1. Stop the engine and disconnect the connector (3) for the governor actuator. Connect the test
harness to the connector.
2. Place the backup switch in the AUT position.
3. Turn the engine start switch to the ON position. Do not start the engine. Select the sweep test
for the governor actuator.
4. Enter the service mode. Perform the device test according to "ENG SWEEP".
https://127.0.0.1:7443/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 19/10/2016
320C & 320C L Excavators PAB00001-UP (MACHINE) POWERED BY 3066 Engine... Pgina 8 de 8
Illustration 5
g00690421
5. Use a digital multimeter to measure the frequency of the speed command signal while the
system is in operation. See the above illustration. The duty cycle should be approximately 45%
to 90%. A low duty cycle means a low engine speed. A higher duty cycle means a high engine
speed. The pulse width is narrow at low speeds and the pulse width is wide at high speeds.
6. An abnormality is present when the pulse width is not correct. A failure may exist in the
harness, the governor actuator or the controller.
7. The speed of the engine will vary in synchronization with the reciprocating drive. If the
controller is operating properly, the engine speed will vary between the high idle and the low
idle. The governor actuator may be installed incorrectly or the governor actuator may not be
operating correctly, if the engine speed is not correct. Also, the engine may be operating
incorrectly.