Vous êtes sur la page 1sur 2

Config 600 Pro Training Manual

Prover Inlet - Prover Outlet (Temperature and Pressure)


Prover Inlet - Stream (Temperature and Pressure)
Prover Outlet - Stream (Temperature and Pressure)
9.45.2.2

Variable Rate of Change


XNEW - X OLD
XRATE
Period

where:
XRATE the rate of the variable
XNEW the new sample value
XOLD the previous sample value
Period the sampling interval
The variables compared are:
Prover Inlet

(Temperature and Pressure)

Prover Outlet

(Temperature and Pressure)

Stream Flowrate

9.45.3 Repeatability calculations


When the required number of consecutive good runs has been achieved, each individual
run K.Factor or Meter Factor (which make up the N consecutive good runs) is checked to
see how far it deviates from the average. The K-Factor is checked for volume based
pulses and the Meter Factor is checked for mass based pulses. If any run deviates by
more than the allowable limit then additional runs are performed and the test repeated.
When all the required run K.Factors / Meter Factors fall within the deviation limit, then
the prove is deemed successful and Final average data is calculated. At the same time the
single maximum deviation value of the good run K.factors / Meter factors are stored as an
indication of how well the prove fell within the deviation tolerance.
9.45.3.1 API 1 (API Method)
Max deviation from (KFaverage KFrun ) / KFaverage.
9.45.3.2

MX-MN/AVG (IP Part X appendix C)


K - K RUN
K DEV = AVG
x 100
K AVG

where:
KDEV is the K.Factor deviation (%)
Rev Febuary/06

Calculation Table

296

Config 600 Pro Training Manual


KAVG is the average K.Factor of N consecutive good runs (pls/m3 )
KRUN is the run K.Factor being checked (pls/m3 )

9.45.3.3 MX-MN/MX+MN2
max_devn = (fabs(max min) / ((kf_max + kf_min) / 2.0)) * 100.0
9.45.3.4 MX-MN/MN
max_devn = (fabs(max min) / kf_min) * 100.0
9.45.3.5 MX-MN/MX*MN
max_devn = (fabs(max min) / (kf_max * kf_min)) * 100.0
9.45.3.6

MX-AV/AV
K - K MIN
K DEV = MAX
x 100
K AVG

where:
KDEV is the K. Factor deviation (%)
KAVG is the average K. Factor of N consecutive good runs (pls/m3 )
KMAX is the maximum run K. Factor being checked (pls/m3 )
KMIN is the minimum run K. Factor being checked (pls/m3 )
9.45.3.7 AV-MN/AV
max_devn = ( fabs (kf_avg - kf_min) / kf_avg) * 100.0

9.45.4 Run CTLp


Correction Factor for the Effect of Temperature on the Liquid at the Prover is calculated
by passing the following parameters to the Volume Correction Factor calculations at 9.42
Coefficient of thermal expansion of the liquid (/C)
Tp

Temperature of the liquid at the prover (C)

Tstd

Standard temperature (15C)

K0, K1

are liquid specific constants ((kg/m2)/C)

K2

liquid specific constant (/C)

RHOstd

density at standard conditions (kg/m3 )

9.45.5 Run CPLp


Correction Factor for the Effect of Pressure on the Liquid at the prover:
Rev Febuary/06

Calculation Table

297