K3HB - S
Visual clarity and instantaneous measurement.
Control status and judgement results can be ascertained
at a glance using the display color and position meter.
Features
Intelligent
Clear
Peak value
100
96
Timing of
internal
sampling
Time
Timing of
internal
sampling
0
Time
Position meter
Peak hold
Sampling hold
Reference level
Workpiece
Bottom hold
Time (t)
Timing signal
input
ON
OFF
27%
shorter
than earlier
models
Depth: 95 mm
Base Units
K3HB-S@
K3HB-S@-@@@
Optional Board
Sensor Power Supply/Output Boards
K33-@
2
Relay/Transistor Output Boards
2 3 4
K34-@
3
Event Input Boards
K35-@
4
K3HB-S
Ordering Information
DC Voltage/Current Input (for All Models)
(Each model has a multirange, thus corresponding to the following voltage and current ranges.)
Current measurement range
0.000 to 20.000 mA or
4.000 to 20.000 mA
Base Units
Model
Supply voltage
Part number
K3HB-SSD
100-240VAC
24 VAC/VDC
K3HB-SSD
24VAC/VDC
Applicable sensor
power supply/
output boards
K33-CPA
K33-A
Applicable relay/
transistor output
boards
K34-C1
K34-C2
K34-T1
K34-T2
Applicable event
input boards
K35-1
K35-2
K35-3
K35-4
Specifications
Ratings
Power supply voltage
Power consumption
(with maximum load)
(See note.)
18 VA max.
Input signals
Measurement method
Event input
NPN open collector or no-voltage contact signal (Refer to Event Input Ratings on page 7 for details.)
PNP open collector
Timing input
Startup
compensation
timer input
24 VAC: 11 VA max.
24 VDC: 7 W max.
Hold input
Reset input
Forced-zero input
Bank input
Output
(Depends on
model.)
Relay contact
output
Transistor output
HH/H/PASS/L/LL (NPN open collector; Maximum load voltage: 24 VDC; Maximum load current: 50 mA;
Leakage current: 100 A max.)
HH/H/PASS/L/LL (PNP open collector; Maximum load voltage: 24 VDC; Maximum load current: 50 mA;
Leakage current: 100 A max.)
Display method
Main functions
Scaling function, 2-input calculation function, measurement operation selection, averaging, high pass
filter, forced-zero, zero-limit, output hysteresis, output OFF delay, output test, teaching, display value
selection, display color selection, key protection, bank selection, display refresh period, maximum/
minimum hold, reset
25% to 85%
Storage temperature
Altitude
2,000 m max.
Accessories
Note: A control power supply capacity greater than the rated value is required when power is turned ON. Particular attention is required when using
two or more DC power supply models. When power is turned ON or when the startup compensation timer operates, all outputs will turn OFF
if the Unit is not performing measurement.
K3HB-S
Characteristics
Sampling period
1 input
2 inputs
Insulation resistance
Dielectric strength
Noise immunity
100 to 240-VAC models: 1,500 V at power supply terminals in normal or common mode (waveform with
1-ns rising edge and pulse width of 1 s/100 ns)
24-VAC/VDC models: 1,500 V at power supply terminals in normal or common mode (waveform with 1ns rising edge and pulse width of 1 s/100 ns)
Vibration resistance
Shock resistance
Weight
Enclosure ratings
Memory protection
Installation environment
Safety standards
EMC
Input type
Measurement
range
Indication range
Accuracy
(at 235C)
0 to 5 V
1 to 5 V
1.000 to 5.000 V
0.500 to 5.500 V
5 V
5.000 V
5.000 V
10 V
10.000 V
11.000 V
DC current/voltage 0 to 20 mA
input
4 to 20 mA
Input impedance
Maximum
absolute rated
input
120 max.
31 mA
1 M min.
10 V
14.5 V
TIMING
Contact input
ON: 1 k max.
OFF: 100 k min.
