Round Heatsinks
Solution Name
Thetas-a
(C/W)*
Thermal
Wattage
(W)
Heatsink
Rise Over
Ambient
(C)
Diameter
(mm)
Height
(mm)
2.8
10
28
87
57
2.8
10
28
100
42
Spotlight 34W
2.6
10
26
87
57
2.6
10
26
95
39
2.6
10
26
87
46
Spotlight 36W
2.6
10
26
87
28
2.5
15
37
87
57
2.5
15
37
100
42
2.4
20
47
87
57
2.4
20
47
100
42
2.3
16
37
87
46
Spotlight 34W
2.3
16
37
87
57
2.3
16
37
95
39
Spotlight 47W
2.3
10
23
87
60
Round Heatsinks
Solution Name
Thetas-a
(C/W)*
Thermal
Wattage
(W)
Heatsink
Rise Over
Ambient
(C)
Diameter
(mm)
Height
(mm)
2.3
10
23
87
60
Spotlight 36W
2.3
16
37
87
28
2.2
22
49
87
46
Spotlight 34W
2.2
22
49
87
57
2.2
22
49
95
39
Spotlight 38W
2.1
10
22
100
57
Spotlight 36W
2.2
22
49
87
28
Spotlight 47W
18
36
87
60
18
36
87
60
Spotlight 38W
1.9
19
36
100
57
Spotlight 47W
1.9
26
49
87
60
1.9
26
49
87
60
Spotlight 38W
1.8
28
49
100
57
Spotlight 60W
1.6
18
29
118
42
1.6
18
29
118
42
Downlight 40W
1.5
17
25
118
42
Downlight 40W
1.4
27
37
118
42
Spotlight 60W
1.4
28
39
118
42
1.4
28
39
118
42
Downlight 40W
1.3
37
49
118
42
Spotlight 60W
1.3
38
48
118
42
1.3
38
48
118
42
Round Heatsinks
Thetas-a
(C/W)*
Thermal
Wattage
(W)
Heatsink
Rise Over
Ambient
(C)
Diameter
(mm)
Height
(mm)
Downlight 48W
1.2
22
26
138
42
1.2
22
26
138
42
Downlight 48W
1.2
32
37
138
42
1.2
32
37
138
40
Downlight 48W
1.2
42
48
138
40
1.2
42
48
138
40
Spotlight 70W
1.2
22
27
134
42
Spotlight 70W
1.1
32
36
134
42
Spotlight 70W
1.1
42
45
134
42
R186-70
0.85
20
17
186
70
R186-70
0.83
30
25
186
70
R186-70
0.81
40
33
186
70
R150-170 Heatsink
0.69
47
32
150
170
R150-170 Heatsink
0.66
62
41
150
170
R150-170 Heatsink
0.64
77
49
150
170
Solution Name
* Thermal resistance values are measured in free air without airflow obstructions. Thermal resistance is measured from the bottom
middle of the heat sink to ambient air, with a heat source at least 4.1cm2. Actual thermal performance may vary by application and
final product design should be tested to assure proper thermal performance.
Rectangular Heatsinks
Solution Name
Thetas-a
(C/W)*
Thermal
Wattage
(W)
Heatsink
Rise Over
Ambient
(C)
Length
(mm)
Width
(mm)
Height
(mm)
1.3
24
30
144
112
42
1.2
34
40
144
112
42
1.2
24
30
144
112
47
1.2
34
39
144
112
47
1.1
44
49
144
112
42
1.1
44
49
144
112
47
0.74
45
33
100
180
70
0.69
60
41
100
180
70
0.66
75
50
100
180
70
0.58
55
32
100
270
70
0.54
75
41
100
270
70
0.52
90
49
100
270
70
* Thermal resistance values are measured in free air without airflow obstructions. Thermal resistance is measured from the bottom
middle of the heat sink to ambient air, with a heat source at least 15cm2. Actual thermal performance may vary by application and
final product design should be tested to assure proper thermal performance.
