Vous êtes sur la page 1sur 100

I-FOR INFORMATION

AWC-APPROVED WITH COMMENTS

Approval not required

Valid for construction. Return back the document


corrected within two weeks

X A-APPROVED

R-REJECTED

Valid for construction

Not valid for construction. Return back the document


corrected within one week

RESPONSIBLE & DATE

Alberto Robles

ARM (14.07.2014)

IMPORTANT NOTE: documentation approval does not relieve the manufacturer of its
responsibility for the adequancy and suitability of the information, equipments and/or
materials included in it for the function that is intended

Memoria de Ingeniera
SISTEMA DE PROTECCION CONTRA INCENDIOS

RESERVA FRIA ETEN

DOCUMENTO: RFE-SPCI-001
REV.
FECHA
0
19/05/2014
1
15/06/2014
2
30/06/2014

DESCRIPCION
Para revisin-aprobacin
Para revisin-aprobacin
Para revisin-aprobacin

ELABORADO POR
INICIALES
FS
FS
FS

FIRMA

APROBADO POR
INICIALES

FIRMA


REF: RFE-SPCI-001

RESERVA FRIA ETEN


15/06/2014

CONTENIDO
1.

GENERALIDADES

2.

INTRODUCCION

3.

DESCRIPCION DE LOS SISTEMAS


3.1.

CASA DE BOMBAS CONTRA INCENDIO

3.1.1.

CRITERIOS DE DISEO

3.1.2.

OPERACION DEL SISTEMA

3.2.

SISTEMAS DE ENFRIAMIENTO

3.2.1.

CRITERIOS DE DISEO

3.2.2.

OPERACION DEL SISTEMA

3.3.

SISTEMA DE ESPUMA EN TANQUES DE COMBUSTIBLE

3.3.1.

CRITERIOS DE DISEO

3.3.2.

OPERACION DEL SISTEMA

3.4.

ALIMENTACION A SISTEMA DE ENFRIAMIENTO DE PARED DE TANQUES DE


COMBUSTIBLE (APORTADO POR OTROS)

3.4.1.

OPERACION DEL SISTEMA

4. CALCULOS HIDRAULICOS


REF: RFE-SPCI-001

RESERVA FRIA ETEN


15/06/2014

SISTEMA DE PROTECCION CONTRA INCENDIOS


1. GENERALIDADES
El presente documento contiene la descripcin tcnica del diseo de la primera parte del
SISTEMA DE PROTECCIN CONTRA INCENDIOS, a instalarse en la Central de
Generacin Elctrica RESERVA FRIA ETEN, ubicada en la provincia de Chiclayo-Per.
El diseo se ha realizado en base a las recomendaciones de los fabricantes de los equipos y
haciendo uso de los siguientes cdigos de la National Fire Protection Association (NFPA):

NFPA 11: Standard for Low-Expansion Foam


NFPA 13: Installation of Sprinkler Systems
NFPA 15: Water Spray Fixed Systems for Fire Protection
NFPA 20: Standard for Stationary Pumps for Fire Protection
NFPA 24: Installation of Private Fire Service Mains and Their Appurtenances
NFPA 30: Flammable and Combustible Liquids Code
NFPA 70: National Electrical Code, 2002
NFPA 72: National Fire Alarm Code, 2002
NFPA 101: Life Safety Code, 2002

NFPA 170: Fire Safety Symbols, 2002


NFPA 850: Recommended Practice for Fire Protection for Electric Generating Plants and
High Voltage Direct Current Converter Stations

Lo expuesto a continuacin, analiza todos los aspectos tcnicos que se encuentran claramente
especificados en los planos para revisin-aprobacin y en el presente documento. As, para el
proceso de instalacin se deber consultar toda la informacin tcnica relativa a este proyecto y
hacer uso de las recomendaciones de la NFPA, con el objeto de garantizar que no existan
conflictos con el diseo original.
2. INTRODUCCION
La primera parte del Sistema de Proteccin Contra Incendios se ha diseado pensando en una
proteccin adecuada de la planta de Generacin Elctrica RESERVA FRIA ETEN. Esta parte
incluye los siguientes los siguientes sub-sistemas:

Casas de Bombas Contra Incendios


Sistema de Rociadores Automticos en Casa de Bombas
Sistema de Enfriamiento en Techos de Tanques de Combustible
Sistema de Espuma en Tanques de Combustible
Supervisin de los sistemas anteriores a travs del Sistema de Alarma y Deteccin de
Incendios
Alimentacin a sistema de enfriamiento de pared de tanques de combustible


REF: RFE-SPCI-001

3.

DESCRIPCION DE LOS SISTEMAS

3.1.

CASA DE BOMBAS CONTRA INCENDIOS

RESERVA FRIA ETEN


15/06/2014

El sistema de casa de bombas contra incendio se ha diseado en base a las recomendaciones


de la NFPA 20, Standard for the Installation of Stationary Pumps for Fire Protection, NFPA 70,
Nacional Electrical Code, y especificaciones tcnicas de de los fabricantes de los equipos.
De forma general, una casa de bombas contra incendio est bsicamente conformada por un una
bomba principal, cuya finalidad es el combate de incendios, una bomba jockey para mantener
presurizado el sistema ante cualquier prdida de presin que pueda presentarse, controladores
automticos, lneas piloto para monitoreo de la presin, soportera, tuberas y dems elementos
requeridos para su adecuada operacin.
Para proteccin de la casa de bombas ante una eventualidad de incendio, se instalar rociadores
automticos en toda su rea, de acuerdo a las recomendaciones de la NFPA 13: Installation of
Sprinkler Systems. El sistema de rociadores de la casa de bombas ser supervisado por el
sistema de alarma y deteccin de incendios.
3.1.1.

CRITERIOS DE DISEO

El dimensionamiento de la bomba contra incendios principal garantizar el abastecimiento mnimo


requerido por cada uno de los sistemas de proteccin contra incendios a instalarse, de acuerdo a
los clculos hidrulicos y considerando un gasto simultneo de:

Enfriamiento lateral de uno de los tanques diesel (1,324.4GPM) + sistema de espuma de


uno de los tanques diesel (408.9GPM)+ un hidrante (500GPM)

El dimensionamiento se realiz utilizando el recorrido de la tubera subterrnea hidrulicamente


ms desfavorable, esto es considerando la posibilidad de que existirn tramos de la red aislados
por mantenimiento (los clculos hidrulicos muestran el tramo considerado como crtico).
Tambin se presentan los clculos hidrulicos con toda la red subterrnea operativa.
La capacidad nominal del equipo de bombeo ser de 2000GPM@125PSI. La presin esttica
de la red ser mantenida por una bomba jockey con capacidad para 25GPM@130PSI.
Como se puede observar en las curvas de las bombas adjuntas al presente documento,
ninguna de las bombas contra incendio y jockey superarn los 100mca (141.99PSI) a vlvula
cerrada. De esta manera, la tubera subterrnea de HDPE estar no se someter a niveles de
presiones fuera de su rango de operacin normal.
La casa de bombas contra incendios estar situada junto a los tanques de abastecimiento de
agua 32A y 32B, como se indica en plano de planta adjunto.


REF: RFE-SPCI-001

RESERVA FRIA ETEN


15/06/2014

El agua para el sistema contra incendio ser abastecida por los tanques 32A y 32B.
La casa de bombas contra incendio estar constituida por los siguientes equipos y accesorios:
Bomba diesel
Una bomba centrfuga tipo horizontal, accionada por un motor diesel cuyo tanque de
combustible de 270 galones, ser instalado al interior de la casa de bombas.
Las caractersticas de la bomba principal son las siguientes:

Tipo: Horizontal actuada por motor diesel

Caudal: 2000 gpm

Presin: 125 psi

Potencia: 240HP

Controlador: Basado en microprocesador

Tipo de cubierta de controlador: NEMA 4

Aprobacin: Underwriters Laboratories

Certificacin: Factory Mutual

La alimentacin elctrica al tablero de control de la bomba principal ser de 220VAC,


60Hz con una lnea de tierra y una proteccin de 15A. El cable a utilizarse ser tipo
THWN 12 AWG.
Banco de bateras
La energa para el arranque del motor diesel ser proveda por dos bancos de bateras
de 12VDC. Estas bateras permanecern cargadas a travs del controlador de la bomba
principal.
Medidor de caudal
Con el propsito de realizar pruebas de flujo y de eficiencia de la bomba, se instalar un
medidor de caudal de acuerdo a NFPA 20. Se instalar un solo medidor de caudal con
arreglo mostrado en planos, el cual permitir seleccionar la bomba a utilizar.
Lnea de alivio
Para proteger la instalacin de casa de bombas en caso de emergencia por sobre
presin debida a una revolucin del motor, se instalar una lnea que aliviar


REF: RFE-SPCI-001

RESERVA FRIA ETEN


15/06/2014

incrementos de presin en caso de sobre revolucin del motor diesel. Se instalar una
relief valve - pilot operated con retorno a la cisterna segn se indica en los planos.
Refrigeracin del motor
El sistema de enfriamiento del motor funcionar con el agua de impulsin. Esta ser
derivada desde la descarga de la bomba hasta el circuito secundario del sistema de
refrigeracin. El agua usada ser evacuada hacia el exterior de la sala de bombas.
Evacuacin de gases
Los gases de combustin del motor diesel sern evacuados hacia el exterior de la casa
de bombas utilizando una tubera de acero al carbono. La conexin de esta tubera con
el silenciador y el conector flexible del motor diesel sern ajustadas en obra.
Ventilacin
El aire necesario a la combustin del motor y la evacuacin del calor producido durante
el funcionamiento de la bomba sern asegurados por un doble juego de rejillas, previstas
en la obra civil de la casa de bombas.
Bomba elctrica
Una bomba centrfuga tipo horizontal, accionada por un motor elctrico.
Las caractersticas de la bomba principal son las siguientes:

Tipo: Horizontal actuada por motor elctrico

Caudal: 2000 gpm

Presin: 125 psi

Potencia: 200HP

Tipo de motor: ODP

Controlador: Basado en microprocesador

Tipo de cubierta de controlador: NEMA 4

Aprobacin: Underwriters Laboratories

Certificacin: Factory Mutual

La alimentacin elctrica al tablero de control de la bomba principal ser de 480VAC,


60Hz con una lnea de tierra y una proteccin de 280A y que garantice una corriente a


REF: RFE-SPCI-001

RESERVA FRIA ETEN


15/06/2014

rotor bloqueado de 1450A durante 8 a 20 segundos. El cable a utilizarse ser tipo THWN
90C, 4/0.
Medidor de caudal
Con el propsito de realizar pruebas de flujo y de eficiencia de la bomba, se instalar un
medidor de caudal de acuerdo a NFPA 20. Se instalar un solo medidor de caudal con
arreglo mostrado en planos, el cual permitir seleccionar la bomba a utilizar.
Lnea de recirculacin
Se instalar una vlvula de recirculacin de operacin automtica de , cuya funcin es
prevenir incrementos de temperatura en la bomba cuando entra en operacin a vlvula
cerrada.
Ventilacin
El aire necesario a la combustin del motor y la evacuacin del calor producido durante
el funcionamiento de la bomba sern asegurados por un doble juego de rejillas, previstas
en la obra civil de la casa de bombas.
Bomba jockey
La bomba jockey ser del tipo centrfuga multietapas, accionada por un motor elctrico
trifsico de 480 VAC, 60 Hz.
Las caractersticas de la bomba jockey son las siguientes:

Caudal: 25 gpm

Presin: 130 psi

Capacidad de motor: 3HP 3/60/480

Tipo de motor: ODP

Tipo de cubierta de controlador: NEMA 4

Aprobacin: Underwriters Laboratories

Certificacin: Factory Mutual

La alimentacin elctrica al tablero de control de la bomba jockey ser de 480VAC, 60Hz


trifsica con una lnea de tierra y una proteccin de 15A. El cable a utilizarse ser tipo
THWN 10 AWG.
Lnea de recirculacin


REF: RFE-SPCI-001

RESERVA FRIA ETEN


15/06/2014

Se instalar una vlvula de recirculacin de operacin automtica de , cuya funcin es


prevenir incrementos de temperatura en la bomba cuando entra en operacin a vlvula
cerrada.
Accesorios
Todos los accesorios para la casa de bombas sern instalados conforme a los
requerimientos de la NFPA 20 y cumplirn listamientos UL y aprobaciones FM.
Tubera
La tubera considerada ser de acero negro, cdula 40, A53, en los dimetros
respectivos. La tubera y accesorios se pintarn con una mano de fondo primer y una
mano externa de esmalte color rojo bermelln.
Soportera
La soportera considerada ser fijada hacia las paredes, piso o techo por medio de
elementos de fijacin de acuerdo a lo indicado en planos.
Tableros de Control
Cada bomba dispondr de su propio controlador UL/FM independiente. Los paneles de
control estarn comunicados con la descarga de las bombas a travs de switches de
presin integrados a cada panel de control.
Lneas Piloto
La conexin entre los switches de presin y las lneas de descarga de las bombas
principal y jockey, sern independientes y con tubera de cobre (sensing line) segn se
indica en la NFPA 20. Incluirn manmetros 0 a 300 psi.
3.1.2.

OPERACION DEL SISTEMA

La operacin del sistema ser completamente automtica, existiendo la posibilidad de actuacin


manual en caso de requerirse.
PROCEDIMIENTO DE FUNCIONAMIENTO
1.

Cualquier prdida de presin en el sistema ser sensada por las lneas piloto de las bombas
jockey y principal. Cuando la presin llegue a 115 psi, el tablero de control de la bomba
jockey dar la seal de arranque a sta bomba y el sistema se presurizar nuevamente. Al
alcanzar un valor de 130 psi, la bomba se apagar automticamente. En esta situacin la
bomba elctrica principal no entrar en operacin.

2.

Si se presentan prdidas de presin considerables ante la presencia de un conato de


incendio, la presin bajar notablemente y llegar al nivel de arranque de la bomba jockey y


REF: RFE-SPCI-001

RESERVA FRIA ETEN


15/06/2014

sta arrancar pero no compensar la prdida de presin debido al gasto existente. La


presin llegar a un valor de 105 psi y el tablero de control de la bomba principal elctrica
enviar la seal de arranque y la bomba entrar en operacin suministrando al sistema los
niveles requeridos de caudal-presin para atender la demanda. La bomba diesel de respaldo
entrar en operacin en caso de caer la presin a 95psi. Las bombas elctrica y diesel
permanecern en operacin hasta que se realice un paro manual; la bomba jockey se
apagar automticamente.
3.

En el caso de activacin de la bomba principal elctrica o de la bomba diesel, seales


audibles se activarn en la casa de bombas para notificar que entr en operacin.

4.

La casa de bombas ser completamente supervisada por el sistema de alarma y deteccin


de incendios.

El sistema de rociadores automticos de casa de bombas ha sido diseado de acuerdo a los


siguientes parmetros de clculo:
Tipo de sistema:

Hmedo

Mtodo de diseo:

Hidrulicamente Calculado

Clasificacin del riesgo:

Ordinario Grupo 2

Densidad:

0.2 gpm/ft

Area de cobertura por rociador mxima:

100 ft

Factor K del rociador:

Temperatura de operacin del rociador:

175 F

Nmero de rociadores:

12

Dispositivos en riser:

Vlvula de control y detector de flujo

La operacin del sistema ser automtica, activndose los rociadores que alcancen la
temperatura de ruptura del bulbo. El flujo de agua ser supervisado en el panel de alarma y
deteccin de incendios.
3.2.

SISTEMAS DE ENFRIAMIENTO EN TECHO DE TANQUES DIESEL 48A Y 48B

Los sistemas de diluvio (enfriamiento) se disearon en base a las recomendaciones de la NFPA


15, Water Spray Fixed Systems for Fire Protection, y especificaciones tcnicas de de los
fabricantes de los equipos.
En los sistemas de diluvio, las boquillas de agua estn abiertas y el agua fluye a travs de todas
las boquillas cuando la vlvula de diluvio se abre. El agua se aplicar mediante un patrn
determinado de velocidad, tamao de la gota y densidad, usando boquillas especiales que
proporcionan un cono slido de agua que se proyecta sobre un rea definida.


REF: RFE-SPCI-001

RESERVA FRIA ETEN


15/06/2014

Los sistemas incluirn lneas de deteccin trmica para automatizar la operacin a travs de las
vlvulas de diluvio, segn lo detallado en los planos adjuntos.
3.2.1.

CRITERIOS DE DISEO
Los sistemas fueron diseados de acuerdo a los siguientes parmetros de clculo:
Mtodo de diseo:

Hidrulicamente Calculado

Densidad segn NFPA15 (4-5.2.1):

0.25 gpm/ft

Tipo de boquilla:

D3,

Factor K de la boquilla:

2.3

Presin mnima en la boquilla:

30 psi

3.2.2. OPERACION DEL SISTEMA


La operacin del sistema ser manual, mediante una vlvula de control normalmente cerrada
ubicada luego de la vlvula de diluvio.
En el caso de activacin de cualquiera de los sistemas de diluvio, el flujo de agua ser
supervisado en el panel de alarma y deteccin de incendios para identificar el sistema activado.
3.3.

SISTEMA DE ESPUMA EN TANQUES DE COMBUSTIBLE

El sistema de espuma ha sido diseado en base a las recomendaciones de la NFPA 11,


Standard for Low-Expansion Foam, y especificaciones tcnicas de de los fabricantes de los
equipos.
El sistema de espuma est conformado por un tanque horizontal tipo vejiga el mismo que incluye
un proporcionador para mezcla de concentrado-agua, el tipo de espuma a utilizarse ser
fluropeotenica al 3%. Para control de incendio en los tanques de combustible se instalarn dos
cmaras de espuma por cada tanque, segn lo detallado en los planos.
3.3.1.

CRITERIOS DE DISEO

El sistema de espuma ser diseado de acuerdo a los siguientes parmetros de clculo:


Mtodo de diseo:

Hidrulicamente Calculado

Densidad:

0.1 gpm / ft

Tipo de espuma:

Fluropeotenica al 3%

Tiempo de aplicacin:

30 minutos


REF: RFE-SPCI-001

3.3.2.

RESERVA FRIA ETEN


15/06/2014

Presin mnima en la cmara:

50 psi

Proporcionador:

4" tipo vnturi, tipo II

OPERACION DEL SISTEMA

La operacin del sistema ser automtica, activndose el sistema en el cual se activen al menos
dos de los cuatro detectores de temperatura a instalarse en el techo y que sern supervisados por
el sistema de alarma y deteccin de incendios. Existe la opcin de activacin manual desde la
vlvula de diluvio o desde el panel de control del sistema de alarma y deteccin de incendios.
En el caso de activacin del sistema, el flujo de agua ser supervisado en el panel de alarma y
deteccin de incendios.
3.4.

ALIMENTACION A SISTEMA DE ENFRIAMIENTO DE PARED DE TANQUES DE


COMBUSTIBLE (APORTADO POR OTROS)

Con el fin de garantizar que el equipo de bombeo contra incendios cuente con la capacidad para
abastecer todos los requerimientos para una adecuada proteccin contra incendios de la planta,
F&SS ha corrido un clculo hidrulico conservando las condiciones de diseo del proveedor del
sistema de enfriamiento lateral de los tanques de combustible (48A y 48B).
El sistema de enfriamiento lateral de tanques ha sido diseado por el proveedor de acuerdo a los
siguientes parmetros de clculo:
Mtodo de diseo:

Hidrulicamente Calculado

Densidad:

0.15 gpm / ft

Tipo de boquilla:

VK817,

Factor K de la boquilla (segn clculo hidrulico):

5.6

Presin mnima en la boquilla:

30 psi

Area de clculo:

8,245 ft

Area de clculo:

8,245 ft

Nmero de boquillas:

32

Caudal mnimo requerido:

1,237GPM

De acuerdo al resultado obtenido de los clculos hidrulicos, se comprueba que el equipo de


bombeo contra incendios tiene la capacidad necesaria para operar simultneamente los
siguientes sistemas:


REF: RFE-SPCI-001

RESERVA FRIA ETEN


15/06/2014

Enfriamiento lateral de uno de los tanques diesel (1,324.4GPM) + sistema de espuma de


uno de los tanques diesel (408.9GPM)+ un hidrante (500GPM)

Los clculos se corrieron para una condicin normal de la red contra incendios as como para un
caso crtico con dos tramos en servicio de la red contra incendios.
De acuerdo a los clculos hidrulicos, se recomienda utilizar una boquilla con factor mximo de
K=5.6
3.4.1.

OPERACION DEL SISTEMA

La operacin del sistema ser manual, mediante una vlvula de control normalmente abierta
ubicada luego de la vlvula de diluvio.
En el caso de activacin del sistema, el flujo de agua ser supervisado en el panel de alarma y
deteccin de incendios.
NOTA ACLARATORIA PARA LA OPERACION DE LOS SISTEMAS DE REFRIGERACION EN
TANQUES:
La activacin de los medios de refrigeracin de pared y techo ser manual, pudindose hacer
localmente mediante o remotamente mediante el panel de alarma y deteccin de incendios.
Cada acometida de refrigeracin a un tanque podr dar servicio a la refrigeracin de pared o
techo. Dos vlvulas manuales permitirn seleccionar qu se refrigera.
La posicin por defecto ser refrigeracin de pared.
Las vlvulas dispondrn de interruptores de posicin para supervisar cualquier condicin que no
sea Pared: abierto / Techo: cerrado.


REF: RFE-SPCI-001

3.

