PSL
Power Standards Lab
2020 Challenger Drive #100
Alameda, CA 94501 USA
TEL ++1-510-522-4400
FAX ++1-510-522-4455
www.PowerStandards.com
Certificate of Conformity
IEC 61000-4-30 Class A
A-Eberle PQ Box 100 and PQ Box 200
when equipped with the following accessories or options:
GPS satellite receiver Art. 111.9024.45
Class A
Compliance
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Class S
Compliance
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
(N/A)
Class B
Compliance
Yes
Yes
(N/A)
Yes
Yes
Yes
Yes
Yes
Yes
(N/A)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
(N/A)
Yes
(N/A)
(N/A)
Remarks
This certificate summarizes the results of the PSL IEC 61000-4-30 Power Quality Measurement
Methods Compliance Report, document #PSL 61000-4-30 Ed 2 Test Report A-Eberle
PQBox100-200, dated 7 August 2013. PSL tested two samples, S/N 1320-101 and 1317-105, at
230VAC, 50/60 Hz. Manufacturer states that these samples are representative of the PQ Box
series.
________________________________
Alex McEachern
7 August 2013
Alex@PowerStandards.com
PSL Document PSL 61000-4-30 CLASS A Certificate - iSTATM355 - ALSTOM - Final- Last update 8/14/2014
PSL
Power Standards Lab
2020 Challenger Drive #100
Alameda, CA 94501 USA
TEL ++1-510-522-4400
FAX ++1-510-522-4455
www.PowerStandards.com
Certificate of Conformity
IEC 61000-4-30 Class A
ALSTOM iSTAT M355
with compatible GPS receiver or NTP server
Class A
Compliance
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Class S
Compliance
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
(N/A)
Class B
Compliance
Yes
Yes
(N/A)
Yes
Yes
Yes
Yes
Yes
Yes
(N/A)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
(N/A)
Yes
(N/A)
(N/A)
Remarks
This certificate summarizes the results of the PSL IEC 61000-4-30 Power Quality Measurement
Methods Compliance Report, document #PSL 61000-4-30 Ed 2 Test Report iSTAT M355
ALSTOM, dated 11 July 2014. PSL tested two samples, S/N MC015976 and MC015975, at
230VAC, 50/60 Hz. Manufacturer states that these samples are representative of the iSTAT
M355 series.
_______________________________
Alex McEachern
14 August 2014
Alex@PowerStandards.com
PSL Document PSL 61000-4-30 CLASS A Certificate - Nexus 1500.doc - Last update 1/11/2010
PSL
Power Standards Lab
1201 Marina Village Parkway #101
Alameda, CA 94501 USA
TEL ++1-510-522-4400
FAX ++1-510-522-4455
www.PowerStandards.com
Certificate of Conformity
IEC 61000-4-30 Class A
Electro Industries Nexus 1500
equipped with compatible IRIG-B GPS receiver
IEC 61000-4-30 Ed. 2
230V, 50/60 Hz, L-N Udin
61000-4-30
Section
5.1
5.2
5.3
5.4
5.5
5.7
5.8
5.9
5.10
5.12
4.4
4.6
4.7
6.1
Class A
Compliance
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Class S
Compliance
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
(N/A)
Class B
Compliance
Yes
Yes
(N/A)
Remarks
Yes
Yes
Yes
Yes
Yes
(N/A)
Yes
Yes
Yes
(N/A)
(N/A)
This certificate summarizes the results of the PSL IEC 61000-4-30 Power Quality Measurement
Methods Compliance Report, PSL document # ELIND-001, dated 11 January 2010. PSL tested
one sample, S/N 910-0035301315 at 230VAC, 50/60 Hz. Manufacturer states that this sample is
representative of the Nexus 1500 series.
________________________________
Alex McEachern
11 January 2010
Alex@PowerStandards.com
.
Electro Industries Nexus 1500
PSL Document PSL 61000-4-30 CLASS A Certificate - Final - ELSPEC 4400 and 4500-3500.doc - Last update 8/17/2010
PSL
Power Standards Lab
1201 Marina Village Parkway #101
Alameda, CA 94501 USA
TEL ++1-510-522-4400
FAX ++1-510-522-4455
www.PowerStandards.com
Certificate of Conformity
IEC 61000-4-30 Class A
ELSPEC 4400 series (443x/442x/441x) and 4500/3500 series
IEC 61000-4-30 Ed. 2
230V, 50/60 Hz, L-N Udin
61000-4-30
Section
5.1
5.2
5.3
5.4
5.5
5.7
5.8
5.9
5.10
5.12
4.4
4.6
4.7
6.1
Class A
Compliance
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Class S
Compliance
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
(N/A)
Yes
Yes
Yes
(N/A)
Class B
Compliance
Yes
Yes
(N/A)
Yes
Yes
Yes
Yes
Yes
(N/A)
Yes
Yes
(N/A)
(N/A)
Remarks
See Note 1
This certificate summarizes the results of the PSL IEC 61000-4-30 Power Quality Measurement
Methods Compliance Report, document # PSL ELSPEC-005-30, dated 17 August 2010. PSL
tested two samples, Model G4420 S/N 00-60-35-03-46-96 and Model G4500 S/N 00-60-35-0B96-D6 at 230VAC, 50/60 Hz. Manufacturer states that these samples are representative of the
ELSPEC 4400 (443x/442x/441x) and 4500/3500 series.
________________________________
Alex McEachern
17 August 2010
Alex@PowerStandards.com
Left: ELSPEC G4420
Right: ELSPEC G4500
PSL
Power Standards Lab
1201 Marina Village Parkway #101
Alameda, CA 94501 USA
TEL ++1-510-522-4400
FAX ++1-510-522-4455
www.PowerStandards.com
Certificate of Conformity
IEC 61000-4-30 Ed. 2 Class A
Fluke 1760
equipped with Voltage Probes 600V and
Garmin GPS18 LVC GPS Receiver
(or other GPS receiver with equivalent accuracy and functionality)
Class A
Compliance
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Class S
Compliance
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Class B
Compliance
Yes
Yes
(N/A)
(N/A)
Yes
Yes
Yes
Yes
Yes
(N/A)
Remarks
(N/A)
Yes
Yes
Yes
Yes
Yes
Yes
(N/A)
(N/A)
This certificate summarizes the results of the PSL IEC 61000-4-30 Power Quality Measurement
Methods Compliance Report, document # PSL FLUKE-003-30a, dated 17 May 2007 and
Addendum 1 for Ed. 2 Update, dated 29 October 2010. PSL tested one sample, S/N
V7-59941-IC at 230VAC, 50/60 Hz. Manufacturer states that this sample is representative of the
FLUKE 1760 series.
