Vous êtes sur la page 1sur 1

03

/04
/16

\A1;40

+17.0mDM

6T20OP

23

LEV-3SAB(.)

21

\A1;50

\A1;7295

LEV-3SAB(.)

B4

18

UB
1

+1
5
SS . 6 0

STAIR-4

B2

ELIN
H
TC
MA

- 1

Q1

O1

CH

\A1;250

SLABREINFOCMT

0.4

REVISED AS CLOUDED

26-07-2015

RM

ISE

0.3

REVISED AS CLOUDED

28-04-2015

RM

ISE

0.2

REVISED AS CLOUDED

28-01-2015

SN

ISE

20-10-2014

RM

ISE

31-8-2014

MA

OH

14-8-2014

MA

OH

18-6-2014

MA

OH

20-2-2014

MA

OH

2T16

T12@50SIRUP

\A1;40

DETAIL(UB1)

0.1

SCALE1:25

SLABREINFOCMT

STAIR-5

T8@20LINK

ISSUED FOR CONSTRUCTION


SLAB EDGE REVISED AS CLOUDED

UP

SECTION-PD1

B1 0

SS

6.

\A1;40

F2

S-209C

REVISED AS CLOUDED

SCALE1:0

B1 0

ISSUED FOR CONSTRUCTION

UP

E2

ISSUED FOR TENDER

B8

t
a
D
e
u
s
I

n
o
t
p
i
r
c
s
e
D

1
B1
1

B8

B1

R=
6

12

PS

40

DN

PS

B1

= SUPPORTING COLUMN

PS

S-51

B4

00

B8

LB
PS

2T2

LS1

BEAM SCHEDULE

BOTTOM REINF.
TYPE

SIZE (mm)

A
PS

5
SS . 6 0

6@
T1

3T2
R=

68

40

70
R=
4T2

99

B1

B2

B2
= STOP COLUMN

A2

1T2

5
SS . 6 0

PS

+1

B1

PS

PS

S-51

PS

DP

B4

B1

S-51

10T25

S-51

\A1;40

PS

B1

LS
2

B1

B1

\A1;850

MID SPAN

RIGHT

11T32
10T25

11T32
10T25

RIGHT

LINK
SIDE BARS

ARRANG.
EACH FACE

SPAN

11T32

T10@100

T10@100

T10@100

3T12

10T25

T10@150

T10@200

T10@150

3T12

CLOSED STR.

T10@150

T10@150

2T12

CLOSED STR.

5T25+4T25

5T25

5T25+4T25

4T25+4T20

4T16

4T25+4T20

T10@100

T10@300

T10@100

2T12

2T25

4T25

4T16

4T25+4T20

T10@100

T10@200

T10@100

2T12

4T25

2T25

4T25+4T20

4T16

4T25+2T20

T10@100

T10@200

T10@100

2T12

400X800

4T25

2T25

6T25+4T25

4T16

6T25+4T25

T10@100

T10@200

T10@100

B8

600X1000

6T25

4T25

6T25+6T25

4T20

6T25+6T25 See Section See Section

B9

600X1900

6T32

6T32+5T32

6T32

T12@100

T10@200

T12@100

B10

800X2400

2x8T32

+4T32

2x8T32

+4T32

T12@100

T12@100

T12@100

B11

800X2400

8T32

+2T32

8T32

+2T32

8T32+8T32
+8T32
2x8T32
8T32+8T32
+2T32

+4T32

8T32

T12@100
+2T32

8T32+8T32

T12@75
+8T32

8T32+8T32

T12@75
+2T32

T12@100

T12@100

T12@150

T10@100

450X800

B4

400X800

B5

400X800

B6

400X800

B7

5T25
4T25

+2T20

4T25

+2T20

PLOT NO. 3450840 @

Client:

5T25

B3

2B+G+M+3P+66/20+R

REMARKS

LEFT

EMAAR Properties PJSC ,

P.O. Box 9440, Dubai,

United Arab Emirates

Tel 971 4 3673333

Fax 971 4 3673000

enquiry @ emaar.ae

5x10T32

+4T32

5x10T32

+4T32

8T32

+2T32

8T32
+2x8T32
8T32

+2x2T32

6T32
5x10T32

+4T32

Refer Sheet S-510

www.emaar.com

T12 @300

CLOSED STR.

T20@250

CLOSED STR.

T20@250

CLOSED STR.

T12@75

T20@250

CLOSED STR.

T12@150

T12@75

T20@250

CLOSED STR.

T10@200

T10@100

T12 @300

CLOSED STR.