RESERVA FRIA ETEN


15/06/2014

CALCULOS HIDRAULICOS

ENFRIAMIENTO EN
TECHO+HIDRANTE
H3+ESPUMA
(TRAYECTORIA
CRITICA)

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 1
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
SOURCE
STATIC
RESID.
FLOW
AVAIL.
TOTAL
REQ'D
NODE
PRESS.
PRESS. @
PRESS. @ DEMAND
PRESS.
TAG
(PSI)
(PSI)
(GPM)
(PSI)
(GPM)
(PSI)
B_ELECTR

140.0

125.0

2000.0

130.4

1570.3

(N/A)

AGGREGATE FLOW ANALYSIS:


TOTAL
TOTAL
OTHER
TOTAL

FLOW AT SOURCE
HOSE STREAM ALLOWANCE AT SOURCE
HOSE STREAM ALLOWANCES
DISCHARGE FROM ACTIVE SPRINKLERS

1570.3
0.0
909.0
661.4

NODE ANALYSIS DATA


NODE TAG
1
2
3
4
8
9
10
11
H6
12
13
H7
14
DIL_T
15
16
H8
17
DIL_TPRI
18
H9
19
20
21
H4
22
GEN_AUX
23
24
H3
25
TAN_DIES
26
TALL_ALM
27
28
H10
29
30
H11
31
OFICINAS
32

ELEVATION
(FT)
2.5
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8

NODE TYPE
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - HOSE STREAM
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

PRESSURE
(PSI)
130.0
132.6
132.5
132.2
132.0
131.8
131.5
131.3
131.3
130.7
130.4
130.4
130.0
130.0
129.7
129.5
129.5
129.1
129.1
128.6
128.6
128.0
127.3
127.3
127.3
127.3
127.3
127.2
126.9
126.7
126.8
126.7
126.8
126.8
126.8
126.8
126.8
126.8
126.8
126.8
126.8
126.8
126.8

DISCHARGE
(GPM)
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 500.0
- - - - - - - - - - - - - - - - - - - - - - - - - - -

GPM
GPM
GPM
GPM

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 2
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
NODE ANALYSIS DATA (cont.)
NODE TAG
H2
33
H1
34
H5
50
51
52
53
RISER_TD
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
B12
B13
B14
B15
B16
B17

ELEVATION
(FT)
-3.8
-3.8
-3.8
-3.8
-3.8
1.0
1.0
1.0
1.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0

NODE TYPE
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30

PRESSURE
(PSI)
126.8
126.8
126.8
126.8
126.8
124.6
122.7
119.8
117.4
72.3
66.2
58.2
47.5
39.9
34.6
32.8
32.1
31.8
31.3
31.1
31.1
31.1
31.1
31.2
31.6
32.8
35.0
38.8
44.4
52.4
63.5
66.5
59.1
49.0
40.8
35.0
33.0
32.3
31.8
31.2
31.1
31.1
31.1
46.6
44.6
39.2
39.2
34.0
34.0
29.2
28.4
28.7
27.9
31.2
31.2
30.8
43.8
30.6
30.6
62.4

DISCHARGE
(GPM)
-

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 15.7
15.4
14.4
14.4
13.4
13.4
12.4
12.3
12.3
12.1
12.9
12.9
12.8
15.2
12.7
12.7
18.2

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 3
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
NODE ANALYSIS DATA (cont.)
NODE TAG
B18
B19
B20
B21
B22
B23
B24
B25
B26
B27
B28
B29
B30
B31
B32
B33
B34
B35
B36
B37
B38
B39
B40
B41
B42
B43
B44
B45
B46
B47
B48
100
101
RISER_ES
102
103
RISER_LD
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126

ELEVATION
(FT)
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
1.0
1.0
70.5
1.0
1.0
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7

NODE TYPE
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
- - - - - - HOSE STREAM
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

PRESSURE
(PSI)
62.4
51.5
51.5
43.6
43.6
38.1
38.1
34.4
34.4
32.2
32.2
31.0
31.0
30.6
30.6
48.1
48.1
40.1
40.1
34.4
34.4
29.4
28.6
29.4
28.6
31.2
31.2
30.6
30.6
30.5
30.5
119.5
117.4
82.9
119.5
119.5
90.2
90.2
90.2
90.2
90.2
90.2
90.2
90.2
90.2
90.2
90.2
90.2
90.2
90.2
90.2
90.2
90.2
90.2
90.2
90.2
90.2
90.2
90.2
90.2

DISCHARGE
(GPM)
18.2
16.5
16.5
15.2
15.2
14.2
14.2
13.5
13.5
13.0
13.0
12.8
12.8
12.7
12.7
16.0
16.0
14.6
14.6
13.5
13.5
12.5
12.3
12.5
12.3
12.9
12.9
12.7
12.7
12.7
12.7
- - - - 409.0
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 4
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
NODE ANALYSIS DATA (cont.)
NODE TAG
127
128
129
130
131
132
133
134
135
VK1
VK2
VK3
VK4
VK5
VK6
VK7
VK8
VK9
VK10
VK11
VK12
VK13
VK14
VK15
VK16
VK17
VK18
VK19
VK20
VK21
VK22
VK23
VK24
VK25
VK26
VK27
VK28
VK29
VK30
VK31
VK32
B_ELECTR

ELEVATION
(FT)
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
2.5

NODE TYPE
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - SOURCE

PRESSURE
(PSI)
90.2
90.2
90.2
90.2
90.2
90.2
90.2
90.2
90.2
91.6
91.6
91.6
91.6
91.6
91.6
91.6
91.6
91.6
91.6
91.6
91.6
91.6
91.6
91.6
91.6
91.6
91.6
91.6
91.6
91.6
91.6
91.6
91.6
91.6
91.6
91.6
91.6
91.6
91.6
91.6
91.6
130.4

DISCHARGE
(GPM)
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1570.3

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 5
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE DATA
PIPE TAG
END
NODES

ELEV.
(FT)

NOZ.
(K)

Q(GPM) DIA(IN)
PT
DISC. VEL(FPS) HW(C)
(PSI) (GPM)
FL/FT

Pipe: 1
B_ELECTR
2.5
1
2.5

SRCE
0.0

130.4
130.0

(N/A)
0.0

2.5
-3.8

0.0
0.0

130.0
132.6

0.0
0.0

2
3

Pipe: 3
-3.8
-3.8

0.0
0.0

132.6
132.5

0.0
0.0

3
4

Pipe: 4
-3.8
-3.8

0.0
0.0

132.5
132.2

0.0
0.0

4
8

Pipe: 5
-3.8
-3.8

0.0
0.0

132.2
132.0

0.0
0.0

8
9

Pipe: 10
-3.8
-3.8

0.0
0.0

132.0
131.8

0.0
0.0

9
10

Pipe: 11
-3.8
-3.8

0.0
0.0

131.8
131.5

0.0
0.0

10
11

Pipe: 12
-3.8
-3.8

0.0
0.0

131.5
131.3

0.0
0.0

11
H6

Pipe: 13
-3.8
-3.8

0.0
0.0

131.3
131.3

0.0
0.0

11
12

Pipe: 14
-3.8
-3.8

0.0
0.0

131.3
130.7

0.0
0.0

12
13

Pipe: 15
-3.8
-3.8

0.0
0.0

130.7
130.4

0.0
0.0

13
H7

Pipe: 16
-3.8
-3.8

0.0
0.0

130.4
130.4

0.0
0.0

13
14

Pipe: 17
-3.8
-3.8

0.0
0.0

130.4
130.0

0.0
0.0

Pipe: 18
-3.8
-3.8

0.0
0.0

130.0
130.0

0.0
0.0

Pipe: 19
-3.8
-3.8

0.0
0.0

130.0
129.7

0.0
0.0

Pipe: 2

1
2

14
DIL_T
14
15

LENGTH
(FT)

PRESS.
SUM.
(PSI)

1570.3
4.7

11.650
150
0.002

PL
6.56
FTG ETCG
TL 206.56

PF
PE
PV

0.5
0.0
0.2

1570.3
4.7

11.650
150
0.002

PL
6.23
FTG E
TL 40.23

PF
PE
PV

0.1
2.7
0.2

1570.3
4.7

11.650
150
0.002

PL
6.56
FTG E
TL 40.56

PF
PE
PV

0.1
0.0
0.2

1570.3
4.7

11.650
150
0.002

PL 32.80
FTG T
TL 108.80

PF
PE
PV

0.2
0.0
0.2

1570.3
4.7

11.650
150
0.002

PL
4.80
FTG T
TL 80.80

PF
PE
PV

0.2
0.0
0.2

1570.3
4.7

11.650
150
0.002

PL
4.80
FTG TG
TL 88.80

PF
PE
PV

0.2
0.0
0.2

1570.3
4.7

11.650
150
0.002

PL 121.36
FTG E
TL 155.36

PF
PE
PV

0.3
0.0
0.2

1570.3
4.7

11.650
150
0.002

PL 18.08
FTG T
TL 94.08

PF
PE
PV

0.2
0.0
0.2

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

1570.3
4.7

11.650
150
0.002

PL 186.96
FTG TG
TL 270.96

PF
PE
PV

0.6
0.0
0.2

1570.3
4.7

11.650
150
0.002

PL 26.24
FTG TG
TL 110.24

PF
PE
PV

0.2
0.0
0.2

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

1570.3
4.7

11.650
150
0.002

PL 109.88
FTG T
TL 185.88

PF
PE
PV

0.4
0.0
0.2

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

1570.3
4.7

11.650
150
0.002

PL 96.76
FTG E
TL 130.76

PF
PE
PV

0.3
0.0
0.2

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 6
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)
15
16

Pipe: 20
-3.8
-3.8

0.0
0.0

129.7
129.5

0.0
0.0

16
H8

Pipe: 21
-3.8
-3.8

0.0
0.0

129.5
129.5

0.0
0.0

16
17

Pipe: 22
-3.8
-3.8

0.0
0.0

129.5
129.1

0.0
0.0

Pipe: 23
17
-3.8
DIL_TPRI
-3.8

0.0
0.0

129.1
129.1

0.0
0.0

17
18

Pipe: 24
-3.8
-3.8

0.0
0.0

129.1
128.6

0.0
0.0

18
H9

Pipe: 25
-3.8
-3.8

0.0
0.0

128.6
128.6

0.0
0.0

18
19

Pipe: 26
-3.8
-3.8

0.0
0.0

128.6
128.0

0.0
0.0

19
20

Pipe: 27
-3.8
-3.8

0.0
0.0

128.0
127.3

0.0
0.0

20
21

Pipe: 28
-3.8
-3.8

0.0
0.0

127.3
127.3

0.0
0.0

21
H4

Pipe: 28A
-3.8
-3.8

0.0
0.0

127.3
127.3

0.0
0.0

21
22

Pipe: 29
-3.8
-3.8

0.0
0.0

127.3
127.3

0.0
0.0

Pipe: 29A
22
-3.8
GEN_AUX
-3.8

0.0
0.0

127.3
127.3

0.0
0.0

20
23

Pipe: 31
-3.8
-3.8

0.0
0.0

127.3
127.2

0.0
0.0

23
24

Pipe: 32
-3.8
-3.8

0.0
0.0

127.2
126.9

0.0
0.0

24
H3

Pipe: 33
-3.8
-3.8

0.0
H.S.

126.9
126.7

0.0
500.0

1570.3
4.7

11.650
150
0.002

PL 18.08
FTG T
TL 94.08

PF
PE
PV

0.2
0.0
0.2

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

1570.3
4.7

11.650
150
0.002

PL 100.04
FTG T
TL 176.04

PF
PE
PV

0.4
0.0
0.2

0.0
0.0

9.790
150
0.000

PL 32.80
FTG G
TL 38.80

PF
PE
PV

0.0
0.0
0.0

1570.3
4.7

11.650
150
0.002

PL 151.54
FTG T
TL 227.54

PF
PE
PV

0.5
0.0
0.2

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

1570.3
4.7

11.650
150
0.002

PL 227.96
FTG E
TL 261.96

PF
PE
PV

0.6
0.0
0.2

1570.3
4.7

11.650
150
0.002

PL 232.88
FTG TG
TL 316.88

PF
PE
PV

0.7
0.0
0.2

0.0
0.0

11.650
150
0.000

PL 70.52
FTG TG
TL 154.52

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

11.650
150
0.000

PL 285.36
FTG T
TL 361.36

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

1570.3
4.7

11.650
150
0.002

PL 20.66
FTG EG
TL 62.66

PF
PE
PV

0.1
0.0
0.2

1570.3
4.7

11.650
150
0.002

PL 40.67
FTG T
TL 116.67

PF
PE
PV

0.3
0.0
0.2

500.0
5.5

6.080
150
0.006

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.2
0.0
0.2

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 7
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)
Pipe: 34
-3.8
-3.8

0.0
0.0

126.9
126.8

0.0
0.0

Pipe: 35
25
-3.8
TAN_DIES
-3.8

0.0
0.0

126.8
126.7

0.0
0.0

Pipe: 36
-3.8
-3.8

0.0
0.0

126.8
126.8

0.0
0.0

Pipe: 37
26
-3.8
TALL_ALM
-3.8

0.0
0.0

126.8
126.8

0.0
0.0

26
27

Pipe: 38
-3.8
-3.8

0.0
0.0

126.8
126.8

0.0
0.0

27
28

Pipe: 39
-3.8
-3.8

0.0
0.0

126.8
126.8

0.0
0.0

28
H10

Pipe: 40
-3.8
-3.8

0.0
0.0

126.8
126.8

0.0
0.0

28
29

Pipe: 41
-3.8
-3.8

0.0
0.0

126.8
126.8

0.0
0.0

29
30

Pipe: 42
-3.8
-3.8

0.0
0.0

126.8
126.8

0.0
0.0

30
H11

Pipe: 43
-3.8
-3.8

0.0
0.0

126.8
126.8

0.0
0.0

30
31

Pipe: 44
-3.8
-3.8

0.0
0.0

126.8
126.8

0.0
0.0

Pipe: 45
31
-3.8
OFICINAS
-3.8

0.0
0.0

126.8
126.8

0.0
0.0

31
32

Pipe: 46
-3.8
-3.8

0.0
0.0

126.8
126.8

0.0
0.0

32
H2

Pipe: 47
-3.8
-3.8

0.0
0.0

126.8
126.8

0.0
0.0

32
33

Pipe: 48
-3.8
-3.8

0.0
0.0

126.8
126.8

0.0
0.0

24
25

25
26

1070.3
3.2

11.650
150
0.001

PL 65.90
FTG T
TL 141.90

PF
PE
PV

0.2
0.0
0.1

1070.3
4.6

9.790
150
0.003

PL 14.20
FTG G
TL 20.20

PF
PE
PV

0.1
0.0
0.1

0.0
0.0

11.650
150
0.000

PL 128.25
FTG T
TL 204.25

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

11.650
150
0.000

PL 60.35
FTG E
TL 94.35

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

11.650
150
0.000

PL 48.22
FTG T
TL 124.22

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

11.650
150
0.000

PL 136.12
FTG E
TL 170.12

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

11.650
150
0.000

PL 48.87
FTG T
TL 124.87

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

11.650
150
0.000

PL 30.18
FTG TG
TL 114.18

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

11.650
150
0.000

PL 157.44
FTG TG
TL 241.44

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

11.650
150
0.000

PL 179.90
FTG T
TL 255.90

PF
PE
PV

0.0
0.0
0.0

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 8
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)
33
H1

Pipe: 49
-3.8
-3.8

0.0
0.0

126.8
126.8

0.0
0.0

33
34

Pipe: 50
-3.8
-3.8

0.0
0.0

126.8
126.8

0.0
0.0

34
H5

Pipe: 51
-3.8
-3.8

0.0
0.0

126.8
126.8

0.0
0.0

Pipe: 60
TAN_DIES
-3.8
50
1.0

0.0
0.0

126.7
124.6

0.0
0.0

50
51

Pipe: 61
1.0
1.0

0.0
0.0

124.6
122.7

0.0
0.0

51
52

Pipe: 62
1.0
1.0

0.0
0.0

122.7
119.8

0.0
0.0

52
53

Pipe: 63
1.0
1.0

0.0
0.0

119.8
117.4

0.0
0.0

Pipe: 64
53
1.0
RISER_TD
82.0

0.0
0.0

117.4
72.3

0.0
0.0

Pipe: 65
RISER_TD
82.0
54
82.0

0.0
0.0

72.3
66.2

0.0
0.0

54
55

Pipe: 66
82.0
82.0

0.0
0.0

66.2
58.2

0.0
0.0

55
56

Pipe: 67
82.0
82.0

0.0
0.0

58.2
47.5

0.0
0.0

56
B1

Pipe: 68
82.0
82.0

0.0
2.3

47.5
46.6

0.0
15.7

56
B2

Pipe: 69
82.0
82.0

0.0
2.3

47.5
44.6

0.0
15.4

56
57

Pipe: 70
82.0
82.0

0.0
0.0

47.5
39.9

0.0
0.0

57
B3

Pipe: 71
82.0
82.0

0.0
2.3

39.9
39.2

0.0
14.4

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

11.650
150
0.000

PL 179.09
FTG T
TL 255.09

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

1070.3
4.6

9.790
150
0.003

PL
4.77
FTG E
TL 32.77

PF
PE
PV

0.1
-2.1
0.1

1070.3
11.8

6.080
120
0.039

PL 32.80
FTG E
TL 46.70

PF
PE
PV

1.8
0.0
0.9

1070.3
11.8

6.080
120
0.039

PL 45.20
FTG T
TL 75.64

PF
PE
PV

3.0
0.0
0.9

661.4
15.0

4.240
120
0.094

PL
9.84
FTG EG
TL 25.06

PF
PE
PV

2.3
0.0
1.5

661.4
15.0

4.240
120
0.094

PL 81.00
FTG T
TL 106.81

PF 10.0
PE -35.1
PV
1.5

213.3
21.8

2.000
120
0.448

PL
9.51
FTG E
TL 13.77

PF
PE
PV

6.2
0.0
3.2

213.3
21.8

2.000
120
0.448

PL 13.45
FTG E
TL 17.71

PF
PE
PV

7.9
0.0
3.2

213.3
21.8

2.000
120
0.448

PL
6.99
FTG 2T
TL 24.02

PF
PE
PV

10.8
0.0
3.2

15.7
6.4

1.000
120
0.105

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.8
0.0
0.3

30.6
12.5

1.000
120
0.360

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

2.9
0.0
1.1

167.0
17.1

2.000
120
0.285

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

7.6
0.0
2.0

14.4
5.9

1.000
120
0.089

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.7
0.0
0.2

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 9
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)
57
B4

Pipe: 72
82.0
82.0

0.0
2.3

39.9
39.2

0.0
14.4

57
58

Pipe: 73
82.0
82.0

0.0
0.0

39.9
34.6

0.0
0.0

58
B5

Pipe: 74
82.0
82.0

0.0
2.3

34.6
34.0

0.0
13.4

58
B6

Pipe: 75
82.0
82.0

0.0
2.3

34.6
34.0

0.0
13.4

58
59

Pipe: 76
82.0
82.0

0.0
0.0

34.6
32.8

0.0
0.0

59
60

Pipe: 77
82.0
82.0

0.0
0.0

32.8
32.1

0.0
0.0

60
B7

Pipe: 78
82.0
82.0

0.0
2.3

32.1
29.2

0.0
12.4

B7
B8

Pipe: 79
82.0
82.0

2.3
2.3

29.2
28.4

12.4
12.3

60
B9

Pipe: 80
82.0
82.0

0.0
2.3

32.1
28.7

0.0
12.3

B9
B10

Pipe: 81
82.0
82.0

2.3
2.3

28.7
27.9

12.3
12.1

59
61

Pipe: 82
82.0
82.0

0.0
0.0

32.8
31.8

0.0
0.0

61
B11

Pipe: 83
82.0
82.0

0.0
2.3

31.8
31.2

0.0
12.9

61
B12

Pipe: 84
82.0
82.0

0.0
2.3

31.8
31.2

0.0
12.9

61
62

Pipe: 85
82.0
82.0

0.0
0.0

31.8
31.3

0.0
0.0

62
B13

Pipe: 86
82.0
82.0

0.0
2.3

31.3
30.8

0.0
12.8

14.4
5.9

1.000
120
0.089

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.7
0.0
0.2

138.2
14.1

2.000
120
0.201

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

5.3
0.0
1.3

13.4
5.5

1.000
120
0.078

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

13.4
5.5

1.000
120
0.078

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

111.4
11.4

2.000
120
0.135

PL
4.76
FTG T
TL 13.28

PF
PE
PV

1.8
0.0
0.9

49.2
5.0

2.000
120
0.030

PL 14.27
FTG T
TL 22.79

PF
PE
PV

0.7
0.0
0.2

24.7
10.1

1.000
120
0.243

PL
4.76
FTG 2ET
TL 11.89

PF
PE
PV

2.9
0.0
0.7

12.3
5.0

1.000
120
0.066

PL
9.51
FTG 2E
TL 12.68

PF
PE
PV

0.8
0.0
0.2

24.5
10.0

1.000
120
0.239

PL
4.76
FTG E2T
TL 14.27

PF
PE
PV

3.4
0.0
0.7

12.1
5.0

1.000
120
0.065

PL
9.51
FTG 2E
TL 12.68

PF
PE
PV

0.8
0.0
0.2

62.2
6.4

2.000
120
0.046

PL
4.76
FTG 2T
TL 21.79

PF
PE
PV

1.0
0.0
0.3

12.9
5.2

1.000
120
0.072

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

12.9
5.2

1.000
120
0.072

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

36.5
3.7

2.000
120
0.017

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.5
0.0
0.1

12.8
5.2

1.000
120
0.071

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 10
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)
B2
B14

Pipe: 87
82.0
82.0

2.3
2.3

44.6
43.8

15.4
15.2

62
63

Pipe: 88
82.0
82.0

0.0
0.0

31.3
31.1

0.0
0.0

63
B15

Pipe: 89
82.0
82.0

0.0
2.3

31.1
30.6

0.0
12.7

63
B16

Pipe: 90
82.0
82.0

0.0
2.3

31.1
30.6

0.0
12.7

63
64

Pipe: 91
82.0
82.0

0.0
0.0

31.1
31.1

0.0
0.0

64
65

Pipe: 92
82.0
82.0

0.0
0.0

31.1
31.1

0.0
0.0

65
66

Pipe: 93
82.0
82.0

0.0
0.0

31.1
31.1

0.0
0.0

66
67

Pipe: 94
82.0
82.0

0.0
0.0

31.1
31.2

0.0
0.0

67
B31

Pipe: 95
82.0
82.0

0.0
2.3

31.2
30.6

0.0
12.7

67
B32

Pipe: 96
82.0
82.0

0.0
2.3

31.2
30.6

0.0
12.7

67
68

Pipe: 97
82.0
82.0

0.0
0.0

31.2
31.6

0.0
0.0

68
B29

Pipe: 98
82.0
82.0

0.0
2.3

31.6
31.0

0.0
12.8

68
B30

Pipe: 99
82.0
82.0

0.0
2.3

31.6
31.0

0.0
12.8

68
69

Pipe: 100
82.0
82.0

0.0
0.0

31.6
32.8

0.0
0.0

69
B27

Pipe: 101
82.0
82.0

0.0
2.3

32.8
32.2

0.0
13.0

15.2
6.2

1.000
120
0.099

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.8
0.0
0.3

23.7
2.4

2.000
120
0.008

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.2
0.0
0.0

12.7
5.2

1.000
120
0.071

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

12.7
5.2

1.000
120
0.071

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

-1.7
0.2

2.000
120
0.000

PL
6.99
FTG E
TL 11.25

PF
PE
PV

0.0
0.0
0.0

-1.7
0.2

2.000
120
0.000

PL 13.45
FTG E
TL 17.71

PF
PE
PV

0.0
0.0
0.0

-1.7
0.2

2.000
120
0.000

PL
9.51
FTG T
TL 18.03

PF
PE
PV

0.0
0.0
0.0

-9.8
1.0

2.000
120
0.001

PL
6.99
FTG 2T
TL 24.02

PF
PE
PV

0.0
0.0
0.0

12.7
5.2

1.000
120
0.071

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

12.7
5.2

1.000
120
0.071

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

-35.2
3.6

2.000
120
0.016

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.4
0.0
0.1

12.8
5.2

1.000
120
0.072

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

12.8
5.2

1.000
120
0.072

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

-60.9
6.2

2.000
120
0.044

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

1.2
0.0
0.3

13.0
5.3

1.000
120
0.075

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 11
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)
69
B28

Pipe: 102
82.0
82.0

0.0
2.3

32.8
32.2

0.0
13.0

69
70

Pipe: 103
82.0
82.0

0.0
0.0

32.8
35.0

0.0
0.0

70
B25

Pipe: 104
82.0
82.0

0.0
2.3

35.0
34.4

0.0
13.5

70
B26

Pipe: 105
82.0
82.0

0.0
2.3

35.0
34.4

0.0
13.5

70
71

Pipe: 106
82.0
82.0

0.0
0.0

35.0
38.8

0.0
0.0

71
B23

Pipe: 107
82.0
82.0

0.0
2.3

38.8
38.1

0.0
14.2

71
B24

Pipe: 108
82.0
82.0

0.0
2.3

38.8
38.1

0.0
14.2

71
72

Pipe: 109
82.0
82.0

0.0
0.0

38.8
44.4

0.0
0.0

72
B21

Pipe: 110
82.0
82.0

0.0
2.3

44.4
43.6

0.0
15.2

72
B22

Pipe: 111
82.0
82.0

0.0
2.3

44.4
43.6

0.0
15.2

72
73

Pipe: 112
82.0
82.0

0.0
0.0

44.4
52.4

0.0
0.0

73
B19

Pipe: 113
82.0
82.0

0.0
2.3

52.4
51.5

0.0
16.5

73
B20

Pipe: 114
82.0
82.0

0.0
2.3

52.4
51.5

0.0
16.5

73
74

Pipe: 115
82.0
82.0

0.0
0.0

52.4
63.5

0.0
0.0

74
B17

Pipe: 116
82.0
82.0

0.0
2.3

63.5
62.4

0.0
18.2

13.0
5.3

1.000
120
0.075

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

-86.9
8.9

2.000
120
0.085

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

2.3
0.0
0.5

13.5
5.5

1.000
120
0.079

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

13.5
5.5

1.000
120
0.079

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

-113.9
11.6

2.000
120
0.140

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

3.7
0.0
0.9

14.2
5.8

1.000
120
0.087

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.7
0.0
0.2

14.2
5.8

1.000
120
0.087

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.7
0.0
0.2

-142.3
14.5

2.000
120
0.212

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

5.6
0.0
1.4

15.2
6.2

1.000
120
0.099

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.8
0.0
0.3

15.2
6.2

1.000
120
0.099

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.8
0.0
0.3

-172.7
17.6

2.000
120
0.303

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

8.0
0.0
2.1

16.5
6.7

1.000
120
0.115

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.9
0.0
0.3

16.5
6.7

1.000
120
0.115

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.9
0.0
0.3

-205.7
21.0

2.000
120
0.419

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

11.1
0.0
3.0

18.2
7.4

1.000
120
0.138

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

1.1
0.0
0.4

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 12
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)
Pipe: 117
82.0
82.0

