PRODUCT DATA
FEATURES
Media postfilters (optional) provide enhanced filtration.
Available in five sizes to fit most ducts; adapts to
airflow from either side.
Capacity varies from 1000 cfm (2040 m3/hr) to 2000 cfm
(3400 m3/hr), depending on size.
Solid state power supply is self-regulating and
maintains peak efficiency during a wide range of cell
dirt loading conditions.
Low pressure drop.
Optional W8600F Air Cleaner Monitor indicates air
cleaner performance, reminds homeowner when filter
and cell maintenance are due and when to check the
system.
Optional wireless W8600A AIRWATCH LCD indicator
provides reminder when air cleaner electronic cells
need washing, when media postfilters need replacing,
when UV lamps need replacing and when humidifier
pad needs replacing.
Galvanized cabinet protects against rust.
APPLICATION
The F300 Electronic Air Cleaner is mounted in the return air
duct of a forced air heating, cooling, or ventilating system. It
captures a significant amount of the airborne particles 0.3
micron and larger from air circulated through it.
Contents
Application/Features..........................................................
Specifications/Ordering Information ..................................
Installation ........................................................................
Operation ..........................................................................
Checkout ..........................................................................
Service .............................................................................
Replacement Parts/Exploded View ...................................
1
2
8
11
11
12
17
68-0240EF-5
SPECIFICATIONS
IMPORTANT
The specifications given in this publication do not
include normal manufacturing tolerances. Therefore,
this unit may not exactly match the listed specifications. This product is tested and calibrated under
closely controlled conditions, and some minor differences in performance can be expected if those conditions are changed.
in.
mm
No.
Cells
16 x 25
406 x 635
0.4
0.2
Model:
20 x 25
508 x 635
0.4
0.2
16 x 20
406 x 508
0.4
0.2
20 x 20
508 x 508
0.4
0.2
20 x
12-1/2
508 x 318
0.4
0.2
Electrical Ratings:
Voltage and Frequency: Models available for 120V, 60 Hz.,
240V, 60Hz. 120V models can be converted in the field to
240V, 60 Hz or 220/240V, 50 Hz with the 203365A
Conversion Kit.
Power Consumption:
One cell models: 22 W maximum
Two cell models: 36 W maximum.
Current Draw: See Table 1.
Ionizer Voltage: 8150 Vdc.
Collector Voltage: 4075 Vdc.
120V
220/240V
Fractional Efficiency:
Efficiency ratings are based on American Society of Heating,
Refrigerating and Air-Conditioning Engineers Standard
52.2-1999. Efficiency ranges are defined for small particles,
E1 =.3 to 1.0 micron; medium particles, E2 = 1.0 to 3.0
microns; and large particles, E3 = 3.0 to 10.0 microns.
Table 2. Fractional Efficiency With and Without Postfilter.
With postfilter
Without postfilter
ORDERING INFORMATION
When purchasing replacement and modernization products from your TRADELINE wholesaler or distributor, refer to the
TRADELINE Catalog or price sheets for complete ordering number.
If you have additional questions, need further information, or would like to comment on our products or services, please write or
phone:
1. Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory).
2. Honeywell Customer Care
1885 Douglas Drive North
Minneapolis, Minnesota 55422-4386
In CanadaHoneywell Limited/Honeywell Limite, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9.
International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France,
Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
68-0240EF-5
.20
(49.7)
20 x 25 in.
(508 x 635 mm)
16 x 25 in.
(406 x 635 mm)
.15
(37.3)
20 x 20 in.
(508 x 508 mm)
20 x 12-1/2 in.
(508 x 318 mm)
.10
(24.9)
.05
(12.4)
4
1
400
(680)
500
(850)
3
600
(1020)
700
(1190)
800
(1360)
.25
(62.2)
16 x 20 in.
(406 x 508 mm)
900
(1530)
1000
(1700)
1100
(1870)
1200
(2040)
1300
(2210)
1400
(2380)
1500
(2550)
1600
(2720)
1700
(2890)
1800
(3060)
1900
(3230)
2000
(3400)
.35
(87.2)
.30
(74.7)
16 x 20 in.
(406 x 508 mm)
.25
(62.2)
20 x 20 in.
(508 x 508 mm)
20 x 25 in.
(508 x 635 mm)
16 x 25 in.
(406 x 635 mm)
.20
(49.7)
.15
(37.3)
.10
(24.9)
.05
(12.4)
20 x 12-1/2 in.
(508 x 318 mm)
0
400
(680)
500
(850)
600
(1020)
700
(1190)
800
(1360)
900
(1530)
1000
(1700)
1100
(1870)
1200
(2040)
1300
(2210)
1400
(2380)
1500
(2550)
1600
(2720)
1700
(2890)
1800
(3060)
1900
(3230)
2000
(3400)
MINIMUM RECOMMENDED cfm FOR 20 x 12-1/2 in. (508 x 318 mm) MODEL.
M13654
Temperature Ratings:
Weight:
See Table 3.
Mounting:
Dimensions:
See Fig. 2.
Approvals:
68-0240EF-5
Accessories:
Repair Parts:
16 x 25 in.
(406 x 635 mm)
20 x 12-1/2 in.
(508 x 318 mm)
20x 20 in.
(508x 508 mm)
20 x 25 in.
(508 x 635 mm)
lb
kg
lb
kg
lb
kg
lb
kg
lb
kg
Electronic Cell
(each)
2.25
2.7
7-1/2
3.4
6-3/16
2.8
7-1/2
3.4
Shipping Weight
30
13.6
33
15.0
25
11.3
33
15.0
38
17.2
Installed Weight
(Cells included)
26
11.6
28
12.7
21
9.5
29
13.2
33
15.0
68-0240EF-5
3
8 (162)
DIM. E
(SEE TABLE)
DIM. B
(SEE TABLE)
DIM. A
(SEE TABLE)
7
5
8
(22) 8
(16)
3
6
4
(172)
IN.
