Vous êtes sur la page 1sur 104

Esteem Innovation, 2013

Release Notes
8.5.13.0 (27 Sept 2013)
New Features!
1. Column can now be designed by considering upper floor reinforcement bar diameter and
count. No more lighter reinforcement at lower floor column. For more information,
kindly refer to User Manual > Parameters > Design.

2. Reload tracing drawing for faster modeling reference update. User can edit the original
tracing drawing (such as adding temporary reference lines and etc) and update it in
Esteem 8 with a single click of "Reload" button. No more hassle to unload, load and set
reference point again.

3. Add remark to each beam with the new "Beam Mark Suffix" property. Add customized
mark such as "U/S" for upstand beam "GB1(200x600)U/S". Show it on plan by changing
Project Parameter > Input > Beam > Show Suffix to True.

4. Backup to cloud storage for more secured data storage. User can now directly backup
Esteem 8 project file to cloud storage such as Google Drive and Dropbox. No more worry
about losing important model data and have more flexibility to share data. For more
information, kindly refer to User Manual > Main Menu > Backup > Google Drive /
Dropbox.

p1

Esteem Innovation, 2013

5. Wall Plan View is now linked to Wall Detailing and Full Report. Right click on any of the
wall panel to view detailing or full report for smoother verification of wall design.

6. Not Design status added to Wall Plan View. Look for new cyan color in wall plan view.

7. User can now predefine paper size for report. Default paper size is "Letter", go to
Project Parameter > Reporting > General > Paper Size to change the size.

8. Copied/Mirrored beam and slab will now use same mark plus suffix (') for ease of
reference. To generate new mark for copied/mirrored beam/slab, go to Project Parameter
> Input > Beam/Slab > Copy/Mirror Suffix and change it to False.

p2

Esteem Innovation, 2013

9. "Project Parameter > Detailing > Foundation > Pad/Pile > Section Detailing > Lean
Concrete Drawing Thickness" parameter is now removed. User may set lean concrete
thickness for foundation at Project Parameter > Quantity Take Off > Others > Foundation
> Lean Concrete Thickness (mm).

10. "Frame to Frame Spacing" option added to Beam Title Block Feature. User can now set
the vertical spacing between title block m easured from drawing boundary. For more
information, kindly refer to User Manual > Main Menu > Design Results > Multiple Beam >
Beam Title Block.

11. Filter option added to Tracking Changes report. User can now use this filter to
generate summary of element with changes. For more information, kindly refer to User
Manual > Main Menu > Design > Tracking Changes > Filter.

8.2.259.0 (10 June 2013)


1.

New Feature!

2.

New Feature!

Beam shear reinforcement design priority. User can now choose to


increase bar diameter or link loop as priority in beam design. For more information, refer
to User Manual > Parameter > Project > Design > Floor > Beam.
Foundation side bar reinforcement strength can now be customized
under Project Parameter > Detailing > Foundation > Pad/Pile > Section Detailing > Side
Bar Reinforcement.

New Feature!

Continuous column can now be displayed as detailing rather than


"Follow Top Column" text. Project Parameter > Detailing > Column > Detailing >
Continuous Column Display.
4. User can now batch export beam tabulated report.
3.

New Feature!

Foundation design with consideration of backfilled soil load. For


more information refer to User Manual > Parameter > Project > Design.
6. User can now toggle element appearance on key plan from right-click context menu.
7. Holding "Shift" key during beam input will invert the auto-connect beam parameter e.g. if
the parameter is set to enable auto-connect beam , holding "Shift" key will disable it.
5.

p3

Esteem Innovation, 2013

8.

New Feature!

9.

New Feature!

10.

New Feature!

Brickwall Auto Height feature to automatically compute brickwall


heights according to upper and lower floor element levels. For more information, refer to
User Manual > Main Menu > Input > Brickwall > Auto Height
Break Brickwall feature to break brickwall on a beam according to
different beam section drops or levels. For more information, refer to User Manual > Main
Menu > Input > Brickwall > Break Brickwall.
Beam reinforcement optimization can now be toggled on/off. User
can turn off to opt for beam design with lesser number of larger diameter rebar or turn on
for more number of smaller diameter rebar. For more information, refer to User Manual >
Main Menu > Parameter > Design > Floor > Beam.

8.2.69.0 Net 2 (2 Oct 2012)


1. User can now choose to view either Error, Warning or both by check/uncheck the boxes as
illustrated, below the Error/Warning list.

2.

New Feature!

3.

New Feature!

User can now have the option of having auto-connect beam turned
to True or False during input by going to Project Parameter > Input > Beam > General >
Auto-connect Beam.

Detailing for seismic case: Detailing provision for Seismic Load


Analysis (Static) case based on Eurocode 8 (EC8) is now available. The detailing provision
is available for code of practice EC2 and EC2 (NA to SS). For more information, refer to
o User Manual > Parameters > Project > 3D Analysis > Lateral Load Options >
Seismic Load Analysis (Static)
o User Manual > Parameters > Project > Design > Seismic Design

4. Grid properties' Begin Extension and End Extension is back in the latest release. User may
now either use Begin Extension and End Extension grid properties or the Extend Grid or
Trim Grid icon

5.

from Grid Input to extend or trim a gridline.

New Feature!

Pile footing detailing: Anchorage bars projecting from piles can now
be displayed in pile footing cut section detailing. For more information, refer to User
Manual > Main Menu > Parameters > Project > Detailing > Foundation > Pile > Section
Detailing > Pile Anchorage Bars.

p4

Esteem Innovation, 2013

6.

New Feature!

7.

New Feature!

8.

New Feature!

User can now customized the Prefix of Pile in the Pile List Selection.

Pile Mark Assignment can now be controlled in the Project Parameter


> Detailing > Foundation > Pile > Label > Pile Mark Assignment > By Default or By Pile
Number.

Beam/Slab can now be defined as ground beam/slab and can be


detailed with lean concrete.

p5

Esteem Innovation, 2013

9. Cantilever Slab Top Bar will be anchored at least 45 diameter into the beam from support
face. For more information, refer to Technical Documentation > Slab > Detailing >
Cantilever Slab with Drop.
10.

New Feature!

3D View object editing is now enabled. User can now change object
properties/delete object/copy column across floors in 3D View.

11. Batch Export output folder will now automatically open for user to check the output files.
12.

New Feature!

Torsion Reduction (Virtual Beam) is now available. User can now set
Torsion Reduction for wall framing beam element. For more information, refer to User
Manual > Main Menu > Parameters > 2D Analysis > Torsion Reduction (Virtual Beam)

13. Slab Point-by-Point Input can now be completed by "Enter" key.


14.

New Feature!

Input Precast Slab. User can now input Precast Slab which is similar
to Roof Slab Input and assign Load Distribution direction in X-Dir, Y-Dir or Both. For more
information, refer to User Manual > Object Properties > Slab > Customised Slab.

15. Beam is now checked for negligible compressive force. For more information, refer to User
Manual > Parameters > Project > Design > Floor > Beam > Design Specification >
Allowable Axial Compressive Force, %
16.

New Feature!

Project Costing is now available. For more information, refer to User


Manual > Parameter > Quantity Take Off. Open Costing from the tab below for each
p6

Esteem Innovation, 2013

element and project.

17.

New Feature!

18.

New Feature!

19.

New Feature! Beam Tabulated Report is now available. For more information, refer

Copy Cut Section: Slab cut section can now be copied to another
floor(s). For more information, refer to User Manual > Main Menu > Input > Slab > Create
Cut Section.
User can change the slab fill appearance to be according to Slab
Drop Value, Dead Load Value, Live Load Value, Self-Weight Value for the ease of slab
input checking. The option can be accessed through Main Menu > View > Slab > Slab Fill
by.

to User Manual > Parameter > Reporting > Beam Tabulated Report. Open Report from the
tab below for each Beam.

20. Beam Stiffness Increment parameter is now removed. All projects will run without any
beam stiffness adjustment in the latest release.
21.

New Feature! Application and Projects based setting now both can be import and
export. For more information, refer to User Manual > Parameters > Project.

22.

New Feature! Grid Marks Elbow. User can now set the grid marks to have elbow
with user defined length.

23.

New Feature! Hide All Grids: To hide all the gridlines on the keyplan in the project.
Refer to User Manual > Main Menu > Input > Grid for more information.

24.

New Feature! Beam Cut Section can be grouped. Refer User Manual -> Parameters
-> Detailing -> Beam -> Cut Section -> Cut Section Grouping for more information.

25. Adoption of BS8110 Part 1 Clause 3.4.5.12 in beam design.


26.

New Feature!

Upper Column in Subframe. Users now have the option whether to


include or exclude upper column in the 2D sub-frame analysis. For more information, refer
p7

Esteem Innovation, 2013

to User Manual > Parameters > 2D Analysis.

8.0.549.0 Net 2 (28 Oct 2011)


1. Column plan-based detailing: Steel percentage provided for columns can now be shown in
the Column Detailing -> Plan-based Detailing.

2. Total Number of Pile points is now being displayed on pile detailing with the control of the
parameter in Project Parameter > Detailing > Foundation > Pile > Others > Show Pile
Point Counts > True.

p8

Esteem Innovation, 2013

3. Slab Result. The Full Report and Summary Report for individual columns' Punching
Shear checking are now available in Design Result -> Slab. The punching shear checking
is available for projects having either flat slab columns or columns sitting on transfer
slabs. Refer to User Manual -> Design Results -> Slab -> "Punching Shear Checking
Report" for more information.

4. A minimum diameter of 12mm is now compulsory for columns longitudinal reinforcement


in accordance to BS8110:1997 Clause 3.12.5.3.
5.

New Feature!

6.

New Feature!

7.

New Feature!

Texture and Hatch Pattern for Brickwalls. User can now select
different appearance for bricks to help user to identify different brick types in 3D model
and plan view. The parameter is available under Project Parameter > Material > Brick
Properties.

