Académique Documents
Professionnel Documents
Culture Documents
V4.1
Established in 2000, Zhuhai Pilot Technology Co., Ltd. occupies an area of 20,000 square meters
plant with nearly 400 staffs.
PILOT headquarter in Zhuhai of China, and equipped with a R&D center in Shenzhen Nanshan
Technology Park.
Our business is throughout the world with over 20 branch offices in China, and distribution
network in Germany, Romania, Iran, Saudi Arabia, UAE, Pakistan, India, Indonesia, Malaysia,
New Zealand, Australia, Canada, Mexico, Colombia, Chile, Brazil etc.
Our products and services:
--Digital panel meters
--Multifunction power meters
--Energy meters
--Power Quality Analyzer
--Branch circuit monitor
--LV motor protection and control devices
--Leakage current detectors
--Energy efficiency solution
Additional, our R&D team design customized products to satisfy your special requirements.
CONTENTS
Page
Certificate
Projects References
Products
PST700 Multifunction Power Meter
8
9
11
14
17
20
23
23
25
27
29
Certificate
Projects References
Projects Abroad
Hindustan Zinc Limited, the Lead Plant and Silver Plant ( India)
IKEA Mega Bangna - IKEA Asias Largest Complex (Thailand)
Trekkpje Uranium Plant (South Africa)
D.G Khan Cement Plant (Pakistan)
Bandung Hydropower Plant (Indonesia)
Scotts Feeds Factory Project ( U.K.)
Iranian Petrochemical Project ( Iran)
Olympic Venues
Beijing Olympic Hockey Center
Beijing Olympic Beach Volleyball Center
Beijing Olympic Shooting Range
Qingdao International Sailing Center
Beijing Olympic Basketball Gymnasium
Municipal Projects
Shanghai F1 International Circuit
Shanghai Pudong Government Processing Center
Shanghai World Expo - World Expo Axis
Shanghai World Expo Village, Block B/ Block D/E plot
Shanghai World Expo-China Pavilion
Bank of China Shanghai Information Center
Chengdu Commodity Inspection Bureau
Guangzhou Baiyun International Convention and Exhibition Centre, Phase I, II, III
Guangzhou International Financial Center (also known as Guangzhou West Tower)
Handan Wastewater Treatment Plant
Hangzhou Nanxing Water Plant
Industrial and Commercial Bank of China Head Office Building, Xinjiang
Nanjing Jiuhuashan Tunnel
New Museum of Nanjing Massacre Memorial Hall
Sichuan Cangxi Wastewater Treatment Plant
Sichuan Wenjiang Water Plant
Urumqi Inspection Centre
Xingjiang Radio and Television Building
Xinjiang Television Station Building
Airports / Metro
Guangzhou New Baiyun International Airport
Shanghai Pudong International Airport, Phase II
Shanghai Hongqiao Airport Reconstruction Project
Qingdao Luiting International Airport
Wuxi Airport
Urumqi Airport Overnight Floor
Xinjiang Kanas Airport Terminal
Beijing Metro Line 4#, 5#
Shanghai Metro Line 6#, 7#
Dalian Light Rail Line 3#
Shenzhen Metro Line 1#
Guangzhou Metro Line 2#/ 3#, 4#
Projects References
Telecommunication Porjects
Shenzhen King Tin Telecommunications Room
Shenzhen Fu Yong Telecommunications Room, Phase I,II,& III
China Netcom Building in Shanghai
China Mobile Building in Henan
China Mobile Building in Wangjing
China Unicom Building in Zhuhai
Tobacco Industry
Hongyun Group, Kunming Cigarette Factory Moving Project
Longyan Cigarette Factory
Guiyang Cigarette Factory
Hongta Group, Yuxi Cigarette Factory
Hongyun Group, Honghe Cigarette Factory
Shijiazhuang Cigarette Factory
PMAC615
PMAC625
PMAC720
PMAC735
PMAC727
PMAC760
PMAC901
PMAC903
PMAC905
PMAC915
PMAC921
Display
LCD
LED
LED
LCD
LCD
LCD
LCD
LCD
LCD
LCD
LCD
LCD
Single or 3 phase
single
single
single
U, I, P, Q, kWh
PF, F
kvarh
kVAh
Demand
Multi-tariff energy
Model
Features
Photo
Real-time measurement
Phase angle
Temperature
Power quality analysis
Harmonic
Current K factor
Unbalance rate
Load rate
U or F deviation
DI/ DO
Status input
Relay output
Analog input
Analog output
Pulse output
Communication
RS485 / Modbus
Profibus
Ethernet or USB
Infrared COM
Memory card
Other functions
SOE event log
Setpoint alarm
Data record
standard feature
optional feature
Real-time measurement
True-RMS measuring parameters includes:
U, I, P, Q, S, PF, F, kWh, kvarh, kVAh, demand, max./min. value
Basic unit
Holiday mode: working days ( Mon.- Fri.) and holidays ( Sat.- Sun.)
