INFORMATION
-----------------------------------------------------------------------PT.AP.13
FILE IN USE
END JOB 1659

52

SN2040E6A01

Patchset Incorporation

Siemens

COMMANDFILE PROCESSING CONTINUATION


//
********************************************************
//
** PATCHSET RELEASED AT: 1999.05.04 12:27
**
//
**
**
//
**
STARTED
**
//
** PRIMARY MASTERFILE : PM.CTY11.K50.P073 GESTARTET **
//
**
ARRANCADO **
//
**
**
//
********************************************************
END TEXT JOB 1361

X677/CTYCPZ1V1150/P70/013
1660
csfs2/PATCH

99-08-02

EXECCMDFILE:FILE=MF.CTY11.Z15075;
END TEXT JOB 1660

X677/CTYCPZ1V1150/P70/013
1661
csfs2/PATCH

STARTED

99-08-02

15:06:57

2977/00007

SETCFOPT:ACKCFS=ERROR,OFF=16,DANCMD=EXEC,ACKREQ=POS;
END JOB 1661

X677/CTYCPZ1V1150/P70/013
1660
csfs2/PATCH

15:06:57

2978/00006

EXEC'D

99-08-02

15:06:58

99-08-02

15:06:58

2980/00000

COMMANDFILE PROCESSING CONTINUATION


//
**********************************************
//
** PATCHSET RELEASED AT: 1999.05.04 12:27
**
//
**
**
//
**
STARTED
**
//
** MASTERFILE : MF.CTY11.Z15075 GESTARTET **
//
**
ARRANCADO **
//
** LOADTYPE
:
**
//
**
**
//
**********************************************
END TEXT JOB 1660
X677/CTYCPZ1V1150/P70/013
1662
csfs2/PATCH

2978/00006

EXECCMDFILE:FILE=PA.W1189L2Z.V0001,STEP;
END TEXT JOB 1662

STARTED

SETCFOPT:ACKCFS=ERROR,OFF=16,DANCMD=EXEC,ACKREQ=POS;

EXEC'D

END JOB 1663


X677/CTYCPZ1V1150/P70/013
1662
csfs2/PATCH

SN2040E6A01

99-08-02

15:06:58

2980/00000

53

Patchset Incorporation

Siemens

COMMANDFILE PROCESSING CONTINUATION


//
************************************************************
//
**
**
//
** COMMANDFILE FOR PATCH APSLMY00.W1189L2Z.0001.0 STARTED **
//
**
**
//
************************************************************
END TEXT JOB 1662



COMMANDFILE PROCESSING CONTINUATION
//
************************************************************
//
**
**
//
** COMMANDFILE FOR PATCH APSLMY00.W6377L2Z.0002.0 STARTED **
//
**
**
//
************************************************************
END TEXT JOB 1722

X677/CTYCPZ1V1150/P71/013
1724
csfs2/PATCH

99-08-02

15:07:27

3090/07692

ENTRCPPRPCH:ID="APSLMY00.W6377L2Z.0002.0",INSRADDR=
"BBSCPA0C.TSPROA0C_4001+H'42C"&&"+H'6",SUBPPART=1-LAST,
NEWCNT=
"4A2EFC686716204E508843EEFC6CB189660AB18966064EF9.A(BBSCPA0C
.TSPROA0C_400"&
"1+H'43C)4EF9.A(BBSCPA0C.TSPROA0C_4001+H'442)",OLDCNT=
"204E508843EE";
DISPLAY/ERROR MESSAGE NUMBER:
LAST DISP/ERROR MESSAGE FOR TASK:

1
YES

PATCH TOOL EXECUTION ERROR


FAILING TRANSACTION:
AFFECTED PLATFORM:
AFFECTED CAPSULE:
AFFECTED PATCH:
ERROR NUMBER:
ERROR REASON:
ERROR DETECTED BY:

APSLMY00
W6377L2Z.0002.0
2007
PATCH STATE AND COMMAND NOT MATCHING
PAT FRONTEND: SEMANTICS CHECKER

SUPPLEMENTARY INFORMATION
LIST OF PLATFORMS NOT RESPONDING
TYPE-NUMBER-SIDE TYPE-NUMBER-SIDE TYPE-NUMBER-SIDE
---------------- ---------------- ---------------NO (MORE) DATA FOR DISPLAY AVAILABLE
END TEXT JOB 1724

X677/CTYCPZ1V1150/P71/013
1724
csfs2/PATCH

54

TYPE-NUMBER-SIDE
----------------

99-08-02

15:07:27

3090/06978

SN2040E6A01

Patchset Incorporation

Siemens

ENTRCPPRPCH:ID="APSLMY00.W6377L2Z.0002.0",INSRADDR=
"BBSCPA0C.TSPROA0C_4001+H'42C"&&"+H'6",SUBPPART=1-LAST,
NEWCNT=
"4A2EFC686716204E508843EEFC6CB189660AB18966064EF9.A(BBSCPA0C
.TSPROA0C_400"&
"1+H'43C)4EF9.A(BBSCPA0C.TSPROA0C_4001+H'442)",OLDCNT=
"204E508843EE";

NOT EXEC'D

PATCH JOB FINISHED


END JOB 1724

X677/CTYCPZ1V1150/P71/013
1738
csfs2/PATCH

99-08-02

SKIPCMD:LABEL=ERROR0,ON=32;
END TEXT JOB 1738

X677/CTYCPZ1V1150/P71/013
1722
csfs2/PATCH

15:07:28

2978/00006
STARTED

99-08-02

15:07:28

2980/00000

COMMANDFILE PROCESSING CONTINUATION


//
***********************************************************
//
**
**
//
** PATCH-ID APSLMY00.W6377L2Z.0002.0 ALREADY EXISTING OR **
//
** ERROR DURING FIRST ENTR-CPPRPCH (SEE DISPLAY OUTPUT) **
//
**
**
//
***********************************************************
END TEXT JOB 1722

