Académique Documents
Professionnel Documents
Culture Documents
FACULTY OF SCIENCES
BAYERO UNIVERSITY, KANO
BY
SUPERVISED BY
MALL. A.A MUHKTAR
CERTIFICATION
I hereby certify that the Students Industrial Work Experience Scheme (SIWES) report
submitted to the Department of Biochemistry, Bayero University Kano, as a requirement for
the award of degree of Bachelor of Science in Biochemistry, has been composed by myself
and has not been presented or accepted in any previous application for a degree. The work, of
which this is a record, has been carried out by myself unless otherwise stated and where the
work is mine, it reflects personal views and values. All sources of information have been
acknowledged by means of references including those of the Internet.
.
Signature/Date
..
Signature/Date
..
Signature/Date
DEDICATIONACKNOWLEDGEMENTS
TABLE OF CONTENTS
TITLE PAGEi
CERTIFICATION....................................................................................................................ii
DEDICATION.........................................................................................................................iii
ACKNOWLEDGEMENT........................................................................................................iv
LIST OF FIGURES...................................................................................................................v
GLOSSARY.............................................................................................................................vi
PREAMBLE
The Industrial Training Fund (ITF)...........................................................................................
Functions of the ITF
...........................................................................................................
CHAPTER ONE
Place of Industrial Training........................................................................................................
Brief History of the Organization..............................................................................................
CHAPTER TWO
EQUIPMENT, REAGENTS AND PREPARATION.........................................................
1.1
Equipments........................................................................................................
1.1.1
1.1.2
1.1.3
Reflotron Machine.............................................................................................
1.1.4 Accu-check
1.1.5 Centrifuge Machine
1.1.6 Autoclave...
1.1.7 Incubator
1.1.8 Thermostatic Drying Oven
1.1.9 FACS Count Machine (CD4 Machine).
1.2
CHAPTER THREE
METHODS/ANALYSIS OF ROUTINE WORK DONE IN THE VARIOUS SECTION
OF THE LABORATORY
2.1
2.2
Haematology Section...
2.3
2.4
Immunology Section
PREAMBLE
Based on the foregoing, the student work experience programme which basically prepares
students for the world of work has become an innovative phenomenon in the process of
manpower development and training in Nigeria, hence, the introduction of the Students
Industrial Work Experience Scheme (SIWES) into the educational training system
FUNCTIONS OF ITF
Key functions of ITF include:
Organizing research and studies into training as a support to other activities of the Fund;
Seeking to harmonize ITFs non-formal training programmes with the curricula of formal
educational institutions;
Bearing a proportion of the direct cost of on-the-job and off-the-job training of Nigerian
employees.
(ITF, 2010)
OBJECTIVE OF SIWES
To provide students with an opportunity to apply their knowledge in real work situation,
IMPORTANCE OF SIWES
SIWES have a lot of importance among which are:
It exposes students to real life situation, thus supplementing the theoretical lesson.
It helps to improve the quality of skilled manpower of the students.
It gives students practical knowledge of course of study.
It provides a forum for industries to evaluate prospective employers and gives feedback
to institutions.
It establishes a close collaboration between institutions and industries, a factor which is
essential for preparing student for the workforce.
CHAPTER ONE
THE HISTORICAL BACKGROUND OF UMARU SANDA NDAYAKO
HOSPITAL BIDA
Umaru Sanda Ndayako General Hospital Bida was established and commission by
His Excellency former head of the state and commander in chief of arm forces.
General Yakubu Gawon G.C.F.R. on the 28th day of March 2009.
The General Hospital also known as Umaru Sanda Ndayako is located along Minna
Road opposite Zamfara Mosques Bida, at the point of commission the hospital is well equipt
with hospital material and well qualified staff.