Optional module
There are 2 lists of tariff rate, each list can setup 8 periods of time in 24 hours, 4
tariff rates.
Setpoint alarm
Under/ over limit alarm, monitoring objects include: U, I, PF, F, THD, unbalance
If any parameters is over or under limit and persists over the specified time,
PST700 will record the event, and trip relay output signal.
High accuracy
Active energy: according to IEC62053-22, class 0.5s
Reactive energy: according to IEC62053-23, class 2
Cut-out: 90x90mm,
Standard
Voltage
Ua, Ub, Uc, Uab, Ubc, Uca, UL-L avg, UL-N avg
Current
Power
Power factor
Energy
Frequency
Multi-tariff energy
Unbalance
U_unbl, I_unbl
Harmonic (31st )
3DI +2 DO
RS485
Modbus-RTU protocol
SOE (event log), Real-time clock ( yyyy-mm-dd hh:mm:ss)
Record function
Voltage/ frequency deviation, Voltage unbalance record
Optional Module
S
2 status input
Profibus communication
2 relay output
AI
The 2 RS485
AO
Ep
2 pulse output
BA
BACnet protocol
nd
Parameter
Accuracy
Resolution
1GB memory
Measuring Range
Direct: 600Vph-ph
Voltage
0.2%
0.01V
Current
0.2%
0.001A
Power
0.5%
0.1W/var/ VA
PT primary: 0~999.9kV
PT secondary: 100Vph-ph or 110V
CT primary: 0~49,999A
CT secondary: 1 A or 5A
each phase: 0~49994MW/ Mvar/ MVA
Total: 0~149982MW/ Mvar/ MVA
Power factor
0.5%
0.001
-1.000~+1.000
Frequency
0.01
0.01Hz
45~ 65 Hz
Active energy
0.5%
0.1kWh
0~ 99,999,999.9 kWh
Reactive energy
2.0%
0.1kvarh
0~ 99,999,999.9 kvarh
THD
1.0%
0.001
0~100.0%
Individual harmonic
1.0%
0.001
0~100.0%
Un-balance
1.0%
0.001
0~100.0%
Power supply
86 ~265VAC99~374VDC
Input
Rate current: 1A or 5A
Rate voltage: direct 120 ~277Vph-N, (optional)
PT secondary: 100Vph-ph or 110V, (optional)
Frequency: 50/ 60Hz
Power loss
2VA
Communication
Dimension
(L x W x H)
Panel: 96 x 96 x 13.5 mm
Cut-out: 90 x 90 x 45.1 mm (basic)
90 x 90 x 66.6 mm (optional module)
Overload
Status input
Relay output
IP index
Pulse output
Weight
Environment
AC 2KV/minute
Insulation resistance
50M
IEC 61000-4-5,Level 3
EN 55022,Class B
EN 55022,Class B
Order Information
Basic unit: PST700
Note: 1: Current input 5A (optional 1A)
2: Voltage input: 0~600V.
