EXIN Lightweight Building Panel

Technical specifications
Exploded view

Typical corner detail

m
35 m
Min.

EXIN

GLUE

FIBREGLASS
MESH
GLUE
PVC ANGLE

RENDER

Typical internal & external corner fixing

Typical expansion joint for internal & external corners

PVC ANGLE
INTERNAL LINING

150mm
FIBREGLASS

BACKING ROD
INTERNAL LINING
TOOLED EXPANSION
JOINT WITH
SEALANT
SEE TYPICAL
CORNER DETAIL

SYSTEM FASTENERS
150mm WIDE
JOINING MESH

NOTE: PVC PRIMED WITH


RESIN/PLASTER MIX
PRIOR TO RENDERING

SEE TYPICAL
CORNER DETAIL

TOOLED EXPANSION
JOINT WITH
SEALANT

SYSTEM FASTENERS

EXIN Lightweight Building Panel

View of wall in vertical section

Detail 1

SETTLEMENT SPACE,
Approx, 5mm

SEE DETAIL 1

PVC ANGLE
FIBREGLASS
EXIN
RENDER

EXIN
RENDER

SEE TYPICAL
EXPANSION JOINT

TIMBER STUD
OR STEEL FRAME

Detail 2

REINFORCED
CONCRETE SLAB
DETAIL 2

EXIN

REINFORCED
CONCRETE FOOTING

100mm MINIMUM

RENDER

FIBREGLASS
MESH
PVC ANGLE

NOTE: 75mm SLAB EDGE EXPOSURE ABOVE GROUND AS


PERIMETER BARRIER FOR TERMITE RISK MANAGEMENT.

EXIN Lightweight Building Panel

Technical specifications
Sill detail

Metal capped parapet

METAL CAPPING

SEALANT

PVC
ANGLE
RENDER

FIBREGLASS
MESH
EXIN

Head detail

Jamb detail

EXIN

EXIN
FIBREGLASS
MESH

FIBREGALSS
MESH

RENDER

RENDER

PVC ANGLE

SEALANT

PVC ANGLE

SEALANT

EXIN Lightweight Building Panel

Technical specifications
Brick/Exin panel junction

Typical flush eave section

IT IS ESSENTIAL THAT THE DISTANCE BETWEEN


TIMBER FRAME & FASCIA
REMAIN EVEN THROUGHOUT
i.e. 50mm typical

SEALANT
150mm WIDE
JOINING MESH
INTERNAL LINING

EXIN
RENDER
FIBREGLASS
PVC ANGLE
SEE TYPICAL
CORNER DETAIL
SEALANT
PVC FLASHING

MORTAR
BRICK

Typical Horizontal and Vertical Expansion Joints

Typical application: windows and other openings

NOTE: AN ALTERNATIVE IS TO
LOCATE CONTROL JOINTS ON
INT./EXT. CORNERS
BACKING ROD
SEALANT

PVC ANGLE

FIBREGLASS MESH
VERTICAL JOINT

HORIZONTAL JOINT

PVC BEADING
AFTER APPLICATION OF
FIBREGLASS MESH

NOTE:
1. Do not continue fibreglass reinforcing mesh
over expansion joints.
2. Flexible sealant continues through top coat.

Technical specifications
Fastener positioning at joints
RMAX WASHER
40

45
22.5

1200

22.5

1200

2500

max. 300

max. 300

min.12

max. 300 AROUND PERIMETER

max. 600 STUD CENTRES


JOINT

Bracing reinforcement

1 off 38mm
FLAT ROUND
WASHER & 1 OFF
12mm NUT

STEEL STRAP 0.8 X 30mm


SECTION WITH 4 OF
30 x 2.8mm
FLAT HEAD NAILS
AT EACH STUD
100

THE CONNECTION AT THE


TOP TO THE CEILING OR
ROOF FRAME MAY BE
IN ACCORDANCE WITH
AS 1684 - 1999 part 2, 3 and 4

20

ANCHOR ROD PLACED AT BOTH


ENDS OF EACH SECTION OF THE
BRACING WALL AND NOT MORE
THAN 2.4m CENTRES
-12mm DIAMETER
- FULL LENGTH MILD STEEL ROD

THE CONNECTION AT THE


BOTTOM TO THE FLOOR
FRAME OR CONCRETE SLAB
MAY BE IN ACCORDANCE
WITH THE REQUIREMENT of
AS 1684 - 1999 part 2, 3 and 4
2 OFF WASHERS

2 OFF NUTS

EXIN Lightweight Building Panel

Thermal insulation

Early fire hazard properties


(AS/NZS 1530.3 - 1999)

Panel thermal performance

From tests conducted by CSIRO (ref. 6) according to the AS/NZS


4859.1:2002, the following measured thermal performances are given
in table 5.
Table 5: R value of exinTEX or exinFLEX panel
Thickness (mm)

40

60

R value at 23C (m2.K/W)

1.10

1.60

Thermal conductivity at 23C (W/m2.K)


Thermal conductance at 23C (W/m2.K)

0.95

0.60

75

100

2.05

2.70

0.037

0.50

0.37

From tests conducted by AWTA, Division


of building Material - NATA Accreditation
# 1356, the following indices given in table 7
have been determined.
Table 7: Early fire hazard properties
of exinFLEX and exinTEX panels
Index

Result

Range

Spread of Flame Index

0 - 10

Ignitability Index

Heat Evolved Index

Smoke Developed Index

Exin wall system thermal performance

0 - 20

0 - 10

0 - 10

From calculations by thermal calculation code recognized by CSIRO,


the total R value for the complete Exin wall (see fig. 1) system
are given in table 6.

NOTE: The core material in Exin products is expanded polystyrene.


As with all other organic material, insulation products must
be considered combustible and to constitute a fire hazard
if improperly used or installed. The material contains a flame
retardant additive to inhibit accidental ignition from small fire sources.

Table 6: Total R value of Exin wall system

Exin Appraisals

Thickness (mm)

Total R value (m2.K/W)

60

1.95

40

1.50

75

2.35

100

3.10

Exin building panels have been subjected


to extensive testings and comply with relevant
Australian building practices. They have
also been technically assessed by CSIRO,
which has granted the CSIRO Building
Products and Systems Appraisals to Exin
Wall Panel (Technical Assessment 252).

Handling

EXIN
TYPICAL THICKNESS > 3mm
CHECK RENDER
APPLICATION
SPECIFICATION

TIMBER STUD - 90mm

Sheets should be stored under cover and laid


flat. Edges and corners are to be protected
at all times.

Warranty

Subject to warranty conditions, the Exin


building panel is warranted to be free
of defects in materials for a period of ten
years from the original purchase date.
PLASTER
BOARD - 10mm

COMPLETE WALL SYSTEM

Figure 1: Example of the complete Exin wall system

The information contained in this manual


is presented as a guide to users of Exin
products, and while to the best of Exins
knowledge it is correct and reliable,
no responsibility can be taken by the company
for the applications in which Exin products
may be selected or the way in which it is used.