F50F SIZE
MM
16 X 25
16 X 20
20 X 25
20 X 20
20 X 12 1/2
406 X 635
406 X 508
508 X 635
508 X 508
508 X 318
DIM. A
DIM. B
IN.
MM
14 7/16
367
367
14 7/16
18 7/16
18 7/16
18 7/16
7
8
(22)
468
468
468
IN.
16 3/16
16 3/16
20 3/16
20 3/16
20 3/16
DIM. C
IN.
MM
MM
411
411
23 1/4
18 1/4
513
513
513
23 1/4
18 1/4
10 7/8
591
457
591
457
276
DIM. D
DIM. E
IN.
MM
IN.
25 1/2
20 1/2
648
521
648
2 3/4
2 3/4
25 1/2
20 1/2
13 1/8
521
333
2 3/4
2 3/4
3 5/8
MM
70
70
70
70
92
M2872A
IMPORTANT
Do not mount in the discharge air duct.
Application
68-0240EF-5
Choose Location
NOTE: The volume of water that is discharged from an atomizing humidifier can overload the air cleaner, resulting
in hard water salts being deposited as dust in the living space.
68-0240EF-5
WARNING
A
B
M19777
Transitions
Transitions are needed when the duct is a different size than
the air cleaner cabinet. Gradual transitions reduce air
turbulence and increase efficiency. Limit expansion to no more
than 20 degrees or about 4 in. per running foot (100 mm per
300 linear mm) on each side of a transition fitting.
See Fig. 4.
RETURN
AIR DUCT
TRANSITION FITTING
ELECTRONIC AIR CLEANER CABINET
M5626A
Turning Vanes
If the air cleaner is installed close to an elbow or angle fitting,
install turning vanes inside the angle to distribute airflow more
evenly across the face of the cell. See Fig. 5.
68-0240EF-5
Offsets
If the duct connection to the furnace in a side installation allows
less than 7 in. (178 mm) for mounting the air cleaner cabinet,
add an offset to the elbow. See Fig. 5.
AIR CLEANE
AT LEAST
7 in.
[178 mm]
INSTALLATION
When Installing this Product...
1.
2.
3.
4.
WARNING
68-0240EF-5
M20804
DOWNSTREAM
AIRFLOW
CELL KEY
CELL KEY
SCREW
CELL
KEY
PREFILTER GUIDES
M5639
ALTERNATE
HOLES FOR
KEY
4.
5.
Turn the key around and place it over the opposite holes.
The tab on the bottom fits into the larger hole, and the
screw fits into the smaller hole. Make sure the arrow on
the key points in the direction of the air flow (downstream).
Tighten the screw into the new hole.
Insert the electronic cell. The ionizer section will now be
on the air-entering (upstream) side of the cabinet.
LOCKING
PLIERS
M20815
Seal Joints
! Seal all joints in the return air system between the air
cleaner and the furnace to prevent dust from entering the
clean airstream. Use optional air cleaner cabinet gasket kit
(part no. 32002109-001), mastic or foil tape.
ROTATE 90
DEGREES
FOLD TAB
TO LOCK
HANDLE
IN PLACE
M6047A
68-0240EF-5
! Insert the electronic cells with the gray contact board toward
the power supply and the airflow arrow pointing
downstream. If the cell does not slide easily into the cabinet,
check the orientation of the cell key.
! Insert the metal mesh prefilters on the upstream side of the
cabinet in the guide provided.
! Insert the media postfilters (on select models) on the
downstream side of the cabinet in the guide provided.
! Replace the access door. Insert the tab on the bottom of the
door into the slot in the cabinet, then swing it closed and
press into place. The door must be firmly in place or the air
cleaner will not operate.
Complete Wiring
WARNING
BLACK COLLECTOR
RED IONIZER
TEST
BUTTON
RED
BLACK
CONTACT
BOARD
P3
BLACK
BLACK
P4
POWER
SUPPLY
J5
J4
J8
3
BROWN
J3
P2
P1
J1
BLACK
ORANGE
GRAY
VIOLET
W4 W2 W1 W3
68-0240EF-5
10
GREEN
BLACK
BLACK
BLACK
WHITE
BLACK
1 INTERLOCK SWITCH.
M23413
1.
2.
3.
4.
5.
6.
7.
8.
9.
OPERATION
Large particles (lint, hair) are caught by the prefilter. As the
dirty air passes through the intense high voltage electric field
surrounding the ionizer wires, all particles are given an
electrical charge.
The air then moves through the collector part of the cell where
alternate parallel plates are charged positively and negatively,
creating a uniform electrostatic field. The charged particles are
attracted to and collect on the plates that have the opposite
electrical charge.
The air then passes through media postfilters, removing
additional particles from the air stream. The air leaving the air
cleaner has fewer particles. Each time the air circulates
through the electronic air cleaner, more particles are removed.
CHECKOUT
Inspect the Installation
Make sure:
Turning vanes and transitions, as needed, are correctly
installed.
Sheet metal joints between air cleaner and furnace are
sealed.
All sheet metal connections are complete.
Original furnace filter has been removed and the blower
compartment cleaned.
If atomizing humidifier is installed upstream from the air
cleaner, a disposable furnace filter is installed between the
humidifier and the air cleaner.
Outside air, if used, is mixed with return air or heated, as
necessary, before it can reach the air cleaner.
Airflow arrows on the electronic cell point downstream.
Metal mesh prefilter is on the upstream side and media
postfilter is on downstream side of the cell.
Cell handle faces outward.
Electronic cell and prefilter are clean and dry.
W8600F wiring connections are correctly made.
3
M20806
WIRING
COMPARTMENT
ELECTRONIC
AIR CLEANER
2
BLACK
BROWN
L1 (HOT)
L2
M5707
11
68-0240EF-5
SERVICE
CAUTION
Sharp Edges.
