Académique Documents
Professionnel Documents
Culture Documents
23/6/2008
Sheet no.:
1 of
Computed by:
H.S
Checked by:
Main Pool
Approved by:
Pool Dimensions
Pool Area
Pool Average Depth
Pool Volume
=
=
=
165
0.941
155.2
m2
m
m3
Recirculation System
Pumps Capacity
Turnover Rate
Recirculation Rate
Safety Factor
Total Recirculation Rate
No. of Acting Pumps
Pump Flow Rate
=
=
=
=
=
=
6
7.2
20%
8.7
2
4.4
L/s
Friction Loss
Filter Pressure Drop
Heater Pressure Drop
Piping Network Loss
Static Pressure
Safety Factor
Pump Head
m3
hrs
L/s
L/s
Treatment Plant
Filtration System
Type of Filter :
Pressure Sand (High Velocity)
L/s/m2
Flow Rate
=
13.6
Kpa
Pressure Drop
=
98.1
=
10
2
L/s/m
Backwash Rate
=
min
Backwash Time
=
2.5
m2
Filtration Area
=
0.7
2
No. of Filters
=
L/s
Flow per filter
=
4.4
m2
Area per filter
=
0.4
L
Backwash Pit
=
652.5
=
0.7
m3
=
=
=
=
=
=
10
5.3
3
0
20%
22.0
5
7
3
5
m
m
m
m
m
23/6/2008
Sheet no.:
2 of
Subject:
Computed by:
H.S
Checked by:
Approved by:
=
=
=
10
4.4
4125
hrs
L/s
L/day
Drainage
Main Drain Flow
Pool Emptying Time
=
=
5.8
7.4
L/s
hrs
Pool Chemistry
Disinfection and PH Control Systems
Chlorination Type :
Calcium Hypochlorit
ypochlorinator Capacity
=
2.3
L/h
Effect on Pool PH
=
Increase Alkalinity (PH Increase)
PH Balancing Chemical
=
Sodium Bisulfate
Sodium Bisulfate Rate
=
1.9
Kg/dose
Require Mixing Container Before Hypochlorinator
Pool Heater
Pool Heat-up Rate
Water Density
Specific Heat of Water
Desired Pool Temp.
Initial Pool Temp.
Pool Heat-up Time
Pool Heat-up Rate
=
=
=
=
=
=
Heater Capac
General Notes
998
4.18
27
20
48
26.3
26.3
29.7
56.0
Kw
Kw/m2.K
m2
C
C
Kw
1.
2.
3.
4.
5.
Pool inlets should be spaced less than 6 m apart and within 1.5 m of a corner
Vacuum cleaning outlets should be located so that a hose of maximum 15 m can reach any po
Supply and return piping of the pumps should have a maximum velocity of 5 to 6 ft/s
Surge tanks are not required with vacuum diatomic filters, skimmers or continuous flow gutter
Chlorine gas usage is limited to large pools and some local codes don't permit its use
Turnover Rate
Pool Type
Main Pool
Average No. of Bathers
High No. of Bathers
Low No. of Bathers
Learning Pool
Diving Pool
Shallow Pool with Large Area
3
2
6
1.5
6
1.5
System
[gal]
10,000
18,000
42,000
72,000
114,000
180,000
360,000
720,000
Volume
[L]
37,850
68,130
159,000
272,500
431,500
681,300
###
###
Suggested
Maximum Size
[gph]
[L/h]
0.15
0.6
0.25
1.0
0.60
2.3
1.0
3.8
1.6
6.0
2.5
9.5
5
20
10
40
Version 1.0
Released April 2007