Network Installation
and Configuration
for CNC with Windows 2000
and CNC with Windows NT
REVISIONS
Rev.# Rev. Date.
Page Revised
00
------01
Dec. 01
Emission
CMAIR401120E
-------------- ----------------------------------------------------------------------------------------------------------Jan. 04 Second Edition
CMAIR404011E
------02
Complete revision
-------------- ----------------------------------------------------------------------------------------------------------Nov. 2004 Third Edition
CMAIR404122E
-------
Update the Manual with the Network Installation Instructions for CNC with
Windows 2000.
-------------- -----------------------------------------------------------------------------------------------------------
REVISIONS (cont.)
Rev.# Rev. Date.
Page Revised
INTRODUCTION
This Documentation is addressed to qualified technical personnel who have experience with Selca
S4000 series numeric controls and Windows based operating systems.
The objective is to ensure the connection and configuration of S4000 NC on Microsoft networks (typically
WINDOWS NT, WINDOWS XP, WINDOWS 2000, WINDOWS 9x or Unix systems configured as
Microsoft network servers).
The Microsoft network connection option for S4000 series system is called SELNETWIN4000.
Only the numeric controls for which this option has been purchased can be used for network
configuration and connection.
The procedures herein described are independent from the NC software version used and only employ
dialogues and menus of the operative system which
The Numerical Controls S4000, Export Version E excluded, are subject to export controls according to Appendix I of the
EU-Dual Use regulation.
INDEX
5. TROUBLESHOOTING........................................................................................5-1
FUNCTIONAL CONNECTION TESTS....................................................................... 5-1
Example of correct connection ................................................................................... 5-1
Example of incorrect connection ................................................................................ 5-2
1.1 CONNECTIONS
The currently used CAD/CAM milling system generates increasingly large files. This can cause
problems when transferring the files from one system to another if a communications network is not
available. For this reason, many users are asking to connect their machines to an Ethernet network.
Very often they realize this need only after purchasing the machine tool.
All S4000 systems are equipped with an integrated fast Ethernet network board which supports 10Mb/s
and 100Mb/s connections.
The SELNETWIN4000 option is necessary to connect the CNC to a network.
WARNING! If the optional module is not installed, the CNC can be configured to access the network
but will be disconnected when the CNC logs off. The configuration will be reset each time.
Connection to the network must be made using a double twisted shielded wire, (preferable S-FTP
shielded foiled twisted pair) class 5, minimum conductors 24AWG and RJ-45 connectors (8 wires 4 pairs) shielded.
The connection to the NC network board is made by inserting the connector in the system RJ-45
socket on the lower side of the metal cover on the back of the NC video unit.
The maximum length of the NC wire to the concentrator (HUB) must not exceed 100 m.
For correct operation, arrange the wire as far as possible from sources of electromagnetic noise (at
least 30 cm). Use network components providing adequate immunity. The NC and the other
network devices must be connected to an equipotential earth circuit to avoid the passage of
undesired currents through the wire shielding. Data transmission may be slowed down and even
blocked in extreme cases in the absence of this precautions.
The manufacturer will arrange the machine to be connected to the user's network or provide for laying
the wires at a later time.
1-1
CON-RETE:
SUPPCONRETE:
RETE.
CV-PRORETE: SFTP cable, one metre long, with male connectors for
connecting operator panel and control panel socket.
1-2
CONTROL PANEL
S4000
CV-PRORETE
CON-RETE
SUPPCONRETE
ELECTRICAL CABINET
SUPPCONRETE
CV-RETE
CON-RETE
RETE DEL
CLIENTE
1-3
Pin
1
1-4
Name Description
CV-RETE
Cable color
T568B Standard
cable color
TX+
White-Orange
TX-
Orange
RX+
Receive Data +
Yellow
White-Green
n/c
Not connected
Blue
Blue
n/c
Not connected
Red
White-Blue
RX-
Receive Data -
Green
Green
n/c
Not connected
White
White-Brown
n/c
Not connected
Brown
Brown
CONNECTION TYPE
Regardless of the type of wire used, the wiring section inside the machine must be pin-to-pin, i.e. the
connectors on both ends of the wire must follow the same arrangement of the wires. See figure below.
There are two possible cases:
The CNC connected to a pre-existing network hub: in this case, the CNC wire from the hub
must not be crossed, i.e. the wire arrangement must be respected on both ends, possibly following
the standard color arrangement (see table above - T568B wire).
