Académique Documents
Professionnel Documents
Culture Documents
XTENDAccess/Flexi
Commissioning
ConfigurationGuide
PCRequirements
Windows 7,8,10
CPU
IntelCore2 Duo1.6GHz
RAM
1GB
HDD
40GBormorefreecapacity
Display
ColorLCD(1024x768)
LAN
10/100BaseT(X)
Software
IE7,IE7,Firefox3.6 orhigher
2/19/2016
PCNetworkSettings
ConnecttoLCTportofXTEND
IDU
ObtainanIPaddress
automatically
IPaddressofXTENDIDULCT
interface:172.17.254.253
3
Connectivitycheck
Ping172.17.253.254
2/19/2016
Login
Connectviawebbrowserto:172.17.254.253 (LCT
port)
Username:Admin
Password:12345678
5
Webinterface
Maintenance
User
Alarm
Summary
Remote
side
Logout
Refresh
Alarms
Tree
menu
Alarm
log
2/19/2016
Setdate/time
DisplayPC
Time
Important!!!
Date/Time
Setting
Setmanually
orDisplayPC
Time
7
Checklicenses
Description
Code
License
Information
License
Summary
2/19/2016
Updatelicenses
Deliveredas
.keyfiles
Connected
withunitSN
ImportLicense
Key
Browseforfile
EquipmentConfiguration
Terminalinitial
setup
Configurationof
thehardware
Redundancy
Aggregation
Equipment
Configuration
Setupbutton
10
2/19/2016
TerminalName
Equipment
Configuration
Set
Terminal
Name
11
Activatemodem
OnlyMODEM1for1+0
12
2/19/2016
Confirmconfig
Changes
highlighted
Review
configuration
andOK
13
RadioConfiguration
Setup
Setupradio
parameters:
Bandwidth
Modulation
Frequency
(TX/RX)
Radio
Configuration
14
2/19/2016
RadioSettings
XCVRlimits
Reference
Modulation
RadioMode
ChooseBW
TXFrequency
(RXautomatic)
15
ConfirmSettings
OKtoSave
configuration
changes
Changes
highlighted
16
2/19/2016
Frequencychannelsused
Band
7GHz
7GHz
7GHz
7GHz
Ch No
1
2
3
4
TX
7457.000
7485.000
7513.000
7541.000
RX
7625.000
7653.000
7681.000
7709.000
Bandwidth
28
28
28
28
Duplex
168.000
168.000
168.000
168.000
XTEND
A
A
B
B
8GHz
8GHz
8GHz
4
7
8
7836.650
7925.600
7955.250
8147.970
8236.920
8266.570
29.65
29.65
29.65
311.320
311.320
311.320
C
D
D
13GHz
13GHz
13GHz
13GHz
13GHz
2
4
5
7
8
12793.000
12849.000
12877.000
12933.000
12961.000
13059.000
13115.000
13143.000
13199.000
13227.000
28
28
28
28
28
266.000
266.000
266.000
266.000
266.000
A
B
C
D
D
15GHz
15GHz
15GHz
15GHz
15GHz
9
10
11
12
13
14641.000
14669.000
14697.000
14725.000
14753.000
15131.000
15159.000
15187.000
15215.000
15243.000
28
28
28
28
28
490.000
490.000
490.000
490.000
490.000
L
L
L
L
M
18513.250
18464.250
18492.250
19521.250
19472.250
19500.250
14
28
28
1008.000
1008.000
1008.000
D
D
D
18GHz
18GHz
18GHz
17
AMR/RadioMappingConfiguration
AMRSetting
E1enable
ChooseAMR
Steps
Setupfor
changes
AMR
RadioMapping
18
2/19/2016
AMREnable
Adaptive
Modulation
Rate
Enable/Disable
19
E1Activation
Activate
different
numberof
E1sforeach
modulation
rate.
Cannot
exceedthe
total
throughput
E1sreserved
fromtotal
Throughput
exceeded
20
10
2/19/2016
NetworkManagement
NetworkConfig
IPAddress
Netmask
Gateway
ConnectNMS
NMSportto
interface
21
Inband Management
ActivateInband
Management
SelectVLANfor
Inband
ActivateInband
SpecifyVLAN
Planfortrunk
oraccesstraffic
port!
AssignInband
toBridge01
22
11
2/19/2016
TXPower
SetTXpower
toMTPC
MAXvaluefor
alignment
MODEMto
modify
TXPower
23
Metering
HigherSpeed
Updates(3s)
TXPower
RXLevel
Voltage
BER
Current
Modulation
FanSpeeds
24
12
2/19/2016
XConnect
AddXConnect
XConnectE1s
definedinRadio
Mapping
Thecircuitswillbe
crossconnected
fromthePhysical
PortstotheRadio
Port
Symmetrical
settingsmustbe
doneonboth
sidesofthelink
XConnect
Setting
25
E1Connect
Service
(unique)
ServiceName
ToMODEM1
FromMain
Board
HighlightPort1
BothSides
Multiple
Selection
Possible
26
Available
PhysicalPorts
Configuredin
RadioMapping
13
2/19/2016
AMRLinkage
WhichE1
will
survive
whenlinkis
degraded?
Normally
10xE1
DegradedLink
Only1and2
27
XConnectSummary
Overview
LabelCanBe
Updated
XConnect
Delete
28
14
2/19/2016
PhysicalE1Ports
ModifySettings
Enable
Disable
Label
PortSetting
29
E1PortsSettings
Used
NotUsed
Usage
Report
Impedance
Label
Enable/Disable
All
ReportAll
ImpedanceAll
IndividualPort
Settings
30
15
2/19/2016
SyncMaster
MasterSide
Synchronismbetween
elementsismandatory.
Ifnotset,slipsandundesired
lossofsynchronizationwillbe
present.
AlarmsofUnlockedon
Modemswillbeshown
permanently.
Ifnoexternalclocksource
providedbythecustomer
thenonesideofthelinkwill
beprovidingclockinFreerun
(Master),andtheotherside
ofthelinkwillbeSlave,taking
ClockfromtheRadioside
(Modem).
ClockSetting
31
SyncSlave
Slaveside:
1.Provisioning/EquipmentClock/
SynchronizationSetting.
2.Modify.Select
Slave.
3.TimingSourceMODEM1,Port01,
Prioritylevel:1.
4.ClickOk.
SlaveSide
Select
MODEM1
32
16
2/19/2016
EthernetTrafficPorts
EnablePhysical
Ports
Max:
4xGbE
electrical
2xGbE Optical
ETHPort
Setting
PortEnable
33
DefineVLANIDs
AddVLANID
(14094)
CustomService
Name
AddVLANIDs
Couldbea
standardlistof
IDsforthe
network
VLANSetting
34
17
2/19/2016
DefinePortTypes
Access
Tunnel
Trunk
PortType
VLANSelection
35
18