Vous êtes sur la page 1sur 12

Eco King

R410A & R407C Series

Zero

Ozone

Depletion

Potential

R410A
R407C

Product Line Up

Refrigerant Alternatives
> Alternatives Refrigerants To Save Ozone:
1) R410A

2) R407C

R410A
50%
R-32

0.055
ODP

23%
R-32

25%

R-125

52%

R-134a

0 OD

R22

0 OD

R40

7C

R410

The Comparison of
Ozone Depletion Potential (ODP)

50%

R-125

R407C

* The lower the ODP value the better


the environmental performance

The Composed of System R410A & R407C


* R-32: CH2F2 ; R-125: C2HF5 ; R-134a: CF3CH2F

R410A : The Ozone - Friendly Refrigerant


Benefits of R410A against other type
of refrigerant:

UV-B

UV-B

Higher efficiency of capacity.


Lower power consumption.
Zero ozone depletion potential
- save our ozone.

R410A
REFRIGERANT

Classic Refrigerants Deplete Ozone

Sunlight Breakdown

2 HCFCs In The Atmosphere

R-22 Air-Conditioner
1 Spew Out HCFCs

Breakdown Products

3 Destroy Ozone

ec
ot
r
P

HCFC - Hydrochloroflarocarbon (R-22)


- Chlorine Breakdown From R-22 (CHCF2)
- Ozone (O3)
C
+
CO +

O3
O3

CO + O2
C + 2 O2

tiv

zo
eO

er
ne Lay

UV-B Radiation Cannot Be Filtered By


The Depleted Ozone Layer And Causes:
Sunburn
Skin Cancer
DNA Damage
Reduce Vitamin A In Skin
Cataracts, Pterygium, Pinguecula
Formation At Eyes.

* C (Chlorine) deplete the protective ozone


layer by these processes.

Regulations
* According to Montreal Protocol, R22 will be phased-out by year 2030.
* In Malaysia, Department of Environment (DOE) has implemented HCFC Phase Out Management Plan (HPMP).
Montreal Protocol

Freeze at base line

10%

35%

67.5%

Allow 2.5% per


annum for service
2015:
1. Prohibit production, assembly
& import HCFC < 2.5 hp air
conditioner.
2. Inclusion of HCFCs in the list of
restricted gases.

2009 2010

2013

2015

2020:
Prohibit production,
assembly & import of all
HCFC equipment.

2020

2040:

2025:
No new installation of
equipment using HCFC.

2025

2030

Total prohibit on import


& use of HCFC.

2040

Indoor Model

Outdoor Model

Y5WM10/15/20/25L
Y5WM10/15/20/25M
Y5WM311

Capacity
Range

1.0 - 2.5 hp
Y5SL 10/15C3

R410A

Y5CK10/15C
Y5CK20/25/30/40/50A2

1.0 - 5.0 hp
Y5SL 20C3

Y5CE15/20/25/30E
Y5CE40/50D
Y5CE62C

1.5 - 6.0 hp
Y5SL 25/28C3

TYPE OF REFRIGERANT

Y5CC10C
Y5CC15/20/25C
Y5CC30/40CL
Y5CC50/60C

1.0 - 6.0 hp
Y5SL 35-61D

YSB80/100B
YSB125B/150B1
YSB200B2
YSB250/300B2
YSB350B3
YSB400B4

R407C

Eco King (Non Inverter Series)

R410A & R407C Product Line Up

8.0 - 75.0 hp

M4YSS 75-150D

6.0 - 42.0 hp
Y4RT60/80/100/120/150/200A

YWM10/15/20/25LW
YWM301W
YCK10/15CW
YCK20/25/30/40/50AW
YCE15EW
YCE20/25/30/40/50DW
YCC10/15/20/25/30/
40/50/60CW
YSB75/100/125/150BW

Y4RT250/300/360/420A

Y4AC 25/30C

2.5 - 15.0 hp

Y4AC 80/100/120/150C

Y4AC 40/50/60C

Wall Mounted Series


Y5WM-L Series

Y5WM-M Series

Y5WM-L Series : The beautiful and clean design brings out a feeling of elegance and
simplicity in your interior decoration.
Y5WM-M Series : Designed with a modern-stylish and glossy exterior casing to enhance
your interior decoration.