X677/CTYCPZ1V1150/P71/013
1739
csfs2/PATCH

99-08-02

SETCFOPT:ACKCFS=ALL;
END JOB 1739

X677/CTYCPZ1V1150/P71/013
1740
csfs2/PATCH

15:07:28

2977/00007
EXEC'D

99-08-02

15:07:34

3091/06971

DISPCPPRPCH:ID="APSLMY00.W6377L2Z.0002.0";
PATCH TOOL TRANSACTION DM (DISPLAY MEMORY)
END TEXT JOB 1740

X677/CTYCPZ1V1150/P71/013
1740
csfs2/PATCH

EXECUTED

99-08-02

15:07:35

3091/06971

DISPCPPRPCH:ID="APSLMY00.W6377L2Z.0002.0";
PATCH TOOL TRANSACTION DD (DISPLAY DISK)
END TEXT JOB 1740

SN2040E6A01

EXECUTED

55

Patchset Incorporation

Siemens

DISPCPPRPCH:ID="APSLMY00.W6377L2Z.0002.0";
DISPLAY/ERROR MESSAGE NUMBER:
1
LAST DISP/ERROR MESSAGE FOR TASK: NO
PATCH DATA
PATCH IDENTIFIER:
TOTAL SUBPATCH NUMBER:
PATCH STATUS:
DATE/TIME OF LAST MODIFICATION
ON DISK (PRPCH)/IN MEM. (TRPCH):

APSLMY00.W6377L2Z.0002.0
1
UPD
99-08-02/14:30:59

SUBPATCH DATA
SUBPATCH NUMBER:
SUBPATCH TYPE:
BEGIN ADDRESS/REFERENCE NO:
PATCH DISTANCE/VARIABLE LENGTH:
LAST SUBPATCH PART NUMBER:
SUBPATCH CLOSED:

1
INSRUC
BBSCPA0C.TSPROA0C+H'0000042C
H'00000006
1
YES

RUCKSACK CONTENT FOLLOWS:

NO

SUBPATCH CONTENT TABLE


OFFSET FROM
CONTENT
CAPSULE BEGIN
(IF NO RUCKSACK, EACH 2ND LINE = OLDCNT)
----------------+------------------------------------------------------H'4606CE70
H'60FFF2DB 870A
H'4606CE70
H'204E5088 43EE
END TEXT JOB 1740

X677/CTYCPZ1V1150/P71/013
1740
csfs2/PATCH

99-08-02

15:07:35

3091/07696

DISPCPPRPCH:ID="APSLMY00.W6377L2Z.0002.0";
DISPLAY/ERROR MESSAGE NUMBER:
2
LAST DISP/ERROR MESSAGE FOR TASK: NO
PATCH DATA
PATCH IDENTIFIER:
TOTAL SUBPATCH NUMBER:
PATCH STATUS:
DATE/TIME OF LAST MODIFICATION
ON DISK (PRPCH)/IN MEM. (TRPCH):
SUBPATCH DATA
SUBPATCH NUMBER:
SUBPATCH TYPE:
BEGIN ADDRESS/REFERENCE NO:
PATCH DISTANCE/VARIABLE LENGTH:
LAST SUBPATCH PART NUMBER:
SUBPATCH CLOSED:

56

APSLMY00.W6377L2Z.0002.0
1
UPD
99-08-02/14:30:59

1
INSRUC
APSLMY00+H'4606CE70
H'00000006
1
YES

SN2040E6A01

Patchset Incorporation

RUCKSACK CONTENT FOLLOWS:

Siemens

YES

SUBPATCH CONTENT TABLE


OFFSET FROM
CONTENT
CAPSULE BEGIN
(IF NO RUCKSACK, EACH 2ND LINE = OLDCNT)
----------------+------------------------------------------------------H'38E2557C
H'4A2EFC68 6716204E 508843EE FC6CB189 660AB189 66064EF9
H'38E25594
H'4606CE80 4EF94606 CE8660FF 0D2478D6
END TEXT JOB 1740

X677/CTYCPZ1V1150/P71/013
1740
csfs2/PATCH

99-08-02

15:07:36

3091/06977

DISPCPPRPCH:ID="APSLMY00.W6377L2Z.0002.0";

EXEC'D

PATCH JOB FINISHED


END JOB 1740

X677/CTYCPZ1V1150/P71/013
1758
csfs2/PATCH

99-08-02

SETCFOPT:ACKCFS=ERROR,ON=16,SCOPE=GLOBAL;
END JOB 1758

X677/CTYCPZ1V1150/P71/013
1722
csfs2/PATCH

15:07:36

2977/00007
EXEC'D

99-08-02

15:07:36

2977/01274

EXECCMDFILE:FILE=PA.W6377L2Z.V0002,STEP;

FINISHED

END TEXT JOB 1722


X677/CTYCPZ1V1150/P71/013
1759
csfs2/PATCH

99-08-02

SKIPCMD:LABEL=ERROR,ON=32;
END TEXT JOB 1759

X677/CTYCPZ1V1150/P71/013
1760
csfs2/PATCH
SKIPCMD:LABEL=ERROR,ON=16;
END TEXT JOB 1760

SN2040E6A01

15:07:36

2978/00006
STARTED

99-08-02

15:07:36

2978/00006
STARTED

57

Patchset Incorporation

Siemens

X677/CTYCPZ1V1150/P71/013
1660
csfs2/PATCH

99-08-02

15:07:36

2980/00000

COMMANDFILE PROCESSING CONTINUATION


//
**********************************************
//
**
**
//
**
MASTERFILE : MF.CTY11.Z15075
**
//
**
**
//
**
ABORTED
**
//
**
ABGEBROCHEN
**
//
**
ABORTADO
**
//
**
**
//
**********************************************

END TEXT JOB 1660





COMMANDFILE PROCESSING CONTINUATION
// *******************************************************
// **
**
// ** PRIMARY MASTERFILE : PM.CTY11.K50.P073
**
// **
ABORTED
**
// **
ABGEBROCHEN
**
// **
ABORTADO
**
// **
**
// *******************************************************
END TEXT JOB 1361

58

SN2040E6A01

Patchset Incorporation

Siemens

3.2 Undefined Interruption of the CMD-File Control


Situation:
A system error message occurs.
undefined interruption of the CMD- file control.
System state:
It is not guaranteed, that the individual patches are completely incorporated.
It can be expected that at least one patch is not completely incorporated.
Error diagnosis:


Indications for the triggering of the event (e.g. NSTART1)

and the order of events of the CMD- file

are available and can be evaluated.