---
No-contact input
Output Ratings
Contact Output
Item
Inductive loads
(250 VAC, cos=0.4;
30 VDC, L/R=7 ms)
Resistive loads
(250 VAC, cos=1;
30 VDC, L/R=0 ms)
Rated load
250 VAC, 5 A
30 VDC, 5 A
250 VAC, 1 A
30 VDC, 1 A
Rated through
current
5A
Mechanical life
expectancy
5,000,000 operations
Transistor Output
Maximum load voltage
24 VDC
50 mA
Leakage current
100 A max.
K3HB-S
Connections
Terminal Arrangement
A
1
2
3
E Analog Input
4
5
6
Connection terminals
Input ranges
1 input (1NA)
E1 Input B
Current
input
E2 Input A
E2 E3 (INA)
0.000 to 20.000mA
E2 E3
E3 COM
E1 E3 (INB)
4.000 to 20.000mA
Voltage
input
E4 Input A
0.000 to 5.000V
E5 Input B
1.000 to 5.000V
2 inputs
NC E6
5.000V
E4 E3 (INA)
E4 E3
E5 E3 (INB)
10.000V
A1
A2
A2
D Event Input
D1 TIMING
D2 S-TMR
D3 HOLD
Applicable connector:
XG4M-1030 (OMRON)
D4 RESET
12-VDC, 80-mA
models with PASS output
(K33-CPA)
PASS
D5 ZERO
12-VDC, 80-mA
models
(K33-A)
B1
TIMING 1
HOLD
ZERO
BANK4
BANK1 9
D6 COM
B1
B2
B2
NC
B3
B3
NC B4
+
B4
B5 Sensor power
B5 Sensor power
supply
B6 12 VDC
80 mA
supply
B6 12 VDC
80 mA
C Relay/Transistor Outputs
H/L models
with relay outputs
(K34-C1)
HH/H/PASS/L/LL models
with PNP transistor outputs
(K34-T2)
HH
C1
HH
C1
HH
C1
C2
C2
C2
C2
COM C3
PASS C3
PASS C3
C4
C4
C4
C4
C5
LL
C5
LL
C5
LL
C5
C6
HH/H/PASS/L/LL models
with NPN transistor outputs
(K34-T1)
C1
C3
HH/H/L/LL models
with relay outputs
(K34-C2)
COM C6
COM C6
COM C6
2 : S-TMR
4 : RESET
6 : COM
8 : BANK2
10 10 : COM
Output Circuits
Internal Block Diagram
indicates
electrically isolated
regions.
Key Display
Input
circuit
AD
converter
Drive
circuit
EEPROM
Event
input
circuit
Waveshaping
circuit
Transistor output
Drive
circuit
Microcomputer
Contact output
Drive
circuit
Filter
Power supply
E4, E5
Voltage input
AD
E1, E2
Current input
110 (TYP)
B
COM E3
AD
COM E3
A+B=1 M
Event Inputs
Use terminal D6 as the common terminal.
Use open collector or no-voltage contacts for event input.
Note: PNP types are also available.
12 V
S-TMR : D2
HOLD : D3
RESET : D4
ZERO : D5
4.7 K
12 V
TIMING
560
D1
3.9 K
D6
COM
750
D6
COM
K3HB-S
Comparative Outputs
Contact Outputs
5V
C6
Operation
Operations in RUN Level
Setting Forced-zero
When the measurement value is displayed, the maximum and minimum values can be displayed by pressing the MAX/MIN Key.
Measurement
value
MAX/MIN Key
Maximum
value
MAX/MIN Key
Minimum
value
Measurement/
MAX/MIN value
Comparative
set value LL
10
Measurement
value
Measurement value
after forced-zero set
Forced-zero input
Measurement/
MAX/MIN value
Comparative
set value H
Display value
MAX/MIN Key
Measurement/
MAX/MIN value
Comparative
set value HH
ZERO LED
Not lit
Lit
Releasing Forced-zero
Forced-zero can be released by holding down the UP Key for 1 s
min. The zero status indicator will turn OFF.
Power ON
Power ON
Adjustment
Less than
1s
3 s min.
Protect
RUN
Measurement starts.