See Section

T10@200

T10@100

T12@150

T12@75

B12

800X2400

3x8T32

B13

800X2400

2x8T32
+4T32

B14

600X1900

6T32

7T25

6T25

7T32

B15

600X1000

7T25

5T25

6T25+6T25

6T25

6T25+6T25

B16

400X800

6T25

4T25

6T25+6T25

4T20

6T25+4T25

B17

800X3000

2x8T32

8T32+8T32

8T32+8T32

8T32+8T32
T12@75

LB1

500X3000

6T25

+6T25

6T25+4T25

6T25+4T25

6T25+4T25

T12@100

T12@100

T12@100

T20@200
Refer Sheet S-419

LB2

600X3000

6T32

3T25

6T32+3T25

6T32+3T25

6T32+3T25

T12@100

T12@100

T12@100

T20@200
Refer Sheet S-419

LB3

400X3000

4T25+3T32

4T25+3T32

4T25+3T32

T12@150

T12@150

T12@150

T20@200

LB4

300X3000

3T25+2T32

3T25+2T32

3T25+2T32

T10@150

T10@150

T10@150

T20@200

LB5

300X1400

3T25

3T25

3T25

3T25

T10@150

T10@150

T10@150

T20@200

B18

600X1200

6T32

6T32

6T32+6T32

6T32

DesignCoulta:

bh ns

BH.NS ENGINEERING CONSULTANTS

D U B A I
T: + 97143344777

B1

LEFT

T10@150

\A1;57

PL1

850X1000

11T32

LS

B1

PLOTBUNDARY

850X1000

LINKS

TOP REINF.

PS

PS

B1

B1

= PLANTED COLUMN

PS

PS

B4

\A1;387

B1

+1

S.
S
0m
m

40

PS
PS

T1
15
6
TY @1 0 B
O
PI
5
T.
CA 0 T
B/
O
L
P
W
M
ES B/ W
H

\A1;850

BURJ VISTA

C2

\A1;850

T10@100

M E L B O U R N E
F: + 97143344255

L O N D O N

E: info@bhns.ae

P.O.Box 291 Dubai UAE

Refer Section

2T12

Drawingtle:

\A1;850

T20@250

CLOSED STR.

\A1;4820

LEGEND

\A1;850

{\LEGND}

\A1;850

PLOTBUNDARY

HATCHED PORTION NOT

INCLUDED IN THE SUBMISSION

4T25

+3T32

3T25

+2T32

6T32+6T32
3T10@200

3T10@300

3T10@200

FRAMING LAYOUT

THIRD FLOOR PLAN

T16@300

OrignalSce

e
z
i
S

d
k
c
e
h
C

n
w
a
r
D

d
e
s
i
r
o
h
t
u
A

H
O

B19

PL2

600X1000

6T25

4T25

6T25+4T25

6T25

6T25+4T25

2T10@200

2T10@300

2T10@200

T16@300

K
A
M

X
E
L
A

A1

0
4
:
1

3
1
0
2
E
N
U
J

B8A

600X1000

6T25

4T25

6T25+4T25

6T25

6T25+4T25

2T10@200

2T10@300

2T10@200

T16@300

:
e
t
a
D

DrawingNo.:

:
e
t
a
D

.
v
e
R

691-S-209

ISSUED FOLDER NO. : 86

:
e
t
a
D

0.5

C:\Users\iinairat\AppData\Local\Microsoft\Windows\Temporary Internet Files\Content.Outlook\WB3OJVAC,3/1/2016 11:05 AM

COLUMN LEGEND

LB

PS
STAIR-8

B4

d
e
z
i
r
o
h
t
u
A

Project:

DN

\A1;850

n
w
a
r
D

D2

PS

13

Rev

CAD REF:

PS

2
\A1;25

\A1;850

LB

PS

B4

B8

PS

+1

LEV-3SAB(.)

7T25BO.

G2

5
2
;
1
A
\

+15.60mDM

LINE

REINF.TOLAYU

2T16

40

UP

B9

SS
0m
m

00

PS

LB

LEV-3SAB(.)

7T25OP

M AT

+17
.1
SS 0 0

PT
250
mm

S-51

B2

H2

P1

B2

B14

6@
T1

ALL BA
LCON
Y AR
EA TO
TO BE
P OF
REDU
SLAB
CED
LEVE
20mm
L

FORM
SSL
(TYP.)

L B3

L B3

LB

T1
15
6
TY @1 0 B
O
PI
5
T.
CA 0 T
B/
O
L
W
P
M
ES B/ W
H

UPB

PS

PS

B14

NI

S-510
S

J2

+16.0mDM

\A1;40

UB1

UB 1

UP

LB3

B1

B1 4

L2

PS
B1

S-51

PS

B8

10
B

B1

0D
N.

PS

NI

UPB

UB1

DP

PS

UB1-20x4

K2

B8

B1

40

PS

SS
0m
m

40
T1
6
T1 @1
5
6
TY @1 0 B
O
PI
5
T.
CA 0 T
B/
O
L
W
P
M
ES B/ W
H

PS

B4

C1

MA

PS

B4

B6

D1

5T2

E-

B6

A1

M2

LIN

\A1;850

E1
28

TC
H

234

M
AT
CH

S-209

R=

-2

PSD1

\A1;40

\A1;8325

M1
K1

J1

G1

B1

F1

S
T

PS

B7

7A

UP

400 DN.

B1

NE

\A1;350

7.1
+1
L
SS

N2

B17

LI

01

\A1;8325

N1

LB
A
DU L CO
NY
CE
D
AR
20
mm E A
FR TOP
OM
OF
SL
BO
A
TT
OM B LE
VE
OF
LT
SS
L (T O B
YP E
.)