0.0
2.3

63.5
62.4

0.0
18.2

Pipe: 118
74
82.0
RISER_TD
82.0

0.0
0.0

63.5
72.3

0.0
0.0

Pipe: 119
RISER_TD
82.0
75
82.0

0.0
0.0

72.3
66.5

0.0
0.0

75
76

Pipe: 120
82.0
82.0

0.0
0.0

66.5
59.1

0.0
0.0

76
77

Pipe: 121
82.0
82.0

0.0
0.0

59.1
49.0

0.0
0.0

77
B33

Pipe: 122
82.0
82.0

0.0
2.3

49.0
48.1

0.0
16.0

77
B34

Pipe: 123
82.0
82.0

0.0
2.3

49.0
48.1

0.0
16.0

77
78

Pipe: 124
82.0
82.0

0.0
0.0

49.0
40.8

0.0
0.0

78
B35

Pipe: 125
82.0
82.0

0.0
2.3

40.8
40.1

0.0
14.6

78
B36

Pipe: 126
82.0
82.0

0.0
2.3

40.8
40.1

0.0
14.6

78
79

Pipe: 127
82.0
82.0

0.0
0.0

40.8
35.0

0.0
0.0

79
B37

Pipe: 128
82.0
82.0

0.0
2.3

35.0
34.4

0.0
13.5

79
B38

Pipe: 129
82.0
82.0

0.0
2.3

35.0
34.4

0.0
13.5

79
80

Pipe: 130
82.0
82.0

0.0
0.0

35.0
33.0

0.0
0.0

80
81

Pipe: 131
82.0
82.0

0.0
0.0

33.0
32.3

0.0
0.0

74
B18

18.2
7.4

1.000
120
0.138

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

1.1
0.0
0.4

-242.0
24.7

2.000
120
0.566

PL
6.99
FTG T
TL 15.51

PF
PE
PV

8.8
0.0
4.1

206.1
21.0

2.000
120
0.420

PL
9.51
FTG E
TL 13.77

PF
PE
PV

5.8
0.0
3.0

206.1
21.0

2.000
120
0.420

PL 13.45
FTG E
TL 17.71

PF
PE
PV

7.4
0.0
3.0

206.1
21.0

2.000
120
0.420

PL
6.99
FTG 2T
TL 24.02

PF
PE
PV

10.1
0.0
3.0

16.0
6.5

1.000
120
0.108

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.9
0.0
0.3

16.0
6.5

1.000
120
0.108

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.9
0.0
0.3

174.1
17.8

2.000
120
0.308

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

8.2
0.0
2.1

14.6
5.9

1.000
120
0.091

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.7
0.0
0.2

14.6
5.9

1.000
120
0.091

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.7
0.0
0.2

145.0
14.8

2.000
120
0.219

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

5.8
0.0
1.5

13.5
5.5

1.000
120
0.079

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

13.5
5.5

1.000
120
0.079

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

118.1
12.1

2.000
120
0.150

PL
4.76
FTG T
TL 13.28

PF
PE
PV

2.0
0.0
1.0

49.5
5.1

2.000
120
0.030

PL 14.27
FTG T
TL 22.79

PF
PE
PV

0.7
0.0
0.2

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 13
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)
81
B39

Pipe: 132
82.0
82.0

0.0
2.3

32.3
29.4

0.0
12.5

B39
B40

Pipe: 133
82.0
82.0

2.3
2.3

29.4
28.6

12.5
12.3

81
B41

Pipe: 134
82.0
82.0

0.0
2.3

32.3
29.4

0.0
12.5

B41
B42

Pipe: 135
82.0
82.0

2.3
2.3

29.4
28.6

12.5
12.3

80
82

Pipe: 136
82.0
82.0

0.0
0.0

33.0
31.8

0.0
0.0

82
B43

Pipe: 137
82.0
82.0

0.0
2.3

31.8
31.2

0.0
12.9

82
B44

Pipe: 138
82.0
82.0

0.0
2.3

31.8
31.2

0.0
12.9

82
83

Pipe: 139
82.0
82.0

0.0
0.0

31.8
31.2

0.0
0.0

83
B45

Pipe: 140
82.0
82.0

0.0
2.3

31.2
30.6

0.0
12.7

83
B46

Pipe: 141
82.0
82.0

0.0
2.3

31.2
30.6

0.0
12.7

83
84

Pipe: 142
82.0
82.0

0.0
0.0

31.2
31.1

0.0
0.0

84
B47

Pipe: 143
82.0
82.0

0.0
2.3

31.1
30.5

0.0
12.7

84
B48

Pipe: 144
82.0
82.0

0.0
2.3

31.1
30.5

0.0
12.7

84
85

Pipe: 145
82.0
82.0

0.0
0.0

31.1
31.1

0.0
0.0

85
86

Pipe: 146
82.0
82.0

0.0
0.0

31.1
31.1

0.0
0.0

24.8
10.1

1.000
120
0.244

PL
4.76
FTG 2ET
TL 11.89

PF
PE
PV

2.9
0.0
0.7

12.3
5.0

1.000
120
0.067

PL
9.51
FTG 2E
TL 12.68

PF
PE
PV

0.8
0.0
0.2

24.8
10.1

1.000
120
0.244

PL
4.76
FTG 2ET
TL 11.89

PF
PE
PV

2.9
0.0
0.7

12.3
5.0

1.000
120
0.067

PL
9.51
FTG 2E
TL 12.68

PF
PE
PV

0.8
0.0
0.2

68.5
7.0

2.000
120
0.055

PL
4.76
FTG 2T
TL 21.79

PF
PE
PV

1.2
0.0
0.3

12.9
5.3

1.000
120
0.072

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

12.9
5.3

1.000
120
0.072

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

42.8
4.4

2.000
120
0.023

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.6
0.0
0.1

12.7
5.2

1.000
120
0.071

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

12.7
5.2

1.000
120
0.071

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

17.3
1.8

2.000
120
0.004

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.1
0.0
0.0

12.7
5.2

1.000
120
0.071

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

12.7
5.2

1.000
120
0.071

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

-8.1
0.8

2.000
120
0.001

PL
6.99
FTG E
TL 11.25

PF
PE
PV

0.0
0.0
0.0

-8.1
0.8

2.000
120
0.001

PL 13.45
FTG E
TL 17.71

PF
PE
PV

0.0
0.0
0.0

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 14
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)
86
66

Pipe: 147
82.0
82.0

0.0
0.0

31.1
31.1

0.0
0.0

52
100

Pipe: 150
1.0
1.0

0.0
0.0

119.8
119.5

0.0
0.0

100
101

Pipe: 151
1.0
1.0

0.0
0.0

119.5
117.4

0.0
0.0

Pipe: 152
101
1.0
RISER_ES
70.5

0.0
H.S.

117.4
82.9

0.0
409.0

100
102

Pipe: 153
1.0
1.0

0.0
0.0

119.5
119.5

0.0
0.0

102
103

Pipe: 154
1.0
1.0

0.0
0.0

119.5
119.5

0.0
0.0

Pipe: 155
103
1.0
RISER_LD
68.7

0.0
0.0

119.5
90.2

0.0
0.0

Pipe: 156
RISER_LD
68.7
104
68.7

0.0
0.0

90.2
90.2

0.0
0.0

104
VK16

Pipe: 157
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

104
105

Pipe: 158
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

105
VK15

Pipe: 159
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

105
106

Pipe: 160
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

106
VK14

Pipe: 161
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

106
107

Pipe: 162
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

107
VK13

Pipe: 163
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

-8.1
0.8

2.000
120
0.001

PL
9.51
FTG T
TL 18.03

PF
PE
PV

0.0
0.0
0.0

409.0
4.5

6.080
120
0.007

PL 10.17
FTG T
TL 40.61

PF
PE
PV

0.3
0.0
0.1

409.0
9.3

4.240
120
0.038

PL 11.41
FTG ET2G
TL 55.09

PF
PE
PV

2.1
0.0
0.6

409.0
9.3

4.240
120
0.038

PL 69.52
FTG ET2G
TL 113.20

PF
4.4
PE -30.1
PV
0.6

0.0
0.0

6.080
120
0.000

PL 16.01
FTG E
TL 29.91

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

6.080
120
0.000

PL 20.04
FTG ET2G
TL 71.00

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

7.980
120
0.000

PL 67.65
FTG T
TL 100.74

PF
0.0
PE -29.3
PV
0.0

0.0
0.0

6.080
120
0.000

PL
1.93
FTG T
TL 32.37

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 15
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)
107
108

Pipe: 164
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

108
VK12

Pipe: 165
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

108
109

Pipe: 166
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

109
VK11

Pipe: 167
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

109
110

Pipe: 168
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

110
VK10

Pipe: 169
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

110
111

Pipe: 170
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

111
VK9

Pipe: 171
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

111
112

Pipe: 172
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

112
VK8

Pipe: 173
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

112
113

Pipe: 174
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

113
VK7

Pipe: 175
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

113
114

Pipe: 176
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

114
VK6

Pipe: 177
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

114
115

Pipe: 178
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 16
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)
115
VK5

Pipe: 179
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

115
116

Pipe: 180
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

116
VK4

Pipe: 181
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

116
117

Pipe: 182
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

117
VK3

Pipe: 183
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

117
118

Pipe: 184
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

118
VK2

Pipe: 185
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

118
119

Pipe: 186
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

119
VK1

Pipe: 187
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

Pipe: 188
RISER_LD
68.7
120
68.7

0.0
0.0

90.2
90.2

0.0
0.0

120
VK17

Pipe: 189
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

120
121

Pipe: 190
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

121
VK18

Pipe: 191
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

121
122

Pipe: 192
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

122
VK19

Pipe: 193
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
1.93
FTG T
TL 32.37

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 17
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)
122
123

Pipe: 194
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

123
VK20

Pipe: 195
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

123
124

Pipe: 196
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

124
VK21

Pipe: 197
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

124
125

Pipe: 198
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

125
VK22

Pipe: 199
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

125
126

Pipe: 200
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

126
VK23

Pipe: 201
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

126
127

Pipe: 202
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

127
VK24

Pipe: 203
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

127
128

Pipe: 204
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

128
VK25

Pipe: 205
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

128
129

Pipe: 206
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

129
VK26

Pipe: 207
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

129
130

Pipe: 208
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 18
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)
130
VK27

Pipe: 209
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

130
131

Pipe: 210
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

131
VK28

Pipe: 211
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

131
132

Pipe: 212
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

132
VK29

Pipe: 213
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

132
133

Pipe: 214
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

133
VK30

Pipe: 215
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

133
134

Pipe: 216
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

134
VK31

Pipe: 217
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

134
135

Pipe: 218
68.7
68.7

0.0
0.0

90.2
90.2

0.0
0.0

135
VK32

Pipe: 219
68.7
65.4

0.0
0.0

90.2
91.6

0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

NOTES:
(1) Calculations were performed by the HASS computer program

(2) The system has been calculated to provide an average


imbalance at each node of 0.001 gpm and a maximum
imbalance at any node of 0.003 gpm.
(3) Velocity pressures are printed for information only, and are
not used in balancing the system. Maximum water velocity
is 24.7 ft/sec at pipe 118.

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 19
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
(4) PIPE FITTINGS TABLE
Pipe Table Name: CUSTOM.PIP
PAGE: *
Diameter
(in)
1.049
1.500
2.067
PAGE: E
Diameter
(in)
4.240
6.080
7.980
9.790
11.650

MATERIAL: S40
HWC: 120
Equivalent Fitting Lengths in Feet
E
T
L
C
B
G
A
Ell
Tee LngEll ChkVlv BfyVlv GatVlv AlmChk
2.00
5.00
2.00
5.00
6.00
1.00 10.00
4.50
9.01
3.00 10.51
9.01
1.50 15.01
5.00 10.00
3.00 11.00
6.00
1.00 10.00
MATERIAL: PVC150
HWC: 150
Equivalent Fitting Lengths in Feet
E
T
L
C
B
G
N
Ell
Tee LngEl ChkVl BfyVl GatVl NPTee
19.00 39.00 12.00 43.00 23.00
4.00 39.00
21.00 46.00 14.00 49.00 15.00
5.00 46.00
26.00 50.00 19.00 64.00 17.00
6.00 50.00
28.00 64.00 20.00 70.00 24.00
6.00 64.00
34.00 76.00 23.00 82.00 27.00
8.00 76.00

D
DPVlv
10.00
15.01
10.00

N
NPTee
5.00
9.01
10.00

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 20
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
WATER SUPPLY ANALYSIS

Static: 140.00 psi Resid: 125.00 psi Flow: 2000.0 gpm

180.0

LEGEND
150.0
G
A
G
E
P
R
E
S
S
U
R
E
(
p
s
i
)

2
1

Available pressure
130.41 psi @ 1570.3 gpm

Required pressure
130.41 psi @ 1570.3 gpm

120.0

90.0

60.0

30.0

0.0
-14.7
400600 800 1000

1200
1400
1600
FLOW (GPM)

1800

2000

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 21
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
SPRINKLER SYSTEM DIAGRAM WITH FLOWPLOT
1516
<24>
<20> <22> 17
1570.3
1570.31570.3
<23>
<21>
0.0
0.0
H8 DIL_TPRI

18

H9

<25>
0.0

<26>
1570.3

19

<19>
1570.3

14<18>
DIL_T
0.0
<27>
1570.3
<17>
1570.3

13<16>
H7
0.0
<15>
12 1570.3

GEN_AUX

22

H4
<29A>
0.0

<28A>
0.0
21 <28>20
0.0 <31>

<29>
0.0

23<32>
1570.3
24 <34>25
27
<36> 26 <38>
1570.3
1070.3 <35> 0.0
0.0
TAN_DIES 1070.3
<33>
<37>
50
500.0 <61>
0.0
<39>
H3
TALL_ALM
0.0
1070.3
102
100
52 <62>
51
<153>
<150>
<63>
<151>
VK9
112
VK8
VK10
VK7
VK11
75
53
54
0.0
409.0
1070.3
VK6
<172>
28
VK12
<170>
<173>
<174>
101
VK5
<168>
<119>
<65>
<176>
<154>
VK13
<166>
<178>
VK4
<164>
VK14
<180>
661.4
VK3
<162>
<118>
409.0
<182>
VK15
111
<120>
<66>
110
B17
B18
74
113
VK2
<160>
109
RISER_TD
114
<184>
108
VK16
0.0
<116>
<117>
0.0
0.0
RISER_ES
0.0
115
76
0.0
550.0
<158>
206.1
213.3
0.0
VK1
107
103
<186>
0.0
116
VK17
0.0
<156>
106
0.0
117
<188>
0.0
242.0
<115>
105
0.0
VK18
206.1
118
<121>
<67>
<190>
0.0
0.0
B33
B34
77
B19
B20
73
104
B1
56
B2213.3
18.2
18.2
0.0
119
VK19
RISER_LD
<192>
<122>
<123>
<113>
<114>
<68>
<69>
0.0
120
0.0
<40>
VK20 <194>
205.7
121
206.1
213.3
0.0
<124>
<70>
<112>
VK21
<196>
122
B40
B35
B36
78
B21
B22
72
B3
57
B
B8
4
0.0
16.0
16.0
16.5
16.5
15.7
30.6
0.0
<125>
<126>
<110>
<111>
<71>
<72>
VK22
<198>
123
0.0
174.1
167.0
172.7
VK23
124
<200>
0.0
<127>
<73>
<133>
<109>
<79>
H10
B39
B37
B38
79
B23
B24
71
B5
58
B
B
6
7
14.6
14.6
15.2
15.2
14.4
14.4
VK24
125
<202>
0.0
<128>
<129>
<107>
<108>
<74>
<75>
<87>
126
VK25
<132>
<130>
<76>
<78>
<204>
0.0
81
80
59
60
145.0
138.2
12.3
142.3
12.3
<131>
<77>
<106>
127
VK26
<206>
0.0
<134>
<136>
<82>
<80>
B41
B43
B44
82
B25
B26
70
B11
B12
61
B9
15.2
13.5
13.5
14.2
14.2
13.4
13.4
<137>
<138>
<104>
<105>
<83>
<84>
VK27
128
24.8
118.1
111.4
24.7
<208>
0.0
113.9
49.5
49.2
VK28
129
<210>
0.0
<135>
<139>
<85>
<81>
<103>
24.8
68.5
62.2
B42
B45
B46
83
B27
B28
69
B13
B14
62
B10 24.5
VK29
12.9
12.9
13.5
13.5
12.9
12.9
<212>
130
0.0
<140>
<141>
<101>
<102>
<86>
VK30
<214>
131
0.0
12.3
42.8
36.5
12.1
86.9
VK31
<142>
<88>
<100>
<216>
132
0.0
VK32
B47
B48
84
B29
B30
68
B15
B16
63
12.7
12.7
13.0
13.0
12.8
<218>
133
<143>
<144>
<98>
<99>
<89>
<90>
0.0
134
17.3
23.7
60.9
0.0
<145>
<91>
<97>
85
64
<41>
135
0.0
B31
B32
67
12.7
12.7
12.8
12.8
12.7
12.7
<95>
<96>
8.1
1.7
<146>
<92>
35.2
0.0
<94>
86
66
65
<147>
<93>
12.7
12.7
8.1
1.7
9.8
8.1
1.7

<14>
1570.3

B_ELECTR<1>
23
H5
<3>
1
1570.3
1570.3
11<13>
H6
<4>
<51>
0.0
<12>
1570.3 0.0
10 1570.3
9<5>
84
34
<11> <10>
1570.3 1570.3
1570.3

H1

<50>
0.0

33

H2
<49>
0.0

<48>
0.0

32

OFICINAS H11
<47>
0.0

<46>
0.0

<45>
<43>
0.00.0
31<44>
30 <42>
29
0.0 0.0


REF: RFE-SPCI-001

RESERVA FRIA ETEN


15/06/2014

ENFRIAMIENTO EN
TECHO+HIDRANTE
H3+ESPUMA
(TRAYECTORIA
NORMAL)

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 1
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
SOURCE
STATIC
RESID.
FLOW
AVAIL.
TOTAL
REQ'D
NODE
PRESS.
PRESS. @
PRESS. @ DEMAND
PRESS.
TAG
(PSI)
(PSI)
(GPM)
(PSI)
(GPM)
(PSI)
B_ELECTR

140.0

125.0

2000.0

130.2

1587.2

(N/A)

AGGREGATE FLOW ANALYSIS:

TOTAL
TOTAL
OTHER
TOTAL

FLOW AT SOURCE
HOSE STREAM ALLOWANCE AT SOURCE
HOSE STREAM ALLOWANCES
DISCHARGE FROM ACTIVE SPRINKLERS

1587.2
0.0
909.0
678.3

NODE ANALYSIS DATA


NODE TAG

1
2
3
4
8
9
10
11
H6
12
13
H7
14
DIL_T
15
16
H8
17
DIL_TPRI
18
H9
19
20
21
H4
22
GEN_AUX
23
24
H3
25
TAN_DIES
26
TALL_ALM
27
28
H10
29
30
H11
31
OFICINAS
32

ELEVATION
(FT)
2.5
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8

NODE TYPE

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - HOSE STREAM
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

PRESSURE
(PSI)
129.7
132.4
132.3
132.0
132.0
131.9
131.8
131.7
131.7
131.5
131.5
131.5
131.4
131.4
131.4
131.4
131.4
131.4
131.4
131.4
131.4
131.3
131.3
131.3
131.3
131.4
131.4
131.2
131.1
130.9
131.1
131.1
131.2
131.2
131.3
131.3
131.3
131.4
131.5
131.5
131.5
131.5
131.6

DISCHARGE
(GPM)
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 500.0
- - - - - - - - - - - - - - - - - - - - - - - - - - -

GPM
GPM
GPM
GPM

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 2
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (NORMAL
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
NODE ANALYSIS DATA (cont.)
NODE TAG

H2
33
H1
34
H5
35
50
51
52
53
RISER_TD
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
B12
B13
B14
B15
B16

ELEVATION
(FT)
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
1.0
1.0
1.0
1.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0

NODE TYPE

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30

PRESSURE
(PSI)
131.6
131.8
131.8
131.9
131.9
132.0
128.9
127.0
123.9
121.5
75.9
69.5
61.1
49.9
42.0
36.4
34.5
33.8
33.5
33.0
32.8
32.8
32.8
32.8
32.8
33.2
34.5
36.8
40.8
46.6
55.1
66.7
69.9
62.1
51.5
42.9
36.8
34.7
34.0
33.5
32.8
32.7
32.7
32.7
49.0
46.9
41.2
41.2
35.7
35.7
30.8
29.9
30.2
29.4
32.9
32.9
32.4
46.1
32.2
32.2

DISCHARGE
(GPM)
-

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 16.1
15.7
14.8
14.8
13.7
13.7
12.8
12.6
12.6
12.5
13.2
13.2
13.1
15.6
13.0
13.0

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 3
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
NODE ANALYSIS DATA (cont.)
NODE TAG

B17
B18
B19
B20
B21
B22
B23
B24
B25
B26
B27
B28
B29
B30
B31
B32
B33
B34
B35
B36
B37
B38
B39
B40
B41
B42
B43
B44
B45
B46
B47
B48
100
101
RISER_ES
102
103
RISER_LD
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125

ELEVATION
(FT)
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
1.0
1.0
70.5
1.0
1.0
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7

NODE TYPE

K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
K= 2.30
- - - - - - HOSE STREAM
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

PRESSURE
(PSI)
65.6
65.6
54.1
54.1
45.8
45.8
40.0
40.0
36.2
36.2
33.9
33.9
32.7
32.7
32.2
32.2
50.6
50.6
42.2
42.2
36.2
36.2
31.0
30.1
31.0
30.1
32.9
32.9
32.2
32.2
32.1
32.1
123.7
121.6
87.1
123.7
123.7
94.4
94.4
94.4
94.4
94.4
94.4
94.4
94.4
94.4
94.4
94.4
94.4
94.4
94.4
94.4
94.4
94.4
94.4
94.4
94.4
94.4
94.4
94.4

DISCHARGE
(GPM)
18.6
18.6
16.9
16.9
15.6
15.6
14.6
14.6
13.8
13.8
13.4
13.4
13.1
13.1
13.1
13.1
16.4
16.4
14.9
14.9
13.8
13.8
12.8
12.6
12.8
12.6
13.2
13.2
13.1
13.1
13.0
13.0
- - - - 409.0
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 4
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
NODE ANALYSIS DATA (cont.)
NODE TAG

126
127
128
129
130
131
132
133
134
135
VK1
VK2
VK3
VK4
VK5
VK6
VK7
VK8
VK9
VK10
VK11
VK12
VK13
VK14
VK15
VK16
VK17
VK18
VK19
VK20
VK21
VK22
VK23
VK24
VK25
VK26
VK27
VK28
VK29
VK30
VK31
VK32
B_ELECTR

ELEVATION
(FT)
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
2.5

NODE TYPE

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - SOURCE

PRESSURE
(PSI)
94.4
94.4
94.4
94.4
94.4
94.4
94.4
94.4
94.4
94.4
95.8
95.8
95.8
95.8
95.8
95.8
95.8
95.8
95.8
95.8
95.8
95.8
95.8
95.8
95.8
95.8
95.8
95.8
95.8
95.8
95.8
95.8
95.8
95.8
95.8
95.8
95.8
95.8
95.8
95.8
95.8
95.8
130.2

DISCHARGE
(GPM)
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1587.2

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 5
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE DATA
PIPE TAG
END
NODES

ELEV.
(FT)

NOZ.
(K)