3. Default PT secondary 100Vph-ph. (optional 110V)
Optional module
S
R
C
Ep
2 status input,
2 relay output
The 2nd RS485
2 pulse output
P
AI
AO
BA
M
CT ratio programmable
Standard: IEC62053-21, CE
Basic Function
Real time
metering
Optional Function
Parameter
Accuracy
Resolution
Measuring Range
DI
Voltage
0.2%
0.01V
0 ~ 500Vph-ph
DO
Current
0.2%
0.001A
0 ~ 50,000A
Power
0.5%
0 ~30MW/ Var
Power factor
0.5%
0.001
-1.000 ~ +1.000
Frequency
0.01
0.01Hz
45 ~ 65Hz
Active energy
1.0%
0.1kWh
0-99,999,999.9 kWh
COM
One RS485
Technical Specification
Metering
AC 2KV/minute
Input
Insulation resistance
50M
4kV (peak),
1.2/50uS
Overload
Dimension
(L x W x H)
Panel: 110 x 65 x 18 mm
Cut-out: 90 x 44.5 x 55 mm (+0.5mm)
Status input
IP index
Relay output
1 channel,
Node capacity: 220VAC/5A, 30VDC/5A
Weight
Approx 220gr.
Power supply
85~265VAC, 80~300VDC
Environment
Power loss
3VA
Communication
IEC 61000-4-5,Level 3
EN 55022,Class B
EN 55022,Class B
Order Information
PMAC615----
W
Voltage + Current + Active Power + Reactive Power + Power Factor + Frequency + Active Energy
S
RC
C
CT primary is programmable
Password protect
Standard: IEC62053-21, CE
Basic Function
Optional Function
Frequency--F
Active energykWh
Technical Specification
Metering
AC 2KV/minute
Input
Insulation resistance
50M
4kV (peak),
1.2/50uS
Overload
Dimension
(L x W x H)
Panel: 96 x 96 x 18 mm
Cut-out: 89.5 x 89.5 x 65 mm (+0.5mm)
Status input
IP index
Relay output
2 channels,
Node capacity: 220VAC/5A, 30VDC/5A
Weight
Approx. 350gr.
Environment
Power supply
85~265VAC, 80~300VDC
Power loss
2VA
Communication
IEC 61000-4-2,Level 4
IEC 61000-4-3,Level 3
IEC 61000-4-4,Level 4
IEC 61000-4-5,Level 3
EN 55022,Class B
EN 55022,Class B
Accuracy
Resolution
Measuring Range
Voltage
0.2%
0.01V
Current
0.2%
0.001
CT primary: 0~9,999A
CT secondary: 1 A or 5A
Power
0.5%
0.1W/ var
Power factor
0.5%
0.001
-1.000~+1.000
Frequency
0.01
0.01Hz
35-65Hz
Active energy
1.0%
0.1kWh
0-99,999,999.9 kWh
Reactive energy
2.0%
0.1kvarh
0-99,999,999.9 kvarh
Order Information
PMAC625---
W
Voltage + Current + Active Power + Reactive Power + Power Factor + Active Energy
Voltage + Current + Active Power + Reactive Power + Power Factor + Frequency + Active Energy
+ Reactive Energy
S
R
C
Note: PMAC625 default rated voltage/ current is 220V/ 5A. Other customized input such as 240V or 1A is available, please mention the
requirement before place order.
