Académique Documents
Professionnel Documents
Culture Documents
Rev A
Doherty Combiner
b
Description
The X3DC19E2S is a low profile, high performance Doherty Combiner
in a new easy to use, manufacturing friendly surface mount package.
The X3DC19E2S is designed particularly for Doherty Amplifier
applications, where tightly controlled phase and amplitude imbalance as
well as low insertion loss are required for maximum and low power
condition. It can be used in high power applications up to 200 watts.
Features:
1930 - 1990 MHz
High Power
Low Amp Imbalance
Very Low Loss
Production Friendly
Tape and Reel
Lead Free
Parts have been subjected to rigorous qualification testing and they are
manufactured using materials with coefficients of thermal expansion
(CTE) compatible with common substrates such as FR4, G-10, RF-35,
RO4350 and polyimide. Produced with 6 of 6 RoHS compliant tin
immersion finish
Electrical Specifications **
Phase
Return
Insertion
Amplitude
Operating
Frequency
Imbalance
[1]
[1]
[1]
Loss
Loss
Imbalance
Temp.
[1]
MHz
dB Min
dB Max
dB Max
Degrees
1930 1990
20
0.15
0.12
90 3.0
-55 to +95
Return
[2]
Loss
Insertion
[2]
Loss
Port
[3]
Extension
dB Min
dB Max
Degrees
Avg. CW
Watts
C/Watt
20
0.20
200
27
[4]
Power
JC
Mechanical Outline
Available on Tape
and Reel for Pick and
Place Manufacturing.
USA/Canada:
Toll Free:
Europe:
(315) 432-8909
(800) 411-6596
+44 2392-232392
Model X3DC19E2S
Rev A
RF input
RF output
Main Amp
90
50
90
35
NC
90
Peak Amp
Anaren Doherty
Combiner
Port Extension
50
Pin 1
Pin 4
50
90
50
90
Pin 3
Pin 2
35
50
Pin 1
Combining Port
Pin 2
Not Used
Pin 3
Peak Amp Port
Pin 4
Main Amp Port
There are inevitably short lines associating with input ports in some high frequency band parts. The length of the
short line is specified as electrical length at center frequency and noted as port extension in this datasheet. The
designer should take this length into the consideration to optimize the offset line length.
USA/Canada:
Toll Free:
Europe:
(315) 432-8909
(800) 411-6596
+44 2392-232392
Model X3DC19E2S
Rev A
0
-55C
25C
95C
-10
R e t u rn L o s s (d B )
R e tu rn Lo s s (d B )
-10
-20
-30
-40
-50
1930
-55C
25C
95C
-20
-30
-40
1940
1950
1960
1970
Frequency (MHz)
1980
-50
1930
1990
1950
1960
1970
Frequency (MHz)
1980
1990
-55C
25C
95C
-0.02
1940
-55C
25C
95C
-0.05
In s e rt io n L o s s (d B )
In s e rtio n L o s s (d B )
-0.04
-0.06
-0.08
-0.1
-0.12
-0.1
-0.15
-0.2
-0.25
-0.14
1930
1940
1950
1960
1970
Frequency (MHz)
1980
1990
-0.3
1930
1940
Available on Tape
and Reel for Pick and
Place Manufacturing.
1950
1960
1970
Frequency (MHz)
USA/Canada:
Toll Free:
Europe:
1980
1990
(315) 432-8909
(800) 411-6596
+44 2392-232392
Model X3DC19E2S
Rev A
Typical Performance (-55C, 25C, 95C & 125C): 1930 1990 MHz
0.2
-55C
25C
95C
-86
-55C
25C
95C
0.15
0.1
A m p lit u d e B a la n c e (d e g )
P ha s e B alanc e (de g)
-88
-90
-92
0.05
0
-0.05
-0.1
-0.15
-94
1930
1940
USA/Canada:
Toll Free:
Europe:
1950
1960
1970
Frequency (MHz)
(315) 432-8909
(800) 411-6596
+44 2392-232392
1980
1990
-0.2
1930
1940
1950
1960
1970
Frequency (MHz)
1980
1990
Model X3DC19E2S
Rev A
Under the maximum power condition, the symmetrical Doherty architecture requires main amplifier and peak amplifier to
work at full capacity with the optimum termination (50 ). The two amplifiers should deliver RF power of equal
magnitude and 90 degree phase difference. Doherty combiner functions as a coherent power combiner and supplies the
90 degree phase compensation. The following specification is defined with 50 port impedance at three ports for this
condition.
Parameter
Definition
Return Loss
Insertion Loss
Phase Imbalance
Amplitude Imbalance
Mathematical Representation
S11
20log
(S
10log
Phase
2
13
2
+ S14
(20log S
14
20log S13 )
2
Under low power condition, the Doherty operation turns off peak amplifier and requires main amplifier to be terminated
with double of the optimum impedance (100 ). With the peak port open, Doherty combiner servers as an impedance
transformer transforming 50 at combining port to 100 at main amplifier port. The following specification is defined
under the port impedance condition of Port 1 (Combining Port) 50 , Port 4 (Main Amp Port) 100 and Port 3 (Peak Amp
Port) open.
Parameter
Definition
Mathematical Representation
Return Loss
20log
S11
Insertion Loss
20log
S 41
Available on Tape
and Reel for Pick and
Place Manufacturing.
USA/Canada:
Toll Free:
Europe:
(315) 432-8909
(800) 411-6596
+44 2392-232392
Model X3DC19E2S
Rev A
.059
[1.50]
.157
[4.00]
.069
[1.75]
.453
[11.50]
.591
[15.00]
.059
[1.50]
.228
[5.80]
.315
[8.00]
XX XX
.094
[2.40]
.945
[24.00]
USA/Canada:
Toll Free:
Europe:
(315) 432-8909
(800) 411-6596
+44 2392-232392