Vous êtes sur la page 1sur 15

count

ITEM

DESCRIPTION

UNIT

Total Quantity

Rate

Cost

Bill No. 05: Culverts


5.01

Earthworks in excavation for foundation for structures complete


with all lifts and lead upto 1 Jm complete as per drawing, technical
specification sections 300 and 2900 and as directed by Engineer.

In all type of strata excluding Hard rock.

In Hard rock by any method including blasting, as approved by


Engineer.
Providing and laying Plain cement concrete in open foundation
and below foundation of culverts complete as per
drawing,Technical Specification Sections 1500, 1700 and 2100
and as directed by Engineer.

5.02

cum

49,937

cum.

PCC Grade M 15 for levelling course.

cum.

5,133

PCC Grade M15 for curtain wall

cum.

3,225

5.03

a
b
c
d
5.03

a
b
c
d
5.03

a
b
c
d
5.04

a
b
c
5.05

Providing and laying Reinforced Cement Concrete in Foundation,


mechanically mixed and compacted, including centering and
shuttering but excluding cost of reinforcement, all complete as per
drawings and Technical specifications and as directed by the
Engineer-in-charge.
RCC Grade M20 for Foundation
RCC Grade M25 for Foundation
RCC Grade M30 for Foundation
RCC Grade M35 for Foundation

cum.
cum.
cum.
cum.

1,293
-

Providing and laying Reinforced cement concrete in sub-structure,


mechanically mixed and compacted, including centering and
shuttering but excluding cost of reinforcement, all complete as per
drawings and Technical specifications and as directed by the
Engineer-in-charge.

PCC Grade M20 for Substructure (Head Wall)


RCC Grade M25 for Substructure
RCC Grade M30 for Substructure
RCC Grade M35 for Substructure
Providing and laying Reinforced cement concrete in sub-structure,
mechanically mixed and compacted, including centering and
shuttering but excluding cost of reinforcement, all complete as per
drawings and Technical specifications and as directed by the
Engineer-in-charge.

cum.
cum.
cum.
cum.

3,934
9,307
1,890
-

RCC Grade M20 for Superstructure


RCC Grade M25 for Superstructure
RCC Grade M30 for Superstructure
RCC Grade M35 for Superstructure

cum.
cum.
cum.

8
425

cum.

Supplying, fitting and placing HYSD(TMT, Fe 500 grade)


reinforcement in foundation, sub-structure and super-structure
complete as per drawing, Technical Specification Section 1600
and as directed by Engineer.
For Foundation
For Substructure
For Superstructure
Providing and Laying Reinforced cement concrete pipe NP4 pipe
on first class bedding of granular bedding material (including cost
of bedding) in single row / multi rows including fixing collar with
cement, mortar 1:2 (but excluding excavation, protection

5.05 (a) Dia 900mm (internal)


5.05 (b) Dia 1000mm (internal)
5.05 (c) Dia 1200mm (internal)

MT
MT
MT

116
833
5

1,087

2,341

371

No.

424

5.07 (d) Dia 1500mm (internal)


5.07 (e) Dia 1600mm (internal)
5.06

Gifford India Pvt. Ltd.

Providing and laying Drainage Spouts complete as per drawing,


Technical Specification Section 2700 and as directed by Engineer.

1 of 15

PASTED TOTAL QUANTITY

5.07

5.08

5.09

5.10

5.11

5.12

Gifford India Pvt. Ltd.

PCC M15 Grade leveling course below approach slab complete


as per drawing and Technical specification
Providing and laying Reinforced cement concrete M 30 Grade
approach slab including cost of reinforcement (HYSD TMT Fe500)
complete as per drawing, Technical Specification Sections 1500,
1600, 1700 and 2700 and as directed by Engineer.

cum.

cum.

Providing weep holes in masonry/Plain/Reinforced concrete


abutment, wing wall/return wall with 100 mm dia AC pipe (Heavy
Duty), complete as per drawing, Technical Specification Section
2500 and as directed by Engineer.

No.

6,857

Providing and laying back fill with granular material behind


abutment, wing wall and return wall complete as per drawing,
Technical Specification Section 300 and as directed by Engineer.

cum.

14,605

cum.

10,671

sqm.

285

Providing and laying filter media complete as per drawing,


Technical Specification Section 2500 with thicJness not less than
600 mm behind abutment, wing wall and return wall and as
directed by Engineer.
Providing and fixing in position bituminous paper bearing for slabs
as per approved drawing and confirming to IS:1398 and as
directed by Engineer.