3 s min.
1 s min.
Measurement stops.
Input
adjustment
Less than 1 s
Display
adjustment
Less than 1 s
Initialization
Less than 1 s
Less than 1 s
Output test
1 s min.
Less than 1 s
Comparative
set value
1 s min.
Password
Advanced-function
setting
LEVEL transition
Protect Level
Move to the input setting level, and perform
similar settings in the display adjustment level
and the comparative set value level.
Operation
Press the LEVEL and MODE Keys Simultaneously in RUN level for at least 1
second. The PV display will start to flash. Press the same keys for at least 2
seconds to move to protect level.
Press the LEVEL and MODE Keys simultaneously for at least 1 second to
return to RUN level.
Adjustment Level
Press the LEVEL Key in RUN level once (less than 1 second). The level will
change to adjustment level when the key is released.
Use the same operation to return from adjustment level to RUN level.
K3HB-S
11
0
LEVEL
A: 0 / B :1 / K-A: 2 / A+B: 3
A-B: 4 / K-(A+B): 5 / B/AX
10000: 6 /(B/A-1)X10000: 7
Calculation
cal
Input type A
in-ta
No operation for 5 s
0-20 /4-20 /
0-5 /1-5 5 /10 /
4-20
No operation for 5 s
Scaling
input value A1
Power ON
inp.a1
99999
4.000
No operation for 5 s
dsp.a1
Scaling
display value A1
LEVEL
3 s min.
RUN level
Scaling
input value A2
99999
4000
No operation for 5 s
inp.a2
99999
20.000
No operation for 5 s
Measurement stops.
Measurement value
Comparative
set value HH
99999
dsp.a2
Scaling
display value A2
99999
No operation for 5 s
Measurement value
Comparative
set value H
99999
99999
Measurement value
Comparative
set value L
-19999
in-tb
Scaling
input value B1
inp.b1
No operation for 5 s
0-20 /4-20 /
0-5 /1-5 5 /10 /
4-20
No operation for 5 s
99999
LEVEL
1 s min.
No operation for 5 s
Measurement value
Comparative
-19999
set value LL
Input type B
Measurement starts.
No operation for 5 s
99999
20000
99999
4.000
No operation for 5 s
dsp.b1
Scaling
display value B1
99999
99999
4000
No operation for 5 s
No operation for 5 s
Scaling
input value B2
Bank
99999
20.000
No operation for 5 s
dsp.b2
Scaling
display value B2
LEVEL
1 s max.
Adjustment level
inp.b2
Constant K
bank
Decimal
point
position
99999
20000
k
dp
No operation for 5 s
99999
No operation for 5 s
\\\\\
\\.\\\
\.\\\\
No operation for 5 s
Comparative
output pattern
out-p
To advancedfunction
setting level
amo?
nomal
No operation for 5 s
99999
No operation for 5 s
Password:
-0169
LEVEL
1 s min.
[MODE]
in-ta
4-20
Advanced-function
setting level
Setting State
4-20
12
in-ta
[MODE]
To next parameter
99999
1 s max.
Input adjustment
level
1 s min.
Comparative
set value display
See note 1.
Timing hold
No operation for 5 s
ON Timing
delay
Note 1:
Normal:
Sampling:
Peak:
Bottom:
Peak-to-peak:
No operation for 5 s
Display refresh
period
No operation for 5 s
No operation for 5 s
OFF Timing
delay
Green (red):
Green:
Red (green):
Red:
Display color
selection
No operation for 5 s
No operation for 5 s
Zero-limit
No operation for 5 s
Display value
selection
No operation for 5 s
Automatic
display return
No operation for 5 s
Position meter
type
PV
MAX
MIN
No operation for 5 s
Zero-limit value
No operation for 5 s
Step value
No operation for 5 s
Simple average
Moving average
Average type
See note 2.
Position meter
upper limit
No operation for 5 s
Note 2:
OFF:
Incremental:
Incremental (reversed):
Deviation:
Deviation (reversed):
No operation for 5 s
Averaging times
Position meter
lower limit
No operation for 5 s
No operation for 5 s
Comparative set
value level
1 s min.