Can cause personal injury.
Carefully handle the cell(s) or wear protective gloves to
avoid cuts from the sharp metal edges.
IMPORTANT
Vacuum the prefilter or brush or soak it in a tub. Do
not wash the prefilter in the dishwasher or car wash.
Automatic Dishwasher
CAUTION
Burn Hazard.
Can cause personal injury.
Allow cells to cool completely in dishwasher at end of
wash cycle or wear protective gloves to avoid burns.
Hot water can accumulate in the tubes supporting
collector plates; tip cells so tubes drain.
IMPORTANT
Check the dishwasher owner's manual. Some
manufacturers do not recommend washing electronic cells
in their dishwashers.
If the dishwasher has upper and lower arms, position the
cells carefully to allow good water circulation.
Be careful to avoid damaging the cells when placing them in
the dishwasher. Broken ionizer wires or bent collector plates
are not included in the warranty.
Very dirty cells, especially from tobacco or cooking smoke,
can discolor the plastic parts and the lining of some
dishwashers. This discoloration is not harmful. To minimize
it, wash the cells more frequently or try a different brand of
detergent.
Do not allow the dishwasher to run through the dry
cycle. This bakes on any contaminants not removed during
the wash cycle and reduces air cleaner efficiency.
1.
Put the cells on the lower rack of the dishwasher with the
airflow arrow pointing up. It may be necessary to remove
the upper rack. Do not block water flow to the upper arm.
2.
68-0240EF-5
12
3.
4.
Using regular dishwasher detergent, allow the dishwasher to run through the complete wash and rinse
cycle. Do not use the dry cycle. To avoid burns, let the
cells cool completely before removing, or wear protective
gloves when removing the cells. Remember that water
may be trapped inside the cells. Tip the cells so the
tubes can drain.
Wipe ionizer wires and contact board on the end of the
cell using thumb and forefinger with a small, damp cloth.
Inspect the dishwasher. Rerun wash and/or rinse cycle
with the dishwasher empty if there is dirt or residue from
washing the cells. If dirt or residue seems excessive,
wash cells more often or try a different detergent.
7.
CAUTION
Hazardous Chemical.
Can cause personal injury.
Do not splash detergent solution in eyes. Wear rubber
gloves to avoid prolonged detergent contact with skin.
Keep detergent and solution out of reach of children.
NOTE: Always wash the cells first, then the prefilters, to keep
heavy prefilter lint from getting caught in the cells.
1.
3.
HIGH VELOCITY
DETERGENT SPRAY
Dissolve about 3/4 cup of automatic dishwasher detergent per cell in enough hot water to cover the cells. If
detergent does not dissolve readily, or forms a scum on
the water, try another brand, or use softened water
After detergent has completely dissolved, place cells in
the container and let soak for 15 to 20 minutes. Agitate
up and down a few times and remove. See Fig. 13.
STEAM
WEAR GLOVES
TO PROTECT
HANDS FROM
DETERGENT
SOLUTION.
M20831
M922A
6.
Next, wash the prefilters the same way. Empty and rinse
the wash container.
Rinse the cells and prefilters with a hard spray of very
hot water; rinse the tub clean, then fill the tub with clean
hot water and soak for 5 to 15 minutes. Rinse until the
water draining from the cells and prefilters no longer
feels slippery.
Soak cells and prefilters in a final clear water rinse for
ten minutes.
13
Inspect the cells for broken ionizer wires and bent collector plates. Repair as necessary or take to a
Honeywell Authorized Air Cleaner Repair Station.
Slide the prefilters into the upstream prefilter guides.
Slide in the air cleaner cells so the airflow arrow points
downstream and the handles faces outward.
Firmly close the access door.
Turn on the air cleaner. If the cells and prefilters are wet,
the neon light may not come on and you may hear
arcing. If the arcing is annoying, simply turn off the air
cleaner for two to three hours or until the cells are dry.
68-0240EF-5
COLLECTOR
TERMINAL
IONIZER
TERMINAL
COLLECTOR
TERMINAL
CAUTION
SPRING
CONNECTORS
PRESS
DOWN
EYELETS
IONIZER
WIRE
IONIZER
WIRE
NEEDLENOSE
PLIERS
1
M1540B
68-0240EF-5
14
a.
b.
c.
d.
WARNING
2.
REMOVE POWER BOX FROM AIR CLEANER AND REMOVE THE COVER.
3
2
4
M20807
Fig. 17. Remove power box from air cleaner and remove cover.
15
68-0240EF-5
P3
J5 SHUNT
IN OZONE
REDUCTION
POSITION
P4
E5 E6
J5
J4
J5 IN
NORMAL
POSITION
E4 E3
E2
E1
P2
J1
J3
P1
M15099
Fig. 18. Move J5 shorting bar to reduce ozone production about 20 to 25 percent.
68-0240EF-5
16
Description
16 x 20 in.
(406 x 508 mm)
16 x 25 in.
20 x 12-1/2 in.
(406 x 635 mm) (508 x 318mm)
20 x 20 in.
20 x 25 in.