Example: Model No. PMAC625-W-C, which indicates the device measures voltage, current, active power, reactive power, power factor,
active energy, and provide RS485 communication
10
CT and PT programmable
Password protect
Basic Function
PMAC720 provides one RS485 communication,
measures and display real-time parameters:
Frequency--F
Active energykWh
Optional Function
TOU (multi-tariff)
Basic unit
Optional module
Optional Module
Technical Specification
Metering
Power supply
85~265VAC, 80~300VDC
Input
Power loss
2VA
Communication
Dimension
(L x W x H)
Panel: 96 x 96 x 16 mm
Cut-out: 89.5 x 89.5 x 55 mm (+0.5mm)
IP index
Weight
Approx. 500gr.
Overload
Status input
(optional)
8 channels,
provides 30VDC power if it is dry contact
Relay output
(optional)
4 channels,
Node capacity: 220VAC/5A, 30VDC/5A
Analog output
(optional)
2 channels,
4~20mA, load resistance: 400
Pulse output
(optional)
2 channels,
48~50VDC for external connection
AC 2KV/minute
Insulation resistance
50M
4kV (peak),
1.2/50uS
11
Environment
Parameter
Accuracy
Resolution
Voltage
0.2%
0.01V
Current
0.2%
0.001A
Power
0.5%
0.1W/ var
Measuring Range
Directly: 300Vph-N, 520Vph-ph
PT primary: 0~599,999V
PT secondary: 57.7Vph-N, 100Vph-ph
CT primary: 0~49,999A
CT secondary: 1 A or 5A
each phase: 0~100 MW/ Mvar
Total: 0~300 MW/ Mvar
Power factor
0.5%
0.001
-1.000~+1.000
Frequency
0.01
0.01Hz
45~ 65 Hz
Active energy
1.0%
0.1kWh
0~ 99,999,999.9 kWh
Reactive energy
2.0%
0.1kvarh
0~ 99,999,999.9 kVarh
Individual harmonic
1.0%
0.001
0~100.0%
Un-balance
1.0%
0.001
0~100.0%
PMAC-
720N
720A
720B
720C
720D
720E
Feature
U-LL, U-LN, 3I, In, 3P, P, 3Q, Q,
F, 3PF, PF, kWh, kvarh,
RS485 communication
TOU ( time-of-use)
AI
AO
Apparent power
Demand function
12
Order Information
PMAC720---- ----
N
A
B
C
D
E
Basic Module
Basic Module + 4 Status Inputs (Dry Contact) + 4 Relay Outputs
Basic Module + 8 Status Inputs (Dry Contact) + 2 Relay Outputs
Basic Module + 4 Status Inputs (Wet Contact) + 4 Relay Outputs
Basic Module + 8 Status Inputs (Wet Contact) + 2 Relay Outputs
Basic Module + 2 Pulse Outputs + 2 Analog Outputs (4-20mA)
H
T
F
M
AI
AO
V1
V2
V3
V4
V5
V6
V7
Example: Model No. PMAC720-A-H-AO-V1, which indicates the device provides basic function + 4 status input + 4 relay
output + harmonic analysis + one analog output, rated input 57.7/ 100V, 5A
13
CT and PT programmable
Password protect
Basic Function
Record the Avg/ Max./ Min. data of every day (last 31 days)
Frequency--F
Active energykWh
Technical Specification
Metering
Power supply
85~265VAC, 80~300VDC
Input
Rate current: 1A or 5A
Rate voltage: direct 120 ~277Vph-N, (optional)
PT secondary 57.7V/ 100V
Frequency: 50/ 60Hz
Power loss
2VA
Communication
Dimension
(L x W x H)
Panel: 96 x 96 x 18 mm
Cut-out: 89.5 x 89.5 x 65 mm (+0.5mm)
IP index
Weight
Approx. 500gr.
