Vous êtes sur la page 1sur 1

Alluminium Glasses

1 + 2 No13mm dia bars

MH1

1800
2250
2500

675
675
675

900
900
900

1112.5
1417.5
1561.5

12.2m
14.4m

2800

675

900

1800.0

18.3m

25

3300

675

900

2083.5

30.5m

30

2500

900

1050

2358.0

36.6m

35

2550

900

1050

2502.0

42.6m

40

3000

900

1050

2847.5

48.7m

45

3300

900

1050

3240.0

54.8m

50

3600

900

900

3685.5

60.0m

60

3150

1200 1200

4419.0

66.0m

70
80

3750
4250

1200 1200
1200 1200

5265.0
6895.0

73.0m
79.2m

90

4720

1200 1200

6525.0

85.2m

100

5300

1200 1200

7416.0

91.0m

125

4200

1350 1500

8842.5

97.0m

150

5000

1350 1500

10422.0

103.6m

175

5700

1350 1500

11974.5

109.5m

200

6530

1200 1500

13581.0

115.8m

225

6400

1200 1650

14940.0

121.9m

250

7000

1200 1650

1633.5

128.0m

275

7000

1200 1800

1785.5

134.0m

300

7600

1200 1800

1895.0

140.0m

600 x 450 mm cast iron


cover

4No 10mm dia bars at 150 c/c


double seal cast iron
man hole covers

No. OF
USERS
10
15
20

1 + 2 No13mm dia bars

MH2

MH3

4No 9mm dia


600x600 450x450 bars at 150 c/c

MH4

450x450 600x600

Benching rendered 12mm


thick, finished smooth with
steel float

100mm dia. half


round channel.

4No 10mm dia bars

125 th. conc. foundation


(mix 1:3:6).

PLAN OVER COVERS scale 1:75


600 x 450mm cast iron covers
complete with frames

SECTION C - C (Scale 1:25)


Selected filling in six layers well
rammed and consolidated into place.

Second hand G.C.I sheet or


roofing felt

100mm thick R.C cover slab.

PLAN AT TOP (Scale 1:50)

100mm dia agricultural


pipes laid with open joints,
minimum fall 1:10.

A
Half round channel

100mm dia cast iron inlet / outlet pipes

SELECTED STONE 150 DOWN TO 20mm

ELEVATION 3 SCALE 1:100

L
IN

ELEVATION 4 SCALE 1:100

LONGITUDINAL SECTION THRU


PERCOLATION TRENCH

OUT

TO SOAK PIT $
PERCOLATION
TRENCHES

600 x 450 mm cast iron


cover

A
PLAN (Scale 1:50)

Benching rendered 12mm


thick, finished smooth with
steel float

GROUND LEVEL

100mm dia. inlet /


outlet cast iron pipe

D
B

Concrete to foundation (mix 1:3:6) to


be at thickness specified

SECTION A - A (Scale 1:50)

SECTION C - C (Scale 1:25)


Invert level
Selected stone

125 th. conc. foundation


(mix 1:3:6).

CROSS SECTION THRU DRAIN PIPE TRENCH

100mm th. reinforced concrete


cover slab (mix. 1:2:4)

600 x 450 mm
cast iron cover

CAPACITY PERCOLATION
IN LITRES .TRENCHES

7.5m

600 x 450 mm cast iron


cover

75 300 min

GROUND LEVEL

100mm dia half round channel

125mm thick concrete base (mix. 1:3:6).


Depth to invert level not more than 5,580
1500mm

Inlet pipe

450

Concrete to foundation (mix 1:3:6)


to be at thickness specified

Selected stone profile.

gl. support bracket built into


230mm thick block wall

25mm th. cement screed


finished smooth with steel float.

ELEVATION 2 SCALE 1:100

SECTION THRU SOAK PIT


NO. DATE.

D3

2,400

300 225

Building your dream

fry proof cover

230

GROUND PLAN, ELEVATION,


SCHEDULES, AND POSSIBLE DETAILS

SECTION M-M MAJOR

COL.

4Y12-01-150

SECTION THROUGH THE LATRINE


SCALE 1:65

690

690X690X230

WINDOW AND DOOR SCHEDULE


NO.

D1 03

534

8,792

20,487

1
GROUND PLAN SCALE 1:100

230

5,872

5,642

W2 05

15

15

SUBSTRUCTURE CONSTRUCTION
25mm thick cement sand screed mix 1:4 on
100mm thick plain insitu concrete slab mix 1:3:6 on
200mm thick well compacted hardcore filling on
Well compacted marram filling
Well burnt Clay Brick plinth wall on
690X230mm thick plain insitu foundation concrete
depth of foundation to be determined on site.

DIOCESE OF KASESE
P.O BOX 75
KASESE

W3

03

300

650

Casement Arched
Window With
Permanent
Vents On Double
Side Hung

Casement Window
Louvres With
Permanent
Vents On Top
Hung

DESCRIPTION
Casement Arched
Door With
Permanent
Vents Over On
Double Side Hung

Signature
_________________

Descrip o n:

Paper Size :

WORKING DRAWINGS
Date:

A1 Landscape

MAY, 2016
Scale:

1,500

D2 01

900

Flush Door With An


Arch & Permanent
Vents Over
On Single Side Hung

Sheet No.

Designed by: M.S


TELL.0702-889145/0782-889145
Drawn by: J T
TELL.0705-808785/0788-873848

As shown on drawings
400

900

1,000

2,190

600

1,500

1,500

1,441

900

900

500

230
1,327

1,200

SIZES
300

W1 15

Casement Arched
Window With
Permanent
Vents On Double
Side Hung

MK

2,100

900

DESCRIPTION

2,100

SIZES

2,400

NO.