________________________________
FLUKE 1760
Alex McEachern
29 October 2010
Alex@PowerStandards.com
PSL
Power Standards Lab
2020 Challenger Drive #100
Alameda, CA 94501 USA
TEL ++1-510-522-4400
FAX ++1-510-522-4455
www.PowerStandards.com
Certificate of Conformity
IEC 61000-4-30 Class A, Class S, and Class B
PSL PQube
with Firmware 1.5 or later
Class A
Compliance
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
All except
150/180
Yes
Yes
Yes
Class S
Compliance
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
All except
150/180
Yes
Yes
(N/A)
Class B
Compliance
Yes
Yes
(N/A)
Yes
Yes
Yes
Yes
Yes
-
Remarks
See Section 4.4
At 230V 50Hz
Yes
Yes
(N/A)
(N/A)
See Note 3
Pass
Pass
This certificate summarizes the results of the PSL IEC 61000-4-30 Power Quality Measurement
Methods Compliance Report, document # PSL PSL-001-30, dated 8 February 2011. PSL tested
S/N P002887 at 230V 50Hz. Manufacturer states this sample is representative of the PQube.
________________________________
Alex McEachern
8 February 2011
Alex@PowerStandards.com
.
PSL PQube
PSL
Power Standards Lab
1201 Marina Village Parkway #101
Alameda, CA 94501 USA
TEL ++1-510-522-4400
FAX ++1-510-522-4455
www.PowerStandards.com
Certificate of Conformity
IEC 61000-4-30 Class A
Siemens SIMEAS Q80
equipped with Garmin GPS18x LVC
(or other GPS receiver with equivalent accuracy and functionality)
IEC 61000-4-30 Ed. 2
230V, 50/60 Hz, L-N Udin
61000-4-30
Section
5.1
5.2
5.3
5.4
5.5
5.7
5.8
5.9
5.10
5.12
Class A
Compliance
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
-
Class S
Compliance
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
-
Class B
Compliance
Yes
Yes
Yes
4.4
Yes
No
4.6
4.7
6.1
Time-clock uncertainty
Flagging
Transient influence quantities
Yes
Yes
Yes
Yes
Yes
(N/A)
(N/A)
Remarks
Yes
Yes
Yes
Yes
Yes
Yes
Yes
(N/A)
(N/A)
This certificate summarizes the results of the PSL IEC 61000-4-30 Power Quality Measurement
Methods Compliance Report, document # PSL SIEMENS-009-30, dated 27 August 2009. PSL
tested two samples, S/N 140148 and 140149 at 230VAC, 50/60 Hz. Manufacturer states that
these samples are representative of the SIMEAS Q80 series.
________________________________
Alex McEachern
27 August 2009
Alex@PowerStandards.com
.
Siemens SIMEAS Q80
61000-4-30 CLASS A Certificate - PQM-702, 703, 710 and 711 - Sonel_Final Last update 11/17/2014
PSL
Power Standards Lab
2020 Challenger Drive #100
Alameda, CA 94501 USA
TEL ++1-510-522-4400
FAX ++1-510-522-4455
www.PowerStandards.com
Certificate of Conformity
IEC 61000-4-30 Class A
SONEL PQM-702, PQM-703, PQM-710 & PQM-711 Series
with compatible GPS antenna
Class A
Compliance
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Class S
Compliance
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
(N/A)
Class B
Compliance
Yes
Yes
(N/A)
Yes
Yes
Yes
Yes
Yes
Yes
(N/A)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
(N/A)
Yes
(N/A)
(N/A)
Remarks
This certificate summarizes the results of the PSL IEC 61000-4-30 Power Quality Measurement
Methods Compliance Report, document #PSL 61000-4-30 Ed 2 Test Report Sonel PQM dated
30 September 2014. PSL tested two samples, Model PQM-702 S/N AZ0191 & PQM-711 S/N
BS0009, at 230VAC, 50/60 Hz. Manufacturer states that these samples are representative of the
PQM-702, PQM-703, PQM-710 & PQM-711 series.
______________________________
Alex McEachern
30 September, 2014
Alex@PowerStandards.com
Statement of IEC 61000-4-30 Compliance
K
KALIB
BRERIINGSB
BEVIS
S
utffrdat av riksmtplats 01
CA
ALIBRATION CERTIF
FICATE issued by a Sw
wedish National Labooratory
Contact person
Date
Page
Sttefan Svenssson
2012
2-03-23
1 (2))
Measurement Teechnology
M
+446 10 516 54 155
stefan.svensson@
@sp.se
Referencee
MTeePX22199-K
K06 rev1
Unip
power AB
P. O.. Box 411
SE-4
441 28 Alingss
Swed
den
C
Calibratio
on of Freq
quency
R 1: Summ
Rev
mary includedd, editorial changes
c
I
Identifica
ation
O
Object
Object state
O
C
Calibration
loocation
C
Calibration
d
date
M
Measurem
ment meth
hods and procedurres
The instrumeent was calibbrated by com
T
mparison with
h the electriccal voltage annd frequency
y
s
standards
of SP.
M
Measurem
ment cond
ditions
Room temperature
R
W
Warm-up
tim
me
223.0 2.0 C
C
> 12 h (conneected to main
ns)
R
Results
The result is presented beelow as the error
T
e
expand
ded uncertainnty, or as sett value, meassured
v
value
and exppanded unceertainty. The reported exp
panded uncerrtainty of meeasurement iss stated
a the standarrd uncertaintty of measurrement multip
as
plied by the coverage facctor k = 2, wh
hich for
a normal disttribution corrresponds to a coverage probability off approximattely 95%. Th
he
s
standard
unceertainty has been
b
determined in accorrdance with EA
E Publicatiion EA-4/02. The
l
long
term staability of the calibrated obbject is not in
ncluded in thhe reported eexpanded unccertainty
o measurem
of
ment.
T
Tables
of thee result are foound on folloowing pages..
Office locationn
SP
P
Boox 857
SE
E-501 15 BORS
Sw
weden
Vstersen
Brinellgatan 4
B
SE-504 62 BORS
+46 10 516 50 00
+46 33 13 55 02
info@
@sp.se
KALIBRERIN
NGSBEVIS
CA
ALIBRATION CERTIFICA
ATE
Date
Page
2012
2-03-23
2 (2))
Referencee
MTeePX22199-K
K06 rev1
S
Supply
frequuency
Voltage
(V)
Set Supply
frequency
(Hz)
Readingg EUT
(Hzz)
Expanded
uncertainty
u
(Hz)
42.500
50.000
57.500
42.5001
50.0001
57.5000
0.001
0.001
0.001
63.5
S
Summary:
Inn the tested points
p
the resuults are in co
ompliance with IEC 610000-4-30 Classs A.