Environment
Overload
AC 2KV/minute
Insulation resistance
50M
Standard (EMC)
Electrostatic discharge immunity test
IEC 61000-4-2,Level 4
Radiated immunity test
IEC 61000-4-3,Level 3
Electrical fast transient/burst immunity test IEC 61000-4-4,Level 4
IEC 61000-4-5,Level 3
EN 55022,Class B
EN 55022,Class B
14
Accuracy
Resolution
Measuring Range
Directly: 300Vph-N, 520Vph-ph
Voltage
0.2%
0.01V
Current
0.2%
0.001A
CT primary: 0~49,999A
CT secondary: 1 A or 5A
Power
0.5%
0.1W/ var
Power factor
0.5%
0.001
-1.000~+1.000
Frequency
0.01
0.01Hz
35~ 65 Hz
Active energy
1.0%
0.1kWh
0~ 99,999,999.9 kWh
Reactive energy
2.0%
0.1kvarh
0~ 99,999,999.9 kVarh
THD
1.0%
0.001
0~100.0%
Individual harmonic
1.0%
0.001
0~100.0%
Un-balance
1.0%
0.001
0~100.0%
Temperature
0~150
PT primary: 0~499,999V
PT secondary: 57.7Vph-N, 100Vph-ph
Model PMAC727
Over-limit record
I unbal
Load rate
Frequency
Measuring Parameters
15
Order Information
PMAC727--
V1
V2
V3
V4
V5
V6
V7
Example: Model No. PMAC727-V1, which indicates the device provides all basic function, rated input 57.7/ 100V, 5A
16
CT and PT programmable
Password protect
Standard: IEC62053-21/23, CE
Basic Function
Optional Module
Relay output apply to monitoring over limit alarm with setpoint system
Pulse output apply to exporting pulse signal for active/ reactive energy
Frequency--F
Optional Function
Technical Specification
Metering
AC 2KV/minute
Input
Rate current: 1A or 5A
Rate voltage: direct 120 ~277Vph-N, (optional)
PT secondary 57.7/ 100V
Frequency: 50/ 60Hz
Insulation resistance
50M
4kV (peak),
1.2/50uS
Power supply
85~265VAC, 80~300VDC
Power loss
2VA
Status input
(optional)
8 channels,
provides 30VDC power if it is dry contact
Communication
Relay output
(optional)
4 channels,
Node capacity: 220VAC/5A, 30VDC/5A
Analog
output
(optional)
1 channel,
4~20mA, load resistance: 400
Dimension
(L x W x H)
Panel: 96 x 96 x 18 mm
Cut-out: 89.5 x 89.5 x 65 mm (+0.5mm)
IP index
Pulse output
(optional)
2 channels,
48~50VDC for external connection
Weight
Approx. 500gr.
Overload
17
Standard (EMC)
Environment
Parameter
IEC 61000-4-2,Level 4
IEC 61000-4-3,Level 3
IEC 61000-4-4,Level 4
IEC 61000-4-5,Level 3
EN 55022,Class B
EN 55022,Class B
Accuracy
Resolution
Measuring Range
Directly: 300Vph-N, 520Vph-ph
Voltage
0.2%
PT primary: 0~499,999V
PT secondary: 57.7Vph-N, 100Vph-ph
0.01V
0.2%
0.001A
CT primary: 0~49,999A
CT secondary: 1 A or 5A
Power
0.5%
0.1W/ var
Power factor
0.5%
0.001
-1.000~+1.000
Frequency
0.01
0.01Hz
35~ 65 Hz
Active energy
1.0%
0.1kWh
0~ 99,999,999.9 kWh
Reactive energy
2.0%
0.1kvarh
0~ 99,999,999.9 kVarh
THD
1.0%
0.001
0~100.0%
Individual harmonic
1.0%
0.001
0~100.0%
Un-balance
1.0%
0.001
0~100.0%
Model PMAC
735N
735A
735B
735E
735P
Feature
U-LL, U-LN, 3I, In, 3P, P, 3Q, Q, 3S, S, F,
3PF, PF, kWh, kvarh,
Demand& maximum recording,
Unbalance rate,
Build-in clock,
Max./min. recording,
RS485 communication