Symptom files: PT., MLOG.
Additional error information: AutoPatch task manager protocol.
Error correction:
Check whether a patch is not completely incorporated:
Yes

CANCEL the patch.

Immediate action (if possible):


Fallback for patchset (AutoPatch ENM 3.2)
After a completed evaluation of the indications (possibly by next TAC level):
Classification of the error and initiate measurements to remove the error:


Was the error caused by the patchset incorporation ?


call next TAC level.

Other Errors:

call next TAC level with standard indications according to FR (Fault Report)
processing.

SN2040E6A01

59

Patchset Incorporation

Siemens

3.2.1 Example: CMD-File Interruption due to a HW Failure /


Recovery (from AutoPatch for NodeCommander)
3.2.1.1

Task Manager Protocol

Task Manager (ASWTASK) V302.01

Reportlist Printout

***** Patch Action (ASWINC) V302.01


***** Copyright (c) SIEMENS AG 1998
----------------------------------------------------------------------Installation name : ICN VZ TI
Function
: NE Action: x677
Start Function
: 99.08.02 - 15:47:22
AICOM: + user - patch / NE - x677(ctycpz1v1150)
AICOM: + Authentication!
AICOM: + Session established!
AICOM: DISP MD;
AICOM: + Command accepted!
AICOM: + F1 Label: 234
AICOM: + F1 Label: check ok
***** Patch Action (ASWINC) V302.01
***** Copyright (c) SIEMENS AG 1998
----------------------------------------------------------------------Installation name : ICN VZ TI
Function
: NE Action: x677
Start Function
: 99.08.02 - 15:48:30
AICOM: + Transfer and start command file!
AICOM: + user - patch / NE - x677(ctycpz1v1150)
AICOM: + Authentication!
AICOM: + Session established!
AICOM: DISPGEN;
AICOM: + Command accepted!
AICOM:
TRANSFILE:FILE=073x677.pm,PRONAM=/"EMNOS1",USINF="akusw",MODE=OVWR,COPMOD=C
HAR;
AICOM: + Command accepted!
AICOM: + NE job number: 387
AICOM: DISPTIME;
AICOM: + Command accepted!
AICOM: + NE date - 99-08-02 / NE time - 16:14:52
AICOM: + NE APS - CTYCPZ1V1150/P71/003
AICOM: EXECCMDFILE:FILE=073x677.pm;
AICOM: + Command accepted!
AICOM: + NE job number: 391
AICOM: + No event!
***** Patch Action (ASWINC) V302.01
***** Copyright (c) SIEMENS AG 1998
-----------------------------------------------------------------------

60

SN2040E6A01

Patchset Incorporation

Siemens

Installation name : ICN VZ TI


Function
: NE Action: x677
Start Function
: 99.08.02 - 15:50:48
AICOM: + user - patch / NE - x677(ctycpz1v1150)
AICOM: + Authentication!
AICOM: + Session established!
AICOM: DISPJOB:JN=391;
AICOM: + Command accepted!
AICOM: + Last job check: 16:16:58
AICOM: + NE job: running
***** Patch Action (ASWINC) V302.01
***** Copyright (c) SIEMENS AG 1998
----------------------------------------------------------------------Installation name : ICN VZ TI
Function
: NE Action: x677
Start Function
: 99.08.02 - 15:55:32
AICOM: + user - patch / NE - x677(ctycpz1v1150)
AICOM: + Authentication!
AICOM: + Session established!
AICOM: DISPJOB:JN=391;
AICOM: + Command accepted!
AICOM: + Last job check: 16:21:41
AICOM: + NE job: running
***** Patch Action (ASWINC) V302.01
***** Copyright (c) SIEMENS AG 1998
----------------------------------------------------------------------Installation name : ICN VZ TI
Function
: NE Action: x677
Start Function
: 99.08.02 - 16:00:15
AICOM: + user - patch / NE - x677(ctycpz1v1150)
AICOM: + Authentication!
AICOM: + Session established!
AICOM: DISPJOB:JN=391;
AICOM: ! Command not accepted!
AICOM: ! Disconnected!
AICOM: + NE job: running
***** Patch Action (ASWINC) V302.01
***** Copyright (c) SIEMENS AG 1998
----------------------------------------------------------------------Installation name : ICN VZ TI
Function
: NE Action: x677
Start Function
: 99.08.02 - 16:06:08
AICOM: + user - patch / NE - x677(ctycpz1v1150)
AICOM: + Authentication!
AICOM: + Session established!
AICOM: DISPJOB:JN=391;
AICOM: + Command accepted!
AICOM: + NE job: finished
NE HANDLER: ! job: time out
NE HANDLER: ! LOCAL NE ERROR!
End
Function
: 99.08.02 - 17:44:15

SN2040E6A01

61

Patchset Incorporation

Siemens

3.2.1.2

MLOG

X677/CTYCPZ1V1150/P75/013
0025

3095/02107

99-08-02 16:22:05
HF.ARCHIVE-10829

FCP RECOVERY REPORT


ACTUAL CONFIGURATION: UNIT
OST LOAD DEVICE
-------+----+----------MDD-00 ACT YES
MDD-01 MBL NO
ACTUAL GENERATION

: NAME
CREATION DATE
LAST CREATED
---------+------------------+-----------11500104 99-05-05 07:37:34 NO

END TEXT JOB 0025

X677/CTYCPZ1V1150/P75/013
0044

3095/07901

99-08-02 16:22:10
HF.ARCHIVE-10830
MASKNO:07901

SSP

RECOVERY INFORMATION

REASON

: HARDWARE ERROR
ALARM SWITCHOVER

DATE
TIME
UNIT

: 02-08-99
: 16:22:00
: BAPM

REQUESTED RECOVERY LEVEL : NSTART0


PERFORMED RECOVERY LEVEL : NSTART0
CALLPROCESSING STARTED
RECOVERY DURATION
RESULT

:
:

SECONDS

: RECOVERY TERMINATED WITHOUT FAILURE


MASKNO:07896

SW MODULE
ERROR NUMBER
INTERRUPT ADDRESS
INTERRUPT LEVEL

:
:
:
:

STATISTICS OF SW ERROR TREATMENT


-------------------------------ERROR COUNTER
: 1
THRESHOLD
: 3
INTERVAL TIME (SEC): 600
END JOB 0044 EXEC'D

62

SN2040E6A01

Patchset Incorporation

Siemens

X677/CTYCPZ1V1150/P75/013
0025

3095/02100

99-08-02 16:22:11
HF.ARCHIVE-10831

FCP UPDATE REPORT


LAST EXECUTED TRANSACTION : DATE = 99-08-02 16:21:53
JOBNO= 0020
FILES UPDATED BY LAST TRANSACTION :
FILENAME:
GENERATION:
----------------------------------SY.SEMILIB
11500104
END TEXT JOB 0025

X677/CTYCPZ1V1150/P75/013
0037

3084/02073

99-08-02 16:22:45
HF.ARCHIVE-10832

CP113C FAILURE WITHOUT CONFIGURATION


ERROR REPORT
FAULT LOCATION: BAP-0
FAULT INFORMATION:

99-08-02

16:22:00

BCMY-0
ACT
BAP-0 H'00000001 IOC-0
H'00000000
H'00000000
H'00000000
CMY-0 H'00000000 CMY-1

H'00000000 BAP-1
H'00000000
H'00000000
H'00000000
H'00000000

H'00000000 IOC-1
H'00000000
H'00000000
H'00000000

H'00000000
H'00000000
H'00000000
H'00000000

BCMY-1
ACT
BAP-0 H'00000001 IOC-0
H'00000000
H'00000000
H'00000000
CMY-0 H'00000000 CMY-1

H'00000000 BAP-1
H'00000000
H'00000000
H'00000000
H'00000000

H'00000000 IOC-1
H'00000000
H'00000000
H'00000000

H'00000000
H'00000000
H'00000000
H'00000000

UNIT
OST
ALR
WST
---------+------+-------------+------BAP-0
MAS
H'00080008
IOC-0
ACT
H'00000000
IOC-1
ACT
H'00000000
CMY-0
ACT
H'00000000
CMY-1
ACT
H'00000000
END TEXT JOB 0037 EXEC'D

SN2040E6A01

63

Patchset Incorporation

Siemens

3.2.1.3

PT. Symptom File

DISPFILE:FILE=PT.;
USED SPACE :

EXEC'D
100 PAGES FOR

1 FILES

FILE
GEN
SIZE
VSN000
VSN001
CLASS TYPE
-----------------+--------+-------+-------------+-------------+----+---PT.AP.18
100
X
TEMP SAM
END JOB 0411
DISPFILETEXT
0412
FILE=
PT.AP.18;

X677/CTYCPZ1V1150/P75/013
0412
OMT-00/EWSD0

99-08-02

16:38:53

2970/06247

NOTES: - UNPRINTABLE CHARACTERS ARE SUBSTITUTED BY '.'


- CONTINUATION LINES OF A RECORD START WITH '>>'
----+----1----+----2----+----3----+----4----+----5----+----6----+----7-X677/CTYCPZ1V1150/P71/003
99-08-02 16:20:05
0686
csfs2/PATCH
2978/00006
SKIPCMD:LABEL=CRERROR,ON=32;
END TEXT JOB 0686

X677/CTYCPZ1V1150/P71/003
0687
csfs2/PATCH

STARTED

99-08-02

SKIPCMD:LABEL=EXECUTE;
END TEXT JOB 0687

X677/CTYCPZ1V1150/P71/003
0688
csfs2/PATCH

STARTED

99-08-02

EXEC'D

99-08-02

64

16:20:05

2967/01767

DELFILE:FILE=PT.AP.;
END TEXT JOB 0689

X677/CTYCPZ1V1150/P71/003
0689
csfs2/PATCH

16:20:05

2977/00007

SETCFOPT:OFF=2&16;
END JOB 0688

X677/CTYCPZ1V1150/P71/003
0689
csfs2/PATCH

16:20:05

2978/00006

ACCEPTED

99-08-02

16:20:05

2969/01766

SN2040E6A01

Patchset Incorporation

Siemens

DELFILE:FILE=PT.AP.;

NOT EXEC'D

FILE
ERROR INFORMATION
-----------------------------------------------------------------------PT.AP.18
FILE IN USE
END JOB 0689

X677/CTYCPZ1V1150/P71/003
0391
csfs2/PATCH

99-08-02

16:20:05

2980/00000

COMMANDFILE PROCESSING CONTINUATION


//
********************************************************
//
** PATCHSET RELEASED AT: 1999.05.04 12:27
**
//
**
**
//
**
STARTED
**
//
** PRIMARY MASTERFILE : PM.CTY11.K50.P073 GESTARTET **
//
**
ARRANCADO **
//
**
**
//
********************************************************
END TEXT JOB 0391

X677/CTYCPZ1V1150/P71/003
0691
csfs2/PATCH

99-08-02

EXECCMDFILE:FILE=MF.CTY11.Z15075;
END TEXT JOB 0691

X677/CTYCPZ1V1150/P71/003
0692
csfs2/PATCH

STARTED

99-08-02

16:20:06

2977/00007

SETCFOPT:ACKCFS=ERROR,OFF=16,DANCMD=EXEC,ACKREQ=POS;
END JOB 0692

X677/CTYCPZ1V1150/P71/003
0691
csfs2/PATCH

16:20:06

2978/00006

EXEC'D

99-08-02

16:20:07

99-08-02

16:20:07

2980/00000

COMMANDFILE PROCESSING CONTINUATION


//
**********************************************
//
** PATCHSET RELEASED AT: 1999.05.04 12:27
**
//
**
**
//
**
STARTED
**
//
** MASTERFILE : MF.CTY11.Z15075 GESTARTET **
//
**
ARRANCADO **
//
** LOADTYPE
:
**
//
**
**
//
**********************************************
END TEXT JOB 0691