T
Traceabil
lity
SP is Nationaal Laboratoryy for electriccal quantitiess and time annd frequency by appointm
S
ment of
t Swedish government.. SP realizes fundamental units such as
the
a volt, ohm and second from
p
primary
standdards. Traceaability for otther units is established
e
fr
from
these realizations by
y means
o in-house calibrations
of
c
a scientificc analyses. To ensure inteernational eqquivalence an
and
nd
a
acceptance
of the establisshed traceabiility, interlab
boratory com
mparisons aree made betweeen
n
national
labooratories.
E
Equipmen
nt
Voltage amplifier Fluke 5215A
V
5
s/n 4555014
F
Frequency
coounter Fluke PM6680B SPno
S
502997
7
D
DAC
Iotech DAC488HR
R/2, SPno 5022132
S
Stefan
Svenssson
__S
Signature_2
KALIBRERINGSBEVIS
utfrdat av riksmtplats 01
CALIBRATION CERTIFICATE issued by a Swedish National Laboratory
Contact person
Date
Page
Stefan Svensson
2012-03-23
1 (3)
Measurement Technology
+46 10 516 54 15
stefan.svensson@sp.se
Reference
MTePX22199-K01 rev1
Unipower AB
P. O. Box 411
SE-441 28 Alingss
Sweden
Identification
Object
Object state
Calibration location
Calibration date
Measurement conditions
Room temperature
Warm-up time
23.0 2.0 C
> 12 h (connected to mains)
Results
The result is presented below as the error expanded uncertainty, or as set value, measured
value and expanded uncertainty. The reported expanded uncertainty of measurement is stated
as the standard uncertainty of measurement multiplied by the coverage factor k = 2, which for
a normal distribution corresponds to a coverage probability of approximately 95%. The
standard uncertainty has been determined in accordance with EA Publication EA-4/02. The
long term stability of the calibrated object is not included in the reported expanded uncertainty
of measurement.
Office location
SP
Box 857
SE-501 15 BORS
Sweden
Vstersen
Brinellgatan 4
SE-504 62 BORS
+46 10 516 50 00
+46 33 13 55 02
info@sp.se
KALIBRERINGSBEVIS
CALIBRATION CERTIFICATE
Date
Page
2012-03-23
2 (3)
Reference
MTePX22199-K01 rev1
Supply voltage
Voltage
(Hz)
50
Set
Supply
Voltage
(V)
Reading
EUT-L1
Reading
EUT-L2
Reading
EUT-L3
Expanded
uncertainty
(V)
(V)
(V)
(V)
95.25
63.5
19.0
6.3
95.278
63.521
19.005
6.304
95.288
63.526
19.009
6.306
95.294
63.528
19.010
6.306
0.020
0.020
0.010
0.006
Summary: In the tested points the results are in compliance with IEC 61000-4-30 Class A.
Unbalance
Nom
Voltage
(V)
Set
Unbalance
(%)
Reading EUT
(%)
Expanded
uncertainty
(%)
63.5
5.05*
4.95**
5.02
4.98
0.01
0.01
Traceability
SP is National Laboratory for electrical quantities and time and frequency by appointment of
the Swedish government. SP realizes fundamental units such as volt, ohm and second from
primary standards. Traceability for other units is established from these realizations by means
of in-house calibrations and scientific analyses. To ensure international equivalence and
acceptance of the established traceability, interlaboratory comparisons are made between
national laboratories.
KALIBRERINGSBEVIS
CALIBRATION CERTIFICATE
Date
Page
2012-03-23
3 (3)
Reference
MTePX22199-K01 rev1
Equipment
Digital wattmeter DSWM, SP, SPno 503 243
Voltage amplifier Fluke 5215A s/n 455014
Frequency counter Fluke PM6680B SPno 502997
DAC Iotech DAC488HR/2, SPno 502132
Reference ZERA COM303-3, s/n 503044
Three phase generator HEG System_4200, s/n 503048
Stefan Svensson
__Signature_2
KALIBRERINGSBEVIS
utfrdat av riksmtplats 01
CALIBRATION CERTIFICATE issued by a Swedish National Laboratory
Contact person
Date
Page
Stefan Svensson
2014-07-01
1 (2)
Measurement Technology
+46 10 516 54 15
stefan.svensson@sp.se
Reference
MTe4P04418-K01
Unipower AB
P. O. Box 411
SE-441 28 Alingss
Sweden
Measurement conditions
Room temperature
23.0 1.0C
Results
The result is presented below as the error expanded uncertainty, or as set value, measured
value and expanded uncertainty. The reported expanded uncertainty of measurement is stated
as the standard uncertainty of measurement multiplied by the coverage factor k = 2, which for
a normal distribution corresponds to a coverage probability of approximately 95%. The
standard uncertainty has been determined in accordance with EA Publication EA-4/02. The
long term stability of the calibrated object is not included in the reported expanded uncertainty
of measurement.
Office location
SP
Box 857
SE-501 15 BORS
Sweden
Vstersen
Brinellgatan 4
SE-504 62 BORS
+46 10 516 50 00
+46 33 13 55 02
info@sp.se
KALIBRERINGSBEVIS
CALIBRATION CERTIFICATE
Date
Page
2014-07-01
2 (2)
Reference
MTe4P04418-K01
Calibration of unbalance
The calibration is an extension of earlier calibration with certificate number MTePX22199K01
Nom
Voltage
(V)
Set
Unbalance
(U2%)
Set
Unbalance
(U0%)
Reading EUT
Reading EUT
(U2%)
(U0%)
Expanded
uncertainty
(%)
60
60
0.01*
2.22**
0,01
2,24
0.06
2.33
0,05
2.34
0.01
0.01
Traceability
SP is National Laboratory for electrical quantities and time and frequency by appointment of
the Swedish government. SP realizes fundamental units such as volt, ohm and second from
primary standards. Traceability for other units is established from these realizations by means
of in-house calibrations and scientific analyses. To ensure international equivalence and
acceptance of the established traceability, interlaboratory comparisons are made between
national laboratories.
Equipment
Three phase comparator Zera Com303-3, SPno 503044
__Signature_1
Stefan Svensson
__Signature_2
KALIBRERINGSBEVIS
utfrdat av riksmtplats 01
CALIBRATION CERTIFICATE issued by a Swedish National Laboratory
Contact person
Date
Page
Stefan Svensson
2012-03-23
1 (2)
Measurement Technology
+46 10 516 54 15
stefan.svensson@sp.se
Reference
MTePX22199-K04 rev1
Unipower AB
P. O. Box 411
SE-441 28 Alingss
Sweden
Calibration of Flicker
Revision 1: summary included.