2 of 15

PASTED TOTAL QUANTITY

5.13

5.14

5.15

5.16

5.17

5.18

5.19

5.20

5.21

5.22

5.24

5.25

5.25

Providing & fixing 20 mm thick compressible fibre board in


expansion joint complete as per drawing, Technical Specification
Section 2600 and as directed by Engineer.

1,031

Providing and laying cast in situ/precast RCC railing of M30 Grade


including reinforcement, complete as per approved drawings,
Technical Specification Sections 1500, 1600, 1700 and 2700 and
as directed by Engineer including horizontal and vertical members

452

598

sqm.

4,285

cum.

606

cum.

2,564

Providing painting, figuring and numbering to culvert upto 6m.


Span complete with Synthetic Enamal Paint, two coats on new
worJ, complete as per Technical Specification Section 800 and as
approved by Engineer.

Per cm ht. per


letter

35,370

Providing and applying 2 coats of water based cement paint to


unplastered concrete surface after cleaning the surface of dirt,
dust, oil, grease, efflorescence and applying paint @ of 1 litre for
2 Sqm. complete as per Technical Specification Section

sqm.

1,442

cum.

7,883

cum.

4,128

cum.

cum.

639

Providing and laying Reinforced Cement Concrete Crash Barrier


at the edges of the road, approaches to bridge structures and
medians, constructed with M-40 grade concrete with HYSD (TMT
Fe500) reinforcement complete as per drawing, technical
specification
Providing and fixing 80 mm GI pipe rail on Crash barrier including
providing three or more coats of Epoxypaint of approved colour
maJe or quality over a coat of epoxy Primer complete as per
drawings, Technical Specification Section 1900 and as directed b

Providing and Laying in position 65 mm thick wearing course


consisting of 40 mm thick bituminous concrete with 25mm Mastic
Asphalt over decJ slab after applying prime coat complete as per
drawings, Technical Specification Section 2700 and as directed by
E
Providing and laying Filter material underneath pitching in slopes
complete as per drawing, Technical Specification Section 2500
and as directed by Engineer.
Providing and laying Stone Pitching on slopes laid over prepared
filter media including boulder apron laid dry in front of toe of
embanJment complete as per drawing, Technical Specification
Section 2500 and as directed by Engineer.

Providing and laying Rigid flooring 300 mm thick flat stone in


cement motar 1:3 over 150mm thick cement concrete M15 grade
including cost of providing and laying M15 cement concrete
complete as per drawing, Technical Specification Section 2500,
IRC: 89 an
Filling in Quadrate Slop Protection

Brick Masonary Parapet

Providing and laying boulders apron for protection against scour


with stone boulders weighing not less than 40 kg each complete
as per drawing and Technical specification.

Rehabilitation and Repairs


5.26

2.27

5.28

General cleaning, removal of debris and vegetable growth from


and around the bridge structure as per Technical Specifications
Clause 201
Providing, Patching of damaged concrete surface with polymer
concrete and curing compounds, initiator and promoter, available
in present formulations, to be applied as per instruction of
manufacturer complete as per drawing, Technical Specification
Sectio

sqm.

Repair of damaged structural parts with cement concrete

Dismentling
5.26 PCC/RCC M-20
5.27 RCC Slab
5.28 Dismentling of Pipe

Gifford India Pvt. Ltd.

sqm.

cum.

cum
cum
RM

3 of 15

9,715
9
420

PASTED TOTAL QUANTITY

Dismentling of Pipe and Slab Culverts


Item
No.
1

Description

No

Length

Width

Depth

152

6.0

0.8

3.00

25

4.5

0.8

3.00

152
25

8.0
3.0

0.4
0.4

0.6
0.6

Dismentling of Existing Structure in Stone


Masonary/PCC
A.

Haed Wall/Abutment
Pipe Culvert
Box Culvert
Parapet Wall
Pipe Culvert
Box Culvert

Unit

RCC Slab
Box Culvert

Dismentling of Pipe
A. All types Pipe
Pipe Culvert

Cum

cum

cum
25
6

2.5
3

0.5
12

0.3
1.5

RM
152

86

Total
4
A

Dismentling of Widen pipe culvert


Head Wall
Deduction for pipe
For Parapet Wall

Cum

69

Cum
Cum

69
69

7.8
7.8

Area

4.21

0.6

0.64
0.4

Total

Dismentling of Widen slab culvert


A
B

Wing Wall
Slab

Gifford India Pvt. Ltd.