Typical Column Elevation Detailing. User can now select to include


typical column elevation detailing. The parameter is available under Project Parameter >
Detailing > Column

Beam Title Block. User can now load title block drawing into Multiple
Beam Detailing and all the beams selected will be arranged automatically. For more
information, refer to User Manual > Main Menu > Design Results > Multiple Beam > Beam
Title Block

p9

Esteem Innovation, 2013

8.

New Feature!

9.

New Feature!

10.

New Feature!

11.

New Feature!

Pre-Analysis Report. Before analysis the building User can ensure


that Parameters, Load Combinations, Storey Loads and Materials have been correctly
defined. For more information, refer to User Manual > Verification > Pre-Analysis Report
Slab Opening Detail. User can now obtain Slab Opening Details. For
more information, refer to User Manual > Main Menu -> Input -> Slab -> Rectangular
Opening
Shear in Columns. Column will not design to Shear and Torsion
when M/N value fulfill requirement in Part 1 Clause 3.8.4.6 for all load Cases. For more
information, refer to Technical Documentation -> Shears in Columns.
New parameter for Quantity Take Off (QS) in Project Parameter >
Quantity Take Off. User can now define steel density and foundation lean concrete
thickness for QS calculation.

12. Foundation excavation calculation is now based on column/wall stump height. Previous
calculation is based on stump height of 500mm.

13.

New Feature!

14.

New Feature!

Generate Column Marks


, previously column marks are assigned
during column design. Now, user can generate column marks during input. For more
information, refer to User Manual > Main Menu > Input > Column > Generate Column
Marks.
Input Roof Slab (i.e. slab with 0 thickness). User can now input Roof
Slab and assign Load Distribution direction in X-Dir, Y-Dir or Both. For more information,
refer to User Manual > Object Properties > Slab > Customised Slab.

8.0.488.0 Net 2 (25 July 2011)


1.

New Feature!

Feature to generate point loads on multiple columns now available.


The command is available through the Column Input's right-click context menu. Refer to
the User Manual -> Main Menu -> Input -> Column -> Context Menu for more
information.
p10

Esteem Innovation, 2013

2.

New Feature!

3.

New Feature!

User may now check for any latest updates for Esteem 8 General
Release through Help menu -> Check Updates. This link will direct user to the Download
page for "Esteem 8 Software Updates".

Minimum Number of Piles can now be applied individually for


Column Pile Foundation in the Object Viewer.

p11

Esteem Innovation, 2013

4.

New Feature! Show All Grids: To show all the gridlines on the keyplan in the
project, including all the hidden gridlines. Refer to User Manual -> Main Menu -> Input ->
"Grid" for more information.

5.

New Feature!

Archi Import Auto Locate Feature: Auto generate region for element
that cannot be import due to short of grid intersection as reference point. Refer to User
Manual -> Main Menu -> View -> Architectural Drawing -> Import -> Parameter(Drawing
Import) -> Grid -> Grid Region -> Auto Loc ate.

6. Show Floor Level : To show stump and floor level in Pile and Pad Footing Section
Detailing. Refer to User Manual -> Main Menu -> Parameters -> Project -> Detailing ->
Foundation -> Pad -> Section Detailing and User Manual -> Main Menu -> Parameters ->
Project -> Detailing -> Foundation -> Pile -> Section Detailing under "Show Floor Plan"
and "Stump Height" for more information.

7.

New Feature!

Column mark will now be locked after first batch process. User may

p12

Esteem Innovation, 2013

rearrange column mark using Rearrange Column Marks


Column Rearrange.
8.

function. Input -> Column ->

New Feature!

Column clear height computation can now be based on Clear


Distance between End Restraints. To turn on, change Project Parameter -> Design ->
Column -> Column Clear Height from Clear Floor Height to Clear Distance between End
Restraints. For more information, refer to User Manual -> Parameters -> Design ->
Column -> Column Clear Height.

9. Curved beam intersecting with existing beam will now be able to input. User may need to
convert it to straight beam segments in order to pass project integrity check.

8.0.385.0 Net 2 (30 March 2011)


1. Further improvement in the detection of restraint elements to the wall in the calculation
for wall effective height. Refer to Technical Documentation -> Wall -> Wall Effective
Height for more information.
2. Updates on column input on raft. Refer to Technical Documentation -> Raft for more
information.
3. User now has the option to specify the parameter for Coefficient of Moment of Inertia for
all element types; slab, beam, column and wall. Refer to User Manual -> Main Menu ->
Parameters -> Analysis Setting -> Coefficient of Moment of Inertia.

4. Floor selection for drop down list is added for Search Element function. Refer to User
Manual -> Main Menu -> View -> Search Element.

5. Parameter in 2D Analysis -> T-Beam Effect has been removed. This will be applied to any
p13

Esteem Innovation, 2013

new project created in the latest release.


6. Modification of Column Result Diagram control panel to show bottom floor 2D results.
Refer to User Manual -> Main Menu -> Design Result -> Column -> Result Diagram for
more information.

floor
7. Grid properties' Begin Extension and End Extension have been hidden. User may continue
to use the Extend Grid or Trim Grid icon
gridline.

from Grid Input to extend or trim a

8. Icon for Object Snap Setting now available. Refer to User Manual -> Tools -> Snap
p14

Esteem Innovation, 2013

Settings for more information.

9. Column that is not stump and not supported by any element will now pass verification
with warning message.

10. Slanting beam marking now available. User may change slanting beam prefix in Project >
Slanting Beam Prefix. Refer to User Manual > Object Properties > Project for more
information.

11. Column failed in link design now included in column fail report.

12. Intersecting beam point load now shown in beam loading diagram.

13. Slab brickwall can be input without 0 - 300mm limitation from another Brickwall/Load and
slab edge and brickwall length can less than 300mm if Project Parameter -> Analysis
Setting -> Slab Equivalent Nodal Load is set to TRUE.

14. Mirrored/Copied grid will be mark as the same and differentiate by apostrophe sign ('). For
example, a new grid mirrored or copied from grid A will be mark as A'. For multiple
duplications, new grids will be named as A'', A''' and so on.

15. Slanting beam result diagram now can be viewed in Elevation Result. Activate Elevation
Result command and click on any slanting beam to display result diagram for the beam.
p15

Esteem Innovation, 2013

For more information, refer to User Manual > Main Menu > Analysis Result > Elevation
Result.

16. Subframe view elements and nodes information will be displayed in the object viewer as
an element is selected from the display by mouse click. For more information, refer to
User Manual > Main Menu > Analysis Result > 2D Contour View > Subframe view.

8.0.300 Net 2 (29 Nov 2010)


1. Alternative Deflection Check (for cantilever beam only). The program will do an alternative
deflection check (BS8110:1997 clause 3.4.6.3) for cantilever beam when the cantilever
beam fails in the deflection check by using span/depth ratio (BS8110:1997 clause
3.4.6.3).
2. Slab top bar detailing: Tick length for dimension has been shortened.

3. Option to turn off the label for top bar location is now available in Project Parameters ->
Detailing -> Slab -> Detailing -> Show Top Bar Location.
Slab top bar location is turned on
Slab top bar location is turned off

4. The critical value of displacement can be shown in 3D Analysis by right-click> show max
node only

p16

Esteem Innovation, 2013

5. "Wall" will be indicated on beam detailing if beam is supported by wall

6. Detailing of pad foundation for column link will be drawn all the way up

Previous version

Latest version

6. New Parameter for user to define Column Mark to be shown in exported Key Plan.
p17

Esteem Innovation, 2013

8.0.290.0 Net 2 (15 Nov 2010)


1. Released nodes for slab in 3D Mesh now can be displayed through right-click context
menu. For more information, refer to User Manual -> Main Menu -> Analysis Result -> 3D
Analysis Result.

2. Default color for wall mesh (in 3D Analysis Display) has been changed.

Previous version:
p18

Esteem Innovation, 2013

8.0.271.0 Net 2 (22 Oct 2010)


1. Batch Export for Raft Punching Shear Summary and Full Reports now available.
2. Updates in the calculation of relative stiffness for curved beam s framing into columns. For
more details, refer to Technical Documentation -> Column -> Column End Conditions (Out
of plane cases) -> Curved beam framed into column.
3. User may now set the maximum relative stiffness for computation of column beta value.
For more information, refer to User Manual > Parameters > Design > Column > Maximum
Relative Stiffness
. For more
4. User may now input column across multiple floors using Advance Input
information, refer to User Manual > Main Menu > Input > Column > Advance Input.
5. Slanting beam is now available in beam toolbar. For more information, refer to User
Manual > Main Menu > Input > Beam > Add Slanting Beam.
6. Option for Beam Grouping is now available. For more information, refer to User Manual >
Parameters > Project > Detailing > Beam > Grouping
7. Option for Rebar Editing now available in Design Result -> Single Beam -> Beam Rebar
Editing.

8. Option to Group Column now available in Project Parameter -> Detailing -> Column ->
Grouping -> Group Column = T RUE.

p19

Esteem Innovation, 2013

9. Column/wall sitting on a transfer slab can now be done. Refer to Technical Documentation
-> Transfer Slab for more information.

10. Tracking Changes, Tracking Records, and Compare Tracking Records are now available in
Design menu/toolbar. For more information, refer to User Manual > Main Menu > Design
> Tracking Changes.
11. New shortcut key for QS Comparison, (CTRL + E, V). For more information, refer to User
Manual > Main Menu > Design Results > Quantity Take Off > QS Comparison.
12. Beam Rebar Editing feature is now available in Design Result > Beam Rebar Editing
mode.

p20

Esteem Innovation, 2013

8.0.243.0 Net 2 (21 Sept 2010)


1. Option to provide top bar for pile cap is now available. For more information, refer to User
Manual -> Parameters -> Design -> Project -> Pile.
2. Slab Stiffness Adjustment by default is set to 100. For more information, please refer to
User Manual> Parameters> 2D Analysis> Slab stiffness adjustm ent.
3. Linetype scale factor for key plan construction drawing is now available in Project
Parameter -> Drawing -> Plan Drawing -> Linetype Scale Factor

For more information, refer to User Manual -> Parameters -> Drawing -> Linetype Scale
Factor.
4. Linetype scale factor for detailing drawing is now available in Project Parameter ->
Detailing -> Linetype Scale Factor

p21

Esteem Innovation, 2013

For more information, refer to User Manual -> Parameters -> Detailing -> Linetype Scale
Factor.