(508 x 508 mm) (508 x 635 mm)
32007528-003
32007528-003
N/A
32007528-002
32007528-002
137980A (1)
137980A (1)
137980A (1)
137980A (1)
137980A (1)
Electronic Cell
FC37A1114 (2)
FC37A1130 (2)
FC37A1064 (1)
FC37A1049 (2)
FC37A1064 (2)
Cell Handle
137266 (2)
137266 (2)
137266 (1)
137266 (2)
137266 (1)
209989 (2)
203368 (2)
203369 (1)
203370 (2)
203369(2)
Cell Key
136518 (1)
136518 (1)
136518 (1)
136518 (1)
136518 (1)
208417S (1)
208419Dd
208418H (1)
208417R (1)
240V, 60 Hzc
8
Switch
208419Bb
203321 (1)
203321 (1)
203321 (1)
203321 (1)
203321 (1)
208045J (1)
208045G(1)
208045G
208045G (1)
208045G (1)
N/Ac
N/Ac
N/A
N/Ac
N/Ac
4074ETG (1)
4074ETG (1)
4074ETG (1)
4074ETG (1)
4074ETG (1)
203329B (1)
203329B (1)
N/A
N/A
203329B (1)
203329A (1)
203329A (1)
N/A
203329A (1)
203329A (1)
17 Line Cord
4074ETD (1)
4074ETD (1)
4074ETD (1)
4074ETD (1)
4074ETD (1)
19 Neon Assembly
4074EYS (1)
4074EYS (1)
4074EYS (1)
4074EYS (1)
4074EYS (1)
4074ETH (1)
4074ETH (1)
4074ETH (1)
4074ETH (1)
4074EZB (1)
4074EZB (1)
N/A
4074EZB (1)
4074EZB (1)
4074EHG
4074EHG
4074EHG
4074EHG
4074EHG
50000293-001
50000293-002
50000293-004
50000293-003
50000293-004
b
Series Two compatible with W8600F.
c
Use 203365A Conversion Kit for charging 120V, 60 Hz model to 240V, 60 Hz.
d
Change from brown cover to white cover as a running change. Use original cover for color match.
17
68-0240EF-5
10
14
20
17
13
12
11
19
8
22
21
4
3
2
1
M18846D
Fig. 19. F300 Electronic Air Cleaner (2-cell model shown) exploded view of components.
Part Numbers are keyed to Parts List.
68-0240EF-5
18
16 x 20 in.
(406 x 508 mm)
16 x 25 in.
(406 x 635 mm)
20 x 12-1/2 in.
(508 x 318)
20 x 20 in.
(508 x 508 mm)
20 x 25 in.
(508 x 635 mm)
Air Cleaner
Cabinet Gasket
Kit
32002109-001
32002109-001
32002109-001
32002109-001
32002109-001
Ionizer Wires
(Multiples of 5)
136434BA
136434BA
136434AA
136434AA
136434AA
Premier White
AIRWATCH
Indicator
W8600A1007
W8600A1007
W8600A1007
W8600A1007
W8600A1007
Premier White
Air Cleaner
Monitor
W8600F1014
W8600F1014
W8600F1014
W8600F1014
W8600F1014
240V Conversion
Kit
203365A
203365A
N/A
203365A
203365A
19
68-0240EF-5
INSTALLATION DATE:
YEAR
M19779
68-0240EF-5
20
MAKE SURE ELECTRONIC CELLS ARE CLEAN, DRY AND PROPERLY INSTALLED.
MAKE SURE METAL PREFILTERS ARE POSITIONED ON THE SIDE WHERE
AIR ENTERS THE AIR CLEANER, AND THAT POST-FILTERS (IF ANY) ARE
POSITIONED ON THE SIDE WHERE AIR LEAVES THE AIR CLEANER.
TURN THE POWER SWITCH ON THE AIR CLEANER ON, AND TURN THE
HVAC FAN ON.
OFF
ON
YES
NO
TURN OFF AIR CLEANER POWER
SWITCH. REMOVE THE DOOR AND
CHECK THAT THE CONTACTS ON
THE INSIDE OF THE TEST BUTTON
ARE OK.
NO
YES
AIR CLEANER IS
FUNCTIONING PROPERLY.
NO
REPLACE OR
REPAIR CELLS.
ON
WARNING
NO
FIX WIRING.
YES
REPLACE AIR CLEANER
POWER SUPPLY.
NO
SHORT
CELLS OK.
REPLACE AIR
CLEANER
POWER SUPPLY.
THIS AIR CLEANER PRODUCES A TRACE LEVEL OF OZONE AS A BY-PRODUCT OF NORMAL OPERATION, WHICH IS WELL UNDER THE
LIMIT PRESCRIBED BY THE U.S. F.D.A. PLEASE REFER TO YOUR OWNERS MANUAL FOR FURTHER INFORMATION. FOR A REPLACEMENT
OWNERS MANUAL, CALL 1-800-468-1502 OR VISIT http://yourhome.honeywell.com
WARNING
INCORRECT CONVERSION TO MEDIA AIR CLEANER CAN CAUSE FIRE HAZARD.
WHEN CONVERTING AN ELECTRONIC AIR CLEANER TO A MEDIA AIR CLEANER
THE POWER SUPPLY MUST BE REMOVED OR PERMANENTLY DISABLED.
M13656
21
68-0240EF-5
35 Dynamic Drive
customer.honeywell.com
U.S. Registered Trademark
2006 Honeywell International Inc.
68-0240EF-5 M.S. Rev. 06-06
CARACTRISTIQUES
Post-filtres fibres qui permettent dobtenir une
filtration amliore.
Offert en cinq tailles qui conviennent la plupart des
gaines dair : sadapte lcoulement dair dun ct
ou de lautre.
Dbit variant de 1 000 pi3/min (2 040 m3/h)
2 000 pi3/min (3 400 m3/h) selon la taille.
Bloc dalimentation semi-conducteurs autorgulateur qui maintient lefficacit de pointe du filtre
air peu importe le degr dencrassement des cellules.
Perte de charge faible.
Moniteur de filtre air W8600F offert en option
renseigne sur le rendement du filtre, rappelle au
propritaire de nettoyer les cellules, de laver le
pr-filtre et de vrifier le systme.
Indicateur sans fil cristaux liquides W8600A
AIRWATCHmd offert en option rappelle au propritaire
quand laver les cellules. Il rappelle galement quand
remplacer les lampes UV et les crans vaporateurs de
lhumidificateur.