Cum
Cum

4 of 15

17
17

3
2

Area
1

2.54
0.3

Dismentling

Estimated Qty.

2188.80
270.00
2458.80
291.84
18.00
309.84
9.38
324.00

333.38

13072.00

13072.00

2264.44
-43.90
129.17
2349.71

2349.71

129.71
10.2

Gifford India Pvt. Ltd.

5 of 15

Dismentling

Abstract of Culvert Quantities


ITEM

DESCRIPTION

count
UNIT

1
13.3
5 x 0.6

2
13.53
5 x 0.6

112.73

112.73

#REF!
Total Qty.

Rate

Amount

Bill No. 05: New culverts, Reconstruction and Repair of existing Culverts
5.01

Earthworks in excavation for foundation for structures complete


with all lifts and lead upto 1 Jm complete as per drawing, technical
specification sections 300 and 2900 and as directed by Engineer.

5.01 (a)
5.01 (b)

In all type of strata excluding Hard rock.


In Hard rock by any method including blasting, as approved by
Engineer.
Providing and laying Plain cement concrete in open foundation and
below foundation of culverts complete as per drawing,Technical
Specification Sections 1500, 1700 and 2100 and as directed by
Engineer.
PCC Grade M 15 for levelling course.

5.02

5.03

5.03(a)
5.03 (b)
5.03 (c)
5.03 (d)
5.03 (e)
5.04

5.04(a)
5.04 (b)
5.04 (c)
5.04 (d)
5.04 (e)
5.05

5.05(a)
5.05 (b)
5.05 (c)
5.05 (d)
5.05 (e)
5.06

Cum

Cum

PCC Grade M20 (Curtain Wall)


RCC Grade M20
RCC Grade M25
RCC Grade M30
RCC Grade M35
Providing and laying Plain/Reinforced cement concrete in substructure for all leads, lifts and height, for construction/
reconstruction/ repair to structures complete as per drawing,
Technical Specification Sections 1000, 1500, 1700, 2100, 2200,
2300 and 2900 and as directed by the Engineer including wing
/return wall, retaining walls, box return wall, Median wall, bottom,
top slab and walls of box structure, including new and
reconstruction of head walls for HPC and parapet:

Cum
Cum
Cum
Cum
Cum

PCC Grade M20 ( Head Wall )


RCC Grade M20
RCC Grade M25 ( BOX )
RCC Grade M30
RCC Grade M35
Providing and laying Plain/Reinforced cement concrete in
superstructure for all leads, lifts and height, for construction/
reconstruction/ repair to structures complete as per drawing,
Technical Specification Sections 1000, 1500, 1700, 2100, 2200,
2300 and 2900 and as directed by the Engineer including wing
/return wall, retaining walls, box return wall, Median wall, bottom,
top slab and walls of box structure, including new and
reconstruction of head walls for HPC and parapet:

Cum
Cum
Cum
Cum
Cum

PCC Grade M20


RCC Grade M20
RCC Grade M25
RCC Grade M30
RCC Grade M35
Supplying, fitting and placing HYSD(TMT, Fe 500 grade)
reinforcement in foundation, sub-structure and super-structure
complete as per drawing, Technical Specification Section 1600 and
as directed by Engineer.

Cum
Cum
Cum
Cum
Cum

For Foundation

MT

5.06 (b)

For Sub structure

MT

5.06 (c)

For Superstructure

MT

5.07 (a)

38.41

38.41

33.04

0.40

33.04

0.40

Providing and Laying Reinforced cement concrete pipe NP4 pipe


on first class bedding of granular bedding material (including cost
of bedding) in single row / multi rows including fixing collar with
cement, mortar 1:2 (but excluding excavation, protection worJ,
bacJ filling and worJs in head walls and parapet) complete as per
drawing, Technical Specification Section 2900 and as directed by
Engineer for new/widening of existing culverts.

Dia 600mm (internal)

225.46
-

Providing and laying Plain/Reinforced cement concrete in


foundation for all leads, lifts and height, for construction/
reconstruction/ repair to structures complete as per drawing,
Technical Specification Sections 1000, 1500, 1700, 2100, 2200,
2300 and 2900 and as directed by the Engineer including wing
/return wall, retaining walls, box return wall, Median wall, bottom,
top slab and walls of box structure, including new and
reconstruction of head walls for HPC and parapet:

5.06 (a)

5.07

Gifford India Pvt. Ltd.