CHAPTER TWO
EQUIPMENTS, REAGENTS AND THEIR PREPARATION
2.0
EQUIPMENTS
The Equipment used in the laboratory throughout the SIWES period is as follows:
2.1.1
Ethylene Diamine Tetracetic Acid (EDTA) bottles with purple caps, Serum Separation Tube
(SST) with (Red Cap,) lithium heparin Tubes (Green Cap), Erythrocyte Sedimentation Rate
(ESR) Tube (Black cap) and Sterile Universal Container (red and White Caps) as shown in
the figure 1.1 below
2.1.2
2.1.3
Reflotron Machine
Accu-check
Fig
2.4: Accu
2.1.5
Centrifuge Machine
Autoclave
check
Fig 2.6:
Autoclave
2.1.7
Incubator
Leishman's stain
Leishman's stain is used in microscopy for staining blood smears. It provides excellent stain
quality and is generally used to differentiate and identify leucocytes, malaria parasites, and
trypanosomas. It is based on a mixture of methylene blue and eosin.
Preparation
To make about 400ml:
Leishman stain powder..0.6g
Methanol (methyl alchohol....400ml
Note: The methanol MUST be water free
1.
Weigh the Leishman powder and transfer it to a completely dry brown bottle. Add a
few dry glass breads (to assist in dissolving the dye)
2.
Using a dry cylinder, measure the methanol and add this to the stain. Mix well at
intervals until the dye is completely dissolved. Warming the solution in a 37 0C water
bath will help the dye to dissolve.
Caution: Methanol is toxic and highly flammable; therefore handle it with care well
away from an open flame.
3.
Label the bottle and mark it Flammable and Toxic. Store it at room temperature in the
dark. When kept tightly stoppered, the stain is stable for several weeks. Moisture must
not be allowed to enter the stain.
For use: Filter 50-100ml of the stain into a stain dispensing container which can be closed
when not in use.
Sodioum citrate anticoagulant, 32g/l
To make 100ml
Tri-Sodium citrate, dehydrate3.2g
Distilled waterto 100ml
1.
Weigh the chemical and transfer it to a container pre-marked to hold 100ml (or to a
100ml volumetric flask).
2.
Add about half the water and mix until the chemical is completely dissolved.
3.
4.
Label the container and store it at 2-80C. Discard the reagent if it becomes
contaminated (turbid appearance).
Normal saline
Preparation
gm/ltr
Agar
15.00
Peptone
5.00
Sodium chloride
5.00
Beef extract
1.50
Yeast extract
1.50
pH
7.4
Distilled water
1ltr
Preparation
28.0gm was dissolved in 1000ml distilled water. It was heat gentle to dissolve the medium
completely. Sterilized by autoclaving at 15 psi (1210C) for 15 minutes and was cool to 47C,
and mixed well before pouring plates.
Cystine Lactose Electrolyte Deficient Medium (CLED)
CLED Agar is a valuable non-inhibitory growth medium used in the isolation and
differentiation of urinary organisms. Because CLED is electrolyte deficient, it prevents the
swarming of Proteus species. Cystine promotes the formation of cystine-dependent dwarf
colonies. Lactose fermenters produce yellow colonies on CLED agar; non-lactose fermenters
appear blue. It has a pH of approximately 7.3 (Wikipedia.org). CLED agar contains:
Table 1.3: CLED Agar Composition
Content
Concentration
20mg/l
Beef extract
3g/l
L-cystine
128mg/l
Peptone
Agar
4g/l
15g/l
Lactose
10g/l
Hydrolysed Cassin
4g/l
Tryptone
4.0g/l
pH
7.3
Preparation
36 grams of powder was weighed and added to 1 litre of cold de-ionized water and
autoclaved at 121C for 15 minutes. Cool to 470C and was mixed thoroughly before pouring
plates. Stored at 2-80C, preferably sealed in plastic bags to prevent loss of moisture.