APPLICATION
Le filtre air lectronique F300 sinstalle dans la gaine de
reprise dair dans un systme de chauffage, de
refroidissement ou de ventilation air puls. Il retient un trs
grand nombre de particules en suspension dans lair, de 0,3
micron et plus, qui le traversent.
1
1
2
5
7
11
11
12
17
68-0240EF-5
FICHE TECHNIQUE
IMPORTANT
Les caractristiques techniques indiques dans la
prsente publication ne comprennent pas les
tolrances normales de fabrication. Par consquent,
il se peut que l'appareil ne corresponde pas
exactement aux caractristiques indiques. De
mme, le produit a t mis l'essai et talonn dans
des conditions entirement contrles et on peut
s'attendre de lgres diffrences de
fonctionnement si ces conditions sont modifies.
Modle :
F300E Filtre air lectronique avec botier, porte daccs,
bloc dalimentation semi-conducteurs, deux cellules
lectroniques, deux prfiltres en mailles mtalliques et
deux post-filtres fibres.
F300A,B Filtre air lectronique avec botier, porte daccs,
bloc dalimentation semi-conducteurs, deux cellules
lectroniques et deux prfiltres en mailles mtalliques.
Caractristiques lectriques nominales :
Tension et frquence : 120 V, 60 Hz., 240V, 120Hz. Peut tre
converti en clientle en un modle de 240 V, 60 Hz ou de
220/240 V, 50 Hz au moyen de lensemble 203365A.
Consommation dnergie : 36 W maximum.
Appel de courant : Voir le Tableau 1.
Tension de lionisateur : 8 150 V c.c.
Tension du collecteur : 4 075 V c.c.
po
Nbre de
cellules
120 V
220/240 V
406 x 635
16 x 25
0,4
0,2
508 x 635
20 x 25
0,4
0,2
406 x 508
16 x 20
0,4
0,2
508 x 508
20 x 20
0,4
0,2
508 x 318
20 x 12 1/2
0,4
0,2
Dcomposition de lefficacit :
Les caractristiques nominales de lefficacit proviennent de
la norme American Society of Heating, Refrigierating and AirConditioning Engineers Standard 52.2-1999. Les
pourcentages defficacit sont dfinis pour les petites
particules, E1 = 0,3 1 micron; particules moyennes,
E2 = 1,0 3,0 microns; et les grosses particules,
E3 = 3,0 10 microns.
Tableau 2. Dcomposition de lefficacit.
Avec post-filtres fibres :
3
E1 = jusqu 81 % 492 pi /
min.
POUR COMMANDER
Au moment d'acheter des produits de modernisation ou de remplacement auprs de votre grossiste ou distributeur
TRADELINE, consultez le catalogue TRADELINE ou les tarifs pour obtenir le numro de pice.
Prire d'adresser toute question additionnelle, demande d'information ou commentaires sur les produits et services par crit ou
par tlphone :
1. Au bureau des ventes de produits de rgulation et d'automatisation Honeywell de votre localit (consulter les pages
blanches de l'annuaire tlphonique).
2. Honeywell Customer Care
1885 Douglas Drive North
Minneapolis, Minnesota 55422-4386
Au Canada : Honeywell Limited-Honeywell Limite, 35 Dynamic Drive, Scarborough (Ontario) M1V 4Z9. Points de vente et de
service dans toutes les grandes villes du monde. Usines en Allemagne, en Australie, au Canada, en Espagne, aux tats-Unis,
en Finlande, en France, au Japon, au Mexique, aux Pays-Bas, au Royaume-Uni et Taiwan.
68-0240EF-5
SANS POST-FILTRES
62.2
(.25)
406 x 508 mm
(16 x 20 in.)
49.7
(.20)
508 x 635 mm
(20 x 25 in.)
406 x 635 mm
(16 x 25 in.)
37.3
(.15)
508 x 508 mm
(20 x 20 in.)
508 x 318 mm
(20 x 12-1/2 in.)
24.9
(.10)
4
1
680
(400)
12.4
(.05)
2
850
(500)
3
1020
(600)
1190
(700)
1360
(800)
1530
(900)
1700
(1000)
1870
(1100)
2040
(1200)
2210
(1300)
2380
(1400)
2550
(1500)
2720
(1600)
2890
(1700)
3060
(1800)
1900
(3230)
3400
(2000)
CAPACIT EN m3 /h (pi3/min)
AVEC POST-FILTRES
87.2
(.35)
508 x 318 mm
(20 x 12-1/2 in.)
62.2
(.25)
508 x 508 mm
(20 x 20 in.)
508 x 635 mm
(20 x 25 in.)
406 x 635 mm
(16 x 25 in.)
49.7
(.20)
37.3
(.15)
24.9
(.10)
12.4
(.05)
74.7
(.30)
406 x 508 mm
(16 x 20 in.)