Cum

105.50

6 of 15

105.50

76.82

66.08
-

0.80

211.00

Summary PIPE

5.07 (b)
5.07 (c)
5.07 (d)
5.07 (e)
5.08

5.09

5.10

5.11

5.12

5.13

5.14

Gifford India Pvt. Ltd.

m
m

Dia 1000mm (internal)


Dia 1200mm (internal)
Dia 1500mm (internal)
Dia 1600mm (internal)
Providing and laying Drainage Spouts complete as per drawing,
Technical Specification Section 2700 and as directed by Engineer.

No.

PCC M15 Grade leveling course below approach slab complete as


per drawing and Technical specification

Cum

Cum

No.

Providing and laying Reinforced cement concrete M 30 Grade


approach slab including cost of reinforcement (HYSD TMT Fe500)
complete as per drawing, Technical Specification Sections 1500,
1600, 1700 and 2700 and as directed by Engineer.

Providing weep holes in masonry/Plain/Reinforced concrete


abutment, wing wall/return wall with 100 mm dia AC pipe (Heavy
Duty), complete as per drawing, Technical Specification Section
2500 and as directed by Engineer.
Providing and laying back fill with granular material behind
abutment, wing wall and return wall complete as per drawing,
Technical Specification Section 300 and as directed by Engineer.

Providing and laying filter media complete as per drawing,


Technical Specification Section 2500 with thickness not less than
600 mm behind abutment, wing wall and return wall and as
directed by Engineer.
Providing and fixing in position bituminous paper bearing for slabs
as per approved drawing and confirming to IS:1398 and as
directed by Engineer.

Cum

39.88

39.88

79.76

Cum

Sqm

7 of 15

Summary PIPE

5.15

5.16

5.17

5.18

5.19

5.20

5.21

5.22

5.23

5.24

Providing & fixing 20 mm thick compressible fibre board in


expansion joint complete as per drawing, Technical Specification
Section 2600 and as directed by Engineer.
Providing and laying cast in situ/precast RCC railing of M30 Grade
including reinforcement, complete as per approved drawings,
Technical Specification Sections 1500, 1600, 1700 and 2700 and
as directed by Engineer including horizontal and vertical members
and railing post.
Providing and laying Reinforced Cement Concrete Crash Barrier
at the edges of the road, approaches to bridge structures and
medians, constructed with M-40 grade concrete with HYSD (TMT
Fe500) reinforcement complete as per drawing, technical
specification as per IRC: 5, IRC: 6, IRC: 21 and sections 1500,
1600, 1700 and 2700 and as directed by Engineer including cost of
reinforcement and expansion joints filled with pre-moulded asphalt
filler board, Jeyed to the structure.

Providing and fixing 80 mm GI pipe rail on Crash barrier including


providing three or more coats of Epoxypaint of approved colour
maJe or quality over a coat of epoxy Primer complete as per
drawings, Technical Specification Section 1900 and as directed by
Engineer.
Providing and Laying in position 65 mm thick wearing course
consisting of 40 mm thick bituminous concrete with 25mm Mastic
Asphalt over deck slab after applying prime coat complete as per
drawings, Technical Specification Section 2700 and as directed by
Engineer.
Providing and laying Filter material underneath pitching in slopes
complete as per drawing, Technical Specification Section 2500 and
as directed by Engineer.
Providing and laying Stone Pitching on slopes laid over prepared
filter media including boulder apron laid dry in front of toe of
embanJment complete as per drawing, Technical Specification
Section 2500 and as directed by Engineer.
Providing painting, figuring and numbering to culvert upto 6m.
Span complete with Synthetic Enamal Paint, two coats on new
worJ, complete as per Technical Specification Section 800 and as
approved by Engineer.
Providing and applying 2 coats of water based cement paint to
unplastered concrete surface after cleaning the surface of dirt,
dust, oil, grease, efflorescence and applying paint @ of 1 litre for
2 Sqm. complete as per Technical Specification Section 800,
Additional Technical Specification A-15 and as directed by the
Engineer.
Providing and laying Rigid flooring 300 mm thick flat stone in
cement motar 1:3 over 150mm thick cement concrete M15 grade
excluding cost of providing and laying M15 cement concrete
complete as per drawing, Technical Specification Section 2500,
IRC: 89 an

5.25

Filling with suitable soil in the Quadrant Slop underneath the


pitching and filter media.