Comparative
set value bank
Comparative
set value bank
Comparative
set value bank
Comparative
set value bank
Comparative
set value 7.HH
Comparative
set value 0.HH
No operation for 5 s
Comparative
set value 0.H
No operation for 5 s
Comparative
set value 7.H
No operation for 5 s
Comparative
set value 0.L
No operation for 5 s
Comparative
set value 7.L
No operation for 5 s
Comparative
set value 0.LL
No operation for 5 s
Comparative
set value 7.LL
No operation for 5 s
Bank copy
No operation for 5 s
Bank copy
No operation for 5 s
No operation for 5 s
K3HB-S
13
Initializing Settings
Password:
-0169
LEVEL
1 s min.
Advanced-function
setting level
Set value
initialization
PASS output
changes
init
off
pass
pass
Output
OFF-delay
Shot output
hys
off-d
0
shot
Output
out-n
de-energization n-o
Output
refresh stop
Tare zero
Zero
trimming
High-pass
filter
Bank
selection
o-stp
off
t-zr
off
z-trm
off
hp-f
off
bnk-c
off
Startup
compensation
timer
s-tmr
Input error
enable
s.err
Move to
calibration
level
0.0
on
cmo
off / on
No operation for 5 s
ll/ l/ pass/
h/ hh/ err
0000
9999
No operation for 5 s
0000
1999
No operation for 5 s
0000
1999
No operation for 5 s
n-o / n-c
No operation for 5 s
off / on
No operation for 5 s
off / on
No operation for 5 s
off / on
No operation for 5 s
off / on
No operation for 5 s
off / key / eV
No operation for 5 s
00.0
99.9
No operation for 5 s
off / on
No operation for 5 s
9999 99999
No operation for 5 s
14
Meaning
---
on
Initialize settings
Use this function when, for example, redoing all settings starting from
the delivery state.
No operation for 5 s
Hysteresis
Set value
off
Note: This operation will return all settings to their default values. The
present settings will be lost. Before performing this operation, it
is recommended that a record is made of the present settings.
The "key protect" function limits level and parameter changes using
key operations. There are 4 kinds of key protection. The parameters,
settings, and details of each kind of protection are outlined below.
Power ON
: Enabled, : Prohibited
RUN/Adjustment Protect
(Limits key operations in RUN level and movement to adjustment
level.)
RUN level
Restriction details
RUN level
LEVEL
MODE
LEVEL
1 s min.
Present
value
display
MODE
3 s min.
Protect level
RUN/
adjustment
protect
Setting level
protect
run.pt
0
RUN/adjustment
protect
run.pt
0 2
Set value
wt.pt
Forcedzero
protect
zr.pt
off
off
off / on
No operation for 5 s
off / on
No operation for 5 s
Restriction details
Move to
Move to the
initialization,
advanced
input
function setting
adjustment
level
display,
adjustment,
comparative set
values, and
output test
levels
No operation for 5 s
Setting
change
protect
Move to the
adjustment
level
0 2
No operation for 5 s
set.pt
Comparative
set value
change
Setting lev- 0
el protect
1
set.pt
2
Set value
Restriction details
off
on
Note: All protect level parameters and movement to the advancedfunction setting level and calibration level can be changed.
Forced-zero Protection
(Limits key-operated execution and clearing of forced-zero and tare
zero.)
Parameter
Zero
protect
=r.pt
Set value
Restriction details
off
on
K3HB-S
15
Error Displays
PV display
SV display
Description of error
Countermeasure
unit
(UNIT)
err
(ERR)
unit
(UNIT)
chg
(CHG)
disp
(DISP)
err
(ERR)
Display error
sys
(SYS)
err
(ERR)
eep
(EEP)
err
(ERR)
a.err
(A.ERR)
or
b.err
(B.ERR)
Normal
operation
Input error
(See note 2.)
99999
or
-19999
(flashing)
Note: 1. The parameters will be initialized. If the problem still persists after performing initialization, repair is necessary.