Q(GPM) DIA(IN)
PT
DISC. VEL(FPS) HW(C)
(PSI) (GPM)
FL/FT

Pipe: 1
B_ELECTR
2.5
1
2.5

SRCE
0.0

130.2
129.7

(N/A)
0.0

11.650
150
0.002

PL
6.56
FTG ETCG
TL 206.56

PF
PE
PV

0.5
0.0
0.2

1587.2
4.8

11.650
150
0.002

PL
6.23
FTG E
TL 40.23

PF
PE
PV

0.1
2.7
0.2

1587.2
4.8

11.650
150
0.002

PL
6.56
FTG E
TL 40.56

PF
PE
PV

0.1
0.0
0.2

1587.2
4.8

11.650
150
0.002

PL 32.80
FTG T
TL 108.80

PF
PE
PV

0.2
0.0
0.2

887.7
2.7

11.650
150
0.001

PL
4.80
FTG T
TL 80.80

PF
PE
PV

0.1
0.0
0.0

887.7
2.7

11.650
150
0.001

PL
4.80
FTG TG
TL 88.80

PF
PE
PV

0.1
0.0
0.0

887.7
2.7

11.650
150
0.001

PL 121.36
FTG E
TL 155.36

PF
PE
PV

0.1
0.0
0.0

887.7
2.7

11.650
150
0.001

PL 18.08
FTG T
TL 94.08

PF
PE
PV

0.1
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

887.7
2.7

11.650
150
0.001

PL 186.96
FTG TG
TL 270.96

PF
PE
PV

0.2
0.0
0.0

347.7
1.0

11.650
150
0.000

PL 26.24
FTG TG
TL 110.24

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

347.7
1.0

11.650
150
0.000

PL 109.88
FTG T
TL 185.88

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

347.7
1.0

11.650
150
0.000

PL 96.76
FTG E
TL 130.76

PF
PE
PV

0.0
0.0
0.0

Pipe: 2
2.5
-3.8

0.0
0.0

129.7
132.4

0.0
0.0

2
3

Pipe: 3
-3.8
-3.8

0.0
0.0

132.4
132.3

0.0
0.0

3
4

Pipe: 4
-3.8
-3.8

0.0
0.0

132.3
132.0

0.0
0.0

4
8

Pipe: 5
-3.8
-3.8

0.0
0.0

132.0
132.0

0.0
0.0

8
9

Pipe: 10
-3.8
-3.8

0.0
0.0

132.0
131.9

0.0
0.0

9
10

Pipe: 11
-3.8
-3.8

0.0
0.0

131.9
131.8

0.0
0.0

10
11

Pipe: 12
-3.8
-3.8

0.0
0.0

131.8
131.7

0.0
0.0

11
H6

Pipe: 13
-3.8
-3.8

0.0
0.0

131.7
131.7

0.0
0.0

11
12

Pipe: 14
-3.8
-3.8

0.0
0.0

131.7
131.5

0.0
0.0

12
13

Pipe: 15
-3.8
-3.8

0.0
0.0

131.5
131.5

0.0
0.0

13
H7

Pipe: 16
-3.8
-3.8

0.0
0.0

131.5
131.5

0.0
0.0

13
14

Pipe: 17
-3.8
-3.8

0.0
0.0

131.5
131.4

0.0
0.0

Pipe: 18
-3.8
-3.8

0.0
0.0

131.4
131.4

0.0
0.0

Pipe: 19
-3.8
-3.8

0.0
0.0

131.4
131.4

0.0
0.0

14
15

PRESS.
SUM.
(PSI)

1587.2
4.8

1
2

14
DIL_T

LENGTH
(FT)

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 6
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)

15
16

Pipe: 20
-3.8
-3.8

0.0
0.0

131.4
131.4

0.0
0.0

16
H8

Pipe: 21
-3.8
-3.8

0.0
0.0

131.4
131.4

0.0
0.0

16
17

Pipe: 22
-3.8
-3.8

0.0
0.0

131.4
131.4

0.0
0.0

Pipe: 23
17
-3.8
DIL_TPRI
-3.8

0.0
0.0

131.4
131.4

0.0
0.0

17
18

Pipe: 24
-3.8
-3.8

0.0
0.0

131.4
131.4

0.0
0.0

18
H9

Pipe: 25
-3.8
-3.8

0.0
0.0

131.4
131.4

0.0
0.0

18
19

Pipe: 26
-3.8
-3.8

0.0
0.0

131.4
131.3

0.0
0.0

19
20

Pipe: 27
-3.8
-3.8

0.0
0.0

131.3
131.3

0.0
0.0

20
21

Pipe: 28
-3.8
-3.8

0.0
0.0

131.3
131.3

0.0
0.0

21
H4

Pipe: 28A
-3.8
-3.8

0.0
0.0

131.3
131.3

0.0
0.0

21
22

Pipe: 29
-3.8
-3.8

0.0
0.0

131.3
131.4

0.0
0.0

Pipe: 29A
22
-3.8
GEN_AUX
-3.8

0.0
0.0

131.4
131.4

0.0
0.0

22
12

Pipe: 30
-3.8
-3.8

0.0
0.0

131.4
131.5

0.0
0.0

20
23

Pipe: 31
-3.8
-3.8

0.0
0.0

131.3
131.2

0.0
0.0

23
24

Pipe: 32
-3.8
-3.8

0.0
0.0

131.2
131.1

0.0
0.0

347.7
1.0

11.650
150
0.000

PL 18.08
FTG T
TL 94.08

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

347.7
1.0

11.650
150
0.000

PL 100.04
FTG T
TL 176.04

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

9.790
150
0.000

PL 32.80
FTG G
TL 38.80

PF
PE
PV

0.0
0.0
0.0

347.7
1.0

11.650
150
0.000

PL 151.54
FTG T
TL 227.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

347.7
1.0

11.650
150
0.000

PL 227.96
FTG E
TL 261.96

PF
PE
PV

0.0
0.0
0.0

347.7
1.0

11.650
150
0.000

PL 232.88
FTG TG
TL 316.88

PF
PE
PV

0.0
0.0
0.0

-540.0
1.6

11.650
150
0.000

PL 70.52
FTG TG
TL 154.52

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

-540.0
1.6

11.650
150
0.000

PL 285.36
FTG T
TL 361.36

PF
PE
PV

0.1
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

-540.0
1.6

11.650
150
0.000

PL 141.70
FTG G
TL 149.70

PF
PE
PV

0.0
0.0
0.0

887.7
2.7

11.650
150
0.001

PL 20.66
FTG EG
TL 62.66

PF
PE
PV

0.0
0.0
0.0

887.7
2.7

11.650
150
0.001

PL 40.67
FTG T
TL 116.67

PF
PE
PV

0.1
0.0
0.0

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 7
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)

24
H3

Pipe: 33
-3.8
-3.8

0.0
H.S.

131.1
130.9

0.0
500.0

24
25

Pipe: 34
-3.8
-3.8

0.0
0.0

131.1
131.1

0.0
0.0

Pipe: 35
25
-3.8
TAN_DIES
-3.8

0.0
0.0

131.1
131.1

0.0
0.0

Pipe: 36
-3.8
-3.8

0.0
0.0

131.1
131.2

0.0
0.0

Pipe: 37
26
-3.8
TALL_ALM
-3.8

0.0
0.0

131.2
131.2

0.0
0.0

26
27

Pipe: 38
-3.8
-3.8

0.0
0.0

131.2
131.3

0.0
0.0

27
28

Pipe: 39
-3.8
-3.8

0.0
0.0

131.3
131.3

0.0
0.0

28
H10

Pipe: 40
-3.8
-3.8

0.0
0.0

131.3
131.3

0.0
0.0

28
29

Pipe: 41
-3.8
-3.8

0.0
0.0

131.3
131.4

0.0
0.0

29
30

Pipe: 42
-3.8
-3.8

0.0
0.0

131.4
131.5

0.0
0.0

30
H11

Pipe: 43
-3.8
-3.8

0.0
0.0

131.5
131.5

0.0
0.0

30
31

Pipe: 44
-3.8
-3.8

0.0
0.0

131.5
131.5

0.0
0.0

Pipe: 45
31
-3.8
OFICINAS
-3.8

0.0
0.0

131.5
131.5

0.0
0.0

31
32

Pipe: 46
-3.8
-3.8

0.0
0.0

131.5
131.6

0.0
0.0

32
H2

Pipe: 47
-3.8
-3.8

0.0
0.0

131.6
131.6

0.0
0.0

25
26

500.0
5.5

6.080
150
0.006

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.2
0.0
0.2

387.7
1.2

11.650
150
0.000

PL 65.90
FTG T
TL 141.90

PF
PE
PV

0.0
0.0
0.0

1087.2
4.6

9.790
150
0.003

PL 14.20
FTG G
TL 20.20

PF
PE
PV

0.1
0.0
0.1

-699.5
2.1

11.650
150
0.001

PL 128.25
FTG T
TL 204.25

PF
PE
PV

0.1
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

-699.5
2.1

11.650
150
0.001

PL 60.35
FTG E
TL 94.35

PF
PE
PV

0.0
0.0
0.0

-699.5
2.1

11.650
150
0.001

PL 48.22
FTG T
TL 124.22

PF
PE
PV

0.1
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

-699.5
2.1

11.650
150
0.001

PL 136.12
FTG E
TL 170.12

PF
PE
PV

0.1
0.0
0.0

-699.5
2.1

11.650
150
0.001

PL 48.87
FTG T
TL 124.87

PF
PE
PV

0.1
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

-699.5
2.1

11.650
150
0.001

PL 30.18
FTG TG
TL 114.18

PF
PE
PV

0.1
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

-699.5
2.1

11.650
150
0.001

PL 157.44
FTG TG
TL 241.44

PF
PE
PV

0.1
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 8
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)

32
33

Pipe: 48
-3.8
-3.8

0.0
0.0

131.6
131.8

0.0
0.0

33
H1

Pipe: 49
-3.8
-3.8

0.0
0.0

131.8
131.8

0.0
0.0

33
34

Pipe: 50
-3.8
-3.8

0.0
0.0

131.8
131.9

0.0
0.0

34
H5

Pipe: 51
-3.8
-3.8

0.0
0.0

131.9
131.9

0.0
0.0

34
35

Pipe: 52
-3.8
-3.8

0.0
0.0

131.9
132.0

0.0
0.0

4
35

Pipe: 53
-3.8
-3.8

0.0
0.0

132.0
132.0

0.0
0.0

Pipe: 60
TAN_DIES
-3.8
50
1.0

0.0
0.0

131.1
128.9

0.0
0.0

50
51

Pipe: 61
1.0
1.0

0.0
0.0

128.9
127.0

0.0
0.0

51
52

Pipe: 62
1.0
1.0

0.0
0.0

127.0
123.9

0.0
0.0

52
53

Pipe: 63
1.0
1.0

0.0
0.0

123.9
121.5

0.0
0.0

Pipe: 64
53
1.0
RISER_TD
82.0

0.0
0.0

121.5
75.9

0.0
0.0

Pipe: 65
RISER_TD
82.0
54
82.0

0.0
0.0

75.9
69.5

0.0
0.0

54
55

Pipe: 66
82.0
82.0

0.0
0.0

69.5
61.1

0.0
0.0

55
56

Pipe: 67
82.0
82.0

0.0
0.0

61.1
49.9

0.0
0.0

56
B1

Pipe: 68
82.0
82.0

0.0
2.3

49.9
49.0

0.0
16.1

-699.5
2.1

11.650
150
0.001

PL 179.90
FTG T
TL 255.90

PF
PE
PV

0.1
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

-699.5
2.1

11.650
150
0.001

PL 179.09
FTG T
TL 255.09

PF
PE
PV

0.1
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

-699.5
2.1

11.650
150
0.001

PL 61.66
FTG T
TL 137.66

PF
PE
PV

0.1
0.0
0.0

699.5
2.1

11.650
150
0.001

PL
4.80
FTG TG
TL 88.80

PF
PE
PV

0.0
0.0
0.0

1087.2
4.6

9.790
150
0.003

PL
4.77
FTG E
TL 32.77

PF
PE
PV

0.1
-2.1
0.1

1087.2
12.0

6.080
120
0.041

PL 32.80
FTG E
TL 46.70

PF
PE
PV

1.9
0.0
1.0

1087.2
12.0

6.080
120
0.041

PL 45.20
FTG T
TL 75.64

PF
PE
PV

3.1
0.0
1.0

678.3
15.4

4.240
120
0.098

PL
9.84
FTG EG
TL 25.06

PF
PE
PV

2.5
0.0
1.6

678.3
15.4

4.240
120
0.098

PL 81.00
FTG T
TL 106.81

PF 10.5
PE -35.1
PV
1.6

218.7
22.3

2.000
120
0.469

PL
9.51
FTG E
TL 13.77

PF
PE
PV

6.5
0.0
3.4

218.7
22.3

2.000
120
0.469

PL 13.45
FTG E
TL 17.71

PF
PE
PV

8.3
0.0
3.4

218.7
22.3

2.000
120
0.469

PL
6.99
FTG 2T
TL 24.02

PF
PE
PV

11.3
0.0
3.4

16.1
6.6

1.000
120
0.110

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.9
0.0
0.3

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 9
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (NORMAL
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)

56
B2

Pipe: 69
82.0
82.0

0.0
2.3

49.9
46.9

0.0
15.7

56
57

Pipe: 70
82.0
82.0

0.0
0.0

49.9
42.0

0.0
0.0

57
B3

Pipe: 71
82.0
82.0

0.0
2.3

42.0
41.2

0.0
14.8

57
B4

Pipe: 72
82.0
82.0

0.0
2.3

42.0
41.2

0.0
14.8

57
58

Pipe: 73
82.0
82.0

0.0
0.0

42.0
36.4

0.0
0.0

58
B5

Pipe: 74
82.0
82.0

0.0
2.3

36.4
35.7

0.0
13.7

58
B6

Pipe: 75
82.0
82.0

0.0
2.3

36.4
35.7

0.0
13.7

58
59

Pipe: 76
82.0
82.0

0.0
0.0

36.4
34.5

0.0
0.0

59
60

Pipe: 77
82.0
82.0

0.0
0.0

34.5
33.8

0.0
0.0

60
B7

Pipe: 78
82.0
82.0

0.0
2.3

33.8
30.8

0.0
12.8

B7
B8

Pipe: 79
82.0
82.0

2.3
2.3

30.8
29.9

12.8
12.6

60
B9

Pipe: 80
82.0
82.0

0.0
2.3

33.8
30.2

0.0
12.6

B9
B10

Pipe: 81
82.0
82.0

2.3
2.3

30.2
29.4

12.6
12.5

59
61

Pipe: 82
82.0
82.0

0.0
0.0

34.5
33.5

0.0
0.0

61
B11

Pipe: 83
82.0
82.0

0.0
2.3

33.5
32.9

0.0
13.2

31.4
12.8

1.000
120
0.377

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

3.0
0.0
1.1

171.3
17.5

2.000
120
0.298

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

7.9
0.0
2.1

14.8
6.0

1.000
120
0.094

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.7
0.0
0.2

14.8
6.0

1.000
120
0.094

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.7
0.0
0.2

141.7
14.5

2.000
120
0.210

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

5.6
0.0
1.4

13.7
5.6

1.000
120
0.082

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.7
0.0
0.2

13.7
5.6

1.000
120
0.082

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.7
0.0
0.2

114.2
11.7

2.000
120
0.141

PL
4.76
FTG T
TL 13.28

PF
PE
PV

1.9
0.0
0.9

50.4
5.2

2.000
120
0.031

PL 14.27
FTG T
TL 22.79

PF
PE
PV

0.7
0.0
0.2

25.3
10.3

1.000
120
0.254

PL
4.76
FTG 2ET
TL 11.89

PF
PE
PV

3.0
0.0
0.7

12.6
5.1

1.000
120
0.070

PL
9.51
FTG 2E
TL 12.68

PF
PE
PV

0.9
0.0
0.2

25.1
10.3

1.000
120
0.250

PL
4.76
FTG E2T
TL 14.27

PF
PE
PV

3.6
0.0
0.7

12.5
5.1

1.000
120
0.068

PL
9.51
FTG 2E
TL 12.68

PF
PE
PV

0.9
0.0
0.2

63.8
6.5

2.000
120
0.048

PL
4.76
FTG 2T
TL 21.79

PF
PE
PV

1.0
0.0
0.3

13.2
5.4

1.000
120
0.076

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 10
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)

61
B12

Pipe: 84
82.0
82.0

0.0
2.3

33.5
32.9

0.0
13.2

61
62

Pipe: 85
82.0
82.0

0.0
0.0

33.5
33.0

0.0
0.0

62
B13

Pipe: 86
82.0
82.0

0.0
2.3

33.0
32.4

0.0
13.1

B2
B14

Pipe: 87
82.0
82.0

2.3
2.3

46.9
46.1

15.7
15.6

62
63

Pipe: 88
82.0
82.0

0.0
0.0

33.0
32.8

0.0
0.0

63
B15

Pipe: 89
82.0
82.0

0.0
2.3

32.8
32.2

0.0
13.0

63
B16

Pipe: 90
82.0
82.0

0.0
2.3

32.8
32.2

0.0
13.0

63
64

Pipe: 91
82.0
82.0

0.0
0.0

32.8
32.8

0.0
0.0

64
65

Pipe: 92
82.0
82.0

0.0
0.0

32.8
32.8

0.0
0.0

65
66

Pipe: 93
82.0
82.0

0.0
0.0

32.8
32.8

0.0
0.0

66
67

Pipe: 94
82.0
82.0

0.0
0.0

32.8
32.8

0.0
0.0

67
B31

Pipe: 95
82.0
82.0

0.0
2.3

32.8
32.2

0.0
13.1

67
B32

Pipe: 96
82.0
82.0

0.0
2.3

32.8
32.2

0.0
13.1

67
68

Pipe: 97
82.0
82.0

0.0
0.0

32.8
33.2

0.0
0.0

68
B29

Pipe: 98
82.0
82.0

0.0
2.3

33.2
32.7

0.0
13.1

13.2
5.4

1.000
120
0.076

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

37.4
3.8

2.000
120
0.018

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.5
0.0
0.1

13.1
5.3

1.000
120
0.075

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

15.6
6.4

1.000
120
0.104

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.8
0.0
0.3

24.3
2.5

2.000
120
0.008

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.2
0.0
0.0

13.0
5.3

1.000
120
0.074

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

13.0
5.3

1.000
120
0.074

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

-1.7
0.2

2.000
120
0.000

PL
6.99
FTG E
TL 11.25

PF
PE
PV

0.0
0.0
0.0

-1.7
0.2

2.000
120
0.000

PL 13.45
FTG E
TL 17.71

PF
PE
PV

0.0
0.0
0.0

-1.7
0.2

2.000
120
0.000

PL
9.51
FTG T
TL 18.03

PF
PE
PV

0.0
0.0
0.0

-10.0
1.0

2.000
120
0.002

PL
6.99
FTG 2T
TL 24.02

PF
PE
PV

0.0
0.0
0.0

13.1
5.3

1.000
120
0.075

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

13.1
5.3

1.000
120
0.075

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

-36.1
3.7

2.000
120
0.017

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.4
0.0
0.1

13.1
5.4

1.000
120
0.076

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 11
DATE: 6/12/2014C:\HAS6\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)

68
B30

Pipe: 99
82.0
82.0

0.0
2.3

33.2
32.7

0.0
13.1

68
69

Pipe: 100
82.0
82.0

0.0
0.0

33.2
34.5

0.0
0.0

69
B27

Pipe: 101
82.0
82.0

0.0
2.3

34.5
33.9

0.0
13.4

69
B28

Pipe: 102
82.0
82.0

0.0
2.3

34.5
33.9

0.0
13.4

69
70

Pipe: 103
82.0
82.0

0.0
0.0

34.5
36.8

0.0
0.0

70
B25

Pipe: 104
82.0
82.0

0.0
2.3

36.8
36.2

0.0
13.8

70
B26

Pipe: 105
82.0
82.0

0.0
2.3

36.8
36.2

0.0
13.8

70
71

Pipe: 106
82.0
82.0

0.0
0.0

36.8
40.8

0.0
0.0

71
B23

Pipe: 107
82.0
82.0

0.0
2.3

40.8
40.0

0.0
14.6

71
B24

Pipe: 108
82.0
82.0

0.0
2.3

40.8
40.0

0.0
14.6

71
72

Pipe: 109
82.0
82.0

0.0
0.0

40.8
46.6

0.0
0.0

72
B21

Pipe: 110
82.0
82.0

0.0
2.3

46.6
45.8

0.0
15.6

72
B22

Pipe: 111
82.0
82.0

0.0
2.3

46.6
45.8

0.0
15.6

72
73

Pipe: 112
82.0
82.0

0.0
0.0

46.6
55.1

0.0
0.0

73
B19

Pipe: 113
82.0
82.0

0.0
2.3

55.1
54.1

0.0
16.9

13.1
5.4

1.000
120
0.076

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

-62.4
6.4

2.000
120
0.046

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

1.2
0.0
0.3

13.4
5.5

1.000
120
0.078

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

13.4
5.5

1.000
120
0.078

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

-89.2
9.1

2.000
120
0.089

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

2.4
0.0
0.6

13.8
5.7

1.000
120
0.083

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.7
0.0
0.2

13.8
5.7

1.000
120
0.083

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.7
0.0
0.2

-116.9
11.9

2.000
120
0.147

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

3.9
0.0
1.0

14.6
5.9

1.000
120
0.091

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.7
0.0
0.2

14.6
5.9

1.000
120
0.091

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.7
0.0
0.2

-146.0
14.9

2.000
120
0.222

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

5.9
0.0
1.5

15.6
6.4

1.000
120
0.103

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.8
0.0
0.3

15.6
6.4

1.000
120
0.103

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.8
0.0
0.3

-177.1
18.1

2.000
120
0.318

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

8.4
0.0
2.2

16.9
6.9

1.000
120
0.121

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

1.0
0.0
0.3

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 12
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)

73
B20

Pipe: 114
82.0
82.0

0.0
2.3

55.1
54.1

0.0
16.9

73
74

Pipe: 115
82.0
82.0

0.0
0.0

55.1
66.7

0.0
0.0

74
B17

Pipe: 116
82.0
82.0

0.0
2.3

66.7
65.6

0.0
18.6

74
B18

Pipe: 117
82.0
82.0

0.0
2.3

66.7
65.6

0.0
18.6

Pipe: 118
74
82.0
RISER_TD
82.0

0.0
0.0

66.7
75.9

0.0
0.0

Pipe: 119
RISER_TD
82.0
75
82.0

0.0
0.0

75.9
69.9

0.0
0.0

75
76

Pipe: 120
82.0
82.0

0.0
0.0

69.9
62.1

0.0
0.0

76
77

Pipe: 121
82.0
82.0

0.0
0.0

62.1
51.5

0.0
0.0

77
B33

Pipe: 122
82.0
82.0

0.0
2.3

51.5
50.6

0.0
16.4

77
B34

Pipe: 123
82.0
82.0

0.0
2.3

51.5
50.6

0.0
16.4

77
78

Pipe: 124
82.0
82.0

0.0
0.0

51.5
42.9

0.0
0.0

78
B35

Pipe: 125
82.0
82.0

0.0
2.3

42.9
42.2

0.0
14.9

78
B36

Pipe: 126
82.0
82.0

0.0
2.3

42.9
42.2

0.0
14.9

78
79

Pipe: 127
82.0
82.0

0.0
0.0

42.9
36.8

0.0
0.0

79
B37

Pipe: 128
82.0
82.0

0.0
2.3

36.8
36.2

0.0
13.8

16.9
6.9

1.000
120
0.121

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

1.0
0.0
0.3

-211.0
21.5

2.000
120
0.439

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

11.6
0.0
3.1

18.6
7.6

1.000
120
0.144

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

1.1
0.0
0.4

18.6
7.6

1.000
120
0.144

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

1.1
0.0
0.4

-248.2
25.3

2.000
120
0.593

PL
6.99
FTG T
TL 15.51

PF
PE
PV

9.2
0.0
4.3

211.3
21.6

2.000
120
0.440

PL
9.51
FTG E
TL 13.77

PF
PE
PV

6.1
0.0
3.1

211.3
21.6

2.000
120
0.440

PL 13.45
FTG E
TL 17.71

PF
PE
PV

7.8
0.0
3.1

211.3
21.6

2.000
120
0.440

PL
6.99
FTG 2T
TL 24.02

PF
PE
PV

10.6
0.0
3.1

16.4
6.7

1.000
120
0.113

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.9
0.0
0.3

16.4
6.7

1.000
120
0.113

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.9
0.0
0.3

178.6
18.2

2.000
120
0.323

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

8.6
0.0
2.2

14.9
6.1

1.000
120
0.096

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.8
0.0
0.3

14.9
6.1

1.000
120
0.096

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.8
0.0
0.3

148.8
15.2

2.000
120
0.230

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

6.1
0.0
1.6

13.8
5.6

1.000
120
0.083

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.7
0.0
0.2

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 13
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)