Identification
Object
Object state
Calibration location
Calibration date
Measurement conditions
Room temperature
Warm-up time
Frequency
23.0 2.0 C
> 12 h (connected to mains)
50.0 0.1 Hz
Results
The result is presented below as the error expanded uncertainty, or as set value, measured
value and expanded uncertainty. The reported expanded uncertainty of measurement is stated
as the standard uncertainty of measurement multiplied by the coverage factor k = 2, which for
a normal distribution corresponds to a coverage probability of approximately 95%. The
standard uncertainty has been determined in accordance with EA Publication EA-4/02. The
long term stability of the calibrated object is not included in the reported expanded uncertainty
of measurement.
The error is calculated as (measured value true value)/true value*100 %.
Tables of the result are found on following pages.
Office location
SP
Box 857
SE-501 15 BORS
Sweden
Vstersen
Brinellgatan 4
SE-504 62 BORS
+46 10 516 50 00
+46 33 13 55 02
info@sp.se
KALIBRERINGSBEVIS
CALIBRATION CERTIFICATE
Date
Page
2012-03-23
2 (2)
Reference
MTePX22199-K04 rev1
Voltage
(V)
Modulation
frequency
(Changes per
minute)
Set Pst
Reading EUT
Expanded
uncertainty
(-)
(-)
(-)
4000
4000
1620
1620
110
7
1
1
1
1.000
10.00
1.000
0.200
1.000
1.000
10.00
1.000
0.200
1.010
9.887
0.992
0.200
1.013
1.027
10.383
1.022
0.200
0.010
0.030
0.010
0.010
0.010
0.010
0.030
0.010
0.010
63.5
Summary: In the tested points the results are in compliance with IEC 61000-4-30 Class A.
Traceability
SP is National Laboratory for electrical quantities and time and frequency by appointment of
the Swedish government. SP realizes fundamental units such as volt, ohm and second from
primary standards. Traceability for other units is established from these realizations by means
of in-house calibrations and scientific analyses. To ensure international equivalence and
acceptance of the established traceability, interlaboratory comparisons are made between
national laboratories.
Equipment
Voltage amplifier Fluke 5215A s/n 455014
DAC Iotech DAC488HR/2, SPno 502132
Software RectangularFlicker ver 1.2
Stefan Svensson
__Signature_2
KALIBRERINGSBEVIS
utfrdat av riksmtplats 01
CALIBRATION CERTIFICATE issued by a Swedish National Laboratory
Contact person
Date
Page
Stefan Svensson
2012-03-23
1 (2)
Measurement Technology
+46 10 516 54 15
stefan.svensson@sp.se
Reference
MTePX22199-K02 rev1
Unipower AB
P. O. Box 411
SE-441 28 Alingss
Sweden
Identification
Object
Object state
Calibration location
Calibration date
Measurement conditions
Room temperature
Warm-up time
Frequency
23.0 2.0 C
> 12 h (connected to mains)
50.0 0.1 Hz
Results
The result is presented below as the error expanded uncertainty, or as set value, measured
value and expanded uncertainty. The reported expanded uncertainty of measurement is stated
as the standard uncertainty of measurement multiplied by the coverage factor k = 2, which for
a normal distribution corresponds to a coverage probability of approximately 95%. The
standard uncertainty has been determined in accordance with EA Publication EA-4/02. The
long term stability of the calibrated object is not included in the reported expanded uncertainty
of measurement.
The error is calculated as (measured value true value)/true value*100 %.
Tables of the result are found on following pages.
Office location
SP
Box 857
SE-501 15 BORS
Sweden
Vstersen
Brinellgatan 4
SE-504 62 BORS
+46 10 516 50 00
+46 33 13 55 02
info@sp.se
KALIBRERINGSBEVIS
CALIBRATION CERTIFICATE
Date
Page
2012-03-23
2 (2)
Reference
MTePX22199-K02 rev1
Voltage
(V)
Set
Dip/Swell
level
(%)
Set
Dip/swell
length
(ms)
Read
Dip/swell
length
(ms)
85
50
115
100
100
100
100
100
120
63.5
Expanded
uncertatinty
(%)
85.01
50.01
115.06
0.01
0.01
0.01
Summary: In the tested points the results are in compliance with IEC 61000-4-30 Class A.
Traceability
SP is National Laboratory for electrical quantities and time and frequency by appointment of
the Swedish government. SP realizes fundamental units such as volt, ohm and second from
primary standards. Traceability for other units is established from these realizations by means
of in-house calibrations and scientific analyses. To ensure international equivalence and
acceptance of the established traceability, interlaboratory comparisons are made between
national laboratories.
Equipment
Digital wattmeter DSWM, SP, SPno 503 243
Voltage amplifier Fluke 5215A s/n 455014
DAC Iotech DAC488HR/2, SPno 502132
Stefan Svensson
__Signature_2
REPORT
Contact person
Date
Bengt Andersson
2014-10-09 4P06655-E1
Reference
Page
1 (3)
Electronics
+46 10 516 56 55
bengt.andersson@sp.se
Unipower AB
Box 411
441 28 Alingss
Commission
Verification of the voltage interruption detection function and interruption time measurement
according to EN 61000-4-30:2009 / IEC 61000-4-30:2008, clause 5.5.2.
Interruption time to be verified:
Interruption level:
Interruption threshold set to:
Interruption hysteresis set to
2000 ms
5% and 15%
10 %
2%
Result summary
The requirements according to EN/IEC 61000-4-30 Class A were fulfilled in the tested points.
Office location
SP
Box 857
SE-501 15 BORS
Sweden
Vstersen
Brinellgatan 4
SE-504 62 BORS
+46 10 516 50 00
+46 33 13 55 02
info@sp.se
This document may not be reproduced other than in full, except with the
prior written approval of SP.
REPORT
Date
2014-10-07
Date
Reference
2014-10-09 4P06655-E1
Temperature
23 C 3 C
Page
2 (3)
Humidity
31 % 5 %
Measurement equipment
Variable voltage supply HP 6813B
Voltage interruption generator T 3000
Multimeter Fluke 83
Variable transformer
Temperature and humidity meter Testo 615
503 091
901 284
503 418
503 518
503 418
REPORT
Date
Reference
2014-10-09 4P06655-E1
Page
3 (3)
Result
Voltage dip level Voltage dip time
9.75 V (15 %)
2 000 ms
3.25 V (5 %)
2 000 ms
Result
Not detected as voltage interruption (> 10 %)
Detected interruption.