5.26

Brick Masonary Parapet

5.27

Providing and laying boulders apron for protection against scour


with stone boulders weighing not less than 40 kg each complete as
per drawing and Technical specification.

Sqm

Cum

2.99

2.99

5.98

Cum

5.98

5.98

11.96

Per cm ht.
per letter

150.00

150.00

300.00

Sqm

0.00

0.00

Cum

Cum

Cum

Cum

6.47

Rehabilitation and Repairs


5.28

5.29

Gifford India Pvt. Ltd.

General cleaning, removal of debris and vegetable growth from


and around the structure as per Technical Specifications Clause
201
Repair of damaged concrete due to spalling, honey combing,
scaling, leaching and exposed reinforcement by epoxy concrete in
super/substructure as per Technical specification section 2800
along with bonding coat between new & old concrete.

5.30

Cleaning of Pipe Culvert

5.31

Providing 65 mm thick A.C wearing coat as per Technical


specifications

6.47

12.94

Sqm

Sqm

No.

Sqm

8 of 15

Summary PIPE

Gifford India Pvt. Ltd.

5.32

Repair of head wall/Wing wall

5.33

New Construction of Parapet & Repairing

Cum

Cum

9 of 15

Summary PIPE

Dismentling

Gifford India Pvt. Ltd.

5.34

PCC/RCC M-20

Cum

5.35

RCC Slab

Cum

5.36

Dismentling of Pipe

RM

10 of 15

Summary PIPE

W
N
R

Widening
New Construction
Reconstruction

SR. No.

1
2

10

11

12

Chainage

Existing
Length

Total
length

Proposed
Length

No of
Pipe

Dia of
Pipe

Thk.of
Pipe

No of
Head Wall

U/S
Apron

D/S
Apron

No. of
Toe Wall

No of CD
Structur
e

Remark

2
2

1
1

1
1

0
0

1
1

N
N

13.300
13.530

0
0

21.10
21.10

21.1
21.1

5
5

New Construction
0.6
0.06
0.6
0.06

DETAIL ESTIMATE OF PIPE CULVERTS


RCC PIPE CULVERT RECONSTRUCTION& NEW CONSTRUCTION ( 5 x 0.6 Mt. DIA)

Item No.
Description
1

for Pipe
For Appron
U/S
D/S
For Toe Wall

No

Length

Width

Depth

Estimated Qty.

Cum
Cum

2
1

8.540
18.45

2.4
5.7

1.1
0.52

45.09
54.69

Cum
Cum
Cum

1
1
0

Area =
Area =
3.61

6.36
15.21
0.6

0.6
0.6
0.75

3.82
9.13
0.00
112.73

112.73

3.38
51.48
-16.45
0.00
0.00
38.41

38.41

Earthwork in excavation
A. All types of Soil
For Head Wall

Total Qty for 1


No's Culverts

Unit

PCC M-15 Grade


For Head Wall base
For Pipe Base
Deduction for Pipe
PCC for Toe Wall
Toe Wall

Cum
Cum
Cum
Cum
Cum

2
1
5
0
0

8.040
19.040
19.040
3.61
3.61

1.40
5.20
Area=
0.50
0.20

0.15
0.52
0.173
0.15
0.50

PCC M-20 Grade


Head Wall

cum

Deduction for pipe


For Parapet Wall

cum

10

cum

HYSD Bar Reinforcement 4Kg Per Sqm

RCC Pipe NP-4


900 mm dia NP-4
1000 mm dia NP-4
600 mm dia NP-4

MT

M
M
M

7.84
(1.03+0.55)/
2
7.84

7.84

(1.25+0.40)/2
Area=
0.4

3.15

2.55

32.99

0.407

-3.71

0.6

3.76
33.04

33.04

0.40

0.40

0.00
0.00
105.50

0
0
105.5

21.10

Filter material

Cum

Area =

4.98

0.15

2.99

2.99

Pitching on slopes
a) Stone

Cum

Area =

4.98

0.30

5.98

5.98

Apron / flooring
a) Boulders
Appron
U/S
D/S

Cum
Cum

1
1

Area =
Area =

6.36
15.21

0.30
0.30

1.91
4.56
6.47

6.47

15

150.00

150

0.6

9.41

9.41

0.72
0.41

79.13
-39.25
39.88

39.88

Numbering of Culverts including painting


a)

Lettering (English & Roman)

10

Painting of concrete surface

11

Back filling
Deduction for Pipe

Gifford India Pvt. Ltd.