Thetas-a
(C/W)*
Acoustics
(dBA)
Diameter
(mm)
Height (mm)
3.3
16
51
59
2.7
19
51
59
2.5
18
66
40
2.3
18
75
68
30
51
59
22
66
40
1.8
22
75
68
1.7
28
66
40
1.7
18
75
46
1.6
18
95
46
1.6
18
95
46
1.4
22
75
46
1.4
28
75
68
1.3
28
75
46
1.3
22
95
46
1.3
22
95
46
1.2
22
75
77
1.17
19
87
82
1.1
25
75
77
1.1
18
118
57
1.03
19
87
46
28
95
46
22
87
77
28
95
46
19
100
58
Thetas-a
(C/W)*
Acoustics
(dBA)
Diameter
(mm)
Height (mm)
0.99
22
87
82
0.97
28
75
77
0.97
22
100
77
0.94
22
118
57
0.94
18
138
57
0.93
25
87
77
0.92
22
87
46
0.91
19
87
60
0.91
25
100
77
0.91
19
87
104
0.9
22
100
58
0.89
25
87
82
0.88
28
87
77
0.84
25
87
46
0.84
27
87
82
0.8
28
100
77
0.8
25
100
58
0.79
27
87
46
0.78
22
87
60
0.78
19
118
58
0.75
28
118
57
0.75
22
138
57
0.75
19
118
58
0.75
22
87
104
0.75
19
118
58
Solution Name
Thetas-a
(C/W)*
Acoustics
(dBA)
Diameter
(mm)
Height (mm)
0.7
25
87
60
0.7
28
100
58
0.66
25
87
104
0.66
22
118
58
0.66
27
87
60
0.65
22
118
58
0.65
22
118
58
0.64
27
87
104
0.63
28
138
57
0.63
19
134
58
0.63
19
134
58
0.6
25
118
58
0.6
25
118
58
0.59
22
134
58
0.59
22
134
58
R150-170 w/ 1 SynJet
0.59
18
150
170
0.58
25
118
58
0.55
28
118
58
0.55
28
118
58
R150-170 w/ 1 SynJet
0.53
22
150
170
0.52
25
134
58
0.52
25
134
58
0.52
28
118
58
R150-170 w/ 1 SynJet
0.48
27
150
170
0.46
28
134
58
Solution Name
Thetas-a
(C/W)*
Acoustics
(dBA)
Diameter
(mm)
Height (mm)
0.46
28
134
58
R150-170 w/ 2 SynJets
0.43
20
150
170
R150-170 w/ 2 SynJets
0.39
24
150
170
R150-170 w/ 3 SynJets
0.39
22
150
170
R150-170 w/ 2 SynJets
0.37
30
150
170
R150-170 w/ 3 SynJets
0.3
31
150
170
R150-170 w/ 3 SynJets
0.34
26
150
170
* Thermal resistance values are measured in free air without airflow obstructions. Thermal resistance is measured from the
bottom middle of the heat sink to ambient air measured at the inlet to the SynJet, with a heat source at least 4.1cm2. Actual
thermal performance may vary by application and final product design should be tested to assure proper thermal performance.
Thetas-a
(C/W)*
Acoustics
(dBA)
Length
(mm)
Width
(mm)
Height
(mm)
25
230
53
45
0.68
19
145
113
58
0.68
19
145
113
58
0.58
22
145
113
58
0.58
22
145
113
58
0.54
25
145
113
58
0.54
25
145
113
58
0.49
28
145
113
58
0.49
28
145
113
58
Indoor L100-180
(Single Heat Source 25cm2)
0.43
19
180
178
70
Outdoor L100-180
(Single Heat Source 25cm2)
0.43
19
180
178
70
Indoor L100-180
(2 Heat Sources 25cm2 / 1 Heat Source
75cm2)
0.41
19
180
178
70
Outdoor L100-180
(2 Heat Sources 25cm2 / 1 Heat Source
75cm2)
0.41
19
180
178
70
Thetas-a
(C/W)*
Acoustics
(dBA)
Length
(mm)
Width
(mm)
Height
(mm)
Indoor L100-180
(Single Heat Source 25cm2)
0.36
23
180
178
70
Outdoor L100-180
(Single Heat Source 25cm2)
0.36
23
180
178
70
Indoor L100-270
(Single Heat Source 25cm2)
0.34
21
270
178
70
Outdoor L100-270
(Single Heat Source 25cm2)
0.34
21
270
178
70
Indoor L100-180
(2 Heat Sources 25cm2 / 1 Heat Source
75cm2)
0.34
23
180
178
70
Outdoor L100-180
(2 Heat Sources 25cm2 / 1 Heat Source
75cm2)
0.34
23
180
178
70
Indoor L100-270
(3 Heat Sources 25cm2 / 1 Heat Source
75cm2)
0.30
21
270
178
70
Outdoor L100-270
(3 Heat Sources 25cm2 / 1 Heat Source
75cm2)
0.3
21
270
178
70
Indoor L100-180
(Single Heat Source 25cm2)
0.29
29
180
178
70
10
Outdoor L100-180
(Single Heat Source 25cm2)
0.29
29
180
178
70
Indoor L100-270
(Single Heat Source 25cm2)
0.28
25
270
178
70
Outdoor L100-270
(Single Heat Source 25cm2)
0.28
25
270
178
70
Indoor L100-180
(2 Heat Sources 25cm2 / 1 Heat Source
75cm2)
0.27
29
180
178
70
Thetas-a
(C/W)*
Acoustics
(dBA)
Length
(mm)
Width
(mm)
Height
(mm)
Outdoor L100-180
(2 Heat Sources 25cm2 / 1 Heat Source
75cm2)
0.27
29
180
178
70
Indoor L100-270
(Single Heat Source 25cm2)
0.25
30
270
178
70
Outdoor L100-270
(Single Heat Source 25cm2)
0.25
30
270
178
70
Indoor L100-270
(3 Heat Sources 25cm2 / 1 Heat Source
75cm2)
0.24
25
270
178
70
Outdoor L100-270
(3 Heat Sources 25cm2 / 1 Heat Source
75cm2)
0.24
25
270
178
70
Indoor L100-270
(3 Heat Sources 25cm2 / 1 Heat Source
75cm2)
0.21
30
270
178
70
Outdoor L100-270
(3 Heat Sources 25cm2 / 1 Heat Source
75cm2)
0.21
30
270
178
70
* Thermal resistance values are measured in free air without airflow obstructions. Thermal resistance is measured from the