Registered interruption time 2.010s
Examined by
__Signature_1
__Signature_2
Bengt Andersson
Tomas Bodeklint
KALIBRERINGSBEVIS
utfrdat av riksmtplats 01
CALIBRATION CERTIFICATE issued by a Swedish National Laboratory
Contact person
Date
Page
Stefan Svensson
2012-03-23
1 (6)
Measurement Technology
+46 10 516 54 15
stefan.svensson@sp.se
Reference
MTePX22199-K03 rev2
Unipower AB
P. O. Box 411
SE-441 28 Alingss
Sweden
Calibration of Harmonics
Rev1: Editorial changes, summary included, rev2: editorial.
Identification
Object
Object state
Calibration location
Calibration date
Measurement conditions
Room temperature
Warm-up time
23.0 2.0 C
> 12 h (connected to mains)
Results
The result is presented below as the error expanded uncertainty, or as set value,
measured value and expanded uncertainty. The reported expanded uncertainty of
measurement is stated as the standard uncertainty of measurement multiplied by the
coverage factor k = 2, which for a normal distribution corresponds to a coverage
probability of approximately 95%. The standard uncertainty has been determined in
accordance with EA Publication EA-4/02. The long term stability of the calibrated object
is not included in the reported expanded uncertainty of measurement.
The error is calculated as (measured value true value) or for percentage values
(measured percentage value true percentage value).
Tables of the result are found on following pages.
Office location
SP
Box 857
SE-501 15 BORS
Sweden
Vstersen
Brinellgatan 4
SE-504 62 BORS
+46 10 516 50 00
+46 33 13 55 02
info@sp.se
KALIBRERINGSBEVIS
CALIBRATION CERTIFICATE
Date
Page
2012-03-23
2 (6)
Reference
MTePX22199-K03 rev2
L1
Error
L2
Error
L3
Error
Expanded
uncertainty
/Harm. nbr
/V
/mV
/mV
/mV
/mV
60
-16
-4
-4
/Harm. nbr
/%
/%
/%
/%
/%
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
23
33
38
6.00
12.00
3.00
16.00
2.00
14.00
2.00
5.00
2.00
10.00
2.00
9.00
2.00
4.00
2.00
8.00
2.00
7.00
2.00
5.60
2.00
2.00
0.00
0.01
0.01
0.04
0.01
0.05
0.01
0.02
0.01
0.05
0.01
0.04
0.01
0.02
0.01
0.04
0.01
0.03
0.01
0.02
0.00
0.00
0.01
0.03
0.01
0.08
0.01
0.09
0.01
0.04
0.02
0.09
0.02
0.09
0.02
0.04
0.02
0.07
0.02
0.06
0.01
0.04
0.00
0.00
0.01
0.03
0.01
0.08
0.01
0.09
0.01
0.04
0.02
0.09
0.02
0.09
0.02
0.04
0.02
0.08
0.02
0.07
0.01
0.05
0.01
0.01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
KALIBRERINGSBEVIS
CALIBRATION CERTIFICATE
Date
Page
2012-03-23
3 (6)
Reference
MTePX22199-K03 rev2
L1
Error
L2
Error
L3
Error
Expanded
uncertainty
/Harm. nbr
/V
/mV
/mV
/mV
/mV
60
-19
-2
-2
/Harm. nbr
/%
/%
/%
/%
/%
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
23
33
38
3.00
6.00
1.50
8.00
1.00
7.00
1.00
2.50
1.00
5.00
1.00
4.50
1.00
2.00
1.00
4.00
1.00
3.50
1.00
2.80
1.00
1.00
0.00
0.01
0.01
0.04
0.01
0.05
0.01
0.02
0.01
0.05
0.01
0.04
0.01
0.02
0.01
0.04
0.01
0.03
0.01
0.02
0.00
0.00
0.00
0.01
0.01
0.04
0.01
0.05
0.01
0.02
0.01
0.05
0.01
0.04
0.01
0.02
0.01
0.04
0.01
0.03
0.01
0.02
0.00
0.00
0.00
0.01
0.01
0.04
0.01
0.05
0.01
0.02
0.01
0.05
0.01
0.04
0.01
0.02
0.01
0.04
0.01
0.03
0.01
0.02
0.00
0.00
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
KALIBRERINGSBEVIS
CALIBRATION CERTIFICATE
Date
Page
2012-03-23
4 (6)
Reference
MTePX22199-K03 rev2
Set voltage
L1
Error
L2
Error
L3
Error
Expanded
uncertainty
/Harm. nbr
/V
/mV
/mV
/mV
/mV
60
-15
-15
/Harm. nbr
/%
/%
/%
/%
/%
3
4
7
9
11
16
23
2.40
0.60
2.80
1.00
2.00
0.40
1.12
0.01
0.00
0.02
0.01
0.02
0.00
0.01
0.01
0.00
0.02
0.01
0.02
0.00
0.01
0.01
0.00
0.02
0.01
0.02
0.00
0.01
0,01
0,01
0,01
0,01
0,01
0,01
0,01
KALIBRERINGSBEVIS
CALIBRATION CERTIFICATE
Date
Page
2012-03-23
5 (6)
Reference
MTePX22199-K03 rev2
Set voltage
L1
Error
L2
Error
L3
Error
Expanded
uncertainty
/Harm. nbr
/V
/mV
/mV
/mV
/mV
60
-15
-3
-3
/Harm. nbr
/%
/%
/%
/%
/%
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
23
33
38
0.30
0.60
0.15
0.80
0.10
0.70
0.10
0.25
0.10
0.50
0.10
0.45
0.10
0.20
0.10
0.40
0.10
0.35
0.10
0.28
0.10
0.10
-0.002
0.000
0.001
0.004
0.001
0.006
0.001
0.003
0.001
0.007
0.001
0.005
0.000
0.002
0.001
0.004
0.001
0.002
0.001
0.004
0.001
0.001
-0.001
0.001
0.001
0.004
0.001
0.006
0.001
0.003
0.001
0.007
0.001
0.005
0.001
0.002
0.001
0.004
0.001
0.003
0.001
0.004
0.001
0.001
-0.001
0.001
0.001
0.005
0.001
0.006
0.000
0.003
0.001
0.007
0.000
0.005
0.001
0.002
0.002
0.004
0.001
0.002
0.001
0.004
0.001
0.000
0,005
0,005
0,005
0,005
0,005
0,005
0,005
0,005
0,005
0,005
0,005
0,005
0,005
0,005
0,005
0,005
0,005
0,005
0,005
0,005
0,005
0,005
Summary: In all the above tested points the results are in compliance with IEC 61000-430 Class A.
KALIBRERINGSBEVIS
CALIBRATION CERTIFICATE
Date
Page
2012-03-23
6 (6)
Reference
MTePX22199-K03 rev2
Traceability
SP is National Laboratory for electrical quantities and time and frequency by appointment of the Swedish government. SP realizes fundamental units such as volt, ohm and
second from primary standards. Traceability for other units is established from these
realizations by means of in-house calibrations and scientific analyses. To ensure international equivalence and acceptance of the established traceability, interlaboratory
comparisons are made between national laboratories.