8.0.208.0 Net 2 (29 July 2010)


1. Pad footing design: Option for using single bar diameter in pad footing design now
available in Project Parameter -> Design -> Project -> Pad -> Main Reinforcement -> Use
Single Bar Diameter.

p22

Esteem Innovation, 2013

For more information, refer to User Manual -> Parameters -> Design -> Project -> Pad ->
"Use Single Bar Diameter".
2. Pad & Pile Section Detailing: Reinforcement strength for side bar diameter < 10 will now
automatically switch to 'R' bar. For more information, refer to User Manual -> Parameters
-> Detailing -> Foundation -> Pad and User Manual -> Parameters -> Detailing ->
Foundation -> Pile.
3. Export Wall/Column Reactions report is now available. For more information, refer to User
Manual -> Main Menu -> Analysis Result -> Wall and Column Reactions
4. Minimum Bent Length for Pin and Fix condition can be specified by user individually in
beam detailing. This feature is under Project Parameter -> Detailing -> Beam -> Bar Bent
5. Some shortcut keys have been changed as shown below:
Before:

D = Grid.
F = Beam.
G = Slab.
H = Column.
J = Wall.
N = Brickwall.
M = Elevation.
< = Move to left icon.
> = Move to right icon.
After:
Ctrl + Shift + D - Grid.
Ctrl + Shift + G - Beam
Ctrl + Shift + H - Slab
Ctrl + Shift + J - Column
Ctrl + Shift + V - Wall
Ctrl + Shift + N - Brickwall
Ctrl + Shift + M - Elevation
Ctrl + Shift + < - Move to left.
Ctrl + Shift + > - Move to right.

8.0.198.0 Net 2 (14 July 2010)


1. Beam End Option button is now available with 3 options (Auto, Pin, Fix). For more
information, refer to User Manual -> Main Menu -> Input -> Beam.
2. Shortcut key to bring up "Search Element" form now available. For more information, refer
to User Manual -> Esteem User Interface (UI) > Esteem Short Cut Keys.
3. Shortcut keys now available for full screen mode, and to toggle for grid, beam, slab,
column, wall, brickwall and elevation input. For more information, refer to User Manual >
Esteem User Interface (UI) > Esteem Short Cut Keys.

4. Boundary points of a slab area can now be shown while the slab is being selected.

p23

Esteem Innovation, 2013

5. Measure function is now available at elevation input view. Right Click > Measure Length to
activate or deactivate the function.

8.0.156.0 Net 2 (31 May 2010)


1.

New Feature!

Convert curved beams into straight beams: The feature helps to


convert curved beam into straight beam segments with predefined segment length. This
feature overcomes the Verification -> Plan Integrity error where curved beam is not
supported on columns. Previously, user has to click on the intersections one by one to
input the straight beams simulating the curved beams. For further details, refer to topic in
User Manual -> Main Menu -> Input -> "Curve Beam".

2. Input slab between curved beams fixed. As the feature "Convert to Straight Beams" above
is now available, user can input the slab in between the curved beams converted into
straight beams as shown in example below. Refer to topic in User Manual -> Main Menu
-> Input -> "Curve Beam" for further details.

8.0.153.0 Net 2 (25 May 2010)


1. Wall Full Report: The column for Loading Source now included in the tabulation for wall
braced/unbraced condition.
2.

New Feature!

Slab support design: To skip collecting the node values within


column profile is now available. Refer to Technical Documentation ->Slab ->Design

p24

Esteem Innovation, 2013

3.

New Feature!

4.

New Feature!

Strut and Tie method in transfer wall: Option for design of short
transfer wall is now available. Refer to Technical Documentation -> Wall -> Wall Detailing
-> "Not design due to short transfer wall" for further details.

Punching Shear Calculator: Type "Auto" is now available to


automatically detect the colum n type, whether internal, edge or corner column. For
further details, refer to User Manual -> Main Menu -> Tools -> Punching Shear Calculator.

8.0.109.0 Net 2 (7 April 2010)


1. 3D View: "Disable Pads and Piles" is removed from the 3D View's context menu because it
is redundant. The hiding/displaying of the pads and piles in the 3D View can be done by
floor basis. Refer to User Manual -> Main Menu -> 3D View for further details.

2. Bug in Raft Punching Shear report fixed: The lateral load results for the design moment
Mt1 and Mt2 were not tabulated correctly.
Example: Tabulation of design moments Mt1 and Mt2 for lateral load cases were not
tabulated correctly.

p25

Esteem Innovation, 2013

Version before 8.0.104.0 Net 2

Version 8.0.104.0 Net 2 onwards

3. Bug in Raft Punching Shear report fixed: The results for the design shear, Vt, ultimate
shear capacity, Vcap and design effective shear, Veff were not tabulated correctly when
there is no Column Point,
beneath the column sitting on
the raft foundation.
Example: The value of Vt were not captured correctly in the Raft Punching Shear Report
for column sitting on raft without a Column Point for the column on the raft floor below.

Plan View
Plan View
Version before 8.0.103.0 Net 2

Version 8.0.103.0 Net 2 onwards


p26

Esteem Innovation, 2013

4. Indication of beam section support number when slab failed in flexural design of slab top
bar. For further details, refer to User Manual -> Main Menu -> Design Results -> Failed
Elements.

5. Indication of Load Case of the occurrence of the node with large displacement in 2D
Subframe View. Previously, the Load Case of occurrence is only shown in 3D Analysis
Display. For further details, refer to User Manual -> Main Menu -> Analysis Result -> 2D
Contour View -> Subframe View.

8.0.88.0 Net 2 (22 March 2010)


New Features!
1. Converting EsteemPlus project to Esteem8: The 'Beam drop with slab' feature in
EsteemPlus is converted to Esteem8 by setting the beam's drop to the touching slab's
drop. For more details, refer to User Manual > Main Menu > Import > Beam Drop with
Slab.

2. Parameter to control the minimum steel percentage for fabric in the transverse direction
now available. User is now able to control the minimum percentage of rectangle fabric
reinforcement (for Type B) in the transverse direction. Previously, the fabric reinforcement
was mainly based on the Minimum Steel Percentage, %. For further details, refer to User
Manual > Paramters > Design > Floor > Slab.

p27

Esteem Innovation, 2013

3. Identical beam marks in projects imported from Esteem Plus to Esteem 8. Since Esteem 8
does not allow identical beam marks as in Esteem Plus, the program will automatically add
a combination of character '*Serial Number' to those beams with identical beam mark
during import from Esteem Plus into Esteem 8. For further details, refer to User Manual >
Transitioning from Esteem Plus > Identical Beam Mark.

4. 'Delete Element' icon has been updated as shown in figure below. Previously the 'Delete
Element' icon was represented by 'X' icon.
Previously
Latest version

5. 3D analysis results from Stage Construction now available in Single Beam > Results
Diagram. The analysis results can be obtained from the 3D Frame Analysis when Stage
Construction = TRUE. For further details, refer to User Manual > Main Menu > Design
Result > Single Beam > Result Diagram.

6. Warning message for columns that failed due to no restraint and thus subjected to large
beta value and applied moment. Previously there was no message indicating the reason of
the large applied moment. This warning message is included in the "Full Report" and list
of "Failed Elements". Refer to User Manual > Main Menu > Design Results > Failed
Elements for further details.
Mx and My is taken with respect to the geometrical centroid of the column
Applied Axial Load = 208.8 kN
p28

Esteem Innovation, 2013

Applied Bending Moment about X-X Axis = 217.3 kNm


Applied Bending Moment about Y-Y Axis = 1.8E+308 kNm
Bending moment due to effect of slenderness is excessive because there is no restraint at x or y axis of the column

8.0.67.0 Net 2 (23 Feb 2010)


New Features!
1. The "Table of Contents" for ALL textual reports such as Full Report, Summary Report,
Loading Report, etc. are now available for easy browsing. The list in the "Table of
Contents" will automatically help user to browse through the report of that particular
element by clicking on the topic in the list. For further details, refer to User Manual > Main
Menu > Design Results > Single Beam.

2. Steel Area Required for slab detailing can be shown on plan. Please refer to User Manual>
Parameters> Detailing> Slab.
3. Slab cut section on plan can be shown in different direction. Please refer to User Manual>
Parameters> Detailing> Slab> Cut Sec tion On Plan
4. Design of elements using 2D Analysis results is not allowed if there is any transfer
element exists in the project. Therefore, user is informed initially by disabling Batch
Process Plan (2D) > ALL element design. Previously, user is only informed after 2D
Analysis is completed. Refer to User Manual > Main Menu > Analysis > "Batch Process"
topic for further details.

5. Feature to measure angles on display is now available on the right-click context menu of
the display. Refer to User Manual > View > Architectural Drawing > "Open a View" for
further details.

p29

Esteem Innovation, 2013

6. Size of cover that drawn for slab detailing can be defined by user without following the
real cover setting. Refer to User Manual> Parameters> Detailing> Slab for further details.

7. Improvement of Auto-Fix feature to autom atically solve Large Displacement nodes


especially for cantilever beam sections PINNED at support. Refer to User Manual > Main
Menu > Verification > Auto-Fix Changes for further details.

8. In addition of Staged Construction, both 3D Non-Staged Construction and Staged


Construction analysis results for regions above wall opening are included in Wall Detailing
> Full Report.
o 3D Non-Staged Construction analysis results:

o 3D Staged Construction analysis results:

9. Option either to use Transfer Beam's Staged Construction or Full Non-Staged Construction
3D Analysis result is now available in Project Parameter > 3D Analysis > Stage
Construction > Transfer Beam = TRUE/FALSE. Refer to User Manual > Parameters > 3D
Analysis > Stage Construction > "Transfer Beam" for further details.

p30

Esteem Innovation, 2013

10. The row of inner ties in column reinforcement schedule can now be toggled On/Off
through a new parameter called "Show Inner Ties" in Project Parameter > Detailing >
Column > "Show Inner Ties" = True/False. For further details, refer to topic in User
Manual > Parameters > Detailing > Column.