Salmonella Shigella (S.S Agar)
Table 1.4: Salmonella Shigella Agar Composition
Content
Beef extract
5.00
Animal tissue
5.00
Sodium citrate
10.00
Sodium thiosulphate
8.50
Agar
15.00
Lactose
10.00
Ferric citrate
1.00
Brilliant green
Preparation
Concentration gm/ltr
0.00033
Neutral red
0.025
pH
7.00
8.50
63.0 grams of powder was weighed and added to one (1) litre of distilled water and allowed
to soak for 10 minutes, it was swirled to mix and then heat to the boiling with agitation to
dissolve the medium completely. It was allowed to cool to 47C and then mixed thoroughly
and poured into sterile petri plates. No autoclaving was needed for autoclaving may destroy
the selective of the medium.
MacConckey agar
The medium is best prepared from ready to use dehydrated powder, available from most
suppliers of culture media. The medium is usually used at a concentration of 5.2g in every
100ml distilled water. The various component of nutrient agar solution is shown in the table
below:
Table 1.5: MacConckey Agar Composition
Content
Concentration (g/l)
Peptone
20
Lactose
10
Bile salts
Sodium chloride
Neutral red
5
0.075
Agar
12
Ph
7.4
Preparation
52g of powder was suspended in 1 litre of distilled water. It was bring boil to dissolve
completely. Sterilized by autoclaving at 121 0C for 15 minutes. Poured into sterile petri plates
and then store in a cool dark place.
Table 1.5: Reagents for Glucose
Content
Concentration
3.2 U
72.6g
Glucose oxidase
Preparation
3.2 U
The reagent was already automated. Stored at 2 to 30C, this can be used up to the expiry
date printed on the pack of the container.
Table 1.6: Reagents for Glutamate Oxaloacetate (GOT), (aspartate aminotransferase)
Content
Pyruvate peroxidise
Peroxidise
Alanine sulfinate
Thiamine pyrophosphate
ketoglutarate
imidazole dihidrochloride
Buffer
Concentration
1.5 U
18 U
792g
1.49g
16.2g
16.4g
Preparation
The reagent was already prepared by the manufacturer. Stored at 2 to 30C, this is valid and
stable up to the expiry date given by the manufacturer.
Table 1.7: Reagents for Glutamate Pyruvate Transaminase (GPT), (Alanine amino transferase)
Content
Pyruvate peroxidise
Peroxidise
Alanine
Thiamine pyrophosphate
ketoglutarate
imidazole dihidrochloride
Buffer
Concentration
1.5 U
18 U
230g
1.49g
16.2g
16.4g
Preparation
The content is valid when stored at 2 to 30C and is used before the expiry date.
Concentration
4.7U
Tetrachlorophenoltetrabromosulfophthalein
(indicator)
20.4g
Buffer
Preparation
The reagents were already prepared by the manufacturer and normally stored at 2 to 30.
Under this condition, the tests can be used up to the expiry date printed on the pack or
container.
Table 1.12: Reagents for Creatinine
Content
Creatinine iminohydrolase
Composition
1.38U
N-methylhydantoinase
0.108U
0.439U
Sarcosine oxidase
0.475U
Peroxidase
2.29U
Ascorbate oxidase
0.285U
ATP
82.8g
Hydrochloride (indicator)
19.5g
Buffer
Preparation
The reagents were already prepared by manufacturer. The test can be used up to expiry date
printed on the pack or container when stored at 2 to 30C.
Concentration
0.84mg
2-methoxy-4niyrophenyldiazoniumtetrafluoroborate
10.4g
Preparation
The reagents were already prepared by manufacturer. The test can be used up to expiry date
printed on the pack or container when stored at 2 to 30C.
Concentration
394g
1005g
Magnesium
0.56g
Preparation
The reagents were already prepared by manufacturer. The test can be used up to expiry date
printed on the pack or container when stored at 2 to 30C.
Table 1.15: Reagents for Sodium ions
Content
Uranyl acetate
Magnesium acetate
Concentration
2.1Mm
20Mm
Sodium standard
150mEq/L
Preparation
The reagents were already prepared by manufacturer. Reagent set were all stored at room
temperature (15-300C). The reagents are stable until the expiration date indicated on the label.
