Vous êtes sur la page 1sur 1

GIT-H2

S.No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

Test Description
SW Reset-Verify of correct SW start up after reset
SSH-Verify Telnet is disabled in case of ALU. Only SSH is enabled
Uplink Description-Uplink Port descritpion should be there
No incremental CRC Errors on the link
No link should sync on half duplex
System date & time should be correct
No uplink alarms should be present
Alarm should come in case of Line card is removed
FAN/FAN Tray failure should come in case of FAN Tray removed
Alarm should come in case controller card is removed.
All unused Uplink Should be Shutdown
Idle session time out should be configured
TYPE
HSI VLAN
IPTV VLAN

16
17
18
19
20
21
22
23
24
25
26
27

Voice VLAN
Mgmt. VLAN ID
Mgmt. IP
Mgmt. Subnet Mask
Signaling VLAN ID
Signaling IP
Signaling Subnet
Signaling Gateway
Media VLAN ID
Media IP
Media Subnet
Media Gateway

28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47

ADSL & VDSL2 Vectoring Services Speed testing= PPPoE mode


ADSL & VDSL2 Vectoring Services Speed testing=Bridge mode
ADSL & VDSL2 Vectoring Services Speed testing=Static user
Rate Limit Testing= 2, 4, & 8 Mb
Rate Limit Testing=16Mb
Rate Limit Testing=32Mb
Rate Limit Testing=40Mb
Rate Limit Testing=Mb
IPTV Services Testing with Snooping Setting (SD TV & HD TV)
WIFI Hot Spot Service Testing
Port Binding test
Basic Voice Call testing=Local OG
Basic Voice Call testing= Local IG
Basic Voice Call testing=Centrex - OG & IC
Basic Voice Call testing=Reverse Centrex - OG & IC
Basic Voice Call testing=Intra MSAN to MSAN -IC & OG
Basic Voice Call testing=Intra MSAN to SIP/FTTH-IC & OG
Three Party Conference Call
Call Transfer
Call Waiting
External Alarm
External Alarms verfication-Type of Alarms=High Temperature
External Alarms verfication-Type of Alarms=PP Fail
External Alarms verfication-Type of Alarms=Low Battery
External Alarms verfication-Type of Alarms=AC Main Fails
External Alarms verfication-Type of Alarms=Fire
External Alarms verfication-Type of Alarms=Door Open
External Alarms verfication-Type of Alarms=DG fail to Start
Service Assurance
Controller Card Redundancy via Command Line
Controller Card Redundancy via Manual Cards Jackout -JackIn
Power Card Redundancy via Manual Cards Jackout -JackIn
Power Source Redundancy
Chassis Power Restoration time
Dual Uplink Redundancy Via Command Line
Dual Uplink Redundancy Via Manual Patch Cord Jackout -JackIn
Monitoring
Visibility of Node in EMS

48
49
50
51
52
53
54
55
56
57
58
59
60
61
62

Mohd Zaid
Huawei Representative Signature

Criteria
System should come up with MA5600V800R016C00 version
User should not able to do Telnet
Uplink Must persent as per CRF UPLINK
Value of CRC should be 0
Uplink should sync on Full Duplex
Time should be correct and need to be Record
Need to verify from EMS , and EMS should not show any alarm on Uplink port
Need to verify from EMS , and EMS should show alarm if Board Removed
Need to verify from EMS , and EMS should show alarm if Board Removed
Need to verify from EMS , and EMS should show alarm if Board Removed
Must be shoutdown
10 Min

AT Observation
ok
ok
ok
ok
ok
ok
ok
ok
ok
ok
ok
ok
Detail

Pass/Fail
pass
pass
pass
pass
pass
pass
pass
pass
pass
pass
pass
pass

1179

pass
pass

2018
33
3980

10.108.21.113

pass
pass
pass
pass
pass
pass
pass
pass
pass
pass
pass
pass

Subscriber should connect in PPPoe Mode


Subscriber should connect in Bridge Mode
Subscriber should work on Static IP
Subscriber should to get 2, 4 & 8 Mb
Subscriber should to get 16
Subscriber should to get 32
Subscriber should to get 40
Subscriber should to get 80
IPTV should run normal
Wifi Should work
Port Binding should work
outgoing should work
incoming should work
incoming should work & outgoing should work
Incoming should work & outgoing should work
Incoming should work & outgoing should work
Incoming should work & outgoing should work
Confrence should work
Call Transfer should work
Call waiting should work

ok
ok
ok
ok
ok
ok
ok
ok
ok
ok
ok
ok
ok
ok
ok
ok
ok
ok

pass
pass
pass
pass
pass
pass
pass
pass
pass
pass
pass
pass
pass
pass
pass
pass
pass
pass

simulated Alarm should be reported to EMS


simulated Alarm should be reported to EMS
simulated Alarm should be reported to EMS
simulated Alarm should be reported to EMS
simulated Alarm should be reported to EMS
simulated Alarm should be reported to EMS
simulated Alarm should be reported to EMS

ok
ok
ok
ok
ok
ok
ok

pass
pass
pass
pass
pass
pass
pass

Service should not impact; <= 2 RTO


Service should not impact; <= 2 RTO
Service should not impact; <= 2 RTO
Service should not impact; <= 2 RTO
Service should not impact; <= 2 RTO
Service should not impact; <= 2 RTO
Service should not impact; <= 2 RTO

ok
ok
ok
ok
ok
ok
ok
Status
ok

pass
pass
pass
pass
pass
pass
pass

10.226.166.243
as per CRF detail

255.255.255.248
33
10.107.21.115

255.255.255.248
10.107.21.113

32
10.108.21.115

255.255.255.248

Node Should be Visible in EMS

TNL Field Representative Signature

pass