Ion-Plasma * Only for Y5WM-M Series


Purify The Air
>
effectively deactivated the bacteria by damaging microbial DNA and surface
structures without being harmful to human tissues.
Cleanse The Air
> Extra negative ions produced by
can remove airborne contaminates from the
air we breathe and bring the air fabulously fresh and clean.

Quiet Operation
Users are given more choices of up to five
selectable fan speeds. By selecting the quiet
mode users can enjoy the refreshing cool air
at the sound level as low as 25dBA.

60
50

Type Of Area

* Sound pressure levels are measured according to


JIS C 9612 standard.

70

Sound Pressure Level

Wall Mounted Series Features

> Outlook Design

40
30

25
20

10

Noisy Restaurant
Library
Hospital Private Room
Just Audible

Compact And Easy To Use Controller


>
>
>
>
>

Prominent temperature display.


Real time clock display.
Easily accessible buttons.
Dedicated buttons for Quiet and Turbo function.
Come with wireless or wired controller.
GS01

SLM8

Built Starter (BIS)


> Protect air conditioner from overcurrent condition.
> This will prolong the units lifespan as the unit will be protected.

High Efficiency Hydrophilic Fin


> It encourages condensation of water.
> The condensated water moves easily to the drain pan thus enhancing the cleanliness and lifespan of
the cooling coil.

Long Air Throw

6M

> New powerful motor combines with advanced control technology to


push air further to provide a longer air throw.
> During operation, the air throw can reach up to 6m.

Air Throw reach up to 6M


based on CFD simulation results

Turbo Mode
> This function is available in COOL mode.
> Upon activation, the unit will run to full power with the indoor fan running at high speed for 20 minutes.
This will provide a fast cooling during operation.

Smooth Air Distribution


> SCR motor (Silicon Control Rectifier), voltage
controlled speed provides better and smooth
air flow swing.
> High efficiency X-flow fan provides smooth air flow and quiet operation.

Auto Random Restart


> Once power resumes after a blackout, the unit
will restart automatically at its last setting condition.

Power Failure

Power Resume

Setting stored before


power failure

Specifications

Wall Mounted

Y5WM10/15/20/25L

Y5WM10/15/20/25M

Y5WM311

R410A
MODEL

INDOOR UNIT

Y5WM10L
Y5WM10M

Y5WM15L
Y5WM15M

Y5WM20L
Y5WM20M

Y5WM25L
Y5WM25M

Y5WM311

OUTDOOR UNIT

Y5SL10C3

Y5SL15C3

Y5SL20C3

Y5SL25C3

Y5SL28C3

Btu/h

9,500

12,000

18,000

22,000

26,000

2,784

3,517

5,275

6,448

7,620

825

1,280

1,635

1,870

2,560

TOTAL COOLING CAPACITY


INPUT POWER
RUNNING CURRENT, 1 [3]
EER
POWER SOURCE

3.70

5.81

7.19

8.26

12.20

Btu/h/W/W/W

11.52 / 3.37

9.38 / 2.75

11.01 / 3.23

11.76 / 3.45

10.16 / 2.98

220-240 / 1 / 50

V/Ph/Hz

REFRIGERANT TYPE/CONTROL
AIR FLOW

CFM

SOUND PRESSURE
LEVEL

HIGH
LOW
SUPER LOW
INDOOR
UNIT

UNIT DIMENSION
(HxWxD)

dBA

288 x 800 x 206


mm

INDOOR UNIT
OUTDOOR UNIT

COPPER PIPE SIZE

R-410A / OUTDOOR CAP. TUBE


531
42
36
35
310 x 1,065 x 224

288 x 800 x 216

OUTDOOR UNIT

UNIT WEIGHT

355
40
29
28

342
38
27
25

L-SERIES
M-SERIES

29

LIQUID

mm/in

GAS

mm/in

670
49
45
360 x 1,200 x 200

310 x 1,065 x 233


654 x 855 x 328

540 x 700 x 250


9

kg

614
46
40
37

756 x 855 x 328


17

14
30

47

50

57

6.4 / 1/4
9.5 / 3/8

9.5 / 3/8

12.7 / 1/2

15.9 / 5/8

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
COOLING - 27C DB / 19C WB INDOOR AND 35C DB / 24C WB OUTDOOR
4) SOUND PRESSURE LEVELS ARE MEASURED IN SOUND ROOM.