Concentration
1.8Mm
10mM
NADH
0.40mM
MDH (porcine)
1,250U/L
PEPC (microbial)
200U/L
Sodium Oxamate
2.5mM
Buffer (pH)
7.0
0.1%
Preparation
Reconstitute CO2 reagent with the 6ml of CO2-free water. Mix by inversion 5-6 times. Do not
shake. Reconstituted reagents stored in the closed tightly stoppered bottle are stable for 1 day
at room temperature (18-260C) and 7 days refrigerated (2-80C).
CHAPTER THREE
METHODS/ANALYSIS OF ROUTINE WORK DONE IN THE VARIOUS
SECTION OF THE LABORATORY
USGH laboratory is divided into five (5) main units, these are:
3.0
Haematology unit
Medical microbiology/parasitology unit
Chemical pathology unit
Immunology unit
Transfusion unit
CHEMICAL PATHOLOGY UNIT
This is a unit of the laboratory that deals with the metabolism of the constituents of the blood.
Activities carried out in this unit include:
Carrying out liver profile test using the Reflotron machine or working reagents
Carrying out electrolyte test using the Reflotron for potassium and creatinine or working
reagents for all electrolytes
3.1
Factors regarding the collection of blood specimens that can affect the correctness of clinical
chemistry test results include:
- Incorrect venepuncture technique
- Haemolysis of red cells,
- Collection into the wrong container
- Instability of some chemical substances in whole blood, serum, and plasma
VENEPUNCTURE TECHNIQUE
The following precautions need to be followed when collecting venous blood in chemical
pathology:
*
Do not apply the tourniquet too tightly or for too long a period because this will cause
venous stasis leading to a concentration of substance in the blood such as
haemoglobin, plasma proteins, potassium and calcium.
Do not collect the blood from an arm into which an intravenous (IV) infusion is being
given.
If an anticoagulated specimen is required, add the correct amount of blood with the
anticoagulant by gently inverting the container several times.
AVODING HAEMOLYSIS
The haemolysis (rupture) of red cells can be a serious source of unreliable test results. If red
cells are haemolysed, substances from the cells are release into the serum or plasma leading
to a false increase in the concentration of analytes, e.g. potassium. Haemolysis also interferes
with many chemical reactions.
Haemolysis can be avoided by:
*
Checking that the syringe and needle are dry and that the barrel and plunger of the
syringe fit well.
Not withdrawing the blood too rapidly or moving the needle once it is in the vein.
Frothing of the blood must be avoided.
Removing the needle from the syringe before dispensing the blood into the specimen
container. Allow the blood to run gently down the inside wall of the container.
Adding the correct amount of blood to anticoagulant. Do not shake the blood but
gentle mix it with the anticoagulant.
Using clean dry tubes bottles for the collection of blood from which serum is required
and by allowing sufficient time for the blood to clot and clot retraction to take place.
Red cells are very easily haemolysed by rough use of an applicator stick to dislodge a
clot.
Centrifuging blood samples for a minimum period of time. Centrifuging for 5 minutes
at about 1000g is adequate to obtain serum or plasma.
Not storing whole blood samples in, or next to, the freezing compartment of a
refrigerator.
Potassium
Phosphate
Aspartate amino
Transferase (AST)
Lactate dehydrogenase
Sodium
Chloride
Carbon dioxide
Creatinine
Glucose
Urea
Urate
Some of the chemical changes which may occur in blood specimens within a few hours of
being collected include:
*
Diffusion of potassium and some enzymes through the red cell membrane into the
serum or plasma.
Diffusion of carbon dioxide off the surface of the blood, leading to a lowering in the
concentration of bicarbonate with a compensatory increase in plasma chloride.
Reduction or losses in the activity of certain enzymes, for example acid phosphatise.
Some of these changes can be prevented by separating the plasma or serum forms the red
cells as soon as possible (within 1 hour) after the blood has been collected. The blood should
not be refrigerated before the serum or plasma is separated because this can lead to falsely
raised potassium values. Glycolysis can be prevented by using fluoride-oxalate anticoagulant.