Equipment
Digital wattmeter DSWM, SP, SPno 503 243
Voltage amplifier Fluke 5215A s/n 455014
DAC Iotech DAC488HR/2, SPno 502132
Stefan Svensson
__Signature_2
KALIBRERINGSBEVIS
utfrdat av riksmtplats 01
CALIBRATION CERTIFICATE issued by a Swedish National Laboratory
Contact person
Date
Page
Stefan Svensson
2014-07-01
1 (3)
Measurement Technology
+46 10 516 54 15
stefan.svensson@sp.se
Reference
MTe4P04418-K03
Unipower AB
P. O. Box 411
SE-441 28 Alingss
Sweden
Calibration of Harmonics
Identification
Object
Object state
Calibration location
Calibration date
Measurement conditions
Room temperature
23.0 1.0C
Results
The result is presented below as the error expanded uncertainty, or as set value, measured
value and expanded uncertainty. The reported expanded uncertainty of measurement is stated
as the standard uncertainty of measurement multiplied by the coverage factor k = 2, which for
a normal distribution corresponds to a coverage probability of approximately 95%. The
standard uncertainty has been determined in accordance with EA Publication EA-4/02. The
long term stability of the calibrated object is not included in the reported expanded uncertainty
of measurement.
The error is calculated as (measured value true value)
Tables of the result are found on following pages.
Office location
SP
Box 857
SE-501 15 BORS
Sweden
Vstersen
Brinellgatan 4
SE-504 62 BORS
+46 10 516 50 00
+46 33 13 55 02
info@sp.se
KALIBRERINGSBEVIS
CALIBRATION CERTIFICATE
Date
Page
2014-07-01
2 (3)
Reference
MTe4P04418-K03
/Harm. nbr
41
45
50
/V
0.08
0.06
0.06
Error
Error
Error
0.000
0.000
0.000
0.000
0.000
-0.001
0.001
0.000
0.000
/V
/V
/V
Expanded
uncertainty
/mV
0.006
0.006
0.006
Set voltage
/Harm. nbr
41
45
50
/V
0.33
0.24
0.24
Error
Error
Error
0.000
-0.001
-0.002
0.001
0.000
-0.004
0.001
0.000
-0.001
/V
/V
/V
Expanded
uncertainty
/mV
0.006
0.006
0.006
Set voltage
/Harm. nbr
41
45
50
/V
0.8
0.6
0.6
Error
Error
Error
-0.0003
-0.0017
-0.0040
0.0010
-0.0014
-0.0098
0.0013
-0.0006
-0.0011
/V
/V
/V
Expanded
uncertainty
/mV
0.006
0.006
0.006
KALIBRERINGSBEVIS
CALIBRATION CERTIFICATE
Date
Page
2014-07-01
3 (3)
Reference
MTe4P04418-K03
Set voltage
/Harm. nbr
41
45
50
/V
1.6
1.2
1.2
Error
Error
Error
-0.001
-0.003
-0.007
0.001
-0.004
-0.020
0.002
-0.001
-0.001
/V
/V
/V
Expanded
uncertainty
/mV
0.006
0.006
0.006
Summary: In the tested points the results are in compliance with IEC 61000-4-30 Class A.
Traceability
SP is National Laboratory for electrical quantities and time and frequency by appointment of
the Swedish government. SP realizes fundamental units such as volt, ohm and second from
primary standards. Traceability for other units is established from these realizations by means
of in-house calibrations and scientific analyses. To ensure international equivalence and
acceptance of the established traceability, interlaboratory comparisons are made between
national laboratories.
Equipment
Digital wattmeter DSWM, SP, SPno 503 243
DAC Iotech DAC488HR/2, SPno 502132
Voltage amplifier Fluke 5215A s/n 455014
__Signature_1
Stefan Svensson
__Signature_2
KALIBRERINGSBEVIS
utfrdat av riksmtplats 01
CALIBRATION CERTIFICATE issued by a Swedish National Laboratory
Contact person
Date
Page
Stefan Svensson
2012-03-23
1 (3)
Measurement Technology
+46 10 516 54 15
stefan.svensson@sp.se
Reference
MTePX22199-K05 rev2
Unipower AB
P. O. Box 411
SE-441 28 Alingss
Sweden
Identification
Object
Object state
Calibration location
Calibration date
Measurement conditions
Room temperature
Warm-up time
23.0 2.0 C
> 12 h (connected to mains)
Results
The result is presented below as the error expanded uncertainty, or as set value, measured
value and expanded uncertainty. The reported expanded uncertainty of measurement is stated
as the standard uncertainty of measurement multiplied by the coverage factor k = 2, which for
a normal distribution corresponds to a coverage probability of approximately 95%. The
standard uncertainty has been determined in accordance with EA Publication EA-4/02. The
long term stability of the calibrated object is not included in the reported expanded uncertainty
of measurement.
The error is calculated as (measured value true value)/true value*100 %.
Tables of the result are found on following pages.
Office location
SP
Box 857
SE-501 15 BORS
Sweden
Vstersen
Brinellgatan 4
SE-504 62 BORS
+46 10 516 50 00
+46 33 13 55 02
info@sp.se
KALIBRERINGSBEVIS
CALIBRATION CERTIFICATE
Date
Page
2012-03-23
2 (3)
Reference
MTePX22199-K05 rev2
Signalling, at 60 V
Signal
frequency
(Hz)
Set signal
level
(V)
Reading EUT
(V)
Expanded
uncertainty
(V)
620
1070
1070
3
6
9
3.020
5.857
9.042
0.001
0.001
0.001
Summary: In the tested points the results are in compliance with IEC 61000-4-30 Class A.
Interharmonics, at 60 V
Signal
frequency
(Hz)
Set singal
level
(V)
Reading
EUT U1
(V)
Reading
EUT U2
(V)
Reading
EUT U3
(V)
Expanded
uncertainty
(V)
83.33
175
375
3
1.8
1.2
2.986
1.802
1.204
2.945
1.802
1.205
2.945
1.802
1.205
0.001
0.001
0.001
Summary: In the tested points the results are in compliance with IEC 61000-4-30 Class A.
Traceability
SP is National Laboratory for electrical quantities and time and frequency by appointment of
the Swedish government. SP realizes fundamental units such as volt, ohm and second from
primary standards. Traceability for other units is established from these realizations by means
of in-house calibrations and scientific analyses. To ensure international equivalence and
acceptance of the established traceability, interlaboratory comparisons are made between
national laboratories.