Ceiling Cassette
R410A
INDOOR UNIT
OUTDOOR UNIT

MODEL
TOTAL COOLING CAPACITY

INPUT POWER
RUNNING CURRENT, 1 [3]
EER
POWER SOURCE
REFRIGERANT TYPE/CONTROL
AIR FLOW
HIGH
SOUND PRESSURE LEVEL
LOW
UNIT DIMENSION (WITH PANEL) INDOOR UNIT
(HxWxD)
OUTDOOR UNIT
INDOOR UNIT
UNIT WEIGHT
OUTDOOR UNIT
LIQUID
COPPER PIPE SIZE
GAS

CFM
dBA
mm
kg
mm/in
mm/in

INDOOR UNIT
OUTDOOR UNIT

MODEL
TOTAL COOLING CAPACITY

INPUT POWER
RUNNING CURRENT, 1 [3]
EER
POWER SOURCE
REFRIGERANT TYPE/CONTROL
AIR FLOW
HIGH
SOUND PRESSURE LEVEL
SUPER LOW
UNIT DIMENSION (WITH PANEL) INDOOR UNIT
(HxWxD)
OUTDOOR UNIT
INDOOR UNIT
UNIT WEIGHT
OUTDOOR UNIT
LIQUID
COPPER PIPE SIZE
GAS

Btu/h
W
W
A
Btu/h/W / W/W
V/Ph/Hz

Btu/h
W
W
A
Btu/h/W / W/W
V/Ph/Hz
CFM
dBA
mm
kg
mm/in
mm/in

Y5CK10C
Y5CK15C
Y5SL10C3
Y5SL15C3
9,500
12,500
2,784
3,664
900
1,300
4.0
5.9
10.56 / 3.09
9.62 / 2.82
220-240 / 1 / 50
R-410A / OUTDOOR CAP. TUBE
410
41
41
35
34
250 x 570 x 570 (295 x 640 x 640)
540 x 700 x 250
16 + 2
28
30
6.4 / 1/4
9.5 / 3/8
12.7 / 1/2
Y5CK20A2
Y5SL20C3
18,500
5,422
1,740
7.68
10.63 / 3.12

Y5CK10/15C

Y5CK20/25/30/40/50A2

Y5CK25A2
Y5CK30A2
Y5CK50A2
Y5CK40A2
Y5SL25C3
Y5SL28C3
Y5SL35D
Y5SL40D
Y5SL50D
22,200
28,000
30,500
40,000
45,000
6,506
8,206
8,939
11,723
13,189
1,950
2,750
2,820
3,850
4,390
8.65
12.90
13.70
[6.90]
[7.80]
10.18 / 2.98
11.38 / 3.34
10.82 / 3.17
10.39 / 3.04
10.25 / 3.00
220-240 / 1 / 50
380-415 / 3 / 50
R-410A / OUTDOOR CAP. TUBE
1,200
600
680
860
1,030
47
34
37
41
44
39
35
27
30
32
265 x 820 x 820 (345 x 930 x 930)
300 x 820 x 820 (385 x 930 x 930)
852 x 1,030 x 400
756 x 855 x 328
654 x 855 x 328
39 + 4
26 + 4
28 + 4
31 + 4
41 + 4
47
50
57
86
95
98
6.4 / 1/4
9.5 / 3/8
15.9 / 5/8
12.7 / 1/2

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
COOLING - 27C DB / 19C WB INDOOR AND 35C DB / 24C WB OUTDOOR
4) SOUND PRESSURES LEVEL ARE MEASURED IN SOUND ROOM.

Ceiling Exposed

R410A

Y5CE15/20/25/30E
INDOOR UNIT
OUTDOOR UNIT

MODEL
TOTAL COOLING CAPACITY

INPUT POWER
RUNNING CURRENT, 1 [3]
EER
POWER SOURCE
REFRIGERANT TYPE/CONTROL
AIR FLOW
HIGH
SOUND PRESSURE
LEVEL
LOW
INDOOR UNIT
UNIT DIMENSION
(HxWxD)
OUTDOOR UNIT
INDOOR UNIT
UNIT WEIGHT
OUTDOOR UNIT
LIQUID
COPPER PIPE SIZE
GAS