X677/CTYCPZ1V1150/P71/003
0693
csfs2/PATCH

2978/00006

EXECCMDFILE:FILE=PA.W1189L2Z.V0001,STEP;
END TEXT JOB 0693

SN2040E6A01

STARTED

65

Patchset Incorporation

Siemens

SETCFOPT:ACKCFS=ERROR,OFF=16,DANCMD=EXEC,ACKREQ=POS;
END JOB 0694

X677/CTYCPZ1V1150/P71/003
0693
csfs2/PATCH

EXEC'D

99-08-02

16:20:07

2980/00000

COMMANDFILE PROCESSING CONTINUATION


//
************************************************************
//
**
**
//
** COMMANDFILE FOR PATCH APSLMY00.W1189L2Z.0001.0 STARTED **
//
**
**
//
************************************************************
END TEXT JOB 0693

X677/CTYCPZ1V1150/P71/003
0695
csfs2/PATCH

99-08-02

ENTRCPPRPCH:ID="APSLMY00.W1189L2Z.0001.0",INSRADDR=
"BBSCPA0C.PID2PA6C_1617+H'761A"&&"+H'6",SUBPPART=1-LAST,
NEWCNT=
"9FFC000000040C280003001866184A28001966124A2E0026670CDFFC000
000044EF9.A(B"&
"BSCPA0C.PID2PA6C_1617+H'7628)DFFC000000042D48FF184EF9.A(BBS
CPA0C.PID2PA6"&"C_1617+H'7636)",OLDCNT="0C2800030018";
END TEXT JOB 0695

X677/CTYCPZ1V1150/P71/003
0695
csfs2/PATCH

99-08-02

66

16:20:15

99-08-02

EXEC'D

16:20:15

3087/06977

ENTRCPPRPCH:ID="APSLMY00.W1189L2Z.0001.0",INSRADDR=
"BBSCPA0C.PID2PA6C_1617+H'761A"&&"+H'6",SUBPPART=1-LAST,
NEWCNT=
"9FFC000000040C280003001866184A28001966124A2E0026670CDFFC000
000044EF9.A(B"&
"BSCPA0C.PID2PA6C_1617+H'7628)DFFC000000042D48FF184EF9.A(BBS
CPA0C.PID2PA6"&"C_1617+H'7636)",OLDCNT="0C2800030018";
END JOB 0695

SKIPCMD:LABEL=ERROR0,ON=32;
END TEXT JOB 0716

EXEC'D

3087/07695

ENTRCPPRPCH:ID="APSLMY00.W1189L2Z.0001.0",INSRADDR=
"BBSCPA0C.PID2PA6C_1617+H'761A"&&"+H'6",SUBPPART=1-LAST,
NEWCNT=
"9FFC000000040C280003001866184A28001966124A2E0026670CDFFC000
000044EF9.A(B"&
"BSCPA0C.PID2PA6C_1617+H'7628)DFFC000000042D48FF184EF9.A(BBS
CPA0C.PID2PA6"&"C_1617+H'7636)",OLDCNT="0C2800030018";
END TEXT JOB 0695