11. The 2D unfactored dead load and live load is now available in Design Result for beam. The
result is shown in Design Results > Single Beam > Beam Result > Result Diagram tab. In
the Result form, choose 2D Plan Analysis and 2D Raw Result: Dead Load or Live Load.

12. Parameter to control beam end release condition updated. The beam end release setting
for beam ends sitting on another beam is now controlled by another parameter in Project
Parameter > Analysis Setting > "Beam End Release Beam". Previously, beam end sitting
on another beam is controlled by Beam End Release at Support. For further details, refer
to topic in User Manual > Main Menu > Input > Beam > "Beam End Condition".

p31

Esteem Innovation, 2013

8.0.34.0 Net 2 (4 Jan 2010)

1. Raft Punching Shear report for raft foundation. The raft punching shear report is available
in Design Result > Raft Punching Shear menu.

p32

Esteem Innovation, 2013

2. Indication of both Outer Ties and Inner Ties in column reinforcement. The reinforcement
for Outer Ties and Inner Ties are now shown in Column Reinforcement Schedule and Plan
Based Detailing.
Column Reinforcement Schedule
Plan Based Detailing

3. Implementation of Raft Foundation. For more information on the implementation, refer to


Technical Documentation > Raft.

4. Customized Support condition for individual stump now available. Refer to User Manual >
p33

Esteem Innovation, 2013

Object Properties > Column > Stump Properties for further details.

5. Transfer wall with opening and transfer wall without side support will be marked as Not
Designed. Refer to User Manual > Design > Design Wall > Strut and Tie Method for
further details.

6. Bug where the column reduction factor was not updated in the analysis and causing the
column to fail in the analysis is now fixed. (fixed in version 7.6.71. C Net 2.0 onwards).
Meaning, unbraced slender columns which failed previously in analysis will now pass
because it is now able to update the reduction factor used in reducing the moment in the
analysis. Refer for summary of "Design/Analysis Result and Status" below for comparison.
Previous Release
Design / Analysis Result and Status
No
Process
FCap
FApplied
MyApplied
MzApplied
Status
Fail Mode
1
Analysis
14443.6
15799.7
316.0
3823.5
Fail
Capacity
2
Analysis
9.5
9.5
105.7
2.3
Pass
None
3
Design
18590.2
15984.5
111.2
1925.8
Pass
None
4
Analysis
5903.5
141.5
111.2
34.2
Pass
None
5
Analysis
13433.0
10796.0
-1214.0
2612.6
Pass
None
Latest Release 7.6.71.0 C Net 2.0 onwards
Design / Analysis Result and Status
No
Process
FCap
1
Design
18502.3
2
Analysis
434.1
3
Analysis
18590.2
4
Analysis
5903.5
5
Analysis
14672.5

FApplied
15799.7
9.5
15984.5
141.5
10796.0

MyApplied
101.1
101.1
111.2
111.2
-1214.0

MzApplied
1944.5
2.3
1925.8
34.2
2085.6

Status
Pass
Pass
Pass
Pass
Pass

Fail Mode
None
None
None
None
None

7. Column Design Full Report: Indication of short or slender column. Another c olumn is now
added in the tabulation of "Selection of Moment for Design and Analysis" to indicate
whether the column is short or slender for every load case.
p34

Esteem Innovation, 2013

DESIGN / ANALYSIS RESULT


Selection of Moment for Design and Analysis
My
No
2D/3D NeMin Mi Madd Selected Slender
1 101.1
101.1
No
2 101.1
101.1
No
3 111.2
111.2
No
4 111.2
111.2
No
5 -1214.0
-1214.0
No

2D/3D NeMin
0.0
316.0
0.0
0.2
0.0
319.7
0.0
2.8
0.0
215.9

Mi
0.0
0.0
0.0
0.0
0.0

Mz
Madd
1944.5
2.3
1925.8
34.2
2085.6

Selected Slender
1944.5
Yes
2.3
Yes
1925.8
Yes
34.2
Yes
2085.6
Yes

Note
2D/3D - Moment values obtained from 2D/3D analysis process, kNm
NeMin - Moment due to minimum eccentricity x design ultimate axial load, kNm
Mi - Initial moment at the point of maximum additional moment, kNm
Madd - Additional Moment induced by deflection, kNm
Selected - Selected moment based on greater of 2D/3D, NeMin and Mi + Madd, kNm

7.6.115. 0 C. Net 2 (20 Nov 2009)


1. Bug when not able to detect two loop link in Quantity Take Off for column solved.
2. Columns at wall end detailing. The end bars are anchored fully into the columns.
Previously, the end bars were not anchored into the columns.

3. Beam detailing. Tension lap will be used when there is a sagging moment at the support.
The 2D Full Moment will be used to decide whether tension or com pression lap is used. For
more details, go to Technical Documentation > Beam > Detailing > "Use tension bar
lapping for sagging moment at support".
4. 2D Contour View. The contour values will be displayed when moving mouse along the
contour.

p35

Esteem Innovation, 2013

5. Input General Variation Load on top of RC Wall now available. For further details, refer to
User Manual > Input > Wall > General Variation Load.
6. 3D Wall Contour. Arrow of Principal Stress Max, Pmax and Principal Stress Minimum, Pmin
has been removed to avoid confusing direction of the stress paths. v7.6.83.0 Net 2.0
7. Individual setting for potential couple beam to be meshed as area (shell element)is now
available in Object Viewer > Beam > 3D Analysis > Use Deep Beam Mesh> True. This
parameter will overwrite the global parameter in Project Parameter > 3D Analysis >
Couple Beam Depth. For further details, refer to User Manual > Object Properties > Beam
> 3D Analysis > Use Deep Beam Mesh.
8. The static secant modulus of elasticity of concrete, Ec can be defined manually or
automatically from the Characteristic strength of concrete, fcu. Previously, the Ec cannot
be defined manually.
9. 3D Wall Contour Cut : Cut section for wall contour can be done which previously cannot.
Refer User Manual < Main Menu < Analysis Result < 3D Analysis Result < 3D Wall Contour
< 3D Wall Contour Cut.

p36

Esteem Innovation, 2013

10. Grid Input UI : The sign of distance in Y-direction has been reversed. For further detail,
refer User Manual < Main Menu < Input < Add Grid.

11. Prevent multi-instance users opening a single license of Esteem7. User is no longer
allowed to open more than one Esteem7 application simultaneously. Therefore only ONE
application is allowed to be opened at once.
12. Improvement of wall opening couple beam cut section detailing.

p37

Esteem Innovation, 2013

13. Change in curve slab top bar detailing. The top bar over the support is extended to the
curve slab. Previously, top bar is also provided in the curve slab, causing congested
detailing in the curve slab area.
Curve slab top bar detailing

14. Enhancement of Material and Design Data in reports for every element slab, beam,
column, wall, pad and pile by including the value of Static Secant Modulus of Elasticity of
Concrete, Ec (N/mm2)

MATERIAL AND DESIGN DATA


Code of Practice

fcu (N/mm)

Ec, (N/mm)
p38

fy (N/mm)

Esteem Innovation, 2013

BS8110 : 1997
Cover (mm)
25

25

22454

460

Conc. Unit Weight (kN/m)


24

1.5

1.05

Steel Unit Weight (kg/m)


7860

15. Wide Couple Beam meshing: Meshing of couple beam with more than one row of mesh.

16. Only Single line for the edge of the link indication if turn to False in Project Parameter>
Detailing> Beam> Shear and Stirrup

17. Enhancement of Column design Full Report for clearer presentation to user.
Selection of Moment for Design and Analysis
My
Mz
No
Selecte
2D/3D
NeMin
Mi
Madd
2D/3D
NeMin
Mi
d
1
0.1
0.2
0.0
2.2
2.3
0.5
0.3
0.1
2
0.1
0.1
0.0
1.4
1.5
0.5
0.2
0.1
3
-0.1
0.4
0.0
6.0
6.0
-0.2
0.9
0.1
4
-0.1
0.3
0.0
4.1
4.2
-0.2
0.6
0.1

Madd
1.1
0.7
3.0
2.1

Sele
cted
1.2
0.8
3.1
2.2

18. The titles for 2D and 3D Contour View is shortened to DIS, Mx, My, etc.

19. Beam top bar detailing: Tension lap is used for top bar detailing (where there are hogging
moments). Previously, compression lap was used for top bar since the lapping is located at
the point of change of moment sign.

p39

Esteem Innovation, 2013

20. Enhancement of slab Analysis Report. The maximum values are highlighted in the
tabulation of node values from the 2D Contour View. The location of the node values are
also referred to as according to either Sagging or Hogging moments (which are not
located on boundary of the slab region).
Example:
Analysis values (Sagging) of region (all nodes)
Moment X Local Maximum = 4.68 kNm
Moment Y Local Maximum = 7.55 kNm
Shear Force X Local Maximum = 0.00 kN
Shear Force Y Local Maximum = 0.00 kN
Displacement Maximum = 1.184 mm
Analysis values (Hogging) not on boundary of region
Moment X Local Maximum = -3.75 kNm
Moment Y Local Maximum = -15.91 kNm
Shear Force X Local Maximum = 0.00 kN
Shear Force Y Local Maximum = 0.00 kN
Refer to Right-Click menu on a Slab Panel > View Analysis Report to view the
enhancements.
21. Checking of column slenderness about respective axis as per Clause 3.8.1.7 and 3.8.1.8 in
BS8110: 1997 now included in Column Detailing > Full Report. However, in previous
version the column would still fail Automatically due to huge slenderness moment applied.
The comparison is shown below:
version before 7.6.54.0 Net 2.0
Slenderness Calculation About Y-Y Axis
Column Clear Length, lo = 7510.0 mm
Lateral Force, V = 0, Use Stability Index Q = 0 for Gravity Load
The Element is Braced
Relative Stiffness at Top of Element, Top = 0.000
Relative Stiffness at Bottom of Element, Bot = 1.000
1 = 0.7 + 0.05 (Top + Bot) = 0.75
2 = 0.85 + 0.05 Min (Top, Bot) = 0.85
= Min (1, 2) = 0.75 < 1.0
Effective Length = leff = lo = 5632.5 mm
leff / H = 5632.5 / 125.0 = 45.1 >= 15
The Column Is Slender About Y-Y Axis
Deflection of column under ultimate condition, au = a Kyy Hyy
Iyy = 36621093.8 mm^4
ryy = (Iyy / Ac) = (36621093.8 / 28125.0) = 36.1 mm
a = (leff / ryy) / 24000 = (5632.5 / 36.1) / 24000 = 1.02
p40

