Vous êtes sur la page 1sur 18

2/19/2016

XTENDAccess/Flexi
Commissioning

ConfigurationGuide

PCRequirements

Windows 7,8,10
CPU

IntelCore2 Duo1.6GHz

RAM

1GB

HDD

40GBormorefreecapacity

Display

ColorLCD(1024x768)

LAN

10/100BaseT(X)

Software

IE7,IE7,Firefox3.6 orhigher

2/19/2016

PCNetworkSettings

ConnecttoLCTportofXTEND
IDU
ObtainanIPaddress
automatically
IPaddressofXTENDIDULCT
interface:172.17.254.253
3

Connectivitycheck
Ping172.17.253.254

2/19/2016

Login
Connectviawebbrowserto:172.17.254.253 (LCT
port)

Username:Admin
Password:12345678
5

Webinterface
Maintenance
User

Alarm
Summary

Remote
side

Logout

Refresh
Alarms
Tree
menu

Alarm
log

2/19/2016

Setdate/time

DisplayPC
Time

Important!!!

Date/Time
Setting

Setmanually
orDisplayPC
Time
7

Checklicenses
Description

Code

License
Information

License
Summary

2/19/2016

Updatelicenses
Deliveredas
.keyfiles
Connected
withunitSN

ImportLicense
Key

Browseforfile

EquipmentConfiguration
Terminalinitial
setup
Configurationof
thehardware
Redundancy
Aggregation

Equipment
Configuration

Setupbutton

10

2/19/2016

TerminalName

Equipment
Configuration

Set
Terminal
Name

11

Activatemodem
OnlyMODEM1for1+0

12

2/19/2016

Confirmconfig

Changes
highlighted

Review
configuration
andOK

13

RadioConfiguration

Setup

Setupradio
parameters:
Bandwidth
Modulation
Frequency
(TX/RX)
Radio
Configuration

14

2/19/2016

RadioSettings

XCVRlimits

Reference
Modulation
RadioMode

ChooseBW

TXFrequency
(RXautomatic)

15

ConfirmSettings
OKtoSave
configuration
changes
Changes
highlighted

16

2/19/2016

Frequencychannelsused
Band
7GHz
7GHz
7GHz
7GHz

Ch No
1
2
3
4

TX
7457.000
7485.000
7513.000
7541.000

RX
7625.000
7653.000
7681.000
7709.000

Bandwidth
28
28
28
28

Duplex
168.000
168.000
168.000
168.000

XTEND
A
A
B
B

8GHz
8GHz
8GHz

4
7
8

7836.650
7925.600
7955.250

8147.970
8236.920
8266.570

29.65
29.65
29.65

311.320
311.320
311.320

C
D
D

13GHz
13GHz
13GHz
13GHz
13GHz

2
4
5
7
8

12793.000
12849.000
12877.000
12933.000
12961.000

13059.000
13115.000
13143.000
13199.000
13227.000

28
28
28
28
28

266.000
266.000
266.000
266.000
266.000

A
B
C
D
D

15GHz
15GHz
15GHz
15GHz
15GHz

9
10
11
12
13

14641.000
14669.000
14697.000
14725.000
14753.000

15131.000
15159.000
15187.000
15215.000
15243.000

28
28
28
28
28

490.000
490.000
490.000
490.000
490.000

L
L
L
L
M

18513.250
18464.250
18492.250

19521.250
19472.250
19500.250

14
28
28

1008.000
1008.000
1008.000

D
D
D

18GHz
18GHz
18GHz

17

AMR/RadioMappingConfiguration
AMRSetting
E1enable
ChooseAMR
Steps

Setupfor
changes

AMR
RadioMapping

18

2/19/2016

AMREnable
Adaptive
Modulation
Rate

Enable/Disable

19

E1Activation
Activate
different
numberof
E1sforeach
modulation
rate.
Cannot
exceedthe
total
throughput

E1sreserved
fromtotal

Throughput
exceeded

20

10

2/19/2016

NetworkManagement
NetworkConfig

IPAddress
Netmask
Gateway
ConnectNMS
NMSportto
interface

21

Inband Management
ActivateInband
Management

SelectVLANfor
Inband

ActivateInband
SpecifyVLAN
Planfortrunk
oraccesstraffic
port!
AssignInband
toBridge01

22

11

2/19/2016

TXPower
SetTXpower
toMTPC
MAXvaluefor
alignment

MODEMto
modify

TXPower

23

Metering

HigherSpeed
Updates(3s)

TXPower
RXLevel
Voltage
BER
Current
Modulation
FanSpeeds

24

12

2/19/2016

XConnect

AddXConnect

XConnectE1s
definedinRadio
Mapping
Thecircuitswillbe
crossconnected
fromthePhysical
PortstotheRadio
Port
Symmetrical
settingsmustbe
doneonboth
sidesofthelink

XConnect
Setting

25

E1Connect

Service
(unique)

ServiceName

ToMODEM1
FromMain
Board

HighlightPort1
BothSides

Multiple
Selection
Possible
26

Available
PhysicalPorts

Configuredin
RadioMapping

13

2/19/2016

AMRLinkage
WhichE1
will
survive
whenlinkis
degraded?

Normally
10xE1

DegradedLink
Only1and2

27

XConnectSummary
Overview

LabelCanBe
Updated

XConnect
Delete

28

14

2/19/2016

PhysicalE1Ports
ModifySettings

Enable
Disable
Label
PortSetting

29

E1PortsSettings
Used
NotUsed
Usage
Report
Impedance
Label

Enable/Disable
All

ReportAll

ImpedanceAll

IndividualPort
Settings

30

15

2/19/2016

SyncMaster

MasterSide

Synchronismbetween
elementsismandatory.
Ifnotset,slipsandundesired
lossofsynchronizationwillbe
present.
AlarmsofUnlockedon
Modemswillbeshown
permanently.
Ifnoexternalclocksource
providedbythecustomer
thenonesideofthelinkwill
beprovidingclockinFreerun
(Master),andtheotherside
ofthelinkwillbeSlave,taking
ClockfromtheRadioside
(Modem).

ClockSetting

31

SyncSlave
Slaveside:
1.Provisioning/EquipmentClock/
SynchronizationSetting.
2.Modify.Select
Slave.
3.TimingSourceMODEM1,Port01,
Prioritylevel:1.
4.ClickOk.

SlaveSide

Select
MODEM1

32

16

2/19/2016

EthernetTrafficPorts
EnablePhysical
Ports
Max:
4xGbE
electrical
2xGbE Optical
ETHPort
Setting

PortEnable
33

DefineVLANIDs

AddVLANID
(14094)

CustomService
Name

AddVLANIDs
Couldbea
standardlistof
IDsforthe
network

VLANSetting

34

17

2/19/2016

DefinePortTypes
Access
Tunnel
Trunk

PortType

VLANSelection

35

18

Vous aimerez peut-être aussi