2,400

MK

COLUMN BASE

Client :

DATE : -------/05/2016

230

500

7,000

900

W1

PROPOSED KATIRI CATHOLIC CHURCH

150mm thick mass concrete

4Y12-02

1,000

D1
W1

20,000

4Y12-01-150

Project Name and Address :

Lined pit

1,500

3,000

8,739

230

300 230
633 300
1,200
1,240
600

8,215

8,445
W

W1

229

8,691

40
0

0
40

230 230 230

11 538

NA
VE

W1

W1

NA
VE

11 538

703

D1

D1

9,242

ARCHITECT:

100mm thick reinforced


concrete slab

1,600

690

22

703 22

internal walls finishes with


cement lime plaster

2,800

2,100

100
4Y12-02

Plot 22 Alexander street Kasese

100x50mm rafter

Drawings Title :

2,900

9,048

9,048

NA
VE

NA
VE

29,353

1
W

8,307

W1

20,000

5,809

RACO CONSTRUCTION LTD


Engineers & Architects
Constructors & Designers

690

5,809

DATE.

ALTER
1

W1

3,151

8,307

12R8-03-200

2,730
230
3,660

854
900

9,242

Roof pitch; 30 deg.


Prepainted G 28 on
A steel trus (see engineer's details)
Fixed to wall with iron hoops
placed at 2000mm c/c or less.

792

887

230

1,593

XR8-03-200

319
1,200
891

D3

SACRIST

wire netting cover to 100mm dia. pvc


pipe
28 gauge corr. gal. iron sheets

ROOF SPECIFICATIONS

900

230

W1

3,562

W2

3,000

D2

230

SITTING
ROOM

230

230

3,000

4,311

100x75mm wall
plates

4Y12-02

900

230
230

1,000
0
230 230

123
636
471
623
1,200

D2
D2

W2

ROOM

8,739

1,316

1,200

4,230

859
1,200
2,813

4,198

230

2,881

ISSUED TO NO.

75x50mm purlins

230

1,502

1,500

844
230

230
7,389

230

230

D2

BED
ROOM

29,353

1,200

D2

D3

WC
230

230

W3

500

1,338

5,427

W3

D2

230WOMEN 230MEN
1,200
1,200

WC

230

123 636 471

W2

D2

1,627

W2

230 1,000 230

359 636 140

2
D

1,200

230

2,581

W3

981

1,135

500

2
D

2,326

926

5,427

W2

359 636 140

5,841

1,230

4,741

230

21

230

1,863

2,730

230 905

DESCRIPTION.

ISSUES

20,487
5,841

CEILING
(A) Painted Cement / Sand plaste or
(B) Powder coated aluminium suspended ceiling ( Hunter doorglass) or
(C) Armstrong ceiling

NO. DATE.

SECTION L - L (Scale 1:50)

3
21

WALLS
(A) Internally plastered, steel float finished, painted with atleast two coats, or
(B) Wallpaper or
(C) 6mm Ceramic Tiles or
(D) 12mm thick Granite or
(E) Glass block wall

REVISIONS

Selected filling well compacted and consolidated.

230

ELEVATION 1 SCALE 1:100

OUT

50 min

IN

Optional design considerations to be adapted based on client's preferences:

FLOOR
(A) 150mm Cement/ Sand Plaster or
(B) 25mm, 150mm high Hardwood or
(C) 9mm, 150mm high Ceramic Tiles or
(D) 150mm high Granite

Benching

WORKING LEVEL

GENERAL NOTES
1. Contractor to verify dimension on site before commencement of works
and report any discrepancies to consulting Architect. It should be
acknowledged that written dimensions(in millimeters or meters) be
followed in preference to scaled dimensions.
2. Architectural drawings to be read with relevant structural, mechanical and
electrical drawings, bills of Quantities and Technical Specifications. Any
discrepancy should be reported immediately to the Architect. It should be
noted that all reinforced concrete work is to be in accordance with the
structural
engineer's specifications and details.
3. All walls less than 200mm thick to be reinforced with hoop iron at every
two alternate course.
4. All retaining walls to be damp proofed civil engineer's specification and
detailing.
5. All sanitary work to be in accordance with M.O.H rules and regulations:
-Drainange pipes under drive ways to have 150mm concrete surrounding.
-All waste pipes and soil pipes are to be in ducts and the bends to have all
cleaning eyes accessible from outside.
-All manholes within building area, driveway and parking to have heavy duty
air tight covers and double sealed.
6. All windows and external glazed doors on ground floor to have burglar
proofing to detail, where applicable.
7. All door frames to be rebated and molded and be & be full width of wall
with
molded architrave to detail and provide rubber door stops to all doors.
8. Stair case and lobby doors to be self closing and 1/2 hour fire
resistant. Fire fighting equipment to be provided and installed by Building
Fire
Consultants where deemed necessary, as required by law.
9. Provide G.I 125x100 rain water down pipes and 125x100 G.I box gutter
with brackets etc, where applicable and necessary.
10.Lay 1 layer and paving slabs 600x600 on sand along the perimeter of the
building.
11.Samples of fittings, materials etc, to be produced and approved before
commencing work.
12.Windows to have P.C cills built in P.V pelment boxes & timber internal
window cills & skirting.
13.Wood trusses ,frames & purlins to be painted with two coats of antitermite
oil paint. While, where Steel trusses / portal frames & purlins have been
used,
apply two coats of oil paint.
14.The ARCHITECT shall not accept any LIABILITY for the works which he
has
not been expressly instructed in WRITING (& has accepted to proceed in
writing) to SUPERVISE or for any ommissions or deviations from his
Drawings/Technical Specifications. Nor Shall he take responsibility for works
handled by other nominated Consultants / Contractors.

Vous aimerez peut-être aussi