The decomposition of bilirubin can be avoided by protecting specimens from light.
To minimize any alteration in the concentration of substances due to the ingestion of food or
day time variation, most blood specimens are best collected at the beginning of the day before
a patient takes food.
3.1.1
ELECTROLYTES TEST
Electrolytes are substances that become ions in solution and acquire the capacity to conduct
electricity. The electrolytes that are measured include sodium, potassium, bicarbonate and
chloride using their various working reagents.
Sodium Test
Sodium is the major cation of extracellular fluid. It plays a central role in the maintenance of
the normal distribution of water and the osmotic pressure in the various fluid compartments.
The main source of body sodium is sodium chloride contained in ingested foods. Only about
one-third of the total bodys sodium is contained in the skeleton since most of it is contained
in the extracellular body fluids.
Principle
Sodium is precipitated as the triple salt sodium magnesium uranyl acetate; the excess
uranium then reacts with ferrocyanide to form a coloured complex whose absorbance varies
inversely as the concentration in the test specimen.
Procedure
Filtrate preparation
0.05ml of sample was added to all tubes and distilled water to the blank.
All the tubes were centrifuged at high speed (1,500G) for 10 minutes after which their
supernatant fluids were tested as describe below:
Colour development
The test tubes were labelled corresponding to the above filtrate tubes.
0.05ml of each supernatant was added to their respective tubes and mixed.
Calculations
Abs of Blank Abs of Sample
Abs of Blank Abs Standard
Reference Range
135 155mEq/L
Potassium Test
Potassium is the principle cation of the intracellular fluid. It is also an important constituent
of the extracellular fluid due to its influence on muscle activity. Its intracellular function
parallels that of its extracellular function, namely influencing acid-base balance and osmotic
pressure, including water retention.
Elevated potassium levels (hyperkalemia) are often associated with renal failure, dehydration
shock or adrenal insufficiency. Decrease potassium levels (hypokalemia) are associated with
malnutrition, negative nitrogen balance, gastrointestinal fluid losses and hyperactivity of the
adrenal cortex.
Principle
The amount of potassium is determined by using sodium tetraphenylboron in a specifically
prepared mixture to produce a colloidal suspension. The turbidity of which is proportional to
potassium concentration.
Procedure
0.01ml of samples was added to sample, standard reagent to the standard and mixed then
was allowed to stand at room temperature for 3 minutes.
Calculations
Abs of Unknown
Abs of Standard
Reference Range
3.4 5.3mEq/L
Chloride Test
Chloride, a major anion, is important in the maintenance of the cation/anion balance between
intra and extra-cellular fluids. This electrolyte is therefore essential to the control of proper
hydration, osmotic pressure, and acid/base equilibrium. Low serum chloride values are fond
with extensive burns, excessive vomiting, intestinal obstruction, nephritis, metabolic acidosis,
and in addisonian crisis. Elevated serum chloride value may be seen in dehydration,
hyperventilation, congestive heart valve, and prostatic or other types of urinary obstruction.
Principle
Hg(SCN)2 + 2Cl-
HgCl2 + 2SCN-
3SCN- + Fe3+
Chloride ions form a soluble, non-ionized compound, with mercuric ions and will displace
thiocyanate ions from non-ionized mercuric thiocyanate. The released thiocyanate ions react
with ferric ions to form a colour complex that absorbs light at 480nm. The intensity of the
colour produced is directly proportional to the chloride concentration.
Procedure
0.01ml of sample was added to sample tube, standard reagent to standard and distilled
water to blank and mixed.
Spectrophotometer was set at 480nm and was zero with reagent blank.
Calculations
Abs of Unknown
Abs of Standard
Reference Range
98 106mEq/L
3.1.2
UREA TEST
Urea is the major end product of protein nitrogen metabolism. It is synthesized in the liver
from ammonia, which is produced by amino acid determination. The determination of serum
urea renal function or increased tissue protein breakdown is associated with increased Urea
Nitrogen levels. Whereas liver damage or pregnancy are associated with decreased levels.