Btu/h
W
W
A
Btu/h/W / W/W
V/Ph/Hz
CFM
dBA
mm
kg
mm/in
mm/in

INDOOR UNIT
OUTDOOR UNIT

MODEL

Btu/h
W
W
A
Btu/h/W / W/W
V/Ph/Hz

TOTAL COOLING CAPACITY


INPUT POWER
RUNNING CURRENT, 1 [3]
EER
POWER SOURCE
REFRIGERANT TYPE/CONTROL
AIR FLOW
SOUND PRESSURE LEVEL

INDOOR UNIT
OUTDOOR UNIT
INDOOR UNIT
OUTDOOR UNIT
LIQUID
GAS

UNIT DIMENSION
(HxWxD)
UNIT WEIGHT
COPPER PIPE SIZE

Y5CE20E
Y5CE30E
Y5CE25E
Y5SL28C3
Y5SL20C3
Y5SL25C3
17,500
20,000
27,000
7,913
5,129
5,862
1,723
1,973
2,754
8.8
12.6
7.6
10.16 / 2.98
10.14 / 2.97
9.80 / 2.87
220-240 / 1 / 50
R-410A / OUTDOOR CAP. TUBE
520
580
640
508
48
56
48
50
43
44
41
46
218 x 1,080 x 630
654 x 855 x 328
756 x 855 x 328
540 x 700 x 250
28
26
27
57
30
47
50
9.5 / 3/8
6.4 / 1/4
12.7 / 1/2
15.9 / 5/8
Y5CE15E
Y5SL15C3
12,900
3,781
1,280
5.80
10.08 / 2.95

Y5CE40D
Y5SL35D
33,000
9,672
3,148
15.7
10.48 / 3.07
220-240 / 1 / 50

CFM
HIGH
LOW

Y5CE62C

Y5CE40/50D

dBA
mm
kg

86

mm/in
mm/in

Y5CE50D
Y5SL50D
43,000
12,603
4,700
[8.3]
9.15 / 2.68
380-415 / 3 / 50
R-410A / OUTDOOR CAP. TUBE
1,010
1,040
54
54
52
52
249 x 1,714 x 670
852 x 1,030 x 400
70
95
98
9.5 / 3/8
15.9 / 5/8
Y5SL40D
38,500
11,284
3,900
[8.5]
9.87 / 2.89

Y5CE62C
Y5SL61D
55,000
16,120
6,414
[9.6]
8.57 / 2.51

1,550
56
46
285 x 1,903 x 680
85
105
19.1 / 3/4

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
COOLING - 27C DB / 19C WB INDOOR AND 35C DB / 24C WB OUTDOOR
4) SOUND PRESSURE LEVELS ARE MEASURED IN SOUND ROOM.

Ceiling Concealed

R410A

Y5CC10C

MODEL

Y5CC15/20/25C

INDOOR UNIT
OUTDOOR UNIT

TOTAL COOLING CAPACITY


INPUT POWER
RUNNING CURRENT, 1 [3]
EER
POWER SOURCE
REFRIGERANT TYPE/CONTROL
EXTERNAL STATIC PRESSURE
AIR FLOW
HIGH
SOUND PRESSURE
LEVEL
LOW
INDOOR UNIT
UNIT DIMENSION
(HxWxD)
OUTDOOR UNIT
INDOOR UNIT
UNIT WEIGHT
OUTDOOR UNIT
LIQUID
COPPER PIPE SIZE
GAS

Btu/h
W
W
A
Btu/h/W / W/W
V/Ph/Hz
in.wg
CFM
dBA
mm
kg
mm/in
mm/in

Y5CC30/40CL
Y5CC50/60C

Y5CC15C
Y5CC20C
Y5CC25C
Y5SL15C3
Y5SL20C3
Y5SL25C3
12,500
18,000
21,000
3,664
5,275
6,155
1,297
1,757
2,003
5.7
7.6
8.9
9.64 / 2.82
10.24 / 3.00
10.48 / 3.07
220-240 / 1 / 50
R-410A / OUTDOOR CAP. TUBE
0.12
250
410
570
690
33
37
38
40
26
29
34
36
261 x 765 x 411
261 x 905 x 411
261 x 1,065 x 411
261 x 1,200 x 411
550 x 658 x 273
756 x 855 x 328
17
21
22
25
28
30
47
50
6.4 / 1/4
9.5 / 3/8
12.7 / 1/2
15.9 / 5/8
Y5CC10C
Y5SL10C3
9,500
2,784
961
4.0
9.89 / 2.90

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
COOLING - 27C DB / 19C WB INDOOR AND 35C DB / 24C WB OUTDOOR
4) SOUND PRESSURE LEVELS ARE MEASURED IN SOUND ROOM.