Esteem Innovation, 2013

Initial Kyy value = 1.0


Eccentricity, eMin = H / 20 = 125.0 / 20 = 6.3 mm 20 mm

--------------------------------------------------------------------------------

Design Failed
Design Process Failed.
Capacity of section insufficient!
(As Required / As Provided) Ratio, K from last iteration =
2.29
version 7.6.54.0 Net 2.0 onwards
Slenderness Calculation About Y-Y Axis
Column Clear Length, lo = 7510.0 mm
Lateral Force, V = 0, Use Stability Index Q = 0 for Gravity Load
The Element is Braced
Relative Stiffness at Top of Element, Top = 0.000
Relative Stiffness at Bottom of Element, Bot = 1.000
1 = 0.7 + 0.05 (Top + Bot) = 0.75
2 = 0.85 + 0.05 Min (Top, Bot) = 0.85
= Min (1, 2) = 0.75 < 1.0
Effective Length = leff = lo = 5632.5 mm
leff / H = 5632.5 / 125.0 = 45.1 >= 15
The Column Is Slender About Y-Y Axis
Deflection of column under ultimate condition, au = a Kyy Hyy
Iyy = 36621093.8 mm^4
ryy = (Iyy / Ac) = (36621093.8 / 28125.0) = 36.1 mm
a = (leff / ryy) / 24000 = (5632.5 / 36.1) / 24000 = 1.02
Clause 3.8.1.7 Slenderness limits for columns
lo / Min(b, h) = 7510 / 125 = 60.1 > 60
Slenderness Limit is exceeded
Initial Kyy value = 1.0
Eccentricity, eMin = H / 20 = 125.0 / 20 = 6.3 mm 20 mm
---------------------------------------------------------------------------------------------------------------------

Design Failed
Design Process Failed.
Capacity of section insufficient!
Slenderness limit by code of practice exceeded
(As Required / As Provided) Ratio, K from last iteration =
2.29
22.

Warning

Any version before 7.6.42.0 for the transfer wall(Not whole length
of wall) sitting on the intersecting beam does not plot the Shear and Moment diagram
correctly. It will cause the shear force and m oment which is taken in the 3D analysis
might be not correct.

p41

Esteem Innovation, 2013

However, it Doesn't Affect the wall which is in full length(With Continuous Shear Wall) that
sitting at the intersecting beam .Only the wall(With Breaking Shear Wall) sitting at the
intersecting beam, the shear force and moment diagram are interpreted wrongly.

p42

Esteem Innovation, 2013

With
Continuous
Shear Wall

3D shear force and moment diagram on beam 6F63 (Correct)

With
Breaking
Shear Wall

3D shear force and moment diagram on beam 6F63 (Wrong)

You can study the example "Transfer shear wall at intersecting beam (With Breaking Shear
Wall) & Transfer shear wall at intersecting beam (With Continuous Shear Wall)" provided in
the installation CD under sub-folder "\Projects" for clarity.
Open the project. Batch run 2D and 3D analysis with beam design. Observe the shear force
and moment from Design Result> Single Beam> 6F63> Result Diagram> 3D Frame Analysis
23. Re-arranged the location of 'Add Point Load on Column' icon for clarity and consistent with
Wall Point Load input.
24. Allowable Percentage is available in Project Parameter> Design> Project> Pile to let user
to set the percentage whether to allow the large footing is designed which the self-weight
itself can cater for tension situation. Please refer to docum entation in UserManual> Main
p43

Esteem Innovation, 2013

Menu> Design> Pile Footing> Allowable Percentage.


25. User can choose either envelope moment or most critical case moment to run the Pile
Design. Please refer to documentation in UserManual> Main Menu> Design> Pile Footing>
To Use Envelope Moment Run Pile Design
26. User can choose either envelope moment or most critical case moment to run the Pad
Design. Please refer to documentation in UserManual> Main Menu> Design> Pad Footing>
To Use Envelope Moment Run Pad Design
27. Indication of moment in Pad Footing when there is moment.

28. Column offset and column marks are now shown in foundation detailing. Column marks
will only be shown after Column Design is done.

29. Auto-connect beams. Implemented for beams that are being input ONLY along the same
gridlines in section but not as a whole beam. Refer to User Manual > Main Menu > Input >
Beam > Merge for further details.
30. Improved integrity checking when new Grid Region is added at the same point of an
existing Region. This is to avoid overlapping regions.
31. Bug in beam stirrup detailing for small beam section near support face fixed (inaccurate
distance for link placement which was taken from centre of support).
32. Enhancement on Beam Detailing. Grid Circle and Grid Line are separate entities. Link and
Link Range Line are separate entities.

p44

Esteem Innovation, 2013

33. Grid Mark and Grid Circle to be separate entity. User can view this new layer in Project
Parameter > Drawing > Layer Settings

7.6.21.0 C .Net 2 (3 Sept 2009)


1. Shear and Torsion Design Calculation for beam: Tension steel area provided now shown in
Full Report.
Tension Steel Area Provided = 603 mm
- Table 3.8: Values of c, design concrete shear stress
Steel Percentage, 100 As / (bv d) = 0.361 % < 3.0 %

2. Wind Load Input Comply to CP65 is now available. Please refer to User Manual > Main
Menu > Input > Lateral Load > Wind Load Value and Technical Documentation > Loading
> Wind Loading > Wind Load Input Comply to CP65 for further details.
3. Report enhancement for beam called Summary Report is added in the batch export.

4. When Free Node Check is TRUE and click to Generate Mesh, a warning message will pop
up to notify user the number of free nodes found in the mesh. Previously no warning
message pop up to notify user.

5. Input range for Multiple Grid Input distance is now increased to -50000mm to 50000mm.
Previously input range was only from -10000mm to 10000mm.

p45

Esteem Innovation, 2013

6. Vertical help line in Elevation Input to help user align the wall opening precisely

7. To show the slab cut in the key plan. Set True for Slab Cut in Project Parameter> Drawing
Arrangement

8. Beam detailing span cut. The parameter for beam detailing span cut is now available in:
Project Parameter > Detailing > Beam > Span Cut. Refer to User Manual > Parameter >
Detailing > Beam > Span Cut for further details.
Beam detailing before Span Cut

Beam detailing after Span Cut

p46

Esteem Innovation, 2013

9. Wall design: Indication of steel percentage in calculation for both Full Report and
Summary Report.
Full Report
Sub-Panel Applied Axial Force, F = 138.6 kN
Sub-Panel Axial Force Capacity, FCap = 15142.6 kN
Sub-Panel Applied Moment About X-X Axis, Mx = 0.0 kNm
Sub-Panel Moment Capacity About X-X Axis, MxCap = 0.0 kNm
Sub-Panel Applied Moment About Y-Y Axis, My = 0.0 kNm
Sub-Panel Moment Capacity About Y-Y Axis, MyCap = 0.0 kNm
Wall Sub-Panel Analysis/Design Passed
Vertical Reinforcement Provided: 36T12-1-275 (0.41%)
Summary Report
Wall Design Summary Table
Group
Floor
Core ID
Panel
ID
gb

1/A-B

Sub-Panel

V-Rebars

H-Rebars

Sub Panel 1 36T12-1-27


2X
(Reg. 1)
5 (0.41%) 10T10-300

Status

Remark

Pass

10. Default Legend text size for 2D Contours and 3D Contours are now enlarged.

p47

Esteem Innovation, 2013

11. Allowable range for column and RC Wall stump height is between 500mm to 30000mm.
Previously no maximum limit for the c olumn and RC Wall stump height.
12. New specification for the distribution of Torsion Longitudinal perimeter bar. Refer to topic
in Technical Documentation > Code of Practice > BS8110: 1985 only > Distribution of
Torsion Longitudinal Perimeter Bar for the details and example.
13.

New Feature!

Slab thickness indication in Floor Keyplan and Slab Detailing. The


slab thickness shown on floor keyplan is now only the one which is different from the
U.N.O (Unless Noted Otherwise). Refer to User Manual > Object Properties > Plan for
further details.
Floor Key Plan
Slab bottom/top detailing

p48

Esteem Innovation, 2013

14. Bug in Slab Cut Section detailing for internal panel now fixed (slab cut for internal panel
shows slab is discontinuous although slab is continuous).
15. Now when user set Beta value for column manually through Object Viewer, the default
value will be 1.0. Previously the default value is zero (0). With this new setting, it will
always return to the default value 1.0 whenever the value entered is not within the range
allowed.

16.

New Feature!

Tracing an architectural drawing: With this new feature, two


drawings can now be viewed on a keyplan.
Eg: To do Tracing based on the current floor, upper floor or bottom floor for comparison.

17. Enhancement in Multiple Architectural Drawing import. Now Incremental Import for Grid is
applicable for addition of new grids on an amended drawing. Refer to User Manual > Main
Menu > View > Architectural Drawing > Import > Multiple Import of Architectural Drawing
for further details.
18. Default setting for Beam End Release Support is now Pinned. If any large displacement
issue arises, the auto-fixing of the large displacements can now be overcome by using the
Auto-Fix feature.

p49

Esteem Innovation, 2013

19.

New Feature!

20.

New Feature!

Floor name now shown in: a) Keyplan (input display), b) Slab top
and bottom bar detailing.

Showing of upper and lower beams, slabs, brickwalls and walls from
upper and lower floor now available! Refer to User Manual > Main Menu > View > "Show
Objects from Upper Floor" and "Show Objects from Lower Floor" for feature details.