Principle
The Berthelot reaction has long been used for the measurement of urea and ammonia. The
present method is a modified Berthelot.
Urea + H2O
urease
2NH3 + CO2
2,2-Dicarboyindophenol
1.5ml of BUN Enzyme Reagent was pipette into labelled test tubes. It was allowed to
Deionized water was used as the sample for the Reagent Blank.
The tubes were incubated for five minute at 37 oC or ten minutes at room temperature
(18-30oC).
1.5ml of BUN Colour Developer was added and then mixed gently.
Tubes were incubated for five minute at 37oC or ten minutes at room temperature.
Reagent Blank was used to zero the spectrophotometer at 630nm.
Absorbencies of all tubes were red and recorded.
Calculations
Abs of Unknown
Abs of Standard
Reference Range
7-23mg/dL
3.1.3
CREATININE TEST
Creatinine reacts with picric acid in alkaline conditions to form a colour complex, which
absorbs at 510nm. The rate of formation of colour is proportional to the creatinine
concentration in the sample. In the endpoint method the difference in absorbance
measurements after colour formation yields a creatinine value corrected for interfering
substances.
Procedure
Equal volumes of creatinine picric acid reagent and creatinine buffer reagent were
combined and mixed well.
0.1ml of sample was transferred to its respective tube, standard reagent to the standard
and distilled water to reagent blank and mixed.
Calculations
The creatinine value of the unknown is determined by comparing its absorbance change with
that of a known standard.
Abs of Unknown
X Conc. of Std = Conc. of Creatinine
Abs of Standard
Reference Range
Male: 0.9-1.50mg/dl
Female: 0.7-1.37mg/kl
3.1.4
Urea samples were collected for the evaluation of renal function. The test is often used
together with the determination of Creatinine for differentiation between pre-renal and postrenal azotaemia on the basis of the urea/Creatinine ratio. These are products of
osmoregulation and are analyzed using the Reflotron. The reference ranges for urea and
Creatinine is 10 50mg/dl and 0.5 1.1mg/dl respectively.
Test Principle
After application to test strip, the sample flows into the reaction zone, in the case of blood
after separation of the erythrocytes from the plasma. The urea contained in the sample is
hydrolyzed to ammonium carbonate from which ammonia is expelled due to the alkaline
buffering. This leads to the partial colour change of a buffered indicator to green /blue, the
intensity of which is proportional to the urea concentration of the sample:
(NH2)2 CO + H2O
Urease
2NH3 + CO2
NH4+ + indicator (blue)
At a temperature of 37OC, the depth of colour formed is measured at 642nm and the urea
concentration displayed after about 190 seconds in mg/dl depending on how the instrument
has been set.
Sample Collection
Blood sample was collected in the Lithium Heparin tubes or Ethylene Diamine tetra acetic
tube.
Testing Procedure
Additional materials required are Reflotron instrument; Reflotron pipette and pipette tips or
capillary pipette and controls. The procedure used is as follows:
then closed.
The instrument displays urea/Creatinine to confirm that it has correctly read in the testspecific magnetic code. The display shows the number of seconds left before the result
was displayed. The concentration was calculated automatically from the readings taken
using a function and conversion factors that were entered in the instrument via the
magnetic strip on the underside of each test strip. The concentration was displayed in
mg/dl or mmol/l depending on whether the instrument has been set to show conventional
or S.I units.
The test strip used was then removed from the Reflotron and disposed of according to
laboratorys procedure.
3.1.5
The liver function test was carried out using the Reflotron. The machine determines the
concentration of particular enzyme and proteins in the liver by the use of strips. Liver
function test comprises of the Total Billurubin, glutamate oxaloacetate transaminase (GOT),
Glutamate Pyruvate transaminase (GPT), and Alkaline phosphate (ALP).