79
B38

Pipe: 129
82.0
82.0

0.0
2.3

36.8
36.2

0.0
13.8

79
80

Pipe: 130
82.0
82.0

0.0
0.0

36.8
34.7

0.0
0.0

80
81

Pipe: 131
82.0
82.0

0.0
0.0

34.7
34.0

0.0
0.0

81
B39

Pipe: 132
82.0
82.0

0.0
2.3

34.0
31.0

0.0
12.8

B39
B40

Pipe: 133
82.0
82.0

2.3
2.3

31.0
30.1

12.8
12.6

81
B41

Pipe: 134
82.0
82.0

0.0
2.3

34.0
31.0

0.0
12.8

B41
B42

Pipe: 135
82.0
82.0

2.3
2.3

31.0
30.1

12.8
12.6

80
82

Pipe: 136
82.0
82.0

0.0
0.0

34.7
33.5

0.0
0.0

82
B43

Pipe: 137
82.0
82.0

0.0
2.3

33.5
32.9

0.0
13.2

82
B44

Pipe: 138
82.0
82.0

0.0
2.3

33.5
32.9

0.0
13.2

82
83

Pipe: 139
82.0
82.0

0.0
0.0

33.5
32.8

0.0
0.0

83
B45

Pipe: 140
82.0
82.0

0.0
2.3

32.8
32.2

0.0
13.1

83
B46

Pipe: 141
82.0
82.0

0.0
2.3

32.8
32.2

0.0
13.1

83
84

Pipe: 142
82.0
82.0

0.0
0.0

32.8
32.7

0.0
0.0

84
B47

Pipe: 143
82.0
82.0

0.0
2.3

32.7
32.1

0.0
13.0

13.8
5.6

1.000
120
0.083

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.7
0.0
0.2

121.1
12.4

2.000
120
0.157

PL
4.76
FTG T
TL 13.28

PF
PE
PV

2.1
0.0
1.0

50.8
5.2

2.000
120
0.032

PL 14.27
FTG T
TL 22.79

PF
PE
PV

0.7
0.0
0.2

25.4
10.4

1.000
120
0.256

PL
4.76
FTG 2ET
TL 11.89

PF
PE
PV

3.0
0.0
0.7

12.6
5.2

1.000
120
0.070

PL
9.51
FTG 2E
TL 12.68

PF
PE
PV

0.9
0.0
0.2

25.4
10.4

1.000
120
0.256

PL
4.76
FTG 2ET
TL 11.89

PF
PE
PV

3.0
0.0
0.7

12.6
5.2

1.000
120
0.070

PL
9.51
FTG 2E
TL 12.68

PF
PE
PV

0.9
0.0
0.2

70.3
7.2

2.000
120
0.057

PL
4.76
FTG 2T
TL 21.79

PF
PE
PV

1.3
0.0
0.3

13.2
5.4

1.000
120
0.076

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

13.2
5.4

1.000
120
0.076

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

43.9
4.5

2.000
120
0.024

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.6
0.0
0.1

13.1
5.3

1.000
120
0.075

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

13.1
5.3

1.000
120
0.075

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

17.8
1.8

2.000
120
0.005

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.1
0.0
0.0

13.0
5.3

1.000
120
0.074

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 14
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)

84
B48

Pipe: 144
82.0
82.0

0.0
2.3

32.7
32.1

0.0
13.0

84
85

Pipe: 145
82.0
82.0

0.0
0.0

32.7
32.7

0.0
0.0

85
86

Pipe: 146
82.0
82.0

0.0
0.0

32.7
32.7

0.0
0.0

86
66

Pipe: 147
82.0
82.0

0.0
0.0

32.7
32.8

0.0
0.0

52
100

Pipe: 150
1.0
1.0

0.0
0.0

123.9
123.7

0.0
0.0

100
101

Pipe: 151
1.0
1.0

0.0
0.0

123.7
121.6

0.0
0.0

Pipe: 152
101
1.0
RISER_ES
70.5

0.0
H.S.

121.6
87.1

0.0
409.0

100
102

Pipe: 153
1.0
1.0

0.0
0.0

123.7
123.7

0.0
0.0

102
103

Pipe: 154
1.0
1.0

0.0
0.0

123.7
123.7

0.0
0.0

Pipe: 155
103
1.0
RISER_LD
68.7

0.0
0.0

123.7
94.4

0.0
0.0

Pipe: 156
RISER_LD
68.7
104
68.7

0.0
0.0

94.4
94.4

0.0
0.0

104
VK16

Pipe: 157
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

104
105

Pipe: 158
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

105
VK15

Pipe: 159
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

105
106

Pipe: 160
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

13.0
5.3

1.000
120
0.074

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.6
0.0
0.2

-8.3
0.8

2.000
120
0.001

PL
6.99
FTG E
TL 11.25

PF
PE
PV

0.0
0.0
0.0

-8.3
0.8

2.000
120
0.001

PL 13.45
FTG E
TL 17.71

PF
PE
PV

0.0
0.0
0.0

-8.3
0.8

2.000
120
0.001

PL
9.51
FTG T
TL 18.03

PF
PE
PV

0.0
0.0
0.0

409.0
4.5

6.080
120
0.007

PL 10.17
FTG T
TL 40.61

PF
PE
PV

0.3
0.0
0.1

409.0
9.3

4.240
120
0.038

PL 11.41
FTG ET2G
TL 55.09

PF
PE
PV

2.1
0.0
0.6

409.0
9.3

4.240
120
0.038

PL 69.52
FTG ET2G
TL 113.20

PF
4.4
PE -30.1
PV
0.6

0.0
0.0

6.080
120
0.000

PL 16.01
FTG E
TL 29.91

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

6.080
120
0.000

PL 20.04
FTG ET2G
TL 71.00

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

7.980
120
0.000

PL 67.65
FTG T
TL 100.74

PF
0.0
PE -29.3
PV
0.0

0.0
0.0

6.080
120
0.000

PL
1.93
FTG T
TL 32.37

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 15
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)

106
VK14

Pipe: 161
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

106
107

Pipe: 162
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

107
VK13

Pipe: 163
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

107
108

Pipe: 164
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

108
VK12

Pipe: 165
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

108
109

Pipe: 166
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

109
VK11

Pipe: 167
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

109
110

Pipe: 168
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

110
VK10

Pipe: 169
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

110
111

Pipe: 170
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

111
VK9

Pipe: 171
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

111
112

Pipe: 172
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

112
VK8

Pipe: 173
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

112
113

Pipe: 174
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

113
VK7

Pipe: 175
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 16
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)

113
114

Pipe: 176
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

114
VK6

Pipe: 177
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

114
115

Pipe: 178
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

115
VK5

Pipe: 179
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

115
116

Pipe: 180
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

116
VK4

Pipe: 181
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

116
117

Pipe: 182
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

117
VK3

Pipe: 183
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

117
118

Pipe: 184
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

118
VK2

Pipe: 185
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

118
119

Pipe: 186
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

119
VK1

Pipe: 187
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

Pipe: 188
RISER_LD
68.7
120
68.7

0.0
0.0

94.4
94.4

0.0
0.0

120
VK17

Pipe: 189
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

120
121

Pipe: 190
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
1.93
FTG T
TL 32.37

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 17
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)

121
VK18

Pipe: 191
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

121
122

Pipe: 192
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

122
VK19

Pipe: 193
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

122
123

Pipe: 194
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

123
VK20

Pipe: 195
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

123
124

Pipe: 196
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

124
VK21

Pipe: 197
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

124
125

Pipe: 198
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

125
VK22

Pipe: 199
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

125
126

Pipe: 200
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

126
VK23

Pipe: 201
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

126
127

Pipe: 202
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

127
VK24

Pipe: 203
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

127
128

Pipe: 204
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

128
VK25

Pipe: 205
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 18
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)

128
129

Pipe: 206
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

129
VK26

Pipe: 207
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

129
130

Pipe: 208
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

130
VK27

Pipe: 209
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

130
131

Pipe: 210
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

131
VK28

Pipe: 211
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

131
132

Pipe: 212
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

132
VK29

Pipe: 213
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

132
133

Pipe: 214
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

133
VK30

Pipe: 215
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

133
134

Pipe: 216
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

134
VK31

Pipe: 217
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

134
135

Pipe: 218
68.7
68.7

0.0
0.0

94.4
94.4

0.0
0.0

135
VK32

Pipe: 219
68.7
65.4

0.0
0.0

94.4
95.8

0.0
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

0.0
0.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.500
120
0.000

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

0.0
1.4
0.0

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 19
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
NOTES:
(1) Calculations were performed by the HASS computer program

(2) The system has been calculated to provide an average


imbalance at each node of 0.001 gpm and a maximum
imbalance at any node of 0.003 gpm.
(3) Velocity pressures are printed for information only, and are
not used in balancing the system. Maximum water velocity
is 25.3 ft/sec at pipe 118.

(4) PIPE FITTINGS TABLE


Pipe Table Name: CUSTOM.PIP
PAGE: *
Diameter
(in)
1.049
1.500
2.067
PAGE: E
Diameter
(in)
4.240
6.080
7.980
9.790
11.650

MATERIAL: S40
HWC: 120
Equivalent Fitting Lengths in Feet
E
T
L
C
B
G
A
Ell
Tee LngEll ChkVlv BfyVlv GatVlv AlmChk
2.00
5.00
2.00
5.00
6.00
1.00 10.00
4.50
9.01
3.00 10.51
9.01
1.50 15.01
5.00 10.00
3.00 11.00
6.00
1.00 10.00
MATERIAL: PVC150
HWC: 150
Equivalent Fitting Lengths in Feet
E
T
L
C
B
G
N
Ell
Tee LngEl ChkVl BfyVl GatVl NPTee
19.00 39.00 12.00 43.00 23.00
4.00 39.00
21.00 46.00 14.00 49.00 15.00
5.00 46.00
26.00 50.00 19.00 64.00 17.00
6.00 50.00
28.00 64.00 20.00 70.00 24.00
6.00 64.00
34.00 76.00 23.00 82.00 27.00
8.00 76.00

D
DPVlv
10.00
15.01
10.00

N
NPTee
5.00
9.01
10.00

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 20
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA

WATER SUPPLY ANALYSIS

Static: 140.00 psi Resid: 125.00 psi Flow: 2000.0 gpm

180.0

LEGEND
150.0

G
A
G
E
P
R
E
S
S
U
R
E
(
p
s
i
)

2
1

Available pressure
130.22 psi @ 1587.2 gpm

Required pressure
130.22 psi @ 1587.2 gpm

120.0

90.0

60.0

30.0

0.0

-14.7
400600 800 1000

1200
1400
1600
FLOW (GPM)

1800

2000

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 21
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO EN TECHO+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
SPRINKLER SYSTEM DIAGRAM WITH FLOWPLOT
1516
<24>
<20> <22> 17
347.7
347.7 347.7
<23>
<21>
0.0
0.0
H8 DIL_TPRI

18

<26>
347.7

19

<25>
0.0
H9

<19>
347.7

14<18>
DIL_T
0.0
<27>
347.7

<17>
347.7

GEN_AUX
13<16>
H7
0.0
<29A>
<15>
0.0
12 347.7<30>
22
540.0

H4
<28A>
0.0
21 <28>20
540.0 <31>

<29>
540.0

23<32>
887.7
24 <34>25
27
<36> 26 <38>
887.7 387.7 <35>699.5
699.5
TAN_DIES 1087.2
<33>
<37>
50
500.0 <61>
0.0
<39>
H3
TALL_ALM
699.5
1087.2
102
100
52 <62>
51
<153>
<150>
<63>
<151>
VK9
112
VK8
VK10
VK7
VK11
75
53
54
0.0
409.0
1087.2
VK6
<172>
28
VK12
<170>
<173>
<174>
101
VK5
<168>
<119>
<65>
<176>
<154>
VK13
<166>
<178>
VK4
<164>
VK14
<180>
678.3
VK3
<162>
<118>
409.0
<182>
VK15
111
<120>
<66>
110
B17
B18
74
113
VK2
<160>
109
RISER_TD
114
<184>
108
VK16
0.0
<116>
<117>
0.0
0.0
RISER_ES
0.0
115
76
0.0
550.0
<158>
211.3
218.7
0.0
VK1
107
103
<186>
0.0
116
VK17
0.0
<156>
106
0.0
117
<188>
0.0
248.2
<115>
105
0.0
VK18
211.3
118
<121>
<67>
<190>
0.0
0.0
B33
B34
77
B19
B20
73
104
B1
56
B2218.7
18.6
18.6
0.0
119
VK19
RISER_LD
<192>
<122>
<123>
<113>
<114>
<68>
<69>
0.0
120
0.0
<40>
VK20 <194>
211.0
121
211.3
218.7
0.0
<124>
<70>
<112>
VK21
<196>
122
B40
B35
B36
78
B21
B22
72
B3
57
B
B8
4
0.0
16.4
16.4
16.9
16.9
16.1
31.4
0.0
<125>
<126>
<110>
<111>
<71>
<72>
VK22
<198>
123
0.0
178.6
171.3
177.1
VK23
124
<200>
0.0
<127>
<73>
<133>
<109>
<79>
H10
B39
B37
B38
79
B23
B24
71
B5
58
B
B
6
7
14.9
14.9
15.6
15.6
14.8
14.8
VK24
125
<202>
0.0
<128>
<129>
<107>
<108>
<74>
<75>
<87>
126
VK25
<132>
<130>
<76>
<78>
<204>
0.0
81
80
59
60
148.8
141.7
12.6
146.0
12.6
<131>
<77>
<106>
127
VK26
<206>
0.0
<134>
<136>
<82>
<80>
B41
B43
B44
82
B25
B26
70
B11
B12
61
B9
15.6
13.8
13.8
14.6
14.6
13.7
13.7
<137>
<138>
<104>
<105>
<83>
<84>
VK27
128
25.4
121.1
114.2
25.3
<208>
0.0
116.9
50.8
50.4
VK28
129
<210>
0.0
<135>
<139>
<85>
<81>
<103>
25.4
70.3
63.8
B42
B45
B46
83
B27
B28
69
B13
B14
62
B10 25.1
VK29
13.2
13.2
13.8
13.8
13.2
13.2
<212>
130
0.0
<140>
<141>
<101>
<102>
<86>
VK30
<214>
131
0.0
12.6
43.9
37.4
12.5
89.2
VK31
<142>
<88>
<100>
<216>
132
0.0
VK32
B47
B48
84
B29
B30
68
B15
B16
63
13.1
13.1
13.4
13.4
13.1
<218>
133
<143>
<144>
<98>
<99>
<89>
<90>
0.0
134
17.8
24.3
62.4
0.0
<145>
<91>
<97>
85
64
<41>
135
0.0
B31
B32
67
13.0
13.0
13.1
13.1
13.0
13.0
<95>
<96>
8.3
1.7
<146>
<92>
36.1
699.5
<94>
86
66
65
<147>
<93>
13.1
13.1
8.3
1.7
10.0
8.3
1.7

<14>
887.7

B_ELECTR<1>
23
H5
<3>
1
1587.2
1587.2
11<13>
H6
<4>
<51>
0.0
<12>
1587.2 0.0
10 887.7
9
35
84 <52>
34
<11> <10>
<53>
<5>
887.7 887.7
887.7
699.5
699.5

H1

H2
<49>
0.0

<50>
699.5

33

OFICINAS H11
<47>
0.0

<48>
699.5

32

<46>
699.5

<45>
<43>
0.00.0
31<44>
30 <42>
29
699.5
699.5


REF: RFE-SPCI-001

RESERVA FRIA ETEN


15/06/2014

ENFRIAMIENTO
LATERAL+HIDRANTE
H3+ESPUMA
(TRAYECTORIA
CRITICA)

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 1
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (&5,7,&$
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR LATERAL+HIDRANTE H3+ESPUMA
SOURCE
STATIC
RESID.
FLOW
AVAIL.
TOTAL
REQ'D
NODE
PRESS.
PRESS. @
PRESS. @ DEMAND
PRESS.
TAG
(PSI)
(PSI)
(GPM)
(PSI)
(GPM)
(PSI)
B_ELECTR

140.0

125.0

2000.0

121.6

2233.3

(N/A)

AGGREGATE FLOW ANALYSIS:


TOTAL
TOTAL
OTHER
TOTAL

FLOW AT SOURCE
HOSE STREAM ALLOWANCE AT SOURCE
HOSE STREAM ALLOWANCES
DISCHARGE FROM ACTIVE SPRINKLERS

2233.3
0.0
909.0
1324.4

NODE ANALYSIS DATA


NODE TAG
1
2
3
4
8
9
10
11
H6
12
13
H7
14
DIL_T
15
16
H8
17
DIL_TPRI
18
H9
19
20
21
H4
22
GEN_AUX
23
24
H3
25
TAN_DIES
26
TALL_ALM
27
28
H10
29
30
H11
31
OFICINAS
32

ELEVATION
(FT)
2.5
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8

NODE TYPE
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - HOSE STREAM
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

PRESSURE
(PSI)
120.7
123.2
123.1
122.6
122.3
121.9
121.2
120.8
120.8
119.6
119.2
119.2
118.4
118.4
117.8
117.4
117.4
116.7
116.7
115.7
115.7
114.6
113.2
113.2
113.2
113.2
113.2
112.9
112.4
112.2
112.1
111.9
112.1
112.1
112.1
112.1
112.1
112.1
112.1
112.1
112.1
112.1
112.1

DISCHARGE
(GPM)
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 500.0
- - - - - - - - - - - - - - - - - - - - - - - - - - -

GPM
GPM
GPM
GPM

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 2
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (&5,7,&$
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR LATERAL+HIDRANTE H3+ESPUMA
NODE ANALYSIS DATA (cont.)
NODE TAG
H2
33
H1
34
H5
50
51
52
53
RISER_TD
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
B12
B13
B14
B15
B16
B17

ELEVATION
(FT)
-3.8
-3.8
-3.8
-3.8
-3.8
1.0
1.0
1.0
1.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0

NODE TYPE
-

PRESSURE
(PSI)
112.1
112.1
112.1
112.1
112.1
109.7
105.2
97.9
97.9
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8

DISCHARGE
(GPM)
-

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 3
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA &5,7,&$
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR LATERAL+HIDRANTE H3+ESPUMA
NODE ANALYSIS DATA (cont.)
NODE TAG
B18
B19
B20
B21
B22
B23
B24
B25
B26
B27
B28
B29
B30
B31
B32
B33
B34
B35
B36
B37
B38
B39
B40
B41
B42
B43
B44
B45
B46
B47
B48
100
101
RISER_ES
102
103
RISER_LD
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126

ELEVATION
(FT)
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
1.0
1.0
70.5
1.0
1.0
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7

NODE TYPE

PRESSURE
(PSI)

DISCHARGE
(GPM)

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - HOSE STREAM
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
62.8
94.0
91.9
57.4
92.2
88.1
57.2
56.7
56.2
55.8
55.4
55.1
54.8
54.6
54.4
54.2
54.1
54.0
54.0
53.9
53.9
53.9
53.9
56.7
56.2
55.8
55.4
55.1
54.8
54.6

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 409.0
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 4
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA &5,7,&$
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR LATERAL+HIDRANTE H3+ESPUMA
NODE ANALYSIS DATA (cont.)
NODE TAG
127
128
129
130
131
132
133
134
135
VK1
VK2
VK3
VK4
VK5
VK6
VK7
VK8
VK9
VK10
VK11
VK12
VK13
VK14
VK15
VK16
VK17
VK18
VK19
VK20
VK21
VK22
VK23
VK24
VK25
VK26
VK27
VK28
VK29
VK30
VK31
VK32
B_ELECTR

ELEVATION
(FT)
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
2.5

NODE TYPE
- - - - - - - - - - - - - - - - - - - - - - - - - - - K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
SOURCE

PRESSURE
(PSI)
54.4
54.2
54.1
54.0
54.0
53.9
53.9
53.9
53.9
53.8
53.8
53.9
53.9
53.9
54.0
54.1
54.2
54.3
54.5
54.7
55.0
55.3
55.7
56.1
56.6
56.6
56.1
55.7
55.3
55.0
54.7
54.5
54.3
54.2
54.1
54.0
53.9
53.9
53.9
53.8
53.8
121.6

DISCHARGE
(GPM)
-

- - - - - - - - - 41.1
41.1
41.1
41.1
41.1
41.1
41.2
41.2
41.3
41.3
41.4
41.5
41.7
41.8
42.0
42.1
42.1
42.0
41.8
41.7
41.5
41.4
41.3
41.3
41.2
41.2
41.1
41.1
41.1
41.1
41.1
41.1
2233.3

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 5
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA &5,7,&$
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR LATERAL+HIDRANTE H3+ESPUMA
PIPE DATA
PIPE TAG
END
NODES

ELEV.
(FT)

NOZ.
(K)

Q(GPM) DIA(IN)
PT
DISC. VEL(FPS) HW(C)
(PSI) (GPM)
FL/FT

Pipe: 1
B_ELECTR
2.5
1
2.5

SRCE
0.0

121.6
120.7

(N/A)
0.0

2.5
-3.8

0.0
0.0

120.7
123.2

0.0
0.0

2
3

Pipe: 3
-3.8
-3.8

0.0
0.0

123.2
123.1

0.0
0.0

3
4

Pipe: 4
-3.8
-3.8

0.0
0.0

123.1
122.6

0.0
0.0

4
8

Pipe: 5
-3.8
-3.8

0.0
0.0

122.6
122.3

0.0
0.0

8
9

Pipe: 10
-3.8
-3.8

0.0
0.0

122.3
121.9

0.0
0.0

9
10

Pipe: 11
-3.8
-3.8

0.0
0.0

121.9
121.2

0.0
0.0

10
11

Pipe: 12
-3.8
-3.8

0.0
0.0

121.2
120.8

0.0
0.0

11
H6

Pipe: 13
-3.8
-3.8

0.0
0.0

120.8
120.8

0.0
0.0

11
12

Pipe: 14
-3.8
-3.8

0.0
0.0

120.8
119.6

0.0
0.0

12
13

Pipe: 15
-3.8
-3.8

0.0
0.0

119.6
119.2

0.0
0.0

13
H7

Pipe: 16
-3.8
-3.8

0.0
0.0

119.2
119.2

0.0
0.0

13
14

Pipe: 17
-3.8
-3.8

0.0
0.0

119.2
118.4

0.0
0.0

Pipe: 18
-3.8
-3.8

0.0
0.0

118.4
118.4

0.0
0.0

Pipe: 19
-3.8
-3.8

0.0
0.0

118.4
117.8

0.0
0.0

Pipe: 2

1
2

14
DIL_T
14
15

LENGTH
(FT)

PRESS.
SUM.
(PSI)

2233.3
6.7

11.650
150
0.004

PL
6.56
FTG ETCG
TL 206.56

PF
PE
PV

0.9
0.0
0.3

2233.3
6.7

11.650
150
0.004

PL
6.23
FTG E
TL 40.23

PF
PE
PV

0.2
2.7
0.3

2233.3
6.7

11.650
150
0.004

PL
6.56
FTG E
TL 40.56

PF
PE
PV

0.2
0.0
0.3

2233.3
6.7

11.650
150
0.004

PL 32.80
FTG T
TL 108.80

PF
PE
PV

0.5
0.0
0.3

2233.3
6.7

11.650
150
0.004

PL
4.80
FTG T
TL 80.80

PF
PE
PV

0.3
0.0
0.3

2233.3
6.7

11.650
150
0.004

PL
4.80
FTG TG
TL 88.80

PF
PE
PV

0.4
0.0
0.3

2233.3
6.7

11.650
150
0.004

PL 121.36
FTG E
TL 155.36

PF
PE
PV

0.7
0.0
0.3

2233.3
6.7

11.650
150
0.004

PL 18.08
FTG T
TL 94.08

PF
PE
PV

0.4
0.0
0.3

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

2233.3
6.7

11.650
150
0.004

PL 186.96
FTG TG
TL 270.96

PF
PE
PV

1.2
0.0
0.3

2233.3
6.7

11.650
150
0.004

PL 26.24
FTG TG
TL 110.24

PF
PE
PV

0.5
0.0
0.3

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

2233.3
6.7

11.650
150
0.004

PL 109.88
FTG T
TL 185.88

PF
PE
PV

0.8
0.0
0.3

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

2233.3
6.7

11.650
150
0.004

PL 96.76
FTG E
TL 130.76

PF
PE
PV

0.6
0.0
0.3

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 6
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (&5,7,&$
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR LATERAL+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)
15
16