0
680
(400)
850
(500)
1020
(600)
1190
(700)
1360
(800)
1530
(900)
1700
(1000)
1870
(1100)
2040
(1200)
2210
(1300)
2380
(1400)
2550
(1500)
2720
(1600)
2890
(1700)
3060
(1800)
1900
(3230)
3400
(2000)
CAPACIT EN m3 /h (pi3/min)
1
MF13654
68-0240EF-5
406 x 635 mm
(16 x 25 po)
lb
kg
lb
508 x 318
(20 x 12-1/2)
kg
lb
508 x 635 mm
(20 x 25 po)
kg
lb
508 x 508 mm
(20 x 20 po)
kg
lb
2,25
2,7
3.4
7-1/2
2,8
6 3/16
3,4
lexpdition
13,6
30
15,0
33
11.3
25
15,0
33
17,2
38
11,6
26
12,7
28
9.5
21
13,2
29
15,0
33
162
(6-3/8)
DIM. E
(VOIR TABLEAU)
DIM. B
(VOIR
TABLEAU)
DIM. A
(VOIR
TABLEAU)
22
(7/8) 16
(5/8)
172
(6-3/4)
TAILLE F300E
PO
MM
406 X 635
508 X 635
406 X 508
508 X 508
22
(7/8)
16 X 25
20 X 25
16 X 20
20 X 20
DIM. A
MM
PO
367
468
367
468
14-7/16
18-7/16
14-7/16
18-7/16
DIM. D
DIM. B
MM
PO
DIM. C
MM
PO
MM
PO
411
513
411
513
591
591
457
457
648
648
521
521
25-1/2
25-1/2
20-1/2
20-1/2
16-3/16
20-3/16
16-3/16
20-3/16
23-1/4
23-1/4
18-1/4
18-1/4
DIM. E
MM
PO
70
70
70
70
2-3/4
2-3/4
2-3/4
2-3/4
68-0240EF-5
MF19776
PLANIFICATION DE LINSTALLATION
Application
Applications humidificateur
Un humidificateur vaporation peut tre install en amont du
filtre air. Un humidificateur atomiseur devrait tre install en
aval du filtre air mme si des sdiments deau dure
sintroduiront dans les pices sous forme de poussire et se
dposeront. Dans le cas dun humidificateur atomiseur en
amont du filtre air :
1. Monter lhumidificateur le plus loin possible en amont du
filtre air.
2. Installer un filtre jetable standard pour appareil de chauffage entre lhumidificateur et le filtre air pour retenir les
gouttes deau et les sdiments deau dure.
3. Nettoyer le filtre air frquemment pour empcher
laccumulation de sdiments deau dure.
REMARQUE : Le volume deau qui passe dans lhumidificateur atomiseur peut surcharger le filtre air. Par
consquent, les sdiments deau dure pourraient sintroduire dans les pices sous forme
de poussire.
Choix de lemplacement
Choisir un emplacement permettant de faire facilement la
vrification et le nettoyage normaux du filtre. Prvoir un
dgagement dau moins 330 mm (13 po) lavant de la porte
daccs pour retirer le prfiltre et la cellule. Prvoir
suffisamment despace au-dessus du bloc dalimentation pour
faire la maintenance sans avoir enlever les tuyaux, les
gaines ou dautres composants du systme de chauffage.
Le filtre doit tre install un endroit o la temprature se situe
entre 4 C et 52 C (40 F 125 F).
IMPORTANT :
La lampe UV peut endommager les post-filtres
fibres. viter de placer la lampe UV en aval du F300
lendroit o la lampe UV claire le post-filtre.
68-0240EF-5
AVERTISSEMENT
quipement lourd.
Peut causer des blessures ou endommager
lquipement.
Ne pas installer le filtre air de sorte que la porte
daccs soit dirige vers le plancher. Si la porte daccs
fait face au plancher, le verrou pourrait se dtacher et
la cellule, le prfiltre et le post-filtre pourraient tomber
brusquement.
A
B
M19777
Raccords de transition
Des raccords de transition sont ncessaires lorsque les
dimensions de la gaine et du botier du filtre air sont
diffrentes. Les raccords de transition rduisent la turbulence
et augmentent lefficacit. Lexpansion maximale doit tre de
20 degrs (environ 100 mm par 300 mm linaires [4 po par
pied linaire]) de chaque ct du raccord de transition. Voir la
Fig. 4.
ELECTR
ONIC
AIR CLEANE
AU MOINS
178 mm
[7 po]
EXPANSION DE 20 DEGRS DE
CHAQUE CT, PAR RACCORD
(100 mm par 300 mm linaires)
(4 po par pied linaire).
GAINE DE
REPRISE DAIR
INSTALLATION
RACCORD
DE TRANSITION
BOTIER DU FILTRE AIR LECTRONIQUE
RACCORD DE
DRIVATION
MOINS DE
178 mm
[7 po]
MF5626A
1.
2.
Dflecteurs
3.
4.
Raccords de drivation
Si le raccord entre la gaine et lappareil dans le cas dune
installation sur le ct offre un dgagement infrieur 178 mm
(7 po) pour le botier du filtre air, ajouter un raccord de
drivation au coude. Voir la Fig. 5.
AVERTISSEMENT
Risque de choc lectrique.
Peut causer un choc lectrique ou endommager
lquipement.
Ne pas brancher lappareil avant davoir termin
linstallation.
68-0240EF-5
68-0240EF-5
M20804
EN AVAL
CLAVETTE
DE LA
CELLULE
DBIT
D'AIR
VIS POUR
LA CLAVETTE
CLAVETTE DE
LA CELLULE
DFLECTEURS
AUTRES
TROUS POUR
LA CLAVETTE
GUIDES DU PRFILTRE
MF5639
PINCE-TAU
3.
MF20815
4.
5.
TOURNER
90 DEGRS
PLIER LA LANGUETTE
POUR VERROUILLER
LA POIGNE EN PLACE
MF6047A
68-0240EF-5
Terminer le raccordement
AVERTISSEMENT
Risque de choc lectrique
Peut causer des blessures.
Ne pas utiliser de cordon de rallonge.
COLLECTEUR NOIR
FIL DIONISATION ROUGE
ROUGE
BOUTON
DESSAI
NOIR
LANGUETTE
DE CONTACT
P3
NOIR
NOIR
P4
ALIMENTATION
J5
J4
J8
3
BRUN
P2
P1
J1
J3
ORANGE
NOIR
GRIS
VIOLET
W4 W2 W1 W3
VERT
NOIR
NOIR
NOIR
BLANC
NOIR
1 INTERRUPTEUR DASSERVISSEMENT.
68-0240EF-5
10
3.
4.
5.
6.
7.
8.
9.
FONCTIONNEMENT
RETRAIT DU COUVERCLE
DU BLOC DALIMENTATION.
