150
R500SL82 MESH
CENTRALLY PLACED
DI
M ENSI
ON Y
2. R500SL82 mesh shall be provided in pit walls and floor slab centrally placed
for pit depths less than 1.8m. For pits deeper than 1.8m R500SL81 will
be provided.
3. Outlet pipes are to have rounded entrances.
ACCESS LID
FLOW
4. Pits deeper than 1.0m are to have step irons at 300mm spacing.
5. All pits to suit 1200mm dia pipes are to have R500SL82 mesh with 30mm
clear cover to bottom surface of suspended roof slab with 3 x D500N12
trimmer bars at 50mm centres around the access grate.
ACCESS LID
150
A
150
DIMENSION X
(b) For pits less than 1.8m deep provide R500SL82 mesh centrally
placed in floor and wall slabs.
150
PLAN
(c) For pit depths between 1.8m and 3.0m provide R500SL81
mesh centrally placed in floor and wall slabs.
7. Pits constructed to accommodate pipes larger than 1200mm dia. and having
depths greater than 3.0m are to have a special design.
PIPE DIA.
DIMENSION X
DIMENSION Y
ROOF SLAB
PRECAST CONCRETE
300-750mm
900mm
900mm
900mm
1050mm
1050mm
1050mm
1200mm
1200mm
LID SURROUND
(HTF OR LTF AS
SPECIFIED)
150
110
50
50
3 x D500N12 TRIMMER
=
=
=
=
=
=
CENTRALLY PLACED IN
ACCORDANCE WITH NOTE 6
150
BENCHING
PROVIDE 100mm
DIA. SUBSOIL DRAIN
(REFER TO NOTE 9)
DIMENSION Y
150
150
SECTION A-A
SCALES
RL: N/A
DESIGN
DRAWING
DATE
AR, CG
DATE
DESIGN FILES
CHECKED
DRAWING FILES
U:\TS\Technical Support\Design
DATE
MANAGER TECHNICAL SUPPORT
19/06/2014
DATE
SENIOR DESIGN ENGINEER
19/06/2014
NOT TO SCALE
29/05/2014
No.
DATE
1.
29/05/2014
APP'D
DETAILS OF AMENDMENTS
CG
AMENDED
2.
19/06/2014
CG
AMENDED
ORIGINAL SIZE A1
APPROVED
DRAWING TITLE
JOB
SHEET No.
DATE
5 cm
DUBBO
CITY COUNCIL
TECHNICAL SERVICES DIVISION
STORMWATER
JUNCTION PIT
OF
STANDARD DRAWING
1
SHEETS
PLAN NO.
STD 1271