Pipe: 20
-3.8
-3.8

0.0
0.0

117.8
117.4

0.0
0.0

16
H8

Pipe: 21
-3.8
-3.8

0.0
0.0

117.4
117.4

0.0
0.0

16
17

Pipe: 22
-3.8
-3.8

0.0
0.0

117.4
116.7

0.0
0.0

Pipe: 23
17
-3.8
DIL_TPRI
-3.8

0.0
0.0

116.7
116.7

0.0
0.0

17
18

Pipe: 24
-3.8
-3.8

0.0
0.0

116.7
115.7

0.0
0.0

18
H9

Pipe: 25
-3.8
-3.8

0.0
0.0

115.7
115.7

0.0
0.0

18
19

Pipe: 26
-3.8
-3.8

0.0
0.0

115.7
114.6

0.0
0.0

19
20

Pipe: 27
-3.8
-3.8

0.0
0.0

114.6
113.2

0.0
0.0

20
21

Pipe: 28
-3.8
-3.8

0.0
0.0

113.2
113.2

0.0
0.0

21
H4

Pipe: 28A
-3.8
-3.8

0.0
0.0

113.2
113.2

0.0
0.0

21
22

Pipe: 29
-3.8
-3.8

0.0
0.0

113.2
113.2

0.0
0.0

Pipe: 29A
22
-3.8
GEN_AUX
-3.8

0.0
0.0

113.2
113.2

0.0
0.0

20
23

Pipe: 31
-3.8
-3.8

0.0
0.0

113.2
112.9

0.0
0.0

23
24

Pipe: 32
-3.8
-3.8

0.0
0.0

112.9
112.4

0.0
0.0

24
H3

Pipe: 33
-3.8
-3.8

0.0
H.S.

112.4
112.2

0.0
500.0

2233.3
6.7

11.650
150
0.004

PL 18.08
FTG T
TL 94.08

PF
PE
PV

0.4
0.0
0.3

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

2233.3
6.7

11.650
150
0.004

PL 100.04
FTG T
TL 176.04

PF
PE
PV

0.8
0.0
0.3

0.0
0.0

9.790
150
0.000

PL 32.80
FTG G
TL 38.80

PF
PE
PV

0.0
0.0
0.0

2233.3
6.7

11.650
150
0.004

PL 151.54
FTG T
TL 227.54

PF
PE
PV

1.0
0.0
0.3

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

2233.3
6.7

11.650
150
0.004

PL 227.96
FTG E
TL 261.96

PF
PE
PV

1.1
0.0
0.3

2233.3
6.7

11.650
150
0.004

PL 232.88
FTG TG
TL 316.88

PF
PE
PV

1.4
0.0
0.3

0.0
0.0

11.650
150
0.000

PL 70.52
FTG TG
TL 154.52

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

11.650
150
0.000

PL 285.36
FTG T
TL 361.36

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

2233.3
6.7

11.650
150
0.004

PL 20.66
FTG EG
TL 62.66

PF
PE
PV

0.3
0.0
0.3

2233.3
6.7

11.650
150
0.004

PL 40.67
FTG T
TL 116.67

PF
PE
PV

0.5
0.0
0.3

500.0
5.5

6.080
150
0.006

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.2
0.0
0.2

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 7
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA &5,7,&$
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR LATERAL+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)
Pipe: 34
-3.8
-3.8

0.0
0.0

112.4
112.1

0.0
0.0

Pipe: 35
25
-3.8
TAN_DIES
-3.8

0.0
0.0

112.1
111.9

0.0
0.0

Pipe: 36
-3.8
-3.8

0.0
0.0

112.1
112.1

0.0
0.0

Pipe: 37
26
-3.8
TALL_ALM
-3.8

0.0
0.0

112.1
112.1

0.0
0.0

26
27

Pipe: 38
-3.8
-3.8

0.0
0.0

112.1
112.1

0.0
0.0

27
28

Pipe: 39
-3.8
-3.8

0.0
0.0

112.1
112.1

0.0
0.0

28
H10

Pipe: 40
-3.8
-3.8

0.0
0.0

112.1
112.1

0.0
0.0

28
29

Pipe: 41
-3.8
-3.8

0.0
0.0

112.1
112.1

0.0
0.0

29
30

Pipe: 42
-3.8
-3.8

0.0
0.0

112.1
112.1

0.0
0.0

30
H11

Pipe: 43
-3.8
-3.8

0.0
0.0

112.1
112.1

0.0
0.0

30
31

Pipe: 44
-3.8
-3.8

0.0
0.0

112.1
112.1

0.0
0.0

Pipe: 45
31
-3.8
OFICINAS
-3.8

0.0
0.0

112.1
112.1

0.0
0.0

31
32

Pipe: 46
-3.8
-3.8

0.0
0.0

112.1
112.1

0.0
0.0

32
H2

Pipe: 47
-3.8
-3.8

0.0
0.0

112.1
112.1

0.0
0.0

32
33

Pipe: 48
-3.8
-3.8

0.0
0.0

112.1
112.1

0.0
0.0

24
25

25
26

1733.3
5.2

11.650
150
0.003

PL 65.90
FTG T
TL 141.90

PF
PE
PV

0.4
0.0
0.2

1733.3
7.4

9.790
150
0.006

PL 14.20
FTG G
TL 20.20

PF
PE
PV

0.1
0.0
0.4

0.0
0.0

11.650
150
0.000

PL 128.25
FTG T
TL 204.25

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

11.650
150
0.000

PL 60.35
FTG E
TL 94.35

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

11.650
150
0.000

PL 48.22
FTG T
TL 124.22

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

11.650
150
0.000

PL 136.12
FTG E
TL 170.12

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

11.650
150
0.000

PL 48.87
FTG T
TL 124.87

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

11.650
150
0.000

PL 30.18
FTG TG
TL 114.18

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

11.650
150
0.000

PL 157.44
FTG TG
TL 241.44

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

11.650
150
0.000

PL 179.90
FTG T
TL 255.90

PF
PE
PV

0.0
0.0
0.0

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 8
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA &5,7,&$
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR LATERAL+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)
33
H1

Pipe: 49
-3.8
-3.8

0.0
0.0

112.1
112.1

0.0
0.0

33
34

Pipe: 50
-3.8
-3.8

0.0
0.0

112.1
112.1

0.0
0.0

34
H5

Pipe: 51
-3.8
-3.8

0.0
0.0

112.1
112.1

0.0
0.0

Pipe: 60
TAN_DIES
-3.8
50
1.0

0.0
0.0

111.9
109.7

0.0
0.0

50
51

Pipe: 61
1.0
1.0

0.0
0.0

109.7
105.2

0.0
0.0

51
52

Pipe: 62
1.0
1.0

0.0
0.0

105.2
97.9

0.0
0.0

52
53

Pipe: 63
1.0
1.0

0.0
0.0

97.9
97.9

0.0
0.0

Pipe: 64
53
1.0
RISER_TD
82.0

0.0
0.0

97.9
62.8

0.0
0.0

Pipe: 65
RISER_TD
82.0
54
82.0

0.0
0.0

62.8
62.8

0.0
0.0

54
55

Pipe: 66
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

55
56

Pipe: 67
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

56
B1

Pipe: 68
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

56
B2

Pipe: 69
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

56
57

Pipe: 70
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

57
B3

Pipe: 71
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

11.650
150
0.000

PL 179.09
FTG T
TL 255.09

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

1733.3
7.4

9.790
150
0.006

PL
4.77
FTG E
TL 32.77

PF
PE
PV

0.2
-2.1
0.4

1733.3
19.2

6.080
120
0.096

PL 32.80
FTG E
TL 46.70

PF
PE
PV

4.5
0.0
2.5

1733.3
19.2

6.080
120
0.096

PL 45.20
FTG T
TL 75.64

PF
PE
PV

7.3
0.0
2.5

0.0
0.0

4.240
120
0.000

PL
9.84
FTG EG
TL 25.06

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

4.240
120
0.000

PL 81.00
FTG T
TL 106.81

PF
0.0
PE -35.1
PV
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG E
TL 13.77

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL 13.45
FTG E
TL 17.71

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
6.99
FTG 2T
TL 24.02

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 9
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA &5,7,&$
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR LATERAL+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)
57
B4

Pipe: 72
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

57
58

Pipe: 73
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

58
B5

Pipe: 74
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

58
B6

Pipe: 75
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

58
59

Pipe: 76
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

59
60

Pipe: 77
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

60
B7

Pipe: 78
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

B7
B8

Pipe: 79
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

60
B9

Pipe: 80
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

B9
B10

Pipe: 81
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

59
61

Pipe: 82
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

61
B11

Pipe: 83
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

61
B12

Pipe: 84
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

61
62

Pipe: 85
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

62
B13

Pipe: 86
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
4.76
FTG T
TL 13.28

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL 14.27
FTG T
TL 22.79

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2ET
TL 11.89

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
9.51
FTG 2E
TL 12.68

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG E2T
TL 14.27

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
9.51
FTG 2E
TL 12.68

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
4.76
FTG 2T
TL 21.79

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 10
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA &5,7,&$
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR LATERAL+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)
B2
B14

Pipe: 87
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

62
63

Pipe: 88
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

63
B15

Pipe: 89
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

63
B16

Pipe: 90
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

63
64

Pipe: 91
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

64
65

Pipe: 92
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

65
66

Pipe: 93
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

66
67

Pipe: 94
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

67
B31

Pipe: 95
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

67
B32

Pipe: 96
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

67
68

Pipe: 97
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

68
B29

Pipe: 98
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

68
B30

Pipe: 99
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

68
69

Pipe: 100
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

69
B27

Pipe: 101
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
6.99
FTG E
TL 11.25

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL 13.45
FTG E
TL 17.71

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG T
TL 18.03

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
6.99
FTG 2T
TL 24.02

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 11
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA &5,7,&$
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR LATERAL+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)
69
B28

Pipe: 102
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

69
70

Pipe: 103
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

70
B25

Pipe: 104
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

70
B26

Pipe: 105
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

70
71

Pipe: 106
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

71
B23

Pipe: 107
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

71
B24

Pipe: 108
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

71
72

Pipe: 109
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

72
B21

Pipe: 110
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

72
B22

Pipe: 111
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

72
73

Pipe: 112
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

73
B19

Pipe: 113
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

73
B20

Pipe: 114
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

73
74

Pipe: 115
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

74
B17

Pipe: 116
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 12
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA &5,7,&$
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR LATERAL+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)
Pipe: 117
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

Pipe: 118
74
82.0
RISER_TD
82.0

0.0
0.0

62.8
62.8

0.0
0.0

Pipe: 119
RISER_TD
82.0
75
82.0

0.0
0.0

62.8
62.8

0.0
0.0

75
76

Pipe: 120
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

76
77

Pipe: 121
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

77
B33

Pipe: 122
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

77
B34

Pipe: 123
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

77
78

Pipe: 124
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

78
B35

Pipe: 125
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

78
B36

Pipe: 126
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

78
79

Pipe: 127
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

79
B37

Pipe: 128
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

79
B38

Pipe: 129
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

79
80

Pipe: 130
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

80
81

Pipe: 131
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

74
B18

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
6.99
FTG T
TL 15.51

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG E
TL 13.77

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL 13.45
FTG E
TL 17.71

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
6.99
FTG 2T
TL 24.02

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
4.76
FTG T
TL 13.28

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL 14.27
FTG T
TL 22.79

PF
PE
PV

0.0
0.0
0.0

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 13
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR LATERAL+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)
81
B39

Pipe: 132
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

B39
B40

Pipe: 133
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

81
B41

Pipe: 134
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

B41
B42

Pipe: 135
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

80
82

Pipe: 136
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

82
B43

Pipe: 137
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

82
B44

Pipe: 138
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

82
83

Pipe: 139
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

83
B45

Pipe: 140
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

83
B46

Pipe: 141
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

83
84

Pipe: 142
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

84
B47

Pipe: 143
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

84
B48

Pipe: 144
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

84
85

Pipe: 145
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

85
86

Pipe: 146
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2ET
TL 11.89

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
9.51
FTG 2E
TL 12.68

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2ET
TL 11.89

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
9.51
FTG 2E
TL 12.68

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
4.76
FTG 2T
TL 21.79

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
6.99
FTG E
TL 11.25

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL 13.45
FTG E
TL 17.71

PF
PE
PV

0.0
0.0
0.0

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 14
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR LATERAL+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)
86
66

Pipe: 147
82.0
82.0

0.0
0.0

62.8
62.8

0.0
0.0

52
100

Pipe: 150
1.0
1.0

0.0
0.0

97.9
94.0

0.0
0.0

100
101

Pipe: 151
1.0
1.0

0.0
0.0

94.0
91.9

0.0
0.0

Pipe: 152
101
1.0
RISER_ES
70.5

0.0
H.S.

91.9
57.4

0.0
409.0

100
102

Pipe: 153
1.0
1.0

0.0
0.0

94.0
92.2

0.0
0.0

102
103

Pipe: 154
1.0
1.0

0.0
0.0

92.2
88.1

0.0
0.0

Pipe: 155
103
1.0
RISER_LD
68.7

0.0
0.0

88.1
57.2

0.0
0.0

Pipe: 156
RISER_LD
68.7
104
68.7

0.0
0.0

57.2
56.7

0.0
0.0

104
VK16

Pipe: 157
68.7
65.4

0.0
5.6

56.7
56.6

0.0
42.1

104
105

Pipe: 158
68.7
68.7

0.0
0.0

56.7
56.2

0.0
0.0

105
VK15

Pipe: 159
68.7
65.4

0.0
5.6

56.2
56.1

0.0
42.0

105
106

Pipe: 160
68.7
68.7

0.0
0.0

56.2
55.8

0.0
0.0

106
VK14

Pipe: 161
68.7
65.4

0.0
5.6

55.8
55.7

0.0
41.8

106
107

Pipe: 162
68.7
68.7

0.0
0.0

55.8
55.4

0.0
0.0

107
VK13

Pipe: 163
68.7
65.4

0.0
5.6

55.4
55.3

0.0
41.7

0.0
0.0

2.000
120
0.000

PL
9.51
FTG T
TL 18.03

PF
PE
PV

0.0
0.0
0.0

1733.3
19.2

6.080
120
0.096

PL 10.17
FTG T
TL 40.61

PF
PE
PV

3.9
0.0
2.5

409.0
9.3

4.240
120
0.038

PL 11.41
FTG ET2G
TL 55.09

PF
PE
PV

2.1
0.0
0.6

409.0
9.3

4.240
120
0.038

PL 69.52
FTG ET2G
TL 113.20

PF
4.4
PE -30.1
PV
0.6

1324.4
14.6

6.080
120
0.058

PL 16.01
FTG E
TL 29.91

PF
PE
PV

1.7
0.0
1.4

1324.4
14.6

6.080
120
0.058

PL 20.04
FTG ET2G
TL 71.00

PF
PE
PV

4.1
0.0
1.4

1324.4
8.5

7.980
120
0.016

PL 67.65
FTG T
TL 100.74

PF
1.6
PE -29.3
PV
0.5

662.2
7.3

6.080
120
0.016

PL
1.93
FTG T
TL 32.37

PF
PE
PV

0.5
0.0
0.4

42.1
7.6

1.500
120
0.090

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

620.1
6.9

6.080
120
0.014

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.5
0.0
0.3

42.0
7.6

1.500
120
0.090

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

578.1
6.4

6.080
120
0.013

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.4
0.0
0.3

41.8
7.6

1.500
120
0.089

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

536.3
5.9

6.080
120
0.011

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.4
0.0
0.2

41.7
7.6

1.500
120
0.089

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 15
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR LATERAL+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)
107
108

Pipe: 164
68.7
68.7

0.0
0.0

55.4
55.1

0.0
0.0

108
VK12

Pipe: 165
68.7
65.4

0.0
5.6

55.1
55.0

0.0
41.5

108
109

Pipe: 166
68.7
68.7

0.0
0.0

55.1
54.8

0.0
0.0

109
VK11

Pipe: 167
68.7
65.4

0.0
5.6

54.8
54.7

0.0
41.4

109
110

Pipe: 168
68.7
68.7

0.0
0.0

54.8
54.6

0.0
0.0

110
VK10

Pipe: 169
68.7
65.4

0.0
5.6

54.6
54.5

0.0
41.3

110
111

Pipe: 170
68.7
68.7

0.0
0.0

54.6
54.4

0.0
0.0

111
VK9

Pipe: 171
68.7
65.4

0.0
5.6

54.4
54.3

0.0
41.3

111
112

Pipe: 172
68.7
68.7

0.0
0.0

54.4
54.2

0.0
0.0

112
VK8

Pipe: 173
68.7
65.4

0.0
5.6

54.2
54.2

0.0
41.2

112
113

Pipe: 174
68.7
68.7

0.0
0.0

54.2
54.1

0.0
0.0

113
VK7

Pipe: 175
68.7
65.4

0.0
5.6

54.1
54.1

0.0
41.2

113
114

Pipe: 176
68.7
68.7

0.0
0.0

54.1
54.0

0.0
0.0

114
VK6

Pipe: 177
68.7
65.4

0.0
5.6

54.0
54.0

0.0
41.1

114
115

Pipe: 178
68.7
68.7

0.0
0.0

54.0
54.0

0.0
0.0

494.7
5.5

6.080
120
0.009

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.3
0.0
0.2

41.5
7.5

1.500
120
0.088

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

453.1
5.0

6.080
120
0.008

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.3
0.0
0.2

41.4
7.5

1.500
120
0.088

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

411.7
4.5

6.080
120
0.007

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.2
0.0
0.1

41.3
7.5

1.500
120
0.087

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

370.3
4.1

6.080
120
0.006

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.2
0.0
0.1

41.3
7.5

1.500
120
0.087

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

329.1
3.6

6.080
120
0.004

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.2
0.0
0.1

41.2
7.5

1.500
120
0.087

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

287.8
3.2

6.080
120
0.003

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.1
0.0
0.1

41.2
7.5

1.500
120
0.087

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

246.7
2.7

6.080
120
0.003

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.1
0.0
0.0

41.1
7.5

1.500
120
0.087

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

205.5
2.3

6.080
120
0.002

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.1
0.0
0.0

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 16
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR LATERAL+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)
115
VK5

Pipe: 179
68.7
65.4

0.0
5.6

54.0
53.9

0.0
41.1

115
116

Pipe: 180
68.7
68.7

0.0
0.0

54.0
53.9

0.0
0.0

116
VK4

Pipe: 181
68.7
65.4

0.0
5.6

53.9
53.9

0.0
41.1

116
117

Pipe: 182
68.7
68.7

0.0
0.0

53.9
53.9

0.0
0.0

117
VK3

Pipe: 183
68.7
65.4

0.0
5.6

53.9
53.9

0.0
41.1

117
118

Pipe: 184
68.7
68.7

0.0
0.0

53.9
53.9

0.0
0.0

118
VK2

Pipe: 185
68.7
65.4

0.0
5.6

53.9
53.8

0.0
41.1

118
119

Pipe: 186
68.7
68.7

0.0
0.0

53.9
53.9

0.0
0.0

119
VK1

Pipe: 187
68.7
65.4

0.0
5.6

53.9
53.8

0.0
41.1

Pipe: 188
RISER_LD
68.7
120
68.7

0.0
0.0

57.2
56.7

0.0
0.0

120
VK17

Pipe: 189
68.7
65.4

0.0
5.6

56.7
56.6

0.0
42.1

120
121

Pipe: 190
68.7
68.7

0.0
0.0

56.7
56.2

0.0
0.0

121
VK18

Pipe: 191
68.7
65.4

0.0
5.6

56.2
56.1

0.0
42.0

121
122

Pipe: 192
68.7
68.7

0.0
0.0

56.2
55.8

0.0
0.0

122
VK19

Pipe: 193
68.7
65.4

0.0
5.6

55.8
55.7

0.0
41.8

41.1
7.5

1.500
120
0.087

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

164.4
1.8

6.080
120
0.001

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

41.1
7.5

1.500
120
0.086

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

123.3
1.4

6.080
120
0.001

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

41.1
7.5

1.500
120
0.086

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

82.2
0.9

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

41.1
7.5

1.500
120
0.086

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

41.1
0.5

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

41.1
7.5

1.500
120
0.086

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

662.2
7.3

6.080
120
0.016

PL
1.93
FTG T
TL 32.37

PF
PE
PV

0.5
0.0
0.4

42.1
7.6

1.500
120
0.090

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

620.1
6.9

6.080
120
0.014

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.5
0.0
0.3

42.0
7.6

1.500
120
0.090

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

578.1
6.4

6.080
120
0.013

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.4
0.0
0.3

41.8
7.6

1.500
120
0.089

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 17
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR LATERAL+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)
122
123

Pipe: 194
68.7
68.7

0.0
0.0

55.8
55.4

0.0
0.0

123
VK20

Pipe: 195
68.7
65.4

0.0
5.6

55.4
55.3

0.0
41.7

123
124

Pipe: 196
68.7
68.7

0.0
0.0

55.4
55.1

0.0
0.0

124
VK21

Pipe: 197
68.7
65.4

0.0
5.6

55.1
55.0

0.0
41.5

124
125

Pipe: 198
68.7
68.7

0.0
0.0

55.1
54.8

0.0
0.0

125
VK22

Pipe: 199
68.7
65.4

0.0
5.6

54.8
54.7

0.0
41.4

125
126

Pipe: 200
68.7
68.7

0.0
0.0

54.8
54.6

0.0
0.0

126
VK23

Pipe: 201
68.7
65.4

0.0
5.6

54.6
54.5

0.0
41.3

126
127

Pipe: 202
68.7
68.7

0.0
0.0

54.6
54.4

0.0
0.0

127
VK24

Pipe: 203
68.7
65.4

0.0
5.6

54.4
54.3

0.0
41.3

127
128

Pipe: 204
68.7
68.7

0.0
0.0

54.4
54.2

0.0
0.0

128
VK25

Pipe: 205
68.7
65.4

0.0
5.6

54.2
54.2

0.0
41.2

128
129

Pipe: 206
68.7
68.7

0.0
0.0

54.2
54.1

0.0
0.0

129
VK26

Pipe: 207
68.7
65.4

0.0
5.6

54.1
54.1

0.0
41.2

129
130

Pipe: 208
68.7
68.7

0.0
0.0

54.1
54.0

0.0
0.0

536.3
5.9

6.080
120
0.011

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.4
0.0
0.2

41.7
7.6

1.500
120
0.089

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

494.7
5.5

6.080
120
0.009

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.3
0.0
0.2

41.5
7.5

1.500
120
0.088

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

453.1
5.0

6.080
120
0.008

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.3
0.0
0.2

41.4
7.5

1.500
120
0.088

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

411.7
4.5

6.080
120
0.007

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.2
0.0
0.1

41.3
7.5

1.500
120
0.087

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

370.3
4.1

6.080
120
0.006

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.2
0.0
0.1

41.3
7.5

1.500
120
0.087

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

329.1
3.6

6.080
120
0.004

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.2
0.0
0.1

41.2
7.5

1.500
120
0.087

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

287.8
3.2

6.080
120
0.003

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.1
0.0
0.1

41.2
7.5

1.500
120
0.087

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

246.7
2.7

6.080
120
0.003

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.1
0.0
0.0

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 18
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR LATERAL+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)
130
VK27

Pipe: 209
68.7
65.4

0.0
5.6

54.0
54.0

0.0
41.1

130
131

Pipe: 210
68.7
68.7

0.0
0.0

54.0
54.0

0.0
0.0

131
VK28

Pipe: 211
68.7
65.4

0.0
5.6

54.0
53.9

0.0
41.1

131
132

Pipe: 212
68.7
68.7

0.0
0.0

54.0
53.9

0.0
0.0

132
VK29

Pipe: 213
68.7
65.4

0.0
5.6

53.9
53.9

0.0
41.1

132
133

Pipe: 214
68.7
68.7

0.0
0.0

53.9
53.9

0.0
0.0

133
VK30

Pipe: 215
68.7
65.4

0.0
5.6

53.9
53.9

0.0
41.1

133
134

Pipe: 216
68.7
68.7

0.0
0.0

53.9
53.9

0.0
0.0

134
VK31

Pipe: 217
68.7
65.4

0.0
5.6

53.9
53.8

0.0
41.1

134
135

Pipe: 218
68.7
68.7

0.0
0.0

53.9
53.9

0.0
0.0

135
VK32

Pipe: 219
68.7
65.4

0.0
5.6

53.9
53.8

0.0
41.1

41.1
7.5

1.500
120
0.087

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

205.5
2.3

6.080
120
0.002

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.1
0.0
0.0

41.1
7.5

1.500
120
0.087

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

164.4
1.8

6.080
120
0.001

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

41.1
7.5

1.500
120
0.086

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

123.3
1.4

6.080
120
0.001

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

41.1
7.5

1.500
120
0.086

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

82.2
0.9

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

41.1
7.5

1.500
120
0.086

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

41.1
0.5

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

41.1
7.5

1.500
120
0.086

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.5
1.4
0.4

NOTES:
(1) Calculations were performed by the HASS computer program

(2) The system has been calculated to provide an average


imbalance at each node of 0.009 gpm and a maximum
imbalance at any node of 0.161 gpm.
(3) Velocity pressures are printed for information only, and are
not used in balancing the system. Maximum water velocity
is 19.2 ft/sec at pipe 61.