X677/CTYCPZ1V1150/P71/003
0695
csfs2/PATCH

16:20:15

3087/06971

EXEC'D

STARTED

SN2040E6A01

Patchset Incorporation

Siemens

ENTRCPPRPCH:ID="APSLMY00.W1189L2Z.0001.0",SUBPCHNO=1;
END TEXT JOB 0717

X677/CTYCPZ1V1150/P71/003
0717
csfs2/PATCH

EXEC'D

99-08-02

ENTRCPPRPCH:ID="APSLMY00.W1189L2Z.0001.0",SUBPCHNO=1;
END TEXT JOB 0717

X677/CTYCPZ1V1150/P71/003
0717
csfs2/PATCH

EXEC'D

99-08-02

EXEC'D

99-08-02

STARTED

99-08-02

EXEC'D

99-08-02

EXEC'D

99-08-02

EXEC'D

99-08-02

SKIPCMD:LABEL=ERRORC,ON=32;
END TEXT JOB 0757

SN2040E6A01

16:20:30

3087/06977

UPDCPPRPCH:ID="APSLMY00.W1189L2Z.0001.0";
END JOB 0737

X677/CTYCPZ1V1150/P71/003
0757
csfs2/PATCH

16:20:30

3087/07695

UPDCPPRPCH:ID="APSLMY00.W1189L2Z.0001.0";
END TEXT JOB 0737

X677/CTYCPZ1V1150/P71/003
0737
csfs2/PATCH

16:20:30

3087/06971

UPDCPPRPCH:ID="APSLMY00.W1189L2Z.0001.0";
END TEXT JOB 0737

X677/CTYCPZ1V1150/P71/003
0737
csfs2/PATCH

16:20:28

3087/06971

UPDCPPRPCH:ID="APSLMY00.W1189L2Z.0001.0";
END TEXT JOB 0737

X677/CTYCPZ1V1150/P71/003
0737
csfs2/PATCH

16:20:22

2978/00006

SKIPCMD:LABEL=ERROR,ON=32;
END TEXT JOB 0736

X677/CTYCPZ1V1150/P71/003
0737
csfs2/PATCH

16:20:22

3087/06977

ENTRCPPRPCH:ID="APSLMY00.W1189L2Z.0001.0",SUBPCHNO=1;
END JOB 0717

X677/CTYCPZ1V1150/P71/003
0736
csfs2/PATCH

16:20:21

3087/07695

EXEC'D

99-08-02

16:20:30

2978/00006
STARTED

67

Patchset Incorporation

Siemens

INCRAPSVN;
END JOB 0758

X677/CTYCPZ1V1150/P72/003
0759
csfs2/PATCH

EXEC'D

99-08-02

16:20:31

2977/00007

RESETCFOPT;
END JOB 0759

EXEC'D

EXECCMDFILE:FILE=PA.W1189L2Z.V0001,STEP;
END TEXT JOB 0693

X677/CTYCPZ1V1150/P72/003
0760
csfs2/PATCH

FINISHED

99-08-02

16:20:31

2978/00006

SKIPCMD:LABEL=ERROR,ON=32;
END TEXT JOB 0760

X677/CTYCPZ1V1150/P72/003
0761
csfs2/PATCH

STARTED

99-08-02

16:20:31

2978/00006

SKIPCMD:LABEL=ERROR,ON=16;
END TEXT JOB 0761

X677/CTYCPZ1V1150/P72/003
0762
csfs2/PATCH

STARTED

99-08-02

16:20:31

2978/00006

EXECCMDFILE:FILE=PA.W6377L2Z.V0002,STEP;
END TEXT JOB 0762
X677/CTYCPZ1V1150/P72/003
0763
csfs2/PATCH

STARTED

99-08-02

16:20:31

2977/00007

SETCFOPT:ACKCFS=ERROR,OFF=16,DANCMD=EXEC,ACKREQ=POS;
END JOB 0763

X677/CTYCPZ1V1150/P72/003
0762
csfs2/PATCH

EXEC'D

99-08-02

16:20:31

2980/00000

COMMANDFILE PROCESSING CONTINUATION


//
************************************************************
//
**
**
//
** COMMANDFILE FOR PATCH APSLMY00.W6377L2Z.0002.0 STARTED **
//
**
**
//
************************************************************
END TEXT JOB 0762




68

SN2040E6A01

Patchset Incorporation

Siemens

COMMANDFILE PROCESSING CONTINUATION


//
************************************************************
//
**
**
//
** COMMANDFILE FOR PATCH APSLMY00.X4283L2Z.0001.0 STARTED **
//
**
**
//
************************************************************
END TEXT JOB 0822

X677/CTYCPZ1V1150/P73/003
0824
csfs2/PATCH

99-08-02

16:21:02

3087/06971

ENTRCPPRPCH:ID="APSLMY00.X4283L2Z.0001.0",INSRADDR=
"BBSCPA0C.PIDULA6C_1620+H'3B4"&&"+H'6",SUBPPART=1-LAST,
NEWCNT=
"422E001B0C2E0012000865340C2E00150008622C7000102E00080680FFF
FFFEEE9802079"&
".A(BBSCPA0C.PIDULA6C_1620+H'8)D0FC02C4226E001422114681EEF00
84108101D7C00"&
"01001B206E00144EF9.A(BBSCPA0C.PIDULA6C_1620+H'462)",OLDCNT=
"206E001420BC";
END TEXT JOB 0824



X677/CTYCPZ1V1150/P74/003
0888
csfs2/PATCH

99-08-02

EXEC'D

16:21:18

2980/00000

COMMANDFILE PROCESSING CONTINUATION


//
************************************************************
//
**
**
//
** COMMANDFILE FOR PATCH S@SWDDSL.X7316L2Z.0001.0 STARTED **
//
**
**
//
************************************************************
END TEXT JOB 0888

X677/CTYCPZ1V1150/P74/003
0890
csfs2/PATCH

99-08-02

ENTRCPPRPCH:ID="S@SWDDSL.X7316L2Z.0001.0",INSRADDR=
"S@SWDDSL.SWDDSA0C_0713+H'1DEC"&&"+H'6",SUBPPART=1-LAST,
NEWCNT="60FF.D(S@SWDDSL.SWDDSA0C_0713+H'1DFE)",OLDCNT=
"0C2E000F0064";
END TEXT JOB 0890



UPDCPPRPCH:ID="S@SWDDSL.X7316L2Z.0001.0";
END TEXT JOB 1019
X677/CTYCPZ1V1150/P74/003
1028
csfs2/PATCH
SKIPCMD:LABEL=ERRORC,ON=32;
END TEXT JOB 1028

SN2040E6A01

16:21:24

3087/06971

EXEC'D

EXEC'D

99-08-02

16:21:53

2978/00006
STARTED

69

Patchset Incorporation

Siemens

INCRAPSVN;
END JOB 1029

X677/CTYCPZ1V1150/P75/003
1030
csfs2/PATCH

EXEC'D

99-08-02

16:21:53

2977/00007

RESETCFOPT;
END JOB 1030

X677/CTYCPZ1V1150/P75/003
0888
csfs2/PATCH

EXEC'D

99-08-02

EXECCMDFILE:FILE=PA.X7316L2Z.V0001,STEP;
END TEXT JOB 0888

X677/CTYCPZ1V1150/P75/003
1031
csfs2/PATCH

16:21:53

2977/01274
FINISHED

99-08-02

16:21:54

2978/00006

SKIPCMD:LABEL=ERROR,ON=32;
END TEXT JOB 1031

X677/CTYCPZ1V1150/P75/003
1032
csfs2/PATCH

STARTED

99-08-02

16:21:54

2978/00006

SKIPCMD:LABEL=ERROR,ON=16;
END TEXT JOB 1032

X677/CTYCPZ1V1150/P75/003
1033
csfs2/PATCH

STARTED

99-08-02

16:21:54

2978/00006

EXECCMDFILE:FILE=PA.X9157L2Z.V0001,STEP;
END TEXT JOB 1033

X677/CTYCPZ1V1150/P75/003
1034
csfs2/PATCH

STARTED

99-08-02

16:21:54

2977/00007

SETCFOPT:ACKCFS=ERROR,OFF=16,DANCMD=EXEC,ACKREQ=POS;
END JOB 1034

EXEC'D

COMMANDFILE PROCESSING CONTINUATION


//
************************************************************
//
**
**
//
** COMMANDFILE FOR PATCH APSLMY00.X9157L2Z.0001.0 STARTED **
//
**
**
//
************************************************************
END TEXT JOB 1033
END JOB 0412 EXEC'D

70

SN2040E6A01

Patchset Incorporation

Siemens

3.2.2 Example: CMD-File Interruption due to a HW Failure /


Recovery (from AutoPatch Light)
3.2.2.1

MLOG

EXECCMDFILE
0189
FILE=
073CTY11.PM
STEP=
;
X677/CTYCPZ1V1150/P67/003
0189
OMT-00/EWSD0

99-08-02

EXECCMDFILE:FILE=073CTY11.PM;
END TEXT JOB 0189

X677/CTYCPZ1V1150/P67/003
0201(0189)
OMT-00/EWSD0

STARTED

99-08-02

STARTED

99-08-02

14:15:59

2977/00007

SETCFOPT:ACKCFS=ERROR,OFF=16,DANCMD=EXEC,ACKREQ=POS;
END JOB 0202

X677/CTYCPZ1V1150/P67/003
0189
OMT-00/EWSD0

14:15:58

2978/00006

SKIPCMD:LABEL=MASTER,ON=2;
END TEXT JOB 0201

X677/CTYCPZ1V1150/P67/003
0202(0189)
OMT-00/EWSD0

14:15:57

2978/00006

EXEC'D

99-08-02

14:16:01

2980/00000

COMMANDFILE PROCESSING
//
********************************************************
//
** PATCHSET RELEASED AT: 1999.05.04 12:27
**
//
**
**
//
**
STARTED
**
//
** PRIMARY MASTERFILE : PM.CTY11.K50.P073 GESTARTET **
//
**
ARRANCADO **
//
**
**
//
********************************************************
END TEXT JOB 0189