Specifications

Ceiling Concealed (Contd)


R410A - Contd
INDOOR UNIT

MODEL

Y5CC30CL
Y5SL28C3

Y5SL35D

Btu/h

26,000

7,620

W
A
Btu/h/W / W/W

OUTDOOR UNIT

TOTAL COOLING CAPACITY


INPUT POWER
RUNNING CURRENT, 1 [3]
EER
POWER SOURCE

Y5SL40D

Y5CC50C
Y5SL50D

32,000

39,000

45,000

55,000

9,379

11,430

13,189

16,120

2,892

3,287

12.8
8.99 / 2.63

15.2
9.74 / 2.85

4,287
[7.3]

4,600
[8.9]

5,360
[9.7]

9.78 / 2.87

10.26 / 3.01

in.wg
CFM

UNIT DIMENSION
(HxWxD)

INDOOR UNIT

UNIT WEIGHT
COPPER PIPE SIZE

LIQUID

mm/in

GAS

mm/in

305 x 1,302 x 638

38

41

57

86

0.59
1,430
53
51

0.59
1,720
52
46

378 x 1,299 x 541


852 x 1,030 x 400

756 x 855 x 328

kg

OUTDOOR UNIT

R-410A / OUTDOOR CAP. TUBE


0.47
1,280
49
45

285 x 1,007 x 600

mm

Y5CC60C
Y5SL61D

380-415 / 3 / 50

0.39
850
41
34

dBA

INDOOR UNIT
OUTDOOR UNIT

9.10 / 2.67

220-240 / 1 / 50

V/Ph/Hz

REFRIGERANT TYPE/CONTROL
EXTERNAL STATIC PRESSURE
AIR FLOW
HIGH
SOUND PRESSURE LEVEL
LOW

Y5CC40CL

95

378 x 1,499 x 541

54

62

98

105

9.5 / 3/8
15.9 / 5/8

19.1 / 3/4

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.
3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
COOLING - 27C DB / 19C WB INDOOR AND 35C DB / 24C WB OUTDOOR.
4) SOUND PRESSURE LEVELS ARE MEASURED IN SOUND ROOM.

High Static Ducted


YSB250/300B2

YSB200B2
YSB125B/150B1
YSB80/100B
YSB350B3

R407C
MODEL

INDOOR UNIT
OUTDOOR UNIT

TOTAL COOLING CAPACITY


INPUT POWER
RUNNING CURRENT, 1 [3]
EER
POWER SOURCE
REFRIGERANT TYPE/CONTROL
EXTERNAL STATIC PRESSURE
AIR FLOW
SOUND PRESSURE LEVEL
INDOOR UNIT
UNIT DIMENSION
(HxWxD)
OUTDOOR UNIT
INDOOR UNIT
UNIT WEIGHT
OUTDOOR UNIT
LIQUID
COPPER PIPE SIZE
GAS

MODEL

INPUT POWER
RUNNING CURRENT, 1 [3]
EER
POWER SOURCE
REFRIGERANT TYPE/CONTROL
EXTERNAL STATIC PRESSURE
AIR FLOW
SOUND PRESSURE LEVEL
INDOOR UNIT
UNIT DIMENSION
(HxWxD)
OUTDOOR UNIT