KALIBRERINGSBEVIS
CALIBRATION CERTIFICATE
Date
Page
2012-03-23
3 (3)
Reference
MTePX22199-K05 rev2
Equipment
Digital wattmeter DSWM, SP, SPno 503 243
Voltage amplifier Fluke 5215A s/n 455014
DAC Iotech DAC488HR/2, SPno 502132
Stefan Svensson
__Signature_2
KALIBRERINGSBEVIS
utfrdat av riksmtplats 01
CALIBRATION CERTIFICATE issued by a Swedish National Laboratory
Contact person
Date
Page
Stefan Svensson
2014-07-01
1 (3)
Measurement Technology
+46 10 516 54 15
stefan.svensson@sp.se
Reference
MTePX04418-K05
Unipower AB
P. O. Box 411
SE-441 28 Alingss
Sweden
Measurement conditions
Room temperature
23.0 2.0 C
Results
The result is presented below as the error expanded uncertainty, or as set value, measured
value and expanded uncertainty. The reported expanded uncertainty of measurement is stated
as the standard uncertainty of measurement multiplied by the coverage factor k = 2, which for
a normal distribution corresponds to a coverage probability of approximately 95%. The
standard uncertainty has been determined in accordance with EA Publication EA-4/02. The
long term stability of the calibrated object is not included in the reported expanded uncertainty
of measurement.
The error is calculated as (measured value true value)/true value*100 %.
Tables of the result are found on following pages.
Office location
SP
Box 857
SE-501 15 BORS
Sweden
Vstersen
Brinellgatan 4
SE-504 62 BORS
+46 10 516 50 00
+46 33 13 55 02
info@sp.se
KALIBRERINGSBEVIS
CALIBRATION CERTIFICATE
Date
Page
2014-07-01
2 (3)
Reference
MTePX04418-K05
Signalling, at 60 V
Signal
frequency
(Hz)
Set signal
level
(%)
Reading EUT
(%)
Expanded
uncertainty
(%)
315
315
15
5
15.049
5.022
0.001
0.001
For sinusoidal signals the reported levels S1-S25 (0 -2500 Hz) were all < 0,095 %
Summary: In the tested points the results are in compliance with IEC 61000-4-30 Class A.
Interharmonics, at 60 V
Signal
frequency
(Hz)
Set singal
level
(V)
Reading
EUT U1
(V)
Reading
EUT U2
(V)
Reading
EUT U3
(V)
Expanded
uncertainty
(V)
25
225
1075
1725
2475
3.6
3.6
3.6
3.6
3.6
3.580
3.601
3.611
3.576
3.475
3.586
3.607
3.618
3.583
3.444
3.582
3.603
3.613
3.579
3.491
0.001
0.001
0.001
0.001
0.001
For sinusoidal 60V signals the reported levels were all < 0,03 V
Summary: In the tested points the results are in compliance with IEC 61000-4-30 Class A.
Traceability
SP is National Laboratory for electrical quantities and time and frequency by appointment of
the Swedish government. SP realizes fundamental units such as volt, ohm and second from
primary standards. Traceability for other units is established from these realizations by means
of in-house calibrations and scientific analyses. To ensure international equivalence and
acceptance of the established traceability, interlaboratory comparisons are made between
national laboratories.
KALIBRERINGSBEVIS
CALIBRATION CERTIFICATE
Date
Page
2014-07-01
3 (3)
Reference
MTePX04418-K05
Equipment
Digital wattmeter DSWM, SP, SPno 503 243
Voltage amplifier Fluke 5215A s/n 455014
DAC Iotech DAC488HR/2, SPno 502132
__Signature_1
Stefan Svensson
__Signature_2
KALIBRERINGSBEVIS
utfrdat av riksmtplats 01
CALIBRATION CERTIFICATE issued by a Swedish National Laboratory
Contact person
Date
Page
Stefan Svensson
2014-08-28
1 (6)
Measurement Technology
+46 10 516 54 15
stefan.svensson@sp.se
Reference
MTeP05735-K01 Rev1
Unipower AB
P. O. Box 411
SE-441 28 Alingss
Sweden
Calibration of Power
Rev1:Editorial
Identification
Object
Object state
Calibration location
Calibration date
Measurement conditions
Room temperature
23.0 1.0C
Results
The result is presented below as the error expanded uncertainty, or as set value, measured
value and expanded uncertainty. The reported expanded uncertainty of measurement is stated
as the standard uncertainty of measurement multiplied by the coverage factor k = 2, which for
a normal distribution corresponds to a coverage probability of approximately 95%. The
standard uncertainty has been determined in accordance with EA Publication EA-4/02. The
long term stability of the calibrated object is not included in the reported expanded uncertainty
of measurement.
The error is calculated as (measured value true value)/true value*100 %.
Tables of the result are found on following pages.
Office location
SP
Box 857
SE-501 15 BORS
Sweden
Vstersen
Brinellgatan 4
SE-504 62 BORS
+46 10 516 50 00
+46 33 13 55 02
info@sp.se
KALIBRERINGSBEVIS
CALIBRATION CERTIFICATE
Date
Page
2014-08-28
2 (6)
Reference
MTeP05735-K01 Rev1
Set
Set
Current power
factor
(A)
(-)
Error
Ptot
Error
Qtot
Error
PF
(%)
(%)
(-)
5
5
5
1
0.5i
0.8c
-0.022
-0.168
0.038
0.025
0.140
0.0000
-0.0007
0.0004
0,020
0,020
0,020
0,020
0,020
0,001
0,001
0,001
1.2
1.2
1.2
1
0.5i
0.8c
-0.054
-0.066
-0.012
-0.014
-0.115
0.0000
-0.0002
0.0003
0,020
0,020
0,020
0,020
0,020
0,001
0,001
0,001
1.0
1.0
1.0
1
0.5i
0.8c
-0.038
-0.116
-0.006
-0.010
-0.049
0.0000
-0.0004
0.0001
0,020
0,020
0,020
0,020
0,020
0,001
0,001
0,001
0.5
0.5
0.5
1
0.5i
0.8c
-0.042
-0.086
-0.027
-0.016
0.083
0.000
0.000
0.000
0,020
0,020
0,020
0,020
0,020
0,001
0,001
0,001
0.1
0.1
0.1
1
0.5i
0.8c
-0.032
-0.096
-0.027
0.067
-0.053
-0.0010
-0.0009
-0.0006
0,020
0,020
0,020
0,020
0,020
0,001
0,001
0,001
0.05
0.05
1
0.5i
0.095
0.090
0.150
-0.001
-0.001
0,020
0,020
0,020
0,001
0,001
0.02
0.02
0.5i
0.8c
-0.040
0.075
0.431
-0.002
-0.0060
-0.0070
0,020
0,020
0,020
0,020
0,001
0,001
0,01
-0.0339
0,020
0,001
-0.065
Summary: In the tested points the results are in compliance with IEC 62053-22, cl 0,2 S.