Description.
TX+
TX-
RX+
Not used
Not used
RX-
Not used
Not used
1-5
1-6
The KILLALL.BAT program will be started. Repeat the operation for at least three times in a row. This
program will kill all CNC software modules. It must be started several times because the various
modules have different time sequences which must be followed in order to be correctly shut down.
2-1
Check whether certain system "services" (following the next instruction) have been started:
Click the following in sequence:
Start
Setting
Control panel
Administrative Tools
Services
2-2
point the cursor to each and confirm with ENTER to enter the property configuration dialogue.
Select Startup Type Automatic in the dialogue box that appears and confirm with OK
2-3
2-4
Computer Name
Any univocal name identifying the CNC in the
network
Workgroup
The identification of the PCs in the network
Domain
This option is normally exploited in large
networks and requires the presence and skills of
a system administrator for configuration.
The next step consists in configuring the transmission protocol. TCP/IP (Transmission Control
Protocol/Internet Protocol) is the set of the most common protocols and services used in network
system communications.
2-5
Click Properties.
2-6
2-7
Firstly, specify an IP address and a subnet mask which univocally identifies the NC on the network; this
data must be supplied by the administrator of the network to which you are connecting.
In the case of small networks not connected to the Internet, the IP address can be in range from
192.168.10.1 to 192.168.10.254 with subnet mask 255.255.255.0. Typically, the first three numbers of
the address will be the same and the fourth number will be used for univocal identification.
When a DHCP server is present in the network, you can select the "Obtain an IP address via DHCP"
option to obtain the connection address directly from the server.
The Gateway typically has to be configured only in large networks.
These procedures require specific technical knowledge and are not included in this manual.
WARNING: Do not delete or edit any other protocols which may be present in addition to
TCP/IP.
Press OK" to confirm selections.
You will be prompted to reboot the system. If the CNC software does not boot up correctly, shut the
system down again and switch the machine tool off by operating the master switch. The problem will
be solved at the next boot up.
Having ended the procedure, the CNC (with user privileges) can access the network server resources
and share the part program folder with other PCs (after setting up file share). See the following
paragraphs for details.
2-8
Point to the D:\S4000\PartProg directory, either right-click the mouse or press Application key (on the
keyboard between the left Windows logo key and the CTRL key). Select Sharing.. in the pop-up
that appears. (See figure below)
2-9
To specify:
Connect as: UtenteFinale
Password:
Selca
You can now connect to the previously shared folder for up and downloading part programs.
You can create a new CNC S4000 user corresponding to the users employed to access the server to
avoid entering the data above each time (see NETWORK ACCESS AUTHORIZATIONS below).
WARNING!
DO NOT CHANGE THE DEFAULT USER SET UP ON THE SELCA CNC. DO NOT
DELETE OR EDIT EXISTING USERS. SIMPLY ADD THE NEW USERS YOU REQUIRE.
The CNC may malfunction or be blocked if the data above is altered. A technical service
intervention may be required to restore original conditions.
2-10
Select Map Network Drive and the following window will appear:
Click on Browser and select the work group, the computer and the folder to be mapped:
2-12
Verify that Reconnect at Logon is available so that the resource connection will be re-established the
next time the system is booted up. In order to do so, the server must be on and the previously mapped
folder still available.
Press Finish to confirm.
At the end of this operation, the new network disk will appear:
After completing the operations above, a new disk will appear in the CNC edit environment dialog
(identified by the previous selected letter). This corresponds to the mapped folder where to transfer the
required program files (see figure below).
Note: Mapped disks cannot be seen in the "Machine tool" running environment for safety reasons. This
is because programs cannot be run directly from the network. Program must be copied to local
system in order to be run.
2-13
2-14
The KILLALL.BAT program will be started. Repeat the operation for at least three times in a row. This
program will kill all CNC software modules. It must be started several times because the various
modules have different time sequences which must be followed in order to be correctly shut down.
Select Services
3-1
3-2
Select Startup Type Automatic in the dialogue box that appears and confirm with OK
Go back to the service window and select HW profile for the activated services. Check that status is
enable. If not, select Enabled with the right button.
3-3
The next step consists in configuring the transmission protocol. TCP/IP (Transmission Control
Protocol/Internet Protocol) is the set of the most common protocols and services used in network
system communications.