2. If there is an error in input A only, or if there is an error in both inputs A and B, a.err is displayed, and if there is an error in input B only,
b.err is displayed.
16
Nomenclature
Level/bank display
Max/Min status
HH
H
P
L
Hold
SV display status
Status display
Zero
SV display
T-ZR
PV display
Display
Position meter
Function
Turns ON when the tare zero function
is executed. Turns OFF if it is not
executed or is cleared.
Turns ON when the forced-zero function
is executed. Turns OFF if it is not
executed or is cleared.
TG
T-ZR CMW
Zero Hold
LL
TG
HH
LL
T
MAX/MIN
Function
Display
Max
Min
B
L
LEVEL
MODE
SHIFT
UP
HH, H,
L, LL
MAX/MIN Key
LEVEL Key
MODE Key
SHIFT Key
UP Key
Engineering Data
Allowable current (mA)
10
20
30
40
50
60
Note: The value for standard mounting. Note that the derating curve
differs depending on the mounting.
K3HB-S
17
Dimensions
Note: All units are in millimeters unless otherwise indicated.
101.2
91
120 min.
4.9
14.2
100
3.5
(112)
7.6
75 min.
92+0.8
0
45+0.6
0
12
1.3
95
2
96
44.8
48
Application Examples
Height Measurement/Discrimination of
Objects
Calculation
cal
Input type A
in-ta
4-20
4.000
-4.00
20.000
4.00
Decimal
dp
point position
%%%.%%
Characters
Set value
3.00
2.00
-2.00
-3.00
Remarks
Example of monitoring in
two stages, at the 2 mm
and 3 mm from the reference.
Parameter
Set
value
Remarks
Z4W-V25R
Output (mA)
20
4
-4
Displacement
(mm)
Characters
Timing hold
Characters
tmg-h
Set value
s-h
Remarks
Sampling hold
Characters
Set value
Remarks
pU
Present value
Position
meter type
pos-t
deU
Deviation display
pos-h
Position
meter upper
limit
4.00
Full-scale 4 mm
Position
meter lower
limit
-4.00
pos-l
Note: Only the parameters required for settings are displayed in the
initial setting, input adjustment, and display adjustment levels.
18
Displacement Sensor
Z4W-V25R
Displacement
Sensor
Z4W-V25R
Forced-zero
pushbutton
switch
Forced-zero
push button
switch
Sync Sensor
E3X-DA11-N
K3HB-S
Sync Sensor
E3X-DA11-N
24 VDC
Blue
Brown
K3HB-S
Black
TIMING
Operating power
supply
Operating power
supply
Input A
COM
+
-
ZERO
COM
Black
Connected internally.
Shield wire
Brown
Blue
2 mm
3 mm
Shape of workpiece
Insufficient
press-fitting
Press-fitting
omitted
Far
Displacement
sensor output
Near
Sync sensor
ON
OFF
K3HB-S
Display
0. 00
2. 00
-3. 00
K3HB-S
Comparative outputs
PASS
LL
Characters
Set
value
Remarks
Calculation
cal
Input type A
in-ta
4-20
4.000
E2CA
Output (mA)
0.40
20
20.000
2.00
Decimal
dp
point position
%%%.%%
4
0.4
K3HB-S
Displacement
(mm)
19
Characters
tmg-h
Set value
Remarks
Peak-to-peak hold
p-p
Note: Only the parameters required for settings are displayed in the
initial setting and input adjustment levels.
Linear Proximity Sensor
E2CA
TIMING input
pushbutton switch
24 VDC
+
Linear output
0V
K3HB-S
TIMING
12 V
Operating power
supply
Operating power
supply
K3HB-S
0V
(+)
Input A
COM
+
-
COM
Connected internally.
Pushbutton switch
(Measures only while ON.)
1 rotation
Status of workpiece
Linear Proximity
Sensor output
Far
A
Near
Pushbutton
switch
ON
OFF
ON while rotating once or more.
K3HB-S display
(Reset status)
When the workpiece has rotated once or
more, the desired value A is measured.