Profibus communication
Harmonic analysis, K factor
SOE
One 4-20mA analog output
18
PMAC735
Auxiliary
Module
Order Information
PMAC735---- ------
N
A
B
E
P
Basic Module
Basic Module + 4 Status Inputs (Dry Contact) + 4 Relay Outputs
Basic Module + 8 Status Inputs (Dry Contact) + 2 Relay Outputs
Basic Module + 8 Status Inputs (Dry Contact) + 2 Pulse Outputs
Basic Module + Profibus Module
AO
V1
V2
V3
V4
V5
V6
V7
Example: Model No. PMAC735-A-H-V1, which indicates the device provides basic function + 4 status input + 4 relay output +
harmonic analysis, rated input 57.7/ 100V, 5A
19
Password protect
Basic Function
Voltage
Ua, Ub, Uc, Uab, Ubc, Uca, UL-L avg, UL-N avg
Current
Power
Power factor
Energy
Demand
Phase angle
Frequency
Voltage fluctuate
Voltage deviation
Power quality analysis
Frequency deviation
Unbalance
U_unbl, I_unbl
Harmonic
Setpoint alarm
DI/ DO
RS485
Modbus-RTU protocol
Optional Function
Ethernet
USB
20
Harmonic
Phase vector
Multi-communication
Technical Specification
Metering
AC 2KV/minute
Input
Rate current: 1A or 5A
Rate voltage: direct 120 ~277Vph-N, (optional)
PT secondary 57.7/ 100V
Frequency: 50/ 60Hz
Insulation resistance
50M
4kV (peak),
1.2/50uS
Power supply
85~265VAC, 80~300VDC
Power loss
10VA
Dimension
(L x W x H)
IP index
Weight
Approx. 760gr.
Overload
Status input
4 channels
Dry contact (internal 30VDC power supply)
Relay output
4 channels,
Node capacity: 250VAC/5A, 30VDC/5A
Standard (EMC)
Electrostatic discharge immunity test
Radiated immunity test
Electrical fast transient/burst immunity test
Surge immunity test (1, 2/50s8/20s)
Conducted emissions
Radiated emissions
Environment
IEC 61000-4-2,Level 4
IEC 61000-4-3,Level 3
IEC 61000-4-4,Level 4
IEC 61000-4-5,Level 3
EN 55022,Class B
EN 55022,Class B
21
Accuracy
Resolution
Measuring Range
Voltage
0.2%
0.01V
Current
0.2%
0.001A
CT primary: 0~49,999A
CT secondary: 1 A or 5A
Power
0.5%
0.1W/ var
Power factor
0.5%
0.001
-1.000~+1.000
Frequency
0.01
0.01Hz
45~ 65 Hz
Active energy
1.0%
0.1kWh
0~ 99,999,999.9 kWh
Reactive energy
2.0%
0.1kvarh
0~ 99,999,999.9 kVarh
THD
1.0%
0.001
0~100.0%
Individual harmonic
1.0%
0.001
0~100.0%
Un-balance
1.0%
0.001
0~100.0%
COM
SHLD
SHLD
Order Information
PMAC760----
Ethernet port
USB port
V1
V2
V3
V4
V5
V6
V7
Example: Model No. PMAC760-N-V3, which indicates the device provides basic function + Ethernet communication port, rated
input 220/ 380V, 5A
22
Feature
Basic Function
Support Modbus-RTU
Optional Function
Multi-tariff
Demand analysis
Technical Specification
Rated current
Rated voltage
Input
consumption
2VA
Overload
115% of rated
Pulse output
1 or 2 channels
PMAC901:1000imp/kWh
PMAC903: 400imp/ kWh (40A or 60A)
200imp/ kWh (100A)
3600imp/ kWh (5A/ CT)
Connection mode
Impulse duration
80 ms
Power supply
Communication
Environment
Standard (EMC)
Electrostatic discharge immunity test
Radiated immunity test