COPPER PIPE SIZE

mm
kg
mm/in
mm/in

INDOOR UNIT
OUTDOOR UNIT

TOTAL COOLING CAPACITY

UNIT WEIGHT

Btu/h
W
W
A
Btu/h/W / W/W
V/Ph/Hz
TYPE
in.wg
CFM
dBA

INDOOR UNIT
OUTDOOR UNIT
LIQUID
GAS

Btu/h
W
W
A
Btu/h/W / W/W
V/Ph/Hz
TYPE
in.wg
CFM
dBA
mm
kg
mm/in
mm/in

YSB80B
M4YSS75D
73,000
21,395
8,172
[15.1]
8.93 / 2.62

YSB100B
M4YSS100D
91,000
26,671
10,950
[19.8]
8.31 / 2.44

0.4
2,500
56

0.4
3,200
57
572 x 1,502 x 761
1,041 x 981 x 981

92
170
12.7 / 1/2
25.4 / 1

102
184
15.9 / 5/8
28.6 / 1-1/8

YSB400B4

YSB125B
YSB150B1
M4YSS125D
M4YSS150D
108,000
145,000
31,653
42,497
12,100
15,599
[21.6]
[28.5]
8.93 / 2.62
9.30 / 2.72
380-415/3/50
R-407C / Indoor TXV
0.6
0.6
4,200
4,600
58
59
885 x 1,640 x 1,040
1,142 x 1,083 x 1,083
176
189
197
268
15.9 / 5/8
15.9 / 5/8
34.9 / 1-3/8
34.9 / 1-3/8

YSB250B2
M4YSS125D x 2
216,000
63,306
24,730
[43.7]
8.73 / 2.56

YSB300B2
YSB350B3
YSB400B4
M4YSS100D + M4YSS125Dx2
M4YSS100D x 4
M4YSS150D x 2
290,000
307,000
364,000
84,994
89,977
106,682
32,998
35,020
41,435
[57.3]
[62.9]
[77.1]
8.79 / 2.58
8.77 / 2.57
8.78 / 2.57
380-415 / 3 / 50
R-407C / Indoor TXV
1.16
1.12
1.12
1.24
8,000
9,000
10,500
12,000
63
66
66
66
1,291 x 1,866 x 1,199
1,546 x 2,122 x 1,199 1,546 x 2,274 x 1,466
(1,041 x 981 x 981) +
(1,041 x 981 x 981) x 4
(1,142 x 1,083 x 1,083) x 2
(1,142 x 1,083 x 1,083) x 2
343
440
513
197 x 2
268 x 2
184 + (197 x 2)
184 x 4
15.9 / 5/8
15.9 / 5/8
15.9 / 5/8
15.9 / 5/8
28.6 / 1-1/8 + 34.9 / 1-3/8
28.6 / 1-1/8
34.9 / 1-3/8
34.9 / 1-3/8

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 13253.
3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
COOLING - 27C DB / 19C WB INDOOR AND 35C DB / 24C WB OUTDOOR.
4) SOUND PRESSURE LEVELS ARE MEASURED IN SOUND ROOM.

YSB200B2
M4YSS100D x 2
182,000
53,341
21,030
[39.2]
8.65 / 2.54

1.06
6,400
61
945 x 1,894 x 980
(1,041 x 981 x 981) x 2
220
184 x 2
15.9 / 5/8
28.6 / 1-1/8

High Static Ducted (Contd)


R407C - Contd
MODEL

INDOOR UNIT

YSB500B4
M4YSS125D x 4
M4YSS100Dx2 + M4YSS125Dx2

OUTDOOR UNIT

TOTAL COOLING CAPACITY


INPUT POWER
RUNNING CURRENT, 1 [3]
POWER SOURCE

UNIT DIMENSION
(HxWxD)
UNIT WEIGHT
COPPER PIPE SIZE

398,000

432,000

580,000

725,000

116,647

126,612

169,988

212,485

47,695
[86.3]

50,755
[89.5]

70,896
[121.8]

87,395
[150.5]

8.34 / 2.45

8.51 / 2.49

8.18 / 2.40

8.30 / 2.43

V/Ph/Hz

REFRIGERANT TYPE/CONTROL
EXTERNAL STATIC PRESSURE
AIR FLOW
SOUND PRESSURE LEVEL

380-415 / 3 / 50

TYPE
in.wg
CFM

R-407C / Indoor TXV

dBA

INDOOR UNIT
mm

OUTDOOR UNIT
INDOOR UNIT
LIQUID

mm/in

GAS

mm/in

1.83

1.53
15,000

1.63
18,000

68
1,546 x 2,274 x 1,466

70
1,978 x 2,274 x 1,905

(1,041 x 981 x 981) x 2 +


(1,142 x 1,083 x 1,083) x 2

(1,142 x 1,083 x 1,083) x 4


564

kg

OUTDOOR UNIT

YSB750B5
M4YSS150D x 5

Btu/h

A
Btu/h/W / W/W

EER

YSB600B4
M4YSS150D x 4

(184 x 2) + (197 x 2)
15.9 / 5/8
28.6 / 1-1/8 + 34.9 / 1-3/8

22,500
71
2,257 x 2,274 x 1,905
(1,142 x 1,083 x 1,083) x 5

991

1,051

197 x 4
15.9 / 5/8

268 x 4
15.9 / 5/8

268 x 4
15.9 / 5/8

34.9 / 1-3/8

34.9 / 1-3/8

34.9 / 1-3/8

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 13253.
3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
COOLING - 27C DB / 19C WB INDOOR AND 35C DB / 24C WB OUTDOOR.
4) SOUND PRESSURE LEVELS ARE MEASURED IN SOUND ROOM.