SN2040E6A01

71

Patchset Incorporation

Siemens

FCP RECOVERY REPORT


ACTUAL CONFIGURATION: UNIT
OST LOAD DEVICE
-------+----+----------MDD-00 ACT YES
MDD-01 MBL NO
ACTUAL GENERATION

: NAME
CREATION DATE
LAST CREATED
---------+------------------+-----------11500104 99-05-05 07:37:34 NO

END TEXT JOB 0024

X677/CTYCPZ1V1150/P69/013
0024

3095/02100

99-08-02 14:17:00
HF.ARCHIVE-10822

FCP UPDATE REPORT


LAST EXECUTED TRANSACTION : DATE = 99-08-02 14:16:49
JOBNO= 0020
FILES UPDATED BY LAST TRANSACTION :
FILENAME:
GENERATION:
----------------------------------SY.SEMILIB
11500104
END TEXT JOB 0024

X677/CTYCPZ1V1150/P69/013
0043

3095/07901

99-08-02 14:17:05
HF.ARCHIVE-10823
MASKNO:07901

SSP

RECOVERY INFORMATION

REASON

: HARDWARE ERROR
ALARM SWITCHOVER

DATE
TIME
UNIT

: 02-08-99
: 14:16:54
: BAPM

REQUESTED RECOVERY LEVEL : NSTART0


PERFORMED RECOVERY LEVEL : NSTART1
CALLPROCESSING STARTED
RECOVERY DURATION
RESULT

: 14:16:57
:
3
SECONDS

: RECOVERY TERMINATED WITHOUT FAILURE


MASKNO:07902

SUPPLEMENTARY INFORMATION :
ESCALATION BY HW/SW ERROR STATISTICS
APS GENERATION : 11500104

72

SN2040E6A01

Patchset Incorporation

Siemens

CRITICAL STATES
--------------NO (MORE) DATA FOR DISPLAY AVAILABLE
MASKNO:07896
SW MODULE
ERROR NUMBER
INTERRUPT ADDRESS
INTERRUPT LEVEL

:
:
:
:

STATISTICS OF SW ERROR TREATMENT


-------------------------------ERROR COUNTER
: 1
THRESHOLD
: 2
INTERVAL TIME (SEC): 600
END JOB 0043 EXEC'D

X677/CTYCPZ1V1150/P69/013
0036

3084/02073

99-08-02 14:17:40
HF.ARCHIVE-10824

CP113C FAILURE WITHOUT CONFIGURATION


ERROR REPORT
FAULT LOCATION: BAP-0
FAULT INFORMATION:

99-08-02

14:16:54

BCMY-0
ACT
BAP-0 H'00000001 IOC-0
H'00000000
H'00000000
H'00000000
CMY-0 H'00000000 CMY-1

H'00000000 BAP-1
H'00000000
H'00000000
H'00000000
H'00000000

H'00000000 IOC-1
H'00000000
H'00000000
H'00000000

H'00000000
H'00000000
H'00000000
H'00000000

BCMY-1
ACT
BAP-0 H'00000001 IOC-0
H'00000000
H'00000000
H'00000000
CMY-0 H'00000000 CMY-1

H'00000000 BAP-1
H'00000000
H'00000000
H'00000000
H'00000000

H'00000000 IOC-1
H'00000000
H'00000000
H'00000000

H'00000000
H'00000000
H'00000000
H'00000000

UNIT
OST
ALR
WST
---------+------+-------------+------BAP-0
MAS
H'00080008
IOC-0
ACT
H'00000000
IOC-1
ACT
H'00000000
CMY-0
ACT
H'00000000
CMY-1
ACT
H'00000000
END TEXT JOB 0036 EXEC'D

SN2040E6A01

73

Patchset Incorporation

Siemens

3.2.2.2

PT. Symptom File

DISPFILE:FILE=PT.;

USED SPACE :

EXEC'D

100 PAGES FOR

1 FILES

FILE
GEN
SIZE
VSN000
VSN001
CLASS TYPE
-----------------+--------+-------+-------------+-------------+----+---PT.CTY11.K50.P073
100
X
TEMP SAM
END JOB 0094
DISPFILETEXT
0100
FILE=
PT.CTY11.K50.P073
READY TO EXECUTE <
;

X677/CTYCPZ1V1150/P69/013
0100
OMT-00/EWSD0

99-08-02

14:18:35

2970/06247

NOTES: - UNPRINTABLE CHARACTERS ARE SUBSTITUTED BY '.'


- CONTINUATION LINES OF A RECORD START WITH '>>'
----+----1----+----2----+----3----+----4----+----5----+----6----+----7-X677/CTYCPZ1V1150/P67/003
99-08-02 14:16:00
0204
OMT-00/EWSD0
2978/00006
SKIPCMD:LABEL=CRERROR,ON=32;
STARTED
END TEXT JOB 0204



COMMANDFILE PROCESSING
//
********************************************************
//
** PATCHSET RELEASED AT: 1999.05.04 12:27
**
//
**
**
//
**
STARTED
**
//
** PRIMARY MASTERFILE : PM.CTY11.K50.P073 GESTARTET **
//
**
ARRANCADO **
//
**
**
//
********************************************************
END TEXT JOB 0189