Glutamate Oxaloacetate Transaminase (GOT)
Glutamate oxaloacetate transaminase (aspartate aminotransferase) belongs to the group of
transaminase which catalyze the conversion of amino acids to the corresponding -keto acids
and vice versa by transfer of amino groups. Aspartate aminotransferase is found in many
tissues of the body.
Test Principle
After application to the test strip, the sample flows into the reaction zone, in the case of blood
after separation of the erythrocytes from the plasma. In the presence of GOT, -ketoglutarate
and alanine sulfinate are converted to Pyruvate oxidase, the resulting Pyruvate is cleaved into
acetyl phosphate, carbon dioxide and hydrogen peroxide. In the presence of POD the
hydrogen peroxide converts an indicator into its oxidised blue form:
-ketoglutarate + alanine sulfinate
Pyruvate + PO43- + O2 + H20 PyOD
H2O2 + indicator (red)
POD
GOT
At a temperature of 370C the formation of the dye was measured kinetically at 567nm as a
measure of the enzyme activity of GOT and the result was displayed after 124 seconds. The
result displayed for a temperature of 370C, 300C or 250C and in u/l.
Glutamate Pyruvate Transaminase
Glutamate pyruvate transaminase (alanine aminotransferase) belongs to the group of
transaminase which catalyzes the conversion of amino acids to the corresponding -keto
acids and vice versa by transfer of amino groups.
Test Principle
After application to the test strip, the sample flows into the reaction zone, in the case of blood
after separation of erythrocytes from the plasma. In the presence of GPT, -ketoglutarate and
alanine are converted to glutamate and pyruvate. In the second reaction step, catalyzed by
pyruvate oxidase, the resulting pyruvate was cleaved into acetyl phosphate, carbon dioxide
and hydrogen peroxide. In the presence of POD the hydrogen peroxide converts an indicator
into its oxidised blue form:
-ketoglutarate + alanine
GPT
POD
glutamate + pyruvate
PyOD
hydrolysis product o-cresolphthalein that is produced per unit of time under alkaline
conditions is directly proportional to alkaline phosphate activity:
O-cresolphthalein phosphate + methylglucamine
o-cresolphathlein + methylglucamine
phosphate.
Dye formation is determined kinetically at 37 0C as a measure of the enzyme activity of ALP.
The result is displayed after approximately 135 seconds in U/l.
Sample collection for LFT
Blood sample was collected into the lithium heparin tube or Ethylene diamine tetra acetic
tube.
Testing procedure for LFT (GOT, GPT, ALP)
Additional material required (not supplied): Reflotron instrument; Reflotron pipette and
pipette tips or capillary pipette, controls and usual laboratory equipment were used for
collecting blood. The procedure used is as follows:
When the display showed READY, the test strip was removed from the container.
The strip was unwrapped carefully so as not to bend it.
Using the Reflotron pipette, the sample material drawn into the pipette (avoiding bubbles)
and applied as a drop to the centre of the red application zone, taking care not to touch the
application zone with the pipette tip. Required volume of specimen
for
application
was 30nl
With the sliding cover or flap open, the test strip was placed on the guide within 15
specific
result
was
displayed.
ALP activity was calculated automatically from the readings taken using function and
conversion factors that are entered in the instrument via the magnetic strip on the
Component
Glutamate pyruvate transaminase(GPT)
Alkaline Phosphate(ALP)
Total Billurubin
Glutamine Oxaloacetate Transaminase (GOT)
3.2
Male (mg/dl)
Up to 41
Up to 270
0.5-1.0
Up to 40
Female (mg/dl)
Up to 32
Up to 240
0.5-1.0
Up to 33
HAEMATOLOGY UNIT
Haematology is unit in the main laboratory which is concerned with the study of blood, the
blood forming organs and blood diseases. The activities carried out in this unit include:
Cleaning the work bench with normal saline and methylated spirit
Running full blood count using stained film on microscope and counting chamber
Viewing the stained films under microscope for detection of malarial parasites
Carrying out genotype test using the cellulose acetate electrophoresis technique
The media room is where all the media used for culturing are prepared and stored. The most
common media used in the laboratory are; nutrient agar, chocolate agar, Cystine Lactose
Electrolyte Deficiency (CLED) agar, Salmonella Shigella Agar (SSA) and Mac Conkey agar
Activities carried out in this unit include:
Carrying out seminal fluid analysis SFA using the sperm quality analyser
Carrying out tests like the hepatitis b surface antigen and hepatitis c virus tests
respectively
Cleaning the work bench with jik and methylated spirit to disinfect it
HIV Counselling
ANALYSIS
3.0
IMMUNOLOGY UNIT
This is a unit of the laboratory where the immune system of HIV patients is assay and
counted using the BD FACSCount machine (CD4 Machine).