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 19
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR LATERAL+HIDRANTE H3+ESPUMA
(4) PIPE FITTINGS TABLE
Pipe Table Name: CUSTOM.PIP
PAGE: *
Diameter
(in)
1.049
1.500
2.067
PAGE: E
Diameter
(in)
4.240
6.080
7.980
9.790
11.650

MATERIAL: S40
HWC: 120
Equivalent Fitting Lengths in Feet
E
T
L
C
B
G
A
Ell
Tee LngEll ChkVlv BfyVlv GatVlv AlmChk
2.00
5.00
2.00
5.00
6.00
1.00 10.00
4.50
9.01
3.00 10.51
9.01
1.50 15.01
5.00 10.00
3.00 11.00
6.00
1.00 10.00
MATERIAL: PVC150
HWC: 150
Equivalent Fitting Lengths in Feet
E
T
L
C
B
G
N
Ell
Tee LngEl ChkVl BfyVl GatVl NPTee
19.00 39.00 12.00 43.00 23.00
4.00 39.00
21.00 46.00 14.00 49.00 15.00
5.00 46.00
26.00 50.00 19.00 64.00 17.00
6.00 50.00
28.00 64.00 20.00 70.00 24.00
6.00 64.00
34.00 76.00 23.00 82.00 27.00
8.00 76.00

D
DPVlv
10.00
15.01
10.00

N
NPTee
5.00
9.01
10.00

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 20
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR LATERAL+HIDRANTE H3+ESPUMA
WATER SUPPLY ANALYSIS

Static: 140.00 psi Resid: 125.00 psi Flow: 2000.0 gpm

180.0

LEGEND
150.0
G
A
G
E
P
R
E
S
S
U
R
E
(
p
s
i
)

120.0

Available pressure
121.60 psi @ 2233.3 gpm

Required pressure
121.60 psi @ 2233.3 gpm

2
1

90.0

60.0

30.0

0.0
-14.7
80012001600 2000

2400
2800
3200
FLOW (GPM)

3600

4000

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 21
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (CRITICA)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR LATERAL+HIDRANTE H3+ESPUMA
SPRINKLER SYSTEM DIAGRAM WITH FLOWPLOT
1516
<24>
<20> <22> 17
2233.3
2233.32233.3
<23>
<21>
0.0
0.0
H8 DIL_TPRI

18

H9

<25>
0.0

<26>
2233.3

19

<19>
2233.3

14<18>
DIL_T
0.0
<27>
2233.3
<17>
2233.3

13<16>
H7
0.0
<15>
12 2233.3

GEN_AUX

22

H4
<29A>
0.0

<28A>
0.0
21 <28>20
0.0 <31>

<29>
0.0

23<32>
2233.3
24 <34>25
27
<36> 26 <38>
2233.3
1733.3 <35> 0.0
0.0
TAN_DIES 1733.3
<33>
<37>
50
500.0 <61>
0.0
<39>
H3
TALL_ALM
0.0
1733.3
102
100
52 <62>
51
<153>
<150>
<63>
<151>
VK9
112
VK8
VK10
VK7
VK11
75
53
54
1324.4
1733.3
1733.3
VK6
<172>
28
VK12
<170>
<173>
<174>
101
VK5
<168>
<119>
<65>
<176>
<154>
VK13
<166>
<178>
VK4
<164>
VK14
<180>
0.0
VK3
<162>
<118>
409.0
<182>
VK15
111
<120>
<66>
110
B17
B18
74
113
VK2
<160>
109
RISER_TD
114
<184>
108
VK16
41.2
<116>
<117>
329.1
370.3
RISER_ES
287.8
115
761324.4
411.7
55246.7
<158>
0.0
0.0
VK1
107
103
453.1
<186>
205.5
116
VK17
494.7
<156>
106
164.4
117
<188>
536.3
0.0
<115>
105
123.3
VK18
0.0
118
<121>
<67>
<190>
578.1
82.2
B33
B34
77
B19
B20
73
104
B1
56
B20.0
0.0
0.0
620.1
119
VK19
RISER_LD
<192>
<122>
<123>
<113>
<114>
<68>
<69>
41.1
120
662.2
<40>
VK20 <194>
0.0
121
0.0
0.0
620.1
<124>
<70>
<112>
VK21
<196>
122
B40
B35
B36
78
B21
B22
72
B3
57
B
B8
4
578.1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
<125>
<126>
<110>
<111>
<71>
<72>
VK22
<198>
123
536.3
0.0
0.0
0.0
VK23
124
<200>
494.7
<127>
<73>
<133>
<109>
<79>
H10
B39
B37
B38
79
B23
B24
71
B5
58
B
B
6
7
0.0
0.0
0.0
0.0
0.0
0.0
VK24
125
<202>
453.1
<128>
<129>
<107>
<108>
<74>
<75>
<87>
126
VK25
<132>
<130>
<76>
<78>
<204>
411.7
81
80
59
60
0.0
0.0
0.0
0.0
0.0
<131>
<77>
<106>
127
VK26
<206>
370.3
<134>
<136>
<82>
<80>
B41
B43
B44
82
B25
B26
70
B11
B12
61
B9
0.0
0.0
0.0
0.0
0.0
0.0
0.0
<137>
<138>
<104>
<105>
<83>
<84>
VK270.0
128
0.0
0.0
0.0
0.0
<208>
329.1
0.0
0.0
VK28
129
<210>
287.8
<135>
<139>
<85>
<81>
<103>
0.0
0.0
0.0
0.0
B42
B45
B46
83
B27
B28
69
B13
B14
62
B10
VK29
0.0
0.0
0.0
0.0
0.0
0.0
<212>
130
246.7
<140>
<141>
<101>
<102>
<86>
VK30
<214>
131
205.5
0.0
0.0
0.0
0.0
0.0
VK31
<142>
<88>
<100>
<216>
132
164.4
VK32
B47
B48
84
B29
B30
68
B15
B16
63
0.0
0.0
0.0
0.0
0.0
<218>
133
<143>
<144>
<98>
<99>
<89>
<90>
123.3
134
0.0
0.0
0.0
82.2
<145>
<91>
<97>
85
64
<41>
135
41.1
B31
B32
67
0.0
0.0
0.0
0.0
0.0
0.0
<95>
<96>
0.0
0.0
<146>
<92>
0.0
0.0
<94>
86
66
65
<147>
<93>
0.0
0.0
0.0
0.0
0.0
0.0
0.0

<14>
2233.3

B_ELECTR<1>
23
H5
<3>
1
2233.3
2233.3
11<13>
H6
<4>
<51>
0.0
<12>
2233.3 0.0
10 2233.3
9<5>
84
34
<11> <10>
2233.3 2233.3
2233.3

H1

<50>
0.0

33

H2
<49>
0.0

<48>
0.0

32

OFICINAS H11
<47>
0.0

<46>
0.0

<45>
<43>
0.00.0
31<44>
30 <42>
29
0.0 0.0


REF: RFE-SPCI-001

RESERVA FRIA ETEN


15/06/2014

ENFRIAMIENTO
LATERAL+HIDRANTE
H3+ESPUMA
(TRAYECTORIA
NORMAL)

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 1
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
SOURCE
STATIC
RESID.
FLOW
AVAIL.
TOTAL
REQ'D
NODE
PRESS.
PRESS. @
PRESS. @ DEMAND
PRESS.
TAG
(PSI)
(PSI)
(GPM)
(PSI)
(GPM)
(PSI)
B_ELECTR

140.0

125.0

2000.0

120.6

2297.9

(N/A)

AGGREGATE FLOW ANALYSIS:

TOTAL
TOTAL
OTHER
TOTAL

FLOW AT SOURCE
HOSE STREAM ALLOWANCE AT SOURCE
HOSE STREAM ALLOWANCES
DISCHARGE FROM ACTIVE SPRINKLERS

2297.9
0.0
909.0
1389.0

NODE ANALYSIS DATA


NODE TAG

1
2
3
4
8
9
10
11
H6
12
13
H7
14
DIL_T
15
16
H8
17
DIL_TPRI
18
H9
19
20
21
H4
22
GEN_AUX
23
24
H3
25
TAN_DIES
26
TALL_ALM
27
28
H10
29
30
H11
31
OFICINAS
32

ELEVATION
(FT)
2.5
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8

NODE TYPE

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - HOSE STREAM
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

PRESSURE
(PSI)
119.7
122.2
122.0
121.5
121.4
121.3
121.0
120.9
120.9
120.5
120.4
120.4
120.4
120.4
120.3
120.3
120.3
120.3
120.3
120.2
120.2
120.1
120.1
120.2
120.2
120.4
120.4
120.0
119.8
119.5
119.7
119.6
119.9
119.9
120.0
120.1
120.1
120.3
120.4
120.4
120.5
120.5
120.8

DISCHARGE
(GPM)
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 500.0
- - - - - - - - - - - - - - - - - - - - - - - - - - -

GPM
GPM
GPM
GPM

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 2
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
NODE ANALYSIS DATA (cont.)
NODE TAG

H2
33
H1
34
H5
35
50
51
52
53
RISER_TD
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
B12
B13
B14
B15
B16

ELEVATION
(FT)
-3.8
-3.8
-3.8
-3.8
-3.8
-3.8
1.0
1.0
1.0
1.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0

NODE TYPE

PRESSURE
(PSI)
120.8
121.0
121.0
121.3
121.3
121.4
117.3
112.5
104.7
104.7
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6

DISCHARGE
(GPM)
-

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 3
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
NODE ANALYSIS DATA (cont.)
NODE TAG

B17
B18
B19
B20
B21
B22
B23
B24
B25
B26
B27
B28
B29
B30
B31
B32
B33
B34
B35
B36
B37
B38
B39
B40
B41
B42
B43
B44
B45
B46
B47
B48
100
101
RISER_ES
102
103
RISER_LD
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125

ELEVATION
(FT)
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
82.0
1.0
1.0
70.5
1.0
1.0
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7

NODE TYPE

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - HOSE STREAM
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

PRESSURE
(PSI)
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
69.6
100.5
98.4
63.9
98.6
94.1
63.1
62.5
61.9
61.5
61.1
60.7
60.4
60.2
59.9
59.8
59.6
59.6
59.5
59.4
59.4
59.4
59.4
62.5
61.9
61.5
61.1
60.7
60.4

DISCHARGE
(GPM)
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 409.0
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 4
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
NODE ANALYSIS DATA (cont.)
NODE TAG

126
127
128
129
130
131
132
133
134
135
VK1
VK2
VK3
VK4
VK5
VK6
VK7
VK8
VK9
VK10
VK11
VK12
VK13
VK14
VK15
VK16
VK17
VK18
VK19
VK20
VK21
VK22
VK23
VK24
VK25
VK26
VK27
VK28
VK29
VK30
VK31
VK32
B_ELECTR

ELEVATION
(FT)
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
68.7
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
65.4
2.5

NODE TYPE

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
K= 5.60
SOURCE

PRESSURE
(PSI)
60.2
59.9
59.8
59.6
59.6
59.5
59.4
59.4
59.4
59.4
59.2
59.2
59.2
59.3
59.3
59.4
59.5
59.6
59.8
60.0
60.2
60.5
60.9
61.3
61.7
62.2
62.2
61.7
61.3
60.9
60.5
60.2
60.0
59.8
59.6
59.5
59.4
59.3
59.3
59.2
59.2
59.2
120.6

DISCHARGE
(GPM)
-

- - - - - - - - - - 43.1
43.1
43.1
43.1
43.1
43.2
43.2
43.2
43.3
43.4
43.5
43.6
43.7
43.8
44.0
44.2
44.2
44.0
43.8
43.7
43.6
43.5
43.4
43.3
43.2
43.2
43.2
43.1
43.1
43.1
43.1
43.1
2297.9

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 5
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE DATA
PIPE TAG
END
NODES

ELEV.
(FT)

NOZ.
(K)

Q(GPM) DIA(IN)
PT
DISC. VEL(FPS) HW(C)
(PSI) (GPM)
FL/FT

Pipe: 1
B_ELECTR
2.5
1
2.5

SRCE
0.0

120.6
119.7

(N/A)
0.0

11.650
150
0.005

PL
6.56
FTG ETCG
TL 206.56

PF
PE
PV

0.9
0.0
0.3

2297.9
6.9

11.650
150
0.005

PL
6.23
FTG E
TL 40.23

PF
PE
PV

0.2
2.7
0.3

2297.9
6.9

11.650
150
0.005

PL
6.56
FTG E
TL 40.56

PF
PE
PV

0.2
0.0
0.3

2297.9
6.9

11.650
150
0.005

PL 32.80
FTG T
TL 108.80

PF
PE
PV

0.5
0.0
0.3

1278.4
3.8

11.650
150
0.002

PL
4.80
FTG T
TL 80.80

PF
PE
PV

0.1
0.0
0.1

1278.4
3.8

11.650
150
0.002

PL
4.80
FTG TG
TL 88.80

PF
PE
PV

0.1
0.0
0.1

1278.4
3.8

11.650
150
0.002

PL 121.36
FTG E
TL 155.36

PF
PE
PV

0.2
0.0
0.1

1278.4
3.8

11.650
150
0.002

PL 18.08
FTG T
TL 94.08

PF
PE
PV

0.1
0.0
0.1

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

1278.4
3.8

11.650
150
0.002

PL 186.96
FTG TG
TL 270.96

PF
PE
PV

0.4
0.0
0.1

500.7
1.5

11.650
150
0.000

PL 26.24
FTG TG
TL 110.24

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

500.7
1.5

11.650
150
0.000

PL 109.88
FTG T
TL 185.88

PF
PE
PV

0.1
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

500.7
1.5

11.650
150
0.000

PL 96.76
FTG E
TL 130.76

PF
PE
PV

0.0
0.0
0.0

Pipe: 2
2.5
-3.8

0.0
0.0

119.7
122.2

0.0
0.0

2
3

Pipe: 3
-3.8
-3.8

0.0
0.0

122.2
122.0

0.0
0.0

3
4

Pipe: 4
-3.8
-3.8

0.0
0.0

122.0
121.5

0.0
0.0

4
8

Pipe: 5
-3.8
-3.8

0.0
0.0

121.5
121.4

0.0
0.0

8
9

Pipe: 10
-3.8
-3.8

0.0
0.0

121.4
121.3

0.0
0.0

9
10

Pipe: 11
-3.8
-3.8

0.0
0.0

121.3
121.0

0.0
0.0

10
11

Pipe: 12
-3.8
-3.8

0.0
0.0

121.0
120.9

0.0
0.0

11
H6

Pipe: 13
-3.8
-3.8

0.0
0.0

120.9
120.9

0.0
0.0

11
12

Pipe: 14
-3.8
-3.8

0.0
0.0

120.9
120.5

0.0
0.0

12
13

Pipe: 15
-3.8
-3.8

0.0
0.0

120.5
120.4

0.0
0.0

13
H7

Pipe: 16
-3.8
-3.8

0.0
0.0

120.4
120.4

0.0
0.0

13
14

Pipe: 17
-3.8
-3.8

0.0
0.0

120.4
120.4

0.0
0.0

Pipe: 18
-3.8
-3.8

0.0
0.0

120.4
120.4

0.0
0.0

Pipe: 19
-3.8
-3.8

0.0
0.0

120.4
120.3

0.0
0.0

14
15

PRESS.
SUM.
(PSI)

2297.9
6.9

1
2

14
DIL_T

LENGTH
(FT)

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 6
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)

15
16

Pipe: 20
-3.8
-3.8

0.0
0.0

120.3
120.3

0.0
0.0

16
H8

Pipe: 21
-3.8
-3.8

0.0
0.0

120.3
120.3

0.0
0.0

16
17

Pipe: 22
-3.8
-3.8

0.0
0.0

120.3
120.3

0.0
0.0

Pipe: 23
17
-3.8
DIL_TPRI
-3.8

0.0
0.0

120.3
120.3

0.0
0.0

17
18

Pipe: 24
-3.8
-3.8

0.0
0.0

120.3
120.2

0.0
0.0

18
H9

Pipe: 25
-3.8
-3.8

0.0
0.0

120.2
120.2

0.0
0.0

18
19

Pipe: 26
-3.8
-3.8

0.0
0.0

120.2
120.1

0.0
0.0

19
20

Pipe: 27
-3.8
-3.8

0.0
0.0

120.1
120.1

0.0
0.0

20
21

Pipe: 28
-3.8
-3.8

0.0
0.0

120.1
120.2

0.0
0.0

21
H4

Pipe: 28A
-3.8
-3.8

0.0
0.0

120.2
120.2

0.0
0.0

21
22

Pipe: 29
-3.8
-3.8

0.0
0.0

120.2
120.4

0.0
0.0

Pipe: 29A
22
-3.8
GEN_AUX
-3.8

0.0
0.0

120.4
120.4

0.0
0.0

22
12

Pipe: 30
-3.8
-3.8

0.0
0.0

120.4
120.5

0.0
0.0

20
23

Pipe: 31
-3.8
-3.8

0.0
0.0

120.1
120.0

0.0
0.0

23
24

Pipe: 32
-3.8
-3.8

0.0
0.0

120.0
119.8

0.0
0.0

500.7
1.5

11.650
150
0.000

PL 18.08
FTG T
TL 94.08

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

500.7
1.5

11.650
150
0.000

PL 100.04
FTG T
TL 176.04

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

9.790
150
0.000

PL 32.80
FTG G
TL 38.80

PF
PE
PV

0.0
0.0
0.0

500.7
1.5

11.650
150
0.000

PL 151.54
FTG T
TL 227.54

PF
PE
PV

0.1
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

500.7
1.5

11.650
150
0.000

PL 227.96
FTG E
TL 261.96

PF
PE
PV

0.1
0.0
0.0

500.7
1.5

11.650
150
0.000

PL 232.88
FTG TG
TL 316.88

PF
PE
PV

0.1
0.0
0.0

-777.7
2.3

11.650
150
0.001

PL 70.52
FTG TG
TL 154.52

PF
PE
PV

0.1
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

-777.7
2.3

11.650
150
0.001

PL 285.36
FTG T
TL 361.36

PF
PE
PV

0.2
0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

-777.7
2.3

11.650
150
0.001

PL 141.70
FTG G
TL 149.70

PF
PE
PV

0.1
0.0
0.0

1278.4
3.8

11.650
150
0.002

PL 20.66
FTG EG
TL 62.66

PF
PE
PV

0.1
0.0
0.1

1278.4
3.8

11.650
150
0.002

PL 40.67
FTG T
TL 116.67

PF
PE
PV

0.2
0.0
0.1

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 7
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)

24
H3

Pipe: 33
-3.8
-3.8

0.0
H.S.

119.8
119.5

0.0
500.0

500.0
5.5

6.080
150
0.006

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.2
0.0
0.2

24
25

Pipe: 34
-3.8
-3.8

0.0
0.0

119.8
119.7

0.0
0.0

778.4
2.3

11.650
150
0.001

PL 65.90
FTG T
TL 141.90

PF
PE
PV

0.1
0.0
0.0

Pipe: 35
25
-3.8
TAN_DIES
-3.8

0.0
0.0

119.7
119.6

0.0
0.0

1797.9
7.7

9.790
150
0.007

PL 14.20
FTG G
TL 20.20

PF
PE
PV

0.1
0.0
0.4

Pipe: 36
-3.8
-3.8

0.0
0.0

119.7
119.9

-1019.5
0.0
3.1
0.0

11.650
150
0.001

PL 128.25
FTG T
TL 204.25

PF
PE
PV

0.2
0.0
0.1

Pipe: 37
26
-3.8
TALL_ALM
-3.8

0.0
0.0

119.9
119.9

0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

26
27

Pipe: 38
-3.8
-3.8

0.0
0.0

119.9
120.0

-1019.5
0.0
3.1
0.0

11.650
150
0.001

PL 60.35
FTG E
TL 94.35

PF
PE
PV

0.1
0.0
0.1

27
28

Pipe: 39
-3.8
-3.8

0.0
0.0

120.0
120.1

-1019.5
0.0
3.1
0.0

11.650
150
0.001

PL 48.22
FTG T
TL 124.22

PF
PE
PV

0.1
0.0
0.1

28
H10

Pipe: 40
-3.8
-3.8

0.0
0.0

120.1
120.1

0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

28
29

Pipe: 41
-3.8
-3.8

0.0
0.0

120.1
120.3

-1019.5
0.0
3.1
0.0

11.650
150
0.001

PL 136.12
FTG E
TL 170.12

PF
PE
PV

0.2
0.0
0.1

29
30

Pipe: 42
-3.8
-3.8

0.0
0.0

120.3
120.4

-1019.5
0.0
3.1
0.0

11.650
150
0.001

PL 48.87
FTG T
TL 124.87

PF
PE
PV

0.1
0.0
0.1

30
H11

Pipe: 43
-3.8
-3.8

0.0
0.0

120.4
120.4

0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

30
31

Pipe: 44
-3.8
-3.8

0.0
0.0

120.4
120.5

-1019.5
0.0
3.1
0.0

11.650
150
0.001

PL 30.18
FTG TG
TL 114.18

PF
PE
PV

0.1
0.0
0.1

Pipe: 45
31
-3.8
OFICINAS
-3.8

0.0
0.0

120.5
120.5

0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

31
32

Pipe: 46
-3.8
-3.8

0.0
0.0

120.5
120.8

-1019.5
0.0
3.1
0.0

11.650
150
0.001

PL 157.44
FTG TG
TL 241.44

PF
PE
PV

0.2
0.0
0.1

32
H2

Pipe: 47
-3.8
-3.8

0.0
0.0

120.8
120.8

0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

25
26

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 8
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)

32
33

Pipe: 48
-3.8
-3.8

0.0
0.0

120.8
121.0

-1019.5
0.0
3.1
0.0

11.650
150
0.001

PL 179.90
FTG T
TL 255.90

PF
PE
PV

0.3
0.0
0.1

33
H1

Pipe: 49
-3.8
-3.8

0.0
0.0

121.0
121.0

0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

33
34

Pipe: 50
-3.8
-3.8

0.0
0.0

121.0
121.3

-1019.5
0.0
3.1
0.0

11.650
150
0.001

PL 179.09
FTG T
TL 255.09

PF
PE
PV

0.3
0.0
0.1

34
H5

Pipe: 51
-3.8
-3.8

0.0
0.0

121.3
121.3

0.0
0.0

0.0
0.0

6.080
150
0.000

PL 32.80
FTG G
TL 37.80

PF
PE
PV

0.0
0.0
0.0

34
35

Pipe: 52
-3.8
-3.8

0.0
0.0

121.3
121.4

-1019.5
0.0
3.1
0.0

11.650
150
0.001

PL 61.66
FTG T
TL 137.66

PF
PE
PV

0.1
0.0
0.1

4
35

Pipe: 53
-3.8
-3.8

0.0
0.0

121.5
121.4

0.0
0.0

1019.5
3.1

11.650
150
0.001

PL
4.80
FTG TG
TL 88.80

PF
PE
PV

0.1
0.0
0.1

Pipe: 60
TAN_DIES
-3.8
50
1.0

0.0
0.0

119.6
117.3

0.0
0.0

1797.9
7.7

9.790
150
0.007

PL
4.77
FTG E
TL 32.77

PF
PE
PV

0.2
-2.1
0.4

50
51

Pipe: 61
1.0
1.0

0.0
0.0

117.3
112.5

0.0
0.0

1797.9
19.9

6.080
120
0.103

PL 32.80
FTG E
TL 46.70

PF
PE
PV

4.8
0.0
2.7

51
52

Pipe: 62
1.0
1.0

0.0
0.0

112.5
104.7

0.0
0.0

1797.9
19.9

6.080
120
0.103

PL 45.20
FTG T
TL 75.64

PF
PE
PV

7.8
0.0
2.7

52
53

Pipe: 63
1.0
1.0

0.0
0.0

104.7
104.7

0.0
0.0

0.0
0.0

4.240
120
0.000

PL
9.84
FTG EG
TL 25.06

PF
PE
PV

0.0
0.0
0.0

Pipe: 64
53
1.0
RISER_TD
82.0

0.0
0.0

104.7
69.6

0.0
0.0

0.0
0.0

4.240
120
0.000

PL 81.00
FTG T
TL 106.81

PF
0.0
PE -35.1
PV
0.0

Pipe: 65
RISER_TD
82.0
54
82.0

0.0
0.0

69.6
69.6

0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG E
TL 13.77

PF
PE
PV

0.0
0.0
0.0

54
55

Pipe: 66
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

0.0
0.0

2.000
120
0.000

PL 13.45
FTG E
TL 17.71

PF
PE
PV

0.0
0.0
0.0

55
56

Pipe: 67
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

0.0
0.0

2.000
120
0.000

PL
6.99
FTG 2T
TL 24.02

PF
PE
PV

0.0
0.0
0.0

56
B1

Pipe: 68
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 9
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)