Electrical fast transient/burst immunity test
IEC 61000-4-2,Level 4
IEC 61000-4-3,Level 3
IEC 61000-4-4,Level 4
IEC 61000-4-5,Level 4
EN 55022,Class B
EN 55022,Class B
Accuracy
Display
data
Communication data
Parameter
Resolution
Measuring Range
0.2%
0.01V
198V~242V (L-N)
0.2%
0.2%
0.001A
0.5~4995A
Active power
0.5%
0.5%
0.1W
0~1MW
Reactive power
No
1.0%
0.1Var
0~1Mvar
Apparent power
0.5%
0.5%
0.1VA
0~1MvA
Power factor
No
0.5%
0.001
-1.000~+1.000
Frequency
No
0.01
0.01Hz
45Hz~65Hz
Active energy
Class 0.5S
Class 0.5S
0.1kWh
0~999999.9 kWh
Reactive energy
No
Class 2
0.1kVarh
0~999999.9 kvarh
PMAC901
PMAC903
Voltage
0.2%
Current
23
Dimension
PMAC901
PMAC903
65.0mm
125.5mm
65.0mm
50.0mm
PMAC903
45.0mm
94.0mm
45.0mm
35.7mm
94.0mm
50.0mm
35.7mm
75.0mm
Order Information
PMAC901---- ----
PMAC903---- ----
C
1
0.5S
40
60
100
5
F
Q
D
TOU (Multi-tariff)
Reactive energy measuring (only available for PMAC903)
Demand analysis (only available for PMAC903)
Note: PMAC901, 903 default rated voltage 220V, frequency 50Hz. Other customized input such as120V or 60Hz is available, please
mention the requirement before place order.
Example 1: Model No. PMAC901-C-1-40-F, which indicates the device provides basic function, rated current is 40A (direct), accuracy class 1,
and measure multi-tariff
Example 2: Model No. PMAC903-C-1-5-Q, which indicates the device provides basic function, rated current is 5A/ CT, accuracy class 1, and
measure reactive energy
24
CT and PT programmable
Password protect
Basic Function
Optional Function
Record historical energy value: (kWh & kvarh) data of last 31 days/ 12
months
Frequency--F
Technical Specification
Connection mode
Pulse output
2 channels
Rated current
1A or 5A
Rated voltage
50ms
Power supply
Frequency
50/ 60Hz
Communication
CT earth connection
(secondary)
yes
Power consumption
3VA
Environment
Overload
120% of rated
Standard (EMC)
Electrostatic discharge immunity test
Radiated immunity test
Electrical fast transient/burst immunity test
Parameter
Accuracy
IEC 61000-4-2,Level 4
IEC 61000-4-3,Level 3
IEC 61000-4-4,Level 4
Resolution
IEC 61000-4-5,Level 4
EN 55022,Class B
EN 55022,Class B
Measuring Range
Directly: 300Vph-N, 520Vph-ph
Voltage
0.2%
0.01V
Current
0.2%
0.001A
CT primary: 0~49,999A
CT secondary: 1 A or 5A
Power
0.5%
0.1W/ Var/ VA
Power factor
0.5%
0.001
-1.000~+1.000
Frequency
0.01
0.01Hz
35Hz~65Hz
Active energy
Class 0.5S
0.1kWh
0~999999.9 kWh
Reactive energy
Class 2
0.1kVarh
0~999999.9 kvarh
PT primary: 0~499,999V
PT secondary: 57.7Vph-N, 100Vph-ph
25
96mm
9.0
46.7
18.3
90mm
96mm
56.5
89.5
90mm
Order Information
PMAC905---- ----
F
V1
V2
V3
V4
V5
V6
V7
Note: Other customized input such as 110V or 1A is available, please mention the requirement before place order.
Example: Model No. PMAC905-F-D-V3 , which indicates the device provides basic function, auxiliary statistics and record function.
Rated input is 220V/380V, 5A.