X677/CTYCPZ1V1150/P67/003
0207
OMT-00/EWSD0
EXECCMDFILE:FILE=MF.CTY11.Z15075;
END TEXT JOB 0207

74

99-08-02

14:16:02

2978/00006
STARTED

SN2040E6A01

Patchset Incorporation

Siemens

SETCFOPT:ACKCFS=ERROR,OFF=16,DANCMD=EXEC,ACKREQ=POS;
END JOB 0208

X677/CTYCPZ1V1150/P67/003
0207
OMT-00/EWSD0

EXEC'D

99-08-02

14:16:02

99-08-02

14:16:02

2980/00000

COMMANDFILE PROCESSING CONTINUATION


//
**********************************************
//
** PATCHSET RELEASED AT: 1999.05.04 12:27
**
//
**
**
//
**
STARTED
**
//
** MASTERFILE : MF.CTY11.Z15075 GESTARTET **
//
**
ARRANCADO **
//
** LOADTYPE
:
**
//
**
**
//
**********************************************
END TEXT JOB 0207

X677/CTYCPZ1V1150/P67/003
0209
OMT-00/EWSD0

2978/00006

EXECCMDFILE:FILE=PA.W1189L2Z.V0001,STEP;
END TEXT JOB 0209

X677/CTYCPZ1V1150/P67/003
0210
OMT-00/EWSD0

STARTED

99-08-02

14:16:03

2977/00007

SETCFOPT:ACKCFS=ERROR,OFF=16,DANCMD=EXEC,ACKREQ=POS;
END JOB 0210

X677/CTYCPZ1V1150/P67/003
0209
OMT-00/EWSD0

EXEC'D

99-08-02

14:16:03

2980/00000

COMMANDFILE PROCESSING CONTINUATION


//
************************************************************
//
**
**
//
** COMMANDFILE FOR PATCH APSLMY00.W1189L2Z.0001.0 STARTED **
//
**
**
//
************************************************************
END TEXT JOB 0209



COMMANDFILE PROCESSING CONTINUATION
//
************************************************************
//
**
**
//
** COMMANDFILE FOR PATCH APSLMY00.W6377L2Z.0002.0 STARTED **
//
**
**
//
************************************************************
END TEXT JOB 0269

SN2040E6A01

75

Siemens

Patchset Incorporation

ENTRCPPRPCH:ID="APSLMY00.W6377L2Z.0002.0",INSRADDR=
"BBSCPA0C.TSPROA0C_4001+H'42C"&&"+H'6",SUBPPART=1-LAST,
NEWCNT=
"4A2EFC686716204E508843EEFC6CB189660AB18966064EF9.A(BBSCPA0C
.TSPROA0C_400"&
"1+H'43C)4EF9.A(BBSCPA0C.TSPROA0C_4001+H'442)",OLDCNT=
"204E508843EE";

EXEC'D




COMMANDFILE PROCESSING CONTINUATION
//
************************************************************
//
**
**
//
** COMMANDFILE FOR PATCH APSLMY00.X4283L2Z.0001.0 STARTED **
//
**
**
//
************************************************************

END TEXT JOB 0339


END JOB 0100 EXEC'D

76

SN2040E6A01

Patchset Incorporation

Siemens

3.3 Conventions
3.3.1 Patch Name Conventions
The patch ID is composed of several groups:
CAPSULENAME . PATCHNAME . VERSION . SEQUENCE NUMBER
E.g.: APSLMY00.W1189L2Z.0001.0
CAPSULE names
for modules in CMY:

APSCMY00

for modules in LMY:

APSLMY00

for loadable SW:

S@XXXXXL (XXXXX= process name)

for PSW-Files:

TXXX@@@@ (XXX= loadtype)

PATCH name for global PAT patches: nnnnnvvt (e.g. W1189L2Z)


nnnnn

Patch number (automatically given by the patch


development tool)

vv

Patch variant

Patch type

vv

L0

MP

Z,J

L2

CP

Z,J

L3

IOP

Z,J

D,Z = active patch

L4

LTG

D,K

K,J= backout patch

L7

free format (CP)

O1

AMX

Z,J

N1

IWU

Z,J

N2

LIC

Z,J

N4

CCNC

Z,J

VERSION

Automatically given by the patch development tool.

SEQUENCE NUMBER

Sequence number for patches with the same ID.

SN2040E6A01

77

Siemens

Patchset Incorporation

3.3.2 File Name Conventions (AutoPatch)


SW Manager Information window


PM.***...
Refers to a Primary Master File, a control file for incorporating patches. All Master
Files are called and executed one after the other when this file is executed.
E.g.: PF.DBP21.K31.N07
DBP21 = system version designation
K31 = patch status of installation as of time of delivery to customer
N07 = patch set name

MF.***...
Refers to a Master File. Master Files are control files for incorporating patches.
They cause the corresponding patches to be transferred and incorporated to the
selected NE.
E.g.: MF.DBP21.V31308

PA.***...
Refers to a patch file. These files contain the actual software correction, i.e. the
code that is incorporated in the software on the NE.
E.g.: PA.A30323L2Z.V0001
A30323L2Z.V0001 = Patchname

PD.***...
Refers to files within a patch set that contain the incorporation instructions to be
followed. Before a patch set in incorporated, they are automatically displayed. If
such a file is empty, this means no special measures have to be taken.
E.g.: PD.DBP21.K31.PN07

<listname>.txt
This file contains all files of a patch set (patches, master files, primary master files)
that are written to a file in alphabetical order. The contents of this collective file
can be displayed with the Display function.

78

SN2040E6A01

Patchset Incorporation

Siemens

Pool Window


*.dps
This extension refers to patch sets that still have to be imported and contain the
actual software corrections. Files supplied by CASINO also have this ending, but
can also contain several patch sets that are to be imported.

*.bhw
Refers to a text file with information required for operating the system. After
importation, these files are located in the /usr/akusw/bhw directory.

basis.unl
Refers to basic files that contain information on the connected NEs and the patch
status of the installation as of the time of delivery to the customer.

Other Windows


*.sid
Status and inventory data files which contain information on the installation, such
as how they can be called via available lists. They are used for forwarding this
information to the super ordinate service level.

*.ifh
Refers to an error symptom file. In the case of an NE failure, these files are
generated directly at the NE and can be forwarded to a super ordinate service
level with the help of AutoPatch.

SN2040E6A01

79

Siemens

80

Patchset Incorporation

SN2040E6A01