SPECIMEN COLLECTION AND STORAGE
FACSCount technique is designed to be used with human whole blood samples. Whole blood
is collected in a K3 EDTA vacutainer tube and stored no longer than 6 hours at room
temperature (20-250C).
Test procedure
All reagents were brought to ambient temperature
Procedure for preparing and running controls
Normal blood is needed to run controls. Blood sample must be collected in a K3 EDTA
vacutainer tube from a normal donor and run immediately or could be stored no longer than 6
hours at room temperature (20-250C).
Controls are prepared by adding normal blood, then fixative solution to the CD4 and CD8
reagents tubes followed by addition of control beads before reagent tubes are run. Controls
beads are packed in tube pairs similar to reagent tube pairs.
The normal blood donor was placed in the workstation. Two reagent tube pairs from foil bag
were removed. The foil bag was sealed and the unused reagent pairs were returned to the
refrigerator.
Pair two:
The pairs were vortex upside down for 5 seconds. The pairs were vortex upright for 5
seconds.
The reagent tubes was opened with coring station and closed to protect the reagents
from light.
The whole blood was mixed by inverting the tube five times.
50l of normal whole blood was pipette into each of the four reagent tubes. Each was
changed between tubes.
Tubes were incubated for 60 to 120 minutes at room temperature (20-250) in the dark.
After which tubes were uncapped and 50l of fixative solution was pipette into each
reagent tube. Tips were changed between tubes.
Reagent tubes were recapped with new caps and vortex upright for 5 seconds.
One pair of Zero/Low control beads and one pair of Medium/High control beads were
removed from the control kit and placed in the control area of the workstation.
The zero/low control beads pair was vortex for 6 seconds and reverse pipette of 50 l
of low control beads into the tube labelled low.
The medium/high control bead pair was vortex for 6 seconds and reverse pipette of
50l of medium control beads into the tube labelled medium.
Reverse pipette of 50l of the high control beads into the tube labelled high.
The controls were then run on the BD FACSCount Machine within 24 hours of adding
the control beads.
Patient samples were prepared by adding blood, then fixative solution to the CD4 reagent
tube.
The normal blood donor was placed in the workstation. One reagent tube pair was removed
for each patient. The foil bag was sealed and the unused reagent pairs were returned to the
refrigerator.
The tabs of one reagent tube pair was labelled with the patient laboratory number
The pairs were vortex upside down for 5 seconds. The pairs were vortex upright for 5
seconds.
The reagent tubes were opened with coring station. The workstation was closed to
protect the reagents from light.
The patient whole blood was mixed by inverting the tube five times
50l of whole blood was pipette into each two reagent tubes.
Then incubated for 60-120 minutes at room temperature (20-25 0) in the dark. The
reagent pairs were placed in the workstation and the cover was closed to protect the
reagents from the light.
The tubes were uncapped and 50l of fixative solution was pipette into each reagent
tube.
The reagent tubes were recapped with new caps and were vortex upright for 5
seconds.
The tubes were run on the FACSCount Machine within 48 hours of preparation.
Samples were stored at room temperature in the workstation until they were run on
the Machine. They were vortex upright for 5 seconds immediately before running.