Characters
Set value
(See note.)
Comparative set value
H
20.50
(See note.)
Comparative set value
L
19.50
20
Remarks
Monitoring a difference
of 0.5 mm for a reference panel thickness of
20 mm
Characters
Set
value
Calculation
cal
Input type A
in-ta
4-20
4.000
21.00
20.000
29.00
Input type B
in-tb
4-20
4.000
21.00
20.000
29.00
Constant K
7000
Decimal
dp
point position
Remarks
K(A+B)
Displacement sensor
Z4W-V25R
Forced-zero
Pushbutton switch
Z4W-V25R
Output (mA)
K3HB-S
20
4
-4
Displacement
(mm)
%%%.%%
Characters
tmg-h
Set value
nomal
Remarks
Normal
Note: Only the parameters required for settings are displayed in the
initial setting and input adjustment levels.
24 VDC
Forced-zero
pushbutton switch
K3HB-S
Operating power
supply
Operating power
supply
Input B
Input A
COM
+
-
ZERO
Black
COM
Black
Shield wire
Brown
Blue
25
Sensor A
Brown
Blue
25 20
Displacement sensor
Z4W-V25R
Units (mm)
Sensor B
K3HB-S
21
21
Workpiece dimensions
20
19
Panel too thin
Panel thickness OK
A+B
Sum of distances measured
by two Z4W-V25R Sensors
49. 00
50. 00
51. 00
K3HB-S display
When K = 70.00
21. 00
20. 00
19. 00
H
Comparative
outputs
PASS
L
Measurement of Steps
Parameter
Timing hold
Characters
tmg-h
Set value
s-h
Remarks
Sampling hold
Note: Only the parameters required for settings are displayed in the
initial setting and input adjustment levels.
Characters
Forced-zero
pushbutton
switch
Set value
2.50
1.50
Remarks
Monitoring a difference
of 0.5 mm for a reference step of 2 mm
Characters
Set
value
Calculation
cal
Input type A
in-ta
4-20
4.000
21.00
20.000
29.00
Input type B
in-tb
4-20
4.000
21.00
20.000
29.00
Decimal
dp
point position
%%%.%%
22
K3HB-S
Sync Sensor
E3Z-D62
Remarks
AB
Z4W-V25R
Output (mA)
20
4
-4
Displacement
(mm)
24 VDC
Sync Sensor
E3Z-D62
Blue
K3HB-S
TIMING
Forced-zero
pushbutton switch
Brown Black
Operating power
supply
Operating power
supply
Input B
Input A
COM
+
-
ZERO
Black
COM
Black
Connected internally.
Displacement Sensor
Z4W-V25R
Brown
Blue
Sensor A
Brown
Blue
2
Sensor B
Shield wire
Units (mm)
Displacement
sensor B
Displacement
sensor A
3.00
(20 mA) 29 mm
Displacement sensor
(12 mA) 25 mm
(A) output
(4 mA) 21 mm
(20 mA) 29 mm
Displacement sensor
(12 mA) 25 mm
(B) output
(4 mA) 21 mm
2.80
3.20
(Carrier movement)
26.0 mm
25.6 mm
26.4 mm
23.0 mm
22.8 mm
23.2 mm
(Carrier movement)
3. 00
2. 80
3. 20
ON
H
K3HB-S
comparative outputs
PASS
OFF
ON
OFF
ON
OFF
* The previous judgement result is held until
the Sync Sensor turns ON. (All outputs turn
OFF when RESET input is received.)
K3HB-S
23
Operating Procedures
In addition to calculations such as K (constant)A (input for one circuit), it is possible to perform calculations based on the inputs for
both circuits, such as A+B and AB, making it possible to perform
thickness measurement and level-difference measurement using
displacement and length-measuring sensors.
Main Functions
Measurement
Input Calculation
The K3HB-S has two input circuits. The input ranges for these circuits can be set independently. For example, one can be set to 4 to
20 mA and the other can be set to 1 to 5 V.