Roof Top

R407C

Y4RT60/80/100/120/150/200A

MODEL
TOTAL COOLING CAPACITY
TOTAL POWER
TOTAL CURRENT, 3
EER
POWER SOURCE
REFRIGERANT
AIR FLOW
SOUND PRESSURE LEVEL
DIMENSION (HxWxD)
UNIT WEIGHT
EVAPORATOR EXTERNAL
STATIC PRESSURE

Btu/h
W
W
A
Btu/h/W / W/W
V/Ph/Hz
TYPE
CFM
dBA
mm
kg

TOTAL POWER
TOTAL CURRENT, 3
EER
POWER SOURCE
REFRIGERANT
AIR FLOW
SOUND PRESSURE LEVEL
DIMENSION (HxWxD)
UNIT WEIGHT
EVAPORATOR EXTERNAL
STATIC PRESSURE

Y4RT60A
59,000
17,292
5,890
10.9
10.02 / 2.94

Y4RT80A
72,000
21,102
8,700
16.3
8.28 / 2.43

1,800
63
1,000 x 1,100 x 1,530

2,826
65

295

370

in.wg

MODEL
TOTAL COOLING CAPACITY

Y4RT250/300/360/420A

Btu/h
W
W
A
Btu/h/W / W/W
V/Ph/Hz
TYPE
CFM
dBA

Y4RT100A
95,000
27,843
11,600
20.2
8.19 / 2.40
380-415 / 3 / 50
R-407C
3,532
66
1,000 x 1,300 x 1,530

Y4RT120A
110,000
32,239
12,180
22.8
9.03 / 2.65

Y4RT150A
140,000
41,032
17,200
32.1
8.14 / 2.39

3,600
68

5,651
70
1,200 x 1,990 x 1,670

400

425

665

0.40

0.80

Y4RT200A

Y4RT250A

Y4RT300A

Y4RT360A

Y4RT420A

190,000
55,686
25,100
43.8
7.57 / 2.22

230,000
67,409
28,700
53.0
8.01 / 2.35

331,000
97,011
41,870
74.2
7.91 / 2.32

415,000
121,630
48,800
83.7
8.50 / 2.49

6,710
70

8,000

283,000
82,943
40,160
68.5
7.05 / 2.07
380-415 / 3 / 50
R-407C
9,300

mm
kg

1,200 x 1,990 x 1,670

in.wg

0.80

765

11,000

12,500

74

70

1,735 x 2,250 x 2,800


1,200
1,350

1,974 x 2,252 x 3,180


1,510
1,600

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 13253.
3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
COOLING - 27C DB / 19C WB INDOOR AND 35C DB / 24C WB OUTDOOR.
4) SOUND PRESSURE LEVELS ARE MEASURED IN SOUND ROOM.

1.0

10

Mini
Air-Cooled Chiller
R407C

Y4AC25/30C

Y4AC40/50/60C

Y4AC80/100/120/150C

Y4AC25C

Y4AC30C

Y4AC40C

Y4AC50C

Y4AC60C

Btu/hr

23,000

27,000

40,000

50,000

52,000

6,741

7,913

11,723

14,654

15,240

NOMINAL TOTAL INPUT POWER

2,949

3,679

4,910

5,955

6,859

NOMINAL RUNNING CURRENT- 1 [3]

13.60

17.40

[9.3]

[10.2]

[12.9]