26
LCD display
With the DSP technology and the real-time high speed calculation, it guarantees the
measuring accuracy in the case of big load wave and harmonic waves.
Three phase power source supply, but even there is only one phase work, the meter
will keep running.
Read the meter at power failure, can still read the meter by the button or with
infrared function
Function
Energy measurement: measure kWh or kvarh (reverse/ forward) of 4 quadrants in different tariffs
Max. demand measurement: measure Max. demand kWh or kvarh (reverse/ forward) of 4 quadrants in different tariffs
Real-time measurement: measure voltage, current, active power, reactive power, power factor, frequency, 2nd -31st harmonic (U and I)
Multi-tariff: settable 10 tariffs, 14 time zones, 12 sets of time period list, 14 time periods, 13 holidays, holiday and weekend can be
preset in different time periods.
No-voltage record: record no-voltage of each phase and total no-voltage time of four months, record no-voltage occurs time, end time
and the energy in the time of no-voltage of the last 10 times.
Event log: record last 10 demand resetting, program, no phase, over-voltage, no voltage, unti-phase, overload, current unbalance,
calibrate time, power off and power on.
Load monitor: set voice-optical alarm or relay output when load is beyond a certain value
Harmonic monitor: monitor the 2nd 16th harmonic (U and I), when the value is beyond the setting point, the meter alarm and record the
event.
Energy freeze: freeze the energy by broadcast, also can freeze the energy at hour
Load curve: select different data groups with different or same time terminal (1 to 1440 mins optional) to record the data scrolling with
time remark. Storage space is not less than 2MKb.
Pulse output and LED indicator: two pulse output for active and reactive energy.
Technical Specification
Model
Accuracy
PMAC915
Active energy
Class 0.5s
Reactive energy
Class 2
Display
LCD
Rated voltage
PT connect:
357.7/100V
Direct connect
3220/380V
CT connect
31(2)A, 35(6)A
Direct connect
Voltage circuit
Current circuit
<1VA
Power loss
Operating temperature
-20C to +60C
Storage
-40C to +70C
27
85%
Voltage range
0.7Un ~1.3Un
Reference frequency
50Hz 5%
Start current
0.001 In
MTBF
5104 h
Service life
15 Years
Clock error
0.5s /d (23C)
Dimension
Net weight
Approx. 1.8 kg
Standard
IEC62052-11/21
IEC62053-21/22/23
IEC62056-21/ 42/ 53/ 61/ 62
28
LCD display
LSI design, less spare part, low power consumption, simple structure.
Use quality component with long service life, reliable accuracy, cannot be affected by
the frequency, temperature, voltage, harmonic.
Function
Measure reverse and forward energy, and reverse energy is measured as forward energy
Timely single phase power consumption measurement with 3 tariffs and 12 time periods
Automatically read and store the energy, it can store 12 months data
Waking up the meter by pressing the key and meter reading function during power off.
Technical Specification
Model
PMAC921
Relative humidity
85%
Accuracy
Voltage range
0.7Un ~1.3Un
Display
LCD
Reference frequency
50Hz/ 60Hz
Rated voltage
220~240V
Start current
0.004Ib
Clock error
0.5s /d (23C)
Dimension
Power
loss
Voltage circuit
<1W/ 6VA
Net weight
Approx. 700g
Current circuit
<1VA
Standard
IEC62052-11/21
IEC62053-21/22/23
IEC62056-21
Operating temperature
-25C to +55C
Storage
-40C to +70C
29
Your representative
Add: No. 15, Keji 6 Road, Chuangxin Haian, Tangjia Hi-tech Zone,
Zhuhai, Guangdong, China
Post Code: 519085
Tel: +86 756 3629687/ 3629673
Fax: +86 756 3629600/ 3629700
Email: overseamarket@pmac.com.cn
http://www.pmac.com.cn
PILOT reserves the right to modify features without prior notice in view of continued improvement