56
B2

Pipe: 69
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

56
57

Pipe: 70
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

57
B3

Pipe: 71
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

57
B4

Pipe: 72
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

57
58

Pipe: 73
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

58
B5

Pipe: 74
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

58
B6

Pipe: 75
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

58
59

Pipe: 76
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

59
60

Pipe: 77
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

60
B7

Pipe: 78
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

B7
B8

Pipe: 79
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

60
B9

Pipe: 80
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

B9
B10

Pipe: 81
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

59
61

Pipe: 82
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

61
B11

Pipe: 83
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
4.76
FTG T
TL 13.28

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL 14.27
FTG T
TL 22.79

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2ET
TL 11.89

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
9.51
FTG 2E
TL 12.68

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG E2T
TL 14.27

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
9.51
FTG 2E
TL 12.68

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
4.76
FTG 2T
TL 21.79

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 10
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)

61
B12

Pipe: 84
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

61
62

Pipe: 85
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

62
B13

Pipe: 86
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

B2
B14

Pipe: 87
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

62
63

Pipe: 88
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

63
B15

Pipe: 89
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

63
B16

Pipe: 90
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

63
64

Pipe: 91
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

64
65

Pipe: 92
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

65
66

Pipe: 93
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

66
67

Pipe: 94
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

67
B31

Pipe: 95
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

67
B32

Pipe: 96
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

67
68

Pipe: 97
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

68
B29

Pipe: 98
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
6.99
FTG E
TL 11.25

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL 13.45
FTG E
TL 17.71

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG T
TL 18.03

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
6.99
FTG 2T
TL 24.02

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 11
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)

68
B30

Pipe: 99
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

68
69

Pipe: 100
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

69
B27

Pipe: 101
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

69
B28

Pipe: 102
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

69
70

Pipe: 103
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

70
B25

Pipe: 104
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

70
B26

Pipe: 105
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

70
71

Pipe: 106
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

71
B23

Pipe: 107
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

71
B24

Pipe: 108
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

71
72

Pipe: 109
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

72
B21

Pipe: 110
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

72
B22

Pipe: 111
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

72
73

Pipe: 112
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

73
B19

Pipe: 113
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 12
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)

73
B20

Pipe: 114
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

73
74

Pipe: 115
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

74
B17

Pipe: 116
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

74
B18

Pipe: 117
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

Pipe: 118
74
82.0
RISER_TD
82.0

0.0
0.0

69.6
69.6

0.0
0.0

Pipe: 119
RISER_TD
82.0
75
82.0

0.0
0.0

69.6
69.6

0.0
0.0

75
76

Pipe: 120
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

76
77

Pipe: 121
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

77
B33

Pipe: 122
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

77
B34

Pipe: 123
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

77
78

Pipe: 124
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

78
B35

Pipe: 125
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

78
B36

Pipe: 126
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

78
79

Pipe: 127
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

79
B37

Pipe: 128
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
6.99
FTG T
TL 15.51

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG E
TL 13.77

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL 13.45
FTG E
TL 17.71

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
6.99
FTG 2T
TL 24.02

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 13
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)

79
B38

Pipe: 129
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

79
80

Pipe: 130
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

80
81

Pipe: 131
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

81
B39

Pipe: 132
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

B39
B40

Pipe: 133
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

81
B41

Pipe: 134
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

B41
B42

Pipe: 135
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

80
82

Pipe: 136
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

82
B43

Pipe: 137
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

82
B44

Pipe: 138
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

82
83

Pipe: 139
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

83
B45

Pipe: 140
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

83
B46

Pipe: 141
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

83
84

Pipe: 142
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

84
B47

Pipe: 143
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
4.76
FTG T
TL 13.28

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL 14.27
FTG T
TL 22.79

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2ET
TL 11.89

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
9.51
FTG 2E
TL 12.68

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2ET
TL 11.89

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
9.51
FTG 2E
TL 12.68

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
4.76
FTG 2T
TL 21.79

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG 2T
TL 26.54

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 14
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)

84
B48

Pipe: 144
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

84
85

Pipe: 145
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

85
86

Pipe: 146
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

86
66

Pipe: 147
82.0
82.0

0.0
0.0

69.6
69.6

0.0
0.0

52
100

Pipe: 150
1.0
1.0

0.0
0.0

104.7
100.5

0.0
0.0

100
101

Pipe: 151
1.0
1.0

0.0
0.0

100.5
98.4

0.0
0.0

Pipe: 152
101
1.0
RISER_ES
70.5

0.0
H.S.

98.4
63.9

0.0
409.0

100
102

Pipe: 153
1.0
1.0

0.0
0.0

100.5
98.6

0.0
0.0

102
103

Pipe: 154
1.0
1.0

0.0
0.0

98.6
94.1

0.0
0.0

Pipe: 155
103
1.0
RISER_LD
68.7

0.0
0.0

94.1
63.1

0.0
0.0

Pipe: 156
RISER_LD
68.7
104
68.7

0.0
0.0

63.1
62.5

0.0
0.0

104
VK16

Pipe: 157
68.7
65.4

0.0
5.6

62.5
62.2

0.0
44.2

104
105

Pipe: 158
68.7
68.7

0.0
0.0

62.5
61.9

0.0
0.0

105
VK15

Pipe: 159
68.7
65.4

0.0
5.6

61.9
61.7

0.0
44.0

105
106

Pipe: 160
68.7
68.7

0.0
0.0

61.9
61.5

0.0
0.0

0.0
0.0

1.000
120
0.000

PL
4.76
FTG 2E
TL
7.93

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
6.99
FTG E
TL 11.25

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL 13.45
FTG E
TL 17.71

PF
PE
PV

0.0
0.0
0.0

0.0
0.0

2.000
120
0.000

PL
9.51
FTG T
TL 18.03

PF
PE
PV

0.0
0.0
0.0

1797.9
19.9

6.080
120
0.103

PL 10.17
FTG T
TL 40.61

PF
PE
PV

4.2
0.0
2.7

409.0
9.3

4.240
120
0.038

PL 11.41
FTG ET2G
TL 55.09

PF
PE
PV

2.1
0.0
0.6

409.0
9.3

4.240
120
0.038

PL 69.52
FTG ET2G
TL 113.20

PF
4.4
PE -30.1
PV
0.6

1389.0
15.3

6.080
120
0.064

PL 16.01
FTG E
TL 29.91

PF
PE
PV

1.9
0.0
1.6

1389.0
15.3

6.080
120
0.064

PL 20.04
FTG ET2G
TL 71.00

PF
PE
PV

4.5
0.0
1.6

1389.0
8.9

7.980
120
0.017

PL 67.65
FTG T
TL 100.74

PF
1.7
PE -29.3
PV
0.5

694.5
7.7

6.080
120
0.018

PL
1.93
FTG T
TL 32.37

PF
PE
PV

0.6
0.0
0.4

44.2
8.0

1.500
120
0.099

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.7
1.4
0.4

650.3
7.2

6.080
120
0.016

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.5
0.0
0.3

44.0
8.0

1.500
120
0.098

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

606.3
6.7

6.080
120
0.014

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.5
0.0
0.3

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 15
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)

106
VK14

Pipe: 161
68.7
65.4

0.0
5.6

61.5
61.3

0.0
43.8

106
107

Pipe: 162
68.7
68.7

0.0
0.0

61.5
61.1

0.0
0.0

107
VK13

Pipe: 163
68.7
65.4

0.0
5.6

61.1
60.9

0.0
43.7

107
108

Pipe: 164
68.7
68.7

0.0
0.0

61.1
60.7

0.0
0.0

108
VK12

Pipe: 165
68.7
65.4

0.0
5.6

60.7
60.5

0.0
43.6

108
109

Pipe: 166
68.7
68.7

0.0
0.0

60.7
60.4

0.0
0.0

109
VK11

Pipe: 167
68.7
65.4

0.0
5.6

60.4
60.2

0.0
43.5

109
110

Pipe: 168
68.7
68.7

0.0
0.0

60.4
60.2

0.0
0.0

110
VK10

Pipe: 169
68.7
65.4

0.0
5.6

60.2
60.0

0.0
43.4

110
111

Pipe: 170
68.7
68.7

0.0
0.0

60.2
59.9

0.0
0.0

111
VK9

Pipe: 171
68.7
65.4

0.0
5.6

59.9
59.8

0.0
43.3

111
112

Pipe: 172
68.7
68.7

0.0
0.0

59.9
59.8

0.0
0.0

112
VK8

Pipe: 173
68.7
65.4

0.0
5.6

59.8
59.6

0.0
43.2

112
113

Pipe: 174
68.7
68.7

0.0
0.0

59.8
59.6

0.0
0.0

113
VK7

Pipe: 175
68.7
65.4

0.0
5.6

59.6
59.5

0.0
43.2

43.8
8.0

1.500
120
0.097

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

562.5
6.2

6.080
120
0.012

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.4
0.0
0.3

43.7
7.9

1.500
120
0.097

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

518.8
5.7

6.080
120
0.010

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.4
0.0
0.2

43.6
7.9

1.500
120
0.096

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

475.2
5.3

6.080
120
0.009

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.3
0.0
0.2

43.5
7.9

1.500
120
0.096

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

431.8
4.8

6.080
120
0.007

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.3
0.0
0.2

43.4
7.9

1.500
120
0.095

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

388.4
4.3

6.080
120
0.006

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.2
0.0
0.1

43.3
7.9

1.500
120
0.095

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

345.1
3.8

6.080
120
0.005

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.2
0.0
0.1

43.2
7.8

1.500
120
0.095

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

301.9
3.3

6.080
120
0.004

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.1
0.0
0.1

43.2
7.8

1.500
120
0.095

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 16
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)

113
114

Pipe: 176
68.7
68.7

0.0
0.0

59.6
59.6

0.0
0.0

114
VK6

Pipe: 177
68.7
65.4

0.0
5.6

59.6
59.4

0.0
43.2

114
115

Pipe: 178
68.7
68.7

0.0
0.0

59.6
59.5

0.0
0.0

115
VK5

Pipe: 179
68.7
65.4

0.0
5.6

59.5
59.3

0.0
43.1

115
116

Pipe: 180
68.7
68.7

0.0
0.0

59.5
59.4

0.0
0.0

116
VK4

Pipe: 181
68.7
65.4

0.0
5.6

59.4
59.3

0.0
43.1

116
117

Pipe: 182
68.7
68.7

0.0
0.0

59.4
59.4

0.0
0.0

117
VK3

Pipe: 183
68.7
65.4

0.0
5.6

59.4
59.2

0.0
43.1

117
118

Pipe: 184
68.7
68.7

0.0
0.0

59.4
59.4

0.0
0.0

118
VK2

Pipe: 185
68.7
65.4

0.0
5.6

59.4
59.2

0.0
43.1

118
119

Pipe: 186
68.7
68.7

0.0
0.0

59.4
59.4

0.0
0.0

119
VK1

Pipe: 187
68.7
65.4

0.0
5.6

59.4
59.2

0.0
43.1

Pipe: 188
RISER_LD
68.7
120
68.7

0.0
0.0

63.1
62.5

0.0
0.0

120
VK17

Pipe: 189
68.7
65.4

0.0
5.6

62.5
62.2

0.0
44.2

120
121

Pipe: 190
68.7
68.7

0.0
0.0

62.5
61.9

0.0
0.0

258.7
2.9

6.080
120
0.003

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.1
0.0
0.1

43.2
7.8

1.500
120
0.095

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

215.5
2.4

6.080
120
0.002

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.1
0.0
0.0

43.1
7.8

1.500
120
0.094

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

172.4
1.9

6.080
120
0.001

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

43.1
7.8

1.500
120
0.094

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

129.3
1.4

6.080
120
0.001

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

43.1
7.8

1.500
120
0.094

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

86.2
1.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

43.1
7.8

1.500
120
0.094

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

43.1
0.5

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

43.1
7.8

1.500
120
0.094

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

694.5
7.7

6.080
120
0.018

PL
1.93
FTG T
TL 32.37

PF
PE
PV

0.6
0.0
0.4

44.2
8.0

1.500
120
0.099

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.7
1.4
0.4

650.3
7.2

6.080
120
0.016

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.5
0.0
0.3

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 17
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)

121
VK18

Pipe: 191
68.7
65.4

0.0
5.6

61.9
61.7

0.0
44.0

121
122

Pipe: 192
68.7
68.7

0.0
0.0

61.9
61.5

0.0
0.0

122
VK19

Pipe: 193
68.7
65.4

0.0
5.6

61.5
61.3

0.0
43.8

122
123

Pipe: 194
68.7
68.7

0.0
0.0

61.5
61.1

0.0
0.0

123
VK20

Pipe: 195
68.7
65.4

0.0
5.6

61.1
60.9

0.0
43.7

123
124

Pipe: 196
68.7
68.7

0.0
0.0

61.1
60.7

0.0
0.0

124
VK21

Pipe: 197
68.7
65.4

0.0
5.6

60.7
60.5

0.0
43.6

124
125

Pipe: 198
68.7
68.7

0.0
0.0

60.7
60.4

0.0
0.0

125
VK22

Pipe: 199
68.7
65.4

0.0
5.6

60.4
60.2

0.0
43.5

125
126

Pipe: 200
68.7
68.7

0.0
0.0

60.4
60.2

0.0
0.0

126
VK23

Pipe: 201
68.7
65.4

0.0
5.6

60.2
60.0

0.0
43.4

126
127

Pipe: 202
68.7
68.7

0.0
0.0

60.2
59.9

0.0
0.0

127
VK24

Pipe: 203
68.7
65.4

0.0
5.6

59.9
59.8

0.0
43.3

127
128

Pipe: 204
68.7
68.7

0.0
0.0

59.9
59.8

0.0
0.0

128
VK25

Pipe: 205
68.7
65.4

0.0
5.6

59.8
59.6

0.0
43.2

44.0
8.0

1.500
120
0.098

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

606.3
6.7

6.080
120
0.014

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.5
0.0
0.3

43.8
8.0

1.500
120
0.097

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

562.5
6.2

6.080
120
0.012

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.4
0.0
0.3

43.7
7.9

1.500
120
0.097

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

518.8
5.7

6.080
120
0.010

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.4
0.0
0.2

43.6
7.9

1.500
120
0.096

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

475.2
5.3

6.080
120
0.009

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.3
0.0
0.2

43.5
7.9

1.500
120
0.096

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

431.8
4.8

6.080
120
0.007

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.3
0.0
0.2

43.4
7.9

1.500
120
0.095

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

388.4
4.3

6.080
120
0.006

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.2
0.0
0.1

43.3
7.9

1.500
120
0.095

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

345.1
3.8

6.080
120
0.005

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.2
0.0
0.1

43.2
7.8

1.500
120
0.095

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 18
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
PIPE TAG
Q(GPM) DIA(IN) LENGTH
PRESS.
END
ELEV. NOZ.
PT
DISC. VEL(FPS) HW(C)
(FT)
SUM.
NODES
(FT)
(K)
(PSI) (GPM)
FL/FT
(PSI)

128
129

Pipe: 206
68.7
68.7

0.0
0.0

59.8
59.6

0.0
0.0

129
VK26

Pipe: 207
68.7
65.4

0.0
5.6

59.6
59.5

0.0
43.2

129
130

Pipe: 208
68.7
68.7

0.0
0.0

59.6
59.6

0.0
0.0

130
VK27

Pipe: 209
68.7
65.4

0.0
5.6

59.6
59.4

0.0
43.2

130
131

Pipe: 210
68.7
68.7

0.0
0.0

59.6
59.5

0.0
0.0

131
VK28

Pipe: 211
68.7
65.4

0.0
5.6

59.5
59.3

0.0
43.1

131
132

Pipe: 212
68.7
68.7

0.0
0.0

59.5
59.4

0.0
0.0

132
VK29

Pipe: 213
68.7
65.4

0.0
5.6

59.4
59.3

0.0
43.1

132
133

Pipe: 214
68.7
68.7

0.0
0.0

59.4
59.4

0.0
0.0

133
VK30

Pipe: 215
68.7
65.4

0.0
5.6

59.4
59.2

0.0
43.1

133
134

Pipe: 216
68.7
68.7

0.0
0.0

59.4
59.4

0.0
0.0

134
VK31

Pipe: 217
68.7
65.4

0.0
5.6

59.4
59.2

0.0
43.1

134
135

Pipe: 218
68.7
68.7

0.0
0.0

59.4
59.4

0.0
0.0

135
VK32

Pipe: 219
68.7
65.4

0.0
5.6

59.4
59.2

0.0
43.1

301.9
3.3

6.080
120
0.004

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.1
0.0
0.1

43.2
7.8

1.500
120
0.095

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

258.7
2.9

6.080
120
0.003

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.1
0.0
0.1

43.2
7.8

1.500
120
0.095

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

215.5
2.4

6.080
120
0.002

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.1
0.0
0.0

43.1
7.8

1.500
120
0.094

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

172.4
1.9

6.080
120
0.001

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

43.1
7.8

1.500
120
0.094

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

129.3
1.4

6.080
120
0.001

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

43.1
7.8

1.500
120
0.094

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

86.2
1.0

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

43.1
7.8

1.500
120
0.094

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

43.1
0.5

6.080
120
0.000

PL
3.85
FTG T
TL 34.29

PF
PE
PV

0.0
0.0
0.0

43.1
7.8

1.500
120
0.094

PL
3.28
FTG 3E
TL 16.79

PF
PE
PV

1.6
1.4
0.4

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 19
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
NOTES:
(1) Calculations were performed by the HASS computer program

(2) The system has been calculated to provide an average


imbalance at each node of 0.010 gpm and a maximum
imbalance at any node of 0.148 gpm.
(3) Velocity pressures are printed for information only, and are
not used in balancing the system. Maximum water velocity
is 19.9 ft/sec at pipe 150.

(4) PIPE FITTINGS TABLE


Pipe Table Name: CUSTOM.PIP
PAGE: *
Diameter
(in)
1.049
1.500
2.067
PAGE: E
Diameter
(in)
4.240
6.080
7.980
9.790
11.650

MATERIAL: S40
HWC: 120
Equivalent Fitting Lengths in Feet
E
T
L
C
B
G
A
Ell
Tee LngEll ChkVlv BfyVlv GatVlv AlmChk
2.00
5.00
2.00
5.00
6.00
1.00 10.00
4.50
9.01
3.00 10.51
9.01
1.50 15.01
5.00 10.00
3.00 11.00
6.00
1.00 10.00
MATERIAL: PVC150
HWC: 150
Equivalent Fitting Lengths in Feet
E
T
L
C
B
G
N
Ell
Tee LngEl ChkVl BfyVl GatVl NPTee
19.00 39.00 12.00 43.00 23.00
4.00 39.00
21.00 46.00 14.00 49.00 15.00
5.00 46.00
26.00 50.00 19.00 64.00 17.00
6.00 50.00
28.00 64.00 20.00 70.00 24.00
6.00 64.00
34.00 76.00 23.00 82.00 27.00
8.00 76.00

D
DPVlv
10.00
15.01
10.00

N
NPTee
5.00
9.01
10.00

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 20
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA

WATER SUPPLY ANALYSIS

Static: 140.00 psi Resid: 125.00 psi Flow: 2000.0 gpm

180.0

LEGEND
150.0

G
A
G
E
P
R
E
S
S
U
R
E
(
p
s
i
)

120.0

Available pressure
120.61 psi @ 2297.9 gpm

Required pressure
120.61 psi @ 2297.9 gpm

1
2

90.0

60.0

30.0

0.0

-14.7
80012001600 2000

2400
2800
3200
FLOW (GPM)

3600

4000

SPRINKLER SYSTEM HYDRAULIC ANALYSIS


Page 21
DATE: 6/12/2014C:\HASS\RESERVA FRIA ETEN_ENFRIAMIENTO LATERAL+HIDRANTE H3+ESPUMA (NORMAL)
JOB TITLE: PROTECCION TANQUE 48A ( 48B): ENFR. TECHO+HIDRANTE H3+ESPUMA
SPRINKLER SYSTEM DIAGRAM WITH FLOWPLOT
1516
<24>
<20> <22> 17
500.7
500.7 500.7
<23>
<21>
0.0
0.0
H8 DIL_TPRI

18

<26>
500.7

19

<25>
0.0
H9

<19>
500.7

14<18>
DIL_T
0.0
<27>
500.7

<17>
500.7

GEN_AUX
13<16>
H7
0.0
<29A>
<15>
0.0
12 500.7<30>
22
777.7

H4
<28A>
0.0
21 <28>20
777.7 <31>

<29>
777.7

23<32>
1278.4
24 <34>25
27
<36> 26 <38>
1278.4778.4 <35>
1019.5
1019.5
TAN_DIES 1797.9
<33>
<37>
50
500.0 <61>
0.0
<39>
H3
TALL_ALM
1019.5
1797.9
102
100
52 <62>
51
<153>
<150>
<63>
<151>
VK9
112
VK8
VK10
VK7
VK11
75
53
54
1389.0
1797.9
1797.9
VK6
<172>
28
VK12
<170>
<173>
<174>
101
VK5
<168>
<119>
<65>
<176>
<154>
VK13
<166>
<178>
VK4
<164>
VK14
<180>
0.0
VK3
<162>
<118>
409.0
<182>
VK15
111
<120>
<66>
110
B17
B18
74
113
VK2
<160>
109
RISER_TD
114
<184>
108
VK16
43.2
<116>
<117>
345.1
388.4
RISER_ES
301.9
115
761389.0
431.8
55258.7
<158>
0.0
0.0
VK1
107
103
475.2
<186>
215.5
116
VK17
518.8
<156>
106
172.4
117
<188>
562.5
0.0
<115>
105
129.3
VK18
0.0
118
<121>
<67>
<190>
606.3
86.2
B33
B34
77
B19
B20
73
104
B1
56
B20.0
0.0
0.0
650.3
119
VK19
RISER_LD
<192>
<122>
<123>
<113>
<114>
<68>
<69>
43.1
120
694.5
<40>
VK20 <194>
0.0
121
0.0
0.0
650.3
<124>
<70>
<112>
VK21
<196>
122
B40
B35
B36
78
B21
B22
72
B3
57
B
B8
4
606.3
0.0
0.0
0.0
0.0
0.0
0.0
0.0
<125>
<126>
<110>
<111>
<71>
<72>
VK22
<198>
123
562.5
0.0
0.0
0.0
VK23
124
<200>
518.8
<127>
<73>
<133>
<109>
<79>
H10
B39
B37
B38
79
B23
B24
71
B5
58
B
B
6
7
0.0
0.0
0.0
0.0
0.0
0.0
VK24
125
<202>
475.2
<128>
<129>
<107>
<108>
<74>
<75>
<87>
126
VK25
<132>
<130>
<76>
<78>
<204>
431.8
81
80
59
60
0.0
0.0
0.0
0.0
0.0
<131>
<77>
<106>
127
VK26
<206>
388.4
<134>
<136>
<82>
<80>
B41
B43
B44
82
B25
B26
70
B11
B12
61
B9
0.0
0.0
0.0
0.0
0.0
0.0
0.0
<137>
<138>
<104>
<105>
<83>
<84>
VK270.0
128
0.0
0.0
0.0
0.0
<208>
345.1
0.0
0.0
VK28
129
<210>
301.9
<135>
<139>
<85>
<81>
<103>
0.0
0.0
0.0
0.0
B42
B45
B46
83
B27
B28
69
B13
B14
62
B10
VK29
0.0
0.0
0.0
0.0
0.0
0.0
<212>
130
258.7
<140>
<141>
<101>
<102>
<86>
VK30
<214>
131
215.5
0.0
0.0
0.0
0.0
0.0
VK31
<142>
<88>
<100>
<216>
132
172.4
VK32
B47
B48
84
B29
B30
68
B15
B16
63
0.0
0.0
0.0
0.0
0.0
<218>
133
<143>
<144>
<98>
<99>
<89>
<90>
129.3
134
0.0
0.0
0.0
86.2
<145>
<91>
<97>
85
64
<41>
135
43.1
B31
B32
67
0.0
0.0
0.0
0.0
0.0
0.0
<95>
<96>
0.0
0.0
<146>
<92>
0.0
1019.5
<94>
86
66
65
<147>
<93>
0.0
0.0
0.0
0.0
0.0
0.0
0.0

<14>
1278.4

B_ELECTR<1>
23
H5
<3>
1
2297.9
2297.9
11<13>
H6
<4>
<51>
0.0
<12>
2297.9 0.0
10 1278.4
9
35
84 <52>
34
<11> <10>
<53>
<5>
<50>
1278.4 1278.4
1278.4
1019.5
1019.5
1019.5

H1

H2
<49>
0.0

33

OFICINAS H11
<47>
0.0

<48>
1019.5

32

<46>
1019.5

<45>
<43>
0.00.0
31<44>
30 <42>
29
1019.5
1019.5

Vous aimerez peut-être aussi