Vous êtes sur la page 1sur 3

Hazen-Williams Equation for Pressure Loss in Pipes

SI Units
Specified Data
l = length of pipe (m)
c = Hazen-Williams roughness constant
q = volume flow (liter/sec)
dh = inside or hydraulic diameter (mm)
Calculated Pressure Loss
f = friction head loss in mm of water per 100 m of pipe (mm H20 per 100 m pipe)
f = friction head loss in kPa per 100 m of pipe (kPa per 100 m pipe)
Head loss (mm H20)
Head loss (kPa)
Calculated Flow Velocity
v = flow velocity (m/s)

1049
140
1350
600

2432.26
23.86
25514.44 25.51444
250.30

4.77

Pipe Diameter Velocity Head loss Static Head Total Head


1000
1.72
2.13
7
9.13
900
2.12
3.55
7
10.55
800
2.69
6.29
7
13.29
700
3.51
12.05
7
19.05
600
4.77
25.51
7
32.51

Required Pump HP
162.00
187.26
236.00
338.22
577.22

Vous aimerez peut-être aussi