VRIFICATION
Vrifier linstallation
Vrifier ce qui suit :
les dflecteurs et les raccords de transition sont bien
installs;
les joints en tle entre le filtre air et lappareil de chauffage
sont scells;
tous les raccords en tle ont t poss;
le filtre original a t retir et le compartiment du ventilateur
a t nettoy;
si un humidificateur atomiseur est install en amont du filtre
air, un filtre jetable pour appareil de chauffage est install
entre lhumidificateur et le filtre air;
lair extrieur, sil y a lieu, est mlang avec lair repris ou
chauff au besoin avant datteindre le filtre air;
les flches indiquant le sens de lcoulement dair sur la
cellule lectronique pointent vers laval;
le prfiltre en mailles mtalliques est du ct amont de la
cellule lectronique et le post-filtre fibres est du ct aval
de la cellule lectronique;
la poigne de la cellule fait face vers lextrieur;
la cellule lectronique et le prfiltre sont propres et secs;
les raccordements du W8600F (sil y a lieu) sont bien faits.
3
MF20806
COMPARTIMENT
DE CBLAGE
FILTRE AIR
LECTRONIQUE
2
NOIR
BRUN
L1 (SOUS TENSION)
1
L2
11
68-0240EF-5
MAINTENANCE
MISE EN GARDE
Rebords coupants.
Peut causer des blessures.
Manipuler les cellules avec soin ou porter des gants de
protection pour viter les coupures sur les rebords de
mtal coupants.
MISE EN GARDE
Danger de brlure.
Peut causer des blessures.
Laisser refroidir compltement les cellules dans le
lave-vaisselle aprs le cycle de lavage ou porter des
gants de caoutchouc pour viter les brlures. De leau
chaude peut saccumuler dans les tubes qui
soutiennent les plaques collectrices. Incliner les
cellules pour permettre leau de scouler.
68-0240EF-5
12
IMPORTANT
Consulter le manuel de lutilisateur fourni avec le
lave-vaisselle. Des fabricants dconseillent de nettoyer les cellules dans leur appareil.
Si le lave-vaisselle comporte un bras de gicleur
suprieur et infrieur, placer les cellules de manire
permettre une bonne circulation de leau.
Prendre garde dendommager les cellules en les
plaant dans le lave-vaisselle. Les fils ionisants briss
et les plaques collectrices plies ne sont pas couverts
par la garantie.
Des cellules trs sales cause de la fume de
cuisson ou de tabac peuvent dcolorer les pices en
plastique et les parois de certains lave-vaisselle. Il ny
a aucun risque pour la sant. Laver les cellules plus
frquemment ou essayer une autre marque de
dtergent pour rduire au minimum la dcoloration.
NE PAS faire fonctionner le lave-vaisselle au cycle
de schage car cela provoquerait lincrustation des
contaminants qui nont pas t enlevs durant le
cycle de lavage et rduirait par le fait mme lefficacit du filtre.
1.
3.
4.
Utiliser le dtergent qui convient le mieux votre lavevaisselle. Faire fonctionner le lave-vaisselle pendant un
cycle de lavage et de rinage complet. Ne pas utiliser le
cycle de schage. Afin dviter les brlures, laisser
refroidir compltement les cellules avant de les sortir, ou
porter des gants de protection. Il peut y avoir de leau
lintrieur des plaques des cellules. Incliner les cellules
pour permettre leau de scouler.
Prendre un chiffon propre et, avec le pouce et lindex,
essuyer les fils ionisants et le panneau de contacts
lextrmit de la cellule.
Vrifier le lave-vaisselle. Sil y a des rsidus et de la
salet dans le lave-vaisselle une fois le filtre enlev, le
faire fonctionner de nouveau pendant un cycle de lavage
ou de rinage. Sil semble y avoir trop de salet ou de
rsidus, nettoyer les cellules plus souvent ou employer
un autre dtergent.
MISE EN GARDE
1.
3.
STEAM
M20831
2.
3.
4.
5.
MF922A
6.
7.
13
68-0240EF-5
BORNE DU
COLLECTEUR
BORNE DE
L'IONISATEUR
BORNE DU
COLLECTEUR
MISE EN GARDE
CONNECTEURS
LASTIQUES
APPUYER
VERS LE BAS
OEILLETS
1
FIL
IONISANT
FIL
IONISANT
PINCE BEC DE
CANARD
MF1540B
AVERTISSEMENT
Risque de choc lectrique
Peut causer des blessures
Seul un technicien qualifi devrait effectuer les tapes
suivantes.
68-0240EF-5
14
2.
3
2
4
MF20807
15
68-0240EF-5
P3
J5 SHUNT
IN OZONE
REDUCTION
POSITION
P4
E5 E6
J5
J4
J5 IN
NORMAL
POSITION
E4 E3
E2
E1
J1
J3
P2
P1
M15099
Fig. 18. Dplacer la tige de coupe-circuit J5 pour rduire la production dozone denviron 20 25 %.