AL

RE

L1

PT m

0m

25
00

10

7'

P1

S-209

77

\A1;4238

STAIR-1

LB
STAIR-2

B1

B1

1
R=

S-51

\A1;850

UP

PS

PS

B1 0

B1

KEYPLAN

STFB

F
ST

\A1;850

+17.1
00

SSL

PT
250m
m

UB

L B4

22
1
LB

LB

LB

PS

B11

RELEVANT DRAWINGS, TOGETHER WITH THE SPECIFICATION.

FB

FB
ST

F
ST

6. ALL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL OTHER

\A1;590

LB
LB

S-209

B1

B8

PS

B4

B1

B1

B8

\A1;50

7B

PRIOR TO COMMENCEMENT OF WORK.

LB

AB

ST

S-51B

PLOTBUNDARY

\A1;590

A-3

\A1;850

DISCREPANCIES OF ERRORS, SHALL BE INFORMED TO THE SITE ENGINEER

PS

PS

5. .ALL DIMENSIONS AND LEVELS ARE TO BE CONFIRMED AND ANY

PLOTBUNDARY

H1

PS

TF
S

UPB

S-209B

PS

EXECUTION OF WORK AT SITE.

\A1;850

B2

40

PS

-2

10

SERVICES SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO

B1

UPB

PS

/W
T. B
BO P B/W
50
O
@1 0 T
H

T16 @15
ES
6
M
1
L
SS m T YPICA
T
0m

4. ANY DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL &

B1

S-51

.60
+15
L
S
S

B1

STAIR-7

B5

LB

5
DN

PS

B1

-2

PS

PS

PS

INE

LB

.
+15
L
SS

B8

NE

B6

LI

S-51

TO BE FOLLOWED.

\A1;850

DP

A
B8

PS

PS

UPB

11

/W
T. B
BO P B/W
50
@ 1 0 T O H

T16 @15
ES
6
M
1
T
AL
PIC
TY
60

B8

\A1;50

ST

MA
TC \A1;850

HL

\A1;25

UNLESS NOTED OTHERWISE.

3. DO NOT SCALE FROM THIS DRAWING. ONLY WRITTEN DIMENSIONS ARE

SCALE1:0

ST
X

M
AT
CH

2. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS

SECTION-PD3

12

\A1;850

S-209B

SS
mm

400

LB

B8

B8

B4

13

B8

\A1;8496

B8

PS

16.

00

\A1;40

THIS DRAWING IS COPYRIGHT PROTECTED.

\A1;850

00

SS

PS
P

D2

1.

S-209C

LB

SSmm
400

14

11

GENERAL NOTES:

.6
+ 15
L
SS

6T20BO.

R1

UP

PS

SSmm
500

PS

/W
T. B
BO P B/W
50
O
@1 50 T
6
H
1
1
S
T 6@
ME
T1
AL
PIC
TY

PS

PLOTBUNDARY

\A1;850

PS

PS

+1
7
SS . 1 0 0

B1

UB

/W
T. B
BO
B/W
50
@1 0 TOP

T16
15
SH
E
@
6
M
T1
AL
PIC
TY

PS

PS
D1

S-209

B8

SCALE1:0

DN

S-209

15

SECTION-PD2

40

PT
0m
m

B8

NI

S-209

PS
6T20BO.

PSD
3

B8

\A1;40

B8

PS

T12@50SIRUP

T12@50SIRUP

\A1;40

- 1

SS
B4

B1

41

60
15.

00

PLOTBUNDARY

B1

23

LINE

L B5

B1
B
1

R=

CH

SSmm

400

B1

B1

B1

B4

B8

LB

B
STAIR-6

5.8

NI

\A1;850

+1
B=

UP

MAT

16

LEV-3SAB(.)

TO

B1

\A1;850

DN

\A1;850

B1

B1

B1

B4

0M

STAIR-6

- 1

INE
HL
TC
MA

17
6T1FACEBRS

+16.0mDM

B1

B4

\A1;850

\A1;0

B1

R=74450

R=71300

PLOTBUNDARY

\A1;05

\A1;850

\A1;9350

4T1
5T1

\A1;6240

19

APPROVED

+16.0mDM

R=63000

R=60850

750

29
R=

\A1;0

8T16FACEBRS

2T1 3T1

1T1

20

S-209C

34
50
84
0
23
53
71
-42
-1

22

+17.0mDM

\A1;40

6T20OP

LEV-3SAB(.)

Vous aimerez peut-être aussi