Vous êtes sur la page 1sur 3

320C & 320C L Excavators PAB00001-UP (MACHINE) POWERED BY 3066 Engine...

Pgina 6 de 8

Illustration 1

g00778226

Governor Actuator For 312C


(1) Governor actuator
(2) Governor cables
(3) Connector

Illustration 2

g00778227

Governor Actuator For 315C


(1) Governor actuator
(2) Governor cables
(3) Connector

Illustration 3

g00778702

https://127.0.0.1:7443/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 19/10/2016

320C & 320C L Excavators PAB00001-UP (MACHINE) POWERED BY 3066 Engine... Pgina 7 de 8

Governor Actuator For 319C, 320C series and 322C


(1) Governor actuator
(2) Governor cables
(3) Connector

Illustration 4

g00986349

Governor Actuator for 321C


(1) Governor actuator
(2) Governor Cables

1. Stop the engine and disconnect the connector (3) for the governor actuator. Connect the test
harness to the connector.
2. Place the backup switch in the AUT position.
3. Turn the engine start switch to the ON position. Do not start the engine. Select the sweep test
for the governor actuator.
4. Enter the service mode. Perform the device test according to "ENG SWEEP".

https://127.0.0.1:7443/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 19/10/2016

320C & 320C L Excavators PAB00001-UP (MACHINE) POWERED BY 3066 Engine... Pgina 8 de 8

Illustration 5

g00690421

5. Use a digital multimeter to measure the frequency of the speed command signal while the
system is in operation. See the above illustration. The duty cycle should be approximately 45%
to 90%. A low duty cycle means a low engine speed. A higher duty cycle means a high engine
speed. The pulse width is narrow at low speeds and the pulse width is wide at high speeds.
6. An abnormality is present when the pulse width is not correct. A failure may exist in the
harness, the governor actuator or the controller.
7. The speed of the engine will vary in synchronization with the reciprocating drive. If the
controller is operating properly, the engine speed will vary between the high idle and the low
idle. The governor actuator may be installed incorrectly or the governor actuator may not be
operating correctly, if the engine speed is not correct. Also, the engine may be operating
incorrectly.
Copyright 1993 - 2016 Caterpillar Inc.

Wed Oct 19 20:14:19 UTC-0400 2016

Todos los derechos reservados.


Red privada para licenciados del SIS.

https://127.0.0.1:7443/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 19/10/2016