21. Correction in the Characteristic Strength used for stirrup bar in Shear and Torsion
Reinforcement for beam design when using smallest bar, R.
Now whenever the link bar diameter is using the smallest bar, R, it will use the
Characteristic Strength of Stirrup bar specified in:
o Parameter > Design > Special Design > Characteristic Strength of Stirrup Bar,
regardless of the parameter "Maximum Beam Width".

22.

New Feature!

Shortcut keys to toggle element marks now available in "Beam


Results" mode! By default, now only the beam markings are shown to avoid congested
plan display of "Beam Results" mode. Other element marks can be turned on when needed
using their respective shortcut keys.

p50

Esteem Innovation, 2013

23.

New Feature!

24.

New Feature!

25.

Warning

Auto detects the com mon source of problems for large displacement
issue through Auto-Fix!
Refer to topic in User Manual > Verification > Auto-Fix Changes for more details.

Applied loadings on beams are now shown on keyplan!

Bug of discrepancy between slab top bar detailing and detail


calculation in Full Report in version before 7.5.147.0 C Net 2.0.
Refer to example of top bar detailing for slab FS29 below:

o In slab detailing, no "Design Fail" warning shown

p51

Esteem Innovation, 2013

o But in Full Report and Failed Element list, the slab actually "Failed in Flexural
Design of Slab Top Bar for Slab".

FEM Slab Analysis Result for Support 254


Design Bending Moment from FEM Analysis = -61.47 kNm/m
Unfactored Displacement from FEM Analysis = 0.1632 mm
Design Calculation for Support 254
RC Wall Mark = LC0: Bi/7a1G-6a
Slab/Sub-Slab Mark = FS29:1
Thickness of Slab = 150 mm
Average Concrete Stress above Neutral Ax is, k1 = 0.40 30.0 = 12.12 N/mm
Concrete Lever Arm Factor, k2 = 0.4518
Limiting Effective Depth Factor, cb = 0.50
Limiting Concrete Moment Capacity Factor, kk1 = cb k1 (1 - cb k2)
= 0.50 12.12 (1 - 0.50 0.4518) = 4.691N/mm
k2 / k1 Factor, kkk = 0.037
Mu / bd = 61.5 1000000 / (1000.0 109.0) = 5.174 N/mm
Mu / bd = 5.174 > 4.691
Design for singly reinforced failed and cannot design as doubly reinforced
Design Failed, not able to provide reinforcement

26. The Out of Memory message will notify user when the project is running out of memory.
Refer to FAQ > Error Message > Out of Memory, for further details.

p52

Esteem Innovation, 2013

27. Now, there is an error message to notify user if wrongly defined brickwall height (where
new minimum height should be 100mm, in milimeter). Previously when user mistakenly
assume that the input value is in meter (say, 5m height brickwall. User might input 5
instead of 5000), no error message is shown to notify user.

28. The below model will show Free Node after analysis due to Alternative Model in Project
Parameter been turned to TRUE (For Esteem 7.5.160 below).

However the problem is solved in Esteem 7.5.160


29. For short beams not connected to slab, now the midpoint is created to get the exact
midspan moment. For example:

Previous version

Current version

p53

Esteem Innovation, 2013

30. Notify user the governing minimum torsion link spacing as specified by the code without
failing in torsion design.
Previous version

Current version

31. Now, the diagonal grid can be copied either to the floor below or floor above.

32. Rotation of Main Grids in every Regions are now not allowed. Thus all the Main Grids in
Regions must be in 90 degrees.

33. Enhancement in beam detailing. Reduce numbers of lapping at the bottom layer of
reinforcement. If the bar size is the same, the bar will be pulled over without lapping.
Previous version

p54

Esteem Innovation, 2013

Current version

34. Enhancement in beam detailing. The grid line and lapping lengths are now more compact.
The cut sections are shifted away from the labels to avoid overlapping layers.
Previous version

Current version

p55

Esteem Innovation, 2013

35. Auto locking of beam intersections in the verification checking.

Previously the beams ends with such configuration would cause an error message for user
to check and modify their model manually as shown below.

36. When the foundation failed in design due to uplift force, user needs to refer to Footing
Design Loading Table in Full Report to identify uplift force himself.

37. Additional statement is now shown for the design that governs the link spacing provided
as shown below in Beam Result > Full Report > Shear and Torsion Design Calculation.

38.

Governed by

Statement

Buckling check

Shear Reinforcement Provided : T10-125 (Link spacing is governed by buckling check)

Maximum spacing
defined by user
setting

Shear Reinforcement Provided: T10-250 (Link spacing is governed by user setting)

Torsion
reinforcement

Shear And Torsion Reinforcement Provided : T10-175 (Link spacing is governed by


torsion)

New Feature!

Flush brickwall to the left, right or centre of beam is now available!


Refer to User Manual > Main Menu > Input > Brickwall for more details.

39. Hardlock properties can now be viewed through Help Menu > Hardlock Properties.

p56

Esteem Innovation, 2013

40. Improved Beam Result Diagram form: All-in-one sc reen:

41. Lapping and anchorage for side bar

42. Rebar spacing warning in Beam Full Report can now be turned On/Off in Parameter >
Detailing > General > Rebar Spacing Warning.
Warning, Top spacing between steel bars is insufficient, minimum clear spacing required by user is 30 mm

43. Column rotation can now be snapped to a gridline. Refer to topic in User Manual > Main
p57

Esteem Innovation, 2013

Menu > Input > Column > Column Rotate.

44. Wall effective height calculation: Consideration of transverse beam and transverse wall.
The stiffness of each restraint element at the top and bottom of wall zone are tabulated
accordingly. Refer to examples provided under topic "Wall Effective Height" in Technical
Documentation.

Slenderness Result
Wall Clear Height, lo = 6600 mm
Top Element Stiffness, KeTop = KsTop + KbTop + KtwTop = 2529228.6 mm
Bottom Element Stiffness, KeBot = KsBot + KbBot + KtwBot = 7762500.0 mm
Wall Stiffness, Kw = 1610795.5 mm
Restraint Elements at the top part of wall zone
Elememt
No.
Mark
Width a, mm Depth b, mm
Type
1
Slab
FS1:1
3150
115
2
Beam
2B1(125x600) - 1
125
600

Length L,
mm
3000
7800

Angle ,

90.0
90.0

798459
1730769

Note
K = 0 when the element is skipped from computation of restrain condition, please refer to the technical documentation
K = |Sin | [a b / (2 L)]

Restraint Elements at the bottom part of wall zone


Elememt
No.
Mark
Width a, mm Depth b, mm
Type
1
Beam
GB6(200x600) - 1
200
600
2
Beam
GB37(125x300) - 1
125
300

Length L,
mm
3000
3000

Angle ,

90.0
90.0

7200000
562500

Note
K = 0 when the element is skipped from computation of restrain condition, please refer to the technical documentation
K = |Sin | [a b / (2 L)]

45. Enhancement in rc wall reporting: Wall short/slender condition tabulation.

46. Wall is designed for gravity and lateral loading cases. Thus not able to determine in which
load case does the wall is in tension or compression. To solve this problem, the area of
reinforcement used in shear design for wall will now use 0.15% which is more
conservative for all the loading cases (version 7.5.96.0 onwards).

p58

Esteem Innovation, 2013

47. Enhanced and more compact reporting in Wall Shear Design Checking Calculation .

48. The loading shown on pad footing detailing is the equivalent design service load,
(equivalent column load + pad footing self-weight). Please refer to User Manual > Main
Menu > Design Results > Pad Footing > Detailing for detailed explanation.

7.5.84.0 C .Net 2 (11 May 2009)


1.

Warning

Bug in the calculation of K (reduction factor that corrects the


deflection to allow for the influence of axial load) fixed for wall design. The bug is more
prominent in cases of longer slender wall as additional slenderness moment is a
function of K and h (height of wall). The incorrect calculation of K will result in a lower
slenderness moment hence rendering the wall to be under design. This bug was fixed in
version 7.5.44.0 onwards.
You can study the example "Slender wall design-7.5.42.0-2503091201.zip" provided in
the installation CD under sub-folder "\Projects" for clarity.
Open the project. Batch run 2D and 3D analysis with wall design.
Click "Design Report > Wall" and check on the summary report.

Wall Design Summary Table


Group
Floor
Core ID
Panel
ID
1b

A/1-2

Sub-Panel

V-Rebars

H-Rebars

Status

Remark

Sub Panel 1
(Reg. 1)

26T32-50

2X
23T10-250

Fail

Wall Failure due to


inssuficient section
capacity

The wall would fail in design.


If you create the same model and repeat the same steps mentioned above in version lower
than 7.5.44.0 you will find that the wall will pass in design.

2.

Warning

: Any version before 7.5.7.0 does not take into consideration the 3D

Analysis results for the shear/torsion design of beams. Critical it will cause under design in
shear/torsion of transfer wall partially sitting on transfer beam as the design of this beam
requires the 3D results which is not taken into account.

p59

Esteem Innovation, 2013

You can study the example "Partial transfer wall-7.0.362.0-0705091447.zip" provided in the
installation CD under sub-folder "\Projects" for clarity.
Open the project. Batch run 2D and 3D analysis with beam design. Observe the shear force
from the "Plan Loading and Result Diagram"
2D shear force diagram on beam gb1

3D shear force diagram on beam gb1

Open the beam design full report and check the shear & torsion design calculation.

SHEAR & TORSION DESIGN CALCULATION


LOCATION : SECTION 1 LEFT SUPPORT
(B:0 mm E:1500 mm from left grid of span)
Maximum Torsion within Zone, T = 19.6 kNm
Shear at Location of Maximum Torsion, V = 251.8 kN
p60

Esteem Innovation, 2013

The design shear of 251.8 kN is taken correctly from the 3D analysis results.
If you run the same model with a version lower than 7.5.7.0 you will discover that the 2D
analysis results will be chosen hence the bug!
When the wall sits across the whole length of the beam between the column, the strut and tie
method would be employed to design the beam hence beam is deemed safe. In cases of
transfer columns the accumulation of loading from all upper floor 2D analysis are generally
more conservative than the 3D analysis results. User are advice to check and satisfy
themselves with the design results.
This bug has been fixed from version 7.5.7.0 onwards.
3. Slenderness ratio of wall design is now checked against "Limits of Slenderness" (version
7.5.89.0).
4. Beam mark using grid info as mark previously not shown in design report is fixed.
5. Column On Beam(COB) must now be fully supported to integrity chec k.(Figure 2 &
Figure 3)

Figure 1 : The error message will warn user regarding the COB is not fully supported

Figure 2: The COB is Not Fully Supported

Figure 3: The COB are Fully Supported


6.