A
K
K-A
Timing Hold
Normal
Input
Comparative set value H
Measurement value
Measurement value
TMING ON
input OFF
Output H
Peak-to-peak Hold
Sampling Hold
Measures the difference between the maximum and minimum values in a specified period.
Input
Peak-to-peak value
(b2a2)
(b1a1)
Measurement value
Measurement value
b1
a1
'b2
'a2
Time
Time
TIMING ON
input OFF
TIMING ON
input OFF
Scaling
Average Processing
Display value
Display value
Display value 2
Display value 2
(dsp.@2)
(dsp.@2)
Display value 1
Display value 1
High-pass Filter
High-pass filter is a function that detects only sudden changes to
input signals.
(dsp.@1)
(dsp.@1)
Input value 1 Input value 2
(inp.@1) (inp.@2)
Scaling
Input
value
(inp.@2) (inp.@1)
Input
value
Reverse Scaling
Teaching
Settings for scaling can be made using the present measurement
values instead of inputting values with the SHIFT and UP Keys. This
is a convenient function for making the settings while monitoring the
operating status.
24
Input Compensation/Display
Forced-zero
Tare Zero
The tare zero function shifts the present measurement value to 0
again using the forced-zero reference. Using the tare zero function, it
is possible to weigh two or more compounds independently and then,
by releasing the tare zero and forced-zero, measure the total combined weight.
Values can be displayed in either red or green. With comparative output models, the display color can also be set to change according to
the status of comparative outputs (e.g., green to red or red to green).
Example) Setting: grn-r
Red
H
Zero-trimming
110.00
110.01
Green
100.05
110.00
99.87
Zero-limit
110.00
Red
The zero-limit function displays 0 for input values lower than a set
value. It is enabled in normal mode only. (This function can be used,
for example, to stop negative values being displayed or to eliminate
flickering and minor inconsistencies near 0.)
Display
Step Value
It is possible to specify (i.e., restrict) the values that the smallest displayed digit can change by. For example, if the setting is 2, the smallest digit will only take the values 0, 2, 4, 6, or 8 and if the setting is 5,
it will only take the values 0 or 5. If the setting is 10, it will only take
the value of 0.
Zero-limit
setting
Input
Output
Comparative Output Pattern
Hysteresis
The output pattern for comparative outputs can be selected. In addition to high/low comparison with set values, output based on level
changes is also possible. (Use the type of output pattern appropriate
for the application.)
This function prevents comparative output chattering near the comparative set values.
Comparative
set value HH
Comparative
set value H
Comparative
set value L
Comparative
set value LL
Standard Output
Measurement
value
Higher
Comparative
set value HH
Comparative
set value H
Comparative
set value L
Comparative
set value LL
Lower
Level Output
Measurement
value
Higher
Lower
Hysteresis
Hysteresis
ON
OFF
Output HH
Output H
Output HH
ON
OFF
Output H
Output PASS
Output PASS
Output L
Output L
Output LL
Output LL
Input
Comparative
set value HH
Comparative
set value H
Comparative
set value L
Comparative
set value LL
Output HH
Output H
Zone Output
Measurement
value
Higher
Comparative
set value H
Lower
Time
ON
OFF
Output PASS
S-TMR input
Startup compensation
time set time
Output H
Output L
Output LL
Output De-energization
Comparative results other than PASS and error signals can be output
from the PASS terminal.
The operation of comparative outputs with respect to the comparative result can be reversed.
K3HB-S
25
Precautions
!WARNING
Do not touch any of the terminals while the power is being supplied. Doing so may result in electric shock.
!Caution
Do not disassemble the product or touch the internal components
of the product while the power is being supplied. Doing so may result in electric shock.
!Caution
Do not use the product in locations where flammable or explosive
gases are present. Doing so may result in explosion.
!Caution
Do not allow metal objects or wire cuttings to enter the product.
Doing so may result in electric shock, fire, or malfunction.
!Caution
Perform correct settings for the product according to the control
application. Failure to do so may cause unexpected operation, resulting in damage to the product or injury.