Per cm ht.
per letter

10

sqm

7.84

cum
cum
cum

1
5

19.28
19.28

12 of 15

5.7
Area =

PIPE 1

DETAIL ESTIMATE OF PIPE CULVERTS


RCC PIPE CULVERT RECONSTRUCTION& NEW CONSTRUCTION ( 5 x 0.6 Mt. DIA)

Item No.
Description
1

for Pipe
For Appron
U/S
D/S
For Toe Wall

No

Length

Width

Depth

Estimated Qty.

Cum
Cum

2
1

8.540
18.45

2.4
5.7

1.1
0.52

45.09
54.69

Cum
Cum
Cum

1
1
0

Area =
Area =
3.61

6.36
15.21
0.6

0.6
0.6
0.75

3.82
9.13
0.00
112.73

112.73

3.38
51.48
-16.45
0.00
0.00
38.41

38.41

Earthwork in excavation
A. All types of Soil
For Head Wall

Total Qty for 1


No's Culverts

Unit

PCC M-15 Grade


For Head Wall base
For Pipe Base
Deduction for Pipe
PCC for Toe Wall
Toe Wall

Cum
Cum
Cum
Cum
Cum

2
1
5
0
0

8.040
19.040
19.040
3.61
3.61

1.40
5.20
Area=
0.50
0.20

0.15
0.52
0.173
0.15
0.50

PCC M-20 Grade


Head Wall

cum

Deduction for pipe


For Parapet Wall

cum

10

cum

HYSD Bar Reinforcement 4Kg Per Sqm

RCC Pipe NP-4


900 mm dia NP-4
1000 mm dia NP-4
600 mm dia NP-4

MT

M
M
M

7.84
(1.03+0.55)/
2
7.84

7.84

(1.25+0.40)/2
Area=
0.4

3.15

2.55

32.99

0.407

-3.71

0.6

3.76
33.04

33.04

0.40

0.40

0.00
0.00
105.50

0
0
105.5

21.10

Filter material

Cum

Area =

4.98

0.15

2.99

2.99

Pitching on slopes
a) Stone

Cum

Area =

4.98

0.30

5.98

5.98

Apron / flooring
a) Boulders
Appron
U/S
D/S

Cum
Cum

1
1

Area =
Area =

6.36
15.21

0.30
0.30

1.91
4.56
6.47

6.47

15

150.00

150

0.6

9.41

9.41

0.72
0.41

79.13
-39.25
39.88

39.88

Numbering of Culverts including painting


a)

Lettering (English & Roman)

10

Painting of concrete surface

11

Back filling
Deduction for Pipe

Gifford India Pvt. Ltd.

Per cm ht.
per letter

10

sqm

7.84

cum
cum
cum

1
5

19.28
19.28

13 of 15

5.7
Area =

PIPE 2

Repair and Rehabilitation of Existing Culvert


box (55
no.s)
Item
No.

Description

Unit

Page Total
1x2.5

General cleaning, removal of debris and vegetable growth from and around the bridge structure as per Technical
Specifications Clause 201

m2

Repair of damaged structural parts with cement concrete (Parapet/Head Wall/Wing Wall etc.)

m3

Patching of damaged concrete surface

m2

495

495

31.68

32
0

Repair and Rehabilitation of Existing Culvert

Item
No.

Description

Slab

slab

slab

slab

1x3.6 (4
no.s)

1x3.5 (2
no.s)

1x3

1x2.4 (2 nos)

52

25

11

17

1.34

0.58

4.55

48

24

Slab

Slab

Slab

box

1x4.15

1x5.3

1x2.5

15

19

157

0.92

0.48

0.80

1.02

1.02

1.95

3.12

1.63

2.70

3.45

1.63

28

11

21

11

13

15

152

Unit

General cleaning, removal of debris and vegetable growth from and around the bridge structure as per Technical
Specifications Clause 201

m2

Repair of damaged structural parts with cement concrete (Parapet/Head Wall/Wing Wall etc.)

m3

Replacement of Wearing Coat

Repair of superstructure and substructure

Page Total
1x2.5

Vous aimerez peut-être aussi