Btu/hr /W / W/W

7.8 / 2.29

7.34 / 2.15

8.15 / 2.39

8.40 / 2.46

7.58 / 2.22

MODEL
NOMINAL COOLING CAPACITY

EER

REFRIGERANT

UNIT DIMENSION

220-240 / 1 / 50

V/Ph/Hz

POWER SOURCE

380-415 / 3 / 50
R-407C

TYPE
FLOW CONTROL

CAPILLARY TUBE

HEIGHT

mm / in

791 / 31.1

1,410 / 55.5

WIDTH

mm / in

1,179 / 46.4

1,160 / 45.7

DEPTH

mm / in

460 / 18.1

460 / 18.1

UNIT WEIGHT

kg /Ib

123 / 271

128 / 282

195 / 430

196 / 432

203 / 448

SOUND PRESSURE LEVEL

dBA

57

58

60

60

61

l/s / m/hr

0.32 / 1.2

0.38 / 1.4

0.56 / 2.0

0.70 / 2.5

0.73 / 2.6

0.32 / 1.2

0.38 / 1.4

0.70 / 2.5

0.73 / 2.6

7.5

8.7

EVAPORATOR
NOMINAL WATER FLOW
HYDRAULIC KIT
PUMP
PIPING
TANK

MAX. WATER OPER. PRESSURE

kPa / psi
l/s / m/hr

WATER FLOW RATE


INSTALLATION PIPE CONNECTION
HEAD

1,000 / 145
0.56 / 2.0

mm/in
m

25.4 /1
9.6

9.8

9.7
MILD STEEL COATED WITH ZINC

MATERIAL
L / ft

CAPACITY / VOLUME

22 / 0.78

40 / 1.41

Btu/hr

STAGE OF CAPACITY CONTROL

0% - 100 %
Y4AC80C

Y4AC100C

Y4AC120C

Y4AC150C

Btu/hr

74,000

88,000

115,000

137,000

21,688

25,791

33,705

40,152

NOMINAL TOTAL INPUT POWER

9,463

10,771

11,805

14,531

NOMINAL RUNNING CURRENT- 1 [3]

[17.3]

[18.0]

[23.6]

[27.9]

Btu/hr /W / W/W

7.82 / 2.29

8.17 / 2.39

9.74 / 2.86

9.43 / 2.76

MODEL
NOMINAL COOLING CAPACITY

EER

380-415 / 3 / 50

V/Ph/Hz

POWER SOURCE

R407C

TYPE

REFRIGERANT

TXV

FLOW CONTROL

UNIT DIMENSION

1,245 / 49.0

HEIGHT

mm / in

WIDTH

mm / in

1,500 / 59.1

DEPTH

mm / in

900 / 35.4

UNIT WEIGHT
SOUND PRESSURE LEVEL

1,800 / 70.9
1,150 / 45.3

kg / Ib

340 / 750

350 / 772

460 / 1,014

540 / 1,190

dBA

65

66

67

69

l/s / m/hr

1.08 / 3.9

1.31 / 4.7

1.67 / 6.0

2.00 / 7.2

1.08 / 3.9

1.31 / 4.7

1.67 / 6.0

2.00 / 7.2

19.4

16.7

EVAPORATOR
NOMINAL WATER FLOW
HYDRAULIC KIT
PUMP
PIPING
TANK

MAX. WATER OPER. PRESSURE

kPa / psi

WATER FLOW RATE

l/s / m/hr

INSTALLATION PIPE CONNECTION

mm/in
m

HEAD

1,000 / 145
42 / 1 1/4
22.6

20
NA

MATERIAL
CAPACITY / VOLUME

STAGE OF CAPACITY CONTROL

L / ft

NA

Btu/hr

0% - 50% - 100%

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 & ISO 13253.
3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
COOLING - 12C/7C ENTERING / LEAVING EVAPORATOR WATER TEMPERATURE, 35C AIR AMBIENT TEMPERATURE.
4) SOUND PRESSURES LEVELS ARE MEASURED IN SOUND ROOM.

www.york.com.my
Group Associated (C&L) Sdn Bhd (109719-M)
Head Office Tel: 03-7718 8388 Fax: 03-7727 4371
Email: sales_enquiry@york.com.my, customer_service@york.com.my
Branches:

Penang
Pahang
Melaka
Sarawak

Service Centre: Alor Setar

Tel: 04-331 1670


Tel: 09-567 6778
Tel: 06-288 1133
Tel: 082-333 299

Authorized dealer:

Johor
Tel: 07-557 7788
Perak
Tel: 05-548 2307
Sabah
Tel: 088-722 194
Negeri Sembilan Tel: 06-768 8969
Kota Bharu

Catalogue No: YODP-1012-E