!Caution
Take safety measures, such as installing a separate monitoring
system, to ensure safety even if the product fails. Product failure
may prevent comparative outputs from being generated, resulting
in serious accidents.
Observe the following precautions to ensure safety.
1. Maintain the power supply voltage within the range specified in
the specifications.
2. Maintain the load within the ratings specified in the specifications.
3. Check each terminal for correct number and polarity before connecting it. Incorrect or reverse connections may damage or burn
out internal components in the product.
4. Tighten the terminal screws securely. The recommended tightening torque is 0.43 to 0.58 Nm. Loose screws may cause product
failure or malfunction.
5. Do not connect anything to unused terminals.
6. Provide a switch or circuit breaker so that operators can easily
turn OFF the power supply when necessary. Also provide appropriate indications of such devices.
7. Do not attempt to disassemble, repair, or modify the product.
8. Do not use the product where flammable or combustible gases
are present.
9. When mounting Optional Boards, do not touch electronic components or patterns on the PCB. Hold the PCB by the edges.
Application
General Precautions
1. Do not use the product in the following locations:
Locations subject to direct radiant heat from heating equipment.
Locations subject to exposure to water, oil, or chemicals.
Locations subject to direct sunlight.
Locations subject to dust or corrosive gases (particularly sulfuric gas or ammonia gas).
Locations subject to severe changes in temperature.
Locations subject to icing or condensation.
Locations subject to shock or vibration.
2. Do not block heat dissipation around the product, i.e., provide sufficient space for heat dissipation.
26
3. Ensure that the rated voltage is reached within two seconds after
the power is turned ON.
4. Conduct aging for 15 minutes min. after power is turned ON for
correct measurement.
5. Do not touch the slit sections or terminals while the power is
being supplied to prevent the product from being affected by static
electricity.
6. Do not lay heavy objects on the product during use or storage.
Doing so may deform or deteriorate the product.
7. Do not use paint thinner for cleaning. Use commercially available
alcohol.
Mounting
Mount the product to a panel that is 1 to 8 mm thick.
Install the product in a horizontal position.
Use crimp terminals that match screw sizes.
Noise Prevention
Install the product as far as possible from devices that generate
strong, high-frequency fields (such as high-frequency welders or
sewing machines) or surges.
Install surge absorbers or noise filters on nearby devices that generate noise (particularly, motors, transformers, solenoids, magnet
coils, and other devices that have a high inductance component).
Line filter
Power
supply
input
Linear
Sensor
Indicator
+
Signal
input
Linear
Sensor
Indicator
Power
supply
input
Surge absorber
Signal
input
2-conductor
shielded cable
When using a noise filter for the power supply, check for the voltage
and current and install it as close as possible to the Linear Sensor
Indicator.
Do not install the product near radios, television sets, or wireless
devices. Doing so may cause reception interference.
Wiring Precautions
Mounting Method
1. Insert the K3HB-S into the mounting cutout in the panel.
2. Insert watertight packing around the Unit to make the mounting
watertight.
For terminal blocks, use the crimp terminals suitable for M3 screws.
Tighten the terminal screws to the recommended tightening torque
of approx. 0.5 Nm.
To prevent inductive noise, separate the wiring for signal lines from
that for power lines.
Wiring
Use the crimp terminals suitable for M3 screws shown below.
5.8 mm max.
3. Insert the adapter into the grooves on the left and right sides of
the rear case and push until it reaches the panel and is fixed in
place.
5.8 mm max.
Unit Stickers
There are no unit stickers attached to the Sensor at the time of
delivery.
Select the appropriate units from the unit sticker sheets provided.
10
Note: When using for meters, such as weighing meters, use the units
specified by regulations on weights and measures.
30
Waterproof Packing
The waterproof packing ensures a level of waterproofing that conforms to NEMA 4X. Depending on the operating environment, deterioration, contraction, or hardening may occur and replacement may
be necessary. In this case, consult your OMRON representative.
K3HB-S
27
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply
to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end
product, machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all
possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products.
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED
AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69, NL-2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
28