68-0240EF-5
16
Description
406 x 635 mm
(16 x 25 po)
203306AB (1)
203306AB (1)
203306AB (1)
203306AB (1)
Cellule lectronique
FC37A1114 (2)
FC37A1130 (2)
FC37A1049 (2)
FC37A1064 (2)
Poigne de cellule
137266 (2)
137266 (2)
137266 (1)
137266 (1)
Prfiltre
209989 (2)
203371 (2)
203373 (2)
203372 (2)
Clavette de cellule
136518 (1)
136518 (1)
136518 (1)
136518 (1)
208418J (1)
208417S (1)
208418H (1)
208417R (1)
no
32007528-003
32007528-002
508 x 635 mm
(20 x 25 po)
Poste daccs
32007528-003
508 x 508 mm
(20 x 20 po)
406 x 508 mm
(16 x 20 po)
32007528-002
Interrupteur
203321 (1)
203321 (1)
203321 (1)
203321 (1)
Couvercle de bloc
dalimentation et tiquette
32004930-002
32004930-001
32004930-002
32004930-001
10
208414G (1)
208414B (1)
208414B (1)
208414A (1)
11
Patte et interrupteur de
verrouillage
4074ETG (1)
4074ETG (1)
4074ETG (1)
4074ETG (1)
12
Bornier du W8600
13
203329B (1)
203329B (1)
203329C (1)
14
203329A (1)
203329A (1)
203329A (1)
15
Plaque de sparation
203331 (1)
203331 (1)
203331 (1)
203331 (1)
16
Serre-cble
203852 (1)
203852 (1)
203852 (1)
203852 (1)
17
Cordon secteur
4074ETD (1)
4074ETD (1)
4074ETD (1)
4074ETD (1)
18
Bouchon
203847 (1)
203847 (1)
203847 (1)
203847 (1)
19
Lampe au non
4074EYS (1)
4074EYS (1)
4074EYS (1)
4074EYS (1)
20
4074ETH (1)
4074ETH (1)
4074ETH (1)
4074ETH (1)
21
Post-filtre fibres
50000293-001
50000293-002
50000293-003
50000293-004
22
4074EHG
4074EHG
4074EHG
4074EHG
Utiliser une trousse de conversion 203365A pour convertir le bloc dalimentation 120 V, 60 Hz en bloc dalimentation 240 V, 60 Hz
ou 220/1240 V, 50 Hz.
17
68-0240EF-5
10
14
20
17
13
12
11
19
8
22
21
4
3
2
1
M18846D
Fig. 19. Composants du filtre air lectronique (illustr : modle deux cellules).
68-0240EF-5
18
406 X 508 mm
(16 x 20 po)
406 x 635 mm
(16 x 25 po)
508 x 508 mm
(20 x 20 po)
508 x 635 mm
(20 x 25 po)
32002109-001
32002109-001
32002109-001
32002109-001
136434BA
136434BA
136434BA
136434BA
Vis de fixation
136375 (6)
136375 (6)
136375 (6)
136375 (6)
W8600F1008
W8600F1008
W8600F1008
W8600F1008
W8600F1007
W8600F1007
W8600F1007
W8600F1007
W8600F1014
W8600F1014
W8600F1014
W8600F1014
S.O.
FXC37A1247 (2)
S.O.
FC37A1239 (2)
203365A
203365A
203365A
203365A
19
68-0240EF-5
DATE D'INSTALLATION:
ANNE
MF19779
68-0240EF-5
20
LARRT
NON
OUI
EN MARCHE
AVERTISSEMENT
NON
REMPLACER OU
RPARER
LES CELLULES
REMPLACER
LES CELLULES
NON
OUI
OUI
REMPLACER LENSEMBLE
LAMPE/INTERRUPTEUR.
OUI
VRIFIER SI LA TENSION
DALIMENTATION EST BONNE AUX
BORNES P1 ET P2 DE LA CARTE
DALIMENTATION..
NON
CORRIGER LE RACCORDEMENT..
OUI
REMPLACER LE BLOC
DALIMENTATION DU FILTRE AIR..
AUCUN
COURT-CIRCUIT
LES CELLULES
FONCTIONNEMENT
CORRECTEMENT.
REMPLACER LE BLOC
DALIMENTATION
DU FILTRE AIR.
CE FILTRE AIR PRODUIT DE LOZONE EN QUANTIT NGLIGEABLE COMME SOUS-PRODUIT DU FONCTIONNEMENT NORMAL
DE LAPPAREIL; LES QUANTITS PRODUITES SONT LARGEMENT INFRIEURES AUX LIMITES PRVUES PAR LAGENCE FDRALE
AMRICAINE POUR LE CONTRLE DES PRODUITS ALIMENTAIRES ET PHARMACEUTIQUES (FDA). PRIRE DE CONSULTER
LE GUIDE DE LUTILISATEUR POUR OBTENIR DAUTRES RENSEIGNEMENTS. POUR OBTENIR UN GUIDE DE LUTILISATEUR
POUR LE REMPLACEMENT, COMPOSER LE 1-800-468-1502 OU SE RENDRE LADRESSE http://yourhome.honeywell.com
AVERTISSEMENT
LA CONVERSION INCORRECTE DU FILTRE AIR LECTRONIQUE EN FILTRE AIR FIBRES PEUT
POSER UN RISQUE DINCENDIE. LORS DE LA CONVERSION DUN FILTRE AIR LECTRONIQUE EN FILTRE
AIR FIBRES, LE BLOC DALIMENTATION DOIT TRE RETIR OU MIS HORS SERVICE DE FAON PERMANENTE.
21
MF13656
68-0240EF-5
Honeywell
Offrez votre famille un air ambiant de
meilleure qualit en faisant appel aux
solutions Honeywell. Confort et
tranquillit desprit seront au rendez-vous.
Systme de traitement dair aux ultraviolets
liminez les microbes contenus dans lair et
empchez les spores de moisissures de crotre
sur les serpentins de refroidissement
Filtre air pour toute la maison
Emprisonnez une bonne partie des particules
contenues dans lair
Humidificateur pour toute la maison
Humidifiez lair trop sec, maintenez lhumidit
ambiante pour rduire les effets
ngatifs sur la sant
Systme de rgulation par zones
Rglez la temprature ambiante par zones pour
plus de commodit et un confort accru
changeur dair PerfectWindow
Arez la maison pour que lair soit plus sain
tout en rduisant la perte dnergie
Thermostat programmable
conomisez jusqu 30 % du cot annuel de
lnergie grce ce thermostat dinstallation facile*
* selon lemplacement gographique et lutilisation
customer.honeywell.com
Marque de commerce dpose aux .-U.
2006 Honeywell International Inc. Tous droits rservs
68-0240EF-5 M.S. Rev. 06-06