Reminder

To avoid multi-grids at intersection as in example in the model


below, user gird trimming.

p61

Esteem Innovation, 2013

This is to avoid the element locking into different nodes, to prevent inaccurate meshing. User
can trim grid lines to such an extent that it does not produce unnecessary grid nodes
(generated at intersection of grid lines) using trim gridline

7. Continuous column (not from lowest floor) going down to foundation support condition
now strictly follows the 3D column support parameter.
8. Wall restraint information window pops up at the right click command of a wall selected.
9. Beam mark parameter "Show Dimension" default set to TRUE.
10.

New! QS
1.1.

Obtained from menu "Design Results > Quantity Take Off"


Quantity take off for beam reinforcement.

1.2.

Quantity take off for column reinforcement.

p62

Esteem Innovation, 2013

1.3.

11.

Incremental select possible for QS. At input menu, select elements, then right
click to Update QS. Only selected elements will be accounted for in the QS
table.

New! A faster and more efficient solver has been implemented. Sample performance as
follows (vertical axis in hours).

12. Implemented wall restraint info as context right click option when a wall is selected.
13. Unfactor beam reaction now shown in beam details, "Full Report" and "Summary Report".

BEAM SUPPORT REACTION TABLE


Current Beam Grid Mark: C
Beam Support Reactions
Support No.

Grid Mark

Support Type

1
2
3

3A
5
6

Column
Wall
Wall

Support Reaction, kN
Dead Load
Live Load
12.3
3.1
22.3
5.0
5.2
0.4

14. Torsion reduction parameters default set to 99% for both 2D and 3D Analysis.
15. 3D Analysis parameter: Alternative model is now defaulted to TRUE for all new projects.
16. Node value report (Beam) can now be produced.
p63

Esteem Innovation, 2013

17. Dongle number is now display in the splash screen from menu Help > About Esteem 7.
18. General improvement in the speed of input for beam, slab and column.
19. View Beam mark setting relocated from main menu View > Beam to Project Parameter
> Input > Beam.

20. "Single mark" beam mark view option now gives you the flexibility to m ark beams. Applies
only to multi-span type view. The first span would have the beam mark with beam section
dimensions of that span while the rest of the spans with the section dim ensions only.

21. Parameter: Detailing > Beam > Bar Mark > Additional Text default to TRUE. User will be
informed of torsion link design if applicable.

p64

Esteem Innovation, 2013

p65

Esteem Innovation, 2013

7.5.16.0 C .Net 2 (22 Feb 2009)


New Features! in Esteem 7.5
1. 3D Analysis now has the option to simulate the Stage Construction effects of
column/wall shortening using sequential Floor Dead Load application. See topic in user
manual "Stage Construction" under the Parameters sub-topic.
2. Design of plain wall available. Select a wall or walls in plan and edit "Design > Wall
Type" in object viewer to opt for plain wall design.

3. Additional feature in Architectural Import/Tracing: Multiple import from


drawings over an existing key plan. The feature overcome the limitation of architectural
import process. Previously, user can only perform the architectural import once for each
plan. Now, this feature can be use over multiple times.
4. Option for wall detailing using fabric reinforcement.
5. Inability to detect grid line discrepancy of less than 1 mm fixed.
6. Option to select BRC as top reinforcement bar for slab hogging moment at support. This
can be done via clicking on the slab support location in the slab top detailing form and edit
the options for fabric detailing at the object viewer.
7. Identification of load case added in the large displacement list in "3D Analysis Display"
form.

8. [2008_1127:2008_1231][$X$END_CON9]
9. Feature to Auto break a wall panel when there is an intermediate column support on the
lower floor.

Check user manual topic "Auto Break Wall" for further details.
10. Warning now provided in beam design report when the top or bottom bar spacing is
insufficient (this is checked against the minimum clear spacing is provided in the
parameter by the user). Previously, beam design will failed.
11. Enhancement to the top bar curtailment strictly follow span basis, including handle of
multiple spans with or without drops. For further details, see topic "Top Bar detailing rules
" in the Technical Documentation.

p66

Esteem Innovation, 2013

12. General improvement in response speed of column, beam, slab, wall, brickwall and slab in
plan input.
13. Bug in OSnap (Intersection) function fixed (inaccurate osnap position when function called
after performing first click on "Region" command).
14. Beam Detailing: Beam Side Bar Draw Full Line Parameter default to TRUE.
15. General improvement of presentation in pile c ap dimension detailing.
16. Slab will not be meshed in "3D Mesh" if it is supported on two adjacent edges.

17. Upper and lower floor (new feature) objects like columns, walls can now be both
displayed.

18. Slab cuts defined in "Plan Input" and "2D Contour Display" are mutually exclusive. They
are not synchronised.
19. Wall group now has a mark such as the example below to facilitate easy identification in
the "Column / Wall Reaction" form.

20. Improvement in critical case labeling in Column Calculator design result output.

p67

Esteem Innovation, 2013

21. Design reports are now not editable within the application.

7.0.362.0 C .Net 2 (13 Nov 2008)


1. Beam end condition "Auto" to pin the beam ends when there is no support (column or
wall) AND when overlapping depth profile less than 100 mm. In situation where
there are multiple beam ends without support, one instance of the conditions mentioned
being met would result in all the beam ends at this node be pinned.
a. Beam end fixed

b. Beam end pinned

p68

Esteem Innovation, 2013

2. Quantity Takeoff expanded to include breakdown of slab, beam, column, RC Wall, pad
footing and pile footing.

Note: Reinforcement quantity not included.

3. General improvement on 3D Analysis Result form (incorporating results per floor for large
memory model).
4. Enhancement of cut section input in 2D Contour form
Additional features:
* Arbitrary cut section

* Incremental selection
* Window select style based on AutoCAD rules a) Window select from left to right - section only will be selected only if whole
section is windowed
b) Window select from right to left - section will be selected if part of the
p69

Esteem Innovation, 2013

section is windowed

7.0.354.0 C .Net 2 (4 Nov 2008) - interim release


1. Esteem 7 now runs under .Net 2 platform with 64-bit computing capabilities enabling it to
handle large memory model.
2. Show Beam Dimension parameter defaults to "TRUE" for all new projects.

3.
4. Enhancement in cut section input in "2D Contour" form.
5. Tool tip will pop up when mouse moves over cut section number in 2D Contour form.

6. Parameter: Side cover (Distance (mm) from concrete surface to side bar surface) default
to 50mm. New parameter added: "Rebar to Pile" (Distance (mm) from steel bar surface to
pile cut-off surface).

p70

Esteem Innovation, 2013

7. If 2D mesh unstable, 2D sub frame view will pop up automatically. If 3D mesh unstable,
3D Analysis Display view will pop up automatically.
8. Pile schedule table sort in ascending order by Pile capacity follow by Pile nos.

9. "Large Memory" option introduced in "Plan Loading and Result View" and "3D Analysis
Display". Esteem 7 will automatically detect large memory requirement and check this
option. Checking this option enables the user to quickly view results by per floor basis.

10. Multi-intersecting beam ends without support will now be "Pinned" if the end condition is
set to "Auto". User will have option to input beams with its ends "Pinned" with the "Beam
End Option"

from "Beam Input".

p71

Esteem Innovation, 2013

11. Distribution of nominal moments (calculated based on nominal top bar of beam) to upper
and lower column.
12. Bug in "File > Open" (Error message "Inconsistent Project State") of v337 fixed.
13.

.Net 2 release
Installing Esteem 7 .Net 2 version
The following pre-requisites are or may be needed.
1. Microsoft Windows Installer 3.1
This may be found in the Esteem 7 installation sub-folder "Prerequisites" as a file called "
WindowsInstaller-KB893803-v2-x86.exe".
If this file is missing, you can also download it from Microsoft website.
2. Vector Draw converter.
This may be found in the Esteem 7 installation sub-folder "Prerequisites" as a file called "
vdLiteFileConverter.msi"
3. Dot Net 3.5 components.
This may be found in the Esteem 7 installation sub-folder "Prerequisites" as a file called "
dotnetfx35.exe".
If this file is missing, you can also download it from Microsoft website
http://download.microsoft.com/download/6/0/f/60fc5854-3cb8-4892-b6db-bd4f42510f28/
dotnetfx35.exe
Clicking on the

p72

Esteem Innovation, 2013

will initiate the setup process. The program will check whether the
required components above are already installed on your computer and installed them
accordingly. If this automatic process fails, installed the two com ponents manually first from
the "Prerequisites" folder and re-do from "Setup.." process thereafter.

How do I install the eLock Driver on a 64-bit system?


The 64-bit eLock Driver Installation Guide
After installing Esteem 7 on a 64-bit Windows XP, the software might not be able to find the eLock and
thus cannot be started. Additional steps need to be done to resolve the problem.
1. Install Esteem 7 as usual.
2. Plug in eLock. If it is already connected to the USB port, unplug it and then plug in again.
3. You will see the following dialog. Select Yes and then click Next.

4. You see then see the following dialog. Choose Install the software automatically and then press

p73

Esteem Innovation, 2013

Next.
5. Then the system starts to search for relevant drivers on the computer. This may take a while.

6. After that you a Hardware Installation dialog appears. Just click Continue Anyway to proceed.

p74

Esteem Innovation, 2013

7. You will come to the final dialog which indicates that the driver has been properly installed. Click
Finish to complete the installation process.