KALIBRERINGSBEVIS
CALIBRATION CERTIFICATE
Date
Page
2014-08-28
3 (6)
Reference
MTeP05735-K01 Rev1
Set
Set
Current power
factor
(A)
(-)
Error
Ptot
Error
Qtot
Error
PF
(%)
(%)
(-)
5
5
5
1
0.5i
0.8c
-0.073
-0.223
-0.012
-0.024
-0.184
0.0000
0.0008
-0.0005
0,020
0,020
0,020
0,020
0,020
0,0010
0,0010
0,0010
1.2
1.2
1.2
1
0.5i
0.8c
-0.054
-0.145
-0.021
-0.027
-0.120
0.0000
0.0004
-0.0003
0,020
0,020
0,020
0,020
0,020
0,0010
0,0010
0,0010
1.0
1.0
1.0
1
0.5i
0.8c
0.023
-0.051
0.092
0.026
-0.034
0.0000
0.0001
-0.0003
0,020
0,020
0,020
0,020
0,020
0,0010
0,0010
0,0010
0.5
0.5
0.5
1
0.5i
0.8c
-0.039
-0.104
-0.020
-0.030
-0.078
0.0000
0.0000
-0.0001
0,020
0,020
0,020
0,020
0,020
0,0010
0,0010
0,0010
0.1
0.1
0.1
1
0.5i
0.8c
-0.051
-0.119
-0.043
0.013
0.044
0.0011
0.0008
0.0010
0,020
0,020
0,020
0,020
0,020
0,0010
0,0010
0,0010
0.05
-0.093
0.0023
0,020
0,0010
0.02
0.02
0.5i
0.8c
-0.188
-0.017
0.085
0.493
0.0052
0.0089
0,020
0,020
0,020
0,020
0,0010
0,0010
0.01
-0.178
0.0333
0,020
0,0010
Summary: In the tested points the results are in compliance with IEC 62053-22, cl 0,2 S.
KALIBRERINGSBEVIS
CALIBRATION CERTIFICATE
Date
Page
2014-08-28
4 (6)
Reference
MTeP05735-K01 Rev1
Set
Set
Current power
factor
(A)
(-)
Phase
Error
Ptot
Error
Qtot
Error
PF
(-)
(%)
(%)
(-)
1.2
1.2
1.2
1.2
1.2
1.2
1
1
1
0.5 ind
0.5 ind
0.5 ind
L1
L2
L3
L1
L2
L3
-0.050
-0.041
-0.107
-0.038
-0.012
-0.378
-0.051
-0.039
0.006
-0.0037
-0.0055
-0.0042
-0.0049
-0.0026
-0.0034
0,020
0,020
0,020
0,020
0,020
0,020
0,020
0,020
0,020
0,0010
0,0010
0,0010
0,0010
0,0010
0,0010
1
1
1
1
1
1
1
1
1
0.5 ind
0.5 ind
0.5 ind
L1
L2
L3
L1
L2
L3
-0.030
-0.023
-0.082
-0.028
-0.047
-0.347
-0.021
-0.024
0.023
-0.0043
-0.0065
-0.0052
-0.0022
-0.0031
-0.0038
0,020
0,020
0,020
0,020
0,020
0,020
0,020
0,020
0,020
0,0010
0,0010
0,0010
0,0010
0,0010
0,0010
0.1
0.1
0.1
0.5 ind
0.5 ind
0.5 ind
L1
L2
L3
0.145
0.168
-0.226
0.120
0.124
0.166
-0.0182
-0.0267
-0.0254
0,020
0,020
0,020
0,020
0,020
0,020
0,0010
0,0010
0,0010
0.05
0.05
0.05
1
1
1
L1
L2
L3
0.094
0.093
0.027
-0.0703
-0.1031
-0.0975
0,020
0,020
0,020
0,0010
0,0010
0,0010
Summary: In the tested points the results are in compliance with IEC 62053-22, cl 0,2 S.
KALIBRERINGSBEVIS
CALIBRATION CERTIFICATE
Date
Page
2014-08-28
5 (6)
Reference
MTeP05735-K01 Rev1
Set
Set
Current power
factor
(A)
(-)
Phase
Error
Ptot
Error
Qtot
Error
PF
(-)
(%)
(%)
(-)
1.2
1.2
1.2
1.2
1.2
1.2
1
1
1
0.5 ind
0.5 ind
0.5 ind
L1
L2
L3
L1
L2
L3
-0.048
-0.039
-0.100
-0.050
-0.011
-0.396
-0.055
-0.062
-0.008
0.0043
0.0052
0.0041
0.0020
0.0023
0.0035
0,020
0,020
0,020
0,020
0,020
0,020
0,020
0,020
0,020
0,0010
0,0010
0,0010
0,0010
0,0010
0,0010
1
1
1
1
1
1
1
1
1
0.5 ind
0.5 ind
0.5 ind
L1
L2
L3
L1
L2
L3
-0.049
-0.039
-0.083
-0.041
-0.005
-0.357
-0.057
-0.055
-0.010
0.0050
0.0062
0.0051
0.0023
0.0029
0.0039
0,020
0,020
0,020
0,020
0,020
0,020
0,020
0,020
0,020
0,0010
0,0010
0,0010
0,0010
0,0010
0,0010
0.1
0.1
0.1
0.5 ind
0.5 ind
0.5 ind
L1
L2
L3
0.044
0.088
-0.272
-0.072
-0.094
-0.041
0.0191
0.0252
0.0263
0,020
0,020
0,020
0,020
0,020
0,020
0,0010
0,0010
0,0010
0.05
0.05
0.05
1
1
1
L1
L2
L3
-0.026
0.009
-0.062
0.0786
0.0990
0.0944
0,020
0,020
0,020
0,0010
0,0010
0,0010
Summary: In the tested points the results are in compliance with IEC 62053-22, cl 0,2 S.
KALIBRERINGSBEVIS
CALIBRATION CERTIFICATE
Date
Page
2014-08-28
6 (6)
Reference
MTeP05735-K01 Rev1
Traceability
SP is National Laboratory for electrical quantities and time and frequency by appointment of
the Swedish government. SP realizes fundamental units such as volt, ohm and second from
primary standards. Traceability for other units is established from these realizations by means
of in-house calibrations and scientific analyses. To ensure international equivalence and
acceptance of the established traceability, interlaboratory comparisons are made between
national laboratories.
Equipment
Three phase comparator Zera Com303-3, SPno 503044
__Signature_1
Stefan Svensson
__Signature_2