TCP/IP is normally installed on S4000 system. Proceed as follows to configure:
Click Protocols:
3-4
Firstly, specify an IP address and a subnet mask which univocally identifies the NC on the network; this
data must be supplied by the administrator of the network to which you are connecting.
In the case of small networks not connected to the Internet, the IP address can be in range from
192.168.10.1 to 192.168.10.254 with subnet mask 255.255.255.0. Typically, the first three numbers of
the address will be the same and the fourth number will be used for univocal identification.
When a DHCP server is present in the network, you can select the "Obtain an IP address via DHCP"
option to obtain the connection address directly from the server.
The Gateway typically has to be configured only in large networks.
These procedures require specific technical knowledge and are not included in this manual.
WARNING: Do not delete or edit any other protocols which may be present in addition to
TCP/IP.
Press OK" to confirm selections.
You will be prompted to reboot the system. If the CNC software does not boot up correctly, shut the
system down again and switch the machine tool off by operating the master switch. The problem will
be solved at the next boot up.
Having ended the procedure, the CNC (with user privileges) can access the network server resources
and share the part program folder with other PCs (after setting up file share). See the following
paragraphs for details.
3-5
3-6
To specify:
Connect as UtenteFinale
Password
Selca
You can now connect to the previously shared folder for up and downloading part programs.
You can create a new CNC S4000 user corresponding to the users employed to access the server to
avoid entering the data above each time (see NETWORK ACCESS AUTHORIZATIONS below).
WARNING!
DO NOT CHANGE THE DEFAULT USER SET UP ON THE SELCA CNC. DO NOT
DELETE OR EDIT EXISTING USERS. SIMPLY ADD THE NEW USERS YOU REQUIRE.
The CNC may malfunction or be blocked if the data above is altered. A technical
service intervention may be required to restore original conditions.
3-7
Select the name of the drive to be associated to the folder to be mapped (typically confirm the
prompted name).
Select Reconnect at Logon so that the resource connection will be re-established the next time the
system is booted up. In order to do so, the server must be on and the previously mapped folder still
available.
Press "OK" to confirm.
3-8
After completing the operations above, a new disk will appear in the CNC edit environment dialog
(identified by the previous selected letter). This corresponds to the mapped folder where to transfer the
required program files (see figure below).
Note: Mapped disks cannot be seen in the "Machine tool" running environment for safety reasons.
This is because programs cannot be run directly from the network. Program must be copied to local
system in order to be run.
3-9
3-10
4.1
These operating systems do not have particular security levels. No user recognition is used to access
the system and the folders are immediately accessible.
User Name:
UtenteFinale
Password:
Selca
Specifically, you will need to create a new user corresponding to the SELCA CNC on the server to map
a network disk on a server in these operating systems. THESE ACTIVITIES MUST BE CARRIED OUT
BY THE SYSTEM ADMINISTRATOR.
WARNING:
The password and user name are case-sensitive. Remember to note upper and lower
case characters.
4-1
Start
Program,
Administrative tools (common)
User Manager
On the menubar select User and New User to create the new user, the following window will
appear.
4-2
Compile the fields UserName and Password as described above and select User Cannot Change
Password and Password Never Expires.
4-3
4-4
Compile the fields UserName and Password as described above and select User cannot change
password and Password never expired and Create and then Close.
4-5
4-6
5. TROUBLESHOOTING
FUNCTIONAL CONNECTION TESTS
The TCP/IP protocol must be correctly configured to test connections regardless of authorizations on
user level. Use the Ping diagnostic command to call a server IP address.
You can check if the connection and protocol are correctly configured and running according to the
reply.
To run the Ping command: open MS-DOS Prompt on the CNC (Start, Programs, Command
prompt) and enter the Ping command followed by the server IP address.
Example:
C:\>ping 172.18.6.67 and press Enter to confirm.
5-1
In addition to the previous checks made through the PING command, the currently manufactured (only
with Windows NT) S404x CNCs are equipped with Intel PRO100+ network board, that provides other
diagnostic tools.
To proceed, point to Network neighborhood on the Windows desktop and press Application (located
on the keyboard to the right of the spacebar between the Windows logo key and the CTRL key).
Select Properties and Adapters in the pop-up menu that appears.
Point to the Intel PRO/100+ network board and then click on Properties.
5-2
10/100 Mps:
connection speed.
Activity:
Full duplex:
5-3
5-4