7.0.337.0 C .Net 1 (9 October 2008)


1. Pin Support (Column) parameter default value set to TRUE for 3D Analysis.

p75

Esteem Innovation, 2013

2. A message will appear to non-existence of hardware lock.

3. Flexural shear check on most critical section included in foundation design report.
4. Pile coordinates based on local axis as shown in Pile Design form.15598

5. Correction done to enhanced shear capacity calculation which was halved in release
7.0.301.0 C. Additionally, pile force is based on cut off of pile profile area as illustrated in
the example below:

p76

Esteem Innovation, 2013

Full force of pile no. 1 and 3 is used when the cut line goes beyond 50% of the pile profile
area.
6. "Use Torsion Perimeter Bar" Default Setting is now set to "TRUE".

7. vc (design concrete shear stress) = 0 when the tension force of beam > 0.05fcu.Ac where
Ac is the gross sectional area of the beam section.
8. Column offset dimension featured in "Column Detailing" form under "Plan-Base Detailing"
tab.

p77

Esteem Innovation, 2013

9. Application of

m = 1.15 when high yield steel grade greater than 499 eg. 500 N/mm2 is

specified in the material parameter as in accordance to Am endment 3 of BS8110:Pt. 1


1997.
10. Depth of beam between joined beam section to adopt the shared depth (d) but not less
than 100mm in the design of section.

7.0.301.0 C (28 August 2008)


1. Dimension line and dimension text are now in different layer to facilitate production of
hardcopy line thickness according to colour.

2. In Pad footing detailing, the loading shown is the most critical load combination which
is used in
the design of the pad footing (see user manual topic Design Results > Pad footing >
Detailing).
3. Bug in DXF/DWG files labels of detailing entities (multiple or redundant line or other
entities) resolved.
4. Slab marking for single sub-slab now appears as eg. "FS1" instead of "FS1:1".
5. General UI speed improvement due to platform optimisation.
6. Added "Analysis Info" into "Tools" on main menu.

p78

Esteem Innovation, 2013

7. User input flange beam parameters from beam properties grid for flange beam design
implemented.

8. Option to have beam section name to follow beam marking. This will have to be set from
the beam property grid of the object viewer.
9. Checking of unused gridlines: performance improvement.
10. "Service Load" button added to "Pad" foundation results form called out from Project
Explorer.

11. Brickwall loads with similar begin and end height, UDLs and Point loads will not be deleted
when a beam with these loads applied is broken. See online help topic, "Loadings on a
broken beam" for further details.
12. New feature in 3D Analysis. The "Alternative Model" parameter will employ a
"closed-form" beam model.

p79

Esteem Innovation, 2013

l
13. New parameter introduced in Design>Floor>Beam>Shear Reinforcement, "External Loop".

p80

Esteem Innovation, 2013

14. New feature introduced: Compare Gridlines in Tools>Gridlines Utilities

15. Batch Export Report.

p81

Esteem Innovation, 2013

16. Column grid mark now shown in Column Summary Report or Column Failure Report.

17. Curtailment Dimension Style can now refer to gridlines in slab cut sections details.
18. "Check Project Free Node" feature is introduced. This command is available from
p82

Esteem Innovation, 2013

Verification->Project->Check Project Free Node.


19. Batch Export Drawing to include colum plan based detailing

20. "Watermark" on display when either Elevation or 3D View out of synchornization with the
plan. The text "Out of Sync. Press F12 to refresh" will be shown in Elevation Input view or
the 3D View.

21. Gridlines of two floors can be compared with command, Tools->Gridlines


Utilites->Compare Gridlines
22. Column dimensions are now shown in Column Calculator.

p83

Esteem Innovation, 2013

23. Batch exported drawings files will have version suffixes.

24. "Bend down of bottom bar" feature allowed by parameter setting

p84

Esteem Innovation, 2013

25. Slab cut mark can now be renamed by editing on the object viewer after double clicking
the mark.
26. Slab cuts can be found using "Search Element" command from the "View" menu.
27. The "Search Element" button is implemented on the standard toolbar,

28. Slab drop is displayed on floor plan.

29. New command from right click upon gridline selection that is "Copy grid to floor above".

7.0.188.0 C (23 April 2008)


1. Beam mark interpretation explanation added for the architectural import feature in the
help file. Search using keyword "beam mark import".
2. Pressing F1 calls up help file topic when cursor is at any individual parameters of its
category (Grid, Beam, Column, Brickwall, RC Wall) for Architectural Import parameters.
3. DEL key can be used to edit gridline dimension text.

p85

Esteem Innovation, 2013

4. Improvisation in the Save As... command (saving specification as per Microsoft Word
concept). Check online help for further details.
5. Some bugs fixed for roofline load distribution method.
6. Reference Height in Wind Load Value form validation fixed to half-height of each floor.
7. New feature: Column detailing on plan.

8. Grid regions can now be individually selected to be shown or not through


from the Grid toolbar. A selection window will appear when the Region Selection is
clicked.

p86

Esteem Innovation, 2013

9. Beam failure message in report are now more specific eg. "Failure due to Bottom Bar Clear
Spacing".
10. Footing detailing: Column starter bars links. It willl now show at least two links.

11. Individual grid region can now be selected to be visible or not. Also each grid region
element's colour can be customised.

p87

Esteem Innovation, 2013

12. Element design results available from Project Explorer

13. T-Beam Effect parameter can be assigned onto individual beams through the property
grid.
14. Column mark is now shown in foundation key plan.

p88

Esteem Innovation, 2013

15. Beam design bypass: If a beam for some reason cannot be design (program logic issues),
the design process will bypass it and proceed to the beam element rather than halting the
whole process.
16. Wall opening group selection editing in elevation input is now possible.
17. A label denoting the program is in the Measure mode will appear as a useful reminder.

18. Introduction of feature "Free end node". This feature will assist user to diagnose structural
instability or disconnected meshing. Available in "2D SubFrame View".

19. Beam Cut Section applies to beam span between supports; see "Beam Property under
Beam Design->Cutline. (Previously was between sections of beams).
20. Curtailment Dimension Style can now refer to Grid.

p89

Esteem Innovation, 2013

21. Provision of "Closed Link" label for link designed for torsion.

22. Identifying close nodes in 2D mesh. Use in 2D mesh view over key plan to locate nodes
which are closer than specified in the 2D Analysis parameter to diagnose quality of mesh
as and when required.

7.0.133.0 C (22 February 2008)


1. Individual slab design report can now be called out.

p90

Esteem Innovation, 2013

2. Beam names in "Beam Group Detailing" (Design Results->Mutiple Beam) is now sorted
according to ascending order.

3. Modified Basic Span Depth Ratio parameter is introduced. This modified basic span/depth
ratio will be use in the design to identified a cantilevered behaviour beam in the deflection
check. To view the formulation, search for "MBSDR" in the online technical documentation.
4. MyApplied and MzApplied column moments are added to the "Design/Analysis Result"
table of the Full Column Design Report.

p91

Esteem Innovation, 2013

5. 3D meshing of bridging beam at wall/column intersection revised.

3D View of model

3D mesh of bridging beam of wall/column intersection


6. Able to printout hardcopy for 2D contour cuts.
7. Thickness of beam UDL increased.

8. General bug fixes to the roofline method of load distribution.


9. "Fly" option in 3D View. When this option is checked, the model can be "spin" by clicking
the mouse and drag in the direction intended.

p92

Esteem Innovation, 2013

This feature required high end graphics hardware. By default is is unchecked.


10. Slab stiffness reduction parameter is added.

Default from preset value in Parameters.

11. T-beam property and slab stiffness property can now be individually edited. For example,
for a beam not monolithic to any slab,

we can edit the "T-Beam" parameter from the object viewer.

12. User will be prevented from deleting any file in the project folder and its sub-folders when
p93

Esteem Innovation, 2013

the project is opened. If for some reason user is able to delete any project files, there
would be no guarantee the file(s) will be restored. As a matter of factly, the project could
be corrupted and nothing could be done to retrieve the deleted file(s).
13. Failed elements to be listed automatically when its design form is called out.

7.0.113.0 C (4 February 2008)


1.

Layer names for pad and pile footing is now differentiated.

2.

Gridline granularity 25 and 50mm precision added.

3.

Column IDs are now shown on the pad and pile foundation plan detailing.

4.

Revised UI for Safety Factor

5.

Differentiation of presentation between failed and passed pad/pile design in 3D View.

6.

Pile Selection list can now be saved as templates.

p94

Esteem Innovation, 2013

7.

Introduction of beam label based on gridline system.

8.

Introduction of parameter to control the grid mark & dimension lines distance.

p95

Esteem Innovation, 2013

9. Slab nodes moment release at wall edges.


When there is a slab discontinous supported by a wall, the slab nodes will have moment
release. The following parameter will effect this feature.

Set the "Release Slab Nodes On RC Wall" to TRUE. Slab nodes will be pinned according the
specification mentioned above with the exception of cantilever slabs.

p96

Esteem Innovation, 2013

The circular symbols denoting releases will be shown in the mesh view.

7.0.91.0 C (28 December 2007)


1. Given the condition below, slab element stiffness will be reduced by 100 (default value).
[Column not shown for clarity]

p97

Esteem Innovation, 2013

Below is an example of the effect of this change in specification between version 7.0.91.0 C to
7.0.77.0 C
Version 7.0.77.0 C compare to 7.0.91.0 C
Keyplan

p98

Esteem Innovation, 2013

Version 7.0.77.0 C compare to 7.0.91.0 C


Moment and
Shear
Diagram of
beam "gb3"

version 7.0.77.0 C

Conclusion

version 7.0.91.0 C
Version 7.0.91.0 C provides a more accurate mesh model to obtain the results.

2. Minimum link spacing. Should the link spacing requirement (due to torsion check) go
below the set value (100mm as in the example below), the program will overwrite this
constraint for the beam concerned.

p99

Esteem Innovation, 2013

3. Lean concrete text can be adjusted by using Label layer which share with bar detailing
text. The lean concrete text will use the Label layer which also share with bar detailing
test.

p100

Esteem Innovation, 2013

p101

Esteem Innovation, 2013

4. Support dimension in beam detailing can be turn off.

p102

Esteem Innovation, 2013

5.

Solving beam link design problem (beam that need more link loop will fail in intial
p103

Esteem Innovation, 2013

stage)

p104

Vous aimerez peut-être aussi